Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “testing statistics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

A Preliminary Measurement of the Longitudinal Spin Asymmetry An1*

To date, measurements of the nucleon-virtual photon longitudinal spin asymmetry $A_1$ for both the proton and neutron have shown that the extracted helicity dependent-to-independent ratio of the down-quark parton distribution functions in the proton, $\Delta d/d$, tends towards -1/3 at large $x$, in disagreement with the perturbative QCD prediction that $\Delta d/d$ should approach unity. As part of Jefferson Lab experiment E06-014 performed in Hall A, double-spin asymmetries were measured when scattering a longitudinally polarized electron beam of energies 4.73 and 5.89 GeV from a longitudinally and transversely polarized $^3$He target in the deep inelastic scattering region, allowing for the extraction of the neutron asymmetry $A_1^n$. We will discuss the analysis of our data and present preliminary results for the nuclear asymmetry $A_1^{^3\textrm{He}}$ and $A_1^{n}$ in the kinematic range of $0.2 < x < 0.65$ and $2 < Q^2 < 5$ GeV$^2$ for the scattered electrons. Our measurement of $A_1^{n}$ will provide a test of previous results with a higher statistical precision and continuous coverage of the $x$ range above.

Flay, David↗

Neutrino Program at Fermilab - Enhancing Proton Beam Power and Accelerator Infrastructure

The upcoming long baseline neutrino experiments aim to enhance proton beam power to multi-MW scale and utilize large-scale detectors to address the challenge of limited event statistics. The DUNE experiment at LBNF will test the three neutrino flavor paradigm and directly search for CP violation by studying oscillation signatures in the high intensity $\nu_{\mu}$ (anti-$\nu_{\mu}$) beam to $\nu_e$ (anti-$\nu_e$) measured over a long baseline.\par Higher beam power and improved accelerator up-time will enhance neutrino flux for the neutrino program by increasing the number of protons on target. LBNF/DUNE, as well as PIP-II upgrade and Accelerator Complex Evolution (ACE) plan, play a vital role in this effort. The scientific potential of ACE plan extends beyond neutrino physics, encompassing endeavors such as the Muon Collider, Charged Lepton Flavor Violation (CLFV), Dark Sectors, and exploration of neutrinos beyond DUNE. In the era of higher-power accelerator operation, research in target materials and beam instrumentation is crucial for optimizing design modifications. This abstract discusses Fermilab ACE, the science opportunities it provides, and how Fermilab is pushing the limits of proton beam power and accelerator infrastructure. By tackling neutrino beam challenges and exploring research and development ideas, we are advancing our understanding of fundamental particles and their interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutrino Program at Fermilab -- Enhancing proton beam power and accelerator infrastructure

The upcoming long baseline neutrino experiments aim to enhance proton beam power to multi-MW scale and utilize large-scale detectors to address the challenge of limited event statistics. The DUNE experiment at LBNF will test the three neutrino flavor paradigm and directly search for CP violation by studying oscillation signatures in the high intensity $\nu_{\mu}$ (anti-$\nu_{\mu}$) beam to $\nu_{e}$ (anti-$\nu_{e}$) measured over a long baseline. Higher beam power and improved accelerator up-time will enhance neutrino flux for the neutrino program by increasing the number of protons on target. LBNF/DUNE, as well as PIP-II upgrade and Accelerator Complex Evolution (ACE) plan, play a vital role in this effort. The scientific potential of ACE plan extends beyond neutrino physics, encompassing endeavors such as the Muon Collider, Charged Lepton Flavor Violation (CLFV), Dark Sectors, and exploration of neutrinos beyond DUNE.\par In the era of higher-power accelerator operation , research in target materials and beam instrumentation is crucial for optimizing design modifications. This abstract discusses Fermilab ACE, the science opportunities it provides, and how Fermilab is pushing the limits of proton beam power and accelerator infrastructure. By tackling neutrino beam challenges and exploring research and development ideas, we are advancing our understanding of fundamental particles and their interactions.

