Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “water efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Wickability-optimized textured liquid-desiccant air dehumidifiers for independent moisture management in energy-efficient buildings

Liquid-desiccant-based air conditioning systems are envisioned to enable independent humidity management, thereby improving the energy efficiency of future buildings. Existing liquid-desiccant-based air conditioning concepts, however, suffer from a poor liquid flow distribution deteriorating moisture removal rate. They are consequently flooded with the liquid-desiccant solution, which significantly degrades the energy efficiency of the dehumidification process. Here, in this work, the capillary forces and wickability effect of textured air dehumidifier surfaces are altered to minimize the liquid-desiccant flow rate of the fully wetted state, thereby transforming the physics of interfacial desiccant flow distribution. Consequently, the wickability-optimized air dehumidifier surface maximizes both moisture removal rate and dehumidification energy efficiency. It was interestingly found that the length scale of a textured air dehumidifier surface concept is optimized at an intermediate pattern density. Dry solid-air menisci appear at length scales exceeding the optimum pattern distance while the effective liquid–air interfacial area is reduced at smaller length scales, both of which degrade the moisture removal rate. At the optimum pattern density, the effective liquid–air interfacial area increases with the solution flow rate, thereby increasing the dehumidification rate. At a water vapor pressure potential of 3 kPa and a solution flow rate of 2.8 g/s, experimental results indicated a moisture removal rate of 0.16 g/m2-s for a textured surface concept with a capillary length scale of 3 mm, a 28% improvement compared with that of smooth-plate dehumidifier surfaces. A high moisture removal rate of the textured surface at a low desiccant flow rate led to a high thermal efficiency of 0.75 at a water vapor pressure potential of 5.6 kPa and a LiBr flow rate of 2.8 g/s. The insights gained from the present study accelerate the development of advanced textured surface concepts for next-generation liquid-desiccant-based air dehumidification systems offering independent humidity management for future energy-efficient buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of Electromagnetic Fields on Gypsum and Silica Scaling in Reverse Osmosis

Electromagnetic field (EMF) is a cost-effective, simple, and energy-efficient method for scale control in reverse osmosis (RO) systems. However, its effects on gypsum and silica scaling, as well as the underlying mechanisms, remain poorly understood. This study systematically investigates the effects of EMF treatment on gypsum and silica scaling in RO systems, utilizing synthetic brackish water and natural RO concentrate (ROC) from a desalination facility. For gypsum, EMF changes the crystal morphology, resulting in the formation of a porous, less compact scaling layer. It is more readily removed through hydraulic flushing (HF), enhancing scaling reversibility and water recovery. In the case of silica scaling, EMF promotes homogeneous polymerization in the bulk solution, producing larger silica particles that inhibit the formation of a dense, cross-linked gel layer on the membrane surface, mitigating flux decline. This study thus demonstrates EMF’s effectiveness in controlling gypsum scaling in undersaturated feedwaters when combined with HF and in mitigating silica scaling under both HF and non-HF conditions for supersaturated feedwaters. These findings underscore EMF’s versatility as a nonchemical approach for scale control in RO desalination and show its substantial potential to enhance membrane performance and operational efficiency in real-world water treatment applications.

Du, Xuewei [New Mexico State University, Las Cruce↗

FFTSF: Revisiting Sub-Seasonal Streamflow Forecasting with Simple Feedforward Network

Accurate short-to-subseasonal streamflow forecasts are vital for water management, including flood preparedness, drought mitigation, hydropower scheduling, and ecosystem protection. However, extending a forecast beyond a few days remains challenging due to complexity of hydrological processes. While recent self-attention based transformer architectures such as iTransformer have gained traction in time-series forecasting, these models suffer from several critical limitations: (1) significant computational overhead that scales quadratically with sequence length, (2) vulnerability to overfitting on limited hydrological datasets, (3) degraded performance on long-horizon forecasts due to attention decay, and (4) excessive architectural complexity that hampers interpretability and operational deployment. In this study, we propose a simple Feedforward Time Series Forecasting (FFTSF) network that directly addresses these limitations through its lightweight architecture and long-range forecasting capabilities. We evaluate FFTSF across 178 USGS stream gauges spanning diverse climate regimes by forecasting lead times of 1-, 7-, 14-, and 30-days. Our results demonstrate that FFTSF achieves competitive performance at short lead times (NSE of 0.778 for 1-day forecasts) while substantially outperforming complex baselines at longer forecast period, achieving the highest NSE (0.271) at 30-day forecasts with greater robustness and stability. For 30-day forecasts, FFTSF achieves a 71% improvement over NLinear, 57% improvement over DLinear and 12% improvement over the computationally intensive iTransformer while requiring fewer computational resources. Our findings reveal that architectural complexity is not necessary for hydrological forecasting, demonstrating that well-designed simple models can outperform attention mechanisms for subseasonal streamflow forecasting. The computational efficiency and consistent long-range performance of FFTSF make it suitable for water management applications where reliable extended forecasts are essential.

