Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Air Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Results of the Aerosol Sampling Experiment on the International Space Station

The indoor air quality of the International Space Station (ISS), in terms of particulate matter, has been assessed through a sampling experiment that collected airborne debris for return to Earth. The Aerosol Sampling Experiment took place on ISS in December 2016 and January 2017, with sample return in February 2017. For redundancy, two different aerosol samplers collected particles in two size ranges spanning from 10 nm to hundreds of micrometers. Multiple analysis techniques have been used to characterize the particles, such as reflective light microscopy, manual scanning electron microscopy (SEM) analysis (secondary and backscattered imaging) with energy dispersive spectroscopy (EDS) x-ray analysis, computer controlled scanning electron microscopy (CCSEM) and Raman spectroscopy. Sampling took place in five locations on ISS, with the greatest deposition of particles in Node 3, followed by Node 1, the US Lab and Node 2. The PMM had very few airborne particles, as expected, owing to the lack of human presence. A large proportion of the sampled material consisted of fibers from clothing. Many particles had complex morphologies or contained multiple metals in a carbonaceous matrix. Metal particles were analyzed for each sampling location in terms of both weight and number percent, with 27 heavy metals detected. Fiberglass and TiO2 particles were present in every location. Quantitative analysis results are presented, and where possible, particle emission sources are identified with the intention to fuel discussions on mitigation.

Meyer, Marit E.↗

Photocatalytic activity of ZnO nanoparticles with optimization of defects

Graphical abstract: Systematic scheme for photocatalytic activity. Pristine and air quenched ZnO nanoparticles were effectively synthesized by simple combustion method and effectively used as photocatalyst for photodegradtion of methyl orange dye. It was observed that air quenched ZnO nanoparticles shows the better properties as compared to pristine ZnO. The complete degradation of dye was observed in 150 min. - Highlights: • Pristine and air quenched ZnO nanoparticles were synthesized by simple combustion method. • Synthesized ZnO for air quenched ZnO has better optoelectronic properties. • ZnO nanoparticles for air quenched ZnO exhibiting complete photodegradation of Methyl Orange dye under UV irradiation. • Photocatalytic activities for all the samples were observed in 150 min. - Abstract: Tuning of defect levels is the major concern for the application of ZnO nanoparticles. These nanoparticles with different defect concentration were prepared by simple combustion method at 700 °C and subsequent quenching in air. The catalyst was characterized by X-Ray Diffraction (XRD), Field Emission Scanning Electron Microscope (FESEM), UV–vis spectroscopy measurements. XRD reveals that the cell volume increased with large temperature difference between 700 °C and quenched media. FTIR confirmed that the vibrational frequencies shifted from 519 cm{sup −1} to 535 cm{sup −1} point out the role of quenching defects. FESEM shows the size is of the order of 20–45 nm and found irregular distribution of grain boundaries in the quenched induced defects. Different morphology plays a major role in the enhancement of photocatalytic efficiency of synthesized nanoparticles. PL intensity indicates more oxygen vacancies for air quenched ZnO whereas; DTA study demonstrates that the synthesized ZnO is thermally stable. Kinetics study confirmed the photodegradation of methyl orange (MO) dye using this photocatalyst follows first order rate constant. It exhibits the complete degradation of dye only in 150 min under UV irradiation. Kinetic study revealed the rate constant of nanoparticles is 0.0165 min{sup −1}. Air quenched sample showed the higher intensity of defect band as compared to pristine ZnO.

36 MATERIALS SCIENCE↗

Tribochemical changes of alloy 800HT under sliding contact at elevated temperature in impure helium environment

This work investigates the chemical changes of the surface of Alloy 800HT during sliding contact under helium atmosphere in the presence of impurities at 750 °C, which is of interest for the nuclear industry. The alloy samples are exposed to helium (He) atmosphere at high temperature for long duration of 500 h to identify the chemical and topographical changes of the alloy surface. The oxidation rate constant is reported based on the weight change data. For the tribo-experimental samples, the surfaces inside and outside the wear track are studied thoroughly using techniques such as secondary electron microscopy, energy dispersive spectroscopy, x-ray diffraction, Raman spectroscopy and secondary ion mass spectroscopy. The formation and evolution of surface oxides are discussed in He atmosphere, compared with air. The presence of Fe-rich thin layer of oxide on top of a thicker Cr-rich oxide and a mixed spinel-based inner layer on the bulk is found. The persistent presence of thicker Fe3O4 in the wear track in high temperature air proved to be the reason of lower friction property. Pre-oxidation of the samples in air or He does not improve but worsen the tribological behavior in He atmosphere.

