SRF Cavity Emulator for PIP-II LLRF Lab and Field Testing

There are many stages in the LLRF and RF system development process for any new accelerator that can take advantage of hardware emulation of the high-power RF system and RF cavities. LLRF development, bench testing, control system development and testing of installed systems must happen well before SRF cavities are available for test. The PIP-II Linac has three frequencies of SRF cavities, 162.5 MHz, 325 MHz and 650 MHz and a simple analog emulator design has been chosen that can meet the cavity bandwidth requirements, provide tuning errors to emulate Lorentz force detuning and microphonics for all cavity types. This emulator design utilizes a quartz crystal with a bandwidth of 65Hz at an IF of ~ 4 MHz, providing a Q of ~ 1.3 x 10^7 at 650MHz. This paper will discuss the design and test results of this emulator.

43 PARTICLE ACCELERATORS↗

Mirror smooth superconducting RF cavities by mechanical polishing with minimal acid use

A new mechanical technique for polishing the inside surface of niobium superconducting RF (SRF) cavities has been developed. Mirror-like finishes, the smoothest observed in cavities so far, were produced after fine polishing, with < 15 nm RMS roughness over 1 mm2 scan area. This is an order of magnitude less than the typical roughness produced by electropolishing. The processing equipment has advantages of modest installed and operating costs, simple associated technology, and no large quantities of acutely toxic chemicals or special handling procedures. Cavity quality factors above 10 10 were maintained well above the 35 MV m-1 benchmark for electropolished cavities, and this was achieved with an intermediate finish not as smooth as the final polish. Repair of a weld defect, which is intrinsic to this process, was also demonstrated. These transformational aspects could enable a new SRF cavity processing paradigm for future large scale particle accelerators such as the International Linear Collider.

43 PARTICLE ACCELERATORS↗

Cavity Procurement and Qualification Plan for LCLS-II

The LCLS-II project aims to build 35 accelerating cryomodules, which are based on the European XFEL design but modified for operation in CW mode. Each cryomodule houses eight TESLA-style nine-cell superconducting radio-frequency cavities. The activities to assemble the first two prototype cryomodules are ongoing at FNAL and JLab. 264 cavities worth of cavities for the remaining 33 cryomodules will be procured from two industrial vendors in similar quantity considering the option to produce spares. The assembly of cavities into the production cryomodules will be distributed among FNAL (16 cryomodules) and JLab (17 cryomodules). In this paper the cavity procurement and qualification plan for the LCLS-II project is detailed.

Marhauser, F.↗

Trace gas detection with 2-photon, 2-color, cavity ring-down spectroscopy

In one aspect, a method of detecting a trace gas is disclosed. The method includes containing the trace gas in an optical cavity. The method further includes injecting a first laser light from a first laser into the optical cavity causing the trace gas to transition from an energy state lower that a first excited energy state to the first excited energy state, and injecting a second laser light from a second laser into the optical cavity causing the trace gas to transition from the first excited energy state to a second excited energy state. The method includes measuring, by a detector, a first cavity ringdown intensity as a function of time after turning off the second laser with the first laser on, and a second cavity ringdown intensity as a function of time after turning off the second laser with the first laser off.

McCartt, Daniel↗

Higher Order Modes Damping and Multipacting Analysis for the SPX Deflecting Cavity in APS Upgrade

A single-cell superconducting deflecting cavity operating at 2.815 GHz has been proposed and designed for the Short Pulse X-ray (SPX) project for the Advanced Photon Source (APS) upgrade. Each deflecting cavity is equipped with one fundamental power coupler (FPC), one lower order mode (LOM) coupler, and two higher order mode (HOM) couplers to achieve the stringent damping requirements for the unwanted modes. Using the electromagnetic simulation suite ACE3P, HOM damping will be calculated for the cavity including the full engineering design waveguide configurations and rf windows. Trapped modes in the bellows located in the beampipes connecting the cavities in a cryomodule will be computed and their effects on heating evaluated. Furthermore, multipacting activities at the end groups of the cavity will be identified to assess possible problems during high power processing.

