Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “peak flows”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Simulation of 1% hot leg SBLOCA with TRACE5

During a Small Break Loss-of-Coolant Accident (SBLOCA) transient, depressurization can be slow enough to delay the Accumulators (ACC) entry for a long time. Actuation of High Pressure Injection (HPI) system is then necessary in order to maintain the core temperature low enough to avoid core boil off, and consequently avoiding the core level to fall below fuel rods level, thus producing a temperature trip in the fuel cladding. In this frame, the OECD/NEA ROSA Project Test 1.2 (SB-HL-17 in Japan Atomic Energy Agency (JAEA)) has been simulated using the thermal-hydraulic code TRACES. Test 1.2 was performed in the Large Scale Test Facility (LSTF) reproducing a 1% hot leg SBLOCA in a Pressurized Water Reactor (PWR). A comparison between experimental and the main simulated variables was performed to study the effect of important parameters (liquid stratification, geometry and size) to model the break. Finally, in an Emergency Core Cooling System (ECCS) failure scenario, loss of coolant is large enough to produce core boil-off and a Peak Cladding Temperature (PCT) excursion. With this purpose a sensitivity analysis varying the HPI mass flow rate has been performed covering the range between HPI actuation and failure. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ACCRETION ONTO INTERMEDIATE-MASS BLACK HOLES REGULATED BY RADIATIVE FEEDBACK. I. PARAMETRIC STUDY FOR SPHERICALLY SYMMETRIC ACCRETION

We study the effect of radiative feedback on accretion onto intermediate-mass black holes (IMBHs) using the hydrodynamical code ZEUS-MP with a radiative transfer algorithm. In this paper, the first of a series, we assume accretion from a uniformly dense gas with zero angular momentum and extremely low metallicity. Our one-dimensional (1D) and 2D simulations explore how X-ray and UV radiation emitted near the black hole regulates the gas supply from large scales. Both 1D and 2D simulations show similar accretion rates and periods between peaks in accretion, meaning that the hydro-instabilities that develop in 2D simulations do not affect the mean flow properties. We present a suite of simulations exploring accretion across a large parameter space, including different radiative efficiencies and radiation spectra, black hole masses, density, and temperature, T{sub {infinity}}, of the neighboring gas. In agreement with previous studies, we find regular oscillatory behavior of the accretion rate, with duty cycle {approx}6%, mean accretion rate 3% (T{sub {infinity}}/10{sup 4} K){sup 2.5} of the Bondi rate and peak accretion {approx}10 times the mean for T{sub {infinity}} ranging between 3000 K and 15, 000 K. We derive parametric formulae for the period between bursts, the mean accretion rate, and the peak luminosity of the bursts and thus provide a formulation of how feedback-regulated accretion operates. The temperature profile of the hot ionized gas is crucial in determining the accretion rate, while the period of the bursts is proportional to the mean size of the Stroemgren sphere, and we find qualitatively different modes of accretion in the high versus low density regimes. We also find that a softer radiation spectrum produces a higher mean accretion rate. However, it is still unclear what the effect of a significant time delay is between the accretion rate at our inner boundary and the output luminosity. Such a delay is expected in realistic cases with non-zero angular momentum and may affect the time-dependent phenomenology presented here. This study is a first step to model the growth of seed black holes in the early universe and to make a prediction of the number and the luminosity of ultraluminous X-ray sources in galaxies produced by IMBHs accreting from the interstellar medium.

