Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reliability standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Recommendations for mass spectrometry data quality metrics for open access data(corollary to the Amsterdam principles)

Policies supporting the rapid and open sharing of proteomic data are being implemented by the leading journals in the field. The proteomics community is taking steps to ensure that data are made publicly accessible and are of high quality, a challenging task that requires the development and deployment of methods for measuring and documenting data quality metrics. On September 18, 2010, the U.S. National Cancer Institute (NCI) convened the 'International Workshop on Proteomic Data Quality Metrics' in Sydney, Australia, to identify and address issues facing the development and use of such methods for open access proteomics data. The stakeholders at the workshop enumerated the key principles underlying a framework for data quality assessment in mass spectrometry data that will meet the needs of the search community, journals, funding agencies, and data repositories. Attendees discussed and agreed upon two primary needs for the wide use of quality metrics: (i)an evolving list of comprehensive quality metrics and (ii)standards accompanied by software analytics. Attendees stressed the importance of increased education and training programs to promote reliable protocols in proteomics. This workshop report explores the historic precedents, key discussions, and necessary next steps to enhance the quality of open access data. By agreement, this article is published simultaneously in Proteomics, Proteomics Clinical Applications, Journal of Proteome Research, and Molecular and Cellular Proteomics, as a public service to the research community.The peer review process was a coordinated effort conducted by a panel of referees selected by the journals.

59 BASIC BIOLOGICAL SCIENCES↗

Optical second harmonic generation in anisotropic multilayers with complete multireflection of linear and nonlinear waves using ♯SHAARP.ml package

Abstract Optical second harmonic generation (SHG) is a nonlinear optical effect widely used for nonlinear optical microscopy and laser frequency conversion. Closed-form analytical solution of the nonlinear optical responses is essential for evaluating materials whose optical properties are unknown a priori. A recent open-source code, ♯SHAARP. si , can provide such closed form solutions for crystals with arbitrary symmetries, orientations, and anisotropic properties at a single interface. However, optical components are often in the form of slabs, thin films on substrates, and multilayer heterostructures with multiple reflections of both the fundamental and up to ten different SHG waves at each interface, adding significant complexity. Many approximations have therefore been employed in the existing analytical approaches, such as slowly varying approximation, weak reflection of the nonlinear polarization, transparent medium, high crystallographic symmetry, Kleinman symmetry, easy crystal orientation along a high-symmetry direction, phase matching conditions and negligible interference among nonlinear waves, which may lead to large errors in the reported material properties. To avoid these approximations, we have developed an open-source package named Second Harmonic Analysis of Anisotropic Rotational Polarimetry in Multilayers (♯SHAARP. ml ). The reliability and accuracy are established by experimentally benchmarking with both the SHG polarimetry and Maker fringes using standard and commonly used nonlinear optical materials as well as twisted 2-dimensional heterostructures.

36 MATERIALS SCIENCE↗

Methods and preliminary measurement results of liquid Li wettability

A test of lithium wettability was performed in high vacuum (< 3 × 10{sup −4} Pa). High magnification images of Li droplets on stainless steel substrates were produced and processed using the MATLAB{sup ®} program to obtain clear image edge points. In contrast to the more standard “θ/2” or polynomial fitting methods, ellipse fitting of the complete Li droplet shape resulted in reliable contact angle measurements over a wide range of contact angles. Using the ellipse fitting method, it was observed that the contact angle of a liquid Li droplet on a stainless steel substrate gradually decreased with increasing substrate temperature. The critical wetting temperature of liquid Li on stainless steel was observed to be about 290 °C.