36 MATERIALS SCIENCE↗

Pacific Northwest National Laboratory Potential Impact Categories for Radiological Air Emissions Monitoring

In 2002, the EPA amended 40 CFR 61 Subpart H and 40 CFR 61 Appendix B Method 114 to include requirements from ANSI/HPS N13.1-1999 Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities for major emission points. Additionally, the WDOH amended the Washington Administrative Code (WAC) 246-247 Radiation protection-air emissions to include ANSI/HPS N13.1-1999 requirements for major and minor emission points when new permitting actions are approved. A result of the amended regulations is the requirement to prepare a written technical basis for the radiological air emission sampling and monitoring program. A key component of the technical basis is the Potential Impact Category (PIC) assigned to an emission point. This paper discusses the PIC assignments for the Pacific Northwest National Laboratory (PNNL) Integrated Laboratory emission units; this revision includes five PIC categories.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Navigating the Path to Autonomy: Real-World Lessons from an Air-Free Self-Driving Laboratory

While autonomous experimentation has promise to accelerate discovery in physcial sciences, the real-world integration of predictive models and experimentation is non-trivial. Here we describe the genesis of a self-driving laboratory (SDL) for air-sensitive chemistry at Argonne National Laboratory and demonstrate the experimental design considerations needed for high-throughput experiments before predictive models can lead to scientific discovery. Our SDL was designed to explore battery electrolyte stability. Our final SDL utilized plate readers in a glovebox with a nitrogen atmosphere to perform kinetic assays and screen hundreds of battery-relevant solvents. However, the roadmap to autonomy and airfree-friendly experimentation required the complex evaluation of several spectroscopic and chromatographic methods. The greatest experimental challenges were (a) developing long-term sampling methods that remained air-free; (b) accelerating kinetics to advance reactivity projections; and (c) ensuring labware compatibility with nonaqueous solvents used in battery chemistry. Our experiences highlight the practical gap between closed-loop aspirations and the realities of chemical discovery, offering lessons on the challenges of transferring every day laboratory workflows to autonomy. These results suggest a more realistic blueprint for autonomy in chemistry—one that balances thoughtful and realistic experimental formulation.

Robertson, Lily A.↗

Estimating Air Chemical Emissions from Research Activities Using Stack Measurement Data

Current methods of estimating air emissions from research and development (R&D) activities use a wide range of release fractions or emission factors with bases ranging from empirical to semi-empirical. Although considered conservative, the uncertainties and confidence levels of the existing methods have not been reported. Chemical emissions were estimated from sampling data taken from four research facilities over ten years. The approach was to use a Monte Carlo technique to create distributions of annual emission estimates for target compounds detected in source test samples. Distributions were created for each year and building sampled for compounds with sufficient detection frequency to qualify for the analysis. The results using the Monte Carlo technique without applying a filter to remove negative emission values showed almost all distributions spanning zero, and forty percent of the distributions having a negative mean. This indicates that emissions are so low as to be indistinguishable from building background. Application of a filter to allow only positive values in the distribution provided a more realistic value for emissions and increased the distribution mean by an average of sixteen percent. Release fractions were calculated by dividing the emission estimates by a building chemical inventory quantity. Two variations were used for this quantity: chemical usage, and chemical usage plus one-half standing inventory. Filters were applied so that only release fraction values from zero to one were included in the resulting distributions. Release fractions had a wide range among chemicals and among data sets for different buildings and/or years for a given chemical. Regressions of release fractions to molecular weight and vapor pressure showed weak correlations. Similarly, regressions of mean emissions to chemical usage, chemical inventory, molecular weight and vapor pressure also gave weak correlations. These results highlight the difficulties in estimating emissions from R&D facilities using chemical inventory data.

air chemical sampling, air emissions, research and↗

Errors of five-day mean surface wind and temperature conditions due to inadequate sampling

