Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “software structure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

EPRI Software for Estimating Decommissioning Waste Volumes - 16046

EPRI has adapted computer software that can estimate the volume and activity content of waste resulting from the dismantlement of nuclear facilities. This software, designated as Automatic Estimation of the Radiological Inventory or AERI, was originally developed by Iberdrola for use by ENRESA in Spain. The software estimates the radiological inventory for all the components and civil structures of the plant or other facility that are included in the physical inventory. The radiological inventory shows the internal and external surface contamination, as well as the volumetric contamination. The processes of the software are able to estimate both the specific activity levels (in Bq/g or pCi/g) for each radionuclide and the surface activity (Bq/cm{sup 2} or dpm/100 cm{sup 2}) for components and civil structures located in the radiological areas. AERI allows the user to extrapolate, through a statistical approach, the contamination levels obtained by sampling data in specific components and civil structures to the entire facility. The main benefits and values obtained with AERI are the following: - The radiological inventory of the plant can be obtained from a limited set of radiological sampling data. Using the mathematical models allows for the optimization of the number of sampling and analysis that needs to be done. The uncertainties of the calculations are reduced with more data. The user must balance the level of uncertainty of the calculations and the number of sample data they will use. - The automatic management of radiological data in short computing times allows for the execution of several scenarios in a reasonable time. Therefore, different radioactive waste and decommissioning hypotheses can be tested. For example, inventory and data can be split into two different set. One of them can be used for obtaining radiological inventory for early dismantling (3 years, as example) and the second one for deferred dismantling (25 years.) - The software supports the planning and implementation of decommissioning strategies for nuclear plants. For instance, several decontamination factors can be evaluated, assuming different level for decontamination of materials, and results for materials from several streams and use of different container types may be included in each evaluation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

COMET-AR User's Manual: COmputational MEchanics Testbed with Adaptive Refinement

The COMET-AR User's Manual provides a reference manual for the Computational Structural Mechanics Testbed with Adaptive Refinement (COMET-AR), a software system developed jointly by Lockheed Palo Alto Research Laboratory and NASA Langley Research Center under contract NAS1-18444. The COMET-AR system is an extended version of an earlier finite element based structural analysis system called COMET, also developed by Lockheed and NASA. The primary extensions are the adaptive mesh refinement capabilities and a new "object-like" database interface that makes COMET-AR easier to extend further. This User's Manual provides a detailed description of the user interface to COMET-AR from the viewpoint of a structural analyst.

Moas, E.↗

Exploring Symmetry as an Avenue to the Computational Design of Large Protein Domains

It has been demonstrated previously that symmetric, homodimeric proteins are energetically favored, which explains their abundance in nature. It has been proposed that such symmetric homodimers underwent gene duplication and fusion to evolve into protein topologies that have a symmetric arrangement of secondary structure elements - 'symmetric superfolds'. Here, the ROSETTA protein design software was used to computationally engineer a perfectly symmetric variant of imidazole glycerol phosphate synthase and its corresponding symmetric homodimer. The new protein, termed FLR, adopts the symmetric ({beta}{alpha}){sub 8} TIM-barrel superfold. The protein is soluble and monomeric and exhibits two-fold symmetry not only in the arrangement of secondary structure elements but also in sequence and at atomic detail, as verified by crystallography. When cut in half, FLR dimerizes readily to form the symmetric homodimer. The successful computational design of FLR demonstrates progress in our understanding of the underlying principles of protein stability and presents an attractive strategy for the in silico construction of larger protein domains from smaller pieces.

59 BASIC BIOLOGICAL SCIENCES↗

Thermodynamic Assessment of the Ternary Alloy System Li-Sn-Zn

The goal of this project is to predict thermodynamics and structure-properties relationships of a series of Li-based alloys for the development of advanced tritium breeding materials that exhibit the beneficial properties of pure lithium while mitigating its chemical reactivity issues for fusion applications. This project makes use of phenomenological thermodynamics based on the CALPHAD (CALculation of PHAse Diagrams), and the use of the Thermo-Calc software (see Appendix A), and experimental calorimetric data and structural characterization for the purpose of validating the data. The initial selection of Sn and Zn as solutes is considered in this first report. Originally Li-Sn alloys have shown promise in meeting tritium breeding ratio (TBR) and energy multiplication requirements. However with the addition of Zn, we expect an improvement in the nuclear, thermal, and chemical requirements of the working fluid. Other substitutes will be considered once neutronic calculations are carried out. Hence the objective of this first task is to carry out a thermodynamic assessment of the Li-Sn-Zn alloy system, as part of the development of a self-consistent and validated thermodynamic database that will include other solute elements for optimizing the properties of blanket materials in fusion-based reactors. This obviously involves the thermodynamic assessment of the three binary subsystems, namely Li-Sn, Li-Zn, and Sn-Zn.

