The dissipation and dispersion of small waves in arteries and veins with viscoelastic wall properties.
HF pressure waves dispersion in blood vessels ascribed to viscoelastic behavior of walls
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
HF pressure waves dispersion in blood vessels ascribed to viscoelastic behavior of walls
The developments are reported in physiological instrumentation, surgical procedures, measurement and data analysis techniques, and the definition of flight experiments to determine the effects of prolonged weightlessness on the cardiovascular system of subhuman primates. The development of an implantable telemetric data acquisition system is discussed along with cardiovascular research applications in renal hemodynamics. It is concluded that the implant technique permits a valid interpretation, free of emotional response, for the manipulated variable on physiological functions. It also allows a better definition of normal physiological baseline conditions.
A small mobile bed-side computer system is described that is capable of performing phonoangiographic analyses as well as many other common data analysis tasks in a hospital. The clinical application of phonoangiography is found to be greatly facilitated by the computer-provided availability of data acquisition and analysis capabilities.
Explore the source record for details and available documents.
Studies were made of (1) blood flow redistribution during lower body negative pressure (LBNP), (2) the profile of blood flow across the mitral annulus of the heart (both perpendicular and parallel to the commissures), (3) testing and evaluation of a number of pulsed Doppler systems, (4) acute calibration of perivascular Doppler transducers, (5) redesign of the mitral flow transducers to improve reliability and ease of construction, and (6) a frequency offset generator designed for use in distinguishing forward and reverse components of blood flow by producing frequencies above and below the offset frequency. Finally methodology was developed and initial results were obtained from a computer analysis of time-varying Doppler spectra.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A new system is described that delivers precise, stereotyped pressure changes to the human neck and elicits neurally-mediated heart rate changes. The centerpiece of this system is a Silastic chamber that is strapped to the anterior neck. This chamber is connected to a stepping-motor-controlled bellows assembly. A strain-gauge transducer measures the intensity of pressure changes. The entire system is controlled by microprocessors, and both stimuli and responses are displayed on a digital oscilloscope. The end-product of this system is a reproducible baroreceptor stimulus-cardiac response relation that can be recorded rapidly and safely in astronauts in space.
This videotape demonstrates the capabilities of the excimer laser and the angioscope for treating heart disease.
When astronauts return to Earth and stand upright, their heart rates may speed inordinately, their blood pressures may fall, and some returning astronauts may even faint. Since physiological adjustments to standing are mediated importantly by pressure-regulating reflexes (baroreflexes), we studied involuntary (or autonomic) nerve and blood pressure responses of astronauts to four, 15-second periods of 15- and 30-mmHg straining (Valsalva'.~ maneuver). We measured the electrocardiogram, finger blood pressure, respiration, and muscle sympathetic nerve activity in four healthy male astronauts before and during the 16-day Neurolab Space Shuttle mission. We found that although microgravity provoked major autonomic changes, no astronaut experienced fainting symptoms after the mission. Blood pressure fell more during straining in space than on Earth (the average reduction of systolic pressure with 30-mmHg straining was 49 mmHg during and 27 mmHg before the mission). However, the increases of muscle sympathetic nerve activity that were triggered by straining were also larger in space than on Earth. As a result, the gain of the sympathetic baroreflex, taken as the total sympathetic nerve response divided by the maximum pressure reduction during straining, was the same in space as on Earth. In contrast, heart rate changes, which are mediated by changes of vagus nerve activity, were smaller in space. This and earlier research suggest that exposure to microgravity augments blood pressure and sympathetic adjustments to Valsalva straining and differentially reduces vagal, but not sympathetic baroreflex responsiveness. The changes that we documented can be explained economically as a consequence of the blood volume reduction that occurs in space.
