Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “timing detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Fatigue-Crack-Tip Locator

Fatigue-testing system includes automated subsystem continuously tracking location of fatigue-crack tip in metal or other highly electrically conductive specimen. Fatigue-crack-tip-locating subsystem also searches specimen to find initial fatigue crack and its tip and to trace out hidden fatigue cracks and other flaws inside specimen. Subsystem operates under overall control of personal computer, which also controls load frame applying prescribed cyclic stresses to specimen. Electromagnetic flaw detector based on eddy-current principle scanned over surface of specimen. Flaw detector described in "Electromagnetic Flaw Detector Is Easier To Use" (LAR-15046). System provides automated control and monitoring of fatigue experiments, saving time for researchers and enabling experiments to run unattended 24 hours a day. All information on crack-tip trajectories and rates of growth of cracks recorded automatically, so researchers have access to more information.

Namkung, Min↗

The new MTLRS-1 receiving system

In this report, we are giving a detailed description of the new receiving system of the German Modular Transportable Laser Ranging System MTLRS-1, consisting of a spectral time and field of view filter and a Single Photon Avalanche Diode (SPAD) as a single photon detector. The system gives full day and night ranging capability to all satellites with cm accuracy.

Sperber, Peter↗

Development and applications of laser-induced incandescence

Several NASA-funded investigations focus on soot processes and radiative influences of soot in diffusion flames given their simplicity, practical significance, and potential for theoretical modeling. Among the physical parameters characterizing soot, soot volume fraction, f(sub v), a function of particle size and number density, is often of chief practical interest in these investigations, as this is the geometrical property that directly impacts radiative characteristics and the temperature field of the flame and is basic to understanding soot growth and oxidation processes. Diffusion flames, however, present a number of challenges to the determination of f(sub v) via traditional extinction measurements. Laser-induced incandescence (LII) possesses several advantages compared to line-of-sight extinction techniques for determination of f(sub v). Since LII is not a line-of-sight technique, similar to fluorescence, it possesses geometric versatility allowing spatially resolved measurements of f(sub v) in real time in nonaxisymmetric systems without using deconvolution techniques. The spatial resolution of LII is determined by the detector and imaging magnification used. Neither absorption by polycyclic aromatic hydrocarbons (PAH's) nor scattering contributes to the signal. Temporal capabilities are limited only by the laser pulse and camera gate duration, with measurements having been demonstrated with 10 ns resolution. Because of these advantages, LII should be applicable to a variety of combustion processes involving both homogeneous and heterogeneous phases. Our work has focussed on characterization of the technique as well as exploration of its capabilities and is briefly described.

Vanderwal, Randy L.↗

BATSE Solar Flare Spectroscopy

This final report describes the progress originally proposed: (1) the continued improvement of a software and database environment capable of supporting all users of BATSE solar data as well as providing scientific expertise and effort to the BATSE solar community; (2) the continued participation with the PI team and other guest investigators in the detailed analysis of the BATSE detectors' response at low energies; (3) using spectroscopic techniques to fully exploit the potential of electron time-of-flight studies; and, (4) a full search for flare gamma-ray line emission at 2.2 MeV from all GOES X-class flares observed with BATSE.

Schwartz, R. A.↗

ISO Key Project: Exploring the Full Range of Quasar/AGN Properties

The ISOPHOT team have developed new recommendations for observing faint sources with ISHPOHT which involve small rasters rather than chopping. This was finalized around Feb 1997 and following this we re-designed the observations for the remainder of our observing time. We had put our program on hold in September when it became clear that chopped observations had major problems. The revised program, which included re-observation at long wavelengths using rasters for a number of high-priority targets and re-specification of new observations of others, was released in April 1997. The latest prediction for the satellite lifetime has extended its life until April 1998. Our project has been allocated a 15% increase in our observing time as a result of this life extension. We are currently working on setting priorities in order to determine which targets to include in this additional time. This will help to offset some of the targets lost due to the significant decrease in detector sensitivity over pre-flight predictions.

