Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “resilient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Approaches for Autonomous Peer to Peer Communication: For Resilient Community Microgrids

The final phase of the Islandable Communications task of the SECURE project consisted of integrating the islandable communications network into a microgrid simulation at NREL. Initially integration was planned for a microgrid implemented as a mix of simulation and physical hardware. As the project evolved, the microgrid became fully simulated. The simulation environment was structured to break out the communication paths that would pass over a communication network in a field demonstration. The Islandable Communication network was integrated into the simulation environment, allowing both a commercial cellular carrier and a Private LTE network to be evaluated. The microgrid simulation showed differences in performance and behavior when operating over the wireless networks (compared to operating over wired Ethernet in the lab). These differences point to further research opportunities to better understand how microgrid communication carried over real-world or impaired networks affects the microgrid system behavior.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data Analytics Methods to Measure Plant Outage Resilience

Every 18 or 24 months nuclear power plants (depending on plant configuration, pressurized or boiling water reactor respectively) undergo a period of outage where the plant is taken offline and a large number of maintenance and surveillance activities (that cannot be performed while plant is running) are performed in typically 2–3 weeks. Planning of a plant outage is very challenging since all the activities are required to be performed in the shortest amount of time given available resources (typically contractor crews hired for the duration of the outage). Consequently, plant outages can be costly due the actual loss of power generation and crew costs and, because of it, there is a need to maximize resource usage in the outage planning phase and reduce the risk of outage delays. This paper is addressing these needs by providing a set of analytical methods designed to analyze plant outage schedule and identify critical elements based on available resources (time and crews). These methods are based on natural language processing and optimization algorithms. In this respect, two classes of methods have been developed: one that focuses on the time resource and how variability in the time to complete outage tasks may impact outage delays, and one that minimizes the risk of outage delays by integrating available resources to assess when daily activities should be performed.

97 - MATHEMATICS AND COMPUTING↗

Capabilities for Water Sector Infrastructure Resilience - Prioritizing RD&D in a Target Rich, Resource Poor Sector

WSTB & Water Sector Security Program Expansion Objective: Incubate and shepherd a public-private consortium of joint seal US government sponsors and industry stakeholders to build out industrial control system (ICS) and operational technology (OT) architecture of the Idaho National Laboratory (INL) Water Security Test Bed (WSTB) asset to enable research, testing, and cyber workforce training related to evolving cyber-physical and physical vulnerabilities and threats in the water sector.

99 - GENERAL AND MISCELLANEOUS↗

Innovative Symmetrical Electrolyte Architecture Enables Ultra-Flat and Thermal Resilient Protonic Ceramic Electrochemical Cells

Protonic ceramic electrochemical cells (PCECs) represent a promising class of solid‐state energy conversion devices capable of high‐efficiency hydrogen production and power generation. However, the practical deployment of planar PCECs is fundamentally constrained by severe structural deformation and mechanical failure during fabrication, stemming from asymmetric shrinkage between the thin electrolyte and the thick NiO‐based support layer. Here, in this work, a functionally integrated, symmetry‐engineered double‐sided electrolyte (DE) design is unveiled, which not only suppresses thermally induced curvature but also unlocks significant gains in electrochemical performance and stability. This architecture intrinsically balances shrinkage dynamics across the cell bilaterally, enabling the fabrication of ultra‐flat 5 × 5 cm 2 cells with sub‐100 µm thickness variation. A numerical solid mechanics simulation is introduced to investigate and interpret this achievement. Beyond structural advantages, the DE configuration enhances the cell operational stability, delivering a low open‐circuit voltage degradation of 9.5 mV/100 h across 80 thermal cycles. This work establishes a compelling paradigm wherein architectural symmetry directly translates to both mechanical fidelity and functional enhancement, offering a promising route toward PCECs scale‐up.

08 - HYDROGEN↗

Emergent Degradation Phenomena Demonstrated on Resilient, Flexible, and Scalable Integrated Photoelectrochemical Cells

Photoelectrochemical (PEC) water splitting provides a pathway to generate sustainable clean fuels using the two most abundant resources on Earth: sunlight and water. Currently, most of the successful models of PEC cells are still fabricated on small scales near 1 cm 2 , which largely limits the mass deployment of solar-fuel production. Here, the scale-up to 8 cm 2 of an integrated PEC (IPEC) device is demonstrated and its performance compared to a 1 cm 2 IPEC cell, using state-of-the-art iridium and platinum catalysts with III–V photoabsorbers. The initial photocurrents at 1 sun are 8 and 7 mA cm -2 with degradation rates of 0.60 and 0.47 mA cm -2 day -1 , during unbiased operation for the 1 and 8 cm 2 devices, respectively. Additionally, evaluating under outdoor and indoor conditions at two U.S. National Laboratories reveals similar results, evidencing the reproducibility of this design's performance. Furthermore, the emerging degradation mechanisms during scale-up are investigated and the knowledge gained from this work will provide feedback to the broader community, since PEC device durability is a limiting factor in its potential future deployment.

