Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Balloon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Investigation of active regions at high resolution by balloon flights of the Solar Optical Universal Polarimeter (SOUP)

SOUP is a versatile, visible-light solar observatory, built for space or balloon flight. It is designed to study magnetic and velocity fields in the solar atmosphere with high spatial resolution and temporal uniformity, which cannot be achieved from the surface of the earth. The SOUP investigation is carried out by the Lockheed Palo Alto Research Laboratory, under contract to NASA's Marshall Space Flight Center. Co-investigators include staff members at a dozen observatories and universities in the U.S. and Europe. The primary objectives of the SOUP experiment are: to measure vector magnetic and velocity fields in the solar atmosphere with much better spatial resolution than can be achieved from the ground; to study the physical processes that store magnetic energy in active regions and the conditions that trigger its release; and to understand how magnetic flux emerges, evolves, combines, and disappears on spatial scales of 400 to 100,000 km. SOUP is designed to study intensity, magnetic, and velocity fields in the photosphere and low chromosphere with 0.5 arcsec resolution, free of atmospheric disturbances. The instrument includes: a 30 cm Cassegrain telescope; an active mirror for image stabilization; broadband film and TV cameras; a birefringent filter, tunable over 5100 to 6600 A with 0.05 A bandpass; a 35 mm film camera and a digital CCD camera behind the filter; and a high-speed digital image processor.

Tarbell, T.↗

A four channel He-3 cooled balloon-borne bolometer radiometer

A four channel He-3 cooled balloon-borne bolometer radiometer was constructed. The principal goal of the instrument is to measure the anisotropy of the 3 K cosmic background radiation on angular scales of 4 to 180 deg. The goal is to improve the sensitivity of the measurements to Delta T/T is less than .00001. A secondary goal is to survey the galactic thermal dust emission in the submillimeter range.

Meyer, Stephan↗

Three-meter balloon-borne telescope

The Three-Meter Balloon-Borne Telescope is planned as a general purpose facility for making far-infrared and submillimeter astronomical observations from the stratosphere. It will operate throughout the spectral range 30 microns to 1 millimeter which is largely obscurred from the ground. The design is an f/13.5 Cassegrain telescope with an f/1.33 3-meter primary mirror supported with a 3-axis gimbal and stabilization system. The overall structure is 8.0 m high by 5.5 m in width by 4.0 m in depth and weighs 2000 kg. This low weight is achieved through the use of an ultra lightweight primary mirror of composite construction. Pointing and stabilization are achieved with television monitoring of the star field, flex-pivot bearing supports, gyroscopes, and magnetically levitated reaction wheels. Two instruments will be carried on each flight; generally a photometric camera and a spectrometer. A 64-element bolometer array photometric camera operating from 30 to 300 microns is planned as part of the facility. Additional instruments will be derived from KAO and other development programs.

Hoffmann, William F.↗

Results of the 1989 NASA/JPL balloon flight solar cell calibration program

The 1989 solar cell calibration balloon flight was successfully completed on August 9, 1989, meeting all objectives of the program. Forty-two modules were carried to an altitude of 118,000 ft (36.0 km). The calibrated cells can now be used as reference standards in simulator testing of cells and arrays.

Anspaugh, B. E.↗

GPS-aided gravimetry at 30 km altitude from a balloon-borne platform

A balloon-borne experiment, flown at 30 km altitude over New Mexico, was used to test dynamic differential Global Positioning System (GPS) tracking in support of gravimetry at high-altitudes. The experiment package contained a gravimeter (Vibrating String Accelerometer), a full complement of inertial instruments, a TI-4100 GPS receiver and a radar transponder. The flight was supported by two GPS receivers on the ground near the flight path. From the 8 hour flight, about a forty minute period was selected for analysis. Differential GPS phase measurements were used to estimate changes in position over the sample time interval, or average velocity. In addition to average velocity, differential positions and numerical averages of acceleration were obtained in three components. Gravitational acceleration was estimated by correcting for accelerations due to translational motion, ignoring all rotational effects.

Lazarewicz, Andrew R.↗

Rotating-unbalanced-mass Devices for Scanning Balloon-borne Experiments, Free-flying Spacecraft, and Space Shuttle/space Station Experiments

A new method is presented for scanning balloon-borne experiments, free-flying spacecraft, and gimballed experiments mounted to the space shuttle or the space station. It uses rotating-unbalanced-mass (RUM) devices for generating circular, line, or raster scan patterns and an auxiliary control system for target acquisition, keeping the scan centered on the target, and producing complementary motion for raster scanning. It is ideal for applications where the only possible way to accomplish the required scan is to physically scan the entire experiment or spacecraft as in x ray and gamma ray experiments. In such cases, this new method should have advantages over prior methods in terms of either power, weight, cost, performance, stability, or a combination of these.