43 PARTICLE ACCELERATORS↗

Enhanced climate reproducibility testing with false discovery rate correction

Simulating the Earth's climate is an important and complex problem, thus climate models are similarly complex, comprised of millions of lines of code. In order to appropriately utilize the latest computational and software infrastructure advancements in Earth system models running on modern hybrid computing architectures to improve their performance, precision, accuracy, or all three; it is important to ensure that model simulations are repeatable and robust. This introduces the need for establishing statistical or non-bit-for-bit reproducibility, since bit-for-bit reproducibility may not always be achievable. Here, we propose a short-simulation ensemble-based test for an atmosphere model to evaluate the null hypothesis that modified model results are statistically equivalent to that of the original model. We implement this test in version 2 of the US Department of Energy's Energy Exascale Earth System Model (E3SM). The test evaluates a standard set of output variables across the two simulation ensembles and uses a false discovery rate correction to account for multiple testing. The false positive rates of the test are examined using re-sampling techniques on large simulation ensembles and are found to be lower than the currently implemented bootstrapping-based testing approach in E3SM. We also evaluate the statistical power of the test using perturbed simulation ensemble suites, each with a progressively larger magnitude of change to a tuning parameter. The new test is generally found to exhibit more statistical power than the current approach, being able to detect smaller changes in parameter values with higher confidence.

Kelleher, Michael E. [Oak Ridge National Laborator↗

Characterization of U.S. Wave Energy Converter (WEC) Test Sites: A Catalogue of Met-Ocean Data, 2nd Edition

This report presents met-ocean data and wave energy characteristics at eight U.S. wave energy converter (WEC) test and potential deployment sites. Its purpose is to enable the comparison of wave resource characteristics among sites as well as the selection of test sites that are most suitable for a developer's device and that best meet their testing needs and objectives. It also provides essential inputs for the design of WEC test devices and planning WEC tests, including the planning of deployment, and operations and maintenance. For each site, this report catalogues wave statistics recommended in the International Electrotechnical Commission Technical Speci cation (IEC 62600-101 TS) on Wave Energy Characterization, as well as the frequency of occurrence of weather windows and extreme sea states, and statistics on wind and ocean currents. It also provides useful information on test site infrastructure and services.

16 TIDAL AND WAVE POWER↗

Characterization of U.S. Wave Energy Converter (WEC) test sites: a catalogue of met-ocean data (Second edition)

This report presents met-ocean data and wave energy characteristics at eight U.S. wave energy converter (WEC) test and potential deployment sites. Its purpose is to enable the comparison of wave resource characteristics among sites as well as the selection of test sites that are most suitable for a developer’s device and that best meet their testing needs and objectives. It also provides essential inputs for the design of WEC test devices and planning WEC tests, including the planning of deployment, and operations and maintenance. For each site, this report catalogues wave statistics recommended in the International Electrotechnical Commission Technical Specification (IEC 62600-101 TS) on Wave Energy Characterization, as well as the frequency of occurrence of weather windows and extreme sea states, and statistics on wind and ocean currents. It also provides useful information on test site infrastructure and services.

16 TIDAL AND WAVE POWER↗

Evaluation of Field-Mapping Data for the MI-Tech MI-506CE-1 Compact-Range Reflector in the Sandia National Laboratories' Facility for Antenna and Radar-cross-section Measurements (FARM)

The compact range, located at the Sandia National Laboratories Facility for Antenna and Radar-cross-section Measurements (FARM), has been upgraded by the addition of a new, larger reflector. The new reflector, an MI Technologies model MI-506CE-1, was installed and tested during August through October of 2013. Extensive field mapping was performed by MI Tech personnel, and that data is presented and examined here. Statistics describing the field quality are provided for the nominal test zone, as well as several reduced-size test zones. Spatial-frequency analysis has been applied to the data, and this process allows a determination of amplitude and direction information associated with unwanted reflected and diffracted field components arriving in the test zone.

42 ENGINEERING↗

Tools for Water Ingress Testing

The Safety Storage and Engineering Team, as part of the Production Support Services division (PSS-2), is tasked with ensuring the safety of containers used for handling and storage of nuclear materials. As part of this work, water ingress tests are conducted to evaluate the water-tightness of containers intended for in-glovebox use. In collaboration, the statistics group of the Computer and Computational Sciences Division (CCS-6) provided support in developing a statistically defensible approach for determining appropriate sample sizes for water ingress testing. Water ingress testing involves multiple measurements on multiple containers. Our approach uses a simple random effects model to analyze a pilot data set, implementing prediction limits to evaluate the efficacy of collecting additional data. Although this study capitalizes on available data, our approach can be used with estimates of the ratio of between and within variability and average values, often available from past testing or expert knowledge. An interactive Shiny tool was developed as a final user-friendly product for future testing. The Shiny interface is an open-source package providing a framework for building web applications. Raw data exploration and prediction interval-based sample size assessments can quickly be conducted by the engineering team without needing to interact with the underlying code.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Safety and Efficacy of Radiation Therapy in Advanced Melanoma Patients Treated With Ipilimumab

