Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “panel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Scintillator high-gain avalanche rushing photoconductor active-matrix flat panel imager: Zero-spatial frequency x-ray imaging properties of the solid-state SHARP sensor structure

Purpose: The authors are investigating the feasibility of a new type of solid-state x-ray imaging sensor with programmable avalanche gain: scintillator high-gain avalanche rushing photoconductor active matrix flat panel imager (SHARP-AMFPI). The purpose of the present work is to investigate the inherent x-ray detection properties of SHARP and demonstrate its wide dynamic range through programmable gain. Methods: A distributed resistive layer (DRL) was developed to maintain stable avalanche gain operation in a solid-state HARP. The signal and noise properties of the HARP-DRL for optical photon detection were investigated as a function of avalanche gain both theoretically and experimentally, and the results were compared with HARP tube (with electron beam readout) used in previous investigations of zero spatial frequency performance of SHARP. For this new investigation, a solid-state SHARP x-ray image sensor was formed by direct optical coupling of the HARP-DRL with a structured cesium iodide (CsI) scintillator. The x-ray sensitivity of this sensor was measured as a function of avalanche gain and the results were compared with the sensitivity of HARP-DRL measured optically. The dynamic range of HARP-DRL with variable avalanche gain was investigated for the entire exposure range encountered in radiography/fluoroscopy (R/F) applications. Results: The signal from HARP-DRL as a function of electric field showed stable avalanche gain, and the noise associated with the avalanche process agrees well with theory and previous measurements from a HARP tube. This result indicates that when coupled with CsI for x-ray detection, the additional noise associated with avalanche gain in HARP-DRL is negligible. The x-ray sensitivity measurements using the SHARP sensor produced identical avalanche gain dependence on electric field as the optical measurements with HARP-DRL. Adjusting the avalanche multiplication gain in HARP-DRL enabled a very wide dynamic range which encompassed all clinically relevant medical x-ray exposures. Conclusions: This work demonstrates that the HARP-DRL sensor enables the practical implementation of a SHARP solid-state x-ray sensor capable of quantum noise limited operation throughout the entire range of clinically relevant x-ray exposures. This is an important step toward the realization of a SHARP-AMFPI x-ray flat-panel imager.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Noise, sampling, and the number of projections in cone-beam CT with a flat-panel detector

Purpose: To investigate the effect of the number of projection views on image noise in cone-beam CT (CBCT) with a flat-panel detector. Methods: This fairly fundamental consideration in CBCT system design and operation was addressed experimentally (using a phantom presenting a uniform medium as well as statistically motivated “clutter”) and theoretically (using a cascaded systems model describing CBCT noise) to elucidate the contributing factors of quantum noise (σ{sub Q}), electronic noise (σ{sub E}), and view aliasing (σ{sub view}). Analysis included investigation of the noise, noise-power spectrum, and modulation transfer function as a function of the number of projections (N{sub proj}), dose (D{sub tot}), and voxel size (b{sub vox}). Results: The results reveal a nonmonotonic relationship between image noise andN{sub proj} at fixed total dose: for the CBCT system considered, noise decreased with increasing N{sub proj} due to reduction of view sampling effects in the regime N{sub proj} <∼200, above which noise increased with N{sub proj} due to increased electronic noise. View sampling effects were shown to depend on the heterogeneity of the object in a direct analytical relationship to power-law anatomical clutter of the form κ/f {sup β}—and a general model of individual noise components (σ{sub Q}, σ{sub E}, and σ{sub view}) demonstrated agreement with measurements over a broad range in N{sub proj}, D{sub tot}, and b{sub vox}. Conclusions: The work elucidates fairly basic elements of CBCT noise in a manner that demonstrates the role of distinct noise components (viz., quantum, electronic, and view sampling noise). For configurations fairly typical of CBCT with a flat-panel detector (FPD), the analysis reveals a “sweet spot” (i.e., minimum noise) in the rangeN{sub proj} ∼ 250–350, nearly an order of magnitude lower in N{sub proj} than typical of multidetector CT, owing to the relatively high electronic noise in FPDs. The analysis explicitly relates view aliasing and quantum noise in a manner that includes aspects of the object (“clutter”) and imaging chain (including nonidealities of detector blur and electronic noise) to provide a more rigorous basis for commonly held intuition and heurism in CBCT system design and operation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-16A-01: In Vivo Source Position Verification in High Dose Rate (HDR) Prostate Brachytherapy Using a Flat Panel Imager: Initial Clinical Experience

