Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “random testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Assessment of Interfraction Patient Setup for Head-and-Neck Cancer Intensity Modulated Radiation Therapy Using Multiple Computed Tomography-Based Image Guidance

Purpose: Various image guidance systems are commonly used in conjunction with intensity modulated radiation therapy (IMRT) in head-and-neck cancer irradiation. The purpose of this study was to assess interfraction patient setup variations for 3 computed tomography (CT)-based on-board image guided radiation therapy (IGRT) modalities. Methods and Materials: A total of 3302 CT scans for 117 patients, including 53 patients receiving megavoltage cone-beam CT (MVCBCT), 29 receiving kilovoltage cone-beam CT (KVCBCT), and 35 receiving megavoltage fan-beam CT (MVFBCT), were retrospectively analyzed. The daily variations in the mediolateral (ML), craniocaudal (CC), and anteroposterior (AP) dimensions were measured. The clinical target volume-to-planned target volume (CTV-to-PTV) margins were calculated using 2.5Σ + 0.7 σ, where Σ and σ were systematic and random positioning errors, respectively. Various patient characteristics for the MVCBCT group, including weight, weight loss, tumor location, and initial body mass index, were analyzed to determine their possible correlation with daily patient setup. Results: The average interfraction displacements (± standard deviation) in the ML, CC, and AP directions were 0.5 ± 1.5, −0.3 ± 2.0, and 0.3 ± 1.7 mm (KVCBCT); 0.2 ± 1.9, −0.2 ± 2.4, and 0.0 ± 1.7 mm (MVFBCT); and 0.0 ± 1.8, 0.5 ± 1.7, and 0.8 ± 3.0 mm (MVCBCT). The day-to-day random errors for KVCBCT, MVFBCT, and MVCBCT were 1.4-1.6, 1.7, and 2.0-2.1 mm. The interobserver variations were 0.8, 1.1, and 0.7 mm (MVCBCT); 0.5, 0.4, and 0.8 mm (MVFBCT); and 0.5, 0.4, and 0.6 mm (KVCBCT) in the ML, CC, and AP directions, respectively. The maximal calculated uniform CTV-to-PTV margins were 5.6, 6.9, and 8.9 mm for KVCBCT, MVFBCT, and MVCBCT, respectively. For the evaluated patient characteristics, the calculated margins for different patient parameters appeared to differ; analysis of variance (ANOVA) and/or t test analysis found no statistically significant setup difference in any direction. Conclusions: Daily random setup errors and CTV-to-PTV margins for treatment of head-and-neck cancer were affected by imaging quality. Our data indicated that larger margins were associated with MVFBCT and MVCBCT, compared with smaller margins for KVCBCT. IGRT modalities with better image quality are encouraged in clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A 20 Gbps PAM4 data transmitter ASIC for particle physics experiments

We present the design and test results of a novel data transmitter ASIC operating up to 20.48 Gbps with 4-level Pulse-Amplitude-Modulation (PAM4) for particle physics experiments. This ASIC, named GBS20, is fabricated in a 65 nm CMOS technology. Two serializers share a 5.12 GHz Phase Locked Loop (PLL) clock. The outputs from the serializers are combined into a PAM4 signal that directly drives a Vertical-Cavity-Surface-Emitting-Laser (VCSEL). The input data channels, each at 1.28 Gbps, are scrambled with an internal 2$^{7}$-1 Pseudo-Random Binary Sequence (PRBS), which also serves as a frame aligner. GBS20 is tested to work at 10.24 and 20.48 Gbps with a VCSEL-based Transmitter-Optical-Subassembly (TOSA). The power consumption of GBS20 is below 238 mW and reduced to 164 mW in the low-power mode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preventing Failures By Dataset Shift Detection in Safety-Critical Graph Applications

Dataset shift refers to the problem where the input data distribution may change over time (e.g., between training and test stages). Since this can be a critical bottleneck in several safety-critical applications such as healthcare, drug-discovery, etc., dataset shift detection has become an important research issue in machine learning. Though several existing efforts have focused on image/video data, applications with graph-structured data have not received sufficient attention. Therefore, in this paper, we investigate the problem of detecting shifts in graph structured data through the lens of statistical hypothesis testing. Specifically, we propose a practical two-sample test based approach for shift detection in large-scale graph structured data. Our approach is very flexible in that it is suitable for both undirected and directed graphs, and eliminates the need for equal sample sizes. Using empirical studies, we demonstrate the effectiveness of the proposed test in detecting dataset shifts. We also corroborate these findings using real-world datasets, characterized by directed graphs and a large number of nodes.

