Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AIRS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Energy and economic performance analysis of an open cycle solar desiccant dehumidification air-conditioning system for application in Hong Kong

In this article, a transient simulation model and the EnergyPlus were used to study the energy performance and economical feasibility for integrating a solar liquid desiccant dehumidification system with a conventional vapor compression air-conditioning system for the weather condition of Hong Kong. The vapor compression system capacity in the solar assisted air-conditioning system can be reduced to 19 kW from original 28 kW of a conventional air-conditioning system as a case study due to the solar desiccant cooling. The economical performance of the solar desiccant dehumidification system is compared with that of the conventional air-conditioning system. The results show that the energy saving potentials due to incorporation of the solar desiccant dehumidification system in a traditional air-conditioning system is significant for the hot wet weather in Hong Kong due to higher COP resulted from higher supply chilled water temperature from chiller plants. The annual operation energy savings for the hybrid system is 6760 kWh and the payback period of the hybrid system is around 7 years. The study shows that the solar assisted air-conditioning is a viable technology for utilizations in subtropical areas. (author)

14 SOLAR ENERGY↗

Air separation and N 2 purification with Ba 0.15 Sr 0.85 FeO 3-$δ$ via a two-step thermochemical process

Thermochemical air separation to produce high-purity N 2 was demonstrated in a vertical tube reactor via a two-step reduction–oxidation cycle with an A-site substituted perovskite Ba 0.15 Sr 0.85 FeO 3–δ (BSF1585). BSF1585 particles were synthesized and characterized in terms of their chemical, morphological, and thermophysical properties. A thermodynamic cycle model and sensitivity analysis using computational heat and mass transfer models of the reactor were used to select the system operating parameters for a concentrating solar thermal-driven process. Thermal reduction up to 800 °C in air and temperature-swing air separation from 800 °C to minimum temperatures between 400 and 600 °C were performed in the reactor containing a 35 g packed bed of BSF1585. The reactor was characterized for dispersion, and air separation was characterized via mass spectrometry. Gas measurements indicated that the reactor produced N 2 with O 2 impurity concentrations as low as 0.02 % for > 30 min of operation. Additionally, a parametric study of air flow rates suggested that differences in observed and thermodynamically predicted O 2 impurities were due to imperfect gas transport in the bed. Temperature swing reduction/oxidation cycling experiments between 800 and 400 °C in air were conducted with no statistically significant degradation in N 2 purity over 50 cycles.

14 SOLAR ENERGY↗

Aqueous Polysulfide–Air Battery with a Mediator-Ion Solid Electrolyte and a Copper Sulfide Catalyst for Polysulfide Redox

Aqueous sodium polysulfide–air batteries are a promising system for enabling low-cost, high energy density, environmentally benign batteries for grid-scale deployment. However, the sluggish redox kinetics of aqueous polysulfide requires the use of a catalyst. Cobalt sulfide is a traditional catalyst with good activity and stability, but it uses expensive and toxic cobalt. This study demonstrates for the first time the long-term cycling performance of a sodium polysulfide–air battery with a low-cost copper sulfide catalyst for polysulfide redox. Alkaline sodium polysulfide anolyte is paired with an acidic sodium phosphate buffered air catholyte by means of a Na+-ion solid-state electrolyte, which eliminates chemical crossover between the two electrodes while serving as a mediator-ion solid electrolyte. Long-term cycling is achieved by means of a decoupled charge and discharge air electrode. Furthermore, the effect of CuS redox activity in the polysulfide–air voltage window is tested by pre-discharging CuS in LiOH and in NaOH. It was found that the sodium polysulfide–air batteries with CuS catalyst exhibit good cycling performance, with the overpotential only showing a modest increase of 0.09 V after 100 cycles. Batteries assembled with CuS pre-discharged in LiOH exhibit a small boost in performance, while batteries assembled with CuS pre-discharged in NaOH show a small performance decline.