Surface meteorological reports of wind components, wind speed, air temperature, and sea-surface temperature from buoys located in equatorial and midlatitude regions are used in a simulation of random sampling to determine errors of the calculated means due to inadequate sampling. Subsampling the data with several different sample sizes leads to estimates of the accuracy of the subsampled means. The number N of random observations needed to compute mean winds with chosen accuracies of 0.5 (N sub 0.5) and 1.0 (N sub 1,0) m/s and mean air and sea surface temperatures with chosen accuracies of 0.1 (N sub 0.1) and 0.2 (N sub 0.2) C were calculated for each 5-day and 30-day period in the buoy datasets. Mean values of N for the various accuracies and datasets are given. A second-order polynomial relation is established between N and the variability of the data record. This relationship demonstrates that for the same accuracy, N increases as the variability of the data record increases. The relationship is also independent of the data source. Volunteer-observing ship data do not satisfy the recommended minimum number of observations for obtaining 0.5 m/s and 0.2 C accuracy for most locations. The effect of having remotely sensed data is discussed.

Legler, David M.↗

Pacific Northwest National Laboratory Potential Impact Categories for Radiological Air Emission Monitoring

In 2002, the EPA amended 40 CFR 61 Subpart H and 40 CFR 61 Appendix B Method 114 to include requirements from ANSI/HPS N13.1-1999 Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities for major emission points. Additionally, the WDOH amended the Washington Administrative Code (WAC) 246-247 Radiation protection-air emissions to include ANSI/HPS N13.1-1999 requirements for major and minor emission points when new permitting actions are approved. A result of the amended regulations is the requirement to prepare a written technical basis for the radiological air emission sampling and monitoring program. A key component of the technical basis is the Potential Impact Category (PIC) assigned to an emission point. This paper discusses the PIC assignments for the Pacific Northwest National Laboratory (PNNL) Integrated Laboratory emission units; this revision includes five PIC categories and clarifies the application of PIC 4 and PIC 5.

61 RADIATION PROTECTION AND DOSIMETRY↗

Ship Radar Observations of a Developing Hurricane in the East Pacific

During the recently completed East Pacific Investigation of Climate Processes in the Coupled Ocean-Atmosphere System (EPIC) field program, the NOAA research vessel Ronald H. Brown (RHB) was deployed in the east Pacific Inter Tropical Convergence Zone (ITCZ) for approximately 3 weeks near 10 deg. N, 95 deg. W. One of the principal objectives of the EPIC-ITCZ program was to observe the modulation of convection by synoptic-scale easterly waves and the air-sea coupling process in this poorly sampled region of the east Pacific. Data from the experiment will be used as validation to improve forecast models. The RHB carried a variety of platforms during EPIC to sample atmospheric and oceanic phenomena, including a scanning C-band Doppler radar, radiation flux instrumentation, air-sea flux system, Doppler lidar, 35 GHz cloud radar, UHF wind profiler, sea surface temperature (SST) sensors, as well as standard surface meteorological instrumentation and a suite of rain gauges. This presentation will focus on the analysis of C-band radar data that was collected on 10 September, 2001 as the ship passed through an easterly wave which later developed into hurricane Ivo. The ship captured approximately 12 hours of convection associated with the tropical disturbance. During this period, the domain sampled by the radar (approximately 71,000 sq km) contained a significant number of echo features. Specifically, the fraction of the domain containing radar echo above 10 dBZ reached 80% for over 2 hours and remained near 60% for a continuous six hour period. Animation of radar images showed distinct rotation in echo features associated with the easterly wave passage. Despite an approximate 4 C drop in surface air temperature and sustained winds approaching 20 m/ s, the SST remained nearly constant throughout the observation period (approx. 29.5 C). Peak values of latent and sensible heat flux exceeded 400 and 100 W /sq m, respectively. The radar documented the change in precipitation vertical structure as the ship passed through regions of significant convection with echo tops approaching 14 km and 30 dBZ echo tops extending to near 9 km embedded in regions that were predominantly stratiform in nature. Single Doppler retrievals (Extended Velocity Azimuth Display) were conducted continuously at 10-minute resolution for approximately 4 hours in the latter part of the observation period, and documented the transition from convection (low-level convergence, upper level divergence) to stratiform (mid-level convergence sandwiched between upper and lower level divergence) kinematic structure.

