Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “target detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Site Selection for Mars Exopaleontology in 2001

The microbial fossil record encompasses a wide range of information, including cellular remains, stromatolites, biofabrics, trace fossils, biominerals and chemofossils. The preservation of fossils is strongly influenced by the physical, chemical and biological factors of the environment which, acting together, ultimately determine the types of information that will be captured and retained in the rock record. The critical factor in assessing the suitability of a site for a microbial fossil record is the paleoenvironment. The reconstruction of ancient sedimentary environments usually requires the integration of a wide variety of geological information, including the shape, geometry and internal structure of sedimentary deposits, their mineralogy, and geochemistry. For Mars, much of our knowledge about past environments is based on orbital imaging of geomorphic features. This evidence provides an important context and starting point for site selection. However, our knowledge of the martian surface is quite limited, and a major goal of the upcoming exploration effort is to reconstruct the history of Martian volatiles, climate, and hydrology as a context for the exploration for past or present life. Mineralogical mapping from orbit will be an important key in this effort. In exploring for evidence of past life, terrestrial experience suggests that the long-term preservation of biological information as fossils occurs under a fairly narrow range of geological conditions that are well known to paleontologists (1). In detrital sedimentary systems, microbial fossilization is favored by rapid burial in fine-grained, clay-rich sediments. In chemical sedimentary systems, preservation is enhanced by rapid entombment in fine-grained chemical precipitates. For long term preservation, host rocks must be composed of stable minerals that resist chemical weathering, and which form an impermeable matrix and closed chemical system that can protect biosignatures from alteration during subsequent diagenetic change or metamorphism. In this context, host rocks composed of highly ordered, chemically-stable mineral phases, like silica (forming cherts) or phosphate (forming phosphorites), are especially favored. Such lithologies tend to have very long crustal residence times and (along with carbonates and shales), are the most common host rocks for the Precambrian microfossil record on Earth. If we assume that a subsurface hydrosphere has been present throughout martian history, then life could have originated there at any time, perhaps emerging at the surface periodically when climate changes, induced by external forcing or endogenous processes (e.g. volcanism), allowed liquid water to exist at the surface. The recent discovery of subsurface chemolithoautotrophic organisms which are capable of synthesizing organic substrates from C02 and H2 liberated from the aqueous weathering of basalt, is especially. relevant as a model for martian life. While a subsurface habitable zone may yet exist on Mars, access to such environments will likely require drilling to depths of several kilometers. Given the technological challenge of deep drilling, this is unlikely to occur prior to human missions. So, even if there is extant life on Mars today in subsurface habitats, it may be much easier to find its fossil counterparts in ancient deposits exposed at the surface. In exploring for a fossil record in subsurface environments on Mars there are several geological situations that may provide access to the appropriate materials. These include 1) ejecta from impact craters, 2) talus slopes, debris flows or alluvial fans developed below the walls of deep canyons, and 3) the deposits of outflood channels. Examples of aqueous mineral deposits of formed in subsurface environments that could harbor a microbial fossil record include such things as cements in detrital sedimentary rocks, low temperature diagenetic minerals deposited in veins, or filling vesicles in volcanic rocks, and hydrothermal deposits formed below the upper temperature limit for life (about 160 degrees C). There are many sites within the present latitudinal constraints for the 2001 mission (15 deg S to 30 deg N) that meet these requirements. But the practical problem with these kinds of deposits is that they tend to be disseminated, making up only a small percentage of a host rock. Even with mineralogical information provided by the Thermal Emission Spectrometer (TES) presently in orbit around Mars, predicting their occurrence ahead of time may be quite difficult. The deposits of surficial aqueous sedimentary systems are likely to provide the largest targets for site selection in 2001. Of these, the deposits of hydrothermal systems (subaerial and subaqueous thermal springs) have been discussed previously. It is likely that hydrothermal systems were widespread on Mars early in its history and a number of common geo-tectonic settings on Mars are likely to have hosted hydrothermal activity. Most of these are represented within the latitudinal constraints presently identified for 2001. However, the deposits of surface spring systems are likely to be difficult to find as well. On Earth, exposure areas for hydrothermal spring mounds are typically a few square kms, less than a single TES pixel. But such deposits may be quite abundant within some volcanic terrains, It is estimated, for example, that between 15-20% of the floor of Yellowstone caldera is covered by thermal spring deposits. In such abundances, subaerial sinters could well be detected by TES. Where exposed, the shallow subsurface portions of these systems may be quite a lot larger (perhaps tens of square kms), although (as noted above) mineralization may be finely disseminated in the basement rock, making remote detection more difficult. Paleolake Basins. There are a large number of potential paleolake basins on Mars (inclusive of impact craters and volcanic calderas) that have been previously identified using Viking images. Most of these lie in the southern highlands beyond the l5 deg S constraint for 2001. However, deposits of paleolakes may offer the largest and most easily identified exopaleontological targets from orbit. Based on a variety of arguments, some workers have suggested that there was once an ancient ocean on the northern plains, and some sites of interest (potential shoreline terraces) fall within the 30 deg N constraint. From a paleontological standpoint the most interesting places of this type are terminal paleolake basins which are likely to have been both saline and alkaline. Models by Schaefer suggest such environments could be widespread on Mars. The conditions in terminal lake basin settings favor widespread chemical sedimentation, an important condition for microbial fossilization. Important lithological targets for a microbial fossil record in terminal lake basins include spring-deposited carbonates, shoreline cements, a wide variety of evaporite minerals and fine-grained detrital sediments including shales, marls, and water-lain volcanic ash deposits. In developing a strategy to explore for ancient hydrothermal deposits on Mars, we can learn from the methods that have been developed by explorationists to explore for economic mineral deposits on Earth. Due to their simple mineralogy, hydrothermal deposits can often be detected using remote sensing methods. Common thermal spring mineral assemblages include silica, carbonate, and various metallic oxides and sulfides. But there are also a number of diagnostic silicate minerals, including clays, formed by the hydrothermal alteration of country rocks. These hydrothermal minerals have characteristic spectral signatures that could be detected from Mars orbit using high resolution infrared remote sensing methods. In playa lake settings, evaporite deposits often form a predictable "bull's eye" pattern with carbonates being deposited in marginal basin areas, and sulfates and halides occurring progressively more basinward. The floors of some impact craters on Mars, such as "White Rock" and Bequeral Crater (see Oxia Palus NE, Site 148), have floor deposits that could be evaporites, inclusive of carbonates. Evaporite minerals possess characteristic spectral signatures in the infrared and could similarly be identified from Mars orbit using high resolution remote sensing methods. Clearly, utilization of TES data will be important for optimizing site selection for Exopaleontology, and every effort should be made to benefit from that data before a final decision is made.

