Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectrometry data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

GlycReSoft: A Software Package for Automated Recognition of Glycans from LC/MS Data

Glycosylation modifies the physicochemical properties and protein binding functions of glycoconjugates. These modifications are biosynthesized in the endoplasmic reticulum and Golgi apparatus by a series of enzymatic transformations that are under complex control. As a result, mature glycans on a given site are heterogeneous mixtures of glycoforms. This gives rise to a spectrum of adhesive properties that strongly influences interactions with binding partners and resultant biological effects. In order to understand the roles glycosylation plays in normal and disease processes, efficient structural analysis tools are necessary. In the field of glycomics, liquid chromatography/mass spectrometry (LC/MS) is used to profile the glycans present in a given sample. This technology enables comparison of glycan compositions and abundances among different biological samples, i.e. normal versus disease, normal versus mutant, etc. Manual analysis of the glycan profiling LC/MS data is extremely time-consuming and efficient software tools are needed to eliminate this bottleneck. In this work, we have developed a tool to computationally model LC/MS data to enable efficient profiling of glycans. Using LC/MS data deconvoluted by Decon2LS/DeconTools, we built a list of unique neutral masses corresponding to candidate glycan compositions summarized over their various charge states, adducts and range of elution times. Our work aims to provide confident identification of true compounds in complex data sets that are not amenable to manual interpretation. This capability is an essential part of glycomics work flows. We demonstrate this tool, GlycReSoft, using an LC/MS dataset on tissue derived heparan sulfate oligosaccharides. The software, code and a test data set are publically archived under an open source license.

Environmental Molecular Sciences Laboratory↗

A TRANSMISSION ELECTRON MICROSCOPY STUDY OF PRESOLAR HIBONITE

We report isotopic and microstructural data on five presolar hibonite grains (KH1, KH2, KH6, KH15, and KH21) identified in an acid residue of the Krymka LL3.1 ordinary chondrite. Isotopic measurements by secondary ion mass spectrometry (SIMS) verified a presolar circumstellar origin for the grains. Transmission electron microscopy (TEM) examination of the crystal structure and chemistry of the grains was enabled by in situ sectioning and lift-out with a focused-ion-beam scanning-electron microscope (FIB-SEM). Comparisons of isotopic compositions with models indicate that four of the five grains formed in low-mass stars that evolved through the red giant/asymptotic giant branches (RGBs/AGBs), whereas one grain formed in the ejecta of a Type II supernova. Selected-area electron-diffraction patterns show that all grains are single crystals of hibonite. Some grains contain minor structural perturbations (stacking faults) and small spreads in orientation that can be attributed to a combination of growth defects and mechanical processing by grain-grain collisions. The similar structure of the supernova grain to those from RGB/AGB stars indicates a similarity in the formation conditions. Radiation damage (e.g., point defects), if present, occurs below our detection limit. Of the five grains we studied, only one has the pure hibonite composition of CaAl{sub 12}O{sub 19}. All others contain minor amounts of Mg, Si, Ti, and Fe. The microstructural data are generally consistent with theoretical predictions, which constrain the circumstellar condensation temperature to a range of 1480-1743 K, assuming a corresponding total gas pressure between 1 x 10{sup -6} and 1 x 10{sup -3} atm. The TEM data were also used to develop a calibration for SIMS determination of Ti contents in oxide grains. Grains with extreme {sup 18}O depletions, indicating deep mixing has occurred in their parent AGB stars, are slightly Ti enriched compared with grains from stars without deep mixing, most likely reflecting differences in grain condensation conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

East River Surface and Pore Water FTICR-MS Data Associated with “Implications of sample treatment on characterization of the riverine environmental metabolome”