36 MATERIALS SCIENCE↗

Development of BATAN’s texture diffractometer (current status)

Texture Diffractometer, called DN2, is one of neutron diffractometers in BATAN which is dedicated for texture measurement using neutron diffraction method. To obtain better performance of the DN2, a flight tube goniometer have been installed between the monochromator and sample position. By adjusting the flight tube goniometer, defocusing effect at direct beam and background effect could be reduced significantly. Some experiments have been carried out to characterize DN2 performance. The flight tube goniometer alignment and neutron wavelength calibration were characterized using silicon standard sample Si640d. Data refinement of diffraction pattern was analyzed using MAUD software and it is obtained reliability factor with background, R{sub wpb}, reduced significantly, from 42.53 % to 19.36 % after setting of flight tube goniometer. Reliability factor without background (R{sub wp}) was reduced from 27.41% to 21.36%. Calibrated of neutron wavelengh, λ = 1,2799 Angstrom is obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The accuracies of effective interactions in downfolding coupled-cluster approaches for small-dimensionality active spaces

Here, this paper evaluates the accuracy of the Hermitian form of the downfolding procedure using the double unitary coupled cluster (DUCC) ansatz on the benchmark systems of linear chains of hydrogen atoms, H6 and H8. The computational infrastructure employs the occupation-number-representation codes to construct the matrix representation of arbitrary second-quantized operators, allowing for the exact representation of exponentials of various operators. The tests demonstrate that external amplitudes from standard single-reference coupled cluster methods that sufficiently describe external (out-of-active-space) correlations reliably parameterize the Hermitian downfolded effective Hamiltonians in the DUCC formalism. The results show that this approach can overcome the problems associated with losing the variational character of corresponding energies in the corresponding SR-CC theories.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Implementation of Advanced Grid Support Functionalities by Smart Operation of Residential Loads with low Cost Converter Interface

This paper investigates a grid-supportive load concept for small-scale residential appliances, focusing on a residential refrigerator. Power consumption is adjusted based on grid conditions to achieve IEEE-1547 grid support functions. Two key aspects are presented: a low-cost refrigerator converter with Lyapunov energy function-based local controllers for speed control, and the impact on a standard microgrid system, demonstrating advanced grid support from the load side. This method enhances grid resilience and reliability and can be extended to other residential loads. The study contributes to efficient and robust grid-supportive load management systems, showing promising performance. This approach has the potential to improve overall grid stability and can be adapted for various types of residential appliances. The modeling and simulations in MATLAB/Simulink and PLECS confirm the feasibility and effectiveness of the proposed solution. Future work will explore real-world implementation and scalability of this concept for broader applications.

grid supportive loads (GSL)↗

Measuring neutron spectra in radiotherapy using the nested neutron spectrometer

Purpose: Out-of-field neutron doses resulting from photonuclear interactions in the head of a linear accelerator pose an iatrogenic risk to patients and an occupational risk to personnel during radiotherapy. To quantify neutron production, in-room measurements have traditionally been carried out using Bonner sphere systems (BSS) with activation foils and TLDs. In this work, a recently developed active detector, the nested neutron spectrometer (NNS), was tested in radiotherapy bunkers. Methods: The NNS is designed for easy handling and is more practical than the traditional BSS. Operated in current-mode, the problem of pulse pileup due to high dose-rates is overcome by measuring current, similar to an ionization chamber. In a bunker housing a Varian Clinac 21EX, the performance of the NNS was evaluated in terms of reproducibility, linearity, and dose-rate effects. Using a custom maximum-likelihood expectation–maximization algorithm, measured neutron spectra at various locations inside the bunker were then compared to Monte Carlo simulations of an identical setup. In terms of dose, neutron ambient dose equivalents were calculated from the measured spectra and compared to bubble detector neutron dose equivalent measurements. Results: The NNS-measured spectra for neutrons at various locations in a treatment room were found to be consistent with expectations for both relative shape and absolute magnitude. Neutron fluence-rate decreased with distance from the source and the shape of the spectrum changed from a dominant fast neutron peak near the Linac head to a dominant thermal neutron peak in the moderating conditions of the maze. Monte Carlo data and NNS-measured spectra agreed within 30% at all locations except in the maze where the deviation was a maximum of 40%. Neutron ambient dose equivalents calculated from the authors’ measured spectra were consistent (one standard deviation) with bubble detector measurements in the treatment room. Conclusions: The NNS may be used to reliably measure the neutron spectrum of a radiotherapy beam in less than 1 h, including setup and data unfolding. This work thus represents a new, fast, and practical method for neutron spectral measurements in radiotherapy.