Krishnan Kutty Ambika, Anukesh [ORNL] (ORCID:00000↗

Effects of Surface Terminations of 2D Bi 2 WO 6 on Photocatalytic Hydrogen Evolution from Water Splitting

Two-dimensional (2D)-structured photocatalysts with atomically thin layers not only have the potential to enhance hydrogen generation efficiency but also allow more direct investigations of the effects of surface terminations on photocatalytic activity. In this work, taking 2D Bi 2 WO 6 as a model, we found that the configuration of bilayer Bi 2 O 2 sandwiched by alternating WO 4 layers enabled the thermodynamic driving potential for photocatalytic hydrogen evolution. Without Pt deposition, the H 2 generation efficiency can reach to 56.9 μmol/g/h by 2D Bi 2 WO 6 as compared with no activity of Bi 2 WO 6 nanocrystals under simulated solar light. This configuration is easily functionalized by adsorption of Cl – /Br – to form Bi–Cl/Bi–Br bonds, which leads to the decrease of recombination in photogenerated charge carriers and narrower band gaps. This work highlights an effective way to design photocatalysts with efficient hydrogen evolution by tuning the surface terminations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Monitoring Preferential Flow of Water in Sand Using Thermoacoustics Wave Imaging

Abstract Accurate predictions of fluid flow, mass transport, and reaction rates critically impact the efficiency and reliability of subsurface exploration and sustainable use of subsurface resources. Quantitative dynamical sensing and imaging can play a pivotal role in the ability to make such predictions. Geophysical thermoacoustic technology has the potential to provide the aforementioned capabilities, since it builds upon the principle that electromagnetic and mechanical wave fields can be coupled through a thermodynamic process. In this letter, we present laboratory experiments featuring the efficacy of thermoacoustic imaging in the monitoring of preferential flow of water in porous media. Our laboratory experimental equipment can be readily packaged in a form factor that fits in a borehole, and the use of multiple acoustic transducers—which can be combined with volumetric coding techniques—has the potential to provide quasi‐real‐time imaging (0.5 Hz video rate) of regions in close proximity (a few meters) of an open field well.

Geology↗

Contribution of sewage to occurrence of phosphodiesterase-5 inhibitors in natural water

Phosphodiesterase-5 inhibitors (PDE-5i, such as Sildenafil, Tadalafil and Vardenafil, mainly prescribed to treat erectile dysfunction) and their generic drug equivalents have been widely marketed and consumed in Korea. From the concentrations detected in wastewater, we could deduce that relatively large amounts of PDE-5i were consumed without a legal prescription. Thus, PDE-5i’s presence in the environment via sewage is unavoidable, and their environmental fate within a sewage treatment plant (STP) should be evaluated. In this study, we investigated the occurrence of three PDE-5i analogs in the influent and effluent of two STPs and the receiving water bodies. The PDE-5i concentration in total reached 62 ± 12 (STP#1) and 88 ± 37 ng L -1 (STP#2) in the sewage influent; about 70% of it was Sildenafil in both STPs. However, they were hardly removed by the STPs as the removal efficiency of the STPs was less than 10% ± 5%. Therefore, the pharmaceuticals were detected in the receiving water (lower than 7 ng L -1 as a total amount) and the concentration slightly increased downstream of the STPs. A simple mass balance model applied for the compounds in the STP effluent and receiving water bodies also confirmed that the discharged PDE-5i were quite persistent. Lastly, we identified temporal and regional patterns in the consumption of the drugs from daily variations of PDE-5i in the influent to these two STPs. For instance, the levels of PDE-5i in the sewage significantly increased on weekends (from Friday to Saturday), and especially in the area where adult-entertainment businesses are common. We estimated that the amount of PDE-5i consumption in this area was 31% higher than that in the area with fewer nightlife spots. Considering that they are pharmaceutically active and resistant to treatment processes within an STP, it is advised that a regular monitoring and management program for PDE-5i should be developed to prevent the discharge of the pharmaceuticals into the water environment.