97 MATHEMATICS AND COMPUTING↗

Template-based automatic breast segmentation on MRI by excluding the chest region

Purpose: Methods for quantification of breast density on MRI using semiautomatic approaches are commonly used. In this study, the authors report on a fully automatic chest template-based method. Methods: Nonfat-suppressed breast MR images from 31 healthy women were analyzed. Among them, one case was randomly selected and used as the template, and the remaining 30 cases were used for testing. Unlike most model-based breast segmentation methods that use the breast region as the template, the chest body region on a middle slice was used as the template. Within the chest template, three body landmarks (thoracic spine and bilateral boundary of the pectoral muscle) were identified for performing the initial V-shape cut to determine the posterior lateral boundary of the breast. The chest template was mapped to each subject's image space to obtain a subject-specific chest model for exclusion. On the remaining image, the chest wall muscle was identified and excluded to obtain clean breast segmentation. The chest and muscle boundaries determined on the middle slice were used as the reference for the segmentation of adjacent slices, and the process continued superiorly and inferiorly until all 3D slices were segmented. The segmentation results were evaluated by an experienced radiologist to mark voxels that were wrongly included or excluded for error analysis. Results: The breast volumes measured by the proposed algorithm were very close to the radiologist's corrected volumes, showing a % difference ranging from 0.01% to 3.04% in 30 tested subjects with a mean of 0.86% ± 0.72%. The total error was calculated by adding the inclusion and the exclusion errors (so they did not cancel each other out), which ranged from 0.05% to 6.75% with a mean of 3.05% ± 1.93%. The fibroglandular tissue segmented within the breast region determined by the algorithm and the radiologist were also very close, showing a % difference ranging from 0.02% to 2.52% with a mean of 1.03% ± 1.03%. The total error by adding the inclusion and exclusion errors ranged from 0.16% to 11.8%, with a mean of 2.89% ± 2.55%. Conclusions: The automatic chest template-based breast MRI segmentation method worked well for cases with different body and breast shapes and different density patterns. Compared to the radiologist-established truth, the mean difference in segmented breast volume was approximately 1%, and the total error by considering the additive inclusion and exclusion errors was approximately 3%. This method may provide a reliable tool for MRI-based segmentation of breast density.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Flight test technique for evaluation of gust load alleviation analysis methodology

A technique for gust load alleviation (GLA) flight testing that will approximate a turbulence-like excitation of the wing has been devised. An artificial excitation is produced by randomly deflecting inboard control surfaces on the wing, thereby producing incremental loads on the wing. This presentation covers the background and development of the flight test technique and analyses performed to date.

Perry, B., III↗

A Microfabricated Involute-Foil Regenerator for Stirling Engines

A segmented involute-foil regenerator has been designed, microfabricated and tested in an oscillating-flow rig with excellent results. During the Phase I effort, several approximations of parallel-plate regenerator geometry were chosen as potential candidates for a new microfabrication concept. Potential manufacturers and processes were surveyed. The selected concept consisted of stacked segmented-involute-foil disks (or annular portions of disks), originally to be microfabricated from stainless-steel via the LiGA (lithography, electroplating, and molding) process and EDM. During Phase II, re-planning of the effort led to test plans based on nickel disks, microfabricated via the LiGA process, only. A stack of nickel segmented-involute-foil disks was tested in an oscillating-flow test rig. These test results yielded a performance figure of merit (roughly the ratio of heat transfer to pressure drop) of about twice that of the 90 percent random fiber currently used in small approx.100 W Stirling space-power convertors-in the Reynolds Number range of interest (50 to 100). A Phase III effort is now underway to fabricate and test a segmented-involute-foil regenerator in a Stirling convertor. Though funding limitations prevent optimization of the Stirling engine geometry for use with this regenerator, the Sage computer code will be used to help evaluate the engine test results. Previous Sage Stirling model projections have indicated that a segmented-involute-foil regenerator is capable of improving the performance of an optimized involute-foil engine by 6 to 9 percent; it is also anticipated that such involute-foil geometries will be more reliable and easier to manufacture with tight-tolerance characteristics, than random-fiber or wire-screen regenerators. Beyond the near-term Phase III regenerator fabrication and engine testing, other goals are (1) fabrication from a material suitable for high temperature Stirling operation (up to 850 C for current engines; up to 1200 C for a potential engine-cooler for a Venus mission), and (2) reduction of the cost of the fabrication process to make it more suitable for terrestrial applications of segmented involute foils. Past attempts have been made to use wrapped foils to approximate the large theoretical figures of merit projected for parallel plates. Such metal wrapped foils have never proved very successful, apparently due to the difficulties of fabricating wrapped-foils with uniform gaps and maintaining the gaps under the stress of time-varying temperature gradients during start-up and shut-down, and relatively-steady temperature gradients during normal operation. In contrast, stacks of involute-foil disks, with each disk consisting of multiple involute-foil segments held between concentric circular ribs, have relatively robust structures. The oscillating-flow rig tests of the segmented-involute-foil regenerator have demonstrated a shift in regenerator performance strongly in the direction of the theoretical performance of ideal parallel-plate regenerators.