Wilkes, Belinda J.↗

Cloud Thickness from Diffusion of Lidar Pulses in Clouds

Measurements of the distribution of reflected light from a laser beam incident on an aqueous suspension of particles or "cloud" with known thickness and particle size distribution are reported. The distribution is referred to as the "cloud radiative Green's function", G. In the diffusion domain, G is sensitive to cloud thickness, allowing that important quantity to be retrieved. The goal of the laboratory simulation is to provide preliminary estimates of sensitivity of G to cloud thickness,for use in the optimal design of an offbeam Lidar instrument for remote sensing of cloud thickness (THOR, Thickness from Offbeam Returns). These clouds of polystyrene microspheres suspended in water are analogous to real clouds of water droplets suspended in air. The microsphere size distribution is roughly lognormal, from 0.5 microns to 25 microns, similar to real clouds. Density of suspended spheres is adjusted so mean-free-path of visible photons is about 10 cm, approximately 1000 times smaller than in real clouds. The light source is a ND:YAG laser at 530 nm. Detectors are flux and photon-counting Photomultiplier Tube (PMTS), with a glass probe for precise positioning. A Labview 5 VI controls positioning, and data acquisition, via an NI Motion Control board connected to a stepper motor driving an Edmund linear slider, and a 16-channel 16-bit NI-DAQ board. The stepper motor is accurate to 10 microns, and step size is selectable from the VI software. Far from the incident beam, the rate of exponential increase as the direction of the incident beam is approached scales as expected from diffusion theory, linearly with the cloud thickness, and inversely as the square root of the reduced optical thickness, and is independent of particle size. Near the beam the signal begins to increase faster than exponential, due to single and low-order scattering near the backward direction, and here the distribution depends on particle size. Results are being used to verify 3D Monte Carlo radiative transfer simulations, used to estimate signal-to-noise ratios for remotely sensed off beam returns, for both homogeneous and inhomogeneous clouds. Signal-to-noise estimates show that unfiltered observations are straight forward at night, while narrow band pass filters are being studied for day.

Cahalan, Robert F.↗

Diffuse Reflection of Laser Light From Clouds

Laser light reflected from an aqueous suspension of particles or "cloud" with known thickness and particle size distribution defines the "cloud radiative Green's function", G. G is sensitive to cloud thickness, allowing retrieval of that important quantity. We describe a laboratory simulation of G, useful in design of an offbeam Lidar instrument for remote sensing of cloud thickness. Clouds of polystyrene microspheres suspended in water are analogous to real clouds of water droplets suspended in air. The size distribution extends from 0.5 microns to 25 microns, roughly lognormal, similar to real clouds. Density of suspended spheres is adjusted so photon mean-free-path is about 10 cm, 1000 times smaller than in real clouds. The light source is a Nd:YAG laser at 530 nm. Detectors are flux and photon-counting PMTs, with a glass probe for precise positioning. A Labview 5 VI controls position and data acquisition, via an NI Motion Control board connected to a stepper motor driving an Edmund linear slider,and a 16-channel 16-bit NI-DAQ board. The stepper motor is accurate to 10 microns. Step size is selectable. Far from the beam, the rate of exponential increase in the beam direction scales as expected from diffusion theory, linearly with cloud thickness, and inversely as the square root of the reduced optical thickness, independent of particle size. Nearer the beam the signal increases faster than exponential and depends on particle size. Results verify 3D Monte Carlo simulations that demonstrate detectability of remotely sensed offbeam returns, without filters at night, with narrow bandpass filter in day.

Cahalan, R. F.↗

Initial Performance of the Aspect System on the Chandra Observatory: Post-Facto Aspect Reconstruction

The aspect system of the Chandra Observatory plays a key role in realizing the full potential of Chandra's x-ray optics and detectors. To achieve the highest spatial and spectral resolution (for grating observations), an accurate post-facto time history of the spacecraft attitude and internal alignment is needed. The CXC has developed a suite of tools which process sensor data from the aspect camera assembly and gyroscopes, and produce the spacecraft aspect solution. In this poster, the design of the aspect pipeline software is briefly described, followed by details of aspect system performance during the first eight months of flight. The two key metrics of aspect performance are: image reconstruction accuracy, which measures the x-ray image blurring introduced by aspect; and celestial location, which is the accuracy of detected source positions in absolute sky coordinates.

