Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “wind based electricity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Roadmap to Advance Heliostat Technologies for Concentrating Solar-Thermal Power

Heliostat-based concentrating solar-thermal power (CSP) systems can offer immense potential to provide low-cost, dispatchable renewable thermal and electrical energy to help achieve 100% decarbonized energy infrastructure in the United States. Heliostats are a major capital cost technology and a performance-dominating component of state-of-the-art commercial molten salt towers and Generation 3 CSP systems. In 2021, the U.S. Department of Energy (DOE) Solar Energy Technologies Office (SETO) launched the Heliostat Consortium (HelioCon), a five-year initiative to advance heliostat technologies. The HelioCon mission is threefold: (1) establish strategic core testing and modeling capabilities and infrastructure at national labs; (2) support heliostat technology development in relevant industries; and (3) serve as a central repository to integrate industry, academia, and other stakeholders for heliostat technology research, development, validation, and deployment. In this report, HelioCon presents a roadmapping study on advancing heliostat technologies, intended as a central reference for the whole CSP community.

14 SOLAR ENERGY↗

Wind Loading on Parabolic Trough Collectors: Wind and Structural Loads Measurements at an Operational Powerplant

Concentrated Solar Power (CSP) is a promising method for using solar power for electricity generation with thermal energy storage for industrial applications. Solar collectors constitute almost 1/3 of the total cost of the power plant. One of the primary drivers of unrealiability of these collectors is wind-driven loading of mirrors, support structures, and drives. To date, the design of the solar collector structures has relied on data from wind tunnels that do not adequately capture the dynamic effects observed at scale. NREL initiated a field measurement campaign at the operational Nevada Solar One (NSO) parabolic trough powerplant. At this plant, parabolic trough solar collectors track the sun from east to west in the course of a day and face varying wind loads depending on the wind properties and the angle of the troughs. The aim of the project is a detailed characterization of prevailing wind and turbulence conditions and resulting operational loads on parabolic troughs, providing insights into structural dynamic response, and generating a comprehensive wind-loading dataset for validating simulations of wind loading on collector structures. The measurements at NSO consist of sonic anemometers on masts at different heights to characterize the incoming flow and conditions at four trough rows at the edge of the trough field. In addition, a Doppler Lidar scans the horizontal plane above the troughs. The wind measurements at NSO have been continuously collecting data since October 2021 and are combined with structural load measurements that started in November 2022. The load measurements were installed on the same four outermost trough rows and include support structure bending moments, drive torque moments, dynamic accelerations of the spaceframe, mirror displacement, and tilt angles. Measurements are planned to continue until May 2023, providing a first-of-a-kind, high-resolution multi-month dataset of combined wind and load measurements. In this presentation, we show first results of the measurement campaign. Based on the measurements, we identified three main factors altering the flow over the parabolic troughs: Wind speed, wind direction, and the angle of the parabolic troughs. Most interactions between incoming wind and the trough field are observed when the wind blows perpendicular to the trough rows. In this case, the first rows experience the highest wind speed and block the downwind rows, creating conditions with decreased wind speed and enhanced turbulence within the trough field. Also, turbulent length scales are smaller after the first row. This leads to the highest static loads (bending and torque moments) at the first row but potentially increased dynamic loads within the field. We illustrate our findings with case studies focused on different wind conditions and will present fatigue analysis to highlight the impact of wind-driven loads on collector structures.

CSP collectors↗

FEED Study of Carbon Capture Inc. DAC and CarbonCure Utilization Using United States Steel's Gary Works Waste Plant

Direct Air Capture (DAC) has been proposed as a means of reducing atmospheric concentrations of CO2. While DAC has been evaluated through lab-scale, bench-scale, and small-scale pilot units, large-scale deployment has not been achieved. Feasibility studies are one tool to understand the potential design, operation, performance, and impact of commercial-scale DAC. This paper presents the results of a feasibility study for a passive DAC system deployed at >100,000 tpy scale in three different regions across the U.S. and awarded to Carbon Collect by the U.S. Department of Energy National Energy Technology Laboratory (DOE NETL). The MechanicalTree™technology has been designed and engineered by Carbon Collect based on the concept initially developed at Arizona State University Center for Negative Carbon Emissions. It uses a tower of stacked, sorbentcontaining disks supported by a lifting mechanism, exposed to the air to capture CO2 during the adsorption phase. The disks are then lowered into a regeneration chamber for vacuum and steam regeneration to produce CO2 product during the desorption step. The modular tree design allows large installations with repeatable, mass-manufactured units connected to common utilities such as steam supply, vacuum, and CO2 processing for compression and geologic storage. The passive DAC system eliminates the equipment and energy of forced air fans by using natural air circulation to contact the sorbent with the CO2 in the air. Because of this, the performance is dependent on the wind speed in addition to the temperature and relative humidity. Performance and flow rate fluctuations were incorporated into equipment and facility design with considerations for turndown to 10% of maximum rated flow to allow operation in all seasons. The feasibility study was undertaken to evaluate the technology in different regions and climates. Three locations were selected for this study representing different climates: Alabama (hot and humid), California (hot and arid), and Wyoming (continental). For each region, the adsorption/desorption cycle was optimized including tuning the heat integration and cycle timings. The performance of individual trees was then scaled to the full facility with the same design of more than 20,000 trees common between all regions. The installations had expected average CO2 capture rates of between 330,000 and 485,000 tonnes of CO2 per year depending on the climate. The initial engineering design for the facility at each location was performed with cost and performance estimates for the trees, carbon purification and compression, and the balance of plant. To supply thermal and electrical energy for the facility, carbon-free or low-carbon power must be considered. Options for low-carbon, continuous thermal and electrical energy were considered. The best-performing option from those considered was identified to be an electrically-heated molten salt energy storage system, powered by an on-site photovoltaic field. During molten salt thermal discharge, steam is produced from heat exchange with the molten salt and used to generate power in a steam turbine as well as steam for regenerating the DAC carbon trees. The thermal and electrical supply and analysis is presented in the context of low-carbon power for carbon removal. Modelling and economics of transportation and geologic storage of the CO2 is considered and presented for each location. The results of the feasibility study are incorporated into the presented techno-economic and life-cycle assessments. This work is intended to provide an understanding of the performance, cost, and impact of capturing CO2 at the commercial scale and the impact of climate and regional siting on the considered passive DAC system.