Tew, Roy↗

Antibacterial dental adhesive resins containing nitrogen-doped titanium dioxide nanoparticles

The development of dental adhesive resins with long-lasting antibacterial properties is a possible solution to overcome the problem of secondary caries in modern adhesive dentistry.Objectives: (i) Synthesis and characterization of nitrogen-doped titanium dioxide nanoparticles (N_TiO 2 ), (ii) topographical, compositional and wettability characterization of thin-films (unaltered and experimental) and, (iii) antibacterial efficacy of N_TiO 2 -containing dental adhesives against Streptococcus mutans biofilms.Materials and methods: Nanoparticles were synthesized and characterized using different techniques. Specimens (diameter = 12 mm, thickness ≅ 15 μm) of OptiBond Solo Plus (Kerr Corp., USA) and experimental adhesives [50, 67 and 80% (v/v)] were fabricated, photopolymerized (1000 mW/cm 2 , 1 min) and UV-sterilized (254 nm, 800,000 μJ/cm 2 ) for microscopy, spectroscopy, wettability and antibacterial testing. Wettability was assessed with a contact angle goniometer by dispensing water droplets (2 μL) onto four random locations of each specimen (16 drops/group). Drop profiles were recorded (1 min, 25 frames/s, 37 °C) and contact angles were calculated at time = 0 s (θ INITIAL ) and time = 59 s (θ FINAL ). Antibacterial testing was performed by growing S. mutans (UA159-ldh, JM10) biofilms for either 3 or 24 h (anaerobic conditions, 37 °C) with or without continuous light irradiation (410 ± 10 nm, 3 h = 38.75 J/cm 2 , 24 h = 310.07 J/cm 2 ) against the surfaces of sterile specimens.Results: N_TiO 2 was successfully prepared using solvothermal methods. Doped-nanoparticles displayed higher light absorption levels when compared to undoped titania. Experimental adhesives demonstrated superior antibacterial efficacy in dark conditions.Conclusions: The findings presented herein suggest that N_TiO 2 is a feasible antibacterial agent against cariogenic biofilms.

36 MATERIALS SCIENCE↗

Transcranial Direct Current Stimulation (tDCS) Improves Empathy and Recognition of Facial Emotions Conveying Threat in Adults with Autism Spectrum Disorder (ASD): A Randomized Controlled Pilot Study

Introduction: Empathy is critical for human interactions to become shared and meaningful, and it is facilitated by the expression and processing of facial emotions. Deficits in empathy and facial emotion recognition are associated with individuals with autism spectrum disorder (ASD), with specific concerns over inaccurate recognition of facial emotion expressions conveying a threat. Yet, the number of evidenced interventions for facial emotion recognition and processing (FERP), emotion, and empathy remains limited, particularly for adults with ASD. Transcranial direct current stimulation (tDCS), a noninvasive brain stimulation, may be a promising treatment modality to safely accelerate and/or enhance treatment interventions to increase their efficacy. Methods: This study investigates the effectiveness of FERP, emotion, and empathy treatment interventions paired with tDCS for adults with ASD. Differences in scores on the Empathy Quotient (EQ) and on a FERP test were predicted for verum tDCS when compared to sham. Verum/sham tDCS was randomly assigned in a within-subjects, double-blinded design in adults with ASD without intellectual disability. Results: Verum tDCS significantly improved EQ scores and FERP scores for emotions that conveyed threat. Conclusions: These results suggest the potential for increasing the efficacy of treatment interventions by pairing them with tDCS for individuals with ASD.