54 ENVIRONMENTAL SCIENCES↗

Condition-Based Maintenance of a Circulating Water System of a Canadian Nuclear Power Plant using Machine Learning and Statistical Tools

Canada Deuterium Uranium pressurized-heavy-water reactors (PHWR) are a type of nuclear power plant that generate clean and reliable energy. The scope of this work is to automate data analysis methodologies to inform a condition-based maintenance strategy of a circulating water system (CWS) of a PHWR. The multiunit CWS provides a continuous supply of water to cool steam condensers, even during transient scenarios, thereby improving the thermal efficiency. This work aims to develop a machine learning (ML) based approach to detect anomalies in heterogeneous data of a CWS in a PHWR to help inform a predictive maintenance strategy. The heterogeneous data include textual and numeric time series data for a PHWR. Natural-language-processing (NLP)-based models are used to analyze textual data contained in work orders and operator logs and an event-timeseries correlation detection method is applied to assist anomalies diagnoses for CWS. An ML model Robust Linear Model (RLM) is also used to remove the seasonal variations in the system variable distributions based on distributions of environmental variables. A machine learning model, Density-Based Spatial Clustering of Applications with Noise (DBSCAN), trained on both original data and data without any seasonal variations will then be used to detect if an anomaly exists. Thus, by moving to an automated methodology to detect, classify, and forecast anomalies, the maintenance strategy would be based on component condition instead of a time-based schedule.

97 - MATHEMATICS AND COMPUTING↗

Interconnection of Aerosol‐Cloud Interactions and Cloud Feedback Through Warm Rain Process

Recent research has revealed a correlation within the Coupled Model Intercomparison Project Phase 6 (CMIP6) simulations: models exhibiting more pronounced warming due to positive cloud feedback simultaneously show enhanced cooling from aerosol‐cloud interactions (ACI). However, the interplay between ACI and cloud feedback is not well understood in these models. Our study addresses this gap by modifying the autoconversion rate in two Earth system models (ESMs), elucidating how ACI could connect with cloud feedback through the warm rain process. We find that higher autoconversion rates, which are associated with stronger ACI, suppress the increase in cloud liquid water path (LWP) and cloud optical depth with warming by enhancing the precipitation efficiency over the extratropical regions, leading to a larger positive cloud feedback. This study offers new insights into the compensatory mechanism between ACI and cloud feedback through the warm rain process and highlights the importance of constraining the autoconversion parameterization in models.

54 ENVIRONMENTAL SCIENCES↗

Low Level Calibration of Liquid Scintillation Counting

Liquid Scintillation Counting (LSC) is an analytical laboratory method that quantifies the concentrations of alpha and beta emitting isotopes. The LSC method can be utilized for the detection of tritium, both environmentally and at nuclear facilities. Most LSC samples are aqueous-based and prepared as a radioactive sample dissolved or suspended in a high efficiency scintillation cocktail that converts radioactive energy into light pulses. When placed in counting vials, the liquid scintillation cocktail allows for optical coupling in which energy is released from the samples radioactive decay, and transferred to the scintillator. That energy is then absorbed to produce excited electrons that fall back to their ground-state and emit a pulse of light that is detected by the liquid scintillation analyzers photomultiplier tubes. Quench is a signal attenuation due to physical, chemical, or color interferences. To compensate for quench, quench standards of a known concentration are implemented at increasing increments of quench per vial to create a quench curve. Quench standards can be purchased pre-made or customized from the manufacturer, however, there are several issues that arise from purchasing the pre-made quench standards. The main issues with ordering pre-made quench standards is that they use higher count values, between 30,000 and 250,000 disintegrations per minute (dpm) of tritium per vial and only come in glass vials. Using higher counting standards in glass vials makes it hard to see lower concentrations in plastic vials. Additionally, when using higher energy standards the accuracy of the calibration readings tend to be lower. On the other hand, making a set of quench standards in-house allows for the customization of the dpm concentration to roughly 1,500-3,000 and preparation in plastic vials. This allows for lower activity readings that results in closer precision of the samples' true concentration. Technical Objectives: Create a quench curve and calibrate the LSA for tritium. Verify the calibration of the quench curve prior to cross sample runs. Check calibration against Quality Control (QC) reference value. Conclusion: a tritium quench curve calibration was performed using a scintillation cocktail with ultima gold (AB and AB/F), acetone (only with AB), and water (only with AB/F). By performing the tritium quench curve calibration, the counting efficiency was correlated to various levels of quench. Calibration checks with quality control standards were also performed to verify that the calibration was correct. The observed results provided acceptable values that matched the quality control standard reference values with an acceptable uncertainty. The next step will be fine tuning and cross comparison checks with legacy instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A ModEx Framework for Watershed Subsurface Investigation With Limited Geophysical Data Using Machine Learning and Hydrologic Modeling

