Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AMPLIFIER DESIGN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

The Timepix4 analog front-end design: Lessons learnt on fundamental limits to noise and time resolution in highly segmented hybrid pixel detectors

This manuscript describes the optimization of the front-end readout electronics for high granularity hybrid pixel detectors. The theoretical study aims at minimizing the noise and jitter. The model presented here is validated with both circuit post layout simulations and measurements on the Timepix4 Application Specific Integrated Circuit (ASIC). The analog front-end circuit and the procedure to optimize the dimensions of the main transistors are described with detail. The Timepix4 is the most recent ASIC designed in the framework of the Medipix4 Collaboration. It was manufactured in 65nm CMOS process, and consists of a four side buttable matrix of 448 × 512 pixels with 55µm pitch. The analog front-end has a gain of ~36mV/ke - when configured in High Gain Mode, and ~20mV/ke - when configured in Low Gain Mode. The Equivalent Noise Charge (ENC) is ~68e - rms and ~80e - rms in High Gain Mode and in Low Gain Mode respectively. In event driven mode the incoming hits can be time stamped within a ~ 200ps time bin and the chip can deal with a maximum flux of ~ 3.6MHzmm –2 s –1 . In photon counting mode, the chip can deal with up to ~ 5GHzmm –2 s –1 . The routine designed to optimize the Timepix4 front-end is then used to analyze the performance limits in terms of jitter and noise for Charge Sensitive Amplifiers in pixel detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cracking in polymer substrates for flexible electronic devices and its mitigation

Mechanical reliability plays a critical role in determining the durability of flexible electronic devices because of the significant mechanical stresses they experience during manufacturing and operation. Many such devices are built on sheets comprising stiff transparent-conducting oxide (TCO) electrode films on compliant polymer substrates, and it is generally assumed that the high-toughness polymer substrates do not crack. Contrary to this assumption, here we show extensive cracking in the polymer substrates during bending of a variety of TCO/polymer sheets, and a device example — flexible perovskite solar cells. Such substrate cracking, which compromises the overall mechanical integrity of the entire device, is driven by the amplified stress-intensity factor caused by the elastic mismatch at the film/substrate interface. To mitigate this substrate cracking, an interlayer-engineering approach is designed and experimentally demonstrated. This approach is potentially applicable to myriad flexible electronic devices, with stiff films on compliant substrates, for improving their durability and reliability.

42 ENGINEERING↗

Observation of pulsed x-ray trains produced by laser-electron Compton scatterings

X-ray generation based on laser-electron Compton scattering is one attractive method to achieve a compact laboratory-sized high-brightness x-ray source. We have designed, built, and tested such a source; it combines a 50 MeV multibunch electron linac with a mode-locked 1064 nm laser stored and amplified in a Fabry-Perot optical cavity. We directly observed trains of pulsed x rays using a microchannel plate detector; the resultant yield was found to be 1.2x10{sup 5} Hz in good agreement with prediction. We believe that the result has demonstrated good feasibility of linac-based compact x-ray sources via laser-electron Compton scatterings.

43 PARTICLE ACCELERATORS↗

In-situ characterization of femtosecond laser-induced crystallization in borosilicate glass using time-resolved surface third-harmonic generation

Coherent phonon dynamics in condensed-phase medium are responsible for important material properties including thermal and electrical conductivities. We report a structural dynamics technique, time-resolved surface third-harmonic generation (TRSTHG) spectroscopy, to capture transient phonon propagation near the surface of polycrystalline CaF{sub 2} and amorphous borosilicate (BK7) glass. Our approach time-resolves the background-free, high-sensitivity third harmonic generation (THG) signal in between the two crossing near-IR pulses. Pronounced intensity quantum beats reveal the impulsively excited low-frequency Raman mode evolution on the femtosecond to picosecond timescale. After amplified laser irradiation, danburite-crystal-like structure units form at the glass surface. This versatile TRSTHG setup paves the way to mechanistically study and design advanced thermoelectrics and photovoltaics.