42 ENGINEERING↗

Optimal Electrification Using Renewable Energies: Microgrid Installation Model with Combined Mixture k-Means Clustering Algorithm, Mixed Integer Linear Programming, and Onsset Method

Optimal planning and design of microgrids are priorities in the electrification of off-grid areas. Indeed, in one of the Sustainable Development Goals (SDG 7), the UN recommends universal access to electricity for all at the lowest cost. Several optimization methods with different strategies have been proposed in the literature as ways to achieve this goal. This paper proposes a microgrid installation and planning model based on a combination of several techniques. The programming language Python 3.10 was used in conjunction with machine learning techniques such as unsupervised learning based on K-means clustering and deterministic optimization methods based on mixed linear programming. These methods were complemented by the open-source spatial method for optimal electrification planning: onsset. Four levels of study were carried out. The first level consisted of simulating the model obtained with a cluster, which is considered based on the elbow and k-means clustering method as a case study. The second level involved sizing the microgrid with a capacity of 40 kW and optimizing all the resources available on site. The example of the different resources in the Togo case was considered. At the third level, the work consisted of proposing an optimal connection model for the microgrid based on voltage stability constraints and considering, above all, the capacity limit of the source substation. Finally, the fourth level involved a planning study of electrification strategies based mainly on microgrids according to the study scenario. The results of the first level of study enabled us to obtain an optimal location for the centroid of the cluster under consideration, according to the different load positions of this cluster. Then, the results of the second level of study were used to highlight the optimal resources obtained and proposed by the optimization model formulated based on the various technology costs, such as investment, maintenance, and operating costs, which were based on the technical limits of the various technologies. In these results, solar systems account for 80% of the maximum load considered, compared to 7.5% for wind systems and 12.5% for battery systems. Next, an optimal microgrid connection model was proposed based on the constraints of a voltage stability limit estimated to be 10% of the maximum voltage drop. The results obtained for the third level of study enabled us to present selective results for load nodes in relation to the source station node. Finally, the last results made it possible to plan electrification using different network technologies and systems in the short and long term. The case study of Togo was taken into account. The various results obtained from the different techniques provide the necessary leads for a feasibility study for optimal electrification of off-grid areas using microgrid systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Lower Snake River Dams Contribution to Grid Services

Hydroelectric generation and water storage have long been components of the clean energy mix, providing both reliable steady output and operational flexibility. As variable renewable energy sources such as wind and solar increasingly replace traditional generation, the role of all flexible resources—including hydropower—in balancing supply and demand continues to evolve. This study examined the contribution of the Lower Snake River (LSR) Dam plants to Bonneville Power Administration grid services in maintaining power system reliability within the Western Interconnection. By analyzing publicly available data, the study evaluated various reliability services through performance metrics including energy capacity, balancing and ramping, voltage and reactive power support, frequency response, and transmission impact. Results indicated that the LSR plants deliver services as expected based on their size, contributing to the balancing process, ramping capabilities, and operational reserves, particularly during peak load conditions and weather events, while also providing measurable frequency and voltage support to the grid.

13 HYDRO ENERGY↗

Intense Equatorial Electrojet and Counter Electrojet caused by the 15 January 2022 Tonga Volcanic Eruption: Space and Ground-based Observations

Abstract Text: We present space and ground-based multi-instrument observations demonstrating the impact of the 2022 Tonga volcanic eruption on dayside equatorial electrodynamics. A strong counter electrojet (CEJ) was observed by Swarm and ground-based magnetometers on 15 January after the Tonga eruption and during the recovery phase of a moderate geomagnetic storm. Swarm also observed an enhanced equatorial electrojet (EEJ) preceding the CEJ in the previous orbit. The observed EEJ and CEJ exhibited complex spatiotemporal variations. We combine them with the Ionospheric Connection Explorer (ICON) neutral wind measurements to disentangle the potential mechanisms. Our analysis indicates that the geomagnetic storm had minimal impact; instead, a large-scale atmospheric disturbance propagating eastward from the Tonga eruption site was the most likely driver for the observed intensification and directional reversal of the equatorial electrojet. The CEJ was associated with strong eastward zonal winds in the E-region ionosphere, as a direct response to the lower atmosphere forcing. Plain-Language Summary: The Earth's E-region ionosphere (~100-150 km altitude) consists of both ionized and neutral gasses, and the two components are coupled through ion-neutral collisions. The state of this region is closely influenced by neutral atmospheric activities from the lower atmosphere and the variability of the solar drivers. On 15 January 2022, the Tonga volcano had a massive eruption and injected an enormous amount of mass and energy into the atmosphere causing disturbances in the E-region ionosphere or even higher. There was also a moderate geomagnetic storm that started one day before the eruption and ended days after. These conditions offer a unique opportunity to understand the different roles they play in controlling the ionosphere. Coordinated observations including the atmosphere, ionosphere and magnetosphere were made from both space and on the ground during this event. We analyzed the magnetic field and neutral wind data and found that a large-scale atmospheric disturbance generated by the volcano eruption was responsible for the observed directional reversal of the dayside equatorial electric field and electric current.