25 ENERGY STORAGE↗

The behavior of NaOH at the air-water interface, a computational study

Molecular dynamics simulations with a polarizable multi-state empirical valence bond model were carried out to investigate NaOH dissociation and pairing in water bulk and at the air-water interface. It was found that NaOH readily dissociates in the bulk, and the effect of the air-water interface on NaOH dissociation is fairly minor. Also, NaOH complexes were found to be strongly repelled from the air-water interface, which is consistent with surface tension measurements. At the same time, a very strong preference for the hydroxide anion to be oriented towards the air was found that persisted a few angstroms towards the liquid from the Gibbs dividing surface of the air-water interface. This was due to a preference for the hydroxide anion to have its hydrogen pointing towards the air, and the fact that the sodium ion was more likely to be found near the hydroxide oxygen than hydrogen. As a consequence, the simulation results show that surfaces of NaOH solutions should be negatively charged, in agreement with experimental observations, but also that the hydroxide has little surface affinity. This provides the possibility that the surface of water can be devoid of hydroxide anions, but still have a strong negative charge. This work was supported by the US Department of Energy Basic Energy Sciences' Chemical Sciences, Geosciences & Biosciences Division. Pacific Northwest National Laboratory is operated by Battelle for the US Department of Energy.

08 HYDROGEN↗

Optical breakdown threshold investigation of 1064 nm laser induced air plasmas

We present the theoretical and experimental measurements and analysis of the optical breakdown threshold for dry air by 1064 nm infrared laser radiation and the significance of the multiphoton and collisional cascade ionization process on the breakdown threshold measurements over pressures range from 10 to 2000 Torr. Theoretical estimates of the breakdown threshold laser intensities and electric fields are obtained using two distinct theories namely multiphoton and collisional cascade ionization theories. The theoretical estimates are validated by experimental measurements and analysis of laser induced breakdown processes in dry air at a wavelength of 1064 nm by focusing 450 mJ max, 6 ns, 75 MW max high-power 1064 nm IR laser radiation onto a 20 {mu}m radius spot size that produces laser intensities up to 3 - 6 TW/cm{sup 2}, sufficient for air ionization over the pressures of interest ranging from 10 to 2000 Torr. Analysis of the measured breakdown threshold laser intensities and electric fields are carried out in relation with classical and quantum theoretical ionization processes, operating pressures. Comparative analysis of the laser air breakdown results at 1064 nm with corresponding results of a shorter laser wavelength (193 nm) [M. Thiyagarajan and J. E. Scharer, IEEE Trans. Plasma Sci. 36, 2512 (2008)] and a longer microwave wavelength (10{sup 8} nm) [A. D. MacDonald, Microwave Breakdown in Gases (Wiley, New York, 1966)]. A universal scaling analysis of the breakdown threshold measurements provided a direct comparison of breakdown threshold values over a wide range of frequencies ranging from microwave to ultraviolet frequencies. Comparison of 1064 nm laser induced effective field intensities for air breakdown measurements with data calculated based on the collisional cascade and multiphoton breakdown theories is used successfully to determine the scaled collisional microwave portion. The measured breakdown threshold of 1064 nm laser intensities are then scaled to classical microwave breakdown theory after correcting for the multiphoton ionization process for different pressures and good agreement, regarding both pressure dependence and breakdown threshold electric fields, is obtained. The effect of the presence of submicron particles on the 1064 nm breakdown threshold was also investigated. The measurements show that higher breakdown field is required, especially at lower pressures, and in close agreement with classical microwave breakdown theory and measurements in air.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A handheld low temperature atmospheric pressure air plasma gun for nanomaterial synthesis in liquid phase

A handheld low temperature atmospheric pressure air plasma gun based on a dielectric barrier structure with hollow electrodes was proposed. The portable plasma gun with an embedded mini air pump was driven by a 12 V direct voltage battery. The air plasma jet generated from the gun could be touched without a common shock hazard. Besides working in air, the plasma gun can also work in water. The diagnostic result of optical emission spectroscopy showed the difference in reactive species of air plasma jet between in air and in water. The plasma gun was excited in 20 ml chloroauric acid aqueous solution with a concentration of 1.214 mM. A significant amount of gold nanoparticles were synthesized after 2 min continuous discharge. The plasma gun with these unique features is applicable in plasma medicine, etching, and s-nthesis of nanomaterials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of air exposure duration and a-Si capping layer thickness on the performance of p-BaSi{sub 2}/n-Si heterojunction solar cells