Li, Z.↗

Compact Multicell Superconducting Crab Cavity for ILC

We propose a novel design of a crab cavity (CC) for the ILC project with low parasitic High Order Modes (HOM) losses and preserving the beam emittance, which is critical for operation with high beam current intensity. Multiple electrodes immersed in the hollow waveguide form a trapped-mode resonator. The transverse components of the electromagnetic field of the trapped dipole mode induce a transverse kick and efficiently deflect charged particles passing through the cavity. We present a scalable design of a superconducting Quasi-waveguide Multicell Resonator (QMiR) seamlessly connected with a beam vacuum chamber. The cavity is completely open at both ends, which significantly reduces the maximum loaded quality factor of the higher order modes (HOM), avoids complex HOM couplers, and thus simplifies the mechanical design of the cavity. The same port is used to feed RF power to the operating mode and to extract the same order modes (SOM). Finally, we estimate the expected cryogenic losses, HOM impedance limits, RF input power required, and frequency tuning for a QMiR cavity designed to operate at 2.6 GHz.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Update on the R&D of vertical buffered electropolishing on Nb samples and SRF single cell cavities

Electropolishing (EP) has become a popular choice as the final step of the surface removal process during the fabrication of Nb superconducting radio frequency (SRF) cavities. One of the major reasons for the choice is that Nb SRF cavities treated by EP tend to have a better chance to reach an accelerating gradient of 30 MV/m or higher than those treated by buffered chemical polishing (BCP). This advantage of EP over BCP can at least be partially attributed to the smoother Nb surfaces that EP can produce. Recently a Nb surface removal technique called buffered electropolishing (BEP) was developed at JLab. The root mean square of the Nb surfaces treated by BEP can be as smooth as 20nm over a surface area of 200X200 ?m2. In this contribution, R&D efforts of vertical BEP on Nb small flat samples and SRF single cell cavities since the last SRF conference in 2009 will be updated. It is shown that under a suitable condition, BEP can have a Nb removal rate as high as 10 ?m/mim that is more than 25 and 5 times quicker than those of EP and BCP(112) respectively. Possible mechanisms responsible for the high Nb removal rate are proposed. Clues on the optimization of vertical BEP and EP treatments on Nb SRF cavities from recent experimental results obtained on a Nb single cell demountable cavity will be discussed.

Wu, Andy↗

Modified 3+1/2 Cell SC Cavity Made of Large Grain Niobium for the FZD SRF Photoinjector

An SRF photoinjector has been successfully tested in FZD under the collaboration of BESSY, DESY, FZD, and MBI. In order to improve the gun cavity quality and thus reach a higher gradient, a new 3+1/2 superconducting cavity is being fabricated in cooperation with JLab. The modified cavity is made of large grain niobium, composed of one filter choke, one special designed half-cell (gun-cell) and three TESLA cavities. In this paper, the main updates of the new cavity design will be explained in detail. The deformation of the filter choke and the gun-cell, which is caused by pressure fluctuation in the He-line and also by the effect of the Lorentz force, will be minimized by stiffening between the filter choke and the gun-cell. Meanwhile, the cathode hole in the choke and gun-cell is enlarged for better rinsing. To simplify assembly, the NbTi pick-up will be welded directly on the wall of filter choke.

Murcek, P.↗

Analysis of Electronic Damping of Microphonics in Superconducting Cavities

In low current applications superconducting cavities have a high susceptibility to microphonics induced by external vibrations and pressure fluctuations. Due to the narrow bandwidth of the cavities, the amount of rf power required to stabilize the phase and amplitude of the cavity field is dictated by the amount of microphonics that need to be compensated. Electronic damping of microphonics is investigated as a method to reduce the level of microphonics and of the amount of rf power required. The current work presents a detailed analysis of electronic damping and of the residual cavity field amplitude and phase errors due to the fluctuations of cavity frequency and beam current.

