Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “uncertainty estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Introducing an Absolute Cavity Pyrgeometer (ACP) for Improving the Atmospheric Longwave Irradiance Measurement (Poster)

Advancing climate change research requires accurate and traceable measurement of the atmospheric longwave irradiance. Current measurement capabilities are limited to an estimated uncertainty of larger than +/- 4 W/m2 using the interim World Infrared Standard Group (WISG). WISG is traceable to the Systeme international d'unites (SI) through blackbody calibrations. An Absolute Cavity Pyrgeometer (ACP) is being developed to measure absolute outdoor longwave irradiance with traceability to SI using the temperature scale (ITS-90) and the sky as the reference source, instead of a blackbody. The ACP was designed by NREL and optically characterized by the National Institute of Standards and Technology (NIST). Under clear-sky and stable conditions, the responsivity of the ACP is determined by lowering the temperature of the cavity and calculating the rate of change of the thermopile output voltage versus the changing net irradiance. The absolute atmospheric longwave irradiance is then calculated with an uncertainty of +/- 3.96 W/m2 with traceability to SI. The measured irradiance by the ACP was compared with the irradiance measured by two pyrgeometers calibrated by the World Radiation Center with traceability to the WISG.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Predicting Reactor Antineutrino Emissions Using New Precision Beta Spectroscopy

Neutrino experiments at nuclear reactors are currently vital to the study of neutrino oscillations. The observed antineutrino rates at reactors are typically lower than model expectations. This observed deficit is called the “reactor neutrino anomaly”. A new understanding of neutrino physics may be required to explain this deficit, though model estimation uncertainties may also play a role in the apparent discrepancy. PNNL is currently investigating an experimental technique that promises reduced uncertainties for measured data to support these hypotheses and interpret reactor antineutrino measurements. The experimental approach is to 1) direct a proton accelerator beam on a metal target to produce a source of neutrons, 2) use spectral tailoring to modify the neutron spectrum to closely simulate the energy distribution of a power reactor neutron spectrum, 3) irradiate isotopic fission foils (235U, 238U, 239Pu, 241Pu) in this neutron spectrum so that fissions occur at energies representative of a reactor, 4) transport the beta particles released by the fission products in the foils to a beta spectrometer, 5) measure the beta energy spectrum, and 6) invert the measured beta energy spectrum to an antineutrino energy spectrum. A similar technique using a beta spectrometer and isotopic fission foils was pioneered in the 1980’s at the ILL thermal reactor. Those measurements have been the basis for interpreting all subsequent antineutrino measurements at reactors. A basic constraint in efforts to reduce uncertainties in predicting the antineutrino emission from reactor cores is any underlying limitation of the original measurements. This may include beta spectrum energy resolution, the absolute normalization of beta emission to number of fission, statistical counting uncertainties, lack of 238U data, the purely thermal nature of the IIL reactor neutrons used, etc. An accelerator-based neutron source that can be tailored to match various reactor neutron spectra provides an advantage for control in studying how changes in the neutron spectra (i.e. "in the reactor core") affects the resulting fission product beta spectrum. Furthermore, the 238U antineutrino spectrum, which has not been measured, can be studied directly because of the enhanced 1 MeV fast neutron flux available at the accelerator source. A facility such as the Project X Injector Experiment (PXIE) 30 MeV proton linear accelerator at Fermilab is being considered for this experiment. The hypothesis is that a new approach utilizing the flexibility of an accelerator neutron source with spectral tailoring coupled with a careful design of an isotopic fission target and beta spectrometer and the inversion of the beta spectrum to the neutrino spectrum will allow further reduction in the uncertainties associated with prediction of the reactor antineutrino spectrum.

Asner, David M.↗

Measuring Broadband IR Irradiance in the Direct Solar Beam (Poster)

