Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “positron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Predicting amyloid status in corticobasal syndrome using modified clinical criteria, magnetic resonance imaging and fluorodeoxyglucose positron emission tomography

Introduction Group comparisons demonstrate greater visuospatial and memory deficits and temporoparietal-predominant degeneration on neuroimaging in patients with corticobasal syndrome (CBS) found to have Alzheimer’s disease (AD) pathology versus those with underlying frontotemporal lobar degeneration (FTLD). The value of these features in predicting underlying AD pathology in individual patients is unknown. The goal of this study is to evaluate the utility of modified clinical criteria and visual interpretations of magnetic resonance imaging (MRI) and fluorodeoxyglucose positron emission tomography (FDG-PET) for predicting amyloid deposition (as a surrogate of Alzheimer’s disease neuropathology) in patients presenting with CBS. Methods In total, 25 patients meeting CBS core criteria underwent amyloid (Pittsburgh compound B; PIB) PET scans. Clinical records, MRI, and FDG scans were reviewed blinded to PIB results. Modified clinical criteria were used to classify CBS patients as temporoparietal variant CBS (tpvCBS) or frontal variant CBS (fvCBS). MRI and FDG-PET were classified based on the predominant atrophy/hypometabolism pattern (frontal or temporoparietal). Results A total of 9 out of 13 patients classified as tpvCBS were PIB+, compared to 2out of 12 patients classified as fvCBS ( P < 0.01, sensitivity 82%, specificity 71% for PIB+ status). Visual MRI reads had 73% sensitivity and 46% specificity for PIB+ status with moderate intra-rater reliability (Cohen’s kappa = 0.42). Visual FDG reads had higher sensitivity (91%) for PIB+ status with perfect intra-rater reliability (kappa = 1.00), though specificity was low (50%). PIB results were confirmed in all 8 patients with available histopathology (3 PIB+ with confirmed AD, 5 PIB- with FTLD). Conclusions Splitting CBS patients into frontal or temporoparietal clinical variants can help predict the likelihood of underlying AD, but criteria require further refinement. Temporoparietal-predominant neuroimaging patterns are sensitive but not specific for AD.

Neurosciences & Neurology↗

Reference tissue normalization in longitudinal 18F-florbetapir positron emission tomography of late mild cognitive impairment

Background: Semiquantitative methods such as the standardized uptake value ratio (SUVR) require normalization of the radiotracer activity to a reference tissue to monitor changes in the accumulation of amyloid-β (Aβ) plaques measured with positron emission tomography (PET). The objective of this study was to evaluate the effect of reference tissue normalization in a test–retest 18F-florbetapir SUVR study using cerebellar gray matter, white matter (two different segmentation masks), brainstem, and corpus callosum as reference regions. Methods: We calculated the correlation between 18F-florbetapir PET and concurrent cerebrospinal fluid (CSF) Aβ1–42 levels in a late mild cognitive impairment cohort with longitudinal PET and CSF data over the course of 2 years. In addition to conventional SUVR analysis using mean and median values of normalized brain radiotracer activity, we investigated a new image analysis technique—the weighted two-point correlation function (wS2)—to capture potentially more subtle changes in Aβ-PET data. Results: Compared with the SUVRs normalized to cerebellar gray matter, all cerebral-to-white matter normalization schemes resulted in a higher inverse correlation between PET and CSF Aβ1–42, while the brainstem normalization gave the best results (high and most stable correlation). Compared with the SUVR mean and median values, the wS2 values were associated with the lowest coefficient of variation and highest inverse correlation to CSF Aβ1–42 levels across all time points and reference regions, including the cerebellar gray matter. Conclusions: The selection of reference tissue for normalization and the choice of image analysis method can affect changes in cortical 18F-florbetapir uptake in longitudinal studies.