Delayen, Jean↗

Preliminary Results from Multi-cell seamless niobium cavities fabricated by hydroforming

The technology of forming multi-cell seamless niobium cavities has been developed at DESY within the European CARE (Coordinated Accelerator Research in Europe) program. Three-cell units have been manufactured successfully and a 9-cell cavity has recently been completed from three sub-sections and has been successfully tested at DESY. Additionally, we have equipped two 3-cell units ? one center unit of a 9-cell cavity and one end-unit ? with niobium beam pipes, have tuned these units and carried out cryogenic radio-frequency (RF) tests after standard BCP surface treatments had been applied to these cavities. In addition, we have taken temperature maps with JLab?s two-cell thermometry system to compare with standard electron-beam welded cavities. This contribution will report about the preliminary cryogenic test results and the T-mapping ? this is an ongoing investigation.

Singer, X.↗

Electro-Mechanical Properties of Spoke-Loaded Superconducting Cavities

This paper presents experimental data characterizing the electro-mechanical properties of superconducting spoke-loaded cavities developed for high-intensity ion-linac applications, such as the cw ANL Advanced Exotic Beams Laboratory (AEBL) driver linac and the pulsed FNAL High Intensity Neutrino Source (HINS, now project X) proton driver linac. High-gradient cw operation at 4.2 K can produce violent boiling in the liquid helium coolant causing microphonic frequency noise. A spoke cavity designed to minimize the effects of helium pressure on RF eigenfrequency, the total microphonic induced RF frequency variations, were found to be on the level of the phase noise in the reference oscillator. To determine the pulsed cavity RF performance, the Lorentz transfer function was measured and used to predict the dynamic detuning in pulsed operation. There is good agreement between the predicted fit and the measured data, demonstrating the utility of the Lorentz transfer function, which can completely characterize the dynamics of the coupling between the mechanical cavity structure and the cavity RF field due to the Lorentz force.

Conway, Z.↗

Closed Loop Testing of Microphonics Algorithms Using a Cavity Emulator

An analog crystal filter based cavity emulator is modified with reverse biased varactor diodes to provide a tuning range of around 160 Hz. The piezo drive voltage of the resonance controller is used to detune the cavity through the bias voltage. A signal conditioning and summing circuit allows the introduction of microphonics disturbance from a signal source or using real microphonics data from cavity testing. This setup is used in closed loop with a cavity controller and resonance controller to study the effectiveness of resonance control algorithms suitable for superconducting cavities.

43 PARTICLE ACCELERATORS↗

Longitudinally joined superconducting resonating cavities

A system and method for fabricating accelerator cavities comprises forming at least two half cavities and joining the half cavities with a longitudinal seal. The half cavities can comprise at least one of aluminum, copper, tin, and copper alloys. The half cavities can be coated with a superconductor or combination of materials configured to form a superconductor coating.

Cooley, Lance↗

First Results from Two Nb3Sn Cavities Assembled in a CEBAF Quarter Cryomodule

Two 1.5 GHz CEBAF C75-shape 5-cell accelerator cavities were coated with Nb3Sn film using the vapor diffusion technique at Fermilab and Jefferson Lab coating facilities. Both cavities were measured at 4 K and 2 K in the vertical cavity test facility (VCTF) in each lab, then assembled into a CEBAF quarter cryomodule at Jefferson Lab. The cryomodule was tested at 4 K and 2 K in the CryoModule Test Facility (CMTF) at Jefferson Lab. RF test results for both cavities in the cryomodule are similar to those in the qualification test in VTS, with one cavity reaching Eacc = 7.9 MV/m and the other - 13.3 MV/m at 4 K.