Polites, Michael E.↗

New spectral features of stratospheric trace gases identified from high-resolution infrared balloon-borne and laboratory spectra

A new Michelson-type interferometer system operating in the infrared at very high resolution has been used to record numerous balloon-borne solar absorption spectra of the stratosphere, ground-based solar absorption spectra, and laboratory spectra of molecules of atmospheric interest. In the present work results obtained for several important stratospheric trace gases, HNO3, CIONO2, HO2NO2, NO2, and COF2, in the 8- to 12-micron spectral region are reported. Many new features of these gases have been identified in the stratospheric spectra. Comparison of the new spectra with line-by-line simulations shows that previous spectral line parameters are often inadequate and that new analysis of high-resolution laboratory and atmospheric spectra and improved theoretical calculations will be required for many bands. Preliminary versions of several sets of improved line parameters under development are discussed.

Goldman, A.↗

Balloon-borne hard X-ray observations of SN 1987A

The region of the LMC containing SN 1987A was observed during a balloon flight of a hard-X-ray telescope on April 8-10, 1988. Significant continuum emission was detected in the 45-400-keV range and attributed to SN 1987A. Compared to an observation with the same instrument in October 1987, the source intensity decreased by about 50 percent, while the spectral shape remained qualitatively the same. This may represent the first clear indication that the hard-X-ray emission is entering the declining phase expected as the ejecta become optically thin to the Co-56 gamma rays.

Fishman, G. J.↗

In situ stratospheric measurements of HNO3 and HCl near 30 km using the balloon-borne laser in situ sensor tunable diode laser spectrometer

In situ stratospheric measurements of the concentrations of the reservoir species HNO3 and HCl made during two flights of the high-resolution (0.0005/cm) balloon-borne laser in situ sensor instrument from Palestine, Texas, are reported. A measured HNO3 volume mixing ratio of 4.3 parts per billion by volume (ppbv) at 31 km altitude is about 1 ppbv larger than previously reported measurements at 32 deg N. An HCl mixing ratio of 1.6 ppbv at 29 km is in agreement with values obtained from earlier remote sensing techniques within the experimental uncertainties. Upper limits at 31 km of 0.4 ppbv for H2O2 and 0.2 ppbv for HOCl are also derived from analyses of spectra recorded near 1252/cm.

May, R. D.↗

Vega balloon meteorological measurements

The Vega balloons obtained in situ measurements of pressure, temperature, vertical winds, cloud density, ambient illumination, and the frequency of lightning during their flights in the Venus middle cloud layer. The Vega measurements were used to develop a comprehensive description of the meteorology of the Venus middle cloud layer. The Vega measurements provide the following picture: large horizontal temperature gradients near the equator, vigorous convection, and weather conditions that can change dramatically on time scales as short as one hour.

Crisp, D.↗

Balloon borne in-situ detection of OH in the stratosphere from 37 to 23 km

The OH number density in the stratosphere has been measured over the altitude interval of 37 to 23 km at midday via a balloon-borne gondola launched from Palestine, Texas on July 6, 1988. OH radicals are detected with a laser-induced fluorescence instrument employing a 17-kHz-repetition-rate copper vapor laser-pumped dye laser optically coupled to an enclosed flow, in-situ sampling chamber. OH abundances ranged from 88 + or - 3l pptv in the 36 to 35 km interval to 0.9 + or - 0.8 pptv in the 24 to 23 km interval. The stated uncertainty includes that from both measurement precision and accuracy. Simultaneous detection of ozone and water vapor densities was carried out with separate on-board instruments.

Stimpfle, R. M.↗

The GRAD high-altitude balloon flight over Antarctica

The Gamma Ray Advanced Detector (GRAD) consists of a n-type germanium detector inside an active bismuth-germanate Compton and charged particle shield with additional active plastic shielding across the aperture. It will be flown on a high-altitude balloon at 36 km altitude at a latitude of 78 deg S over Antarctica for observations of gamma radiation emitted by the radioactive decay of Co-56 in the supernova SN1987A, for assessment of the performance of bismuth-germanate scintillation material in the radiation environment of near space, for gathering information on the gamma-ray background over Antarctica, and for testing fault-tolerant software.

Eichhorn, G.↗

Reconstruction of O3 and N2O fields from ER-2, DC-8, and balloon observations

Measurements of N2O and O3 during the Airborne Arctic Stratospheric Expedition have been composited using the potential vorticity and potential temperature of each measurement as coordinates. For ozone, data sources included the ER-2 and balloon ozonesonde in situ measurements, DC-8 DIAL lidar, and Stratospheric Aerosol and Gas Experiment satellite profiles. For N2O, only ER-2 data were used. These chemical composites have been reconstructed onto average meteorological fields for the mission in a latitude-altitude cross section, yielding a picture of the chemical composition of the polar vortex during this period. Tracers inside the vortex show an apparent descent of about 2 km relative to those outside, resulting in an apparent chemical edge on isentropic and isobaric surfaces.