Guan Le↗

Investigating Short Circuit Models for Wind Turbine Generators

Short circuit study needs to be performed at the planning stage before connecting large gen erators with the electric grid. This study will reveal the impact of new generation on the fault levels of the grid. The fault levels will determine the rating of nearby equipment and setting of relays. However, a short circuit model of the new generation is required for this study. This report investigates and quantifies the short circuit models of different wind turbine generators (WTGs) and of wind farms, and using these models, explores the effects of the wind farms on the nearby switchgear. WTGs, commonly classified as Type 1, Type 2, Type 3, and Type 4, exhibit different short circuit behavior depending upon their architecture and controls. The short circuit model (synonymous to Thevenin model) of Type 1 WTG is well known; it comprises of a voltage source behind a transient reactance, X'. The transient reactance X' is derived using the reactance of stator, rotor and the magnetizing reactance. In case of Type 2 WTG, an external rotor resistance is used to increase the range of operating slips. The value of the external rotor resistance increases at higher operating slips. The effect of the external rotor resistance on the fault current response is analyzed by simulating a validated model of Type 2 WTG. The validation is performed using the field data from an actual 67-machine Type 2 wind farm located in Wyoming, USA. The results shows that the external rotor resistance should be considered in its Thevenin impedance for better accuracy. A wind farm contains a large number of WTGs, pad mounted transformers, and cables typically connected in a ‘daisy chain” configuration. The effect of these cable impedances on the short circuit model of Type 2 wind farm is examined using the validated models. It is found that the collector circuit cables inside the farm do not have a significant effect on the short circuit model of the farm. Based on this finding, a simple equivalencing procedure for the wind farm is proposed and validated. Faults inside and outside the wind farm are analyzed and recommendations to select main circuit breakers and generator circuit breakers are made. Type 3 WTG, also known as Doubly Fed Asynchronous Generator (DFAG), uses back to back converters in the rotor circuit to inject slip frequency voltage into the rotor circuit. Until recently, these machines used crowbar to short the rotor circuit during faults to protect the converter com ponents form high rotor currents resulting from faults. This type of WTG is simulated and the model is validated using field data from a 66-machine Type 3 wind farm in Wyoming, USA. The simulation study reveals that the crowbar feature is activated almost immediately after the fault takes place, and remains activated throughout the fault-period. This confirms that the short circuit model for Type 3 WTG with crowbar is similar to the model for Type 2 WTG. In the past, wind farms were allowed to disconnect during faults. However, recent grid codes around the world and in the United States demand that the wind farms be kept connected to the grid during faults, and provide certain reactive power quantified based on the voltage dip at the point of interconnection. This requirement, also called low voltage ride through (LVRT), can be accomplished by using Type 4 WTGs that employ full back to back converter interface between generators (permanent magnet synchronous generators are typically used) and the grid. However, the controls are proprietary, and hence the short circuit models are not well defined. This report proposes controls that enable the WTG to comply with the strictest grid codes, and based on this model, proposes a short circuit model of the Type 4 WTG. This model is not validated due to lack of validation data, but the use of grid code requirements as control objectives lends good credibility to the model. PSCAD/EMTDC ® , a powerful and time-tested time-domain simulation software is used to implement all models. This software is capable of modeling in detail all components of wind farms, and all components and controls of converters in time domain.

17 WIND ENERGY↗

Integration of Pumped Heat Energy Storage with Fossil-Fired Power Plant (Final Report)