36 MATERIALS SCIENCE↗

Improved experimental and diagnostic techniques for dynamic tensile stress–strain measurement with a Kolsky tension bar

Kolsky tension bar experiments were improved for dynamic tensile stress–strain measurements with higher fidelity and minimal uncertainties. The difficulties associated with specimen gripping, relatively short gage section, and geometric discontinuity at the bar ends all compromise the accuracy of the traditional strain measurement method in a Kolsky tension bar experiment. Here in this study, an improved three-channel splitting-beam laser extensometer technique was developed to directly and independently track the displacement of the incident and transmission bar interfaces. By adopting a dual-channel configuration on the incident bar side, the resolution and measurement range of this laser extensometer were coordinated between the two channels to provide highly precise measurement at both small and large strains under high strain-rate loading condition. On the transmission bar side an amplified channel, similar to that used on the incident bar side, was adopted to measure the transmission bar displacement with high resolution. With this novel design, a maximum resolution of approximately 500 nm can be obtained for the bar displacement measurement, which corresponds to a strain of 0.0079% for a specimen with 6.35 mm gage length. To further improve the accuracy, a pair of lock nuts were used to tighten the tensile specimen to the bars in an effort not only to prevent the specimen from potential pre-torsional deformation and damage during installation, but also to provide better thread engagement between the specimen and the bar ends. As a demonstration of this technique, dynamic tensile stress–strain response of a 304L stainless steel was characterized with high resolution in both elastic and plastic deformations.

42 ENGINEERING↗

High-repetition rate, CEP-stable shortwave infrared source with two-cycle pulses for field-resolved spectroscopy

We report on a passively carrier-envelope phase (CEP)-stable optical parametric amplifier generating two-cycle pulses at 2060 nm with energies of up to 2.25 µJ operating at a repetition rate of 400 kHz, specifically designed for applications in field-resolved spectroscopy. The measured pulse duration is 13.6 fs, resulting in two cycles of the carrier wave. Due to the robust CEP-stable front-end design, we achieve an open-loop CEP stability of 250 mrad (rms) and the capability for fast CEP modulation.

47 OTHER INSTRUMENTATION↗

Hypersonic Boundary Layer Instability Over a Corner

A boundary-layer transition study over a compression corner was conducted under a hypersonic flow condition. Due to the discontinuities in boundary layer flow, the full Navier-Stokes equations were solved to simulate the development of disturbance in the boundary layer. A linear stability analysis and PSE method were used to get the initial disturbance for parallel and non-parallel flow respectively. A 2-D code was developed to solve the full Navier-stokes by using WENO(weighted essentially non-oscillating) scheme. The given numerical results show the evolution of the linear disturbance for the most amplified disturbance in supersonic and hypersonic flow over a compression ramp. The nonlinear computations also determined the minimal amplitudes necessary to cause transition at a designed location.

Balakumar, Ponnampalam↗

A Novel Reconfigurable GaN Based Fully Solid-State Microwave Power Module for Communications/Radar Applications

The paper presents the design, integration, and performance of a novel S-/X-band, GaN based, fully solid-state microwave power module (SSMPM). The SSMPM includes diplexers, pre-amplifiers, a multi-stage medium power amplifier, SPDT switches, and CW/Pulsed high-power amplifiers. These components are synergistically integrated such that a single SSMPM is capable of being dynamically reconfigured to function as a S-/X-band amplifier for TT&C/telecommunications for command/science date downlink and radar for remote sensing onboard a planetary exploration spacecraft. The SSMPM is capable of delivering Psat of 39.5 dBm (~10 W CW) at S-band, Psat of 46.7 dBm (~45 W CW) at X-band, and Psat of 51.2 dBm (~122 W Pulsed) at X-band.

Microwave Amplifier↗

Initial Results from NASA’s Low-Cost Optical Terminal (LCOT) at Goddard Space Flight Center

We present the initial results from testing of the Low-Cost Optical Terminal (LCOT) at NASA-Goddard Space Flight Center (GSFC). LCOT is designed to be a single modular design that can be quickly reconfigured to support different laser communication missions. LCOT is built around a 70 cm commercially available telescope designed with optical and quantum communications in mind. We have installed a state-of-the-art adaptive optics system, novel high-power laser amplifiers, and other innovative subsystems developed by our team to facilitate laser communications. We have conducted tests of our LCOT system against operational space terminals, demonstrating our ability to receive a downlink and transmit an uplink. We show the results of these tests and give analysis of the results.