Fabrication of p-BaSi{sub 2}(20 nm)/n-Si heterojunction solar cells was performed with different a-Si capping layer thicknesses (d{sub a-Si}) and varying air exposure durations (t{sub air}) prior to the formation of a 70-nm-thick indium-tin-oxide electrode. The conversion efficiencies (η) reached approximately 4.7% regardless of t{sub air} (varying from 12–150 h) for solar cells with d{sub a-Si} = 5 nm. In contrast, η increased from 5.3 to 6.6% with increasing t{sub air} for those with d{sub a-Si} = 2 nm, in contrast to our prediction. For this sample, the reverse saturation current density (J{sub 0}) and diode ideality factor decreased with t{sub air}, resulting in the enhancement of η. The effects of the variation of d{sub a-Si} (0.7, 2, 3, and 5 nm) upon the solar cell performance were examined while keeping t{sub air} = 150 h. The η reached a maximum of 9.0% when d{sub a-Si} was 3 nm, wherein the open-circuit voltage and fill factor also reached a maximum. The series resistance, shunt resistance, and J{sub 0} exhibited a tendency to decrease as d{sub a-Si} increased. These results demonstrate that a moderate oxidation of BaSi{sub 2} is a very effective means to enhance the η of BaSi{sub 2} solar cells.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simulation of radiation energy release in air showers

A simulation study of the energy released by extensive air showers in the form of MHz radiation is performed using the CoREAS simulation code. We develop an efficient method to extract this radiation energy from air-shower simulations. We determine the longitudinal profile of the radiation energy release and compare it to the longitudinal profile of the energy deposit by the electromagnetic component of the air shower. We find that the radiation energy corrected for the geometric dependence of the geomagnetic emission scales quadratically with the energy in the electromagnetic component of the air shower with a second-order dependence on the atmospheric density at the position of the maximum shower development X {sub max}. In a measurement where X {sub max} is not accessible, this second order dependence can be approximated using the zenith angle of the incoming direction of the air shower with only a minor loss in accuracy. Our method results in an intrinsic uncertainty of 4% in the determination of the energy in the electromagnetic air-shower component, which is well below current experimental uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Air Sparging for Mixing Non-Newtonian Slurries

The mechanics of air sparger systems have been primarily investigated for aqueous-based Newtonian fluids. Tilton et al. (1982) [1] describes the fluid mechanics of air sparging systems in non-Newtonian fluids as having two primary flow regions. A center region surrounding the sparger, referred to as the region of bubbles (ROB), contains upward flow due to the buoyant driving force of the rising bubbles. In an annular region, outside the ROB, referred to as the zone of influence (ZOI), the fluid flow is reversed and is opposed to the direction of bubble rise. Outside the ZOI the fluid is unaffected by the air sparger system. The flow regime in the ROB is often turbulent, and the flow regime in the ZOI is laminar; the flow regime outside the ZOI is quiescent. Tests conducted with shear thinning non-Newtonian fluid in a 34-in. diameter tank showed that the ROB forms an approximately inverted cone that is the envelop of the bubble trajectories. The depth to which the air bubbles reach below the sparger nozzle is a linear function of the air-flow rate. The recirculation time through the ZOI was found to vary proportionally with the inverse square of the sparging air-flow rate. Visual observations of the ROB were made in both water and Carbopol®. The bubbles released from the sparge tube in Carbopol® were larger than those in water

air sparging↗

Hybrid Air-Electrode for Li/Air Batteries

A novel hybrid air-electrode is designed to improve the power density of Li/air batteries operating in an ambient environment. Three lithium insertion materials, MnO2, V2O5, and CFx (x = 1.0 to 1.15), are mixed with activated carbon to prepare different hybrid air-electrodes used in Li/air batteries. When compared with pure carbon-based Li/air batteries, the batteries using hybrid air-electrodes demonstrate significantly improved power capacities, especially for the CFx-based hybrid Li/air batteries. Because it is hydrophobic, CFx also facilitates the formation of air-flow channels in the carbon matrix, and alleviates air-electrode blocking problem during the discharge process. These hybrid air-electrodes provide a promising approach to improve the power density of Li/air batteries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Air quality and health impacts of the 2020 wildfires in California