59 BASIC BIOLOGICAL SCIENCES↗

Accurate determination of production data of the non-standard positron emitter 86 Y via the 86 Sr(p,n)-reaction

In view of several significant discrepancies in the excitation function of the 86 Sr(p,n) 86g+xm Y reaction which is the method of choice for the production of the non-standard positron emitter 86 Y for theranostic application, we carried out a careful measurement of the cross sections of this reaction from its threshold up to 16.2 MeV at Forschungszentrum Jülich (FZJ) and from 14.3 to 24.5 MeV at LBNL. Thin samples of 96.4% enriched 86 SrCO 3 were prepared by sedimentation and, after irradiation with protons in a stacked-form, the induced radioactivity was measured by high-resolution γ -ray spectrometry. The projectile flux was determined by using the monitor reactions nat Cu(p,xn) 62,63,65 Zn and nat Ti(p,x) 48 V, and the calculated proton energy for each sample was verified by considering the ratios of two reaction products of different thresholds. Additionally, the experimental cross section data obtained agreed well with the results of a nuclear model calculation based on the code TALYS. From the cross section data, the integral yield of 86 Y was calculated. Over the optimum production energy range E p = 14 → 7 MeV the yield of 86 Y amounts to 291 MBq/μA for 1 h irradiation time. This value is appreciably lower than the previous literature values calculated from measured and evaluated excitation functions. It is, however, more compatible with the experimental yields of 86 Y obtained in clinical scale production runs. The levels of the isotopic impurities 87m Y, 87g Y, and 88 Y were also estimated and found to be <2% in sum.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Selected advances in the accelerator design of the Future Circular Electron-Positron Collider (FCC-ee)

In autumn 2023, the FCC Feasibility Study underwent a crucial “mid-term review”. We describe some accelerator performance risks for the proposed future circular electron-positron collider, FCC-ee, identified for, and during, the mid-term review. For the collider rings, these are the collective effects when running on the Z resonance – especially resistive wall, beam-beam, and electron cloud –, the beam lifetime, dynamic aperture, alignment tolerances, and beam-based alignment. For the booster, the primary concern is the vacuum system, with regard to impedance and effects of the residual gas. For the injector, the layout and the linac repetition rate are primary considerations. We discuss the various issues and report the planned mitigations.

43 PARTICLE ACCELERATORS↗

A Concept for Ultra-High Energy Electron and Positron Test Beams at Fermilab [PowerPoint]

Experimenters looking for energies higher than 30 GeV will have no current comparable alternatives when CERN test beams are shutdown for 2 years at the end of 2018. Alternate lab electron and positron test beam limits are DESY: Under 10 GeV/c, SLAC: Limited to 25 GeV/c; Fermilab: Ranged from 1 - 32 GeV (highest momenta of ~31.9986 GeV/c) and Mixed Species. A unique opportunity to attract a new group of users has presented itself. As CERN e ± test beams are mixed species, providing higher purity, ultra high energy beams has been requested.

43 PARTICLE ACCELERATORS↗

A High Intensity Spin-Polarized Electron Photogun to Drive a Polarized Positron Source

A photogun to generate a high-intensity, highly spin-polarized electron beam >90% with unprecedented charge lifetime in the kilocoulomb range is envisioned at JLab for a proposed Ce+BAF polarized positron beam source. The electron photogun is expected to provide a CW beam of >1 mA for a month without intervention. A limiting factor is ion-back bom-bardment on the strained-superlattice GaAs-photocathode which can be reduced by improving the photogun vacuum or biasing the anode. Additionally, increasing the laser spot size can help mitigate ion-induced damage. However, eventually the laser size becomes too large for the photogun electrode. An envisioned photogun design will incorporate larger electrodes to accommodate larger and off-center laser spot sizes. Compatible larger conical insulators which operate >300 kV for beam injection into a Beta~1 SRF booster are also necessary.

Hernandez Garcia, Carlos↗

Improvement of the technique of identification of electrons and positrons with use of electromagnetic calorimeter of the CLAS detector

We study the dependence of the sensitivity of response of the electromagnetic calorimeter of CLAS plant on the momenta of electrons and positrons. We made calculation of this dependence and elaborated a method for its employment in identification of e- and e+. We have shown that the new method of selection of e- and e+ improves the quality of identification by about 10%. We used the experimental data obtained with the plant CLAS of linear accelerator at Jefferson laboratory (USA).