79 ASTRONOMY AND ASTROPHYSICS↗

SHORT TIMESCALE VARIATIONS OF THE H{alpha} DOUBLE-PEAKED PROFILE OF THE NUCLEUS OF NGC 1097

The broad (FWHM {approx} 10,000 km s{sup -1}) double-peaked H{alpha} profile from the LINER/Seyfert 1 nucleus of NGC 1097 was discovered in 1991 and monitored for the following 11 years. The profile showed variations attributed to the rotation of gas in a non-axisymmetric Keplerian accretion disk, ionized by a varying radiatively inefficient accretion flow (RIAF) located in the inner parts of the disk. We present and model 11 new spectroscopic observations of the double-peaked profile taken between 2010 March and 2011 March. This series of observations was motivated by the finding that in 2010 March the flux in the double-peaked line was again strong, indeed, in 2010 December, even stronger than in the observations of a decade ago. We also discovered shorter timescale variations than in the previous observations: (1) the first, of {approx}7 days, is interpreted as due to 'reverberation' of the variation of the ionizing source luminosity, and the timescale of 7 days as the light crossing time between the source and the accretion disk; this new timescale and its interpretation provides a distance between the emitting gas and the supermassive black hole and as such introduces a new constraint on its mass; (2) the second, of Almost-Equal-To 5 months, was attributed to the rotation of a spiral arm in the disk, which was found to occur on the dynamical timescale. We use two accretion disk models to fit theoretical profiles to the new data, both having non-axisymmetric emissivities produced by the presence of an one-armed spiral. Our modeling constrains the rotation period for the spiral to be Almost-Equal-To 18 months. This work supports our previous conclusion that the broad double-peaked Balmer emission lines in NGC 1097-and probably also in other low-luminosity active nuclei-originate from an accretion disk ionized by a central RIAF.

79 ASTRONOMY AND ASTROPHYSICS↗

Instability Wave–Streak Interactions in a High Mach Number Boundary Layer at Flight Conditions

The interaction of stationary streaks undergoing nonmodal growth with modally unstable instability waves in a hypersonic boundary-layer flow is studied using numerical computations. The geometry and flow conditions are selected to match a relevant trajectory location from the ascent phase of the HIFiRE-1 flight experiment; namely, a 7 degree half-angle, circular cone with 2.5 mm nose radius, freestream Mach number equal to 5.30, unit Reynolds number equal to 13.42 m -1 , and wall-to-adiabatic temperature ratio of approximately 0.35 over most of the vehicle. This paper investigates the nonlinear evolution of initially linear optimal disturbances that evolve into finite-amplitude streaks, followed by an analysis of the modal instability characteristics of the perturbed, streaky boundary-layer flow. The investigation is performed with stationary direct numerical simulations (DNS) and plane-marching parabolized stability equations (PSE), in conjunction with partial-differential-equation-based planar eigenvalue analysis. The overall effect of streaks is to reduce the peak amplification factors of instability waves, indicating a possible downstream shift in the onset of laminar-turbulent transition. The present study confirms previous findings that the mean flow distortion of the nonlinear streak perturbation reduces the amplification rates of the Mack-mode instability. More importantly, however, the present results demonstrate that the spanwise varying component of the streak can produce a larger effect on the Mack-mode amplification. The study with selected azimuthal wavenumbers for the stationary streaks reveals that a wavenumber of approximately 1.4 times larger than the optimal wavenumber is more effective in stabilizing the planar Mack-mode instabilities. In the absence of unstable first-mode waves for the present cold-wall condition, transition onset is expected to be delayed until the peak streak amplitude increases to nearly 35 percent of the freestream velocity, when intrinsic instabilities of the boundary-layer streaks begin to dominate the transition process. For streak amplitudes below that limit a significant net stabilization is achieved, yielding a potential transition delay that can exceed 100 percent of the length of the laminar region in the uncontrolled case.

Boundary layer stability↗

X-RAY EMISSION LINE PROFILES FROM WIND CLUMP BOW SHOCKS IN MASSIVE STARS

The consequences of structured flows continue to be a pressing topic in relating spectral data to physical processes occurring in massive star winds. In a preceding paper, our group reported on hydrodynamic simulations of hypersonic flow past a rigid spherical clump to explore the structure of bow shocks that can form around wind clumps. Here we report on profiles of emission lines that arise from such bow shock morphologies. To compute emission line profiles, we adopt a two-component flow structure of wind and clumps using two 'beta' velocity laws. While individual bow shocks tend to generate double-horned emission line profiles, a group of bow shocks can lead to line profiles with a range of shapes with blueshifted peak emission that depends on the degree of X-ray photoabsorption by the interclump wind medium, the number of clump structures in the flow, and the radial distribution of the clumps. Using the two beta law prescription, the theoretical emission measure and temperature distribution throughout the wind can be derived. The emission measure tends to be power law, and the temperature distribution is broad in terms of wind velocity. Although restricted to the case of adiabatic cooling, our models highlight the influence of bow shock effects for hot plasma temperature and emission measure distributions in stellar winds and their impact on X-ray line profile shapes. Previous models have focused on geometrical considerations of the clumps and their distribution in the wind. Our results represent the first time that the temperature distribution of wind clump structures are explicitly and self-consistently accounted for in modeling X-ray line profile shapes for massive stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Spatial and temporal variation in forest transpiration across a forested boreal peatland complex

