Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scan report”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Spatially resolved absolute spectrophotometry of Saturn - 3390 to 8080 A

A series of spatially resolved absolute spectrophotometric measurements of Saturn was conducted for the expressed purpose of calibrating the data obtained with the Imaging Photopolarimeter (IPP) on Pioneer 11 during its recent encounter with Saturn. All observations reported were made at the Mt. Wilson 1.5-m telescope, using a 1-m Ebert-Fastie scanning spectrometer. Spatial resolution was 1.92 arcsec. Photometric errors are considered, taking into account the fixed error, the variable error, and the composite error. The results are compared with earlier observations, as well as with synthetic spectra derived from preliminary physical models, giving attention to the equatorial region and the South Temperate Zone.

Bergstralh, J. T.↗

Measurement of solar radius changes

Results of daily photometric measurements of the solar radius from Mt. Wilson over the past seven years are reported. Reduction of the full disk magnetograms yields a formal error of 0.1 arcsec in the boustrophedonic scans in the 5250.2 A FeI line. 150 scan lines comprise each observation; 1,412 observations were made from 1974-1981. Measurement procedures, determination of the scattered light of the optics and the atmosphere, and error calculations are described, noting that days of poor atmospheric visibility are omitted from the data. The horizontal diameter of the sun remains visually fixed while the vertical component changes due to atmospheric diffraction; error accounting for thermal effects, telescope aberrations, and instrument calibration are discussed, and results, within instrument accuracy, indicate no change in the solar radius over the last seven years.

Labonte, B. J.↗

Time effect of erosion by solid particle impingement on ductile materials

Erosion and morphological studies of several metals and alloys eroded by normal impingement jets of spherical glass beads and angular crushed-glass erodent particles were conducted. Erosion morphology (the width, depth, and width-depth ratio of the pit) was studied in order to fully investigate the effect of time on erosion rate. The eroded surfaces were studied with a scanning electron microscope, and surface profiles were measured with a profilometer. A large amount of experimental data reported in the literature was also analyzed in order to understand the effect of variables such as the type of device, the erodent particle size and shape, the impact velocity, and the abrasive charge on erosion-rate-versus-time curves. In the present experiments the pit-width-versus-time or pit-depth-versus-time curves were similar to erosion-versus-time curves for glass-bead impingement. The pit-depth-rate-versus-time curves were similar to erosion-rate-versus-time curves for crushed-glass impingement. Analysis of experimental data with two forms of glass resulted in four types of erosion-rate-versus-time curves: (1) incubation, acceleration, and steady-state periods (type I), (2) incubation, acceleration, deceleration, and steady-state periods (type III), (3) incubation, acceleration, peak rate, and deceleration periods (type IV), and (4) incubation, acceleration, steady-state, and deceleration periods (type V).

Rao, P. V.↗

TM Geometric Performance: Line to Line Displacement Analysis (LLDA)

An early acquired TM data frame (track 23, frame 35 of 22 August 1982) was used to assess the geometric performance of the LANDSAT-4 thematic mapper instrument. The developed method consists in determining the displacements of adjacent lines by locating the maximum of the correlation profile between the two lines. Then the line to line displacement is used to characterize the TM instrument in respect to: scan to scan jitter and image skew, scan profile non-linearity, along scan jitter, detector to detector displacement, and band to band displacement. To verify the quality of the reported performance parameters, some extracted geometric parameters were used to correct the original raw data. Comparison between P-tape data and results of reprocessed data shows no significant differences in an area of 1024 x 1024 pixels.

