Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pump systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Advanced Compressors for CO2-Based Power Cycles and Energy

Pumped thermal energy storage (PTES) is a cost-effective method for grid-scale, long-duration electrical energy storage (LDES). PTES uses a heat pump cycle to transfer thermal energy from a low temperature reservoir (LTR) to a high temperature reservoir (HTR), later using a heat engine cycle to reverse the process. A key component of the PTES system, the heat pump compressor, represents a significant driver to the cost, performance and operating characteristics of the PTES system. For grid-scale charging (>100 MW), traditional compressor scaling charts indicate that the operating conditions needed would be best served by a multistage axial compressor. While frame gas turbine compressors at these power ratings exist and operate at higher pressure ratios than needed for the CO2 PTES system, the inlet pressure and fluid density of this application exceed experience values. A conceptual design of a large-scale CO2 axial compressor was completed, including mean-line estimates of the compressor performance at full power conditions. The results of the conceptual design were used to refine the PTES cycle design, and updated operating conditions provided for further aero design optimization. A roughly one third scale of the first three stages of the 100 MW compressor was designed, built, and tested at relevant PTES charging conditions. Results of this test program are compared against high-resolution computational fluid dynamics models.

Compressor Heat↗

Liquid Hydrogen Pumping For Hydrogen Targets

Forced circulation of liquid hydrogen through hydrogen targets is necessary when the geometry and heat load exceed the capacity of normal convection systems. Three small pumps, one centrifugal and two positive displacement, were built for that purpose. Hydrogen flows of one-half to two liters/min were attained while the pressure head developed was 10 to 40 ft of liquid hydrogen.

42 ENGINEERING↗

Development of mid-infrared solid state lasers for spaceborne lidar

This semiannual progress report covers work performed during the period from April 13, 1988 to October 13, 1988 under NASA grant number NAG-1-877 entitled, Development of mid-infrared solid state lasers for spaceborne lidar. We have designed a flashlamp-pumped Cr3(+);GSAG laser of pulsed laser energy greater than 200 mJ and of pulse width of 1 ms FWHM to simulate a high-power laser diode in pumping mid-infrared laser crystals such as Tm3(+), Er3(+), and/or Ho3(+)-ion doped YAG, YLF or other host materials. This Cr3(+);GSAG laser will be used to determine optimum conditions for laser diode pumped mid-infrared lasers, maximum energy extraction limit with longitudinal pumping, thermal damage limit, and other problems related to high power laser diode pumping. We have completed a modification of an existing flashlamp-pumped and liquid nitrogen cooled rare earth laser system for 60 J electrical input energy and a 500 micron pulse width, and have carried out preliminary experiments with a Ho(+):Er3(+):Tm3(+):YAG crystal to test the system performance. This flashlamp-pumped rare earth laser system will be used to determine optimum Tm3(+)-ion concentration in Ho3(+):Cr3(+):Tm3(+):YAG crystal in the remaining research period.

Whitney, Donald A.↗

Gain measurements of the Ca-Xe charge exchange system

Charge-exchange-pumped Ca(+) was studied for possible positive laser gain at 370.6 and 315.9 nm using an Xe MPD arc as the Xe(+) source. The present paper describes the MPD arc, the calcium injection system, the diagnostics for gain, and spontaneous emission measurements and results. No positive gain measurements were observed. A small Xe-Ca charge exchange cross section compared to He-metal laser systems charge exchange cross sections is the most probable reason why the result was negative.

Michels, C. J.↗

Component and System Level Research of Variable Capacity Heat Pumps

With high cooling and heating efficiencies, variable capacity heat pumps are an emerging technology with the potential to substantially reduce the energy required for the heating and cooling of residential structures. In order for them to make an impact in this area, they must first be more widely accepted by the American consumer as an alternative to less expensive single speed systems. This acceptance, in large part, is based upon a greater understanding of how these systems perform in real world tests. To this end, this study will evaluate the energy consumption and efficiencies of four variable capacity heat pumps installed in two unoccupied research homes in Farragut, a suburb of Knoxville, Tennessee, one occupied home in downtown Knoxville, and one occupied home in Duluth, Georgia.