Transpiration is a globally important component of evapotranspiration. Careful upscaling of transpiration from point measurements is thus crucial for quantifying water and energy fluxes. In spatially heterogeneous landscapes common across the boreal biome, upscaled transpiration estimates are difficult to determine due to variation in local environmental conditions (e.g., basal area, soil moisture, permafrost). Here, we sought to determine stand-level attributes that influence transpiration scalars for a forested boreal peatland complex consisting of sparsely treed wetlands and densely treed permafrost plateaus as land cover types. The objectives were to quantify spatial and temporal variability in stand-level transpiration, and to identify sources of uncertainty when scaling point measurements to the stand-level. Using heat ratio method sap flow sensors, we determined sap velocity for black spruce and tamarack for 2-week periods during peak growing season in 2013, 2017 and 2018. We found greater basal area, drier soils, and the presence of permafrost increased daily sap velocity in individual trees, suggesting that local environmental conditions are important in dictating sap velocity. When sap velocity was scaled to stand-level transpiration using gridded 20 × 20 m resolution data across the ~10 ha Scotty Creek ForestGEO plot, we observed significant differences in daily plot transpiration among years (0.17–0.30 mm), and across land cover types. Daily transpiration was lowest in grid-cells with sparsely treed wetlands compared to grid-cells with well-drained and densely treed permafrost plateaus, where daily transpiration reached 0.80 mm, or 30% of the daily evapotranspiration. When transpiration scalars (i.e., sap velocity) were not specific to the different land cover types (i.e., permafrost plateaus and wetlands), scaled stand-level transpiration was overestimated by 42%. To quantify the relative contribution of tree transpiration to ecosystem evapotranspiration, we recommend that sampling designs stratify across local environmental conditions to accurately represent variation associated with land cover types, especially with different hydrological functioning as encountered in rapidly thawing boreal peatland complexes.

54 ENVIRONMENTAL SCIENCES↗

Full Stall Simulations of a Redesigned Ventilation Fan for the ISS

The concept of a stall is studied rigorously in the aerospace industry. From a design standpoint, instabilities such as stall are undesirable– operation in the stall regime has a tremendous impact on aerodynamic performance as well as structural integrity. In extreme cases, operating in stall conditions can cause failure. Further, stall can cause a loss of lift on aircraft wings or a loss of thrust in aircraft engines. In any case, stall continues to be a topic of interest in the aerospace industry. The present work aims to analyze the stall characteristics of a ventilation fan that was recently designed for the International Space Station (ISS). Although the ventilation fan has a rotor-stator design, this paper considers a rotor-only configuration. The FUN3D Computational Fluid Dynamic (CFD) solver developed by NASA Langley Research Center was used to simulate the operational characteristics of the ventilation fan. FUN3D solves the Unsteady Reynolds-Averaged Naiver-Stokes (URANS) equations using implicit time marching and a dynamic overset grid. The FUN3D solver was originally written for exterior flow fields; however, this work represents an extension of the FUN3D solver to turbomachinery or interior flow fields. The FUN3D results for the rotor-only ventilation fan accurately captured the operational characteristics inherent to compressors– the results shared similar performance trends when compared to the experimental results for the rotor-stator case. A peak adiabatic efficiency of 96% occurred at a MFR of 105.2 CFM, the minimum aerodynamically stable point. A computationally stable stall occurred at a mass flow rate of 43.8 CFM where the adiabatic efficiency dropped to 69%.

CFD↗

Prediction of vortical flows on wings using incompressible Navier-Stokes equations

Grid-density and Reynolds-number effects on integral values and static pressure distributions are presently studied in the steady-state Navier-Stokes solutions obtained for the flow around a round-edged double delta wing using an upwind-relaxation finite-difference algorithm. It is found that while the computed longitudinal aerodynamic coefficients are in good agreement with extant experimental data, the magnitudes of suction-pressure peaks are underpredicted in the vicinity of the trailing edge. It is judged that additional computations employing finer-grid solutions in the vortical flow region are required.