Surface and pore water samples were collected from distributed locations around Meander A in East River (Crested Butte, CO, USA) during the summer of 2018. This dataset consists of the characterization of dissolved organic matter using 12 Tesla Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS; in .xml format) analyzed through the Environmental Molecular Sciences Laboratory (EMSL; https://www.pnnl.gov/environmental-molecular-sciences-laboratory) using two different sample pre-treatment methods (solid phase extraction, no solid phase extraction) and two electrospray ionization methods (ESI-positive, ESI-negative) to identify the impacts of these choices on the final dataset. This study aimed to understand how the different sample processing methods influence the resulting FTICR-MS dataset. Any published work that utilizes data presented in this dataset should cite the dataset using the DOI number. If using the dataset, please acknowledge the U.S. Department of Energy (DOE) Office of Science (BER) Subsurface Biogeochemical Research (SBR) program, the Environmental Molecular Sciences Laboratory (EMSL), and Worldwide Hydrobiogeochemical Observation Network for Dynamic River Systems (WHONDRS). The publication DOI will be added to this abstract when available.

54 ENVIRONMENTAL SCIENCES↗

Measurements of radiological data of some amino acids in the energy range 0.122-1.330MeV

Radiological parameters such as μ{sub m}, σ{sub t}, σ{sub e}, Z{sub eff} and N{sub eff} of amino acids, namely Lysine (C{sub 6}H{sub 15}N{sub 2}O{sub 2}), Histidine (C{sub 6}H{sub 9}N{sub 3}O{sub 2}) and Arginine (C{sub 6}H{sub 15}N{sub 4}O{sub 2}), were measured using NaI (Tl)-based gamma spectrometry. Radioactive sources used in the study are {sup 57}Co, {sup 133}Ba, {sup 137}Cs, {sup 54}Mn, {sup 60}Co and {sup 22}Na. Gamma ray transmission method in a narrow beam good geometry set up was used in the study. The measured data were compared against XCOM-based data. The agreement is within 2%.

07 ISOTOPE AND RADIATION SOURCES↗

High Throughput Mode Liquid Microjunction Surface Sampling Probe

A simple and automated spot sampling operation mode for a liquid microjunction surface sampling probe/electrospray ionization mass spectrometry (LMJ-SSP/ESI-MS) system is reported. Prior manual and automated spot sampling methods with this probe relied on a careful, relatively slow alignment of the probe and surface distance (< 20 m spacing) to form the probe - to - surface liquid microjunction critical to successful surface sampling. Moreover, sampling multiple spots required retraction of the surface from the probe and a repeat of this careful probe - to - surface distance alignment at the next sampling position. With the method described here, the probe was not positioned as close to the surface, the exact probe - to - surface positioning was found to be less critical (spanning distances from about 100 300 m), and this distance was not altered during the sampling of an entire array of sample spots. With the probe positioned within the appropriate distance from the surface, the liquid microjunction was formed by letting the liquid from the sampling end of the probe extend out from the probe to the surface. This was accomplished by reducing the self-aspiration liquid flow rate of the probe to a value less than the volume flow rate pumped into the probe. When the self-aspiration rate of the probe was subsequently increased, analytes on the surface that dissolved at the liquid microjunction were aspirated back into the probe with the liquid that created the liquid microjunction and electrosprayed. Presented here are the basics of this new sampling mode, as well as data that illustrate the potential analytical capabilities of the device to conduct high-throughput quantitative analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hormonogenic donor Tyr2522 of bovine thyroglobulin. Insight into preferential T3 formation at thyroglobulin carboxyl terminus at low iodination level

