Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantitative analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Lithium-based transition-metal oxides for battery electrodes analyzed by x-ray photoelectron spectroscopy. I. LiNi 0.8 Co 0.15 0.05 O 2

X-ray photoelectron spectroscopy (XPS) was used to analyze fresh LiNi 0.8 Co 0.1 5Al 0.05 O 2 powder obtained from TODA America. XP spectra were obtained using incident monochromatic Al Kα radiation at 0.834 01 nm. A survey spectrum together with Ni 2p, Co 2p, Ni LMM, O 1s, C 1s, Al 2s, Ni 3s, Co 3s, Al 2p, Ni 3p, Co 3p, and Li 1s are presented. The spectra indicate the principal core level photoelectron and Auger electron signals and show carbon with only minor sulfur contamination. Making use of the O 1s, Al 2s, Ni 3p, Co 3p, Li 1s lines and neglecting the components related to surface contaminants, XPS quantitative analysis reveals an altered stoichiometry of the air-exposed powder surface of LiNi 0.2 Co 0.03 Al 0.1 O 0.7 .

25 ENERGY STORAGE↗

Lithium-based transition-metal oxides for battery electrodes analyzed by x-ray photoelectron spectroscopy. II. LiNi 0.8 Co 0.1 Mn 0.1 O 2

X-ray photoelectron spectroscopy (XPS) was used to analyze fresh LiNi 0.8 Co 0.1 Mn 0.1 O 2 powder obtained from Targray Technology International, Inc.. XP spectra were obtained using incident monochromatic Al Kα radiation at 0.834 01 nm. A survey spectrum together with Ni 2p, Co 2p, Mn 2p, Ni LMM, O 1s, C 1s, Al 2s, Ni 3s, Co 3s, Mn 3s, Ni 3p, Co 3p, Li 1s, and Mn 3p are presented. The spectra indicate the principal core level photoelectron and Auger electron signals and show only minor sulfur contamination. Making use of the O 1s, Ni 3p, Co 3p, Mn 3p, Li 1s lines and neglecting the components related to surface contaminants, XPS quantitative analysis reveals an altered stoichiometry of the air-exposed powder surface of LiNi 0.4 Co 0.02 Mn 0.1 O 0.8 .

25 ENERGY STORAGE↗

Lithium-based transition-metal oxides for battery electrodes analyzed by x-ray photoelectron spectroscopy. III. LiNi 0.6 Co 0.2 Mn 0.2 O 2

X-ray photoelectron spectroscopy (XPS) was used to analyze fresh LiNi 0.6 Co 0.2 Mn 0.2 O 2 powder obtained from Ecopro Company, Ltd.. XP spectra were obtained using incident monochromatic Al Kα radiation at 0.834 01 nm. A survey spectrum together with Ni 2p, Co 2p, Mn 2p, Ni LMM, O 1s, C 1s, Al 2s, Ni 3s, Co 3s, Mn 3s, Ni 3p, Co 3p, Li 1s, and Mn 3p are presented. The spectra indicate the principal core level photoelectron and Auger electron. Making use of the O 1s, Ni 3p, Co 3p, Mn 3p, Li 1s lines and neglecting the components related to surface contaminants, XPS quantitative analysis reveals an altered stoichiometry of the air-exposed powder surface of LiNi 0.2 Co 0.05 Mn 0.1 O 0.7 .

25 ENERGY STORAGE↗

Lithium-based transition-metal oxides for battery electrodes analyzed by x-ray photoelectron spectroscopy. IV. LiNi 0.5 Co 0.2 Mn 0.3 O 2

X-ray photoelectron spectroscopy (XPS) was used to analyze two lots of fresh LiNi 0.5 Co 0.2 Mn 0.3 O 2 powder and one of the two lot of LiNi0.5Co0.2Mn0.3O2 powder recalcined in air at 750 °C obtained from TODA America. XP spectra were obtained using incident monochromatic Al Kα radiation at 0.83401 nm. A survey spectrum together with Ni 2p, Co 2p, Mn 2p, Ni LMM, O 1s, C 1s, Al 2s, Ni 3s, Co 3s, Mn 3s, Ni 3p, Co 3p, Li 1s, and Mn 3p are presented. The spectra indicate the principal core level photoelectron and Auger electron signals and show only minor sulfur contamination. Making use of the O 1s, Ni 3p, Co 3p, Mn 3p, Li 1s lines and neglecting the components related to surface contaminants, XPS quantitative analysis reveals an altered stoichiometry of the air-exposed powder surfaces for the first lot, the first lot recalcined, and the second lot of LiNi0.3Co0.1Mn0.2O1.2, LiNi 0.4 Co 0.1 Mn 0.3 O 1.5 , and LiNi 0.4 Co 0.1 Mn 0.2 O 1.3 , respectively