Cifelli, Robert↗

Characterization of microbial and chemical composition of shuttle wet waste with permanent gas and volatile organic compound analyses

Solid-waste treatment in space for Advanced Life Support, ALS, applications requires that the material can be safely processed and stored in a confined environment. Many solid-wastes are not stable because they are wet (40-90% moisture) and contain levels of soluble organic compounds that can contribute to the growth of undesirable microorganisms with concomitant production of noxious odors. In the absence of integrated Advanced Life Support systems on orbit, permanent gas, trace volatile organic and microbiological analyses were performed on crew refuse returned from the volume F "wet" trash of three consecutive Shuttle missions (STS-105, 109, and 110). These analyses were designed to characterize the short-term biological stability of the material and assess potential crew risks resulting from microbial decay processes during storage. Waste samples were collected post-orbiter landing and sorted into packaging material, food waste, toilet waste, and bulk liquid fractions deposited during flight in the volume F container. Aerobic and anaerobic microbial loads were determined in each fraction by cultivation on R2A and by acridine orange direct count (AODC). Dry and ash weights were performed to determine both water and organic content of the materials. Experiments to determine the aerobic and anaerobic biostability of refuse stored for varying periods of time were performed by on-line monitoring of CO2 and laboratory analysis for production of hydrogen sulfide and methane. Volatile organic compounds and permanent gases were analyzed using EPA Method TO15 by USEPA et al. [EPA Method TO15, The Determination of Volatile Organic Compounds (VOCs) in Ambient Air using SUMMA, Passivated Canister Sampling and Gas Chromatographic Analysis,1999] with gas chromatography/mass spectrometry and by gas chromatography with selective detectors. These baseline measures of waste stream content, labile organics, and microbial load in the volume F Shuttle trash provide data for waste subsystem analysis and atmospheric management within the ALS Project. Published by Elsevier Ltd on behalf of COSPAR.

NASA Center KSC↗

Adapting an Electron Microscopy Microheater for Correlated and Time-Resolved Ambient Pressure X-ray Photoelectron Spectroscopy

Environmental transmission electron microscopy (ETEM) can follow structural and chemical changes in nanomaterials under reaction conditions, including at temperatures up to 1300 °C and pressures up to ~20 mbar. However, ETEM studies are limited to localized areas of a sample and can benefit from correlative studies of a similar sample on larger length scales. Here, in this work, we describe the customization of a commercial microheater holder used in ETEM to anode-based ambient pressure X-ray photoelectron spectroscopy (APXPS), where chemical and electronic structure information is averaged over several hundred square micrometers. To benchmark heating capabilities in the APXPS instrument, core level binding energies were followed during surface chemical reactions of a Pd film, including CO adsorption–desorption, Pd oxidation, and PdO reduction. The fast heating feature of the microheaters advanced XPS experimental capabilities, including the collection of subsecond time-resolved spectra of the Pd 3d 5/2 peak during the reduction of an oxidized Pd film. The potential to use these heaters in a closed gas cell was also demonstrated by oxidizing Pd in a partial pressure of air locally dosed to the sample surface. General tips and considerations for the application of commercial ETEM heaters to any XPS system with a focused X-ray beam are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of Particle and Heat Losses from a High-Temperature Particle Receiver

High-temperature particle receivers are being pursued to enable next-generation concentrating solar thermal power (CSP) systems that can achieve higher temperatures (> 700 °C) to enable more efficient power cycles, lower overall system costs, and emerging CSP-based process-heat applications. The objective of this work was to develop characterization methods to quantify the particle and heat losses from the open aperture of the particle receiver. Novel camera- based imaging methods were developed and applied to both laboratory-scale and larger 1 MW t on-sun tests at the National Solar Thermal Test Facility in Albuquerque, New Mexico. Validation of the imaging methods was performed using gravimetric and calorimetric methods. In addition, conventional particle-sampling methods using volumetric particle-air samplers were applied to the on-sun tests to compare particle emission rates with regulatory standards for worker safety and pollution. Novel particle sampling methods using 3-D printed tipping buckets and tethered balloons were also developed and applied to the on-sun particle-receiver tests. Finally, models were developed to simulate the impact of particle size and wind on particle emissions and concentrations as a function of location. Results showed that particle emissions and concentrations were well below regulatory standards for worker safety and pollution. In addition, estimated particle temperatures and advective heat losses from the camera-based imaging methods correlated well with measured values during the on-sun tests.