Highlights: • A carboxy-terminal fragment (residues 2515–2750) was isolated from a low-iodine bTg. • Post-translational status of 8 tyrosines in bTg region 2515–2750 was assessed by MS. • Tyr2522 of bovine Tg is an interspecifically conserved hormonogenic donor site. • Propensities of Tyr residues to mono or diiodination optimize T3 yield from Tyr2748. - Abstract: A tryptic fragment (b5{sub TR,NR}), encompassing residues 2515–2750, was isolated from a low-iodine (0.26% by mass) bovine thyroglobulin, by limited proteolysis with trypsin and preparative, continuous-elution SDS–PAGE. The fragment was digested with Asp-N endoproteinase and analyzed by reverse-phase HPLC electrospray ionization quadrupole time-of-flight mass spectrometry, revealing the formation of: 3-monoiodotyrosine and dehydroalanine from Tyr2522; 3-monoiodotyrosine from Tyr2555 and Tyr2569; 3-monoiodotyrosine and 3,5-diiodotyrosine from Tyr2748. The data presented document, by direct mass spectrometric identifications, efficient iodophenoxyl ring transfer from monoiodinated hormonogenic donor Tyr2522 and efficient mono- and diiodination of hormonogenic acceptor Tyr2748, under conditions which permitted only limited iodination of Tyr2555 and Tyr2569, in low-iodine bovine thyroglobulin. The present study thereby provides: (1) a rationale for the preferential synthesis of T3 at the carboxy-terminal end of thyroglobulin, at low iodination level; (2) confirmation for the presence of an interspecifically conserved hormonogenic donor site in the carboxy-terminal domain of thyroglobulin; (3) solution for a previous uncertainty, concerning the precise location of such donor site in bovine thyroglobulin.

60 APPLIED LIFE SCIENCES↗

Detection of the keto-enol tautomerization in acetaldehyde, acetone, cyclohexanone, and methyl vinyl ketone with a novel VUV light source

The discovery of enols in combustion environments and our atmosphere has garnered increasing attention to the many unanswered questions surrounding enol chemistry. The scarcity of experimental data concerning these enols renders combustion and atmospheric models with a lack of constraining parameters, leading to varying computational predictions. Experimental detection is difficult because mass spectrometry, a powerful tool for probing a wide variety of species, cannot distinguish between enols and their thermodynamically favorable ketone isomers. A solution to this ambiguity is to use tunable vacuum ultraviolet (VUV) light from a synchrotron to identify the presence of the enol by its lower ionization energy compared to the isomer. We present a tabletop-scale VUV light source that implements highly cascaded harmonic generation, a new regime of cascaded nonlinear optics, to provide a set of spectral lines spaced by 1.2 eV. We demonstrate that the variety of photon energies available allows us to detect the keto-enol tautomerization of four aldehydes and ketones. By combining this novel VUV light source with an established microreactor, we first revisit the formation of vinyl alcohol from acetaldehyde and confirm that the observed isomerization is indeed unimolecular. Secondly, we observe the thermal tautomerization of acetone to propen-2-ol for the first time. Finally, we observe the thermal tautomerization of cyclohexanone to 1-cyclohexenol and methyl vinyl ketone to 2-hydroxybutadiene, where the results are in good agreement with those reported at a synchrotron. Furthermore, our measurements can be used to constrain models, inform future experimental studies of enol reactivity, and potentially enhance current understanding of combustion and environmental chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

OpenMSI: A High-Performance Web-Based Platform for Mass Spectrometry Imaging

Mass spectrometry imaging (MSI) enables researchers to directly probe endogenous molecules directly within the architecture of the biological matrix. Unfortunately, efficient access, management, and analysis of the data generated by MSI approaches remain major challenges to this rapidly developing field. Despite the availability of numerous dedicated file formats and software packages, it is a widely held viewpoint that the biggest challenge is simply opening, sharing, and analyzing a file without loss of information. Here we present OpenMSI, a software framework and platform that addresses these challenges via an advanced, high-performance, extensible file format and Web API for remote data access (http://openmsi.nersc.gov). The OpenMSI file format supports storage of raw MSI data, metadata, and derived analyses in a single, self-describing format based on HDF5 and is supported by a large range of analysis software (e.g., Matlab and R) and programming languages (e.g., C++, Fortran, and Python). Careful optimization of the storage layout of MSI data sets using chunking, compression, and data replication accelerates common, selective data access operations while minimizing data storage requirements and are critical enablers of rapid data I/O. The OpenMSI file format has shown to provide >2000-fold improvement for image access operations, enabling spectrum and image retrieval in less than 0.3 s across the Internet even for 50 GB MSI data sets. To make remote high-performance compute resources accessible for analysis and to facilitate data sharing and collaboration, we describe an easy-to-use yet powerful Web API, enabling fast and convenient access to MSI data, metadata, and derived analysis results stored remotely to facilitate high-performance data analysis and enable implementation of Web based data sharing, visualization, and analysis.