60 APPLIED LIFE SCIENCES↗

SU-F-J-36: Comparison of Ball Bearing and Iso-Cube Phantoms for KV-MV Iso-Center Coincidence Check

Purpose: To compare two different quality assurance tools for kV-MV isocenter coincidence check. Methods: Ball-Bearing device (BBD) (Elekta) provided along with a CBCT equipped LINAC and isocenter cube phantom (CP) (a commercial product of Modus Medical Devices) are utilized to check the coincidence between the MV and kV beam isocenters. The microstepping meter of the BBD allows precision adjustment to better than 0.01mm in three directions. The BBD is aligned to the MV-isocenter with the lasers and followed by taking MV-images of at two collimator angles at each cardinal gantry, then its position adjusted. This process takes in iterative steps until 0.25mm tolerance is achieved. Four planar kV-images are taken at cardinal angles and deviations of BBD position from kVisocenter are evaluated. CP is positioned on the couch with the lasers at known offset from the isocenter. CBCT is utilized to set the cube to its kV isocenter with the precision of linac’s couch (1mm). MV-images are taken at various gantry, collimator, and couch angles and evaluated with the CP manufacturer provided QA software to determine coincidence of the 6mm steel ball at cube center with MV-isocenter. Three sets of measurements, one after another, were performed on the same day for each phantom on the same linac. Results: Assuming little variation between kV and MV isocenters in a short time, BBD measurements are more reproducible than CP. With comparable conditions both methods agree within 0.5 mm in each direction, while for BBD average standard deviation was 0.07mm and for iso-cube 0.3mm. Conclusion: Since BBD is more reliable and its results are more reproducible, it should be used during the monthly QA. Since CP is a more efficient device, it should be used for daily QA. A comparison study between the two devices should be periodically performed.

60 APPLIED LIFE SCIENCES↗

Second Generation Novel High Temperature Commercial Receiver & Low Cost High Performance Mirror Collector for Parabolic Solar Trough

Norwich Technologies (NT) is developing a disruptively superior solar field for trough concentrating solar power (CSP). Troughs are the leading CSP technology (85% of installed capacity), being highly deployable and similar to photovoltaic (PV) systems for siting. NT has developed the SunTrap receiver, a disruptive alternative to vacuum-tube concentrating solar power (CSP) receivers, a market currently dominated by the Schott PTR-70. The SunTrap receiver will (1) operate at higher temperature (T) by using an insulated, recessed radiation-collection system to overcome the energy losses that plague vacuum-tube receivers at high T, (2) decrease acquisition costs via simpler structure, and (3) dramatically increase reliability by eliminating vacuum. It offers comparable optical efficiency with thermal loss reduction from ≥ 26% (at presently standard T) to ≥ 55% (at high T), lower acquisition costs, and near-zero O&M costs.

14 SOLAR ENERGY↗

Fielding and analyzing performance of a prototype high voltage output gas switch for Saturn

Timing spread between the thirty-six Saturn modules affects peak electrical power delivered to the Bremsstrahlung diode and can affect vacuum power flow and impedance behavior of the load. To reduce the module spread, a new megavolt gas-insulated closing switch was developed employing design techniques developed for the Z-machine laser triggered switches while retaining Saturn’s simpler electrical triggering. Two modules were temporarily outfitted with the new switches and used separately into local resistive loads (instead of the usual Saturn electron beam load). A reliable operating point and switch time jitter at that point were the goals of the experiments. The target switch reliability is less than one pre-fire in one thousand switch-shots, and a timing standard deviation of 4 nanoseconds. The switches were able to meet both requirements but the number of tests at the chosen point are limited.