Hsu, C.-H.↗

Nearly steady flows in GONG prototype data

Doppler velocity images obtained with the GONG prototype instrument were analyzed to measure the nearly steady photospheric flows. The data consists of 88 images each of velocity, intensity, and modulation obtained at 20:00 UT on 88 days from July 1992 to February 1994. Each velocity image was temporally filtered to remove the p-mode oscillations, masked to exclude active regions, and then analyzed using spherical harmonics and orthogonal functions as described by Hathaway (1992). The spectral coefficients show very consistent results for the entire time interval with some evidence of year-to-year variations. The rotation profile agrees well with previous results and exhibits a north-south asymmetry that reverses sign during the 20 month interval. The residual rotation velocities exhibit structures with amplitudes of approximately 5 m/s that may be related to torsional oscillations. The meridional circulation is directed from the equator toward the poles with a peak velocity in the photosphere of approximately 50 m/s. The higher order components are very weak but indicate a divergent flow from the mid-latitudes (opposite that found for the June 1989 data). The convective limb shift is well fit by a 3rd order polynomial. The convection spectrum has a prominent peak at spherical harmonic degrees of l approximately 150 with very little signal in the low degree modes. Analysis of this signal shows that there is no evidence for giant cell convection at the level of approximately 10 m/s for all modes up to l = 32.

Hathaway, David H.↗

Peak Oxygen Uptake during and after Long-duration Space Flight

Aerobic capacity (VO2peak) previously has not been measured during or after long-duration spaceflight. PURPOSE: To measure VO2peak and submaximal exercise responses during and after International Space Station (ISS) missions. METHODS: Astronauts (9 M, 5 F: 49 +/- 5 yr, 175 +/- 7 cm, 77.2 +/- 15.1 kg, 40.6 +/- 6.4 mL/kg/min [mean +/-SD]) performed graded peak cycle tests ~90 days before spaceflight, 15 d (FD15) after launch and every ~30 d thereafter during flight, and 1 (R+1), 10 (R+10), and 30 d (R+30) after landing. Oxygen consumption (VO2) and heart rate (HR) were measured from rest to peak exercise, while cardiac output (Q), stroke volume (SV), and arterial-venous oxygen difference (a-vO2diff) were measured only during rest and submaximal exercise. Data were analyzed using mixed-model linear regression. Body mass contributed significantly to statistical models, and thus results are reported as modeled estimates for an average subject. RESULTS: Early inflight (FD15) VO2peak was 17% lower (95% CI = - 22%, -13%) than preflight. VO2peak increased during spaceflight (0.001 L/min/d, P = 0.02) but did not return to preflight levels. On R+1 VO2peak was 15% (95% CI = -19%, -10%) lower than preflight but recovered to within 2% of preflight by R+30 (95% CI = -6%, +3%). Peak HR was not significantly different from preflight at any time. Inflight submaximal VO2 and a-vO2diff were generally lower than preflight, but the Q vs. VO2 slope was unchanged. In contrast, the SV vs. VO2 slope was lower (P < 0.001), primarily due to elevated SV at rest, and the HR vs. VO2 slope was greater (P < 0.001), largely due to elevated HR during more intense exercise. On R+1 although the relationships between VO2 and Q, SV, and HR were not statistically different than preflight, resting and submaximal exercise SV was lower (P < 0.001), resting and submaximal exercise HR was higher (P < 0.002), and a-vO2diff was unchanged. HR and SV returned to preflight levels by R+30. CONCLUSION: In the average astronaut VO2peak was reduced during spaceflight and immediately after landing but factors contributing to lower VO2peak may be different during spaceflight and recovery. Maintaining Q while VO2 is reduced inflight may be suggestive of an elevated blood flow to vascular beds other than exercising muscles, but decreased SV after flight likely reduces Q at peak exertion.

Moore, Alan D., Jr.↗

Motion and interaction of decaying trailing vortices in spanwise shear wind

A simulation is presented of the drift of trailing vortices in a cross-wind near the ground by an unsteady, two-dimensional, rotational flow field with a concentration of large vorticity in vortical spots (having a finite but small effective size and finite total strength). The problem is analyzed by a combination of the method of matched asymptotic analyses for the decay of the vortical spots and the Euler solution for the unsteady rotational flow. Using the method of averaging, a special numerical method is developed in which the grid size and time step depend only on the length and velocity scales of the background flow and are independent of the effective core size of a vortical spot. The core size can be much smaller than the grid size, whereas the peak velocity in the core is inversely propertional to the spot size. Numerical results are presented to demonstrate the strong interaction between the trajectories of the vortical spots and the change of the vorticity distribution in the background flow field.