36 MATERIALS SCIENCE↗

SU-E-J-105: Trusting Dose Deformation and Accumulation for GYN Brachytherapy

Purpose: In brachytherapy, structures surrounding the target have the potential to move between treatments and receive unknown dose. Deformable image registration could overcome challenges through dose accumulation. This study uses two possible deformable dose summation techniques and compares the results to point dose summation currently performed in clinic. Methods: Data for ten patients treated with a Syed template was imported into the MIM software (Cleveland, OH). The deformable registration was applied to structures by masking other image data to a single intensity. The registration flow consisted of the following steps: 1) mask CTs so that each of the structures-of-interest had one unique intensity; 2) perform applicator — based rigid registration; 3) Perform deformable registration; 4) Refine registration by changing local alignments manually; 5) Repeat steps 1 to 3 until desired structure adequately deformed; 5) Transfer each deformed contours to the first CT. The deformed structure accuracy was determined by a dice similarity coefficient (DSC) comparison with the first fraction. Two dose summation techniques were investigated: a deformation and recalculation on the structure; and a dose deformation and accumulation method. Point doses were used as a comparison value. Results: The Syed deformations have DSC ranging from 0.53 to 0.97 and 0.75 and 0.95 for the bladder and rectum, respectively. For the bladder, contour deformation addition ranged from −34.8% to 0.98% and dose deformation accumulation ranged from −35% to 29.3% difference from clinical calculations. For the rectum, contour deformation addition ranged from −5.2% to 16.9% and the dose deformation accumulation ranged from −29.1% to 15.3% change. Conclusion: Deforming dose for summation leads to different volumetric doses than when dose is recalculated on deformed structures, raising concerns about the accuracy of the deformed dose. DSC alone cannot be used to establish the accuracy of a deformation for brachy dose summation purpose.

60 APPLIED LIFE SCIENCES↗

TU-C-17A-03: An Integrated Contour Evaluation Software Tool Using Supervised Pattern Recognition for Radiotherapy

Purpose: Radiotherapy (RT) contours delineated either manually or semiautomatically require verification before clinical usage. Manual evaluation is very time consuming. A new integrated software tool using supervised pattern contour recognition was thus developed to facilitate this process. Methods: The contouring tool was developed using an object-oriented programming language C# and application programming interfaces, e.g. visualization toolkit (VTK). The C# language served as the tool design basis. The Accord.Net scientific computing libraries were utilized for the required statistical data processing and pattern recognition, while the VTK was used to build and render 3-D mesh models from critical RT structures in real-time and 360° visualization. Principal component analysis (PCA) was used for system self-updating geometry variations of normal structures based on physician-approved RT contours as a training dataset. The inhouse design of supervised PCA-based contour recognition method was used for automatically evaluating contour normality/abnormality. The function for reporting the contour evaluation results was implemented by using C# and Windows Form Designer. Results: The software input was RT simulation images and RT structures from commercial clinical treatment planning systems. Several abilities were demonstrated: automatic assessment of RT contours, file loading/saving of various modality medical images and RT contours, and generation/visualization of 3-D images and anatomical models. Moreover, it supported the 360° rendering of the RT structures in a multi-slice view, which allows physicians to visually check and edit abnormally contoured structures. Conclusion: This new software integrates the supervised learning framework with image processing and graphical visualization modules for RT contour verification. This tool has great potential for facilitating treatment planning with the assistance of an automatic contour evaluation module in avoiding unnecessary manual verification for physicians/dosimetrists. In addition, its nature as a compact and stand-alone tool allows for future extensibility to include additional functions for physicians’ clinical needs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Supply Chain Risk Management: Data Structuring

Supply chain risk management (SCRM) is an area of research that addresses both logistics concepts to maximize efficiency, reliability, and revenue as well as risk features, such as potential weak points, break points, and vulnerabilities within the supply chain. SCRM is used to find risks introduced at each node in a supply chain and how these risks can impact a company’s products, individuals, customers, and reputation. SCRM is a relatively new field, so standardized processes including data structuring are not fully documented. This paper explains the importance of a standard data structuring methodology and how it can enhance current SCRM efforts. Data ingest, structuring, and analysis are predominantly managed by humans. Automating some of the less complex steps can positively impact SCRM by allowing human analysts to focus on more strategic analyses. Types of data to be collected and structured are collected via publicly available information related to hardware, software, and corporate entities. After the data has been collected, the information is formatted in a specific manner, conforming to a schema, to allow for more effective and efficient ingest for further analysis. This paper outlines data structures used by Pacific Northwest National Laboratory for SCRM research and analysis purposes. These structures have been used for hundreds of analyses and have been successful in developing a common baseline. Data structuring is one of the first steps in data standardization, which will further mature and enhance the SCRM research area.