Solar and atmospheric science radiometers, e.g. pyranometers, pyrheliometers, and photovoltaic cells are calibrated with traceability to a consensus reference, which is maintained by Absolute Cavity Radiometers (ACRs). The ACR is an open cavity with no window, developed to measure extended broadband direct solar irradiance beyond the ultraviolet and infrared bands below and above 0.2 micrometers and 50 micrometers, respectively. On the other hand, pyranometers and pyrheliometers are developed to measure broadband shortwave irradiance from approximately 0.3 micrometers to 3 micrcometers, while the present photovoltaic cells are limited to approximately 0.3 micrometers to 1 micrometers. The broadband mismatch of ACR versus such radiometers causes discrepancy in radiometers' calibration methods that has not been discussed or addressed in the solar and atmospheric science literature. Pyrgeometers are also used for solar and atmospheric science applications and calibrated with traceability to consensus reference, yet calibrated during nighttime only, because no consensus reference has yet been established for the daytime longwave irradiance. This poster shows a method to measure the broadband IR irradiance in the direct solar beam from 3 micrometers to 50 micrometers, as first step that might be used to help develop calibration methods to address the mismatch between broadband ACR and shortwave radiometers, and the lack of a daytime reference for pyrgeometers. The irradiance was measured from sunrise to sunset for 5 days when the sun disk was cloudless; the irradiance varied from approximately 1 Wm-2 to 16 Wm-2 for solar zenith angle from 80 degres to 16 degrees respectively; estimated uncertainty is 1.5 Wm-2.

47 OTHER INSTRUMENTATION↗

Measuring Broadband IR Irradiance in the Direct Solar Beam (Presentation)

Solar and atmospheric science radiometers, e.g. pyranometers, pyrheliometers, and photovoltaic cells are calibrated with traceability to a consensus reference, which is maintained by Absolute Cavity Radiometers (ACRs). The ACR is an open cavity with no window, developed to measure extended broadband direct solar irradiance beyond the ultraviolet and infrared bands below and above 0.2 um and 50um, respectively. On the other hand, pyranometers and pyrheliometers are developed to measure broadband shortwave irradiance from approximately 0.3 um to 3 um, while the present photovoltaic cells are limited to approximately 0.3 um to 1 um. The broadband mismatch of ACR versus such radiometers causes discrepancy in radiometers' calibration methods that has not been discussed or addressed in thesolar and atmospheric science literature. Pyrgeometers are also used for solar and atmospheric science applications and are calibrated with traceability to consensus reference, yet are calibrated during nighttime only, because no consensus reference has yet been established for the daytime longwave irradiance. This poster shows a method to measure the broadband IR irradiance in the direct solarbeam from 3 um to 50 um, as a first step that might be used to help develop calibration methods to address the mismatch between broadband ACR and shortwave radiometers, and the lack of a daytime reference for pyrgeometers. The irradiance was measured from sunrise to sunset for 5 days when the sun disk was cloudless; the irradiance varied from approximately 1 Wm-2 to 16 Wm-2 for solar zenithangle from 80 degrees to 16 degrees respectively; estimated uncertainty is 1.5 Wm-2.

14 SOLAR ENERGY↗

Measuring Broadband IR Irradiance in the Direct Solar Beam and Recent Developments

Solar and atmospheric science radiometers such as pyranometers, pyrheliometers, and photovoltaic cells are calibrated with traceability to a consensus reference which is maintained by Absolute Cavity Radiometers (ACRs). An ACR is an open cavity with no window, developed to measure the extended broadband spectrum of the terrestrial direct solar beam irradiance that extends beyond the ultraviolet and infrared bands; i.e. below 0.2 um and above 50 um, respectively. On the other hand, the pyranometers and pyrheliometers were developed to measure broadband shortwave irradiance from approximately 0.3 um to 3 um, while the present photovoltaic cells are limited to the spectral range of approximately 0.3 um to 1 um. The broadband mismatch of ACR versus such radiometers causes discrepancy in radiometers' calibration methods that has not been discussed or addressed in the solar and atmospheric science literature. Pyrgeometers, which measure the atmospheric longwave irradiance, are also used for solar and atmospheric science applications and calibrated with traceability to a consensus reference, yet they are calibrated during nighttime only, because no consensus reference has been established for the daytime longwave irradiance. This poster describes a method to measure the broadband longwave irradiance in the terrestrial direct solar beam from 3 um to 50 um, as a first step that might be used to help develop calibration methods to address the mismatch between broadband ACR and shortwave radiometers, and the lack of a daytime reference for pyrgeometers. The described method is used to measure the irradiance from sunrise to sunset; the irradiance varied from approximately 1 Wm-2 to 16 Wm-2 with an estimated uncertainty of 1.5 Wm-2, for a solar zenith angle range from 80 degrees to 16 degrees, respectively. Recent development shows that there is greater than 1.1 percent bias in measuring shortwave solar irradiance.