25 ENERGY STORAGE↗

Lithium-based transition-metal oxides for battery electrodes analyzed by x-ray photoelectron spectroscopy. V. LiNi 0.4 Co 0.3 0.3 O 2

X-ray photoelectron spectroscopy (XPS) and x-ray-induced Auger electron spectroscopy were used to analyze untreated LiNi 0.4 Co 0.3 Mn 0.3 O 2 powder obtained from TODA America. X-ray photoelectron and x-ray-induced Auger electron spectra were obtained using incident monochromatic Al Kα radiation at 0.834 01 nm. A survey spectrum together with Ni 2p, Co 2p, Mn 2p, Ni LMM, O 1s, C 1s, Ni 3s, Co 3s, Mn 3s, Ni 3p, Co 3p, Li 1s, and Mn 3p are presented. The spectra indicate the principal core level photoelectron and Auger electron signals. Making use of the O 1s, Ni 3p, Co 3p, Mn 3p, and Li 1s lines and neglecting the components related to surface contaminants, XPS quantitative analysis reveals an altered stoichiometry of the air-exposed powder surface of LiN i0.4 Co 0.2 Mn 0.3 O 1.6 .

25 ENERGY STORAGE↗

Lithium-based transition-metal oxides for battery electrodes analyzed by x-ray photoelectron spectroscopy. VI. LiNi 0.4 Co 0.2 Mn 0.4 O 2

X-ray photoelectron spectroscopy (XPS) was used to analyze fresh LiNi 0.4 Co 0.2 Mn 0.4 O 2 powder obtained from TODA America. XP spectra were obtained using incident monochromatic Al Kα radiation at 0.834 01 nm. A survey spectrum together with Ni 2p, Co 2p, Mn 2p, Ni LMM, O 1s, C 1s, Al 2s, Ni 3s, Co 3s, Mn 3s, Ni 3p, Co 3p, Li 1s, and Mn 3p are presented. The spectra indicate the principal core level photoelectron and Auger electron. Making use of the O 1s, Ni 3p, Co 3p, Mn 3p, Li 1s lines and neglecting the components related to surface contaminants, XPS quantitative analysis reveals an altered stoichiometry of the air-exposed powder surface of LiNi 0.5 Co 0.2 Mn 0.5 O 1.9 .

25 ENERGY STORAGE↗

Lithium-based transition-metal oxides for battery electrodes analyzed by x-ray photoelectron spectroscopy. VII. LiNi 0.33 Co 0.33 Mn 0.33 O 2

X-ray photoelectron spectroscopy (XPS) was used to analyze fresh LiNi 0.33 Co 0.33 Mn 0.33 O 2 powder obtained from TODA America. XP spectra were obtained using incident monochromatic Al Kα radiation at 0.834 01 nm. A survey spectrum together with Ni 2p, Co 2p, Mn 2p, Ni LMM, O 1s, C 1s, Al 2s, Ni 3s, Co 3s, Mn 3s, Ni 3p, Co 3p, Li 1s, and Mn 3p are presented. The spectra indicate the principal core level photoelectron and Auger electron signals. Making use of the O 1s, Ni 3p, Co 3p, Mn 3p, Li 1s lines and neglecting the components related to surface contaminants, XPS quantitative analysis reveals an altered stoichiometry of the air-exposed powder surface of LiNi 0.4 Co 0.1 Mn 0.7 O 2.0 .

25 ENERGY STORAGE↗

Lithium-based transition-metal oxides for battery electrodes analyzed by x-ray photoelectron spectroscopy. VIII. Li 1.2 Ni 0.15 Co 0.1 Mn 0.55 O 2

X-ray photoelectron spectroscopy (XPS) and x-ray-induced Auger electron spectroscopy were used to analyze untreated Li 1.2 Ni 0.15 Co 0.1 Mn 0.55 O 2 powder obtained from TODA America. X-ray photoelectron and x-ray-induced Auger electron spectra were obtained using incident monochromatic Al Kα radiation at 0.83 01 nm. A survey spectrum together with Ni 2p, Co 2p, Mn 2p, Ni LMM, O 1s, C 1s, Ni 3s, Co 3s, Mn 3s, Ni 3p, Co 3p, Li 1s, and Mn 3p are presented. The spectra indicate the principal core level photoelectron and Auger electron signals. Making use of the O 1s, Ni 3p, Co 3p, Mn 3p, and Li 1s lines and neglecting the components related to surface contaminants, XPS quantitative analysis reveals an altered stoichiometry of the air-exposed powder surface of Li 1.2 Ni 0.4 Co 0.2 Mn 0.9 O 2.8 .