14 SOLAR ENERGY↗

Effect of Air and Vacuum Storage on the Degradation of X-Ray-Exposed Aluminized-Teflon Investigated

Metalized Teflon FEP (fluorinated ethylene propylene, DuPont), a common thermal control material, has been found to degrade in the low-Earth-orbit space environment. The aluminized-FEP (Al-FEP) exterior layer on the Hubble Space Telescope has become extremely embrittled, with extensive cracking occurring on all sides of the telescope. This embrittlement has been primarily attributed to radiation exposure (x-rays from solar flares, electron/proton radiation, and possibly near-ultraviolet radiation) combined with thermal cycling. Limited samples of FEP tested after long-term exposure to low Earth orbit on the Hubble Space Telescope and on the Long Duration Exposure Facility indicated that there might be continued degradation in tensile properties over time. An investigation was conducted at the NASA Glenn Research Center to evaluate the effect of air and vacuum storage on the mechanical properties of x-ray-exposed FEP. Aluminized-FEP (5-mil-thick) tensile samples were x-ray exposed with 15.3-kV copper xrays for 2 hr, reducing the percent elongation to failure by approximately 50 percent in comparison to that for pristine Al-FEP. X-ray-exposed samples were stored in air or under vacuum for various time periods to see the effect of storage on tensile properties. Tensile results indicated that samples stored in air had larger decreases in tensile properties than samples stored under vacuum had, as seen in the graph. Samples stored under vacuum (for up to 400 hr) showed no further decrease in tensile properties over time, whereas samples stored in air (for up to 900 hr) appeared to show decreases in tensile properties over time. X-ray-exposed samples stored in air developed a hazy appearance in the exposed area, as seen in the photographs. When the source of the haziness was evaluated using scanning electron microscopy and atomic force microscopy, it was found to reside at the Al/FEP interface as witnessed by an increased surface roughness of the aluminized side of the material and a dramatic decrease in the adhesion between the Al and FEP. Optical properties of air-stored irradiated samples showed an increase in the diffuse reflectance, which is consistent with observed roughening that was characterized by AFM. These findings indicate that air exposure helps degrade x-ray-irradiated FEP. These results indicate that proper sample handling and storage is necessary with space-retrieved materials and with those exposed to ground-based irradiation simulation exposures.

deGroh, Kim K.↗

Wilson Corners SWMU 001 2019-2020 Annual Long-Term Monitoring Report Kennedy Space Center, Florida

This report presents a summary of the long-term monitoring (LTM) activities that occurred in 2019 and 2020 at Wilson Corners, Solid Waste Management Unit 001, at the John F. Kennedy Space Center (KSC), Florida. The site is monitored under KSC’s Resource Conservation and Recovery Act Corrective Action Program. Adaptive site management is being utilized through ongoing assessment, design, and interim measures. This approach also meets the requirements of Chapter 62-780, Florida Administrative Code. The goal of LTM at this site is threefold: to determine groundwater flow characteristics, monitor the downgradient concentration trends, and monitor select locations internal to the groundwater plume. Every 5 years, upgradient and side-gradient monitoring wells are sampled to verify delineation. The last time this was performed was in 2015. Sampling of these wells in 2020 was replaced with the direct push technology investigations in October 2020 and April 2021. The activities presented in this report include three field events: (1) December 2019 -groundwater gauging of 38 monitoring wells and sampling of 36 monitoring wells; (2) May 2020 - groundwater sampling of 7 monitoring wells; and (3) December 2020 - groundwater gauging of 49 monitoring wells and sampling of 43 monitoring wells. During the December 2019 and May 2020 events, monitoring wells were sampled using passive diffusion bags and were analyzed for a “full list” of volatile organic compounds (VOCs), including Freon 113. During the December 2020 event, the low flow sampling method was used, and samples were analyzed for a “select list” of VOCs, including Freon 113. The following conclusions can be made based on the 2019 and 2020 LTM results: •In December 2019 and December 2020, groundwater flow for the site was generally to the west with the individual zones only varying by occasional northerly and southerly components. This is generally consistent with historical observations at the site. •The GCTL plume continues to extend both horizontally and vertically beyond our current monitoring well network. •The vertical extent of VOCs was historically generally delineated by monitoring wells screened greater than 48 feet bls. The results from the two vertical extent monitoring wells WILC-MW0078 and WILC-MW0130 that were sampled during the 2019 and 2020 LTM indicate that groundwater VOC concentrations in both wells were greater than the GCTL. •Freon 113 was not detected above GCTLs during the 2019 and 2020 LTM events. Based on groundwater sampling activities performed during this reporting period, including recent DPT groundwater sampling conducted for the implementation of an air sparge system, the following recommendations are provided: •Install 10 new monitoring wells, which will be sampled along with 49 existing monitoring wells, to assist with delineation of the low concentration plume. The wells are listed inTable 4-1, and the proposed locations are presented on Figures4 -1 through 4-5. (Figures 4-1, 4-2, 4-3, and 4-5 also show updated plumes and proposed performance monitoring well locations. This information will be discussed and presented under a separate cover.) •Modify the annual LTM sampling plan as presented inTable 4-1. •Sampling for future events at the site will be conducted using low flow pumping methods. The next annual LTM sampling event is currently planned for December 2021. Please note the 10 new monitoring wells will not be installed before this event but will be installed as part of the upcoming IM construction and will be sampled during baseline sampling, along with the 49 existing monitoring wells. Following this sampling event, it is recommended that the Annual LTM be combined with the performance monitoring under the IM implementation, and LTM be temporarily discontinued. Objectives of the 2021 LTM are to: (i) evaluate groundwater gradient and flow direction by collecting depth to water measurements from LTM wells; (ii) continue monitoring the peripheral VOC trends in the northern, southern, and western portions of the site by monitoring existing wells and installing and monitoring new wells as recommended; and (iii) monitor select internal plume wells.