Abstract Background Wildfires in 2020 ravaged California to set the annual record of area burned to date. Clusters of wildfires in Northern California surrounded the Bay Area covering the skies with smoke and raising the air pollutant concentrations to hazardous levels. This study uses the Fire Inventory from the National Center for Atmospheric Research database and the Community Multiscale Air Quality model to estimate the effects of wildfire emissions on air quality during the period from August 16 to October 28 of 2020. In addition, low-cost sensor data for fine particulate matter (PM 2.5 ) from the PurpleAir network is used to enhance modeled PM 2.5 concentrations. The resulting impacts on ozone and PM 2.5 are used to quantify the health impacts caused by wildfires using the Benefits Mapping and Analysis Program – Community Edition. Results Wildfire activity significantly increased direct PM 2.5 emissions and emissions of PM 2.5 and ozone precursors. Direct PM 2.5 emissions surged up to 38 times compared to an average day. Modeling results indicated that wildfires alone led to a rise in ozone daily maximum 8-h average by up to 10 ppb and exceeded PM 2.5 air quality standards in numerous locations by up to 10 times. While modeled PM 2.5 concentrations were lower than measurements, correcting these with PurpleAir data improved the accuracy. The correction using PurpleAir data increased estimates of wildfire-induced mortality due to PM 2.5 exposure by up to 16%. Conclusions The increased hospital admissions and premature mortality attributed to wildfires were found to be comparable to the health impacts avoided by strategies aimed at meeting ozone and PM2.5 air quality standards. This suggests that widespread wildfire emissions can negate years of efforts dedicated to controlling air pollution. The integration of low-cost sensor data proved invaluable in refining the estimates of health impacts from PM2.5 resulting from wildfires.

54 ENVIRONMENTAL SCIENCES↗

High Performance Cathodes for Li-Air Batteries

The overall objective of this project was to develop and fabricate a multifunctional cathode with high activities in acidic electrolytes for the oxygen reduction and evolution reactions for Li-air batteries. It should enable the development of Li-air batteries that operate on hybrid electrolytes, with acidic catholytes in particular. The use of hybrid electrolytes eliminates the problems of lithium reaction with water and of lithium oxide deposition in the cathode with sole organic electrolytes. The use of acid electrolytes can eliminate carbonate formation inside the cathode, making air breathing Li-air batteries viable. The tasks of the project were focused on developing hierarchical cathode structures and bifunctional catalysts. Development and testing of a prototype hybrid Li-air battery were also conducted. We succeeded in developing a hierarchical cathode structure and an effective bifunctional catalyst. We accomplished integrating the cathode with existing anode technologies and made a pouch prototype Li-air battery using sulfuric acid as catholyte. The battery cathodes contain a nanoscale multilayer structure made with carbon nanotubes and nanofibers. The structure was demonstrated to improve battery performance substantially. The bifunctional catalyst developed contains a conductive oxide support with ultra-low loading of platinum and iridium oxides. The work performed in this project has been documented in seven peer reviewed journal publications, five conference presentations, and filing of two U.S. patents. Technical details have been documented in the quarterly reports to DOE during the course of the project.

25 ENERGY STORAGE↗

Optimization of Ventilation Energy Demands and Indoor Air Quality in the ZEBRAlliance Homes

High-performance homes require that ventilation energy demands and indoor air quality (IAQ) be simultaneously optimized. Researchers have primarily addressed these two areas independently because of the assumption that their goals have to be mutually exclusive. This assumption is based on the fact that the typical mechanism to reduce the concentration of indoor air pollutants has been dilution through increased ventilation, which causes heating, ventilation and air conditioning (HVAC) units to consume more energy. High-performance homes aim to provide the essential energy end-uses (for example, water heating, refrigeration, space heating, and air conditioning) in an energy efficient manner. Given that IAQ is among these essential energy end-uses, we investigated means to optimize the concentration of indoor air pollutants and ventilation energy demands. To this end, we conducted tests in four houses located in Oak Ridge, TN, that were 11 to 20 months old, energy efficient (i.e., expected to consume 50% less energy than a house built per the 2006 International Residential Code), airtight (i.e., natural ventilation rate ~0.02 to 0.2 h -1 ), unoccupied, and unfurnished. Our evaluation consisted of identifying air pollutants of concern in these homes that could generally serve as indicators of IAQ, and conducting field experiments and computer simulations to determine the effectiveness and energy required by various techniques that lessened the concentration of these contaminants.