Purpose: We report our initial clinical experience with a novel position-sensitive source-tracking system based on a flat panel imager. The system has been trialled with 4 prostate HDR brachytherapy patients (8 treatment fractions) in this initial study. Methods: The flat panel imaging system was mounted under a customised carbon fibre couch top assembly (Figure 1). Three gold fiducial markers were implanted into the prostate of each patient at the time of catheter placement. X-ray dwell position markers were inserted into three catheters and a radiograph acquired to locate the implant relative to the imaging device. During treatment, as the HDR source dwells were delivered, images were acquired and processed to determine the position of the source in the patient. Source positions measured by the imaging device were compared to the treatment plan for verification of treatment delivery. Results: Measured dwell positions provided verification of relative dwell spacing within and between catheters, in the coronal plane. Measurements were typically within 2.0mm (0.2mm – 3.3mm, s.d. 0.8mm) of the planned positions over 60 dwells (Figure 2). Discrimination between larger dwell intervals and catheter differentiation were clear. This confirms important delivery attributes such as correct transfer tube connection, source step size, relative catheter positions and therefore overall correct plan selection and delivery. The fiducial markers, visible on the radiograph, provided verification of treatment delivery to the correct anatomical location. The absolute position of the dwells was determined by comparing the measured dwell positions with the x-ray markers from the radiograph, validating the programmed treatment indexer length. The total impact on procedure time was less than 5 minutes. Conclusion: The novel, noninvasive HDR brachytherapy treatment verification system was used clinically with minor impact on workflow. The system allows verification of correct treatment delivery, free of most potential human related errors identified in ICRP 97. This research is supported by funding from the Australian Government Department of Health through Cancer Australia grant no. 616614.

60 APPLIED LIFE SCIENCES↗

SU-E-I-07: Response Characteristics and Signal Conversion Modeling of KV Flat-Panel Detector in Cone Beam CT System

Purpose: The flat-panel detector response characteristics are investigated to optimize the scanning parameter considering the image quality and less radiation dose. The signal conversion model is also established to predict the tumor shape and physical thickness changes. Methods: With the ELEKTA XVI system, the planar images of 10cm water phantom were obtained under different image acquisition conditions, including tube voltage, electric current, exposure time and frames. The averaged responses of square area in center were analyzed using Origin8.0. The response characteristics for each scanning parameter were depicted by different fitting types. The transmission measured for 10cm water was compared to Monte Carlo simulation. Using the quadratic calibration method, a series of variable-thickness water phantoms images were acquired to derive the signal conversion model. A 20cm wedge water phantom with 2cm step thickness was used to verify the model. At last, the stability and reproducibility of the model were explored during a four week period. Results: The gray values of image center all decreased with the increase of different image acquisition parameter presets. The fitting types adopted were linear fitting, quadratic polynomial fitting, Gauss fitting and logarithmic fitting with the fitting R-Square 0.992, 0.995, 0.997 and 0.996 respectively. For 10cm water phantom, the transmission measured showed better uniformity than Monte Carlo simulation. The wedge phantom experiment show that the radiological thickness changes prediction error was in the range of (-4mm, 5mm). The signal conversion model remained consistent over a period of four weeks. Conclusion: The flat-panel response decrease with the increase of different scanning parameters. The preferred scanning parameter combination was 100kV, 10mA, 10ms, 15frames. It is suggested that the signal conversion model could effectively be used for tumor shape change and radiological thickness prediction. Supported by National Natural Science Foundation of China (81101132, 11305203) and Natural Science Foundation of Anhui Province (11040606Q55, 1308085QH138)

60 APPLIED LIFE SCIENCES↗

Source strength verification and quality assurance of preloaded brachytherapy needles using a CMOS flat panel detector

