Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nuclear detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Preliminary Investigation in removing microphonic noise from nuclear detectors

Developing tools to perform nuclear spectroscopy using unattended sensor nodes would greatly enhance LANL’s ability to address nuclear material identification and detection challenges in the non‐proliferation and treaty verification domains. High purity germanium crystals are the gold standard detector used for performing high‐resolution nuclear spectroscopy. In order to function properly, these crystals must be brought down to liquid nitrogen temperatures. In practice the required temperature is typically achieved using liquid nitrogen dewars. The shortcoming with this strategy is that the dewars must be refilled roughly every week. This requirement is not practical for applications that require collecting nuclear spectroscopy data in remote/inaccessible areas. An alternative is to use a piston‐driven cryocooler to achieve liquid nitrogen temperatures. Piston‐driven cryocoolers, can operate unattended, but the microphonic noise induced by the vibrations produced by these coolers causes the resolution of the spectroscopic measurements to severely degrade, making identification of nuclear materials significantly more difficult. The goal of this research effort was to reduce the effects of microphonic noise.

42 ENGINEERING↗

IAEA Sampling Plan

The objectives for this presentation are to describe the method that the IAEA uses to determine a sampling plan for nuclear material measurements; describe the terms detection probability and significant quantity; list the three nuclear materials measurement types; describe the sampling method applied to an item facility; and describe multiple method sampling.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Flow Characteristics of Intermediate Heat Exchanger with CFD Methodology on Nuclear Safety Application

The intermediate heat exchanger (IHX) plays an important role in the field of nuclear power plant, and its safety margin could strongly affected by the flow distribution of secondary flow inlet. As a result, the size of secondary inlet is crucial in thermal design. However, the IHX contains thousands of heat exchanger tubes, and it takes larger time to simulate each tube accurately. Other than that, there are more delicate devices in a nuclear power plant, so it would take too much time to simulate actual model. Although system code could solve problems effectively, it could not detect local deformation. On nuclear safety application, how to save time and receive specific results in an efficient way is necessary. Therefore, the porous media model and the heat exchanger model from computational fluid dynamics (CFD) were adopted in this study. The methodology not only can save much time than actual model but also receive more specific results than system code. To ensure the accuracy, validation of the methodology is also presented in this study by modeling RHR heat exchanger of L nuclear power plant. The results of the simulation were compared to experimental values from L nuclear power plant and receive small errors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SHIELDING AND DETECTOR RESPONSE CALCULATIONS PERTAINING TO CATEGORY 1 QUANTITIES OF PLUTONIUM AND HAND-HELD PLASTIC SCINTILLATORS

Nuclear facilities sometimes use hand-held plastic scintillator detectors to detect attempts to divert special nuclear material in situations where portal monitors are impractical. MCNP calculations have been performed to determine the neutron and gamma radiation field arising from a Category I quantity of weapons-grade plutonium in various shielding configurations. The shields considered were composed of combinations of lead and high-density polyethylene such that the mass of the plutonium plus shield was 22.7 kilograms. Monte-Carlo techniques were also used to determine the detector response to each of the shielding configurations. The detector response calculations were verified using field measurements of high-, medium-, and low- energy gamma-ray sources as well as a Cf-252 neutron source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Multi-Contact, Low Capacitance HPGe Detector for High Rate Gamma Spectroscopy