The project team of Southwest Research Institute ® (SwRI ® ), Malta Inc. (Malta), and Luminant Generation Company LLC (Luminant) completed a feasibility study for the integration of a 100-MW, 10-hour (1000-MWh) Malta Pumped Heat Energy Storage (MPHES) system with multiple full-sized fossil-fired electricity generation units (EGU) in Luminant portfolio. MPHES is a long-duration, molten-salt-energy storage technology that uses turbomachinery and heat exchangers to transfer energy to a thermal storage media when charging, and removes the heat in a similar fashion when discharging. With high round trip efficiency (60-65%) and long lifespan (30+ years), MPHES provides economic benefits to the fossil-asset owners that can be scaled to integrate with assets across their portfolio. This technology uses hardware components, workforce personnel, and skillsets similar to those used by fossil EGUs, allowing for synergy when co-locating the two technologies. Luminant has approximately 39,000 megawatts of generation across 12 states, operating in six of the seven competitive markets in the U.S. and powered by a diverse portfolio of natural gas, nuclear, coal, and solar facilities. The DeCordova plant in Granbury, Texas, a simple cycle natural gas peaker power plant, was used as the fossil-fired asset in this project. The local market in Granbury, Texas has many influences, including several nearby power plants, a Luminant-owned nuclear plant (Comanche Peak), and substantial wind energy, which causes both negative pricing at night and high market volatility. Reducing false starts of the DeCordova plant and better responding to market volatility would be an economic advantage. Luminant is currently integrating battery storage plant on site to begin addressing these challenges. Integrating long-duration storage, like MPHES, would expand this capability beyond one hour of storage and have the potential to greatly reduce the total number of gas turbine starts. The MPHES charging requirement could help offset the overnight operating costs of Comanche Peak, which cannot load follow, and the nearby Luminant-owned Wise County combined cycle plant that cycles too often. Following the assessment of Luminant’s ERCOT-based portfolio for integration compatibility with Malta’s PHES system and the project tasks of conceptual study, technoeconomic analysis, technology gap assessment, and commercialization plan, the project team effort has resulted in several key outcomes: (1) Identification of market trends in a high-wind penetration market outside a major metropolitan area; (2) Creation of a dispatching model for the MPHES system and the pairing of Li-ion battery with a gas turbine in a real time market; (3) Revenue and cost estimations for operating MPHES alongside a gas peaker plant with real dispatching considerations and comparison with variations in the Malta implementation, including doubling the storage capacity and using two discharge drivetrains; (4) Potential carbon emission reductions possible by replacing gas turbine operation with Malta PHES operation; and (5) Summary of literature-based future market predictions for Texas.

20 FOSSIL-FUELED POWER PLANTS↗

Hydrogen Production System Scaling Using a High-Fidelity Simulation-Optimization Framework

Proton exchange membrane (PEM) electrolyzers are widely used for hydrogen production, yet few validated, high-fidelity tools can reliably guide scale-up. Using measured performance from a 50-hour hardware-in-the-loop pilot test, a physics-based, plant-level model of a 1.25 MW PEM electrolyzer and its balance-of-plant (BoP) subsystems is developed and validated. The model couples electrochemistry and thermal/flow submodels and is calibrated against pilot test data via a genetic algorithm (GA) workflow. Validation yields a mean absolute percentage error (APE) of 0.43% for cell voltage and stack power. Two scale-out strategies are then benchmarked under a common 7-day wind-and-photovoltaic (PV) profile: (i) linear duplication of 1.25 MW blocks and (ii) shared-BoP architectures. Sharing BoP between stacks reduces BoP energy by 27% at 10 MW and 34% at 100 MW (vs. linear duplication) and improves system specific energy consumption (SEC) to 52.9 and 52.6 kWh/kg, respectively (from 54.0 kWh/kg with linear duplication). Partial-load studies (25-100% set-point) show that cumulative hydrogen production remains nearly constant down to 50% load because all cases use the same weekly renewable-energy input. Below 50%, the power cap limits how much energy can be used within 168 h, which reduces hydrogen output. The model further indicates that the practical operating optimum lies between 50% and 85% load, where efficiency gains begin to appear without significant loss in hydrogen output. Moreover, the efficiency gains at lower loads are offset by reduced production. The validated framework supports scenario-based engineering trade-off studies for large configurations (10-100 MW) and for operating policies under variable renewables.

08 HYDROGEN↗

A Hybrid Energy System Workflow for Energy Portfolio Optimization

This manuscript develops a workflow, driven by data analytics algorithms, to support the optimization of the economic performance of an Integrated Energy System. The goal is to determine the optimum mix of capacities from a set of different energy producers (e.g., nuclear, gas, wind and solar). A stochastic-based optimizer is employed, based on Gaussian Process Modeling, which requires numerous samples for its training. Each sample represents a time series describing the demand, load, or other operational and economic profiles for various types of energy producers. These samples are synthetically generated using a reduced order modeling algorithm that reads a limited set of historical data, such as demand and load data from past years. Numerous data analysis methods are employed to construct the reduced order models, including, for example, the Auto Regressive Moving Average, Fourier series decomposition, and the peak detection algorithm. All these algorithms are designed to detrend the data and extract features that can be employed to generate synthetic time histories that preserve the statistical properties of the original limited historical data. The optimization cost function is based on an economic model that assesses the effective cost of energy based on two figures of merit: the specific cash flow stream for each energy producer and the total Net Present Value. An initial guess for the optimal capacities is obtained using the screening curve method. The results of the Gaussian Process model-based optimization are assessed using an exhaustive Monte Carlo search, with the results indicating reasonable optimization results. The workflow has been implemented inside the Idaho National Laboratory’s Risk Analysis and Virtual Environment (RAVEN) framework. The main contribution of this study addresses several challenges in the current optimization methods of the energy portfolios in IES: First, the feasibility of generating the synthetic time series of the periodic peak data; Second, the computational burden of the conventional stochastic optimization of the energy portfolio, associated with the need for repeated executions of system models; Third, the inadequacies of previous studies in terms of the comparisons of the impact of the economic parameters. The proposed workflow can provide a scientifically defendable strategy to support decision-making in the electricity market and to help energy distributors develop a better understanding of the performance of integrated energy systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Design, Modeling, and Testing of a Novel Inductor for Electric Vehicles: Iron Nitride Soft Magnetic Composites