Purpose: Current methods of low dose rate brachytherapy source strength verification for sources preloaded into needles consist of either assaying a small number of seeds from a separate sample belonging to the same lot used to load the needles or performing batch assays of a subset of the preloaded seed trains. Both of these methods are cumbersome and have the limitations inherent to sampling. The purpose of this work was to investigate an alternative approach that uses an image-based, autoradiographic system capable of the rapid and complete assay of all sources without compromising sterility. Methods: The system consists of a flat panel image detector, an autoclavable needle holder, and software to analyze the detected signals. The needle holder was designed to maintain a fixed vertical spacing between the needles and the image detector, and to collimate the emissions from each seed. It also provides a sterile barrier between the needles and the imager. The image detector has a sufficiently large image capture area to allow several needles to be analyzed simultaneously.Several tests were performed to assess the accuracy and reproducibility of source strengths obtained using this system. Three different seed models (Oncura 6711 and 9011 {sup 125}I seeds, and IsoAid Advantage {sup 103}Pd seeds) were used in the evaluations. Seeds were loaded into trains with at least 1 cm spacing. Results: Using our system, it was possible to obtain linear calibration curves with coverage factor k = 1 prediction intervals of less than ±2% near the centre of their range for the three source models. The uncertainty budget calculated from a combination of type A and type B estimates of potential sources of error was somewhat larger, yielding (k = 1) combined uncertainties for individual seed readings of 6.2% for {sup 125}I 6711 seeds, 4.7% for {sup 125}I 9011 seeds, and 11.0% for Advantage {sup 103}Pd seeds. Conclusions: This study showed that a flat panel detector dosimetry system is a viable option for source strength verification in preloaded needles, as it is capable of measuring all of the sources intended for implantation. Such a system has the potential to directly and efficiently estimate individual source strengths, the overall mean source strength, and the positions within the seed-spacer train.

60 APPLIED LIFE SCIENCES↗

MO-E-BRB-03: Panel Member

In this interactive session, lung SBRT patient cases will be presented to highlight real-world considerations for ensuring safe and accurate treatment delivery. An expert panel of speakers will discuss challenges specific to lung SBRT including patient selection, patient immobilization techniques, 4D CT simulation and respiratory motion management, target delineation for treatment planning, online treatment alignment, and established prescription regimens and OAR dose limits. Practical examples of cases, including the patient flow thought the clinical process are presented and audience participation will be encouraged. This panel session is designed to provide case demonstration and review for lung SBRT in terms of (1) clinical appropriateness in patient selection, (2) strategies for simulation, including 4D and respiratory motion management, and (3) applying multi imaging modality (4D CT imaging, MRI, PET) for tumor volume delineation and motion extent, and (4) image guidance in treatment delivery. Learning Objectives: Understand the established requirements for patient selection in lung SBRT Become familiar with the various immobilization strategies for lung SBRT, including technology for respiratory motion management Understand the benefits and pitfalls of applying multi imaging modality (4D CT imaging, MRI, PET) for tumor volume delineation and motion extent determination for lung SBRT Understand established prescription regimes and OAR dose limits.

60 APPLIED LIFE SCIENCES↗

MO-F-201-04: Panel Member

The goal of this session is to provide guidance to medical physicists undergoing the American Board of Radiology certification process in therapeutic medical physics. This panel discussion will focus on parts 2 (computer-based) and 3 (oral) of the examination. Unlike the latter portions of the exam which are specialty-driven, part 1 is universal for all medical physics fields and will not be addressed. This session is structured into different topics that aim to guide the participants on how to successfully prepare for the board exams. The subjects of discussion will include timing and strategies for exam preparation, crucial differences in preparing for the clinical computer-based exam versus the oral exam, what study tools are currently available for each, etc. The panel discussion format will allow the speakers to collectively present their experience and advice relating to each topic and foment audience participation. Learning Objectives: Know the main differences between what is expected for parts 2 and 3 Know different resources for test preparation Know how to formulate a plan to best study for each part based on the specific skill set the two parts require Know how to best present his/her answers during the oral examination – demeanor, answer structure, etc.

60 APPLIED LIFE SCIENCES↗

MO-F-201-00: PANEL DISCUSSION: Preparing for Parts 2 and 3 of the ABR Therapy Medical Physics Exam

The goal of this session is to provide guidance to medical physicists undergoing the American Board of Radiology certification process in therapeutic medical physics. This panel discussion will focus on parts 2 (computer-based) and 3 (oral) of the examination. Unlike the latter portions of the exam which are specialty-driven, part 1 is universal for all medical physics fields and will not be addressed. This session is structured into different topics that aim to guide the participants on how to successfully prepare for the board exams. The subjects of discussion will include timing and strategies for exam preparation, crucial differences in preparing for the clinical computer-based exam versus the oral exam, what study tools are currently available for each, etc. The panel discussion format will allow the speakers to collectively present their experience and advice relating to each topic and foment audience participation. Learning Objectives: Know the main differences between what is expected for parts 2 and 3 Know different resources for test preparation Know how to formulate a plan to best study for each part based on the specific skill set the two parts require Know how to best present his/her answers during the oral examination – demeanor, answer structure, etc.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-F-201-01: Panel Member