25 ENERGY STORAGE↗

Water Splitting: Emergent Degradation Phenomena Demonstrated on Resilient, Flexible, and Scalable Integrated Photoelectrochemical Cells (Adv. Energy Mater. 48/2020)

We report Photoelectrochemical (PEC) water splitting provides a pathway to generate sustainable clean fuels using the two most abundant resources on Earth: sunlight and water. Currently, most of the successful models of PEC cells are still fabricated on small scales near 1 cm 2 , which largely limits the mass deployment of solar-fuel production. Here, the scale-up to 8 cm 2 of an integrated PEC (IPEC) device is demonstrated and its performance compared to a 1 cm 2 IPEC cell, using state-of-the-art iridium and platinum catalysts with III-V photoabsorbers. The initial photocurrents at 1 sun were 8 and 7 mA cm -2 with degradation rates of 0.60 and 0.47 mA cm -2 day -1 , during unbiased operation for the 1 and 8 cm 2 devices, respectively. Evaluating under outdoor and indoor conditions at two US National Laboratories revealed similar results, evidencing the reproducibility of this design’s performance. Furthermore, the emerging degradation mechanisms during scale-up are investigated and the knowledge gained from this work will provide feedback to the broader community, since PEC device durability is a limiting factor in its potential future deployment.

25 ENERGY STORAGE↗

Engineering Thermally Resilient and Kinetically Active Reversible Protonic Ceramic Cells via Interfacial Design

Achieving concurrent fast electrode kinetics and long-term thermo-mechanical durability remains a critical challenge for reversible protonic ceramic electrochemical cells (R-PCECs). Herein, we report an interfacial engineering strategy that integrates a perovs.kite-type PrBaRu0.1Co1.9O5+δ (PBRC) nanoparticle layer onto a PrBa0.5Sr0.5Co1.5Fe0.5O5+δ (PBSCF) substrate (PBRC-PBSCF), together with a modified pellet-assisted sintering approach to fabricate dense BaZr0.4Ce0.4Y0.1Yb0.1O3-δ (BZCYYb4411) electrolytes. The in situ reconstructed heterointerface enhances oxygen reduction/evolution reaction (ORR/OER) kinetics, promotes H2O adsorption/dissociation, and improves steam tolerance, as verified by electrochemical measurements and interfacial microstructural analyses. Density functional theory reveals that Ru-induced electronic modulation at the PBRC-PBSCF interface lowers the energy of oxygen vacancy formation and optimizes the position of the O 2p band center, thereby accelerating oxygen redox kinetics and stabilizing the interface. The resulting R-PCECs deliver an excellent peak power density of 1.112 W cm−2 and an electrolysis current density of −1.257 A cm−2 at 1.3 V in 3% H2O wet air at 600°C, with a reasonable faradaic efficiency. Furthermore, the cells demonstrate excellent stability, sustaining 100 h of thermal cycling (400–600°C, 200°C h−1) in both fuel cell and electrolysis modes, with 600 h of stability in electrolysis mode (600°C, −0.5 to −2 A cm−2).

30 DIRECT ENERGY CONVERSION↗

Systems Theory Principles and Complex Systems Engineering Concepts for Protection and Resilience in Critical Infrastructure: Lessons from the Nuclear Sector

Part of the Presidential Policy Directive 21 (PPD-21) (PPD 2013) mandate includes evaluating safety, security, and safeguards (or nonproliferation) mechanisms traditionally implemented within the nuclear reactors, materials, and waste sector of critical infrastructure—including a complex, dynamic set of risks and threats within an all-hazards approach. In response, research out of Sandia National Laboratories (Sandia) explores the ability of systems theory principles (hierarchy and emergence) and complex systems engineering concepts (multidomain interdependence) to better understand and address these risks and threats. Herein, this Sandia research explores the safety, safeguards, and security risks of three different nuclear sector-related activities—spent nuclear fuel transportation, small modular reactors, and portable nuclear power reactors—to investigate the complex and dynamic risk related to the PPD-21-mandated all-hazards approach. This research showed that a systems-theoretic approach can better identify inter-dependencies, conflicts, gaps, and leverage points across traditional safety, security, and safeguards hazard mitigation strategies in the nuclear reactors, materials, and waste sector. Resulting from this, mitigation strategies from applying systems theoretic principles and complex systems engineering concepts can be (1) designed to better capture interdependencies, (2) implemented to better align with real-world operational uncertainties, and (3) evaluated as a systems-level whole to better identify, characterize, and manage PPD-21's all hazards strategies.