Fusco, L.↗

Polarization Rotation and the Third Stokes Parameter: The Effects of Spacecraft Attitude and Faraday Rotation

The third Stokes parameter of ocean surface brightness temperatures measured by the WindSat instrument is sensitive to the rotation angle between the polarization vectors at the ocean surface and the instrument. This rotation angle depends on the spacecraft attitude (roll, pitch, yaw) as well as the Faraday rotation of the electromagnetic radiation passing through the Earth's ionosphere. Analyzing the WindSat antenna temperatures, we find biases in the third Stokes parameter as function of the along-scan position of up to 1.5 K in all feedhorns. This points to a misspecification of the reported spacecraft attitude. A single attitude correction of -0.16deg roll and 0.18deg pitch for the whole instrument eliminates all the biases. We also study the effect of Faraday rotation at 10.7 GHz on the accuracy of the third Stokes parameter and the sea surface wind direction retrieval and demonstrate how this error can be corrected using values from the International Reference Ionosphere for the total electron content when computing Faraday rotation.

Meissner, Thomas↗

Sampling and Analysis of Impact Crater Residues found on the Wide Field Planetary Camera-2 Radiator

After nearly 16 years on orbit, the Wide Field Planetary Camera-2 (WFPC-2) was recovered from the Hubble Space Telescope in May 2009 during the 12 day shuttle mission designated STS-125. During that exposure to the low Earth orbit environment, the WFPC-2 radiator was struck by approximately 700 impactors producing crater features 300 micrometers and larger in size. Following an optical inspection of these features in 2009, an agreement was reached for the joint NASA-ESA examination and characterization of crater residues, the remnants of the projectile, in 2011. Active examination began in 2012, with 486 of the impact features being cored at NASA Johnson Space Center fs (JSC) Space Exposed Hardware cleanroom and curation facility. The core samples were subsequently divided between NASA and ESA. NASA's analysis was conducted at JSC fs Astromaterials Research and Exploration Science (ARES) Division, using scanning electron microscopy (SEM)/ energy dispersive X-ray spectrometry (EDS) methods, and ESA's analysis was conducted at the Natural History Museum (NHM) again using SEM/EDS, and at the University of Surrey Ion Beam Centre (IBC) using ion beam analysis (IBA) with a scanned proton microbeam. As detailed discussion of the joint findings remains premature at this point, this paper reports on the coring technique developed; the practical taxonomy developed to classify residues as belonging either to anthropogenic "orbital debris" or micrometeoroids; and the protocols for examination of crater residues. Challenges addressed in coring were the relative thickness of the surface to be cut, protection of the impact feature from contamination while coring, and the need to preserve the cleanroom environment so as to preclude or minimize cross-contamination. Classification criteria are summarized, including the assessment of surface contamination and surface cleaning. Finally, we discuss the analytical techniques used to examine the crater residues. We employed EDS from either electron excitation (SEM-EDS) and, in a minority of cases for cores assessed as "difficult" targets, proton excitation (IBA). All samples were documented by electron imagery: backscattered electron imagery in the SEM, and where appropriate, secondary electron imagery during IBA.

Kearsley, A. T.↗

Nanoscale Measurements of the Surface Photovoltage in Cu(In,Ga)Se2, Cu2ZnSn4, and Cu2ZnSnSe4 Thin Films: The Role of the Surface Electronics on the Efficiency of Solar Cells: Preprint

We report on recent advances in the development of nanoscale measurements of the surface photovoltage (SPV) based on scanning tunneling microscopy (STM) and its application to the kesterites Cu2ZnSnS4 (CZTS) and Cu2ZnSnSe4 (CZTSe). One critical aspect of the electronic structure of Cu(In,Ga)Se2 (CIGS) that has yet to be determined in their related kesterite compounds is the character of the surface electronics. In CIGS, spontaneous deviations in the stoichiometry of the surface cause a depletion (or even a type inversion) region that reinforces the CIGS homojunction. First-principle calculations predict that this inversion region will be more difficult to form in CZTS. In this contribution, the characteristics of the surface space charge region for both CIGS and CZTS(e) are investigated by STM. The implications of the results of these measurements on the future development of CZTS solar cells will be discussed.