43 PARTICLE ACCELERATORS↗

Reimagining Energy Efficiency Resource Standards

Energy Efficiency Resource Standards (EERS) are a long-standing policy used to advance state goals and priorities, such as reliability, affordability and decarbonization. They ensure cost-effective energy efficiency is used to lower energy consumption, reduce peak demand, and enable grid flexibility. Adapting EERS through strategic design, and integrating EERS into broader energy plans and policies, can help states optimize their approach to meet modern and evolving power system needs and achieve sustainable energy outcomes. This report examines how states consider energy efficiency in the context of four policy priorities: providing grid benefits, addressing load growth, reducing emissions, and promoting affordability. It provides examples of states that are pursuing these priorities, reviews the role of energy efficiency in them and identifies opportunities to further promote energy efficiency alongside the priorities. Decisionmakers and stakeholders can draw directly from these examples and findings to design an EERS that maximizes co-benefits, captures synergies, and promotes consideration of the all the possible solutions to advance their goals.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Evaluation of IEC 62443 Standard Gaps for Electric Grid Substation Model Use Case

This report presents an evaluation of the IEC 62443 standards in the context of electric grid substations, as part of a collaborative effort among Sandia National Laboratories (SNL), Idaho National Laboratory (INL), and the National Renewable Energy Laboratory (NREL). The primary objective is to assess the applicability of these standards to enhance cybersecurity measures for industrial automation and control systems (IACS) within the energy sector. The evaluation identifies strengths, such as the scalability of security levels and the structured lifecycle guidance provided by IEC 62443. However, it also highlights significant gaps, including limited integration of physical security, insufficient guidance for legacy systems, and challenges in addressing emerging threats like supply chain vulnerabilities. Recommendations for refining the standards are proposed, including the need for tailored guidance for securing legacy systems, integrating physical security with cybersecurity frameworks, and enhancing interoperability across multi-vendor environments. By addressing these gaps, the IEC 62443 standards can be strengthened to ensure comprehensive cybersecurity for electric grid substations, thereby supporting the resilience and reliability of critical energy infrastructure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of design data for graphite reinforced epoxy and polyimide composites

Processing techniques and design data were characterized for a graphite/epoxy composite system that is useful from 75 K to 450 K, and a graphite/polyimide composite system that is useful from 75 K to 589 K. The Monsanto 710 polyimide resin was selected as the resin to be characterized and used with the graphite fiber reinforcement. Material was purchased using the prepreg specification for the design data generation for both the HT-S/710 and HM-S/710 graphite/polyimide composite system. Lamina and laminate properties were determined at 75 K, 297 K, and 589 K. The test results obtained on the skin-stringer components proved that graphite/polyimide composites can be reliably designed and analyzed much like graphite/epoxy composites. The design data generated in the program includes the standard static mechanical properties, biaxial strain data, creep, fatigue, aging, and thick laminate data.

Scheck, W. G.↗

Development of Statistical Process Control Methodology for an Environmentally Compliant Surface Cleaning Process in a Bonding Laboratory

Bonding labs at both MSFC and the northern Utah production plant prepare bond test specimens which simulate or witness the production of NASA's Reusable Solid Rocket Motor (RSRM). The current process for preparing the bonding surfaces employs 1,1,1-trichloroethane vapor degreasing, which simulates the current RSRM process. Government regulations (e.g., the 1990 Amendments to the Clean Air Act) have mandated a production phase-out of a number of ozone depleting compounds (ODC) including 1,1,1-trichloroethane. In order to comply with these regulations, the RSRM Program is qualifying a spray-in-air (SIA) precision cleaning process using Brulin 1990, an aqueous blend of surfactants. Accordingly, surface preparation prior to bonding process simulation test specimens must reflect the new production cleaning process. The Bonding Lab Statistical Process Control (SPC) program monitors the progress of the lab and its capabilities, as well as certifies the bonding technicians, by periodically preparing D6AC steel tensile adhesion panels with EA-91 3NA epoxy adhesive using a standardized process. SPC methods are then used to ensure the process is statistically in control, thus producing reliable data for bonding studies, and identify any problems which might develop. Since the specimen cleaning process is being changed, new SPC limits must be established. This report summarizes side-by-side testing of D6AC steel tensile adhesion witness panels and tapered double cantilevered beams (TDCBs) using both the current baseline vapor degreasing process and a lab-scale spray-in-air process. A Proceco 26 inches Typhoon dishwasher cleaned both tensile adhesion witness panels and TDCBs in a process which simulates the new production process. The tests were performed six times during 1995, subsequent statistical analysis of the data established new upper control limits (UCL) and lower control limits (LCL). The data also demonstrated that the new process was equivalent to the vapor degreasing process.