59 BASIC BIOLOGICAL SCIENCES↗

Chespa: Streamlining Expansive Chemical Space Evaluation of Molecular Sets

Thousands of chemical properties can be calculated for small molecules, which can be used to place the molecules within the context of a broader “chemical space.” These definitions vary based on compounds of interest and the goals for the given chemical space definition. Here, we introduce a customizable (i.e., modular) Python module, chespa, built to easily assess different chemical space definitions through cluster-ing of compounds in these spaces and visualize trends of these clusters. To demonstrate this, chespa currently streamlines prediction of vari-ous molecule descriptors (predicted chemical properties, molecular substructures, AI-based chemical space, and chemical class ontology) in order to test 6 different chemical space definitions. Furthermore, we investigated how these varying definitions trend with mass spectrometry (MS)-based observability, i.e., the ability of a molecule to be observed with MS (e.g., as a function of the molecule ionizability), using an example data set from the U.S. EPA's Non-Targeted Analysis Collaborative Trial (ENTACT), where blinded samples had been analyzed previously, providing 1,398 data points. Improved understanding of observability would offer many advantages in small molecule identifica-tion, such as (i) a priori selection of experimental conditions based on suspected sample composition, (ii) the ability to reduce the number of candidate structures during compound identification by removing those less likely to ionize, and, in turn, (iii) a reduced false discovery rate and increased confidence in identifications. Factors controlling observability are not fully understood, making prediction of this property non-trivial and a prime candidate for chemical space analysis. Chespa is available at github.com/pnnl/chespa.

Nunez, Jamie↗

Products and Kinetics of the Reactions of an Alkane Monolayer and a Terminal Alkene Monolayer with NO₃ Radicals

The reactions of an alkanethiol and a terminal alkenethiol self-assembled monolayer with NO₃ radicals (in the presence of NO₂ and O₂) were studied. For the alkane monolayer, infrared (IR) spectroscopy and time-of-flight secondary ion mass spectrometry (ToF-SIMS) confirmed the formation of organonitrates (RONO₂). The observation of organonitrates is in contrast to the recent X-ray photoelectron spectroscopy (XPS) data, which showed very little nitrogen-containing surface species. The identification of organonitrates may help explain why significant volatilization of the organic chain was not observed in recent studies of alkane monolayer oxidation by NO₃ radicals. The reactive uptake coefficient (g) of NO₃ on alkene monolayers determined in our study is higher than the values obtained in a recent study using liquid and solid alkene bulk films. A possible reason for this difference may be the location of the double bond at the interface. Using the g value determined in our studies, we show that under conditions where NO₃ is high the lifetime of an alkene monolayer in the atmosphere may be short (approximately 20 min). XPS, IR, and ToF-SIMS were used to identify surface functional groups after the oxidation of the alkene monolayers by NO₃. The results are consistent with the formation of C-O, aldehyde/ketone, carboxylic groups, and nitrogen containing species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved molecular level identification of organic compounds using comprehensive two-dimensional chromatography, dual ionization energies and high resolution mass spectrometry