The goal of this session is to provide guidance to medical physicists undergoing the American Board of Radiology certification process in therapeutic medical physics. This panel discussion will focus on parts 2 (computer-based) and 3 (oral) of the examination. Unlike the latter portions of the exam which are specialty-driven, part 1 is universal for all medical physics fields and will not be addressed. This session is structured into different topics that aim to guide the participants on how to successfully prepare for the board exams. The subjects of discussion will include timing and strategies for exam preparation, crucial differences in preparing for the clinical computer-based exam versus the oral exam, what study tools are currently available for each, etc. The panel discussion format will allow the speakers to collectively present their experience and advice relating to each topic and foment audience participation. Learning Objectives: Know the main differences between what is expected for parts 2 and 3 Know different resources for test preparation Know how to formulate a plan to best study for each part based on the specific skill set the two parts require Know how to best present his/her answers during the oral examination – demeanor, answer structure, etc.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-F-201-03: Panel Member

The goal of this session is to provide guidance to medical physicists undergoing the American Board of Radiology certification process in therapeutic medical physics. This panel discussion will focus on parts 2 (computer-based) and 3 (oral) of the examination. Unlike the latter portions of the exam which are specialty-driven, part 1 is universal for all medical physics fields and will not be addressed. This session is structured into different topics that aim to guide the participants on how to successfully prepare for the board exams. The subjects of discussion will include timing and strategies for exam preparation, crucial differences in preparing for the clinical computer-based exam versus the oral exam, what study tools are currently available for each, etc. The panel discussion format will allow the speakers to collectively present their experience and advice relating to each topic and foment audience participation. Learning Objectives: Know the main differences between what is expected for parts 2 and 3 Know different resources for test preparation Know how to formulate a plan to best study for each part based on the specific skill set the two parts require Know how to best present his/her answers during the oral examination – demeanor, answer structure, etc.

61 RADIATION PROTECTION AND DOSIMETRY↗

Panel-Segmentation [SWR-21-18]

Panel-Segmentation contains the scripts for automated metadata extraction of solar PV installations, using satellite imagery coupled with computer vision techniques. In this package, the user can perform the following actions: *Automatically generate a satellite image using a set of lat-long coordinates, and a Google Maps API key. Users would need to set up a Google Cloud account and get a Maps Static API key. Please refer to Setting Up Google Maps Static API Key section for this process. *Perform image segmentation on the satellite image, to locate the solar array(s) in the image on a pixel-by-pixel basis, using an image segmentation model (panel_detection_model.pth). Get classification of the installation (rooftop, ground mounted fixed-tilt or tracking, carport, etc). *Perform azimuth estimation on each solar array cluster in the masked image. *Detect solar panels and get its latitude, longitude, and address within a geographic bounding box through the SOL-Searcher Pipeline. *Detect and calculate hurricane damage on solar installations given pre-hurricane and post-hurricane satellite imagery through the Hurricane Detection Pipeline. *Detect and calculate hail damage on solar installations given satellite imagery through the Hail Detection pipeline. *Convert NOAA MESH (Maximum Estimated Size of Hail) grib2 files into kml or geojson files. *Estimate tilt and azimuth of a solar array by processing USGS LiDAR data for the array’s location.

Edun, Ayobami↗

AQUEOUS HOMOGENEOUS REACTORTECHNICAL PANEL REPORT

Considerable interest has been expressed for developing a stable U.S. production capacity for medical isotopes and particularly for molybdenum- 99 (99Mo). This is motivated by recent re-ductions in production and supply worldwide. Consistent with U.S. nonproliferation objectives, any new production capability should not use highly enriched uranium fuel or targets. Conse-quently, Aqueous Homogeneous Reactors (AHRs) are under consideration for potential 99Mo production using low-enriched uranium. Although the Nuclear Regulatory Commission (NRC) has guidance to facilitate the licensing process for non-power reactors, that guidance is focused on reactors with fixed, solid fuel and hence, not applicable to an AHR. A panel was convened to study the technical issues associated with normal operation and potential transients and accidents of an AHR that might be designed for isotope production. The panel has produced the requisite AHR licensing guidance for three chapters that exist now for non-power reactor licensing: Reac-tor Description, Reactor Coolant Systems, and Accident Analysis. The guidance is in two parts for each chapter: 1) standard format and content a licensee would use and 2) the standard review plan the NRC staff would use. This guidance takes into account the unique features of an AHR such as the fuel being in solution; the fission product barriers being the vessel and attached systems; the production and release of radiolytic and fission product gases and their impact on operations and their control by a gas management system; and the movement of fuel into and out of the reactor vessel.