Munk, Jeffrey D.↗

The ParFlow Sandtank: An interactive educational tool making invisible groundwater visible

Physical aquifer models are a highly effective teaching tool for hydrology education, however they come with inherent limitations that include the high cost to purchase, the static configuration of the model materials, the time required to visualize hydrogeological phenomena, and the effort to reset and clean them over time. To address these and other limitations, we have developed an interactive computer simulation of a physical aquifer model called the ParFlow Sandtank. In this gamified interface, users run the simulation using a familiar web-app like interface with sliders and buttons while learning real hydrologic concepts. Our user interface allows participants to dive into the world of hydrology, understanding assumptions about model parameters such as hydraulic conductivity, making decisions about inputs to groundwater aquifer systems such as pumping rates, visualizing outputs such as stream flow, transport, and saturation, and exploring various factors that impact real environmental systems such as climate change. The ParFlow Sandtank has already been used in a variety of educational settings with more than 9,000 users per year, and we feel this emerging educational tool can be used broadly in educational environments and can be scaled-up to provide greater accessibility for students and educators. Here we present the capabilities and workflow of the ParFlow Sandtank, two use cases, and additional tools and custom templates that have been developed to support and enhance the reach of the ParFlow Sandtank.

54 ENVIRONMENTAL SCIENCES↗

Dial Measurements of Free-Tropospheric Ozone Profiles in Huntsville, AL

A tropospheric ozone DIfferential Absorption Lidar (DIAL) system has been developed jointly by NASA and the University of Alabama at Huntsville (UAH). Two separated Nd:YAG pumped dye laser systems produce the laser pulses with wavelengths of 285 and 291 nm at 20 Hz frequency. The receiver is a Newtonian telescope with a 40 cm primary and a two-channel aft optics unit. The detection system currently uses photon counting to facilitate operations at the maximum achievable altitude. This lidar measures free-tropospheric ozone profiles between 4-10 km at Regional Atmospheric Profiling Laboratory for Discovery (RAPCD) in UAH campus (ASL 206 m) under both daytime and nighttime conditions. Frequent coincident ozonesonde flights and theoretical calculations provide evidence to indicate the retrieval accuracy ranges from approx.5% at 4 km to approx.60% at 10 km with 750-m vertical resolution and 30-minute integration. Three Hamamatsu 7400 PMTs and analog detection technique will be added on the current system to extend the measurement to approx.100 m above ground to monitor the PBL and lower tropospheric ozone variations.

Newchurch, Mike↗

Design and performance of heart assist or artificial heart control systems

The factors leading to the design of a controlled driving system for either a heart assist pump or artificial heart are discussed. The system provides square pressure waveform to drive a pneumatic-type blood pump. For assist usage the system uses an R-wave detector circuit that can detect the R-wave of the electrocardiogram in the presence of electrical disturbances. This circuit provides a signal useful for synchronizing an assist pump with the natural heart. It synchronizes a square wave circuit, the output of which is converted into square waveforms of pneumatic pressure suitable for driving both assist device and artificial heart. The pressure levels of the driving waveforms are controlled by means of feedback channels to maintain physiological regulation of the artificial heart's output flow. A more compact system that could achieve similar regulatory characteristics is also discussed.

Webb, J. A., Jr.↗

Perform Life Cycle Energy and GHG Emission Analysis, Select Candidate Refrigerant(s), Developing Heat Pump by Using Low-GWP Refrigerants and 5 mm Diameter Tubes

Reducing environmental impacts from the energy conversion systems has been an important research topic due to recent severe global climate changes. In residential buildings, the space heating and cooling are main energy consumers, which are relying on vapor compression based heat pumps. To mitigate the environmental impacts of residential systems, the heat pumps using low-GWP refrigerants and 5mm-tube heat exchangers are proposed to replace the conventional 9 mm or 7 mm tube heat exchangers. This research uses a simulation-based design method to optimize the refrigerant circuitries of a 5-ton low-GWP refrigerant heat pumps whose indoor and outdoor heat exchangers adopt 5 mm tubes. Heat pump systems using four commercially available low-GWP refrigerants (R454A, R454C, ARM20A and ARM20B) are optimized and compared with the baseline R410A system. The results indicate that directly replacing 9 mm tubes into 5mm tubes in the baseline systems induces heat pump performance degradation; by optimizing the 5 mm tube heat pumps with added tube rows, the system refrigerant charge is reduced up to 33% compared with the baseline; the optimized low-GWP 5 mm tube heat pumps offer the same or higher performance under both cooling and heating mode; that under cooling mode, the EER improvement is up to 10.7% and under heating mode the COP improvement is up to 3.4%; and a smart flow control device to maintain counter-flow circuitry pattern on both operating modes can improve the heating performance of 5 mm tube optimized system by up to 3.0%. In an effort to better understand the environmental impacts of these systems, life cycle climate performance (LCCP) evaluation method is used to assess the baseline and optimized systems. LCCP considers the direct and indirect emissions of the system over the course of its lifetime from manufacturing to disposal. Our analyses indicate that the optimized systems using 5mm tubes and low-GWP refrigerants can reduce life-cycle CO 2 emission significantly. And improving system efficiency is the most effective way to reduce the emission of low-GWP refrigerant systems. This report shows that using 5 mm diameter tubes in heat exchangers is a feasible approach to develop heat pumps with low-GWP refrigerants. Using the proposed design approach can yield higher system efficiency with lower environmental impact.