The detection, identification and non-destructive assay of special nuclear materials and nuclear fission by-products are critically important activities in support of nuclear non-proliferation programs. Both national and international nuclear safeguard agencies recognize that current accounting methods for spent nuclear fuel are inadequate from a safeguards perspective. Radiation detection and analysis by gamma-ray spectroscopy is a key tool in this field, but no instrument exists that can deliver the required performance (energy resolution and detection sensitivity) in the presence of very high background count rates encountered in the nuclear safeguards arena. The work of this project addresses this critical need by developing a unique gamma-ray detector based on high purity germanium that has the previously unachievable property of operating in the 1 million counts-per-second range while achieving state-of-the-art energy resolution necessary to identify and analyze the isotopes of interest. The technical approach was to design and fabricate a germanium detector with multiple segmented electrodes coupled to multi-channel high rate spectroscopy electronics. Dividing the germanium detector’s signal electrode into smaller sections offers two advantages; firstly, the energy resolution of the detector is potentially improved, and secondly, the detector is able to operate at higher count rates. The design challenges included the following; determining the optimum electrode configuration to meet the stringent energy resolution and count rate requirements; determining the electronic noise (and therefore energy resolution) of the completed system after multiple signals are recombined; designing the germanium crystal housing and vacuum cryostat; and customizing electronics to perform the signal recombination function in real time. In this phase I work, commercial off-the-shelf electrostatic modeling software was used to develop the segmented germanium crystal geometry, which underwent several iterations before an optimal electrode configuration was found. The model was tested and validated against real-world measurements with existing germanium detectors. Extensive modeling of electronic noise was conducted using established formulae, and real-world measurements were performed on candidate front-end electronic components. This initial work proved the feasibility of the design with respect to expected high count rate and energy resolution performance. Phase I also delivered the mechanical design of the detector housing and vacuum cryostat to be built in Phase II. Finally, a Monte Carlo simulation was created to show the response of the complete design to a Cs-137 source. This development presents a significant advance for nuclear safeguards instrumentation with increased speed and accuracy of detection and identification of special nuclear materials. Other significant applications are foreseen for a gamma-ray detector that delivers high energy resolution (1keV FWHM noise) at high count rate (1 Mcps), especially in the areas of physics research and materials analysis.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

THE DISCOVERY OF HOST GALAXY H I ABSORPTION IN CTA 21

We report the discovery of H I 21 cm absorption toward the well-studied Gigahertz peaked spectrum source CTA 21 (4C 16.09) using the Arecibo telescope on 2009 September 20 and 21. Recently, the frequency band between 700 and 800 MHz was temporarily opened up to radio astronomy when US TV stations were mandated to switch from analog to digital transmissions, with new frequency allocations. The redshifted H I frequency for CTA 21 falls within this band. CTA 21 has a complex radio structure on a range of scales. The innermost prominent components are separated by {approx}12 mas while weak diffuse emission extends for up to {approx}300 mas. The H I absorption profile that we find has two main components, one narrow and the other wider and blueshifted. The total H I column density is 7.9 x 10{sup 20} cm{sup -2}, assuming a covering factor of unity and a spin temperature of 100 K. This H I absorption confirms the recently determined optical redshift of this faint galaxy of z {approx} 0.907. We discuss this new detection in light of H I absorption studies toward compact radio sources, and also the possibility that CTA 21 may be exhibiting multiple cycles of nuclear activity. This new detection in CTA 21 is consistent with a strong trend for detection of H I absorption in radio galaxies with evidence of episodic nuclear/jet activity.

79 ASTRONOMY AND ASTROPHYSICS↗

High-fidelity photoneutron detection via neutron activation analysis

To interdict illicit radioactive sources and prevent nuclear terror, governments have deployed portal monitor systems at ports of entry. Such portal monitors rely upon the detection of spontaneously-emitted radiation signatures, however, detection scenarios become more challenging for highly enriched uranium, which emits relatively few spontaneous radiation signatures. Photon active interrogation techniques can augment current cargo inspection scenarios and improve detection capabilities for illicit nuclear material. A high-energy photon interrogation source can induce photofission in nuclear material, producing strong radiation signatures for detection. Prompt fission signals are of specific interest because prompt neutrons are greater than 99% of the fission signal. When using detectors capable of spectroscopy, e.g., pulse shape discrimination-capable organic scintillators, the intense interrogating source often will cause pulse pile-up, degrading particle classification. In this work, we demonstrate photoneutron detection via neutron activation of aluminum and iron. The experiments rely upon nuclear reactions that can only be induced by neutrons, and are robust against pile-up, thereby providing high-confidence neutron rates. In this work, we apply neutron activation analysis for the detection of high-energy neutrons produced by high-energy photon irradiation; the depleted uranium sample was irradiated with a 9-MeV bremsstrahlung beam. We find that the irradiated depleted uranium produced an aluminum activation flux of 1.77 × 10 5 n cm –2 s –1 and an iron-56 activation flux of 1.05 × 10 5 n cm –2 s –1 . Furthermore, the ability to detect radioactivity induced by neutrons created in (, n) and photofission reactions demonstrates a new approach for photon active interrogation to identify nuclear materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel synthesis and structural characterization of a high-affinity paramagnetic kinase probe for the identification of non-ATP site binders by nuclear magnetic resonance.