Farmer, Jack↗

Portable 4.6 Micrometers Laser Absorption Spectrometer for Carbon Monoxide Monitoring and Fire Detection

The air quality aboard manned spacecraft must be continuously monitored to ensure crew safety and identify equipment malfunctions. In particular, accurate real-time monitoring of carbon monoxide (CO) levels helps to prevent chronic exposure and can also provide early detection of combustion-related hazards. For long-duration missions, environmental monitoring grows in importance, but the mass and volume of monitoring instruments must be minimized. Furthermore, environmental analysis beyond low-Earth orbit must be performed in-situ, as sample return becomes impractical. Due to their small size, low power draw, and performance reliability, semiconductor-laser-based absorption spectrometers are viable candidates for this purpose. To reduce instrument form factor and complexity, the emission wavelength of the laser source should coincide with strong fundamental absorption lines of the target gases, which occur in the 3 to 5 micrometers wavelength range for most combustion products of interest, thereby reducing the absorption path length required for low-level concentration measurements. To address the needs of current and future NASA missions, we have developed a prototype absorption spectrometer using a semiconductor quantum cascade laser source operating near 4.6 micrometers that can be used to detect low concentrations of CO with a compact single-pass absorption cell. In this study, we present the design of the prototype instrument and report on measurements of CO emissions from the combustion of a variety of aerospace plastics.