Abstract Subsurface heterogeneity influences watershed hydrology strongly but remains difficult to characterize at catchment scales with sparse and costly field data. Geophysical surveys such as electromagnetic induction (EMI) provide local spatial subsurface images yet scaling them to watershed scales and converting EMI‐derived resistivity into hydraulic properties remains a challenge. We present a Model–Experiment (ModEx) framework that integrates limited EMI data with machine learning (ML) and hydrologic modeling to improve process representation and guide field investigations. Sparse EMI surveys were scaled to the catchment scale using a Random Forest model, and the resulting resistivity fields were combined with nearby borehole constraints to parameterize a hydrologic model. The EMI‐informed hydrological simulations improved predictions of streamflow sustained by subsurface flow and shallow saturation patterns. By combining EMI data and ML with hydrologic modeling, the ModEx framework guides future subsurface surveys, providing a transferable and efficient strategy for data–model integration across diverse watersheds. Plain Language Summary Mapping the underground network of soil and rock that controls water is essential for predicting floods and droughts, but seeing underground is difficult and expensive. We cannot drill everywhere, so scientists use geophysical tools to scan broad areas. There are two key challenges: these geophysical scans are often sparse across the whole watershed, and the geophysical data is hard to translate into water‐related properties. We used artificial intelligence to solve these problems. We taught a computer to find patterns linking the limited geophysical data to the land surface properties. This allowed it to fill in the gaps and create a complete, useful subsurface map for the entire watershed. This new map improves hydrologic simulations, leading to more accurate predictions of water movement in the watershed. It also helps scientists build better models with less data and generates a priority map showing where to measure next, making future investigations more efficient. Key Points Limited EMI scaled with ML improves catchment‐scale subsurface parameterization for hydrologic models The framework integrates hydrologic modeling with limited geophysical data to support subsurface investigation design ModEx framework offers a transferable data–model integration strategy that quantifies and reduces uncertainty guiding watershed studies

Chen, Hang↗

Using an Isotope Enabled Mass Balance to Evaluate Existing Land Surface Models

Abstract Land surface models (LSMs) play a crucial role in elucidating water and carbon cycles by simulating processes such as plant transpiration and evaporation from bare soil, yet calibration often relies on comparing LSM outputs of landscape total evapotranspiration ( ET ) and discharge with measured bulk fluxes. Discrepancies in partitioning into component fluxes predicted by various LSMs have been noted, prompting the need for improved evaluation methods. Stable water isotopes serve as effective tracers of component hydrologic fluxes, but data and model integration challenges have hindered their widespread application. Leveraging National Ecological Observation Network measurements of water isotope ratios at 16 US sites over 3 years combined with LSM‐modeled fluxes, we employed an isotope‐enabled mass balance framework to simulate ET isotope values ( δET ) within three operational LSMs (Mosaic, Noah, and VIC) to evaluate their partitioning. Models simulating δET values consistent with observations were deemed more reflective of water cycling in these ecosystems. Mosaic exhibited the best overall performance (Kling‐Gupta Efficiency of 0.28). For both Mosaic and Noah there were robust correlations between bare soil evaporation fraction and error (negative) as well as transpiration fraction and error (positive). We found the point at which errors are smallest ( x ‐intercept of the multi‐site regression) is at a higher transpiration fraction than is currently specified in the models. Which means that transpiration fraction is underestimated on average. Stable isotope tracers offer an additional tool for model evaluation and identifying areas for improvement, potentially enhancing LSM simulations and our understanding of land‐surface hydrologic processes.