Laser communications↗

Initial Results from NASA’s Low-Cost Optical Terminal (LCOT) at Goddard Space Flight Center

We present the initial results from testing of the Low-Cost Optical Terminal (LCOT) at NASA-Goddard Space Flight Center (GSFC). LCOT is designed to be a single modular design that can be quickly reconfigured to support different laser communication missions. LCOT is built around a 70 cm commercially available telescope designed with optical and quantum communications in mind. We have installed a state-of-the-art adaptive optics system, novel high-power laser amplifiers, and other innovative subsystems developed by our team to facilitate laser communications. We have conducted tests of our LCOT system against operational space terminals, demonstrating our ability to receive a downlink and transmit an uplink. We show the results of these tests and give an analysis of the results.

Ground terminals↗

New Beam Loss Monitor for 12 GeV Upgrade

This paper describes a new VME based machine protection Beam Loss Monitor (BLM) signal processing board designed at Jefferson Lab to replace the current CAMAC based BLM board. The new eight-channel BLM signal processor has linear, logarithmic, and integrating amplifiers that simultaneously provide the optimal signal processing for each application. Amplified signals are digitized and then further processed through a Field Programmable Gate Array (FPGA). Combining both the diagnostic and machine protection functions in each channel allows the operator to tune-up and monitor beam operations while the machine protection is integrating the same signal. Other features include extensive built-in-self-test, fast shutdown interface (FSD), and 16-Mbit buffers for beam loss transient play-back. The new VME BLM board features high sensitivity, high resolution, and low cost per channel.

43 PARTICLE ACCELERATORS↗

Nancy Grace Roman Space Telescope Observatory Implementation and Challenges

NASA’s Nancy Grace Roman Space Telescope (Roman) is a deep space infrared observatory with a Hubble-sized telescope and wide field of regard with a boresight view greater than 200 times that of the Hubble Wide Field Camera 3infrared field of view, that will conduct a suite of science surveys to characterize dark energy and expand the census of exoplanets in our galaxy. Roman will also demonstrate exoplanet coronagraphy with active wavefront control technology and provide general investigator opportunities for the science community. Roman is finishing the critical design phase and is planning for launch in 2026. It will operate at the second Sun-Earth-Moon Lagrange for a five-year primary mission life. The Observatory features a telescope with an existing, repurposed 2.4m primary mirror, a Wide Field Instrument with a near-infrared detector focal plane array and optical elements for imaging and spectroscopy, as well as a Coronagraph instrument technology demonstration for direct imaging and spectroscopy of exoplanets. The telescope and instruments are mounted to an Instrument Carrier for optical metering and isolation from Spacecraft-induced disturbances. The Spacecraft includes a Bus, Solar Array Sunshield, Deployable Aperture Cover, Outer Barrel Assembly, and Star Tracker/Inertial Reference Unit Bench. When fully integrated, Roman will be the largest Observatory assembled and tested at NASA’s Goddard Space Flight Center. The development of scientific satellites is challenging and pushes engineering boundaries to broaden scientific knowledge. The Roman mission implementation is a prime example and expected challenges have been amplified by the foundational decision to use existing, repurposed telescope components. Other unique aspects of the Roman mission, including its survey nature, large data volume, and Observatory packaging, create constrained design spaces that drive competing requirements across Observatory subsystems. Given these challenges, systems engineering has been a critical discipline in balancing implementation decisions and will continue to play a key role in the development of the Roman mission. This paper will discuss details of the Roman Observatory configuration, systems engineering challenges and the decision-making process used to mature the Roman Space Telescope from preliminary design to implementation.

Lisa M L Bartusek↗

Development and Utility of a Four-Channel Scanner for Wildland Fire Research and Applications

The Airborne Infrared Disaster Assessment System (AIRDAS) is a four-channel scanner designed and built at NASA-Ames for the specific task of supporting research and applications on fire impacts on terrestrial and atmospheric processes and also of serving as a vital instrument in the assessment of natural and man-induced disasters. The system has been flown on numerous airframes including the Navajo, King-Air, C0130, and Lear Jet 310 and a 206. The system includes a configuration composed of a 386 PC computer workstation, a non-linear detector amplifier, a sixteen-bit digitizer, dichroic filters, and Exabyte 8500 5Gb Tape output, VHS tape output, a Rockwell GPS and a 2-axis gyro. The AIRDAS system collects digital data in four wavelength regions, which can be filtered: band 1 (0.61-0.68 microns), band 2 (1.57-1.7 microns), band 3 (3.6-5.5 microns), and band 4 (5.5-13.0 microns), an FOV of 108 degrees, an IFOV of 2.62 mrads, and a digitized swath width of 720 pixels. The inclusion of the non-linear detector amplifier allows for the accurate measurement of emitted temperature from fires and hot spots. Lab testing of the scanner has indicated temperature assessments of 800 C without detector saturation. This has advantages over previous systems which were designed for thermal measurement of earth background temperatures, and were ill-equipped for accurate determination of high intensity conditions. The scanner has been flown successfully on data collection missions since 1992 in the western US as well as Brazil. These and other research and applications responses will be presented along with an assessment of future directions with the system.a