Tunable Environmental Laser Spectrometer (TELS)↗

Discrimination of basic silicate rocks by recognition maps processed from aerial infrared data.

A method is presented which can be used to map silicate rock-type from aerial infrared data. The method has been partially tested over a sand quarry at Mill Creek, Oklahoma, in which highly siliceous targets were discriminated from nonsilicates in the scene. The technique is currently being tested experimentally on basic silicates. On the basis of the Mill Creek results and theoretical considerations, percent SiO2 differences as small as 14% should be detectable with the University of Michigan's currently available detectors.

Vincent, R. K.↗

The prospects for detecting spectral shifts due to satellite sensor aging

Along with responsivity changes due to sensor aging, there may be concurrent spectral changes. A field-measurement approach for detecting postlaunch spectral changes is described. For illustration, one hypothetical model of change (spectral band shift) is explored through simulation for five satellite sensors. Two different types of natural terrain - vegetation and bare soil - are used as test targets.

Suits, G.↗

The gravitational wave experiment

Since the optimum size of a gravitational wave detector is the wave length, interplanetary dimensions are needed for the mHz band of interest. Doppler tracking of Ulysses will provide the most sensitive attempt to date at the detection of gravitational waves in the low frequency band. The driving noise source is the fluctuations in the refractive index of interplanetary plasma. This dictates the timing of the experiment to be near solar opposition and sets the target accuracy for the fractional frequency change at 3.0 x 10 exp -14 for integration times of the order of 1000 sec. The instrumentation utilized by the experiment is distributed between the radio systems on the spacecraft and the seven participating ground stations of the Deep Space Network and Medicina. Preliminary analysis is available of the measurements taken during the Ulysses first opposition test.

Bertotti, B.↗

Tether deployment monitoring system, phase 2

An operational Tether Deployment Monitoring System (TEDEMS) was constructed that would show system functionality in a terrestrial environment. The principle function of the TEDEMS system is the launching and attachment of reflective targets onto the tether during its deployment. These targets would be tracked with a radar antenna that was pointed towards the targets by a positioning system. A spring powered launcher for the targets was designed and fabricated. An instrumentation platform and launcher were also developed. These modules are relatively heavy and will influence tether deployment scenarios, unless they are released with a velocity and trajectory closely matching that of the tether. Owing to the tracking range limitations encountered during field trails of the Radar system, final TEDEMS system integration was not completed. The major module not finished was the system control computer. The lack of this device prevented any subsystem testing or field trials to be conducted. Other items only partially complete were the instrumentation platform launcher and modules and the radar target launcher. The work completed and the tests performed suggest that the proposed system continues to be a feasible approach to tether monitoring, although additional effort is still necessary to increase the range at which modules can be detected. The equipment completed and tested, to the extent stated, is available to NASA for use on any future program that requires tether tracking capability.

Source record↗

Template For Aiming An X-Ray Machine

Relatively inexpensive template helps in aligning x-ray machine with phenolic ring to be inspected for flaws. Phenolic ring in original application part of rocket nozzle. Concept also applicable to x-ray inspection of other rings. Template contains alignment holes for adjusting orientation, plus target spot for adjusting lateral position, of laser spotting beam. (Laser spotting beam coincides with the x-ray beam, turned on later, after alignment completed.) Use of template decreases positioning time and error, providing consistent sensitivity for detection of flaws.