supply chain risk management, data structuring, re↗

Comparison of Structural Concepts for Transport Aircraft with a Tail Cone Turbine

An evaluation of three structural concepts for an advanced aircraft design with a tail cone turbine is presented. Structural models were developed using an innovative rapid finite element modeling tool called Conceptual Design Shop (CDS). CDS is an attempt to fill a gap in current finite element modeling software to automatically connect wings and tails to the fuselage with sufficient support structure in airframe models. For comparison with actual aircraft structures, a model of a transport aircraft design developed using CDS is compared with published structural weight data for a Boeing 737-200. A method for computing aerodynamic stability parameters from an MSC/NASTRAN finite element analysis output deck is also discussed. Finally, the weight effects for using a tail cone turbine in an advanced transport aircraft design are evaluated by comparing three composite structural models, for which component thicknesses and cross-sections are sized by the Hypersizer software.

Mason, Brian H.↗

Incorporation of a hierarchical grid component structure into GRIDGEN

The underlying framework of the GRIDGEN multiple block grid generation system has been refined so that grid components are now stored within a hierarchical data structure. This restructuring has enhanced the usability of the software by allowing grids to be generated on a more intuitive level. This new framework also provides a means by which the multiple block system can be edited at most any level in the grid generation process. Editing tools are currently being added to GRIDGEN so that a change to the grid can be propagated backward and forward in the data hierarchy. The new data structure, the editing tools, and other recent GRIDGEN improvements are described in this paper.

Steinbrenner, John P.↗

Algorithms and data structures to accelerate network analysis

As the sheer amount of computer generated data continues to grow exponentially, new bottlenecks are unveiled that require rethinking our traditional software and hardware architectures. Here in this paper we present five algorithms and data structures (long queue emulation, lockless bimodal queues, tail early dropping, LFN tables, and multiresolution priority queues) designed to optimize the process of analyzing network traffic. We integrated these optimizations on R-Scope, a high performance network appliance that runs the Bro network analyzer, and present benchmarks showcasing performance speed ups of 5X at traffic rates of 10 Gbps.

97 MATHEMATICS AND COMPUTING↗

Structure determination of an integral membrane protein at room temperature from crystals in situ

The X-ray structure determination of an integral membrane protein using synchrotron diffraction data measured in situ at room temperature is demonstrated. The structure determination of an integral membrane protein using synchrotron X-ray diffraction data collected at room temperature directly in vapour-diffusion crystallization plates (in situ) is demonstrated. Exposing the crystals in situ eliminates manual sample handling and, since it is performed at room temperature, removes the complication of cryoprotection and potential structural anomalies induced by sample cryocooling. Essential to the method is the ability to limit radiation damage by recording a small amount of data per sample from many samples and subsequently assembling the resulting data sets using specialized software. The validity of this procedure is established by the structure determination of Haemophilus influenza TehA at 2.3 Å resolution. The method presented offers an effective protocol for the fast and efficient determination of membrane-protein structures at room temperature using third-generation synchrotron beamlines.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

LigninGraphs: lignin structure determination with multiscale graph modeling

Lignin is an aromatic biopolymer found in ubiquitous sources of woody biomass. Designing and optimizing lignin valorization processes requires a fundamental understanding of lignin structures. Experimental characterization techniques, such as 2D-heteronuclear single quantum coherence (HSQC) nuclear magnetic resonance (NMR) spectra, could elucidate the global properties of the polymer molecules. Computer models could extend the resolution of experiments by representing structures at the molecular and atomistic scales. We introduce a graph-based multiscale modeling framework for lignin structure generation and visualization. The framework employs accelerated rejection-free polymerization and hierarchical Metropolis Monte Carlo optimization algorithms. We obtain structure libraries for various lignin feedstocks based on literature and new experimental NMR data for poplar wood, pinewood, and herbaceous lignin. The framework could guide researchers towards feasible lignin structures, efficient space exploration, and future kinetics modeling. Its software implementation in Python, LigninGraphs, is open-source and available on GitHub.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Combined protein construct and synthetic gene engineering for heterologous protein expression and crystallization using Gene Composer

With the goal of improving yield and success rates of heterologous protein production for structural studies we have developed the database and algorithm software package Gene Composer. This freely available electronic tool facilitates the information-rich design of protein constructs and their engineered synthetic gene sequences, as detailed in the accompanying manuscript. In this report, we compare heterologous protein expression levels from native sequences to that of codon engineered synthetic gene constructs designed by Gene Composer. A test set of proteins including a human kinase (P38{alpha}), viral polymerase (HCV NS5B), and bacterial structural protein (FtsZ) were expressed in both E. coli and a cell-free wheat germ translation system. We also compare the protein expression levels in E. coli for a set of 11 different proteins with greatly varied G:C content and codon bias. The results consistently demonstrate that protein yields from codon engineered Gene Composer designs are as good as or better than those achieved from the synonymous native genes. Moreover, structure guided N- and C-terminal deletion constructs designed with the aid of Gene Composer can lead to greater success in gene to structure work as exemplified by the X-ray crystallographic structure determination of FtsZ from Bacillus subtilis. These results validate the Gene Composer algorithms, and suggest that using a combination of synthetic gene and protein construct engineering tools can improve the economics of gene to structure research.