14 SOLAR ENERGY↗

Introducing an Absolute Cavity Pyrgeometer (ACP) for Improving the Atmospheric Longwave Irradiance Measurement (Poster)

Advancing climate change research requires accurate and traceable measurement of the atmospheric longwave irradiance. Current measurement capabilities are limited to an estimated uncertainty of larger than +/- 4 W/m2 using the interim World Infrared Standard Group (WISG). WISG is traceable to the Systeme international d'unites (SI) through blackbody calibrations. An Absolute Cavity Pyrgeometer(ACP) is being developed to measure absolute outdoor longwave irradiance with traceability to SI using the temperature scale (ITS-90) and the sky as the reference source, instead of a blackbody. The ACP was designed by NREL and optically characterized by the National Institute of Standards and Technology (NIST). Under clear-sky and stable conditions, the responsivity of the ACP is determined bylowering the temperature of the cavity and calculating the rate of change of the thermopile output voltage versus the changing net irradiance. The absolute atmospheric longwave irradiance is then calculated with an uncertainty of +/- 3.96 W/m2 with traceability to SI. The measured irradiance by the ACP was compared with the irradiance measured by two pyrgeometers calibrated by the WorldRadiation Center with traceability to the WISG.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of Heterogeneity Effects on Calculated Sensitivities of the ZPPR-15B Assemblies

In past years, sensitivity studies of ZPR and ZPPR assemblies were carried out with deterministic codes for several purposes, such as uncertainty estimation of calculated parameter values, cross section adjustment, representativity analysis. etc. However, these sensitivity studies used simplified R-Z models of ZPR/ZPPR assemblies where the multi-group cross section data was obtained from the homogenized material compositions of each reactor zone. The main reason for this simplification was the lack of a deterministic path able to compute sensitivity coefficients for complicated 3D geometries in transport theory. Also, each ZPR and ZPPR assembly consists of several different drawers each containing different plate types and plate arrangements and it was felt that performing sensitivity calculations with an equivalent R-Z reactor model would capture most of the feedback while the heterogeneity effects were believed to be of second order. Recently a new code, BuildZPRModel, was developed at ANL that automatically generates the inputs for cross section processing and core calculation of heterogeneous ZPR and ZPPR assemblies for 3D transport calculations. Additionally, the PERSENT code (recently developed at ANL as well) is able to carry out sensitivity calculations in transport theory on 3D geometries. With the benefit of the newly developed codes, a sensitivity study was performed for the heterogeneous model of ZPPR-15B assemblies 96 and 102 generated by BuildZPRModel. The results were compared with the sensitivities computed with the use of fully homogenized R-Z reactor models, in order to quantify the impact of heterogeneity effects neglected in the analysis performed in past years.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Using Whisper-1.1 to Guide Improvements to Nuclear Data Evaluations [Slides]

This presentation covers the use of Whisper-1.1 to guide improvements to nuclear data evaluations. This presentation provides a brief overview on what Whisper-1.1 is. Additionally covered is the benchmark selection: using benchmark and application correlations (ck) computed using nuclear data sensitivity profiles and covariance data. Next the presentation touches on compute bias and bias uncertainty based on selected benchmarks using Extreme Value Theory Finally the presentation shows the additional margin for nuclear data uncertainty estimated by GLLS.

97 MATHEMATICS AND COMPUTING↗

Detection Identification and Quantification of Keto-Hydroperoxides in Low-Temperature Oxidation.

Keto-hydroperoxides are reactive partially oxidized intermediates that play a central role in chain-branching reactions during the low-temperature oxidation of hydrocarbons. In this Perspective, we outline how these short lived species can be detected, identified, and quantified using integrated experimental and theoretical approaches. The procedures are based on direct molecular-beam sampling from reactive environments, followed by mass spectrometry with single-photon ionization, identification of fragmentation patterns, and theoretical calculations of ionization thresholds, fragment appearance energies, and photoionization cross sections. Using the oxidation of neo-pentane and tetrahydrofuran as examples, the individual steps of the experimental approaches are described in depth together with a detailed description of the theoretical efforts. For neo-pentane, the experimental data are consistent with the calculated ionization and fragment appearance energies of the keto-hydroperoxide, thus adding confidence to the analysis routines and the employed levels of theory. For tetrahydrofuran, multiple keto-hydroperoxide isomers are possible due to the presence of nonequivalent O 2 addition sites. Despite this additional complexity, the experimental data allow for the identification of two to four keto-hydroperoxides. Mole fraction profiles of the keto-hydroperoxides, which are quantified using calculated photoionization cross sections, are provided together with estimated uncertainties as function of the temperature of the reactive mixture and can serve as validation targets for chemically detailed mechanisms.