59 BASIC BIOLOGICAL SCIENCES↗

SU-G-TeP1-04: Deriving Spot Shape Criteria for Proton Pencil Beam Scanning

Purpose: The shape of a single beam in proton PBS influences the resulting dose distribution. Spot profiles are modelled as two-dimensional Gaussian (single/ double) distributions in treatment planning systems (TPS). Impact of slight deviations from an ideal Gaussian on resulting dose distributions is typically assumed to be small due to alleviation by multiple Coulomb scattering (MCS) in tissue and superposition of many spots. Quantitative limits are however not clear per se. Methods: A set of 1250 deliberately deformed profiles with sigma=4 mm for a Gaussian fit were constructed. Profiles and fit were normalized to the same area, resembling output calibration in the TPS. Depth-dependent MCS was considered. The deviation between deformed and ideal profiles was characterized by root-mean-squared deviation (RMSD), skewness/ kurtosis (SK) and full-width at different percentage of maximum (FWxM). The profiles were convolved with different fluence patterns (regular/ random) resulting in hypothetical dose distributions. The resulting deviations were analyzed by applying a gamma-test. Results were compared to measured spot profiles. Results: A clear correlation between pass-rate and profile metrics could be determined. The largest impact occurred for a regular fluence-pattern with increasing distance between single spots, followed by a random distribution of spot weights. The results are strongly dependent on gamma-analysis dose and distance levels. Pass-rates of >95% at 2%/2 mm and 40 mm depth (=70 MeV) could only be achieved for RMSD<10%, deviation in FWxM at 20% and root of quadratic sum of SK <0.8. As expected the results improve for larger depths. The trends were well resembled for measured spot profiles. Conclusion: All measured profiles from ProBeam sites passed the criteria. Given the fact, that beam-line tuning can result shape distortions, the derived criteria represent a useful QA tool for commissioning and design of future beam-line optics.

07 ISOTOPE AND RADIATION SOURCES↗

Shake test results of the MDHC test stand in the 40- by 80-foot wind tunnel

A shake test was conducted to determine the modal properties of the MDHC (McDonnell Douglas Helicopter Company) test stand installed in the 40- by 80- Foot Wind Tunnel at Ames Research Center. The shake test was conducted for three wind-tunnel balance configurations with and without balance dampers, and with the snubber engagement to lock the balance frame. A hydraulic shaker was used to apply random excitation at the rotor hub in the longitudinal and lateral directions. A GenRad 2515 computer-aided test system computed the frequency response functions at the rotor hub and support struts. From these response functions, the modal properties, including the natural frequency, damping ratio, and mode shape were calculated. The critical modes with low damping ratios are identified as the test-stand second longitudinal mode for the dampers-off configuration, the test-stand yaw mode for the dampers-on configuration, and the test stand first longitudinal mode for the balance-frame locked configuration.

Lau, Benton H.↗

Emperical Tests of Acceptance Sampling Plans

Acceptance sampling is a quality control procedure applied as an alternative to 100% inspection. A random sample of items is drawn from a lot to determine the fraction of items which have a required quality characteristic. Both the number of items to be inspected and the criterion for determining conformance of the lot to the requirement are given by an appropriate sampling plan with specified risks of Type I and Type II sampling errors. In this paper, we present the results of empirical tests of the accuracy of selected sampling plans reported in the literature. These plans are for measureable quality characteristics which are known have either binomial, exponential, normal, gamma, Weibull, inverse Gaussian, or Poisson distributions. In the main, results support the accepted wisdom that variables acceptance plans are superior to attributes (binomial) acceptance plans, in the sense that these provide comparable protection against risks at reduced sampling cost. For the Gaussian and Weibull plans, however, there are ranges of the shape parameters for which the required sample sizes are in fact larger than the corresponding attributes plans, dramatically so for instances of large skew. Tests further confirm that the published inverse-Gaussian (IG) plan is flawed, as reported by White and Johnson (2011).