formaldehyde↗

An Innovative Reactor Technology to Improve Indoor Air Quality

As residential buildings achieve tighter envelopes in order to minimize energy used for space heating and cooling, accumulation of indoor air pollutants such as volatile organic compounds (VOCs), becomes a major concern causing poor air quality and increased health risks. Current VOC removal methods include sorbents, ultraviolet photocatalytic oxidation (UVPCO), and increased ventilation, but these methods do not capture or destroy all VOCs or are prohibitively expensive to implement. TIAX's objective in this program was to develop a new VOC removal technology for residential buildings. This novel air purification technology is based on an innovative reactor and light source design along with UVPCO properties of the chosen catalyst to purify indoor air and enhance indoor air quality (IAQ). During the program we designed, fabricated and tested a prototype air purifier to demonstrate its feasibility and effectiveness. We also measured kinetics of VOC destruction on photocatalysts, providing deep insight into reactor design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Air Barriers for Residential Buildings

In this project we aimed to increase the knowledgebase on air barriers for residential buildings. To this end, we evaluated nine air barrier assemblies following a modified version of the ASTM E2357 Standard Test Method from the American Society for Testing and Materials. The assemblies included the eight air barrier types that are readily available in the US, even if some of these are currently mostly used in commercial construction. This decision was made because technologies that are utilized in the commercial sector may be adopted by residential builders in the future. We also followed ASTM Standard E283 to estimate the air leakage rates through flow paths that are typically found in walls before and after these were sealed following typical techniques. Assessed leakage paths included wall to foundation joints, as well as penetrations through air barrier systems due to PVC pipes, steel ducts, electrical outlets and brick ties. In addition to the gathered measurements, this report also includes recommendations and considerations on each of the air barrier types. Findings from this research will contribute to the improvement of construction practices that will help meet airtightness requirements set by building codes and programs that seek to reduce energy consumption in homes.

Air Barrier↗

Quantitative Assessment of Detection Frequency for the INL Ambient Air Monitoring Network

A quantitative assessment of the Idaho National Laboratory (INL) air monitoring network was performed using frequency of detection as the performance metric. The INL air monitoring network consists of 37 low-volume air samplers in 31 different locations. Twenty of the samplers are located on INL (onsite) and 17 are located off INL (offsite). Detection frequencies were calculated using both BEA and ESER laboratory minimum detectable activity (MDA) levels. The CALPUFF Lagrangian puff dispersion model, coupled with 1 year of meteorological data, was used to calculate time-integrated concentrations at sampler locations for a 1-hour release of unit activity (1 Ci) for every hour of the year. The unit-activity time-integrated concentration (TICu) values were calculated at all samplers for releases from eight INL facilities. The TICu values were then scaled and integrated for a given release quantity and release duration. All facilities modeled a ground-level release emanating either from the center of the facility or at a point where significant emissions are possible. In addition to ground-level releases, three existing stacks at the Advanced Test Reactor Complex, Idaho Nuclear Technology and Engineering Center, and Material and Fuels Complex were also modeled. Meteorological data from the 35 stations comprising the INL Mesonet network, data from the Idaho Falls Regional airport, upper air data from the Boise airport, and three-dimensional gridded data from the weather research forecasting model were used for modeling. Three representative radionuclides identified as key radionuclides in INL’s annual National Emission Standards for Hazardous Air Pollutants evaluations were considered for the frequency of detection analysis: Cs-137 (beta-gamma emitter), Pu-239 (alpha emitter), and Sr-90 (beta emitter). Source-specific release quantities were calculated for each radionuclide, such that the maximum inhalation dose at any publicly accessible sampler or the National Emission Standards for Hazardous Air Pollutants maximum exposed individual location (i.e., Frenchman’s Cabin) was no more than 0.1 mrem yr–1 (i.e., 1% of the 10 mrem yr–1 standard). Detection frequencies were calculated separately for the onsite and offsite monitoring network. As expected, detection frequencies were generally less for the offsite sampling network compared to the onsite network. Overall, the monitoring network is very effective at detecting the potential releases of Cs-137 or Sr-90 from all sources/facilities using either the ESER or BEA MDAs. The network was less effective at detecting releases of Pu-239. Maximum detection frequencies for Pu-239 using ESER MDAs ranged from 27.4 to 100% for onsite samplers and 3 to 80% for offsite samplers. Using BEA MDAs, the maximum detection frequencies for Pu-239 ranged from 2.1 to 100% for onsite samplers and 0 to 5.9% for offsite samplers. The only release that was not detected by any of the samplers under any conditions was a release of Pu-239 from the Idaho Nuclear Technology and Engineering Center main stack (CPP-708). The methodology described in this report could be used to improve sampler placement and detection frequency, provided clear performance objectives are defined.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal-Hydraulic Analysis of an Experimental Reactor Cavity Cooling System with Air. Part I: Experiments; Part II: Separate Effects Tests and Modeling