Hansen, Nils↗

Establishing the World Reference for Measuring the Atmospheric Longwave Irradiance with Traceability to the International System of Units

Advancing climate change research requires accurate and traceable measurement of the atmospheric longwave irradiance. Current measurement capabilities are limited to an estimated uncertainty of larger than +/- 6 W/ m2 using the interim World Infrared Standard Group (WISG). Two independently designed and calibrated absolute radiometers measuring downwelling longwave irradiance were compared during five outdoor comparisons in 2013, 2015, and 2017 at the Physikalisch Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC) and the USA-DOE Atmospheric Radiation Measurement program (ARM) in the Southern Great Planes (SGP). Two Absolute Cavity Pyrgeometers (ACPs) developed by the National Renewable Energy Laboratory (NREL) and four Integrating Sphere Infrared Radiometers (IRISs) developed by PMOD/WRC took part in these intercomparisons. From five comparisons, the difference between the irradiance measured by the ACPs and IRISs varied from 0.2 W/ m2 to 2.5 W/ m2 based on the atmospheric conditions, which is within the combined stated uncertainties of +/-3 W/ m2. The irradiance measured by the WISG is lower than the average irradiance measured by ACPs and IRISs, magnitude of the difference varied from 0.2 W/m2 to 6.6 W/ m2 depending on the integrated water vapor. A concerted effort at the World Meteorological Organization (WMO) Commission for Instruments and Methods of Observation Commission (CIMO) Task Team on Radiation References (TT) started during a meeting from November 15 to 17, 2017 in the National Physical Laboratory (NPL), Teddington, United Kingdom to establish a world reference for measuring the atmospheric longwave irradiance with lower uncertainty and with traceability to SI units by using the ACPs and IRISs as the reference.

14 SOLAR ENERGY↗

Establishing the World Reference for Measuring the Atmospheric Longwave Irradiance with Traceability to the International System of Units

Advancing climate change research requires accurate and traceable measurement of atmospheric longwave irradiance. Measurement capabilities are limited to an estimated uncertainty of larger than +/- 6 W/m2 using the interim World Infrared Standard Group (WISG). Two independently designed and calibrated absolute radiometers measuring downwelling longwave irradiance were compared during five outdoor comparisons in 2013, 2015, and 2017 at the Physikalisch Meteorologisches Observatorium Davos World Radiation Center (PMOD/WRC) and the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement program (ARM) in the Southern Great Planes (SGP). Two Absolute Cavity Pyrgeometers (ACPs) developed by the National Renewable Energy Laboratory (NREL) and four Integrating Sphere Infrared Radiometers (IRISs) developed by PMOD/WRC took part in these intercomparisons.From the five comparisons, the difference between the irradiance measured by ACPs and IRISs varied from 0.2 W/m2 to 2.5 W/m2 based on atmospheric conditions, which is within the combined stated uncertainties of +/- 3 W/m2. The irradiance measured by the WISG is lower than the average irradiance measured by ACPs and IRISs. The magnitude of difference varied from 0.2 W/m2 to 6.6 W/m2 depending on the integrated water vapor. A concerted effort to establish a world reference for measuring the atmospheric longwave irradiance with lower uncertainty and with traceability to the International System of Units (SI) by using the ACPs and IRISs as the reference started at the World Meteorological Organization (WMO). The Commission for Instruments and Methods of Observation Commission (CIMO) Task Team on Radiation References (TT) meeting was held in 2017 at the National Physical Laboratory (NPL), in Teddington, United Kingdom to discuss specific recommendation on the traceability of the atmospheric longwave irradiance to the International System of units (SI).