White, K. Preston, Jr.↗

Multilevel Method for Modeling Large-Scale Networks

Understanding the behavior of real complex networks is of great theoretical and practical significance. It includes developing accurate artificial models whose topological properties are similar to the real networks, generating the artificial networks at different scales under special conditions, investigating a network dynamics, reconstructing missing data, predicting network response, detecting anomalies and other tasks. Network generation, reconstruction, and prediction of its future topology are central issues of this field. In this project, we address the questions related to the understanding of the network modeling, investigating its structure and properties, and generating artificial networks. Most of the modern network generation methods are based either on various random graph models (reinforced by a set of properties such as power law distribution of node degrees, graph diameter, and number of triangles) or on the principle of replicating an existing model with elements of randomization such as R-MAT generator and Kronecker product modeling. Hierarchical models operate at different levels of network hierarchy but with the same finest elements of the network. However, in many cases the methods that include randomization and replication elements on the finest relationships between network nodes and modeling that addresses the problem of preserving a set of simplified properties do not fit accurately enough the real networks. Among the unsatisfactory features are numerically inadequate results, non-stability of algorithms on real (artificial) data, that have been tested on artificial (real) data, and incorrect behavior at different scales. One reason is that randomization and replication of existing structures can create conflicts between fine and coarse scales of the real network geometry. Moreover, the randomization and satisfying of some attribute at the same time can abolish those topological attributes that have been undefined or hidden from researchers. We propose to develop multilevel methods to model complex networks. The key point of the proposed strategy is that it will help to preserve part of the unknown structural attributes by guaranteeing the similar behavior of the real and artificial model on different scales.

99 GENERAL AND MISCELLANEOUS↗

Complex patterns of abnormal heartbeats

Individuals having frequent abnormal heartbeats interspersed with normal heartbeats may be at an increased risk of sudden cardiac death. However, mechanistic understanding of such cardiac arrhythmias is limited. We present a visual and qualitative method to display statistical properties of abnormal heartbeats. We introduce dynamical "heartprints" which reveal characteristic patterns in long clinical records encompassing approximately 10(5) heartbeats and may provide information about underlying mechanisms. We test if these dynamics can be reproduced by model simulations in which abnormal heartbeats are generated (i) randomly, (ii) at a fixed time interval following a preceding normal heartbeat, or (iii) by an independent oscillator that may or may not interact with the normal heartbeat. We compare the results of these three models and test their limitations to comprehensively simulate the statistical features of selected clinical records. This work introduces methods that can be used to test mathematical models of arrhythmogenesis and to develop a new understanding of underlying electrophysiologic mechanisms of cardiac arrhythmia.

Non-NASA Center↗

Statistical Analysis of Fading Power Vectors for Real-Time Atmospheric Channel Emulation

The design and testing of a free-space optical communication system requires assessment of the impact of random fluctuations in received power from a laser beam transmitted over an atmospheric channel. A number of methods for generating fading power vectors for in-lab emulation of an atmospheric channel have previously been reported. These techniques include spectral shaping and filtering of a signal from a normally distributed pseudo-random number generator, full wave optics simulations with random phase screens, and pre-recorded measurements from experimental free-space links. In this work, a statistical analysis of atmospheric fading is presented with the goal of producing a practical engineering model for the fading channel suitable for generating synthetic fade vectors in real-time for long-duration receiver testing with channel interleaving. Specifically, a parametric model is developed for turbulence-induced fade on space-to-ground links with large-aperture receivers, including aperture-averaging and the effects of aperture size on the instantaneous coupling efficiency for mode- limited receivers. In particular, we analyze the probability density function and temporal power spectrum for fluctuations of the coupling efficiency for few-mode fibers in a range of turbulence conditions.

free-space optical communication↗

Statistical Analysis of Fading Power Vectors for Real-Time Atmospheric Channel Emulation

The design and testing of a free-space optical communication system requires assessment of the impact of random fluctuations in received power from a laser beam transmitted over an atmospheric channel. A number of methods for generating fading power vectors for in-lab emulation of an atmospheric channel have previously been reported. These techniques include spectral shaping and filtering of a signal from a normally distributed pseudo-random number generator, full wave optics simulations with random phase screens, and pre-recorded measurements from experimental free-space links. In this work, a statistical analysis of atmospheric fading is presented with the goal of producing a practical engineering model for the fading channel suitable for generating synthetic fade vectors in real-time for long-duration receiver testing with channel interleaving. Specifically, a parametric model is developed for turbulence-induced fade on space-to-ground links with large-aperture receivers, including aperture-averaging and the effects of aperture size on the instantaneous coupling efficiency for mode-limited receivers. In particular, we analyze the probability density function and temporal power spectrum for fluctuations of the coupling efficiency for few-mode fibers in a range of turbulence conditions.