Aldcroft, T.↗

Measurements of n-p correlations in the reaction of relativistic neon with uranium

We report a preliminary measurement of coincident neutron-proton pairs emitted at 45 degrees in the interaction of 400, 530, and 650 MeV/A neon beams incident on uranium. Charged particles were identified by time of flight and momentum, as determined in a magnetic spectrometer. Neutral particles were detected using a thick plastic scintillator, and their time of flight was measured between an entrance scintillator, triggered by a charged particle, and the neutron detector. The scatter plots and contour plots of neutron momentum vs. proton momentum appear to show a slight correlation ridge above an uncorrelated background. The projections of this plane on the n-p momentum difference axis are essentially flat, showing a one standard deviation enhancement for each of the three beams energies. At each beam energy, the calculated momentum correlation function for the neutron-proton pairs is enhanced near zero neutron-proton momentum difference by approximately one standard deviation over the expected value for no correlation. This enhancement is expected to occur as a consequence of the attractive final state interaction between the neutron and proton (i.e., virtual or "singlet" deuterons). The implications of these measurements are discussed.

NASA Program Space Medicine↗

Microaltimeter

A microaltimeter measures altitude or range highly accurately from an orbiting vehicle. The microaltimeter has a low power solid state laser that is pulsed at a rate above 1 kilohertz. The pulses are delivered to a small telescope which sends them to a planetary surface and receives return reflections. A high efficiency photon detector measures received photons and supplies received photon signals to a process or which makes a time-based bin-wise comparison to find the time of flight and hence the range.

Degnan, John J↗

LIGO-VIRGO Triggered Follow-Up with NASA High Energy Photon Survey Missions

We discuss the proposed use of LIGO-VIRGO S6 triggers from comparatively loud events to search for both prompt and afterglow EM counterparts with RXTE, SWIFT and FERMI. Using a 2 or 3-fold coincident trigger from the two LIGO and one VIRGO detectors to provide sky position information, we can search the data from these missions within a limited time window and a constrained portion of their respective FOVs, allowing us to look at a level below the threshold normally used to publicly indicate an event. Since we propose to use these missions in their survey mode, no re-pointing of the missions is envisioned. The search for a coincidence between the data from LIGO-VIRGO and the EM survey missions can then be analyzed off-line; if a coincident EM signal is found it would have a significant effect in establishing the validity of the GW trigger. We discuss some relevant aspects of the NASA missions and give some preliminary estimates of thresholds and coincident background rates.

Camp, Jordan↗

MoonBEAM: A Beyond Earth-Orbit Gamma-Ray Burst Detector for Multi-Messenger Astronomy

MoonBEAM is a 12U CubeSat concept of deploying gamma-ray detectors in cislunar space to increase gamma-ray burst detections and improve localization precision with the timing triangulation technique. Such an instrument would probe the extreme processes in cosmic collision of compact objects and facilitate multi-messenger time-domain astronomy to explore the end of explore the end of stellar life cycles and black hole formation.

Beyond Earth-Orbit↗

MoonBEAM: A Beyond Earth-orbit Gamma-ray Burst Detector for Multi-Messenger Astronomy

MoonBEAM is a SmallSat concept of deploying gamma-ray detectors in cislunar space to increase gamma-ray burst detections and improve localization precision with the timing triangulation technique. Such an instrument would probe the extreme processes involved in the cosmic collision of compact objects and facilitate multi-messenger time-domain astronomy to explore the end of explore the end of stellar life cycles and black hole formation.

Hui, Chiumun M.↗

Status of direct detector and array development

Programs are now underway to develop and demonstrate the detector/array technology needed for the Space Infrared Telescope Facility (SIRTF), Large Deployable Reflector (LDR), and other future NASA missions. The development goal is to achieve focal plane sensitivities, at extended integration times over the 2 to 700 microns range, limited only by the low astrophysical backgrounds encountered in cryogenic telescopes such as SIRTF. Dramatic progress has been made in the last 2 to 3 years in integrated array and detector systems for low background astronomical applications. With the broadly based developments and lab characterizations now underway for SIRTF and similar space applications, coupled with the rapidly expanding art and science of ground based astronomical imagery with arrays, the potential for effective utilization of arrays with LDR appears to be very good.