Purpose: Ipilimumab and radiation therapy (RT) are standard treatments for advanced melanoma; preclinical models suggest the potential for synergy. However, limited clinical information exists regarding safety and optimal timing of the combination. Methods and Materials: We reviewed the records of consecutive patients with unresectable stage 3 or 4 melanoma treated with ipilimumab. Patients were categorized as having received RT or not. Differences were estimated between these 2 cohorts. Results: We identified 88 patients treated with ipilimumab. At baseline, the ipilimumab-plus-RT group (n=44) had more unfavorable characteristics. Despite this, overall survival, progression-free survival, and both immune-related and non–immune-related toxicity were not statistically different (P=.67). Patients who received ipilimumab before RT had an increased duration of irradiated tumor response compared with patients receiving ipilimumab after RT (74.7% vs 44.8% at 12 months; P=.01, log-rank test). In addition, patients receiving ablative RT had non–statistically significantly improved median overall survival (19.6 vs 10.2 months), as well as 6-month (95.1% vs 72.7%) and 12-month (79.7% vs 48.5%) survival rates, compared with those treated with conventionally fractionated RT. Conclusions: We found that both ablative and conventionally fractionated RT can be safely administered with ipilimumab without a clinically apparent increase in toxicity. Patients who received ipilimumab before RT had an increased duration of irradiated tumor response.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deformation and fracture characteristics of zirconium plate produced via ultrasonic additive manufacturing

Abstract The microstructural evolution, deformation modes, and fracture mechanisms of zirconium plate produced using ultrasonic additive manufacturing (UAM) are presented. In addition to conventional tensile testing techniques, digital image correlation captured highly variable strain accumulation in specimens loaded perpendicular or parallel to the build height (Z). When tested in parallel to Z, delamination at prior foil/foil interfaces creates strain localization noticeable in strain rate maps, whereas specimens loaded perpendicular to Z illustrate conventional strain hardening until necking accelerates delamination. Although bond strengths are statistically and spatially variable, in situ electron backscattering diffraction tests illustrate the ability for grains near interfaces to accommodate strain with twinning and slip modes consistent with conventionally produced zirconium alloys. Finally, mixtures of ductile and delamination-induced fracture highlight the interface-driven failure modes of UAM zirconium plate in the as-built condition. Graphic abstract

36 MATERIALS SCIENCE↗

Liver segmentation in contrast enhanced CT data using graph cuts and interactive 3D segmentation refinement methods

Purpose: Liver segmentation is an important prerequisite for the assessment of liver cancer treatment options like tumor resection, image-guided radiation therapy (IGRT), radiofrequency ablation, etc. The purpose of this work was to evaluate a new approach for liver segmentation. Methods: A graph cuts segmentation method was combined with a three-dimensional virtual reality based segmentation refinement approach. The developed interactive segmentation system allowed the user to manipulate volume chunks and/or surfaces instead of 2D contours in cross-sectional images (i.e, slice-by-slice). The method was evaluated on twenty routinely acquired portal-phase contrast enhanced multislice computed tomography (CT) data sets. An independent reference was generated by utilizing a currently clinically utilized slice-by-slice segmentation method. After 1 h of introduction to the developed segmentation system, three experts were asked to segment all twenty data sets with the proposed method. Results: Compared to the independent standard, the relative volumetric segmentation overlap error averaged over all three experts and all twenty data sets was 3.74%. Liver segmentation required on average 16 min of user interaction per case. The calculated relative volumetric overlap errors were not found to be significantly different [analysis of variance (ANOVA) test, p = 0.82] between experts who utilized the proposed 3D system. In contrast, the time required by each expert for segmentation was found to be significantly different (ANOVA test, p = 0.0009). Major differences between generated segmentations and independent references were observed in areas were vessels enter or leave the liver and no accepted criteria for defining liver boundaries exist. In comparison, slice-by-slice based generation of the independent standard utilizing a live wire tool took 70.1 min on average. A standard 2D segmentation refinement approach applied to all twenty data sets required on average 38.2 min of user interaction and resulted in statistically not significantly different segmentation error indices (ANOVA test, significance level of 0.05). Conclusions: All three experts were able to produce liver segmentations with low error rates. User interaction time savings of up to 71% compared to a 2D refinement approach demonstrate the utility and potential of our approach. The system offers a range of different tools to manipulate segmentation results, and some users might benefit from a longer learning phase to develop efficient segmentation refinement strategies. The presented approach represents a generally applicable segmentation approach that can be applied to many medical image segmentation problems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deep Learning Experiments for Tropical Cyclone Intensity Forecasts