14 SOLAR ENERGY↗

The feasibility of a regional CTDI{sub vol} to estimate organ dose from tube current modulated CT exams

Purpose: In AAPM Task Group 204, the size-specific dose estimate (SSDE) was developed by providing size adjustment factors which are applied to the Computed Tomography (CT) standardized dose metric, CTDI{sub vol}. However, that work focused on fixed tube current scans and did not specifically address tube current modulation (TCM) scans, which are currently the majority of clinical scans performed. The purpose of this study was to extend the SSDE concept to account for TCM by investigating the feasibility of using anatomic and organ specific regions of scanner output to improve accuracy of dose estimates. Methods: Thirty-nine adult abdomen/pelvis and 32 chest scans from clinically indicated CT exams acquired on a multidetector CT using TCM were obtained with Institutional Review Board approval for generating voxelized models. Along with image data, raw projection data were obtained to extract TCM functions for use in Monte Carlo simulations. Patient size was calculated using the effective diameter described in TG 204. In addition, the scanner-reported CTDI{sub vol} (CTDI{sub vol,global}) was obtained for each patient, which is based on the average tube current across the entire scan. For the abdomen/pelvis scans, liver, spleen, and kidneys were manually segmented from the patient datasets; for the chest scans, lungs and for female models only, glandular breast tissue were segmented. For each patient organ doses were estimated using Monte Carlo Methods. To investigate the utility of regional measures of scanner output, regional and organ anatomic boundaries were identified from image data and used to calculate regional and organ-specific average tube current values. From these regional and organ-specific averages, CTDI{sub vol} values, referred to as regional and organ-specific CTDI{sub vol}, were calculated for each patient. Using an approach similar to TG 204, all CTDI{sub vol} values were used to normalize simulated organ doses; and the ability of each normalized dose to correlate with patient size was investigated. Results: For all five organs, the correlations with patient size increased when organ doses were normalized by regional and organ-specific CTDI{sub vol} values. For example, when estimating dose to the liver, CTDI{sub vol,global} yielded a R{sup 2} value of 0.26, which improved to 0.77 and 0.86, when using the regional and organ-specific CTDI{sub vol} for abdomen and liver, respectively. For breast dose, the global CTDI{sub vol} yielded a R{sup 2} value of 0.08, which improved to 0.58 and 0.83, when using the regional and organ-specific CTDI{sub vol} for chest and breasts, respectively. The R{sup 2} values also increased once the thoracic models were separated for the analysis into females and males, indicating differences between genders in this region not explained by a simple measure of effective diameter. Conclusions: This work demonstrated the utility of regional and organ-specific CTDI{sub vol} as normalization factors when using TCM. It was demonstrated that CTDI{sub vol,global} is not an effective normalization factor in TCM exams where attenuation (and therefore tube current) varies considerably throughout the scan, such as abdomen/pelvis and even thorax. These exams can be more accurately assessed for dose using regional CTDI{sub vol} descriptors that account for local variations in scanner output present when TCM is employed.

60 APPLIED LIFE SCIENCES↗

SU-D-202-01: Functional Lung Avoidance and Response-Adaptive Escalation (FLARE) RT: Feasibility of a Precision Radiation Oncology Strategy