Mccreight, Craig R.↗

Monitoring of inventory in enclosed turbulent liquid tanks using floating gamma-ray sources

An accurate and simple technique utilizing a low-intensity gamma-ray source floating in a vertical tube, whose configuration is tank geometry and size dependent, is shown to eliminate the disturbing effects of turbulent fluid on enclosed tank liquid inventory measurement. The vertical tube aligns the source with detectors positioned outside of the tank, and collapses the turbulent liquid surface to a true average level. The exit attenuation of the information carrying high energy gamma rays is insensitive to liquid surface tubulence, and sensing probe penetrations are not necessary. It is found that for a half-full tank, 1.0 percent statistical error, and 1-s measuring times, that a 220 C Ce-137 source is required for an 8-ft high tank. Consistent experimental results are found for the dual detector method, and results indicate that the accuracy of the scanning side detector method is dependent on the quality of the collimator and degree of lower level energy discrimination.

Klein, R. M.↗

AZW-LA-II White Paint on Swift: Lessons Learned from First Time Flying on Spacecraft Radiators

AZ-Tek's AZW-LA-II low solar absorptance white paint was previously flown as a flight experiment, and is being flown as a calorimeter. However it has never been flown as a thermal coating of radiators on an operational spacecraft before. This paint has the lowest solar absorptance among all white paints, and a very small degradation. Its cost is many times more expensive than white paints that have a higher solar absorptance. To meet the thermal requirements of the Swift Burst Alert Telescope (BAT) Detector Array and X-Ray Telescope (XRT) focal plane camera assembly (FPCA) charged coupled device (CCD), AZW-LA-II is used as the thermal coating for the BAT and XRT radiators. This paper presents the lessons learned from flying this low solar absorptance white paint as a thermal coating of radiators on an operational spacecraft for the first time.

Choi, Michael K.↗

An Ultrasensitive Hot-Electron Bolometer for Low-Background SMM Applications

We are developing a hot-electron superconducting transition-edge sensor (TES) that is capable of counting THz photons and operates at T = 0.3K. The main driver for this work is moderate resolution spectroscopy (R approx. 1000) on the future space telescopes with cryogenically cooled (approx. 4 K) mirrors. The detectors for these telescopes must be background-limited with a noise equivalent power (NEP) approx. 10(exp -19)-10(exp -20) W/Hz(sup 1/2) over the range v = 0.3-10 THz. Above about 1 THz, the background photon arrival rate is expected to be approx. 10-100/s), and photon counting detectors may be preferable to an integrating type. We fabricated superconducting Ti nanosensors with a volume of approx. 3x10(exp -3) cubic microns on planar substrate and have measured the thermal conductance G to the thermal bath. A very low G = 4x10(exp -14) W/K, measured at 0.3 K, is due to the weak electron-phonon coupling in the material and the thermal isolation provided by superconducting Nb contacts. This low G corresponds to NEP(0.3K) = 3x10(exp -19) W/Hz(sup 1/2). This Hot-Electron Direct Detector (HEDD) is expected to have a sufficient energy resolution for detecting individual photons with v > 0.3 THz at 0.3 K. With the sensor time constant of a few microseconds, the dynamic range is approx. 50 dB.

bolometers↗

IDE spatio-temporal impact fluxes and high time-resolution studies of multi-impact events and long-lived debris clouds

During the first 12 months of the Long Duration Exposure Facility (LDEF) mission, the Interplanetary Dust Experiment (IDE) recorded over 15,000 total impacts on six orthogonal faces with a time resolution on the order of 15 to 20 seconds. When combined with the orbital data and the stabilized configuration of the spacecraft, this permits a detailed analysis of the micro-particulate environment. The functional status of each of the 459 detectors was monitored every 2.4 hours, and post-flight analyses of these data has now permitted an evaluation of the effective active detection area as a function of time, panel by panel and separately for the two sensitivity levels. Thus, total impacts were transformed into areal fluxes, and are presented here for the first time. Also discussed are possible effects of these fluxes on previously announced results: apparent debris events, meteor stream detections, and beta meteoroids in observationally significant numbers.

Mulholland, J. Derral↗