Reducing tropical cyclone (TC) intensity forecast errors is a challenging task that has interested the operational forecasting and research community for decades. To address this, we developed a deep learning (DL)-based multilayer perceptron (MLP) TC intensity prediction model. The model was trained using the global Statistical Hurricane Intensity Prediction Scheme (SHIPS) predictors to forecast the change in TC maximum wind speed for the Atlantic basin. In the first experiment, a 24-h forecast period was considered. To overcome sample size limitations, we adopted a leave one year out (LOYO) testing scheme, where a model is trained using data from all years except one and then evaluated on the year that is left out. When tested on 2010–18 operational data using the LOYO scheme, the MLP outperformed other statistical–dynamical models by 9%–20%. Additional independent tests in 2019 and 2020 were conducted to simulate real-time operational forecasts, where the MLP model again outperformed the statistical–dynamical models by 5%–22% and achieved comparable results as HWFI. The MLP model also correctly predicted more rapid intensification events than all the four operational TC intensity models compared. In the second experiment, we developed a lightweight MLP for 6-h intensity predictions. When coupled with a synthetic TC track model, the lightweight MLP generated realistic TC intensity distribution in the Atlantic basin. Therefore, the MLP-based approach has the potential to improve operational TC intensity forecasts, and will also be a viable option for generating synthetic TCs for climate studies.

58 GEOSCIENCES↗

SU-F-T-392: Superior Brainstem and Cochlea Sparing with VMAT for Glioblastoma Multiforme

Purpose: Volumetric arc therapy (VMAT) can provide similar target coverage and normal tissue sparing as IMRT but with shorter treatment times. At our institution VMAT was adopted for the treatment glioblastoma multiforme (GBM) after a small number of test plans demonstrated its non-inferiority. In this study, we compare actual clinical treatment plans for a larger cohort of patients treated with either VMAT or IMRT. Methods: 90 GBM patients were included in this study, 45 treated with IMRT and 45 with VMAT. All planning target volumes (PTVs) were prescribed a dose of 50 Gy, with a simultaneous integrated boost to 60 Gy. Most IMRT plans used 5 non-coplanar beams, while most VMAT plans used 2 coplanar beams. Statistical analysis was performed using Fisher’s exact test or the Wilcoxon-Mann-Whitney rank sum test. Included in the analysis were patient and treatment characteristics as well as the doses to the target volumes and organs at risk. Results: Treatment times for the VMAT plans were reduced by 5 minutes compared with IMRT. The PTV coverage was similar, with at least 95% covered for all plans, while the median boost PTV dose differed by 0.1 Gy between the IMRT and VMAT cohorts. The doses to the brain, optic chiasm, optic nerves and eyes were not significantly different. The mean dose to the brainstem, however, was 9.4 Gy less with VMAT (p<0.001). The dose to the ipsilateral and contralateral cochleae were respectively 19.7 and 9.5 Gy less (p<0.001). Conclusion: Comparison of clinical treatment plans for separate IMRT and VMAT cohorts demonstrates that VMAT can save substantial treatment time while providing similar target coverage and superior sparing of the brainstem and cochleae. To our knowledge this is the first study to demonstrate this benefit of VMAT in the management of GBM.

60 APPLIED LIFE SCIENCES↗

Dense Accumulation of Lipiodol Emulsion in Hepatocellular Carcinoma Nodule during Selective Balloon-occluded Transarterial Chemoembolization: Measurement of Balloon-occluded Arterial Stump Pressure

Purpose. To reveal the mechanism of dense accumulation of lipiodol emulsion (LE) in hepatocellular carcinoma (HCC) during selective balloon-occluded transarterial chemoembolization (B-TACE). Methods. Balloon-occluded arterial stump pressure (BOASP) at the embolization portion was measured during selective B-TACE for 43 nodules in 42 patients. Fluoroscopy and digital subtraction angiography were prospectively observed during selective B-TACE to note whether dense LE accumulation in HCC occurred. The LE concentration ratio of HCC to embolized liver parenchyma (LECHL ratio) was also calculated for each treatment on the basis of the computed tomographic scan obtained immediately after selective B-TACE. The relationships between degree of LE accumulation and the BOASP, as well as the LECHL ratio, were analyzed. Results. Arterial flow beyond the catheter tip was maintained even after balloon inflation. In 39 of 43 treatments, LE inflow into the nontumorous liver parenchyma ceased immediately after LE droplets were filled in arteries of the nontumorous liver parenchyma while LE inflow into the HCC nodule continued (group 1). More dense LE accumulation in HCC nodule was obtained in these 39 treatments. In four treatments, LE inflow both into the nontumorous liver parenchyma and into the HCC nodule continued, and no dense LE accumulation in HCC nodule was observed (group 2). In these four treatments, thick anastomotic vessels with collateral artery were noted. The BOASP in group 1 was (mean {+-} SD) 33.8 {+-} 12.8 mmHg (range 13-64 mmHg) and that in group 2 was 92.3 {+-} 7.4 mmHg (range 83-100 mmHg). There was a statistically significant difference in BOASP between groups (p = 0.00004, Welch's t test). The LECHL ratio in group 1 was 18.3 {+-} 13.9 (range 2.9-54.2) and that in group 2 was 2.6 {+-} 1.1 (range 1.7-4.2). There was a statistically significant difference in the LECHL ratio between the groups (p = 0.000034, Welch's t test). Conclusion. Selective B-TACE induced dense LE accumulation in HCC nodules in 39 (91 %) of 43 treatments in which BOASP was 64 mmHg or less.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of Markov Chain Monte Carlo for Uncertainty Quantification in Quantitative Imaging Problems