To aid in the pursuit of selective kinase inhibitors, we have developed a unique ATP site binder tool for the detection of binders outside the ATP site by nuclear magnetic resonance (NMR). We report here the novel synthesis that led to this paramagnetic spin-labeled pyrazolopyrimidine probe (1), which exhibits nanomolar inhibitory activity against multiple kinases. We demonstrate the application of this probe by performing NMR binding experiments with Lck and Src kinases and utilize it to detect the binding of two compounds proximal to the ATP site. The complex structure of the probe with Lck is also presented, revealing how the probe fits in the ATP site and the specific interactions it has with the protein. We believe that this spin-labeled probe is a valuable tool that holds broad applicability in a screen for non-ATP site binders.

59 BASIC BIOLOGICAL SCIENCES↗

Maximum Likelihood Source Localization Using Elpasolite as a Dual Gamma Neutron Directional Detector

The problem of accurately detecting extremely low levels of nuclear radiation is rapidly increasing in importance in nuclear counter-proliferation, verification, and environmental and waste management. Because the 239Pu gamma signature may be weak, for instance, even when compared to the natural terrestrial background, coincidence counting with the 239Pu neutron signature may improve overall 239Pu detection sensitivity. However, systems with sufficient multiple-particle detectors require demonstration that the increased sensitivity be sufficiently high to overcome added cost and weight. We report the results of measurements and calculations to determine sensitivity that can be gained in detecting low levels of nuclear radiation from use of a relatively new detector technology based on elpasolite crystals. We have performed investigations exploring cerium (Ce3+)-doped elpasolites Cs2LiYCl6:Ce3+0.5% (CLYC) and Cs2LiLa(Br6)90%(Cl6)10%:Ce3+0.5% (CLLBC:Ce). These materials can provide energy resolution (r(E) = 2.35σ(E)/E) as good as 2.9% at 662 keV (FWHM). The crystals show an excellent neutron and gamma radiation response. The goals of the investigation were to set up the neutron/gamma pulse shape discrimination electronics for elpasolite detectors; perform limited static source benchmarking, testing, and evaluation to validate system performance; and explore application of a maximum likelihood algorithm for source location. Data were measured and processed through a maximum likelihood estimation algorithm, providing a direction to the radioactive source for each individual position. The estimated directions were good representations for the actual directions to the radioactive source. This paper summarizes the maximum likelihood results for our elpasolite system.

maximum likelihood, radiation detectors, neutron d↗

New Developments and Applications of Superheated Emulsions: Warhead Verification and Special Nuclear Material Interdiction

In recent years, neutron detection with superheated emulsions has received renewed attention thanks to improved detector manufacturing and read-out techniques, and thanks to successful applications in warhead verification and special nuclear material (SNM) interdiction. Detectors are currently manufactured with methods allowing high uniformity of the drop sizes, which in turn allows the use of optical read-out techniques based on dynamic light scattering. Furthermore, small detector cartridges arranged in 2D matrices are developed for the verification of a declared warhead without revealing its design. For this application, the enabling features of the emulsions are that bubbles formed at different times cannot be distinguished from each other, while the passive nature of the detectors avoids the susceptibility to electronic snooping and tampering. Large modules of emulsions are developed to detect the presence of shielded special nuclear materials hidden in cargo containers ‘interrogated’ with high energy X-rays. In this case, the enabling features of the emulsions are photon discrimination, a neutron detection threshold close to 3 MeV and a rate-insensitive read-out.