42 ENGINEERING↗

Theory of tunneling between two-dimensional electron layers driven by spin pumping: Adiabatic regime and beyond

Tunneling spectroscopy between parallel two-dimensional (2D) electronic systems provides a powerful method to probe the underlying electronic properties by measuring tunneling conductance. Here, in this work, we present a theoretical framework for spin transport in 2D-to-2D tunneling systems, driven by spin pumping. This theory applies to a vertical heterostructure where two layers of metallic 2D electron systems are separated by an insulating barrier, with one layer exchange coupled to a magnetic layer driven at resonance. Utilizing a nonperturbative Floquet-Keldysh formalism, we derive general expressions for the tunneling spin and charge currents across a broad range of driving frequencies, extending beyond the traditional adiabatic pumping regime. At low frequencies, we obtain analytical results that recover the known behaviors in the adiabatic regime. However, at higher frequencies, our numerical findings reveal significant deviations in the dependence of spin and charge currents on both frequency and precession angle. This work offers fresh insights into the role of magnetization dynamics in tunneling transport, opening up new avenues for exploring nonadiabatic spin pumping phenomena.

Green's function methods↗

Development of HPWH System Model, Using All Microchannel Heat Exchangers

In this report, 24-hour energy factor (EF) and first-hour draw rating (FHR) simulations were conducted on two heat pump water heater systems (HPWHs), one using a fin-and-tube evaporator and wrapped-tank condenser coil with D-shape tubes, and the other using a micro-channel evaporator and wrapped-tank condenser coil with microchannel tubes. Alternative refrigerants as drop-in replacements of R-134a were evaluated, including R-1234yf, R-1234ze(E), propane (R-290), R-450A and R-513A. The results are summarized below: 1.Microchannel heat exchangers can decrease the system charge down to 30% relative to fin-and-tube evaporator and wrapped-tank D tubes.2.Having the same contact surface area to the water tank and evaporator frontal flow area, the system using microchannel heat exchangers (MHXs) results in 5% efficiency degradation. Due to the very small cross-sectional flow area of a microchannel tube, MHXs tend to have multiple parallel tubes to restrict the refrigerant pressure drop. The parallel pattern can’t utilize the water temperature stratification as effectively as the D-shape tubes, which are arranged in one or two circuits and counter flow to the water stratification. 3.Refrigerant drop-in system simulations were conducted for R-1234yf, R-1234ze(E), propane, R450A and R513A in comparison to R-134a. Among the alternatives, propane has the largest volumetric capacity, which results in shortest HPWH run time and highest first-hour rating. Propane leads to the smallest energy factor because its largest volumetric capacity overloads the heat exchangers. R-1234ze(E) has the smallest volumetric capacity, highest energy factor, but smallest first-hour rating. R-1234yf, R-450A and R-513A achieve similar performance indices as R-134a. 4.Propane requires the least refrigerant mass (45% relative to R-134a). If a wrapped-tank microchannel condenser and microchannel evaporator are used, the required system charge can be limited below 150 grams, which makes it feasible to use propane for domestic HPWH.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Consumer Guide to Residential Renewable Energy

Learn how installing residential renewable energy systems, such as geothermal heat pumps and wind or solar energy systems, can save energy, lower utility bills, and earn homeowners money. This fact sheet from Energy Saver includes information on how to start planning to install renewable energy systems at home.

residential renewable energy, geothermal heat pump↗

From Concept-to-Flight: An Active Active Fluid Loop Based Thermal Control System for Mars Science Laboratory Rover