Morphet, W. J.↗

OSSE observations of GX 339-4

The Oriented Scintillation Spectrometer Experiment (OSSE) on the Compton Gamma Ray Observatory (CGRO) observed the Galactic black hole candidate GX 339-4 as a target of oppurtunity in 1991 September, in response to the outburst reported by Burst and Transient Source Experiment (BATSE). We report here on energy spectra in the 50 keV-10 MeV range obtained by OSSE. The source was detected from 50 to 400 keV at a level relative to the Crab Nebula of approximately 30%. The observed spectrum was prescribed reasonably well by a power law with an exponential cutoff; a least-squares fit yielded a photon index of 0.88 +/- 0.05 and a cutoff energy of 68 +/- 2 keV. The addition of a Compton reflection component did not significantly improve the overall fit. An optically thin thermal bremsstrahlung spectrum also provides a good fit, and the thermal Comptonization model of Sunyaev & Titarchuk, while deficient in describing the data above approximately 200 keV, cannot formally be ruled out. A pure power law with reflection does not fit the observed spectrum. During a follow-up observation made in 1991 November the intensity of the source below 100 keV had dropped by more than a factor of 40, and it was no longer detected above approximately 100 keV. The energy spectrum during the November observation could be characterized by a power law with a photon index of 2.3 +/- 0.3; the spectrum was fitted equally well with the same exponentially cutoff power-law model applied to the September observation, reduced in intensity by a factor of approximately 40. During the 1991 September observation, the luminosity in the 50-400 keV band was approximately 2 x 10(exp 37) ergs/s (assuming a distance of 4 kpc), no more than a factor of 5 below the soft X-ray luminosity of GX 339-4 observed in its X-ray high state. The luminosity during the 1991 November observation was approximately 5 x 10(exp 35) ergs/s. Extrapolations of both the exponentially cutoff power-law and Sunyaev-Titarchuk models to the approximately 5-20 keV X-ray band yield flux levels very close to that observed by Ginga during an overlapping interval in 1991 September, when GX 339-4 was reported to be in its low state. This may be one of the strongest indications to date of a direct correspondence between the low X-ray state and gamma-ray outbursts of GX 339-4.

Grabelsky, D. A.↗

All-Optical Micro Motors Based on Moving Gratings in Photosensitive Media

This research effort was a feasibility study of the concept of an all-optical micro motor with a rotor driven by a traveling wave. The wave was a result of a photo induced surface deformation of a photosensitive material produced by a traveling holographic grating. Two phases modulated coherent optical beams were used to generate the grating in two types of photosensitive materials. The materials that were studied were photorefractive crystals and thin polymer films. Theoretical studies were performed on lithium niobate giving predictions of deformations of the order of nanometers. The experimental deformation size was also on the order of nanometers. The deformations were deep enough to provide conditions for the implementation of the all-optical motor using lithium niobate. We also were able to align micron-size dielectric particles along the holographic gratings by means of the periodic electric forces generated by the grating. These forces can also move the particles along the surface if the grating is moving. We then turned our attention on thin films and obtained a deformation visible on the order of 100 microns. An experimental breadboard demonstration of a prototype was done in the summer of 2001 at Glenn Research Center (GRC). The demonstration included the movement of clocks mechanical workings by an optically driven motor based on a polymer film. The application of this technology can be adapted to government as well as industrial uses. One such project is to make a chemical sensor for the detection of hazardous chemicals. The thin polymer film is highly suited for this purpose since a marker dye could be easily placed on the film in order to detect chemical compounds. This system could be a self-regulating chemical monitoring system used on launches of the space shuttle or locations where hazardous chemicals are present. The project provided support for two black minority graduate students targeting MS and PhD degrees in Applied Optics.

Adamovsky, Gregory↗

Diagnostics of Carbon Nanotube Formation in a Laser Produced Plume: An Investigation of the Metal Catalyst by Laser Ablation Atomic Fluorescence Spectroscopy

Carbon nanotubes, elongated molecular tubes with diameters of nanometers and lengths in microns, hold great promise for material science. Hopes for super strong light-weight material to be used in spacecraft design is the driving force behind nanotube work at JSC. The molecular nature of these materials requires the appropriate tools for investigation of their structure, properties, and formation. The mechanism of nanotube formation is of particular interest because it may hold keys to controlling the formation of different types of nanotubes and allow them to be produced in much greater quantities at less cost than is currently available. This summer's work involved the interpretation of data taken last summer and analyzed over the academic year. The work involved diagnostic studies of carbon nanotube formation processes occurring in a laser-produced plume. Laser ablation of metal doped graphite to produce a plasma plume in which carbon nanotubes self assemble is one method of making carbon nanotube. The laser ablation method is amenable to applying the techniques of laser spectroscopy, a powerful tool for probing the energies and dynamics of atomic and molecular species. The experimental work performed last summer involved probing one of the metal catalysts, nickel, by laser induced fluorescence. The nickel atom was studied as a function of oven temperature, probe laser wavelength, time after ablation, and position in the laser produced plume. This data along with previously obtained data on carbon was analyzed over the academic year. Interpretations of the data were developed this summer along with discussions of future work. The temperature of the oven in which the target is ablated greatly influences the amount of material ablated and the propagation of the plume. The ablation conditions and the time scale of atomic and molecular lifetimes suggest that initial ablation of the metal doped carbon target results in atomic and small molecular species. The metal atoms survive for several milliseconds while the gaseous carbon atoms and small molecules nucleate more rapidly. Additional experiments and the development of in situ methods for carbon nanotube detection would allow these results to be interpreted from the perspective of carbon nanotube formation.