58 GEOSCIENCES↗

Advanced Fuels Campaign Time-at-Temperature Irradiation Campaign and Post-Irradiation Examination Plan

With increasing per capita energy consumption and rapidly growing energy consumption predicted for data centers, the US faces challenges in meeting projected energy demands. The current administration is attempting to accelerate the deployment of new nuclear construction by providing significant investments in advanced nuclear and by modernizing regulatory approaches for the licensing new reactors. However, enabling extended power uprates (EPUs) for the current nuclear reactor fleet would provide a shorter-term solution to better calibrate near-term energy generation capacity to the ever-growing energy demands of the modern era. One pathway to achieve power uprates is to increase the operational window by reassessing fuel safety limits around anticipated transients. Existing light-water reactors (LWRs) utilize a targeted operational window with well-defined operational efficiencies, yet this window is also often bound by conservative safety limits that result in suboptimal operational performance. For example, the operation of the existing fleet is highly constrained by safeguards to operation related to anticipated operational occurrences (AOOs), which are moderate-frequency transients expected with a frequency greater than 0.01 per reactor-year. These AOOs include temperature excursions where the critical heat flux for the system is exceeded, resulting in a departure from nucleate boiling (DNB) at the cladding surface. This DNB event is a thermohydraulic condition that, with current conservative fuel safety limits, results in the fuel rods being classified as “failed,” meaning that the cladding may not be returned to service.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ice-slurry production for solar-ice systems using supercooling with an in-stream crystallizer

Using ice slurry produced from supercooled water with an in-stream crystallizer opens a new path for solarice systems, increasing efficiency and reducing investment cost compared to ice-on-coil systems. Power needs are decoupled from the stored energy since the heat exchangers are not evenly distributed in the ice storage vessel but directly placed as the heat pump evaporator, which depends on the heat pump capacity and not on the ice storage volume. The novel ice storage design can serve as a heat source for a heat pump, where its evaporator is used to supercool water below 0 °C, or for refrigeration. The supercooled water at a temperature around −2 °C, maintained in a meta-stable liquid state, is triggered to nucleate in an in-stream crystallizer. The current design of the ice crystallizer allows for continuous operation of the system and scalability. Experimental results obtained with a gasketed plate heat exchanger used to supercool water and an in-stream crystallizer operated at a power of up to 6.5 kW are presented.

Thamm, Ann-Katrin↗

Intrinsically Conductive {pi}‑d Conjugated Layers with Co–N4 Active Sites for Efficient Nitrate Electrocatalysis and Zinc-Nitrate Batteries

Electrochemical synthesis of ammonia from nitrate has been extensively investigated as a potential alternative to the energy-intensive Haber-Bosch process. This approach not only operates under ambient conditions but also simultaneously removes nitrate contaminants while producing ammonia as a value-added product. However, the ongoing quest lies in designing an efficient electrocatalyst that achieves a high ammonia yield rate, high selectivity, and long-term stability. Herein, we report the outstanding performance of a Co–N4 coordinated π-d layered Co3(HITP)2 (HITP = 2,3,6,7,10,11-hexaiminotriphenylene) in nitrate electrocatalysis. The unique combination of abundant Co–N4 active sites and superior electrical conductivity enables significant electrocatalytic activity, delivering a maximum ammonia yield rate of 56.8 mg cm–2 h–1 at −0.8 V vs RHE and a Faradaic efficiency of ∼91% at −0.4 V vs RHE. Mechanistic analysis reveals that alkaline conditions accelerate water dissociation to generate adsorbed hydrogen intermediates (H*), which are utilized by Co–N4 sites to drive the stepwise hydrogenation of nitrate to ammonia while suppressing competing hydrogen evolution reaction (HER) pathways. Furthermore, integration of this catalyst into a zinc-nitrate battery resulted in a maximum power density of 5.3 mW cm–2 and an open-circuit potential of ∼1.45 V. These results highlight the potential of π-d conjugated Co–N4 materials as an efficient catalyst for both environmental remediation and energy conversion.