14 SOLAR ENERGY↗

List-Mode source injection algorithm for detectors with arbitrary pose and trajectory

environments, introducing actual sources is usually neither feasible nor economical. It is more practical to move the detector (whether airborne, vehicle-borne, or human-portable) through the test environment and then later artificially superimpose either measured or simulated source signatures on the recorded background data. We present a source injection (SI) algorithm that inserts source events into list-mode background data. It is designed to accommodate cases where “injection data” are available only at a limited set of locations. Stochastic methods are employed both to select source events from a measured dataset containing both source and background events, and to scale the number of selected events to match the field conditions of detector-source distance, air attenuation, acquisition duration, and the relative strength of the measured and injected sources. The algorithm is deployed as part of the Airborne Radiation Enhanced-sensor System (ARES) Advanced Technology Demonstration, and is applied to field data obtained using the ARES detector system. For this helicopter-borne detection system, we describe a practical ground-based measurement scheme for acquiring data for later injection. These data are then injected into background data acquired during flight, where arbitrary detector poses and trajectories are possible. Similar flight paths are traversed with and without actual 137Cs and 60Co sources present. SI is applied to the source-absent datasets, and the results are compared to the source-present datasets. SI output is found to be consistent with measured activity within the estimated uncertainties in GPS position and source strength.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of $d^2 \sigma/d|\vec{q}|d E_{avail}$ and 2p2h contribution using charged current $\nu_\mu$ interactions in the NOvA Near Detector

This Thesis presents the analysis methods and measurement of the $d^2 \sigma/d|\vec{q}|d E_{avail}$-CC inclusive cross section that describes neutrino scattering in a predominantly hydrocarbon medium. Studies that are prerequisite for the analysis including, variable determinations, event selections, efficiency, purity determinations, and systematic uncertainty estimations, are summarized. Tests of the analysis are also detailed, and shown to reproduce the input distributions. The double-differential cross-section measurement provides the foundation for determination of the inclusive rate for the excess induced by 2p2h processes together with nuclear medium effects that are not described by the Fermi gas model. The methodology for the extraction of this rate, defined as the excess observed relative to the rate estimated for known single-nucleon interactions, is described in detail. The following new measurements are reported in this Thesis: (1) The $\nu_\mu-$CC inclusive double-differential cross section as a function of three-momentum transfer and available hadronic energy, for an average $E_\nu$ of 1.8 GeV, is obtained. The double-differential cross section value that obtains when the bin widths are taken to be the dimensions of the entire analysis domain, e.g. $0.2 \le |\vec{q}| \le 2.0 GeV/c$ and $0.0 \le E_{avail} \le 2.0$ GeV, is inclusive cross section is $(6.05 \pm 0.75)\times10^{-39}$ cm$^2$/GeV/GeV/$c$/nucleon. An event excess attributed to 2p2h-MEC processes is observed; most of the rate occurs in a contiguous phase space region $0.3 \le |\vec{q}| \le 1.0$ GeV$/c$ $0.0 \le E_{avail} \le 0.35$ GeV. This rate represents $12.0\pm 6.5\%$ of the observed CC inclusive cross section; its cross section ratio relative to CCQE scattering is estimated to be $44.3 \pm 23.9\%$.

Olson, Travis Grant↗

Analyzing the Calibration History of Radiometers for Determining Optimal Calibration Day(s)

This study investigates the effects of calibrating radiometers using one day or multiple cloudless days as recommended by ASTM and ISO standards. The results demonstrate good responsivity agreement with estimated uncertainty error bars over the years for various radiometers under various Broadband Outdoor Radiometer Calibration (BORCAL) events at both the National Renewable Energy Laboratory and the Southern Great Plains facility. The BORCAL method appears to justify the use of a single calibration day with enough data points to attain repeatable calibration results.

BORCAL↗

Application of State and Federal Guidelines for Establishing Alternate Soil Clean-Up Levels for the Protection of Groundwater at the Hanford Site

Risk-based soil cleanup levels that are protective of groundwater have been calculated for use in environmental remediation activities at the Hanford Site using vadose zone fate and transport modeling. The determination of soil cleanup levels is important because it involves the technical basis for the levels of contamination that can be left in place, which are protective of human health and the environment. The determination of risk-based soil cleanup levels is an especially important issue at the Hanford Site where site conditions such as a semi-arid climate, and a thick vadose zone of over 100 meters necessitate the use of appropriate risk-based methods. In the absence of an alternative risk-based approach, the cleanup levels default to background, detection limits, or simplistic formulas not intended for applications involving these distinctive site conditions. However, the use of vadose zone fate and transport modeling for risk-based applications such as the determination of soil cleanup levels in the vadose zone are not as well established as modeling for groundwater applications. Thus, the use of models in this manner involves additional challenges for the demonstration of the efficacy of its use for risk-based applications, in accordance with federal and state regulatory requirements and guidelines. An approach has been developed to integrate with federal and state regulatory guidelines in conjunction with the development of the risk-based methodology. Demonstration of integration with these guidelines primarily involves documentation of the objectives of the problem to be solved, the technical basis and rationale associated with the selection of an appropriate risk-based method (e.g., model type and code selection), and documentation associated with the use of the model, e.g., conceptual site model, parameter estimation, uncertainty and assumptions analyses, and model results. (authors)