deBoer, Gary↗

Optical Observations of GEO Debris with Two Telescopes

For several years, the Michigan Orbital DEbris Survey Telescope (MODEST), the University of Michigan s 0.6/0.9-m Schmidt telescope on Cerro Tololo Inter-American Observatory in Chile has been used to survey the debris population at GEO in the visible regime. Magnitudes, positions, and angular rates are determined for GEO objects as they move across the telescope s field-of-view (FOV) during a 5-minute window. This short window of time is not long enough to determine a full six parameter orbit so usually a circular orbit is assumed. A longer arc of time is necessary to determine eccentricity and to look for changes in the orbit with time. MODEST can follow objects in real-time, but only at the price of stopping survey operations. A second telescope would allow for longer arcs of orbit to obtain the full six orbital parameters, as well as assess the changes over time. An additional benefit of having a second telescope is the capability of obtaining BVRI colors of the faint targets, aiding efforts to determine the material type of faint debris. For 14 nights in March 2007, two telescopes were used simultaneously to observe the GEO debris field. MODEST was used exclusively in survey mode. As objects were detected, they were handed off in near real-time to the Cerro Tololo 0.9-m telescope for follow-up observations. The goal was to determine orbits and colors for all objects fainter than R = 15th magnitude (corresponds to 1 meter in size assuming a 0.2 albedo) detected by MODEST. The hand-off process was completely functional during the final eight nights and follow-ups for objects from night-to-night were possible. The cutoff magnitude level of 15th was selected on the basis of an abrupt change in the observed angular rate distribution in the MODEST surveys. Objects brighter than 15th magnitude tend to lie on a well defined locus in the angular rate plane (and have orbits in the catalog), while fainter objects fill the plane almost uniformly. We need to determine full six-parameter orbits to investigate what causes this change in observed angular rates. Are these faint objects either the same population of high area-to-mass (A/M) objects on eccentric orbits as discovered by the ESA Space Debris Telescope (Schildknecht, et al. 2004), or are they just normal debris from breakups in GEO?

Seitzer, P.↗

The Miniaturized Moessbauer Spectrometers MIMOS II on MER: Four Years of Operation - A Summary

The two Miniaturized Moessbauer Spectrometers (MIMOS II) on board the two Mars Exploration Rovers Spirit and Opportunity have now been collecting important scientific data for more than four years. The spectrometers provide information about Fe-bearing mineral phases and determine Fe oxidation states. The total amount of targets analized exceeds 600, the total integration time exceeds 260 days for both rovers. Since landing, more than five half-lives of the Co-57 MB sources have past (intensity at the time of landing approx. 150 mCi). Current integration times are about 50 hours in order to achieve reasonable statistics as opposed to 8 hours at the beginning of the mission. In total, 13 different mineral phases were detected: Olivine, pyroxene, hematite, magnetite and nanophase ferric oxide were detected at both landing sites. At Gusev, ilmenite, goethite, a ferric sulfate phase and a yet unassigned phase (in the rock Fuzzy Smith) were detected. At Meridiani, jarosite, metallic iron in meteoritic samples (kamacite), troilite, and an unassigned ferric phase were detected. Jarosite and goethite are of special interest, as these minerals are indicators for water activity. In this abstract, an overview of Moessbauer results will be given, with a focus on data obtained since the last martian winter. The MER mission has proven that Moessbauer spectroscopy is a valuable tool for the in situ exploration of extraterrestrial bodies and for the study of Febearing samples. The experience gained through the MER mission makes MIMOS II a obvious choice for future missions to Mars and other targets. Currently, MIMOS II is on the scientific payload of two approved future missions: Phobos Grunt (Russian Space Agency; 2009) and ExoMars (European Space Agency; 2013).