07 ISOTOPE AND RADIATION SOURCES↗

EMSL Geochemistry, Biogeochemistry and Subsurface Science-Science Theme Advisory Panel Meeting

This report covers the topics of discussion and the recommendations of the panel members. On December 8 and 9, 2010, the Geochemistry, Biogeochemistry, and Subsurface Science (GBSS) Science Theme Advisory Panel (STAP) convened for a more in-depth exploration of the five Science Theme focus areas developed at a similar meeting held in 2009. The goal for the fiscal year (FY) 2011 meeting was to identify potential topical areas for science campaigns, necessary experimental development needs, and scientific members for potential research teams. After a review of the current science in each of the five focus areas, the 2010 STAP discussions successfully led to the identification of one well focused campaign idea in pore-scale modeling and five longer-term potential research campaign ideas that would likely require additional workshops to identify specific research thrusts. These five campaign areas can be grouped into two categories: (1) the application of advanced high-resolution, high mass accuracy experimental techniques to elucidate the interplay between geochemistry and microbial communities in terrestrial ecosystems and (2) coupled computation/experimental investigations of the electron transfer reactions either between mineral surfaces and outer membranes of microbial cells or between the outer and inner membranes of microbial cells.

54 ENVIRONMENTAL SCIENCES↗

Predictive Science Panel: LLNL Meeting, 9-11 October 2012 (Unclassified Report)

The Predictive Science Panel (PSP) held its annual meeting at LLNL on 9-11 October 2012. The meeting included a half day of overview presentations, following by 1 ½ days of "deep dive" sessions: NBI Reconfiguration, Transport Algorithms, Ignition Prediction, and Safety and Surety. There was also a discussion of LANL's feedback on the PSP's March 20212 report. This document provides an unclassified summary of the Panel's observations. Significantly more detail is provided in the PSP's classified report.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Optical Encoding Technology for Viral Screening Panels (CRADA Final Report)

This was a collaborative effort between Lawrence Livermore National Security, LLC, Lawrence Livermore National Laboratory (LLNL) and Parallel Synthesis Technologies, Inc. (PSTI), to develop Optical Encoding Technology for Viral Screening Panels. The goal for this effort was to prepare a portable bead reader system that would enable the development of viral and bacterial screening panels which could be used for the detection of any desired set of bacteria or viruses in any location. The main objective was to determine if the combination of a bead-based, PCR suspension array technology, formulated from Parallume encoded beads and PSTI’s multiplex assay reader system (MARS), could provide advantages in terms of the number of simultaneously measured samples, portability, ruggedness, ease of use, accuracy, precision or cost as compared to the Luminex-based system developed at LLNL. The project underwent several no cost extensions however the overall goal of demonstrating the utility of this new system was achieved. As a result of the project a significant change to the type of bead PSTI used for the suspension system was implemented allowing better performance than the commercial Luminex system.

Lenhoff, Raymond J.↗

Evaluation of Rupture Panels M1, M2, and M3

In December 2012, four rupture panels, from Q42T, Q22T, Q22B and Q45B, have been found leaking during inspection. Three of these panels, which have only been in service since April 2012, belong to the most recently purchased lots in 2011.

42 ENGINEERING↗

2013 Predictive Science Panel Meeting Summary Report

The Predictive Science Panel (PSP) met at LANL on 12-14 March 2013. The Panel appreciated the frank and open discussion of some very difficult issues with which LANL is grappling with. The meeting consisted of four related deep-dive sessions: (1) Certification – Strategies and challenges for Reuse; (2) Certification – The impact of Pu aging; (3) Certification – The role of subcritical experiments; (4) Certification – First campaigns for MaRIE 1.0 There was also discussion of LLNL’s feedback from the October 2012 report and a poster session featuring excellent work by early-career scientists and engineers.

97 MATHEMATICS AND COMPUTING↗

Concentrating Solar Power Central Receiver Panel Component Fabrication and Testing (Final Report)

The objective of this project is to complete a design of an advanced concentrated solar panel and demonstrate the manufacturability of key components. Then confirm the operation of the key components under prototypic solar flux conditions. This work is an important step in reducing the levelized cost of energy (LCOE) from a central receiver solar power plant. The key technical risk to building larger power towers is building the larger receiver systems. Therefore, this proposed technology project includes the design of an advanced molten salt prototypic sub-scale receiver panel that can be utilized into a large receiver system. Then complete the fabrication and testing of key components of the receive design that will be used to validate the design.