Hutchens, Dale E.↗

Effect of Liquid Penetrant Sensitivity on Probability of Detection

The objective of the task is to investigate the effect of liquid penetrant sensitivity level on probability of detection (POD) of cracks in various metals. NASA-STD-5009 currently requires the use of only sensitivity level 4 liquid penetrants for NASA Standard Level inspections. This requirement is based on the fact that the data used to establish the reliably detectable flaw sizes penetrant inspection was from studies performed in the 1970s using penetrant deemed to be equivalent only to modern day sensitivity level 4 penetrants. However, many NDE contractors supporting NASA Centers routinely use sensitivity level 3 penetrants. Because of the new NASA-STD-5009 requirement, these contractors will have to either shift to sensitivity level 4 penetrants or perform formal POD demonstration tests to qualify their existing process. We propose a study to compare the POD generated for two penetrant manufactures, Sherwin and Magnaflux, and for the two most common penetrant inspection methods, water washable and post emulsifiable, hydrophilic. NDE vendors local to GSFC will be employed. A total of six inspectors will inspect a set of crack panels with a broad range of fatigue crack sizes. Each inspector will perform eight inspections of the panel set using the combination of methods and sensitivity levels described above. At least one inspector will also perform multiple inspections using a fixed technique to investigate repeatability. The hit/miss data sets will be evaluated using both the NASA generated DOEPOD software and the MIL-STD-1823 software.

Parker, Bradford H.↗

Prediction Interval Development for Wind-Tunnel Balance Check-Loading

Results from the Facility Analysis Verification and Operational Reliability project revealed a critical gap in capability in ground-based aeronautics research applications. Without a standardized process for check-loading the wind-tunnel balance or the model system, the quality of the aerodynamic force data collected varied significantly between facilities. A prediction interval is required in order to confirm a check-loading. The prediction interval provides an expected upper and lower bound on balance load prediction at a given confidence level. A method has been developed which accounts for sources of variability due to calibration and check-load application. The prediction interval method of calculation and a case study demonstrating its use is provided. Validation of the methods is demonstrated for the case study based on the probability of capture of confirmation points.

Landman, Drew↗

Effectiveness of Redundant Communications Systems in Maintaining Operational Control of Small Unmanned Aircraft

As a part of NASA’s Unmanned Aircraft System (UAS) Traffic Management (UTM) research, a test was performed to evaluate the effectiveness of the redundant Command and Control (C2) communications system for maintaining operational control of small UAS in the airspace over a rural area. In the test, operators set up a primary and a secondary UAS C2 communications system, sent a maneuver command to an Unmanned Aircraft (UA) with and without a functioning primary system, then verified the execution of the sent command to confirm the operator control. Operators reported that the tested redundancy configurations were effective in maintaining operational control in the test airspace over rural locations. Since the next phase of UTM research focuses on operations in an urban area where an increased level of Radio Frequency (RF) activities occur compared to a rural area, four recommendations are provided to sustain the effectiveness of redundancy in urban operations. First, the operator should not include C2 systems that use the industrial, scientific, and medical (ISM) radio bands in redundancy configurations. Second, the operator should verify the RF characteristics of the intended operation area and examine the area’s radio noise floor. Third, the operator should monitor the availability, quality, and reliability of communications services used by a redundant system. Fourth, the small UAS community should adopt a standard set of contingency steps to handle the loss of C2 communications so that such events are managed in a consistent manner across the airspace. The insights from the test will be used to accommodate the FAA’s UAS integration effort.

Jung, Jaewoo↗