Jennifer Lynn Joyal↗

On the thermal oxidation of nuclear graphite relevant to high-temperature gas cooled reactors

Thermal oxidation of nuclear graphite components is highly undesirable because it can cause structural and property degradation that negatively affect a reactor's intended operation. In this work, the body of knowledge of nuclear graphite oxidation is highlighted, including when O 2 , H 2 O, and/or CO 2 are the oxidant. Oxidation conditions relevant to high-temperature gas-cooled reactors (i.e., when oxidation could occur either as an acute or chronic phenomenon) are emphasized. Here, the objective is to summarize graphite oxidation data in a practical and accessible way to inform future research and regulatory requirements. Although each grade of nuclear graphite is different, the oxidation mechanism has underlying commonalities. Although oxidation behavior is grade dependent, the general temperature dependence is well described by a sequence of elementary steps which become rate limiting. Because the regime transition temperature depends on sample microstructure, size, and oxidant supply rate, extrapolating results beyond the experimental range should be done cautiously. Gravimetric oxidation rate measurements generally replicate well. However, caution must be exercised when rates are estimated by other methods or for samples that deviate significantly in size. Air oxidation data for IG-110, NBG-18, and PCEA graphite is critically reviewed to emphasize this point. Despite the amount of experimental data, gaps remain. Sample size and shape effects are not fully explained. Data on the oxidant penetration depth are insufficient. Analytical assessments demonstrate that lower temperature oxidation does not necessarily imply that oxidation is uniform throughout the bulk. Oxidation occurs faster at higher temperature but is more localized to the exposed surface. Paradoxically, at equal mass loss percentage, low temperature oxidation leads to greater property degradation than at high temperature. The isolated effect of oxidation is important; however, a gap remains in the systematic understanding of any potential effect of neutron irradiation on graphite structure and reactivity.

36 MATERIALS SCIENCE↗

Use Of The Operational Air Quality Monitor (AQM) For In-Flight Water Testing Project

A primary requirement for manned spaceflight is Environmental Health which ensures air and water contaminants, acoustic profiles, microbial flora, and radiation exposures within the cabin are maintained to levels needed for crew health and for vehicle system functionality. The reliance on ground analyses of returned samples is a limitation in the current environmental monitoring strategy that will prevent future Exploration missions beyond low-Earth orbit. This proposal attempts to address this shortcoming by advancing in-flight analyses of water and air. Ground analysis of in-flight, air and water samples typically employ vapor-phase analysis by gas chromatography-mass spectrometry (GC-MS) to identify and quantify organic compounds present in the samples. We envision the use of newly-developed direct ionization approaches as the most viable avenue leading towards an integrated analytical platform for the monitoring of water, air, and, potentially bio-samples in the cabin environment. Development of an in-flight instrument capable of analyzing air and water samples would be the logical next step to meeting the environmental monitoring needs of Exploration missions. Currently, the Air Quality Monitor (AQM) on-board ISS provides this specific information for a number of target compounds in the air. However, there is a significant subset of common target compounds between air and water. Naturally, the following question arises, "Can the AQM be used for both air and water quality monitoring?" Previous directorate-level IR&D funding led to the development of a water sample introduction method for mass spectrometry using electrothermal vaporization (ETV). This project will focus on the integration of the ETV with a ground-based AQM. The capabilities of this integrated platform will be evaluated using a subset of toxicologically important compounds.