Liu, C. H.↗

Free Flight Observation of a Separated Turbulent Flow Including Heat Transfer Up to Mach 8.5

A turbulent boundary layer separated by a forward-facing step was observed on the cylindrical portion of a hemisphere-cone-cylinder test vehicle. Tip blunting, producing a shear flow, was found to induce higher pressures on the cylindrical portion than were predicted from ballistic tunnel data of unblunted projectiles. An approximate method for predicting this blunt-body pressure distribution was hypothesized. These findings, along with the hypothesis, were substantiated by a wind tunnel test of a similar body. The peak pressure ratios of the separation were smaller in magnitude than flat plate theory predicted because of the effect of the shear flow. The decrement in heating of the separated flow, relative to the corresponding attached flow, was found to compare well with the expected results.

McConnell, Dudley George↗

Geothermal Energy for New Mexico: Assessment of Potential and Exploratory Drilling

This report summarizes the drilling operations and subsequent interpretation of thermal and geochemical data from the New Mexico Tech NMT-2GT (OSE RG- 05276 POD) test well. This slim hole was drilled along an elongate heat-flow anomaly at the base of the Socorro Mountains to better assess the geothermal resource potential (Socorro Peak geothermal system) on the western side of the New Mexico Tech campus in Socorro, New Mexico. The reservoir depth, hydraulic properties, temperature and chemistry were unknown prior to drilling. The purpose of the NMT-2GT (OSE RG-05276 POD) well was to explore the feasibility of providing geothermal fluids for a proposed district space heating system on the New Mexico Tech campus. With DOE cost over runs funds we completed NMT-2GT to a depth of 1102 feet at the Woods Tunnel drill site. Temperatures were nearly constant (41 oC ) between a depth of 1102 feet. Above this isothermal zone, a strong temperature gradient was observed (210 oC /km) beneath the water table consistent with vertical convective heat transfer. The existence of a groundwater upflow zone was further supported by measured vertical hydraulic head measurements which varied between about 258 feet at the water table to 155 feet at a depth of 1102 feet yielding a vertical hydraulic a gradient of about 0.1. If the upflow zone is 1 km deep, then a vertical flow rate is about 0.6 m/yr could have produced the observed curvature in the thermal profile. This would suggest that the deep bedrock permeability is about 20 mD. This is much lower than the permeability measured in a specific capacity aquifer test completed in 2009 within fracture Paleozoic sandstones near the water table (3000 D). Flow rates measured during drilling were measured using a v-notch weir. Flow rates were consistently around 1000 gpm. While the temperatures are lower than we had anticipated, this geothermal resource can still be developed to heat the NM Tech campus using heat pump technology.

15 GEOTHERMAL ENERGY↗

Experimental and Computational Investigation of the Tip Clearance Flow in a Transonic Axial Compressor Rotor

Experimental and computational techniques are used to investigate tip clearance flows in a transonic axial compressor rotor at design and part speed conditions. Laser anemometer data acquired in the endwall region are presented for operating conditions near peak efficiency and near stall at 100% design speed and at near peak efficiency at 60% design speed. The role of the passage shock/leakage vortex interaction in generating endwall blockage is discussed. As a result of the shock/vortex interaction at design speed, the radial influence of the tip clearance flow extends to 20 times the physical tip clearance height. At part speed, in the absence of the shock, the radial extent is only 5 times the tip clearance height. Both measurements and analysis indicate that under part-speed operating conditions a second vortex, which does not originate from the tip leakage flow, forms in the endwall region within the blade passage and exits the passage near midpitch. Mixing of the leakage vortex with primary flow downstream of the rotor at both design and part speed conditions is also discussed.

Suder, Kenneth L.↗

Structure and dynamics of the ionosphere

The structure of the Venus ionosphere and the major processes occurring within it are summarized. The daytime ionosphere is created by solar EUV radiation incident on the thermosphere; it is in photochemical equilibrium near its peak at about 142 km, where O2(+) is the major ion, and near diffusive equilibrium in its upper regions, where the major ion is O(+). The day-to-night plasma pressure gradient across the terminator drives a nightward ion flow which, together with electron precipitation, contributes to the formation of the nighttime ionosphere. Large-scale radial holes or plasma depletions extending downwards to nearly the ionization peak in the antisolar region are also observed which are associated with regions of strong radial magnetic fields. The ionopause is a highly dynamic and complex surface, extending from an average altitude of 290 km at the subsolar point to about 1000 km at the terminator and from 200 to over 3000 km on the nightside. A variety of solar wind interaction products are observed in the mantle, a transition region between the ionospheric plasma and the flowing shocked solar wind.