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lithium-based transition-metal oxides for battery electrodes analyzed by x-ray photoelectron spectroscopy. IX. LiCoO 2

X-ray photoelectron spectroscopy (XPS) and x-ray-induced Auger electron spectroscopy were used to analyze untreated LiCoO 2 powder obtained from BTR New Energy Materials, Inc. X-ray photoelectron and x-ray-induced Auger electron spectra were obtained using incident monochromatic Al Kα radiation at 0.834 01 nm. A survey spectrum together with Co 2p, O 1s, C 1s, Co 3s, Co 3p, and Li 1s are presented. The spectra indicate the principal core level photoelectron and Auger electron signals and show only minor tin contamination. Making use of the O 1s, Co 3p, and Li 1s lines and neglecting the components related to surface contaminants, XPS quantitative analysis reveals an altered stoichiometry of the air-exposed powder surface of LiCo 0.9 O 1.7 .

25 ENERGY STORAGE↗

Lithium-based transition-metal oxides for battery electrodes analyzed by x-ray photoelectron spectroscopy. X. Li 4 Ti 5 O 12

X-ray photoelectron spectroscopy (XPS) and x-ray-induced Auger electron spectroscopy were used to analyze untreated Li 4 Ti 5 O 12 powders obtained from Ishihara Sangyo Kaisha, Ltd. and Samsung Fine Chemicals Company, Ltd. X-ray photoelectron and x-ray-induced Auger electron spectra were obtained using incident monochromatic Al Kα radiation at 0.834 01 nm. A survey spectrum together with O 1s, Ti 2p, C 1s, Ti 3s, Li 1s, and Ti 3p are presented. The spectra indicate the principal core level photoelectron and Auger electron signals and show only minor potassium signal. Making use of the O 1s, Li 1s, and Ti 3p lines and neglecting the components related to surface contaminants, XPS quantitative analysis reveals an altered stoichiometry of the air-exposed powder surfaces from Ishihara Sangyo Kaisha, Ltd. and Samsung Fine Chemicals Company, Ltd. of Li 4 Ti 4.7 O 14.1 and Li 4 Ti 4.3 O 13.2 , respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray photoelectron spectroscopy data from lightly Pd doped TiO 2 anatase nanoparticles

Here, two sets of XPS spectra from ≈13 nm slightly Pd-doped anatase TiO 2 particles are reported. Anatase is the most stable form of TiO 2 for small particles, and these spectra are the first spectra from nano-sized anatase to appear in Surface Science Spectra. The high resolution Ti 2p spectrum has an extended range showing important loss features not appearing in most of the earlier data records. The O 1s spectrum also has loss features often ignored, and in this case, the loss features are overlapped by some of the Ti 2s peak features that complicate quantitative analysis. The spectra reported here were used as example spectra in a guide to backgrounds in XPS, and the availability of these spectra in digital form allows LRH-analysts to compare their background selections and analysis approach to those discussed in the guide.

36 MATERIALS SCIENCE↗

Poster — Thur Eve — 44: Linearization of Compartmental Models for More Robust Estimates of Regional Hemodynamic, Metabolic and Functional Parameters using DCE-CT/PET Imaging