Schoeberl, Mark R.↗

Ozone measurements from the Balloon Intercomparison Campaign

Measurements of the Balloon Intercomparison Campaign (BIC), conducted during fall, 1982 (BIC-1) and summer, 1983 (BIC-2), are reported. Results of five remote and two in situ techniques agree (with a few exceptions) within 95-percent confidence level uncertainties and generally within 15 percent above 20 km. Weighted mean profiles, which best represent conditions during the campaign, are used as a comparison standard. Accuracies of experiments indicated by BIC generally confirm estimated uncertainties for ECC sondes, UV photometry, and microwave emission experiments, are somewhat better for far-IR emission and IR absorption experiments, and are somewhat worse for IR emission and solar UV absorption experiments. The large collection of BIC measurements confirms a problem reported earlier with current theoretical modeling of ozone near 40 km.

Robbins, D.↗

Longitudinal variation of mid-latitude hiss from six long duration balloon flights

The longitudinal variation of midlatitude hiss as measured on six balloons at latitudes of 35-55 deg S, shows a significant minimum at 70-80 deg E, about 1000 km east of the geomagnetic conjugate of the Soviet transmitter UMS (17.1 kHz). It is suggested that the well documented pitch-angle diffusion induced by the UMS signal removes the ability of the trapped electrons to maintain the amplification of the hiss to at least the reflection and reducting losses (about 20 dB) at the ends of the echoing ducted path. The eastward shift of the minimum from the conjugate of UMS is primarily caused by the time taken by the eastward-drifting electrons to recover this ability, though the effect is enhanced by the east-west asymmetry in the propagation of hiss under the ionosphere.

Dowden, R. L.↗

Performance of bismuth germanate active shielding on a balloon flight over Antarctica

The GRAD (Gamma-Ray Advanced Detector) gamma-ray spectrometer was flown on a balloon at an altitude of 36.6 km over Antarctica on January 8-10, 1988, where it was used to make observations of SN 1987A. The performance of the bismuth germanate (BGO) active shielding in the near-space environment over Antarctica is examined. The promised effectiveness of this shielding in the suppression of unwanted background has been demonstrated. The BGO-shielded GRAD spectrometer detected gamma-ray lines with fluxes of 0.002/sq cm sec from SN 1987A in a radiation background approximately a factor of 4 more intense than that over Alice Springs, Australia. This level of sensitivity indicates that BGO is at least as effective as CsI when used as active shielding. Isomerism is common, both in the bismuth and germanium regions of the nuclear chart, but is found to be less of a problem for background suppression in the latter region than in the former.

Rester, A. C.↗

Analysis of tethered balloon, ceilometer and class sounding data taken on San Nicolas Island during the FIRE project

During the FIRE Marine Stratocumulus Program on San Nicolas Island, Colorado State University (CSU) and the British Meteorological Office (BMO) operated separate instrument packages on the NASA tethered balloon. The CSU package contained instrumentation for the measurement of temperature, pressure, humidity, cloud droplet concentration, and long and short wave radiation. Eight research flights, performed between July 7 and July 14, are summarized. An analysis priority to the July 7, 8 and 11 flights was assigned for the purposes of comparing the CSU and BMO data. Results are presented. In addition, CSU operated a laser ceilometer for the determination of cloud base, and a CLASS radiosonde site which launched 69 sondes. Data from all of the above systems are being analyzed.

Schubert, Wayne H.↗

Turbulence measurements using tethered balloon instrumentation during FIRE 1987

As part of the surface-based observations conducted on San Nicolas Island, the U.K. Meteorological Office operated a set of turbulence probes attached to a balloon tether cable. Typically six probes were used, each capable of measuring momentum, heat, and humidity fluxes. Two probes were fitted with net radiometers, one positioned above cloud and the other below; a third probe carried a Lyman-alpha hygrometer fitted with a pre-heater for the measurement of total water content. Some preliminary results are presented from the 14th July describing the variation in structure of the cloudy boundary layer during the daytime. This day was characterized by a complete cloud cover, an inversion height of approximately 600 m. and north-westerly winds of approximately 6 m.s(-1). As an illustration the equivalent potential temperature derived from a profile ascent made between approximately 0830 and 0930 (PDT) is shown. The data has been smoothed to a height resolution of about 4 metres. At this time the cloud base was approximately 200 m. and very light drizzle was reaching the surface. The vertical velocity variance and potential temperature flux for two periods are shown; the first (shown by full lines) immediately follows the profile and the second (shown by dashed lines) is central around 1400 (PDT). The data have been normalized by their maximum values in the first period. Cloud base has now risen to approximately 300 m. There is a marked variation during the morning, particularly in sigma w. The net radiative flux above cloud top has by now reached its maximum value.

Hignett, Phillip↗