Nagy, A. F.↗

High-Frequency Excitation of a Plane Wake

In the early 1990's, Glezer and his co-workers at Georgia Tech made a startling discovery. They found that forcing at frequencies too high to directly affect the production scales led to a dramatic alteration in the development of a turbulent shear layer. An experimental study of this phenomenon is presented in Wiltse and Glezer. They used piezoelectric actuators located near the jet exit plane to force the shear layers of a square low-speed jet. The actuators were driven at a high frequency in the Kolmogorov inertial subrange, much higher than the frequencies associated with the large-scale motion (where the turbulent energy is produced and located) but much lower than those associated with the Kolmogorov scale (where the turbulent energy is dissipated). Measurements of the shear-layer turbulence showed that direct excitation of small-scale motion by high-frequency forcing led to an increase in the turbulent dissipation of more than an order of magnitude in the initial region of the shear layer! The turbulent dissipation gradually decreased with downstream distance but remained above the corresponding level for the unforced flow at all locations examined. The high-frequency forcing increased the turbulent kinetic energy in the initial region near the actuators, but the kinetic energy decreased quite rapidly with downstream distance, dropping to levels that were a small fraction of the level for the unforced case. Perhaps most importantly from the present standpoint, the high-frequency forcing significantly decreased the energy in the large-scale motion, increasingly so with downstream distance. Wiltse and Glezer interpreted this behavior as an enhanced transfer of energy from the large scales to the small scales. The initial work by Wiltse and Glezer has expanded into other applications. To explore the potential of high-frequency forcing for active acoustic suppression, in 1998 the first author proposed a set of experiments involving an edge tone shear layer and an open cavity flow. This work was funded by the US Air Force Research Laboratory, and the experiments were developed and executed at Boeing by Raman and Kibens. These experiments involved high-frequency forcing applied to low-speed flows using wedge piezo actuators and powered resonance tubes. The system is simple, open loop, compact, potentially requires little power, and is easily integrated. Dramatic results, such as reductions of 20 dB in spectral peaks and 5-8 dB in overall levels across the entire acoustic spectrum, were obtained in some cases. Sample results are presented. Following this success in low-speed flows, an international cooperative program continuing this work involved transonic experiments in a mid-size facility in the United Kingdom. Similar reductions in noise level were obtained in these transonic experiments. Discussion of this work is given in Raman et at. and Stanek, Raman, Kibens, and Ross. Other experiments at Georgia Tech have shown significant potential of high-frequency forcing in controlling reaction rates in chemically reacting flows.

Cain, Alan B.↗

Experimental investigation of dielectric barrier discharge plasma actuators driven by repetitive high-voltage nanosecond pulses with dc or low frequency sinusoidal bias

Experimental studies were conducted of a flow induced in an initially quiescent room air by a single asymmetric dielectric barrier discharge driven by voltage waveforms consisting of repetitive nanosecond high-voltage pulses superimposed on dc or alternating sinusoidal or square-wave bias voltage. To characterize the pulses and to optimize their matching to the plasma, a numerical code for short pulse calculations with an arbitrary impedance load was developed. A new approach for nonintrusive diagnostics of plasma actuator induced flows in quiescent gas was proposed, consisting of three elements coupled together: the schlieren technique, burst mode of plasma actuator operation, and two-dimensional numerical fluid modeling. The force and heating rate calculated by a plasma model was used as an input to two-dimensional viscous flow solver to predict the time-dependent dielectric barrier discharge induced flow field. This approach allowed us to restore the entire two-dimensional unsteady plasma induced flow pattern as well as characteristics of the plasma induced force. Both the experiments and computations showed the same vortex flow structures induced by the actuator. Parametric studies of the vortices at different bias voltages, pulse polarities, peak pulse voltages, and pulse repetition rates were conducted experimentally. The significance of charge buildup on the dielectric surface was demonstrated. The charge buildup decreases the effective electric field in the plasma and reduces the plasma actuator performance. The accumulated surface charge can be removed by switching the bias polarity, which leads to a newly proposed voltage waveform consisting of high-voltage nanosecond repetitive pulses superimposed on a high-voltage low frequency sinusoidal voltage. Advantages of the new voltage waveform were demonstrated experimentally.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