The Mars Science Laboratory (MSL) rover, Curiosity, which was launched on November 26, 2011, incorporates a novel active thermal control system to keep the sensitive electronics and science instruments at safe operating and survival temperatures. While the diurnal temperature variations on the Mars surface range from -120 C to +30 C, the sensitive equipment are kept within -40 C to +50 C. The active thermal control system is based on a single-phase mechanically pumped fluid loop (MPFL) system which removes or recovers excess waste heat and manages it to maintain the sensitive equipment inside the rover at safe temperatures. This paper will describe the entire process of developing this active thermal control system for the MSL rover from concept to flight implementation. The development of the rover thermal control system during its architecture, design, fabrication, integration, testing, and launch is described.

heat rejection systems↗

Nonlinear effects of inertial Alfvén wave in low beta plasmas

This paper is devoted to the study of the nonlinear interaction and propagation of high frequency pump inertial Alfvén wave (IAW) with comparatively low frequency IAW with emphasis on nonlinear effects and applications within space plasma and astrophysics for low β-plasma (β≪m{sub e}/m{sub i}). We have developed a set of dimensionless equations in the presence of ponderomotive nonlinearity due to high frequency pump IAW in the dynamics of comparatively low frequency IAW. Stability analysis and numerical simulation have been carried out for the coupled system comprising of pump IAW and low frequency IAW to study the localization and turbulent spectra, applicable to auroral region. The result reveals that localized structures become more complex and intense in nature at the quasi steady state. From the obtained result, we found that the present model may be useful to study the turbulent fluctuations in accordance with the observations of FAST/THEMIS spacecraft.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of SCALE to Molten Salt Fueled Reactor Physics in Support of Severe Accident Analyses

As part of a US Nuclear Regulatory Commission–sponsored project to assess the modeling and simulation capabilities for accident progression, source term, and consequence analysis for advanced reactor technologies with SCALE and MELCOR, SCALE was used for the modeling and simulation of a molten salt-fueled reactor (MSR). SCALE capabilities for the modeling of MSR physics were demonstrated based on the Molten Salt Reactor Experiment (MSRE). Of primary interest were the determination of the system’s nuclide inventory, as well as the inventories in the various regions of the loop, considering that the fuel is continuously pumped through the system. This report contains discussions on the following: 1. Determination of the system-average fuel salt inventory considering fission gas removal in the off-gas system and noble metal removal through plating out at the heat exchanger using recent enhancements in SCALE’s depletion sequence TRITON, 2. Assessment of the nuclide spatial distribution throughout the loop using SCALE’s depletion solver ORIGEN, 3. Calculation of the core’s power profile, flux profile, temperature reactivity coefficients, and xenon reactivity using full-core calculations with SCALE’s Monte Carlo code KENO-VI. The results obtained with SCALE were post-processed to provide the MELCOR team with the core inventory and decay heat of the system, as well as the inventory and decay heat of individual regions in the loop, a zone-wise power profile, temperature feedback coefficients, and the xenon worth.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of the sonic pump levitation

A prototype levitating/positioning device termed the Sonic Pump Levitator was designed, built and successfully tested in full gravity and in the reduced gravity of the parabolic flight regime of the KC-135. Positioning is achieved by timely and appropriate application of gas momentum from one or more of six sonic pumps. The sonic pumps, which are arranged orthogonally in opposed pairs about the levitation region, are activated by an electro-optical, computer controlled, feedback system. The sonic pump is a transducer which is capable of converting sound energy into a directed flow of gas. It consists of a loudspeaker whose face is sealed by a closure perforated by one or more orifices. The diaphragm of the loudspeaker is the only moving part of the sonic pump, no valves being needed. This very low inertia electromechanical device was developed to provide the short response time necessary to keep pace with the demands of computerized position keeping.

Dunn, S. A.↗

Levitating Furnance for Containerless Processing in Space

The purpose of this project is to design, construct and test a levitator which would function reliably in a radiant heated cold wall furnace in a reduced gravity environment. A prototype levitating/positioning device termed the Sonic Pump Levitator is designed, built and successfully tested in full gravity and in the reduced gravity of the parabolic flight regime of the KC-135. Positioning is achieved by timely and appropriate application of gas momentum from one or more of six sonic pumps. The sonic pumps, which are arranged orthogonally in opposed pairs about the levitation region, are activated by an electro-optical, computer controlled, feedback system. The Sonic Pump Levitator is a promising candidate for containerless processing in microgravity. Being a null point device, it imposes minimal perturbation on the levitated, or positioned, target. Functioning as it does by optical feedback controlled jets of air, it would be expected to be free from disturbance caused by high temperature. This expectation is now being examined experimentally.

Dunn, S. A.↗