Eremeev, G.↗

Cold Test Results of Pre-Production PIP-II SSR2 Cavities with High-Power Couplers in the Fermilab Spoke Test Cryostat

As part of the PIP-II project at Fermilab, a pre-production cryomodule featuring 325 MHz Single Spoke Resonator type 2 (SSR2) superconducting RF cavities is under construction. These SSR2 cavities are fabricated by industry partners and undergo initial cold testing at our collaborating institution, IJCLab in France, utilizing low-power coupler. Subsequently, the cavities are subjected to final qualification at Fermilab, complete with tuner and high-power coupler assemblies. This paper provides an overview of the ongoing efforts dedicated to high-power testing of jacketed SSR2 cavities in the Spoke Test Cryostat (STC) at Fermilab. Performance parameters obtained from these tests are presented, offering valuable insights into the cavities operational characteristics and readiness for integration into the PIP-II cryomodule.

43 PARTICLE ACCELERATORS↗

Fermilab experience of post-annealing losses in SRF niobium cavities due to furnace contamination and the ways to its mitigation: a pathway to processing simplification and quality factor improvement

We investigate the effect of high temperature treatments followed by only high-pressure water rinse (HPR) of superconducting radio frequency (SRF) niobium cavities. The objective is to provide a cost effective alternative to the typical cavity processing sequence, by eliminating the material removal step post furnace treatment while preserving or improving the RF performance. The studies have been conducted in the temperature range 800-1000C for different conditions of the starting substrate: large grain and fine grain, electro-polished (EP) and centrifugal barrel polished (CBP) to mirror finish. An interesting effect of the grain size on the performances is found. Cavity results and samples characterization show that furnace contaminants cause poor cavity performance, and a practical solution is found to prevent surface contamination. Extraordinary values of residual resistances ~ 1 nOhm and below are then consistently achieved for the contamination-free cavities. These results lead to a more cost-effective processing and improved RF performance, and, in conjunction with CBP, open a potential pathway to acid-free processing.

43 PARTICLE ACCELERATORS↗

Nb3Sn Superconducting Cavity Developments for Heavy-ion Beams

Nb3Sn has been identified as the most promising next-generation superconducting material for accelerator cavities. This is due to the higher critical temperature (Tc = 18 K) of Nb3Sn compared to niobium (Tc = 9.2 K), which leads to greatly reduced RF losses in the cavity during 4.5 K operation. This allows two important changes during cavity and cryomodule design. First, the higher Tc leads to negligible BCS losses when operated at 4.5 K, which allows for a higher frequency to be used, translating to significantly smaller cavities and cryomodules. Second, the reduced dissipated power lowers the required cryogenic cooling capacity, meaning that cavities can feasibly be operated on 5-10 W cryocoolers instead of a centralized helium refrigeration plant. These plants and distribution systems are costly and complex, requiring skilled technicians for operation and maintenance. These fundamental changes present an opportunity for a paradigm shift in how low-beta linacs are designed and operated. Fabrication and testing results of first prototypes are discussed.

Petersen, T. [Argonne]↗

Broad frequency tuning of a Nb$_{3}$Sn superconducting microwave cavity for dark matter searches

We demonstrate a novel broad-frequency tuning mechanism for superconducting microwave cavities designed for dark matter searches. Using a Nb$_3$Sn-coated cigar-shaped cavity operating at approximately 9 GHz, we achieve continuous frequency tuning exceeding 1 GHz by mechanically separating the two cavity halves: a "tuning-by-opening" technique. Finite-element method simulations predict that radiative losses do not degrade the quality factor even for large openings, as a closed cavity with an intrinsic quality factor of $10^7$ maintains this value for apertures up to 9 mm, corresponding to a tuning range from 9.0 to 7.5 GHz. Experimental validation using both copper ring spacers and a continuous sliding mechanism confirms $Q_0$ values exceeding the dark matter quality factor across the entire explored frequency range, despite mechanical imperfections and film non-uniformities. This tuning approach avoids inserting elements into the resonant volume, making it particularly suitable for high-Q superconducting cavities in axion haloscope experiments and readily applicable to REBCO-based implementations capable of operating in multi-tesla magnetic fields.

Maiello, D. [Padua U.; INFN, Padua] (ORCID:0009000↗