Quantitative analysis of dynamic positron emission tomography (PET) data usually involves minimizing a cost function with nonlinear regression, wherein the choice of starting parameter values and the presence of local minima affect the bias and variability of the estimated kinetic parameters. These nonlinear methods can also require lengthy computation time, making them unsuitable for use in clinical settings. Kinetic modeling of PET aims to estimate the rate parameter k{sub 3}, which is the binding affinity of the tracer to a biological process of interest and is highly susceptible to noise inherent in PET image acquisition. We have developed linearized kinetic models for kinetic analysis of dynamic contrast enhanced computed tomography (DCE-CT)/PET imaging, including a 2-compartment model for DCE-CT and a 3-compartment model for PET. Use of kinetic parameters estimated from DCE-CT can stabilize the kinetic analysis of dynamic PET data, allowing for more robust estimation of k{sub 3}. Furthermore, these linearized models are solved with a non-negative least squares algorithm and together they provide other advantages including: 1) only one possible solution and they do not require a choice of starting parameter values, 2) parameter estimates are comparable in accuracy to those from nonlinear models, 3) significantly reduced computational time. Our simulated data show that when blood volume and permeability are estimated with DCE-CT, the bias of k{sub 3} estimation with our linearized model is 1.97 ± 38.5% for 1,000 runs with a signal-to-noise ratio of 10. In summary, we have developed a computationally efficient technique for accurate estimation of k{sub 3} from noisy dynamic PET data.

60 APPLIED LIFE SCIENCES↗

Super-resolution reconstruction for 4D computed tomography of the lung via the projections onto convex sets approach

Purpose: The use of 4D computed tomography (4D-CT) of the lung is important in lung cancer radiotherapy for tumor localization and treatment planning. Sometimes, dense sampling is not acquired along the superior–inferior direction. This disadvantage results in an interslice thickness that is much greater than in-plane voxel resolutions. Isotropic resolution is necessary for multiplanar display, but the commonly used interpolation operation blurs images. This paper presents a super-resolution (SR) reconstruction method to enhance 4D-CT resolution. Methods: The authors assume that the low-resolution images of different phases at the same position can be regarded as input “frames” to reconstruct high-resolution images. The SR technique is used to recover high-resolution images. Specifically, the Demons deformable registration algorithm is used to estimate the motion field between different “frames.” Then, the projection onto convex sets approach is implemented to reconstruct high-resolution lung images. Results: The performance of the SR algorithm is evaluated using both simulated and real datasets. Their method can generate clearer lung images and enhance image structure compared with cubic spline interpolation and back projection (BP) method. Quantitative analysis shows that the proposed algorithm decreases the root mean square error by 40.8% relative to cubic spline interpolation and 10.2% versus BP. Conclusions: A new algorithm has been developed to improve the resolution of 4D-CT. The algorithm outperforms the cubic spline interpolation and BP approaches by producing images with markedly improved structural clarity and greatly reduced artifacts.

60 APPLIED LIFE SCIENCES↗

Accelerated acquisition of tagged MRI for cardiac motion correction in simultaneous PET-MR: Phantom and patient studies

Purpose: Degradation of image quality caused by cardiac and respiratory motions hampers the diagnostic quality of cardiac PET. It has been shown that improved diagnostic accuracy of myocardial defect can be achieved by tagged MR (tMR) based PET motion correction using simultaneous PET-MR. However, one major hurdle for the adoption of tMR-based PET motion correction in the PET-MR routine is the long acquisition time needed for the collection of fully sampled tMR data. In this work, the authors propose an accelerated tMR acquisition strategy using parallel imaging and/or compressed sensing and assess the impact on the tMR-based motion corrected PET using phantom and patient data. Methods: Fully sampled tMR data were acquired simultaneously with PET list-mode data on two simultaneous PET-MR scanners for a cardiac phantom and a patient. Parallel imaging and compressed sensing were retrospectively performed by GRAPPA and kt-FOCUSS algorithms with various acceleration factors. Motion fields were estimated using nonrigid B-spline image registration from both the accelerated and fully sampled tMR images. The motion fields were incorporated into a motion corrected ordered subset expectation maximization reconstruction algorithm with motion-dependent attenuation correction. Results: Although tMR acceleration introduced image artifacts into the tMR images for both phantom and patient data, motion corrected PET images yielded similar image quality as those obtained using the fully sampled tMR images for low to moderate acceleration factors (<4). Quantitative analysis of myocardial defect contrast over ten independent noise realizations showed similar results. It was further observed that although the image quality of the motion corrected PET images deteriorates for high acceleration factors, the images were still superior to the images reconstructed without motion correction. Conclusions: Accelerated tMR images obtained with more than 4 times acceleration can still provide relatively accurate motion fields and yield tMR-based motion corrected PET images with similar image quality as those reconstructed using fully sampled tMR data. The reduction of tMR acquisition time makes it more compatible with routine clinical cardiac PET-MR studies.