42 ENGINEERING↗

Understanding Life History Diversity of a Wild Steelhead Population and Managing for Resiliency

Abstract Diversity in steelhead Oncorhynchus mykiss (anadromous Rainbow Trout) is often characterized by varying time spent in freshwater and saltwater environments. However, ontogenetic shifts are not often highlighted as an important diversity characteristic in salmonids. Larger water bodies can play a key role in population stability by buffering limited resources in smaller tributary systems. Based on freshwater and saltwater ages of adult steelhead in Fish Creek, Idaho, there were 12 different life history trajectories observed. Juvenile abundance varied from 12,083 (SE = 1,225.7) to 62,463 (SE = 1,753.8), with ages ranging from young of the year (age 0) to 4 years. Adult abundance fluctuated from 17 (SE < 0.1) to 499 (SE = 67.1), and total age of adults varied from 3 to 7 years. Diversity was most evident in juvenile movement and rearing strategies. We observed four types of movement and rearing pathways in which juveniles either directly migrated to the ocean from Fish Creek or resided for up to three winters in main-stem river habitat in the Clearwater River basin prior to ocean migration. Most juveniles emigrated in the fall at age 2, and most ocean-emigrating smolts were age 3. Subsequently, most juveniles resided for at least one additional winter period before ocean migration. Juvenile diversity was also reflected in adult ages; the mean proportion that spent 3 years in freshwater was 0.55 (SE = 0.03), and the mean proportion that spent 2 years in freshwater was 0.41 (SE = 0.03). Adult sex ratio was female biased (mean ± SE = 0.66 ± 0.02), with a higher proportion of females (0.89 ± 0.03) than males (0.65 ± 0.05) residing in the ocean for at least 2 years. Density-dependent mechanisms were evident in juvenile rearing habitat in Fish Creek for cohorts of high female abundance. Population productivity potentials can be met when tributary and main-stem rearing habitat can be utilized, and this will be essential in attaining recovery goals.

Dobos, Marika E.↗

Reliability of emergency and standby diesel generators: Impact on energy resiliency solutions

Emergency diesel generators are the most common form of backup power for critical loads when the grid fails and are most often deployed as stand-alone generators (<2000 kW) tied to individual buildings for hospitals, emergency services, military bases, ports, airports, industries, and commercial facilities. Understanding the finite reliability of emergency diesel generators during continuous operation is critical for energy planners, managers, and end-users. A new analysis of two large non-public emergency diesel generator operational data sets shows that commonly used reliability metrics are inadequate to predict the performance during a grid outage. Additional metrics addressing the likelihood of an emergency diesel generator to be available at the time an outage starts, successfully start and carry load, and constantly run for the duration of the outage are needed to predict the continuous run-time reliability of emergency diesel generators during a grid outage. This is the first analysis of the reliability of modern generators that follow standard maintenance protocols commonly used for backup power and these new metrics are shown to be dependent on the level of emergency diesel generator maintenance with values that can vary by more than an order of magnitude. Even using the new metrics for well-maintained emergency diesel generators, the analysis shows that the single emergency diesel generators configurations are only 80% likely to provide power for the duration of a two-week grid outage.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

Optimizing design and dispatch of a resilient renewable energy microgrid for a South African hospital

Lack of access to reliable energy is a major concern for countries in sub-Saharan Africa. The national grids are unable to consistently satisfy demand. Therefore, users turn to distributed generation systems in the form of back-up generators. However, such systems are usually designed based on a rule of thumb. We employ a mixed-integer linear programming model that considers several options such as renewable energy, combined heat and power, and storage technologies, in addition to those on-site, to provide optimal design and dispatch decisions that minimize total cost. We apply this model to a case study for a hospital in South Africa, considering its need for reliable electricity in light of multiple outages that might occur over the course of a year, as well as its high heating and cooling loads. Our results show that optimal design and dispatch decisions for the distributed generation system address reliability challenges, regardless of the time at which they occur. And, these solutions yield millions of dollars in savings, suggesting that technologies such as the absorption chiller may be overlooked in typical designs; its integration can reduce demand charges even in the absence of combined heat and power. We show that total cost is most sensitive to changes in site electrical demand, followed by capital cost, fuel cost, photovoltaic production, and monthly demand charges; changes in fuel cost primarily affect system sizes of combined heat and power and the absorption chiller, while photovoltaic system size is more sensitive to the changes in capital and fuel costs, photovoltaic resource availability, and hourly electrical demand. Finally, an outage simulator demonstrates the ability of our optimized system to sustain with no interruptions in power five-hour outages with probability 1.0 and ten-hour outages with probability 0.65, significant improvements over 0.5 and 0.0, respectively, under a business-as-usual case.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Corrigendum to “Cool Rooms for Indoor Heat Resilience: Evaluating Affordable Cooling Strategies in Heat-Stressed California Homes” [Building and Environment 287 (2026) 113877]

The authors regret an error in the acknowledgments section regarding the U.S. Department of Energy Solar Energy Technologies Office award number. The previously listed grant number, 2597–1625, was incorrect. The corrected acknowledgment should read: “This work was supported by the Assistant Secretary for Energy Efficiency and Renewable Energy, Office of Building Technologies of the United States Department of Energy (DOE), under Contract No. DE-AC02–05CH11231. This material is based upon work supported by the U.S. Department of Energy's Office of Energy Efficiency and Renewable Energy (EERE) under the Solar Energy Technologies Office Award Number DE-EE00040384. Any opinions, findings, and conclusions or recommendations expressed in this material are those of the author(s) and do not necessarily reflect the views of the Department of Energy.” The authors would like to apologise for any inconvenience caused.

Malik, Jeetika↗