Purpose: NSCLC patient RT is planned without consideration of spatial heterogeneity in lung function or tumor response, which may have contributed to failed uniform dose escalation in a randomized trial. The feasibility of functional lung avoidance and response-adaptive escalation (FLARE) RT to reduce dose to [{sup 99m}Tc]MAA-SPECT/CT perfused lung while redistributing 74Gy within [{sup 18}F]FDG-PET/CT biological target volumes was assessed. Methods: Eight Stage IIB–IIIB NSCLC patients underwent FDG-PET/CT and MAA-SPECT/CT treatment planning scans. Perfused lung objectives were derived from scatter/collimator/attenuation-corrected MAA-SPECT uptake relative to ITV-subtracted lung to maintain <20Gy mean lung dose (MLD). Prescriptions included 60Gy to PTV and concomitant boost of 74Gy mean to biological target volumes (BTV=GTV+PET margin) scaled to each BTV voxel by relative FDG-PET SUV. Dose-painting-by-numbers prescriptions were integrated into commercial TPS via previously reported ROI discretization. Dose constraints for lung, heart, cord, and esophagus were defined. FLARE RT plans were optimized with VMAT, proton pencil beam scanning (PBS) with 3%-3mm robust optimization, and combination PBS (avoidance) plus VMAT (escalation). Dosimetric differences were evaluated by Friedman non-parametric paired test with multiple sampling correction. Results: PTV and normal tissue objectives were not violated in 24 FLARE RT plans. Population median of mean BTV dose was 73.7Gy (68.5–75.5Gy), mean FDG-PET peak dose was 89.7Gy (73.5–103Gy), MLD was 12.3Gy (7.5–19.6Gy), and perfused MLD was 4.8Gy (0.9–12.1Gy). VMAT achieved higher dose to the FDG-PET peak subvolume (p=0.01), while PBS delivered lower dose to lung (p<0.001). Voxelwise linear correlation between BTV dose and FDG-PET uptake was higher for VMAT (R=0.93) and PBS+VMAT (R=0.94) compared to PBS alone (R=0.89). Conclusion: FLARE RT is feasible with VMAT and PBS. A combination of PBS for functional lung avoidance and VMAT for FDG-PET dose escalation balances target/normal tissue objective tradeoffs. These results support future testing of FLARE RT safety and efficacy within a precision radiation oncology trial. This work was supported by a Research Scholar grant from the Radiological Society of North American Research & Education Foundation.

60 APPLIED LIFE SCIENCES↗

Revisiting heat treatment and surface activation of GaAs photocathodes: In situ studies using scanning tunneling microscopy and photoelectron spectroscopy

The lifetime of GaAs photocathodes in polarized electron guns is limited due to the delicate activation layer. An atomically clean and smooth GaAs surface is needed to deposit a robust activation layer, such as Cs 2 Te, with longer lifetime compared to traditional (Cs,O) activation. A previous experiment with Cs 2 Te activation on GaAs used heat cleaning temperatures around 400°C to avoid an increase in surface roughness [Bae et al., Appl. Phys. Lett. 112, 154101 (2018)]. Furthermore, high-temperature heat cleaning around 580°C, which results in a relatively contamination-free surface, could be one possible way to improve quantum efficiency. However, one should be cautious about surface roughness degradation during high-temperature heat cleaning. In this paper, we report results of surface roughness measurements on native, heat cleaned, and (Cs,O) activated GaAs photocathodes under vacuum. The results, measured by ultrahigh vacuum scanning tunneling microscopy, show that the surface roughness improves as the heat cleaning temperature is increased, by at least a factor of three for 580°C heat cleaning, compared to the native sample. Activation with (Cs,O) is shown to increase surface roughness by a factor of four compared to a 580°C heat cleaned sample. This confirms that high-temperature heat cleaning can be useful for depositing good quality robust activation layers on GaAs. Additionally, we also report chemical analysis for each step of preparation for p-doped GaAs photocathodes using X-ray photoelectron spectroscopy (XPS), angle-resolved XPS, and ultraviolet photoelectron spectroscopy. Our results indicate that the (Cs,O) activation layer forms a sandwich structure consists of Cs and oxygen. We found no formation of any specific compound such as Cs 2 O or Cs 11 O 3 .

43 PARTICLE ACCELERATORS↗

Experimental Demonstration of Wakefield Acceleration in a Tunable Dielectric Loaded Accelerating Structure

We report on a collinear wakefield experiment using the first tunable dielectric loaded accelerating structure. By introducing an extra layer of nonlinear ferroelectric, which has a dielectric constant sensitive to temperature and dc bias, the frequency of a dielectric loaded accelerating structure can be tuned. During the experiment, the energy of a witness bunch at a fixed delay with respect to the drive beam was measured while the temperature of the structure was scanned over a 50 deg. C range. The energy change corresponded to a change of more than half of the nominal structure wavelength.