New technology for electric vehicles (EVs) must meet the requirements of higher energy usage, lower costs, and more sustainable source materials. One promising material for EV power system components is iron nitride (IN) soft magnetic composites (SMCs) because of their competitive magnetic properties and high abundance of the source materials. As part of an ongoing program at Sandia National Laboratories, this project focused on using computer modeling to optimize the prototyping process for an iron nitride SMC toroidal inductor to reach a target inductance of 600 μH. Four inductors with different combinations of wiring (26 AWG and 20 AWG) and vol% loading of iron nitride (65 vol% and 50 vol%) were fabricated at Cal Poly and characterized using an LCR meter. These inductors were also modeled using COMSOL Multiphysics™ with the Magnetic Fields module. The inductance data from the experiment and the model show that the 65 vol% IN prototypes and models agree with about 8% difference, while the 50 vol% IN samples show about a 9% difference between the prototype and the model. These results suggest that the model can predict inductance with both accuracy and precision with low confidence for the given sample size of four. An additional parameter of AC resistance is studied but the AC resistance results from the inductors and from the model generally do not agree closely, suggesting that the current model used in the project does not fully capture the mechanisms behind AC resistance of the inductor. With the focus of the project on inductance, the percent difference results of less than 9% across the four inductors that were tested increases confidence in the model’s predictive capabilities for inductance only. Using the inductance results from both the model and experiment, the final suggested inductor design is a 65 vol% core with 150 windings of 20 AWG wire that is 8 cm across and 1.5 cm tall to reach the inductance goal of 600 μH based on analysis using the optimized COMSOLTM model.

33 ADVANCED PROPULSION SYSTEMS↗

Concerning the Charging of an Exploration Craft on and near a Small Asteroid

Introduction: An object immersed in an airless plasma environment will experience a natural process of surface charging in order to acheieve current balance, or zero net electric current to the object. It has been shown in recent computer simulations that the small-body plasma environment is very complex [1], considering effects of photoemission, topography, and formation of a plasma wake. For this work we consider an exploration craft (or astronaut) immersed within a plasma environment near an asteroid, which exhibits widely varying solar wind and photoelectric particle fluxes and continuously evolving illumination conditions. Objective: We aim to determine how an explo-ration craft or astronaut suit accumulates charge while located in the "nightside" asteroid wake where the particle fluxes are reduced, and in the dayside near-surface photoelectron sheath, by combining an object charging model [2] with kinetic simulations of a near-asteroid plasma environment [1]. We consider an astronaut floating near the asteroid while not in contact with the surface, as well as an astronaut moving along the surface using their hands/gloves to crawl along. Results: The modeling results suggest that remediation of triboelectric charge via accumulation of plasma currents is an important factor to consider when designing future NEA mission infrastructure, especially if repeated and frequent contact with the surface is planned. In shadowed regions such as the location shown in Fig. 1a, the plasma currents are so low (and the effective charge-remediation timescale so long, e.g. minutes to hours) that repeated contact with the surface tribocharges the glove in an uncontrollable fashion, as shown for two representative electron temperatures in Fig. 2a. The resulting buildup of significant negative charge would eventually initiate some other "current of last resort" [4] such as transport of positively-charged dust, field-emission from the glove, or significant alteration of environmental ion currents within the wake. In contrast, the few-meters-thick dayside photoelectron sheath in which the astronaut of Fig. 1b is immersed in is so rich in electrons (and hence so electrically conductive) that accumulated tribocharge dissipates almost instantaneously (e.g. in less than a ms) as shown in Fig. 2b. As our model astronaut orbits the NEA they would experience plasma currents and associated charge re-mediation times spanning many orders of magnitude, and the fusion between our numerical models provides a detailed understanding of the charging hazards possibly associated with contact-based NEA exploration.

Asteroid↗

Renewable Source Controls for Grid Stability

The goal of this study was to evaluate the small signal and transient stability of the Western Electricity Coordinating Council (WECC) under high penetrations of renewable energy, and to identify control technologies that would improve the system performance. The WECC is the regional entity responsible for coordinating and promoting bulk electric system reliability in the Western Interconnection. Transient stability is the ability of the power system to maintain synchronism after a large disturbance while small signal stability is the ability of the power system to maintain synchronism after a small disturbance. Transient stability analysis usually focuses on the relative rotor angle between synchronous machines compared to some stability margin. For this study we employed generator speed relative to system speed as a metric for assessing transient stability. In addition, we evaluated the system transient response using the system frequency nadir, which provides an assessment of the adequacy of the primary frequency control reserves. Small signal stability analysis typically identifies the eigenvalues or modes of the system in response to a disturbance. For this study we developed mode shape maps for the different scenarios. Prony analysis was applied to generator speed after a 1.4 GW, 0.5 second, brake insertion at various locations. Six different WECC base cases were analyzed, including the 2022 light spring case which meets the renewable portfolio standards. Because of the difficulty in identifying the cause and effect relationship in large power system models with different scenarios, several simulations were run on a 7-bus, 5-generator system to isolate the effects of different configurations. Based on the results of the study, for a large power system like the WECC, incorporating frequency droop into wind/solar systems provides a larger benefit to system transient response than replacing the lost inertia with synthetic inertia. From a small signal stability perspective, the increase in renewable penetration results in subtle changes to the system modes. In general, mode frequencies increase slightly, and mode shapes remain similar. The system frequency nadir for the 2022 light spring case was slightly lower than the other cases, largely because of the reduced system inertia. However, the nadir is still well above the minimum load shedding frequency of 59.5 Hz. Finally, several discrepancies were identified between actual and reported wind penetration, and additional work on wind/solar modeling is required to increase the fidelity of the WECC models.