free-space optical communication↗

Testing Classical Properties from Quantum Data

Many properties of Boolean functions can be tested far more efficiently than the function itself can be learned. However, this dramatic advantage often disappears when testers are limited to random samples of ƒ instead of adaptively chosen queries to f. In this work we investigate the quantum version of this restriction: quantum algorithms that test properties of a Boolean function f solely from copies of either the function state |ƒ⟩ ∝ ∑ x |x, ƒ(x)⟩ or the phase state |(-1) ƒ ⟩ ∝ ∑ x (-1) ƒ(x) |x⟩. For monotonicity, symmetry, and triangle-freeness, we show passive quantum testers are unboundedly or super-polynomially better than their classical passive testing counterparts. They are competitive with classic query -based testers in each case. Our new testers use techniques beyond quantum Fourier sampling, and it turns out this is necessary: we show a certain class of bent functions can be tested from 𝒪(1) function states but has a sample complexity lower bound of 2 Ω(n) for any tester relying exclusively on Fourier and classical samples. Our passive quantum testers are competitive with classical query -based testers, but this isn't universal: we exhibit a testing problem that can be solved from 𝒪(1) classical queries but requires Ω(2 n/2 ) function state copies. The Forrelation problem provides a separation of the same magnitude in the opposite direction, so we conclude that quantum data and classical queries are "maximally incomparable" resources for testing. We also begin the study of lower bounds for testing from quantum data. For quantum monotonicity testing, we prove that the ensembles of [Goldreich et al., 2000; Black, 2024], which give exponential lower bounds for classical sample-based testing, do not yield any nontrivial lower bounds for testing from quantum data. New insights specific to quantum data will be required for proving copy complexity lower bounds for testing in this model.

Boolean Functions↗

The cumulative cost of additional wakefulness: dose-response effects on neurobehavioral functions and sleep physiology from chronic sleep restriction and total sleep deprivation

OBJECTIVES: To inform the debate over whether human sleep can be chronically reduced without consequences, we conducted a dose-response chronic sleep restriction experiment in which waking neurobehavioral and sleep physiological functions were monitored and compared to those for total sleep deprivation. DESIGN: The chronic sleep restriction experiment involved randomization to one of three sleep doses (4 h, 6 h, or 8 h time in bed per night), which were maintained for 14 consecutive days. The total sleep deprivation experiment involved 3 nights without sleep (0 h time in bed). Each study also involved 3 baseline (pre-deprivation) days and 3 recovery days. SETTING: Both experiments were conducted under standardized laboratory conditions with continuous behavioral, physiological and medical monitoring. PARTICIPANTS: A total of n = 48 healthy adults (ages 21-38) participated in the experiments. INTERVENTIONS: Noctumal sleep periods were restricted to 8 h, 6 h or 4 h per day for 14 days, or to 0 h for 3 days. All other sleep was prohibited. RESULTS: Chronic restriction of sleep periods to 4 h or 6 h per night over 14 consecutive days resulted in significant cumulative, dose-dependent deficits in cognitive performance on all tasks. Subjective sleepiness ratings showed an acute response to sleep restriction but only small further increases on subsequent days, and did not significantly differentiate the 6 h and 4 h conditions. Polysomnographic variables and delta power in the non-REM sleep EEG-a putative marker of sleep homeostasis--displayed an acute response to sleep restriction with negligible further changes across the 14 restricted nights. Comparison of chronic sleep restriction to total sleep deprivation showed that the latter resulted in disproportionately large waking neurobehavioral and sleep delta power responses relative to how much sleep was lost. A statistical model revealed that, regardless of the mode of sleep deprivation, lapses in behavioral alertness were near-linearly related to the cumulative duration of wakefulness in excess of 15.84 h (s.e. 0.73 h). CONCLUSIONS: Since chronic restriction of sleep to 6 h or less per night produced cognitive performance deficits equivalent to up to 2 nights of total sleep deprivation, it appears that even relatively moderate sleep restriction can seriously impair waking neurobehavioral functions in healthy adults. Sleepiness ratings suggest that subjects were largely unaware of these increasing cognitive deficits, which may explain why the impact of chronic sleep restriction on waking cognitive functions is often assumed to be benign. Physiological sleep responses to chronic restriction did not mirror waking neurobehavioral responses, but cumulative wakefulness in excess of a 15.84 h predicted performance lapses across all four experimental conditions. This suggests that sleep debt is perhaps best understood as resulting in additional wakefulness that has a neurobiological "cost" which accumulates over time.

NASA Discipline Regulatory Physiology↗