43 PARTICLE ACCELERATORS↗

Three-dimensional shock structure of the Orion KL outflow with IGRINS

We report a study of the three-dimensional (3D) outflow structure of a 15″ × 13″ area around the H{sub 2} peak 1 in Orion KL with slit-scan observations (13 slits) using the Immersion Grating Infrared Spectrograph. The datacubes have a high-velocity resolution (∼7.5 km s{sup −1}), provide high-contrast imaging within ultra-narrow bands, and enable the detection of the main stream of the previously reported H{sub 2} outflow fingers. We identified 31 distinct fingers in the H{sub 2} 1−0 S(1) λ2.122 μm emission. The line profile at each finger shows multiple-velocity peaks with a strong low-velocity component around the systemic velocity at V{sub LSR} = +8 km s{sup −1} and high-velocity emission (|V{sub LSR}| = 45–135 km s{sup −1}), indicating a typical bow-shock. The observed radial velocity gradients of ∼4 km s{sup −1} arcsec{sup −1} agree well with the velocities inferred from large-scale proper motions, where the projected motion is proportional to the distance from a common origin. We construct a conceptual 3D map of the fingers with estimated inclination angles of 57°–74°. The extinction difference (ΔA {sub v} > 10 mag) between blueshifted and redshifted fingers indicates high internal extinction. The extinction, the overall angular spread, and the scale of the flow argue for an ambient medium with a very high density (10{sup 5}–10{sup 6} cm{sup −3}), consistent with molecular line observations of the Orion Molecular Cloud core. The radial velocity gradients and the 3D distributions of the fingers together support the hypothesis of a simultaneous radial explosion of the Orion KL outflow.

79 ASTRONOMY AND ASTROPHYSICS↗

SS Cygni as a hard X-ray source identified with the scanning modulation collimator on HEAO 1

Hard X-ray emission from a 15 min by 1.5 deg area containing SS Cygni had previously been reported and identified with SS Cygni. This paper reports a 0.4 sq arc min measurement of the position of the X-ray source with the HEAO 1 modulation collimator experiment which leads to an unequivocal identification of SS Cygni as an X-ray emitter in the 2-10 keV energy range. The historical light curve in hard X-rays was also investigated by analyzing relevant Uhuru data, and two instances of possible source detection in the 2-6 keV band were noted. From Ariel 5 observations it is calculated that the X-ray luminosity of SS Cygni in the 2-10 keV energy range is of the order of 10 to the 33rd erg/sec in the optical low state and probably at least an order of magnitude less in the high state. By contrast, the soft X-ray luminosity increases by an order of magnitude between the optical low and high states. A coronal model or accretion onto the white dwarf can account for the inverse correlation of the soft and hard X-rays.

Fabbiano, G.↗

Effect of Water Vapor, Temperature, and Rapid Annealing on Formamidinium Lead Triiodide Perovskite Crystallization

Perovskite-based solar cells are one of the emerging candidates for radically lower cost photovoltaics. Herein, we report on the synthesis and crystallization of organic-inorganic formamidinium lead triiodide perovskite films under controlled atmospheric and environmental conditions. Using in situ (scanning) transmission electron microscopy, we make observations of the crystallization process of these materials in nitrogen and oxygen gas with and without the presence of water vapor. Complementary planar samples were also fabricated in the presence of water vapor and characterized by in situ X-ray diffraction. Direct observations of the material structure and final morphology indicate that the exposure to water vapor results in a porous film that is metastable, regardless of the presence of argon, nitrogen, or oxygen. However, the optimal crystallization temperature of 175 °C is unperturbed across conditions. Rapid modulation about the annealing temperature of 175 °C in ±25 °C steps (150-200 °C) promotes crystallization and significantly improves the film morphology by overcoming the presence of impregnated water trapped in the material. Following this processing protocol, we demonstrate substantial growth to micron-size grains via observation inside of an environmentally controlled transmission electron microscope. Adapting this insight from our in situ microscopy, we are able to provide an informed materials protocol to control the structure and morphology of these organic-inorganic semiconductors, which is readily applicable to benchtop device growth strategies.