A new analytical methodology combining comprehensive two-dimensional gas chromatography (GC×GC), dual ionization energies and high resolution time of flight mass spectrometry has been developed that improves molecular level identification of organic compounds in complex environmental samples. GC×GC maximizes compound separation providing cleaner mass spectra by minimizing erroneous fragments from interferences and co-eluting peaks. Traditional electron ionization (EI, 70 eV) provides MS fragmentation patterns that can be matched to published EI MS libraries while vacuum ultraviolet photoionization (VUV, 10.5 eV) yields MS with reduced fragmentation enhancing the abundance of the molecular ion providing molecular formulas when combined with high resolution mass spectrometry. We demonstrate this new approach by applying it to a sample of organic aerosol. In this sample, 238 peaks were matched to EI MS library data with FM ≥ 800 but a fifth (42 compounds) were determined to be incorrectly identified because the molecular formula was not confirmed by the VUV MS data. This highlights the importance of using a complementary technique to confirm compound identifications even for peaks with very good matching statistics. In total, 171 compounds were identified by EI MS matching to library spectra with confirmation of the molecular formula from the high resolution VUV MS data and were not dependent on the matching statistics being above a threshold value. A large number of unidentified peaks were still observed with FM < 800, which in routine analysis would typically be neglected. Where possible, these peaks were assigned molecular formulas from the VUV MS data (211 in total). In total, the combination of EI and VUV MS data provides more than twice as much molecular level peak information than traditional approaches and improves confidence in the identification of individual organic compounds. The molecular formula data from the VUV MS data was used, in conjunction with GC×GC retention times and the observed EI MS, to generate a new, searchable EI MS library compatible with the standard NIST MS search program. This library is deliberately dynamic and editable so that other end users can add new entries and update existing entries as new information becomes available.A new analytical methodology has been developed to improve molecular level identification of organic compounds in complex samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Hybrid Approach to Protein Differential Expression in Mass Spectrometry-Based Proteomics

Motivation: Quantitative mass spectrometry-based proteomics involves statistical inference on protein abundance, based on the intensities of each protein's associated spectral peaks. However, typical MS-based proteomics data sets have substantial proportions of missing observations, due at least in part to censoring of low intensities. This complicates intensity-based differential expression analysis. Results: We outline a statistical method for protein differential expression, based on a simple Binomial likelihood. By modeling peak intensities as binary, in terms of 'presence/ absence,' we enable the selection of proteins not typically amendable to quantitative analysis; e.g., 'one-state' proteins that are present in one condition but absent in another. In addition, we present an analysis protocol that combines quantitative and presence/ absence analysis of a given data set in a principled way, resulting in a single list of selected proteins with a single associated FDR.

59 BASIC BIOLOGICAL SCIENCES↗

Gas Surface Interactions Occurring on Materials Within Ultrahigh Vacuum

The physical adsorption of nitrogen on the chemically cleaned surfaces of Pyrex, 347 stainless steel and polycrystalline nickel was investigated over the pressure range 1 x 10 to the minus 12th power to 3 x 10 to the minus 7th power torr and for temperatures 77.4 and 87.4 K. The adsorption data were linearized by the Dubinin-Radushkevich equation. The metal surfaces were cleaned by electron impact desorption (EID) and the desorbed gases analyzed by mass spectrometry. Work function measurements were also used to indicate changes in the surface condition following an EID dose. At least a monolayer of gas was observed to desorb from the metal surfaces. The isotherms revealed that the metal surfaces were very heterogeneous and that the Pyrex surface had been leached. The calculated isosteric heats of adsorption indicated that the relative order of the physical binding of nitrogen to the solids was 347 stainless steel Pyrex nickel. A relationship was observed to exist in the dynamic technique between the equilibration time and the pressure above the absorbed layer. The slope of the log-log plot of these parameters was found to be sensitive to the surface heterogeneity and may be related to the activation energy for surface diffusion of physically absorbed molecules.

Outlaw, R. A.↗

GC-MS in the analysis of organic compounds in meteorites

The application of an analytical approach combining gas chromatography with mass spectrometry (GC-MS) has shown that the amino acid composition of meteorite extracts is quite complex. A computer was used in the evaluation of the data obtained in the investigations. The computer programs developed have been concerned solely with the mass spectra of amino acids. Specialized programs have been written to determine the number of carbon atoms in an amino acid which is a member of any of three subclasses.

Lawless, J. G.↗

Spectral evidence for a carbonaceous chondrite surface composition on Deimos

The surface compositions of Phobos and Deimos as determined by their UV-visible reflectance are compared in order to evaluate the hypothesis that the different surface morphologies of the two satellites are due to different mechanical properties. The UV-visible reflectance spectrum of Deimos is compiled from Mariner 9 UV spectrometry and Canopus star tracker photometry and ground-based colorimetry and polarimetry; the geometric albedo of Deimos is determined from Mariner 9 Canopus star tracker data. The reflectance spectra of Deimos and Phobos are found to be similar in a first approximation, exhibiting low, flat reflectivities in the visible and dropping off sharply in the UV, compatible with a probable carbonaceous chondrite nature for Deimos as well as Phobos and suggesting that their different surface morphologies are most likely due to different orbital histories.