Fleischer, I.↗

Goldstone field test activities: Target search

In March of this year prototype SETI equipment was installed at DSS13, the 26 meter research and development antenna at NASA's Goldstone complex of satellite tracking dishes. The SETI equipment will remain at this site at least through the end of the summer so that the hardware and software developed for signal detection and recognition can be fully tested in a dynamic observatory environment. The field tests are expected to help understand which strategies for observing and which signal recognition algorithms perform best in the presence of strong man-made interfering signals (RFI) and natural astronomical sources.

Tarter, J.↗

Investigation of hard targets for calibration of a coherent Doppler lidar system

The bihemispherical reflectance has been measured for a diffuse gold surface the same as the coating on the integrating sphere, flowers of sulfur, sandblasted aluminum, and 120 grade aluminum oxide sandpaper. The sandpaper measurements indicate that materials with low reflectance cannot be measured until more sensitive detection techniques are found. The sphere had to be used without a detector baffle so an unusual geometry was needed that led to a loss of intensity. Further, it is estimated that some first-strike light entered the detector and the readings could be 1 to 1.5% too low. A limited number of normal incident directional-hemispherical reflectance measurements were made on aluminum and sandpaper. Several recommendations are made: (1) the proper baffle placement; (2) improve lock-in detection using a PAR lock-in amplifier or the heterodyne technique; (3) modification of the sphere so the sample may be mounted at the cell center on a graduate, rotatable table for measurement of directional-hemispherical reflectance; (4) the purchase of additional diffuse gold samples with coatings like the sphere; and (5) better laser temperature control to improve intensity stability.

Anderson, Richard↗

Progress on Passive Sensor for Ultra-Precise Measurement of Carbon Dioxide from Space

Global measurements of atmospheric carbon dioxides (CO2) are needed to resolve significant discrepancies that exist in our understanding of the global carbon budget and, therefore, man's role in global climate change. The science measurement requirements for CO2 are extremely demanding (precision c .3%) No atmospheric chemical species has ever been measured from space with this precision. We are developing a novel application of a Fabry-Perot interferometer to detect spectral absorption of reflected sunlight by CO2 and O2 in the atmosphere. Preliminary design studies indicate that the method will be able to achieve the sensitivity and signal-to-noise required to measure column CO2 at the target specification. We are presently engaged in the construction of a prototype instrument for deployment on an aircraft to test the instrument performance and our ability to retrieve the data in the real atmosphere. In the first 6 months we have assembled a laboratory bench system to begin testing the optical and electronic components. We are also undertaking some measurements of signal and noise levels for actual sunlight reflecting from the ground. We shall present results from some of these ground based studies and discuss their implications for a space based system.

Heaps, William S.↗

The use of multiple indices of physiological activity to access viability in chlorine disinfected Escherichia coli O157:H7

A suite of fluorescent intracellular stains and probes was used, in conjunction with viable plate counts, to assess the effect of chlorine disinfection on membrane potential (rhodamine 123; Rh123 and bis-(1,3-dibutylbarbituric acid) trimethine oxonol; DiBAC4(3)), membrane integrity (LIVE/DEAD BacLight kit), respiratory activity (5-cyano-2,3-ditolyl tetrazolium chloride; CTC) and substrate responsiveness (direct viable counts; DVC) in the commensal pathogen Escherichia coli O157:H7. After a 5 min exposure to the disinfectant, physiological indices were affected in the following order: viable plate counts > substrate responsiveness > membrane potential > respiratory activity > membrane integrity. In situ assessment of physiological activity by examining multiple targets, as demonstrated in this study, permits a more comprehensive determination of the site and extent of injury in bacterial cells following sublethal disinfection with chlorine. This approach to assessing altered bacterial physiology has application in various fields where detection of stressed bacteria is of interest.