We assessed renal blood flow and pressor responses to graded angiotensin II doses in spontaneously hypertensive (SHR) and Wistar-Kyoto (WKY) rats ingesting a diet containing 1.6% sodium basally and after acute and chronic angiotensin converting enzyme (ACE) inhibition with captopril. In the basal state the pressor response to angiotensin II was enhanced (P<0.0005) and the renal vascular response was blunted (P<0.005) in SHR compared with WKY rats. After acute captopril administration the pressor response was enhanced in both strains, and the difference between them was maintained, while the renal vascular response was enhanced in both, but more in SHR, so that the renal vascular response in the SHR became larger than in WKY (P<0.0001). Chronic captopril treatment blunted both pressor and renal responses in WKY rats, but only the pressor response in SHR. The renal vessels of SHR seem to be different from those of WKY rats in reaction to exogenous angiotensin II, and in response to both acute administration of captopril (probably acting through blockade of angiotensin II production) and chronic administration of captopril (probably acting mainly through accumulation of kinin or production of prostaglandins).
No abstract available
An in vitro pulsatile pump flow system that is capable of producing physiologic pressures and flows in a mock circulatory system tuned to reproduce the first nine harmonics of the input impedance of a rhesus monkey was developed and tested. The system was created as a research tool for evaluating cardiovascular function and for the design, testing, and evaluation of electrical-mechanical cardiovascular models and chronically implanted sensors. The system possesses a computerized user interface for controlling a linear displacement pulsatile pump in a controlled flow loop format to emulate in vivo cardiovascular characteristics. Evaluation of the pump system consisted of comparing its aortic pressure and flow profiles with in vivo rhesus hemodynamic waveforms in the time and frequency domains. Comparison of aortic pressure and flow data between the pump system and in vivo data showed good agreement in the time and frequency domains, however, the pump system produced a larger pulse pressure. The pump system can be used for comparing cardiovascular parameters with predicted cardiovascular model values and for evaluating such items as vascular grafts, heart valves, biomaterials, and sensors. This article describes the development and evaluation of this feedback controlled cardiovascular dynamics simulation modeling system.
Cardiac electrical data are received from a patient, manipulated to determine various useful aspects of the ECG signal, and displayed and stored in a useful form using a computer. The computer monitor displays various useful information, and in particular graphically displays various permutations of reduced amplitude zones and kurtosis that increase the rapidity and accuracy of cardiac diagnoses. New criteria for reduced amplitude zones are defined that enhance the sensitivity and specificity for detecting cardiac abnormalities.
The visual impairment and intracranial pressure (VIIP) syndrome is a spaceflight-associated medical condition consisting of a constellation of symptoms affecting less than 70% of American astronauts who have flown International Space Station (ISS) missions. VIIP is defined primarily by visual acuity deficits and anatomical changes to eye structures and is hypothesized to be related to elevated intracranial pressure secondary to spaceflight-induced cephalad fluid shifts, although other space flight factors (e.g., diet, environmental factors) may contribute. Loss of visual acuity could be a significant threat to crew health and performance during and after an exploration mission and may have implications for years postflight.
The visual impairment and intracranial pressure (VIIP) syndrome is a spaceflight-associated set of symptoms affecting more than 50% of American astronauts who have flown International Space Station (ISS) missions. VIIP is defined primarily by visual acuity deficits and anatomical changes to eye structures (e.g. optic disc edema, choroidal folds, and globe flattening) and is hypothesized to be related to elevated intracranial pressure secondary to a cephalad fluid shift. However, ocular symptoms have not been replicated in subjects completing prolonged bed rest, a well-accepted spaceflight analog. Altered vascular compliance along with spaceflight factors such as diet, radiation exposure, or environmental factors may cause alterations in the cardiovascular system that contribute to the manifestation of ocular changes. Loss of visual acuity could be a significant threat to crew health and performance during and after an exploration mission and may have implications for years post-flight. The overall objective of this project is to determine if spaceflight alters vascular compliance and whether such an adaptation is related to the incidence of VIIP. This objective will be met by completing three separate but related projects.
The primary objective was to determine whether a high sodium diet during bed rest induced alterations in vascular compliance and was related to the incidence of VIIP. Ocular structural and functional measures and vascular ultrasound of the head and neck were acquired in bed rest subjects completing 10-14 days in 6deg head-down tilt.