Pang, K. D.↗

Al-26 production profile and model comparisons in Canyon Diablo

The large preatmospheric size of the Canyon Diablo meteorite, a radius of about 15 m, makes it especially suitable for systematic studies of cosmogenic nuclide production rates of iron objects in a 2 pi geometry. To reconstruct the exposure history of the meteoroid, Heymann et al. investigated several fragments recovered from known geographic locations around the crater for their shock features and cosmogenic nobel gases. They applied the Signer-Nier noble gas production rate model to establish the preatmospheric depth of the specimens in the meteoroid. Cosmic ray exposure ages suggested a multi-episodic irradiation, with 170 or 540 Ma being inferred for most of the samples studied while two anomalous specimens indicated a possible third exposure age at 940 Ma. Be-10 and Cl-36 have been measured in a number of these same samples by accelerator mass spectrometry (AMS), with use being made of the preatmospheric depths determined in Heymann et al. to construct production profiles. The present study extends the cosmogenic radionuclide data to Al-26 and compares the results with both the production rate model of Reedy and Arnold and production rates determined from the cross sections used by the Reedy-Arnold model (for the major nuclear reactions making Al-26) in combination with differential fluxes calculated using the Los Alamos High Energy Transport (LAHET) Code System. Model calculations for Be-10 and Cl-36 have also been obtained.

Michlovich, E.↗

Secondary Ion Mass Spectrometry for Mg Tracer Diffusion: Issues and Solutions

A Secondary Ion Mass Spectrometry (SIMS) method has been developed to measure stable Mg isotope tracer diffusion. This SIMS method was then used to calculate Mg self- diffusivities and the data was verified against historical data measured using radio tracers. The SIMS method has been validated as a reliable alternative to the radio-tracer technique for the measurement of Mg self-diffusion coefficients and can be used as a routine method for determining diffusion coefficients.

diffusion↗

Effects of water addition on the combustion of iso -octane investigated in laminar flames, low-temperature reactors, and an HCCI engine

In this work, the effect of H 2 O injection on the combustion process of iso -octane was investigated with the aim to better understand the suitability of water addition as a potential engine control parameter for homogeneous-charge compression ignition (HCCI) combustion. Several experiments were combined including premixed low-pressure flames, a jet-stirred reactor (JSR) and a plug-flow reactor (PFR), both at atmospheric pressure, and a single-cylinder research engine (SCRE) operated with either iso -octane or RON 98 gasoline. The thermal effect of H 2 O addition was determined in laminar premixed iso -octane/O 2 /Ar flames (equivalence ratio $Φ$=1.4, 40 mbar) with H 2 O mole fractions of 0 to 0.22, where water addition reduced the temperature measured by laser-induced fluorescence (LIF) by up to 110 K. Speciation data were obtained from these flames as well as in the JSR ($Φ$=0.65, 933 mbar) and PFR experiments ($Φ$=0.65, 970 mbar) with and without H 2 O addition in the low- to intermediate temperature regime from 700–1100 K. The chemical analysis in these flame and reactor experiments was performed using molecular-beam mass spectrometry (MBMS) employing either electron ionization (EI) in the PFR and premixed flame or single-photon ionization (PI) by tunable vacuum-ultraviolet radiation in the JSR. The effects on species mole fractions were small which is supported by predictions from chemical-kinetic simulations. Quantitative speciation data of the exhaust gas of the SCRE were obtained by using Fourier-transform infrared (FTIR) spectroscopy. A very similar species pool was detected in the laboratory-scale experiments and for the engine operation. It is thus assumed that these results could assist in guiding both the improvement of fundamental chemical-kinetic as well as HCCI engine control models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