54 ENVIRONMENTAL SCIENCES↗

Validation of nuclear design method by measured data obtained in the physics test at a small fast reactor

The present paper discusses applicability of the measured data of Joyo cores from a view point of integral validation for the 4S nuclear design methodology. Through the evaluation of isothermal reactivity coefficients and reactivity losses due to burnup, the results confirm that those MK-I and MK-II database are effective in order to increase the dataset for uncertainty estimation for the prediction. Discussions on the 4S design method validation are also done through the analyses of criticality, power distributions and reactivity loss due to burn-up. The C/E values for criticality and reaction rate distributions are confirmed to be consistent with those obtained from the physics benchmark experiments. Through an analysis of burnup coefficient of the MK-I core by the detailed Monte Carlo calculations, the C/E value is 1.1, which is close to 1.06 obtained by the deterministic transport analysis. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Upgrade and Certification of the Los Alamos National Laboratory SHENC 2011 - 12270

Nondestructive assay measurements of Transuranic (TRU) waste at Los Alamos National Laboratory (LANL) required the addition of a standard waste box (SWB) assay system. A Super High Efficiency Neutron Counter (SHENC) located at Hanford was identified to be relocated to LANL. After careful evaluation of waste streams at LANL, it was determined that the current configuration of the SHENC was not sufficient to quantify certain waste streams. At LANL, there is still a large amount of waste that needs to be retrieved and repackaged within SWB's to meet agreements with the State of New Mexico. Prior to relocating the SHENC, the only assay systems available were High Efficiency Neutron Counters having only a 55-gallon drum capacity. Further analyses indicated that the SHENC system should be capable of quantitative gamma measurements that are to be linked, and combined, with the neutron measurements. The SHENC system was therefore augmented with a new high-resolution gamma spectroscopy system using BE5030 detectors and upgraded gamma electronics. The neutron side of the system was also upgraded with an advanced shift register (JSR-15), an improved Programmable Logic Controller and NDA-2000 software. This report will include calibration of both the neutron and gamma modalities of the SHENC system and how the modality results are combined to produce a single assay result. Preliminary performance results will be discussed based on both mock and real waste measurements. Discussions will also include a complete description of the adjustable parameters as well as the calibration plan, techniques and validations including calibration confirmation based on the Waste Isolation Pilot Plant Waste Acceptance Criteria (WIPP-WAC). The SHENC was successfully upgraded to efficiently measure the complex waste streams at Los Alamos National Laboratory. A new PLC was successfully added to the system for Add-A-Source control. A new shift register was added to the SHENC (JSR-15) which provides more flexibility if replacement is required. The addition of the density based calibration on the gamma modality of the system increases the effectiveness of the SHENC for high alpha-n producing waste. Upgrading the system to new software also helped to standardize the program at Los Alamos. Only one new procedure was initiated for the integration of the SHENC. Add-A-Source measurements were effectively integrated with the system based on the confirmation results and positive results during two Department of Energy Performance Demonstration Program Box Cycles. Total measurement uncertainty estimates were completed for both the gamma modality and the neutron modality of the system. The SHENC was reviewed by both the Department of Energy and the Environmental Protection Agency in 2011. The certification letter for the SHENC was issued on November 16, 2011. With the certification letter issued to the Central Characterization Project the SHENC can perform waste measurements on SWB's at Los Alamos for shipment to WIPP. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Why Use Geo-statistics For Nuclear Decommissioning Projects? - 15567

Before nuclear facilities are dismantled, and contaminated sites remediated, their initial radiological state must be characterized. Combining historical information, non-destructive measurements and lab analysis results, the statistical method of geo-statistics allows all available data for 2D or 3D contamination mapping to be integrated and enhanced, and helps quantify estimation uncertainties. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