Macatangay, Ariel↗

A general methodology for inverse estimation of the elastic and anelastic properties of anisotropic open-cell porous materials—with application to a melamine foam

This paper proposes an inverse estimation method for the characterisation of the elastic and anelastic properties of the frame of anisotropic open-cell foams used for sound absorption. A model of viscoelasticity based on a fractional differential constitutive equation is used, leading to an augmented Hooke's law in the frequency domain, where the elastic and anelastic phenomena appear as distinctive terms in the stiffness matrix. The parameters of the model are nine orthotropic elastic moduli, three angles of orientation of the material principal directions and three parameters governing the anelastic frequency dependence. The inverse estimation consists in numerically fitting the model on a set of transfer functions extracted from a sample of material. The setup uses a seismic-mass measurement repeated in the three directions of space and is placed in a vacuum chamber in order to remove the air from the pores of the sample. The method allows to reconstruct the full frequency-dependent complex stiffness matrix of the frame of an anisotropic open-cell foam and in particular it provides the frequency of maximum energy dissipation by viscoelastic effects. The characterisation of a melamine foam sample is performed and the relation between the fractional-derivative model and other types of parameterisations of the augmented Hooke's law is discussed.

36 MATERIALS SCIENCE↗

Combined Experimental and Modeling Study of the Interactions of Acid Gas with Common Spacecraft Surfaces for Fire Safety Applications