power system stability↗

Economic Development Impacts of Community Wind Projects: A Review and Empirical Evaluation

Community wind projects have long been touted (both anecdotally and in the literature) to increase the economic development impacts of wind projects, but most analyses of community wind have been based on expected results from hypothetical projects. This report provides a review of previous economic development analyses of community wind projects and compares these projected results with empirical impacts from projects currently in operation. A review of existing literature reveals two primary conclusions. First, construction-period impacts are often thought to be comparable for both community-and absentee-owned facilities. Second, operations-period economic impacts are observed to be greater for community-owned projects. The majority of studies indicate that the range of increased operations-period impact is on the order of 1.5 to 3.4 times. New retrospective analysis of operating community wind projects finds that total employment impacts from completed community wind projects are estimated to be on the order of four to six 1-year jobs per-MW during construction and 0.3 to 0.6 long-term jobs per-MW during operations. In addition, when comparing retrospective results of community wind to hypothetical average absentee projects, construction-period employment impacts are 1.1 to 1.3 times higher and operations-period impacts are 1.1 to 2.8 times higher for community wind. Comparing the average of the completed community wind projects studied here with retrospective analysis of the first 1,000 MW of wind in Colorado and Iowa indicates that construction-period impacts are as much as 3.1 times higher for community wind, and operations-period impacts are as much as 1.8 times higher. Ultimately, wind projects are a source of jobs and economic development, and community wind projects are shown to have increased impact both during the construction and operations-period of a wind power plant. The extent of increased impact is primarily a function of local ownership and return on investment. As such, policies that prioritize higher levels of local ownership are likely to result in increased economic development impacts. Furthermore, the increased economic development impact of community wind shown here should not be undervalued. As the wind industry grows and approaches penetrations in the U.S. electricity market of 20%, social opposition to new wind power projects may increase. Community wind could provide a valuable strategy for building community support of wind power - especially in communities that are new to wind power. This analysis finds that total employment impacts from completed community wind projects are on the order of four to six 1-year jobs per-MW during construction and 0.3 to 0.6 long-term jobs per-MW during operations. Furthermore, when comparing community wind to hypothetical average absentee projects, construction-period employment impacts are 1.1 to 1.3 times higher and operations-period impacts are 1.1 to 2.8 times higher for community wind. Comparing the average of the completed projects studied here with retrospective analysis of the first 1,000 MW of wind in Colorado and Iowa shows construction-period impacts are as much as 3.1 times higher for community wind, and operations-period impacts are as much as 1.8 times higher. As the wind industry has grown, community wind has largely been a peripheral development model. However, this analysis shows that wind projects are a source of jobs and economic development, and that community wind projects have greater economic development impacts than absentee-owned projects. As such, policies that prioritize higher levels of local ownership are likely to result in increased economic development impacts. While the magnitude of increased benefit is primarily a function of local ownership and project profitability, the increased economic development impact of all community wind projects should not be undervalued. The ability of community wind projects to disperse economic impacts within the states and communities where they are built and to engage local community members in the project could provide a valuable strategy for building community support of wind power especially in communities that are new to wind power.

17 WIND ENERGY↗

Commercially Scalable Process to Fabricate Porous Silicon

Navitas Advanced Solutions Group proposes a novel, commercially scalable approach to supply microporous silicon (μpSi) to lithium ion battery manufacturers. If successful, this project will result in a significant reduction in the cost and environmental impact of high capacity anodes that are needed to meet the EV Everywhere battery goals. Silicon nanocomposite materials have been identified as a viable anode technology for EV batteries. Presently, high capacity silicon-based anodes rely either on materials that are expensive (e. g., silane or nano-silicon powder) or on processes that are limited by low yield methods (e.g., chemical vapor deposition). Microporous silicon potentially avoids these limitations and is attracting increasing attention as a lower cost alternative for the manufacture of high capacity silicon-based anodes. Microporous silicon suitable for EV batteries is not currently available as a commodity material. Microporous silicon can be produced at lab scale through a metal catalyzed hydrofluoric acid etching process. However, this process is expensive and hazardous. Our proposed production route will facilitate the availability of μpSi to lithium ion battery producers and developers at a scale and cost able to support EV battery production. Under the Vehicle Technologies FOA AOI 4 seeks Advances in Existing and Next-Generation Battery Material Manufacturing to reduce the cost of EV batteries. The EV Everywhere initiative establishes a goal of $100/kWh system level cost for an EV battery. This cost target can be met with moderate risk through pairing silicon-based high capacity anodes with lithium metal-rich nickel manganese cobalt oxide 'LMR-NMC' cathodes. For this set of assumptions, the silicon anode active material cost would need to be <$25/kg. The Navitas µpSi powder manufacturing process will reach this target through a combination of low-cost commodity raw materials and reactants with scalable and low environmental impact processes. Processing will involve mechanical milling and thermal reduction operations that are in wide application at industrial scale. The goal of this program is to reach most or all of the MRL 6 criteria in a pilot scale demonstration for the manufacturing of porous silicon powder, while minimizing raw material added cost and limiting hazardous and environmental impact and using scalable industrial processing (i.e. mechanical milling, thermal reduction). The Navitas μpSi fabrication process represents a novel approach to reduce the cost of silicon anode material manufacturing. This process has been shown to be more efficient (higher yield) and economical on scaling up than conventional metal-assisted etching. The process significantly reduces the cost on $/mAh basis versus existing anode materials. The μpSi powders can be modified to form nanocomposite structures through blending with graphite or coating with carbon or a metal oxide to decrease initial capacity loss (ICL) and improve cell cycle life, a key barrier to adoption of silicon anodes into EV batteries. The impact of this technology will be driven by the projected rate of EV adoption and market share. By reducing battery cost, the proposed technology will stimulate EV adoption rate. Assuming this technology enables capturing an additional 6% of the present PHEV + EV market the reduction in petroleum consumption would be 90,000 gallons of gasoline per day, or 1.6M barrels per year. The carbon emissions from a gallon of gasoline = 2.4 kg/gallon. Thus, if the proposed technology was incorporated into just 0.1% of all new vehicles produced and if all the electricity to power those electric-drive vehicles was produced from clean, renewable sources such as wind and solar, it would result in 15K metric tons/yr reduction of CO2 emissions.