NASA Discipline Environmental Health↗

Enhanced Characterization of Microorganisms in the Spacecraft Environment

Spacecraft such as the International Space Station (ISS) and the space shuttles are enclosed environments where crewmembers may spend long periods of time. Currently, crewmembers spend approximately a period of 6 months in the ISS. It is known that these prolonged stays in space may result in weakening of the immune system. Therefore, exposure to opportunistic pathogens or high concentrations of environmental microorganisms may compromise the health of the crew. The detection of biocontaminants in spacecraft environments utilizes culture-based methodology, omitting greater than 90% of all microorganisms including pathogens such as Legionella and Cryptosporidium. Culturable bacteria and fungi have been the only allergens studied; the more potent allergens, such as those from dust mites, have never been tested for in spacecraft environments. In addition, no attempts have been made to monitor microbial toxins in spacecrafts. The present study utilized quantitative polymerase chain reaction (QPCR) as a novel approach for monitoring microorganisms in the spacecraft environment. QPCR is a molecular biology technique that does not rely on the physiological state of the organisms for identification, thereby enabling detection of both culturable and non-culturable organisms. In this project, specific molecular primers and probes were utilized for the detection and quantitation of two fungi of concern in indoor environments, Aspergillus fumigatus and Stachybotrys chartarum. These organisms were selected because of the availability of PCR primers and probes, and to establish the sample processing and analysis methodology that may be employed with additional organisms. Purification methods and QPCR assays were optimized for the detection of these organisms in air, surface, and water; and sample processing and analysis protocols were developed. Preliminary validation of these protocols was conducted in the laboratory with air, surface, and water samples seeded with known concentrations of the target organisms. Additional studies were conducted with bulk materials (HEPA filter pleats and particulate found on the filter screen) obtained from the ISS.

Cruz, Patricia↗

Coronal Dynamics and Complete Flare Energy Budget for the M Dwarf AD Leo

This grant supported the observing and data analysis for FUSE Cycle 3 project C114 to observe the flare star AD Leo for 50 ksec coordinated with HST (Hubble Space Telescope) STIS ultraviolet spectroscopy and Chandra X-ray spectroscopy. Unfortunately, it was impossible to obtain the planned FUSE observations because AD Leo is a low declination target (delta approximately 20 degrees) and was rendered unobservable by restrictions in the sky coverage for FUSE observations. In April 2002 another M dwarf star, EV Lac, which is at significantly higher declination, was substituted for this project. EV Lac was observed by FUSE for a cumulative exposure of 35 ksec on 2002 July 1. The observation used the large LWRS aperture and collected data in time-tagged mode. The LWRS aperture is large enough that the target should remain within the aperture despite the normal level of pointing jitter and target drift experienced during FUSE observing. Our examination of the stellar signal showed that the target was well within the aperture throughout the observation. The data were split into night-time and day-time data so that the effects of airglow emission were recognizable. No obvious flaring, the primary science objective, was detected during the observation. The only stellar lines detected are 0 VI 1031.9, 1037.6 Angstrom, and the C III 1175 Angstrom, UV multiplet and the 977 Angstrom, resonance line. A comparison of the day-time and night-time spectra show that the 0 VI lines and the C III intersystem multiplet are unaffected by airglow features. The day-time data 977 Angstrom profile shows the presence of significant scattered solar C III photons, which should not be present in the night time spectrum. Emission fluxes for these lines were measured by direct summation of the emission lines. No continuum signal was detected in the region of these lines. The cleanest emission line profiles are for the O VI lines and we performed Gaussian fitting for these profiles. Both lines are clearly skewed with the emission peak shifted shortward of the line centroid and with emission extending further in the longward wing than for the shortward wing. A single Gaussian fits the 1032 Angstrom line profile reasonably and gives a line flux similar to that from direct integration with a line width (FWHM) of 0.16 Angstrom, (46 kilometers per second).

Brown, Alexander↗