60 APPLIED LIFE SCIENCES↗

IBEX: An open infrastructure software platform to facilitate collaborative work in radiomics

Purpose: Radiomics, which is the high-throughput extraction and analysis of quantitative image features, has been shown to have considerable potential to quantify the tumor phenotype. However, at present, a lack of software infrastructure has impeded the development of radiomics and its applications. Therefore, the authors developed the imaging biomarker explorer (IBEX), an open infrastructure software platform that flexibly supports common radiomics workflow tasks such as multimodality image data import and review, development of feature extraction algorithms, model validation, and consistent data sharing among multiple institutions. Methods: The IBEX software package was developed using the MATLAB and C/C++ programming languages. The software architecture deploys the modern model-view-controller, unit testing, and function handle programming concepts to isolate each quantitative imaging analysis task, to validate if their relevant data and algorithms are fit for use, and to plug in new modules. On one hand, IBEX is self-contained and ready to use: it has implemented common data importers, common image filters, and common feature extraction algorithms. On the other hand, IBEX provides an integrated development environment on top of MATLAB and C/C++, so users are not limited to its built-in functions. In the IBEX developer studio, users can plug in, debug, and test new algorithms, extending IBEX’s functionality. IBEX also supports quality assurance for data and feature algorithms: image data, regions of interest, and feature algorithm-related data can be reviewed, validated, and/or modified. More importantly, two key elements in collaborative workflows, the consistency of data sharing and the reproducibility of calculation result, are embedded in the IBEX workflow: image data, feature algorithms, and model validation including newly developed ones from different users can be easily and consistently shared so that results can be more easily reproduced between institutions. Results: Researchers with a variety of technical skill levels, including radiation oncologists, physicists, and computer scientists, have found the IBEX software to be intuitive, powerful, and easy to use. IBEX can be run at any computer with the windows operating system and 1GB RAM. The authors fully validated the implementation of all importers, preprocessing algorithms, and feature extraction algorithms. Windows version 1.0 beta of stand-alone IBEX and IBEX’s source code can be downloaded. Conclusions: The authors successfully implemented IBEX, an open infrastructure software platform that streamlines common radiomics workflow tasks. Its transparency, flexibility, and portability can greatly accelerate the pace of radiomics research and pave the way toward successful clinical translation.

60 APPLIED LIFE SCIENCES↗

SU-E-I-60: Quality Assurance Testing Methods and Customized Phantom for Magnetic Resonance Imaging and Spectroscopy

Purpose: The objectives of this study are to develop an magnetic resonance imaging and spectroscopy (MRI-MRS) fused phantom along with the inserts for metabolite quantification and to conduct quantitative analysis and evaluation of the layered vials of brain-mimicking solution for quality assurance (QA) performance, according to the localization sequence. Methods: The outer cylindrical phantom body is made of acrylic materials. The section other than where the inner vials are located was filled with copper sulfate and diluted with water so as to reduce the T1 relaxation time. Sodium chloride was included to provide conductivity similar to the human body. All measurements of MRI and MRS were made using a 3.0 T scanner (Achiva Tx 3.0 T; Philips Medical Systems, Netherlands). The MRI scan parameters were as follows: (1) spin echo (SE) T1-weighted image: repetition time (TR), 500ms; echo time (TE), 20ms; matrix, 256×256; field of view (FOV), 250mm; gap, 1mm; number of signal averages (NSA), 1; (2) SE T2-weighted image: TR, 2,500 ms; TE, 80 ms; matrix, 256×256; FOV, 250mm; gap, 1mm; NSA, 1; 23 slice images were obtained with slice thickness of 5mm. The water signal of each volume of interest was suppressed by variable pulse power and optimized relaxation delays (VAPOR) applied before the scan. By applying a point-resolved spectroscopy sequence, the MRS scan parameters were as follows: voxel size, 0.8×0.8×0.8 cm{sup 3}; TR, 2,000ms; TE, 35ms; NSA, 128. Results: Using the fused phantom, the results of measuring MRI factors were: geometric distortion, <2% and ±2 mm; image intensity uniformity, 83.09±1.33%; percent-signal ghosting, 0.025±0.004; low-contrast object detectability, 27.85±0.80. In addition, the signal-to-noise ratio of N-acetyl-aspartate was consistently high (42.00±5.66). Conclusion: The MRI-MRS QA factors obtained simultaneously using the phantom can facilitate evaluation of both images and spectra, and provide guidelines for obtaining MRI and MRS QA factors simultaneously. This study was supported by grant (2012-007883 and 2014R1A2A1A10050270) from the Mid-career Researcher Program through the NRF funded by Ministry of Science. In addition, this study was supported by the Industrial R&D of MOTIE/KEIT (10048997, Development of the core technology for integrated therapy devices based on real-time MRI-guided tumor tracking)