Ambrosia, Vincent G.↗

Bridging gaps in permafrost-shrub understanding

Permafrost, permanently frozen ground which underlies much of the Arctic and sub-Arctic, is influenced by deciduous shrubs, yet our understanding of permafrost-shrub interactions is limited. This is largely due to a lack of widespread, long-term, high-quality observations across Arctic and sub-Arctic systems, which are difficult to study due to their remote locations. Shrubs are rapidly expanding in many areas of Arctic tundra and can either amplify or inhibit permafrost thaw, making it crucial that we can understand and predict permafrost-shrub interactions. As we have limited time and resources to make observations, we must design our field campaigns to be as impactful as possible. Below we outline the current state of knowledge and give suggestions about how we can maximize our fieldwork’s impact. From field studies conducted around the Arctic, we know that shrubs generally have a cooling effect on permafrost in the summer, largely caused by the shrub canopy shading the soil. However, summertime cooling can be counteracted by a warming effect in winter, caused by the trapping of blowing snow by shrubs, which leads to increased snow depths. In addition to these commonly observed effects, both observations and models show that other local factors such as climate, soil, snow, and disturbances can interact to cause contrasting dominant effects on permafrost temperatures. For example, shrubs that protrude through the snowpack have been observed to cool permafrost in winter via thermal bridging between the air above the snow and the soil below. However, at other research sites, protruding shrubs lower the surface albedo and cause earlier snowmelt in spring, amplifying permafrost thaw by exposing the soil to thawing earlier. Protruding shrubs have also been observed to induce snow melt in autumn, creating ice layers at the snow surface that prevent further snow accumulation and eliminate the ability of shrubs to trap blowing snow, thereby reducing the winter warming effect. While we understand the physical processes that lead to these effects, we cannot explain why we observe different effects between sites.

54 ENVIRONMENTAL SCIENCES↗

Design, Fabrication, and Testing of a TiN Ti TiN Trilayer KID Array for 3mm CMB Observations

Kinetic inductance detectors (KIDs) are a promising technology for astronomical observations over a wide range of wavelengths in the mm and sub-mm regime. Simple fabrication, in as little as one lithographic layer, and passive frequency-domain multiplexing, with readout of up to 1000 pixels on a single line with a single cold amplifier, make KIDs an attractive solution for high-pixel-count detector arrays. We are developing an array that optimizes KIDs for optical frequencies near 100GHz to expand their usefulness in mm-wave applications, with a particular focus on CMBB-mode measurement efforts in association with the QUBIC telescope. We have designed, fabricated, and tested a 20-pixel prototype array using a simple quasi lumped microstrip design and pulsed DC reactive magnetron-sputtered TiNTiTiN trilayer resonators, optimized for detecting 100GHz (3mm) signals. Here we present a discussion of design considerations for the array, as well as preliminary detector characterization measurements and results from a study of TiN trilayer properties.

passive frequency-domain multiplexing↗

Implementation of a multichannel soft x-ray diagnostic for electron temperature measurements in TJ-II high-density plasmas

Based on the multi-foil technique, a multichannel soft x-ray diagnostic for electron temperature measurements has been recently implemented in the TJ-II stellarator. The diagnostic system is composed by four photodiodes arrays with beryllium filters of different thickness. An in-vacuum amplifier board is coupled to each array, aiming at preventing induced noise currents. The Thomson scattering and the vacuum ultraviolet survey diagnostics are used for assessing plasma profiles and composition, being the analysis carried out with the radiation code IONEQ. The electron temperature is determined through the different signal-pair ratios with temporal and spatial resolution. The design and preliminary results from the diagnostic are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