A fire in a spacecraft poses detrimental consequences and risks mission success in addition to crew safety. This is compounded during long-duration missions when the crew has limited options to recover from a fire. A common spacecraft fire concern is the smoldering of wire insulation, typically made from Polyvinyl chloride (PVC) or Polytetrafluoroethylene (PTFE). This creates acid gases such as Hydrogen Chloride (HCl), Hydrogen Fluoride (HF) and Hydrogen Cyanide (HCN). These poisonous gases are hazardous to the crew. They also interact with common surfaces within the spacecraft more than dominant combustion products such as CO2 and H2O. This makes them more difficult to track for potential fire detection techniques, or for postfire clean-up. It is imperative to be able to understand and predict the fate of these poisonous species in a microgravity environment in order to design a safe vehicle. HCl interacts with a number of materials inside a spacecraft. Primary among these materials is aluminum, which is abundantly used due to its strong and light weight nature. Aluminum has a natural oxide layer that protects it from corrosion but is typically treated to enhance this oxide layer. Among these treatments is a chromate conversion coating (CCC), which provides a thin enough protective oxide layer to still conduct electricity, and a traditional anodized material that has a thicker oxide layer that does not conduct electricity. Nomex is another common material found inside a spacecraft. It is a flame-resistant woven polymer that is related to nylon. This commercially available material is used for cargo storage bags and as a fire barrier. Physics-based models were developed to predict the uptake of HCl by these materials. The ultimate objective of these models is to predict the fate of HCl within the spacecraft so that sensors can be placed in meaningful locations in future missions based on the model predictions. To support these modeling efforts, experiments were performed in a cast acrylic test cell that measured the difference between the inlet and outlet concentration of HCl after inserting a sample rod of the test material. Different uptake capacities were realized for each type of sample tested. A computational fluid dynamics model (CFD) model of the reactor was then constructed that used a one-step global reaction rate with calibratable reaction (or kinetic) constants. These constants were calibrated to match the HCl uptake on the CCC aluminum samples, and the same kinetic constants were then tested for the stock and anodized aluminum samples. Model predictions matched the experimental data for the stock aluminum, and to a much lesser extent, the anodized aluminum. The model was additionally validated at different flow rates, sample surface areas, and inlet concentrations, and showed good agreement for all stock and CCC samples. The model did not accurately predict the HCl uptake in the anodized samples compared to the other two types of aluminum. Adjusting the kinetic constants and transport properties did little to improve the prediction. X-Ray Photoelectron Spectroscopy (XPS) was used to determine that the oxide layer thickness of anodized aluminum is approximately 5,000 nm, compared to 250 nm for CCC and 50 nm for stock. XPS also revealed presence of chlorine further down in the aluminum oxide layer in anodized samples than CCC and stock samples after the samples were saturated with HCl, indicating that accounting for diffusion of HCl into the oxide layer is important for accurate prediction of HCl uptake onto anodized aluminum. Consequently, a multi-scale model was developed and tested. First, a single pore inside the anodized aluminum oxide layer was modeled and is referred to as the pore-scale model. In this model, HCl diffused through the pore and reacted with the aluminum oxide pore wall to create aluminum chloride. The sample was then saturated when the mass transfer resistance through the growing aluminum chloride layer became too large for the HCl to reach the aluminum oxide wall and continue the reaction. This pore-scale model was coupled to the reactor-scale model using a concentration-dependent diffusion coefficient, resulting in much more accurate predictions (approximately half the sum square error of the aforementioned reactor-scale model that produced good agreement for stock and CCC) for a variety of operating conditions. The amount of water vapor or relative humidity (RH) in the flow during a reactor experiment was determined to influence HCl uptake. Experiments were performed to understand the interaction of gaseous HCl with aluminum surfaces in the presence of water vapor. The results show that increasing levels of RH increased the capacity of aluminum to adsorb HCl but decreased the capacity of Nomex to uptake HCl. A series of tests were performed on individual aluminum samples after they had been saturated with a fixed concentration of HCl in dry air conditions with the goal of determining how their HCl uptake capacity changes after various treatments with water relative to the original saturation tests. HCl-saturated aluminum samples subjected to a second dry air flow at the same HCl concentration as the original test had an uptake of 23.5% of the original sample with no treatment in between. Saturated aluminum samples subjected to an air flow with a RH of 90% in between tests had an uptake of 35.6% of the original. Saturated aluminum samples submerged in distilled water for 12 hours in between tests had an uptake of 82.2% of the original sample. Previously saturated aluminum tested with HCl and a 50% RH air flow resulted in similar uptake characteristics in multiple repeated tests. The experiments show the profound effect water vapor has on HCl uptake onto aluminum surfaces. In the samples subjected to water vapor or liquid water, capillary condensation and capillary diffusion alters the transport of HCl significantly. A model was proposed that developed a relationship between RH and the coefficient of HCl diffusion in aluminum chloride. This produced an “S-shaped” curve with diffusion coefficient as a function of RH, with 45% RH represented as the point where the diffusion coefficient is halfway between no water saturation and 100% water saturation in the aluminum chloride product layer. No difference in uptake characteristics for the experiment or model were realized between 50% and 62% RH. The results from the large-scale microgravity experiment, Saffire, are discussed as they pertain to the fate of HCl throughout a spacecraft. HCl was released, both as a standalone event, and in concurrence with the burning of a structured cloth. These events only produced a small response in the far field HCl sensor, while a PMMA burn that did not produce HCl had a significantly greater response. A ground-based large-scale facility was constructed to flow acid gas at the scale and configuration realized in the Saffire experiments. A CFD model of this duct was constructed to test kinetic parameters developed in this work at a larger scale and different geometric configuration and to predict the results of the large-scale facility. The models developed in this work were used to interpret the results of the microgravity tests and lead the discussion on what further experiments and models are needed in order to predict the fate of acid gas in a spacecraft environment. To summarize, the major contributions of this work are as follows: the capacity to uptake HCl, with and without the presence of water vapor, was measured for a variety of real spacecraft surfaces. Several different models (single reactor-scale, multiscale, spacecraft-scale) were developed and with the aid of modeling, the rate of uptake for those surfaces was also predicted and validated. The kinetic parameters determined from the small-scale reactor experiments and models were used to predict large-scale and microgravity tests. Conclusions from this research will be used in the design of spacecraft vehicles and large-scale microgravity fire safety experiments. The models built by this work will aid designers in sensor placement and could be used to predict acid gas transport from fires in partial gravity, as would be seen in Lunar and Martian habitats.

fire safety↗