43 PARTICLE ACCELERATORS↗

Identifying Redox Orbitals and Defects in Lithium-Ion Cathodes with Compton Scattering and Positron Annihilation Spectroscopies: A Review

Reduction-oxidation (redox) reactions that transfer conduction electrons from the anode to the cathode are the fundamental processes responsible for generating power in Li-ion batteries. Electronic and microstructural features of the cathode material are controlled by the nature of the redox orbitals and how they respond to Li intercalation. Thus, redox orbitals play a key role in performance of the battery and its degradation with cycling. We unravel spectroscopic descriptors that can be used to gain an atomic-scale handle on the redox mechanisms underlying Li-ion batteries. Our focus is on X-ray Compton Scattering and Positron Annihilation spectroscopies and the related computational approaches for the purpose of identifying orbitals involved in electrochemical transformations in the cathode. This review provides insight into the workings of lithium-ion batteries and opens a pathway for rational design of next-generation battery materials.

Nokelainen, Johannes (ORCID:0000000328857850)↗

Radioligands for Tropomyosin Receptor Kinase (Trk) Positron Emission Tomography Imaging

The tropomyosin receptor kinases family (TrkA, TrkB, and TrkC) supports neuronal growth, survival, and differentiation during development, adult life, and aging. TrkA/B/C downregulation is a prominent hallmark of various neurological disorders including Alzheimer’s disease (AD). Abnormally expressed or overexpressed full-length or oncogenic fusion TrkA/B/C proteins were shown to drive tumorigenesis in a variety of neurogenic and non-neurogenic human cancers and are currently the focus of intensive clinical research. Neurologic and oncologic studies of the spatiotemporal alterations in TrkA/B/C expression and density and the determination of target engagement of emerging antineoplastic clinical inhibitors in normal and diseased tissue are crucially needed but have remained largely unexplored due to the lack of suitable non-invasive probes. Here, we review the recent development of carbon-11- and fluorine-18-labeled positron emission tomography (PET) radioligands based on specifically designed small molecule kinase catalytic domain-binding inhibitors of TrkA/B/C. Basic developments in medicinal chemistry, radiolabeling and translational PET imaging in multiple species including humans are highlighted.

Schirrmacher, Ralf (ORCID:0000000270983036)↗

Relativistic Magnetic Reconnection in Electron–Positron–Proton Plasmas: Implications for Jets of Active Galactic Nuclei

Magnetic reconnection is often invoked to explain the nonthermal radiation of relativistic outflows, including jets of active galactic nuclei (AGNs). Motivated by the largely unknown plasma composition of AGN jets, we study reconnection in the unexplored regime of electron–positron–proton (pair-proton) plasmas with large-scale two-dimensional particle-in-cell simulations. We cover a wide range of pair multiplicities (lepton-to-proton number ratio κ = 1–199) for different values of the all-species plasma magnetization (σ = 1, 3, and 10) and electron temperature (${{\rm{\Theta }}}_{e}\equiv {{kT}}_{e}/{m}_{e}{c}^{2}=0.1\mbox{--}100$). We focus on the dependence of the post-reconnection energy partition and lepton energy spectra on the hot pair plasma magnetization ${\sigma }_{e,h}$ (i.e., the ratio of magnetic to pair enthalpy densities). We find that the post-reconnection energy is shared roughly equally between magnetic fields, pairs, and protons for ${\sigma }_{e,h}$ gsim 3. We empirically find that the mean lepton Lorentz factor in the post-reconnection region depends on σ, Θ e , and ${\sigma }_{e,h}$ as $\langle {\gamma }_{e}-1\rangle \approx \sqrt{\sigma }(1+4{{\rm{\Theta }}}_{e})\left(1+{\sigma }_{e,h}/30\right)$, for σ ≥ 1. The high-energy part of the post-reconnection lepton energy distributions can be described by a power law, whose slope is mainly controlled by ${\sigma }_{e,h}$ for κ gsim 3–6, with harder power laws obtained for higher magnetizations. We finally show that reconnection in pair-proton plasmas with multiplicities κ ~ 1–20, magnetizations σ ~ 1–10, and temperatures Θ e ~ 1–10 results in particle power-law slopes and average electron Lorentz factors that are consistent with those inferred in leptonic models of AGN jet emission.

79 ASTRONOMY AND ASTROPHYSICS↗