This experimental study investigates the thermal hydraulic behavior and the heat removal performance for a scaled Reactor Cavity Cooling System (RCCS) with air. A quarter-scale RCCS facility was designed and built based on a full-scale General Atomics (GA) RCCS design concept for the Modular High Temperature Gas Reactor (MHTGR). The GA RCCS is a passive cooling system that draws in air to use as the cooling fluid to remove heat radiated from the reactor pressure vessel to the air-cooled riser tubes and discharged the heated air into the atmosphere. Scaling laws were used to preserve key aspects and to maintain similarity. The scaled air RCCS facility at UW-Madison is a quarter-scale reduced length experiment housing six riser ducts that represent a 9.5° sector slice of the full-scale GA air RCCS concept. Radiant heaters were used to simulate the heat radiation from the reactor pressure vessel. The maximum power that can be achieved with the radiant heaters is 40 kW with a peak heat flux of 25 kW per meter squared. The quarter-scale RCCS was run under different heat loading cases and operated successfully. Instabilities were observed in some experiments in which one of the two exhaust ducts experienced a flow reversal for a period of time. The data and analysis presented show that the RCCS has promising potential to be a decay heat removal system during an accident scenario.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Miniaturized Air-to-Refrigerant Heat Exchangers

Air-to-refrigerant Heat eXchangers (HX) are an essential component of Heating, Ventilation, Air-Conditioning, and Refrigeration (HVAC&R) systems, serving as the main heat transfer component. The major limiting factor to HX performance is the large airside thermal resistance. Recent literature aims at improving heat transfer performance by utilizing enhancement methods such as fins and small tube diameters; this has lead to almost exhaustive research on the microchannel HX (MCHX). The objective of this project is to develop a miniaturized air-to-refrigerant HX with at least 20% reduction in volume, material volume, and approach temperature compared to current state-of-the-art multiport flat tube designs and also be capable of production within five years. Moreover, the proposed HX’s are expected to have good water drainage and should succeed in both evaporator and condenser applications. The project leveraged Parallel-Parametrized Computational Fluid Dynamics (PPCFD) and Approximation-Assisted Optimization (AAO) techniques to perform multi-scale analysis and shape optimization with the intent of developing novel HX designs whose thermal-hydraulic performance exceeds that of state-of-the-art MCHX. Nine heat exchanger geometries were initially chosen for detailed analysis, selected from 35+ geometries which were identified in previous work at the University of Maryland, College Park. The newly developed optimization framework was exercised for three design optimization problems: (DP I) 1.0kW radiator, (DP II) 10kW radiator and (DP III) 10kW two-phase HX. DP I consisted of the design and optimization of 1.0kW air-to-water HX’s which exceeded the project requirements of 20% volume/material reduction and 20% better performance. Two prototypes for the 1.0kW HX were prototyped, tested and validated using newly-designed airside and refrigerant side test facilities. DP II, a scaled version DP I for 10kW air-to-water HX applications, also yielded optimized HX designs which met project requirements. Attempts to prototype a 10kW have presented unique manufacturing challenges, especially regarding tube blockages and structural stability. DP III comprised optimizing two-phase HX’s for a 3.0Ton capacity in a heat pump / air-conditioning unit for cooling mode application using R410A as the working fluid. The HX’s theoretically address the project requirements. System-level analysis showed the HX’s achieved up to 15% improvement in COP while also reducing overall unit charge by 30-40%. The project methodology was capable of developing HX’s which can outperform current state-of-the-art MCHX by at least 20% reduction in volume, material volume, and approach temperature. Additionally, the capability for optimization using refrigerant charge as an objective function was developed. The five-year manufacturing feasibility of the proposed HX’s was shown to have a good outlook. Successful prototyping through both conventional manufacturing methods and next generation methods such as additive manufacturing was achieved.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