60 APPLIED LIFE SCIENCES↗

SU-E-T-213: Comparison of Treatment Efficiency of Gamma Knife SRS Plans for Brain Metastases with Different Planning Methods

Purpose: To improve Gamma Knife SRS treatment efficiency for brain metastases and compare the differences of treatment time and radiobiological effects between two different planning methods of automatic filling and manual placement of shots with inverse planning. Methods: T1-weighted MRI images with gadolinium contrast from five patients with a single brain metastatic-lesion were used in this retrospective study. Among them, two were from primary breast cancer, two from primary melanoma cancer and one from primary prostate cancer. For each patient, two plans were generated in Leksell GammaPlan10.1.1 for radiosurgical treatment with a Leksell GammaKnife Perfexion machine: one with automatic filling, automatic sector configuration and inverse optimization (Method1); and the other with manual placement of shots, manual setup of collimator sizes, manual setup of sector blocking and inverse optimization (Method2). Dosimetric quality of the plans was evaluated with parameters of Coverage, Selectivity, Gradient-Index and DVH. Beam-on Time, Number-of-Shots and Tumor Control Probability(TCP) were compared for the two plans while keeping their dosimetric quality very similar. Relative reduction of Beam-on Time and Number-of-Shots were calculated as the ratios among the two plans and used for quantitative analysis. Results: With very similar dosimetric and radiobiological plan quality, plans created with Method 2 had significantly reduced treatment time. Relative reduction of Beam-on Time ranged from 20% to 51 % (median:29%,p=0.001), and reduction of Number-of-Shots ranged from 5% to 67% (median:40%,p=0.0002), respectively. Time of plan creation for Method1 and Method2 was similar, approximately 20 minutes, excluding the time for tumor delineation. TCP calculated for the tumors from differential DVHs did not show significant difference between the two plans (p=0.35). Conclusion: The method of manual setup combined with inverse optimization in LGP for treatment of brain metastatic lesions with the Perfexion can achieve significantly higher time efficiency without degrading treatment quality.

60 APPLIED LIFE SCIENCES↗

Clinical introduction of image lag correction for a cone beam CT system

Purpose: Image lag in the flat-panel detector used for Linac integrated cone beam computed tomography (CBCT) has a degrading effect on CBCT image quality. The most prominent visible artifact is the presence of bright semicircular structure in the transverse view of the scans, known also as radar artifact. Several correction strategies have been proposed, but until now the clinical introduction of such corrections remains unreported. In November 2013, the authors have clinically implemented a previously proposed image lag correction on all of their machines at their main site in Amsterdam. The purpose of this study was to retrospectively evaluate the effect of the correction on the quality of CBCT images and evaluate the required calibration frequency. Methods: Image lag was measured in five clinical CBCT systems (Elekta Synergy 4.6) using an in-house developed beam interrupting device that stops the x-ray beam midway through the data acquisition of an unattenuated beam for calibration. A triple exponential falling edge response was fitted to the measured data and used to correct image lag from projection images with an infinite response. This filter, including an extrapolation for saturated pixels, was incorporated in the authors’ in-house developed clinical CBCT reconstruction software. To investigate the short-term stability of the lag and associated parameters, a series of five image lag measurement over a period of three months was performed. For quantitative analysis, the authors have retrospectively selected ten patients treated in the pelvic region. The apparent contrast was quantified in polar coordinates for scans reconstructed using the parameters obtained from different dates with and without saturation handling. Results: Visually, the radar artifact was minimal in scans reconstructed using image lag correction especially when saturation handling was used. In patient imaging, there was a significant reduction of the apparent contrast from 43 ± 16.7 to 15.5 ± 11.9 HU without the saturation handling and to 9.6 ± 12.1 HU with the saturation handling, depending on the date of the calibration. The image lag correction parameters were stable over a period of 3 months. The computational load was increased by approximately 10%, not endangering the fast in-line reconstruction. Conclusions: The lag correction was successfully implemented clinically and removed most image lag artifacts thus improving the image quality. Image lag correction parameters were stable for 3 months indicating low frequency of calibration requirements.

61 RADIATION PROTECTION AND DOSIMETRY↗