25 ENERGY STORAGE↗

Large Solar-Rejection Filter

NASA utilized Image Intensified Video Cameras for ATV data acquisition from a jet flying at 12.8 km. Afterwards the video was digitized and then analyzed with a modified commercial software package, Image Systems Trackeye. Astrometric results were limited by saturation, plate scale, and imposed linear plate solution based on field reference stars. Time-dependent fragment angular trajectories, velocities, accelerations, and luminosities were derived in each video segment. It was evident that individual fragments behave differently. Photometric accuracy was insufficient to confidently assess correlations between luminosity and fragment spatial behavior (velocity, deceleration). Use of high resolution digital video cameras in future should remedy this shortcoming. A scenically accurate description of matter interpreted as a substance made up of corpuscular constituents was established during the course of the 19th century. In this description, atoms--the building blocks of the matter--form molecules. The properties of the molecules were described by chemistry or thermodynamics depending on what characteristics of the matter were investigated. In both theories, the molecules can dissociate to atoms when the kinetic energies of the atoms exceed the strength of the chemical bonds. The number of atoms is always preserved in a closed system. This is not true, however, when the matter takes up much higher energies at relativistic scales. New particles can be produced at the expense of the kinetic energy. The number of particles is no longer preserved. There are other conserved quantities, however, these quantities, the charge, baryon number, lepton number, are associated with particles that are considered elementary today. The properties and behavior of these elementary particles is the subject of Particle Physics or High Energy Physics. Practice Page: A crewmember touching a positively charged surface was thought to be galvanically isolated from the vehicle ground analogous to a bird on a high voltage power wire. Recent analysis confirms that positive floating potentials, ionospheric currents to the EVA suit, can be hazardous. The analysis is wrong in that the ionospheric plasma itself can close the circuit. Parametric analysis of very low voltage exposures (2 to 15 volts) could cause pain and/or involuntary muscle tetani or spinal cord shock. NASA worked with the Naval Health Research Center Detachment Directed Energy Bioeffects Laboratory to examine the affects electrical hazards could have on extravehicular activity using two models. The results of the two computational models were combined to predict areas of the body in which neurons of different diameters would be excited. They predicted that physiologically active current could be conducted across the crew member causing catastrophic hazards. Future work to analyze additional current paths was proposed. The FUSE spectrum of BB Dor, observed in a high state, is modeled with an accretion disk with a very low inclination (possibly lower than 10 degrees). Assuming an average WD mass of 0.8 solar mass leads to a distance of the order of approximately 650pc, consistent with the extremely low galactic reddening in its direction, and a mass accretion rate of 10 (exp -9) solar mass a year. The spectrum presents some broad and deep silicon and sulfur absorption lines, indicating that these elements are over-abundant: silicon is 3 times solar, and sulfur is 20 times solar. The FUSE spectrum of BB Dor, observed in a high state, is modeled with an accretion disk with a very low inclination (possibly lower than 10 degrees). Assuming an average WD mass of 0.8 solar mass leads to a distance of the order of approximately 650pc, consistent with the extremely low galactic reddening in its direction, and a mass accretion rate of 10 (exp -9) solar mass a year. The spectrum presents some broad and deep silicon and sulfur absorption lines, indicating that these elements are over-abundant: silicon is times solar, and sulfur is 20 times solar. From its previously observed optical emission lines, P831-57 (WD 0334 6400 or Ret 1 in A Catalog and Atlas of Cataclysmic Variables: Living Edition) has been suspected to contain an accretion disk associated with a companion star in orbit around a subdwarf star with a temperature T is greater than 21,000K. P831-57 has therefore been classified as a nova-like. However, our present observations show it to be a DA + dMe binary. The analysis of its Far Ultraviolet Spectroscopic Explorer (FUSE) spectrum (continuum and lines) reveal an average mass white dwarf (Log(g) approximately equals 7.8 plus or minus 0.1)with a temperature T approximately equals 37,000 plus or minus 500K, an extremely low projected rotational velocity, and a distance of about 115 plus or minus 5pc. The photosphere contains C, N, Si, and S (at about 1% of solar abundances). The dMe star is seen as a flux excess in near-infrared photometry and appears to show occasional flaring of about one magnitude as seen in the Harvard plates. There is no evidence of periodic variability in the spectroscopic or photometric data. We find no evidence of a an accretion disk, instead we find evidence of wind accretion as the stellar carbon abundance (N(C)/N(H) = 2.5 x 10 (exp -6) is about ten times larger than predicted by radiative levitation for such a gravity and temperature. The power needs and solutions for the space exploration and lunar mobility program are discussed. Long term missions in space and on the lunar surface require high energy batteries. Rechargeable batteries for mobility systems and portable utility pallet are needed for successful exploration missions. Nanomaterial usage increases the energy density of the cells apart from increasing the power density. The symptoms and threats from acute mountain sickness (AMS) are discussed. The underlying assumptions concerning spacecraft atmosphere mean there is a potential risk to astronauts. The baseline worst case scenario is about 25% based on direct ascent to 8.0 psia with 32% O2. The practical mitigation approach is a staged depressurization scheme. Due to the uncertainty about potential AMS risk the flight surgeon should prepare, focused research should proceed, and current analytical efforts should continue. This slide presentation reviews the threat astronauts face from acute mountain sickness (AMS). The incidence of AMS is highly variable and the risk to astronauts is unclear. However, the potential risk is higher than current EAAs suggest and precautions should be implemented. Due to the uncertain nature of the risk flight surgeons should prepare, and focused research should proceed. Quasiparticle tunneling can be understood at low temperatures using a non-equilibrium kinetic theory. Low-temperature tunneling can be suppressed using existing techniques: island-lead gap engineering, lead cooling with SIN junctions, and quasiparticle traps. The slide presentation reviews the science goals and mission planning for the proposed Jupiter System Observer (JSO). The spacecraft would accommodate 9 instruments making the instrument payload more capable than any previously flown to Jupiter. The would-be mission includes study programs for Jupiter's satellites, interior, magnetosphere and atmosphere. The power needs and solutions for the space exploration and lunar mobility program are discussed. Long term missions in space and on the lunar surface require high energy batteries. Rechargeable batteries for mobility systems and portable utility pallet are needed for successful exploration missions. Nanomaterial usage increases the energy density of the cells apart from increasing the power density. This slide presentation reviews the power requirements for the space exploration and the lunar surface mobility programs. It includes information about the specifications for high energy batteries and the power requirements for lunar rovers,