36 MATERIALS SCIENCE↗

SU-F-J-123: CT-Based Determination of DIBH Variability and Its Dosimetric Impact On Post-Mastectomy Plus Regional Nodal Radiation Therapy

Purpose: Breast cancer radiotherapy delivered using voluntary deep inspiration breath-hold (DIBH) requires reproducible breath holds, particularly when matching supraclavicular fields to tangential fields. We studied the impact of variation in DIBHs on CTV and OAR dose metrics by comparing the dose distribution computed on two DIBH CT scans taken at the time of simulation. Methods: Ten patients receiving 50Gy in 25 fractions to the left chestwall and regional lymph nodes were studied. Two simulation CT scans were taken during separate DIBHs along with a free-breathing (FB) scan. The treatment was planned using one DIBH CT. The dose was recomputed on the other two scans using adaptive planning (Pinnacle 9.10) in which the scans are registered using a cross-correlation algorithm. The chestwall, lymph nodes and OARs were contoured on the scans following the RTOG consensus guidelines. The overall translational and rotational variation between the DIBH scans was used to estimate positional variation between breath-holds. Dose metrics between plans were compared using paired t-tests (p < 0.05) and means and standard deviations were reported. Results: The registration parameters were sub-millimeter and sub-degree. Although DIBH significantly reduced mean heart dose by 2.4Gy compared to FB (p < 0.01), no significant changes in dose were observed for targets or OARs between the two DIBH scans. Nodal coverage as assessed by V90% was 90%±8% and 89%±8% for supraclavicular and 99%±2% and 97%±22% for IM nodes. Though a significant decrease (10.5%±12.4%) in lung volume in the second DIBH CT was observed, the lung V20Gy was unchanged (14±2% and 14±3%) between the two DIBH scans. Conclusion: While the lung volume often varied between DIBHs, the CTV and OAR dose metrics were largely unchanged. This indicates that manual DIBH has the potential to provide consistent dose delivery to the chestwall and regional nodes targets when using matched fields.

60 APPLIED LIFE SCIENCES↗

Probing and Understanding the Spatial and Energy Distributions of Plasmonic Hot Carriers via Single-Molecule Quantum Transport

The generation of hot carriers in plasmonic nanostructures offers new transformative opportunities for a range of applications, including solar energy harvesting, photochemistry, and photodetection. To better understand such phenomena, this project aims to develop an experimental approach to study and understand hot carrier distributions in photoexcited plasmonic nanostructures. The developed experimental approach, combining scanning probe-based single-molecule quantum transport measurements with plasmonic excitation methods, leverages nanoscopic single molecules as quantum energy filters to selectively access hot carriers in a variety of plasmonic nanostructures. This report summarizes the key outcomes, impacts, and lessons learned in the first two years of the project. Over the past two years, important progress was made in achieving the project's goals, including the development of the scanning probe-based experimental platform, fabrication of plasmonic nanostructures, and design and synthesis of the desired molecular candidates. Insights from this research will pave the path toward the development of technologies that will improve the way we harvest solar energy and drive chemical reactions and ultimately help transition the U.S. to a clean and sustainable society.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Unsupported single-atom-thick copper oxide monolayers

Oxide monolayers may present unique opportunities because of the great diversity of properties of these materials in bulk form. However, reports on oxide monolayers are still limited. Here we report the formation of single-atom-thick copper oxide layers with a square lattice both in graphene pores and on graphene substrates using aberration-corrected scanning transmission electron microscopy. First-principles calculations find that CuO is energetically stable and its calculated lattice spacing matches well with the measured value. Furthermore, free-standing copper oxide monolayers are predicted to be semiconductors with band gaps ~3 eV. The new wide-bandgap single-atom-thick copper oxide monolayers usher a new frontier to study the highly diverse family of two-dimensional oxides and explore their properties and their potential for new applications.

2D materials↗