The Differential Evolution Adaptive Metropolis (DREAM) method, a Markov chain Monte Carlo approach, is used for optimization and uncertainty analysis of a radioactive source/shield system using pixelated measured data generated by radiation imagers, where each pixel in the image contains a gamma-ray spectrum with statistical uncertainty. DREAM uses this spectral information to determine source thickness and source strength while also propagating uncertainty from the measured data to the solution. Using measurements simulated with GEANT4, successful parameter reconstruction is demonstrated on a numerical test case in a slab/shield geometry. In the presence of statistical noise of 5-9%, parameters are calculated to better than 95% with 2σ error bars that generally encompass the actual values. In a test problem with real-world measurements, source strength per energy line is calculated to within 78-97% of the actual value.

Bledsoe, Keith↗

Bladder–Rectum Spacer Balloon in High-Dose-Rate Brachytherapy in Cervix Carcinoma

Purpose: To compare bladder and rectum doses with the use of a bladder–rectum spacer balloon (BRSB) versus standard gauze packing in the same patient receiving 2 high-dose-rate intracavitary brachytherapy fractions. Methods and Materials: This was a randomized study to compare the reduction in bladder and rectum doses with the use of a BRSB compared with standard gauze packing in patients with carcinoma of the cervix being treated with high-dose-rate intracavitary brachytherapy. The patients were randomized between 2 arms. In arm A, vaginal packing was done with standard gauze packing in the first application, and BRSB was used in the second application. Arm B was the reverse of arm A. The International Commission for Radiation Units and Measurement (ICRU) point doses and doses to 0.1-cm{sup 3}, 1-cm{sup 3}, 2-cm{sup 3}, 5-cm{sup 3}, and 10-cm{sup 3} volumes of bladder and rectum were compared. The patients were also subjectively assessed for the ease of application and the time taken for application. Statistical analysis was done using the paired t test. Results: A total of 43 patients were enrolled; however, 3 patients had to be excluded because the BRSB could not be inserted owing to unfavorable local anatomy. Thus 40 patients (80 plans) were evaluated. The application was difficult in 3 patients with BRSB, and in 2 patients with BRSB the application time was prolonged. There was no significant difference in bladder doses to 0.1 cm{sup 3}, 1 cm{sup 3}, 2 cm{sup 3}, 5 cm{sup 3}, and 10 cm{sup 3} and ICRU bladder point. Statistically significant dose reductions to 0.1-cm{sup 3}, 1-cm{sup 3}, and 2-cm{sup 3} volumes for rectum were observed with the BRSB. No significant differences in 5-cm{sup 3} and 10-cm{sup 3} volumes and ICRU rectum point were observed. Conclusion: A statistically significant dose reduction was observed for small high-dose volumes in rectum with the BRSB. The doses to bladder were comparable for BRSB and gauze packing. Transparent balloons of variable sizes are recommended for patients with a less spacious vaginal cavity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of U.S. Wave Energy Converter (WEC) Test Sites: A Catalogue of Met-Ocean Data.

This report presents met - ocean data and wave energy characteristics at three U.S. wave energy converter (WEC) test and potential deployment sites . Its purpose is to enable the compari son of wave resource characteristics among sites as well as the select io n of test sites that are most suitable for a developer's device and that best meet their testing needs and objectives . It also provides essential inputs for the design of WEC test devices and planning WEC tests, including the planning of deployment and op eration s and maintenance. For each site, this report catalogues wave statistics recommended in the (draft) International Electrotechnical Commission Technical Specification (IEC 62600 - 101 TS) on Wave Energy Characterization, as well as the frequency of oc currence of weather windows and extreme sea states, and statistics on wind and ocean currents. It also provides useful information on test site infrastructure and services .

Dallman, Ann Renee↗