Roberts, William↗

A Review on Protection Challenges on Transmission Lines Connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses. Utilities, university researchers, research institutes, and relay manufacturers have performed studies to investigate different aspects of high IBR penetration. Almost all studies support 1) creating international and national standards to regulate the IBRs, 2) revising engineering tools to address shortcomings, and 3) adjusting the protective relay settings to resolve protection problems. This paper summarizes the studies and research conducted in recent years to quantify the impact of IBR penetration on transmission line protection and to identify potential solutions to improve the dependability and reliability of grid protection systems.

14 SOLAR ENERGY↗

Testing of Liquid Metal Components for Nuclear Surface Power Systems

The Early Flight Fission Test Facility (EFF-TF) was established by the Marshall Space Flight Center (MSFC) to provide a capability for performing hardware-directed activities to support multiple in-space nuclear reactor concepts by using a non-nuclear test methodology. This includes fabrication and testing at both the module/component level and near prototypic reactor configurations. The EFF-TF is currently supporting an effort to develop an affordable fission surface power (AFSP) system that could be deployed on the Lunar surface. The AFSP system is presently based on a pumped liquid metal-cooled (Sodium-Potassium eutectic, NaK-78) reactor design. This design was derived from the only fission system that the United States has deployed for space operation, the Systems for Nuclear Auxiliary Power (SNAP) 10A reactor, which was launched in 1965. Two prototypical components recently tested at MSFC were a pair of Stirling power conversion units that would be used in a reactor system to convert heat to electricity, and an annular linear induction pump (ALIP) that uses travelling electromagnetic fields to pump the liquid metal coolant through the reactor loop. First ever tests were conducted at MSFC to determine baseline performance of a pair of 1 kW Stirling convertors using NaK as the hot side working fluid. A special test rig was designed and constructed and testing was conducted inside a vacuum chamber at MSFC. This test rig delivered pumped NaK for the hot end temperature to the Stirlings and water as the working fluid on the cold end temperature. These test were conducted through a hot end temperature range between 400 to 550C in increments of 50 C and a cold end temperature range from 30 to 70 C in 20 C increments. Piston amplitudes were varied from 6 to 1 1mm in .5 mm increments. A maximum of 2240 Watts electric was produced at the design point of 550 hot end, 40 C cold end with a piston amplitude of 10.5mm. This power level was reached at a gross thermal efficiency of 28%. A baseline performance map was established for the pair of 1kW Stirling convertors. The performance data will then be used for design modification to the Stirling convertors. The ALIP tested at MSFC has no moving parts and no direct electrical connections to the liquid metal containing components. Pressure is developed by the interaction of the magnetic field produced by the stator and the current which flows as a result of the voltage induced in the liquid metal contained in the pump duct. Flow is controlled by variation of the voltage supplied to the pump windings. Under steady-state conditions, pump performance is measured for flow rates from 0.5-4.3 kg/s. The pressure rise developed by the pump to support these flow rates is roughly 5-65 kPa. The RMS input voltage (phase-to-phase voltage) ranges from 5-120 V, while the frequency can be varied arbitrarily up to 60 Hz. Performance is quantified at different loop temperature levels from 50 C up to 650 C, which is the peak operating temperature of the proposed AFSP reactor. The transient response of the pump is also evaluated to determine its behavior during startup and shut-down procedures.

Polzin, Kurt A.↗