59 BASIC BIOLOGICAL SCIENCES↗

Computation of Effective Radiative Properties of Powders for Selective Laser Sintering Simulations

Selective laser sintering (SLS) is an additive manufacturing technique for rapidly creating parts directly from a computer-aided design (CAD) model by using a laser to fuse successive layers of powder. However, better understanding of the effect of particle-level variations on the overall build quality is needed. In this work, we investigated these effects computationally by considering the role of the particle size distribution and variations in the powder bed depth to mimic the part complexity found in overhangs and protrusions. In addition, the results from these studies can be distilled to obtain better effective material properties such as laser absorptivity and laser extinction coefficient that are needed for continuum models of the process. We implement a Monte Carlo ray-tracing algorithm within the discrete element model in the open-source simulation software MFiX. Random, loose-packed, particle bed structures are generated, and effective absorptivity and extinction coefficients are calculated. Results are compared against previous computational and experimental measurements for free, monodisperse, and deep powder beds, with good agreement being obtained. Correlations along with uncertainties are developed to allow the effective absorptivity and extinction coefficient as a function of various particle and operational parameters to be accurately set in SLS macroscale models.

Moser, Daniel↗

Practical Method of Adaptive Radiotherapy for Prostate Cancer Using Real-Time Electromagnetic Tracking

Purpose: We have created an automated process using real-time tracking data to evaluate the adequacy of planning target volume (PTV) margins in prostate cancer, allowing a process of adaptive radiotherapy with minimal physician workload. We present an analysis of PTV adequacy and a proposed adaptive process. Methods and Materials: Tracking data were analyzed for 15 patients who underwent step-and-shoot multi-leaf collimation (SMLC) intensity-modulated radiation therapy (IMRT) with uniform 5-mm PTV margins for prostate cancer using the Calypso Registered-Sign Localization System. Additional plans were generated with 0- and 3-mm margins. A custom software application using the planned dose distribution and structure location from computed tomography (CT) simulation was developed to evaluate the dosimetric impact to the target due to motion. The dose delivered to the prostate was calculated for the initial three, five, and 10 fractions, and for the entire treatment. Treatment was accepted as adequate if the minimum delivered prostate dose (D{sub min}) was at least 98% of the planned D{sub min}. Results: For 0-, 3-, and 5-mm PTV margins, adequate treatment was obtained in 3 of 15, 12 of 15, and 15 of 15 patients, and the delivered D{sub min} ranged from 78% to 99%, 96% to 100%, and 99% to 100% of the planned D{sub min}. Changes in D{sub min} did not correlate with magnitude of prostate motion. Treatment adequacy during the first 10 fractions predicted sufficient dose delivery for the entire treatment for all patients and margins. Conclusions: Our adaptive process successfully used real-time tracking data to predict the need for PTV modifications, without the added burden of physician contouring and image analysis. Our methods are applicable to other uses of real-time tracking, including hypofractionated treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

From NWChem to NWChemEx: Evolving with the Computational Chemistry Landscape

Since the advent of the first computers, chemists have been at the forefront of using computers to understand and solve complex chemical problems. As the hardware and software have evolved, so have the theoretical and computational chemistry methods and algorithms. Parallel computers clearly changed the common computing paradigm in the late 1970s and 80s, and the field has again seen a paradigm shift with the advent of graphical processing units. This review explores the challenges and some of the solutions in transforming software from the terascale to the petascale and now to the upcoming exascale computers. While discussing the field in general, NWChem and its redesign, NWChemEx, will be highlighted as one of the early codesign projects to take advantage of massively parallel computers and emerging software standards to enable large scientific challenges to be tackled.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SciPy 1.0: fundamental algorithms for scientific computing in Python

SciPy is an open-source scientific computing library for the Python programming language. Since its initial release in 2001, SciPy has become a de facto standard for leveraging scientific algorithms in Python, with over 600 unique code contributors, thousands of dependent packages, over 100,000 dependent repositories and millions of downloads per year. In this work, we provide an overview of the capabilities and development practices of SciPy 1.0 and highlight some recent technical developments.

97 MATHEMATICS AND COMPUTING↗