Namvar, shahrirar↗

Energy Analysis of Combi Heat Pump System Configurations for Space Conditioning and Domestic Hot Water Heating in Residential Buildings

Combi heat pump systems, also referred to multifunctional variable refrigerant flow heat recovery (MF-VRFHR) systems, are specifically designed for residential applications to manage both space conditioning and domestic hot water (DHW). They have attracted attention due to their potential for energy conservation through heat recovery. The incorporation of a hot water tank introduces various system configurations, each characterized by distinct pros and cons related to energy efficiency, system stability, and maintenance. Despite this, a critical gap exists as the specific energy performance remains unquantified under diverse operational modes (e.g., heating mode and heat recovery mode). This paper aims to bridge this gap by conducting a comprehensive comparative analysis of two prevalent system configurations while considering feasible proposed control logics. Configuration 1 integrates a separate hot water tank and a refrigerant-to-water heat exchanger (HEX), also known as a Hydro Kit while Configuration 2 incorporates a refrigerant-wrapped hot water tank. To facilitate this analysis, we developed high-fidelity system models for both configurations in Modelica, capturing system dynamics and detailed control sequences effectively. These system models were built upon the TIL library for HVAC equipment components and the Buildings library for residential building thermal load calculations. The validation of the simulation testbed utilized data from experiments conducted in the PNNL lab home for Configuration 1. To establish the simulation testbed for Configuration 2, we extended the modeling setup derived from Configuration 1. This extension specifically involved substituting the separate hot water tank and Hydro Kit with a refrigerant-wrapped hot water tank of similar sizing sourced from an actual product. The simulation analysis of heating-only and heat recovery modes reveals that Configuration 2 not only saves energy and maintains warmer tank temperatures but also demonstrates faster water heating capabilities. This is attributed to decreased energy loss and improved heat transfer. The study encompasses a wide range of scenarios, considering diverse thermal loads and water usage patterns across heating and heat recovery modes. Overall, the comprehensive results indicate that Configuration 2 achieves energy savings ranging from 3.5% to 12.2% compared to Configuration 1, depending on factors such as water usage patterns, thermal loads, and operational modes.

Configuration, Comparison, Multi-functional, Resid↗

System design and analysis of thermal power dispatch systems for boiling water reactors

Nuclear power plants are crucial to meeting net zero emission goals and achieving energy sustainability. Integrating these plants with clean energy technologies such as high-temperature steam electrolysis (HTSE) may improve the efficiency and economic competitiveness of these plants. Here, the current study investigates the design and operation of a thermal power dispatch (TPD) system for coupling boiling water reactors (BWRs) to HTSE plants. The TPD system extracts a portion of the steam from the reactor’s main steam line and transfers its thermal energy to an HTSE plant through a power transport loop. A TPD system for 5 % steam extraction has been designed and the system performance during steady and transient operations has been analyzed. The TPD system dispatched a total of 197 MW thermal energy to the HTSE plant under nominal design conditions. Saturated steam at 7.17 MPa from the BWR plant was condensed and subcooled to a temperature of 168 °C, while a mass flow rate of 91.1 kg/s of superheated steam was dispatched to the HTSE plant. Furthermore, the system performance during transient operation showed a continuous transition from the initial hot standby mode to the nominal power dispatch level. The transient simulation results emphasized the importance of investigating component level performance for the TPD system design. The current results will guide future works on the development of integrated energy systems for hydrogen production or process heat applications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

UV/chlorine advanced oxidation processes for degradation of contaminants in water and wastewater: A comprehensive review

Advanced oxidation processes (AOPs) have recently gained increasing attention as promising alternatives to conventional water and wastewater treatment technologies. As an AOP, there has been a growing interest in UV/chlorine due to its multiple disinfection modes and ability to maintain chlorine residuals in drinking water distribution systems. Compared to the popular UV/H 2 O 2 AOP treatment process, UV/chlorine AOP possesses several advantages including a higher radical production efficiency and a lower power demand. The process has recently been applied for the degradation of a wide range of natural and synthetic organic as well as inorganic compounds including pharmaceutical and personal care products, natural organic matter, herbicides and insecticides, taste and odor, and different types of water and wastewaters. The focus of the present work is to review and evaluate the efficiency of the UV/chlorine process on the oxidation of these pollutants. Here a critical overview is provided of the fundamentals of UV/chlorine, controlling factors of the process performance, and a comparison with other UV-based AOPs. The formation of disinfection by-products (DBPs), one of the concerns associated with UV/chlorine treatment, is discussed and strategies to tackle this obstacle are provided for future studies and applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