d’Errico, Francesco↗

A Perspective on information fusion problems, Extended Abstract, Journal of Distributed Sensor Neworks

Information fusion problems have a rich history spanning four centuries and several disciplines as diverse as political economy, reliability engineering, target tracking, bioinformatics, forecasting, distributed detection, robotics, cyber security, nuclear engineering, distributed sensor networks, and others. Over the past decade, the area of information fusion has been established as a discipline by itself with several contributions to its foundations as well as applications. In a basic formulation of the information fusion problem, each component is characterized by a probability distribution. The goal is to estimate a fusion rule for combining the outputs of components to achieve a specified objective such as better performance or functionality compared to the components. If the sensor error distributions are known, several fusion rule estimation problems have been formulated and solved using deterministic methods. In the area of pattern recognition a weighted majority fuser was shown to be optimal in combining outputs from pattern recognizers under statistical independence conditions. A simpler version of this problem corresponds to the Condorcet Jury theorem proposed in 1786. This result was rediscovered since then in other disciplines including by von Neumann in 1959 in building reliable computing devices. The distributed detection problem, studied extensively in the target tracking area, can be viewed as a generalization of the above two problems. In these works, the underlying distributions are assumed to be known, which is quite reasonable in the areas these methods are applied. In a different formulation, we consider estimating the fuser based on empirical data when no information is available about the underlying distributions of components. Using the empirical estimation methods, this problem is shown to be solvable in principle, and the fuser performance may be sharpened based on the specific formulation. The isolation fusers perform at least as good as best component, and the projective fusers perform as good as best combination of components. In a special case of function estimation, each component could be a potential function estimator, radial basis function, nearest neighbor estimator, regressogram, kernel estimator, regression tree or another estimator. A projective fuser based on a nearest neighbor concept has been proposed based on Voronoi regions in this case. Under fairly general smoothness and non-smoothness conditions on the individual estimators, the expected fuser error is close to optimal with a specified probability. This result is purely sample-based and distribution-free in that it does not require the knowledge of underlying distributions and can be computed only using measurements.

99 GENERAL AND MISCELLANEOUS↗

Integration of Nuclear Material Accounting Data and Process Monitoring Data for Improvement on Detection Probability in Safeguarding Electrochemical Processing Facilities (Final Technical Report)

The KAERI advanced spent fuel conditioning process (ACP) process is a critical component of the US- South Korean nuclear cooperation and the following “123 Agreement.” Its development has received considerable attention in both countries. The ACP is an electrochemical processing (pyroprocessing) that recycles over 96% of the used nuclear fuel (UNF). It is also intrinsically proliferation-resistant in theory. In normal operation, the U/TRU product is very hot radiologically. In addition, the Cm provides a high level of spontaneous neutrons, making the product unsuitable for weapon use. However, as pointed in some study, “the need for safeguards to protect against the diversion and misuse of separated plutonium applies essentially equally to all grades of plutonium.” As pointed by many studies, the well-established traditional Nuclear Material Accounting (NMA) approach cannot be directly applied to electrochemical processing because of the lack of an input accountability tank, the non-continuous material flow, and the unsatisfactory level of confidence in sampling methods. Therefore, nuclear safeguards remain a grand challenge in the developing of commercial electrochemical separations facilities, especially around the heart of such facilities, the electrorefiner (ER) systems. In contrast to NMA data, process monitoring (PM) data is normally an indirect measurement of the SNM and is acquired much more frequently. In a broad sense, PM includes monitoring by various types of equipment, e.g. radiation detectors, cameras, voltage, current sensors. Because it is already being collected by the operator, the additional cost to safeguards is low. It has long been believed that PM data can supplement NMA data and help improve safeguards, although the benefits are hard to quantify. The U.S. DOE’s Material Protection, Accounting, and Control Technology (MPACT) campaign has made substantial investments into innovative PM sensor technology and predictive model development for real- or near real-time measurement and prediction of molten salt density and level, salt composition and actinide concentration especially Pu, the cell voltage, and the cell current to supplement traditional NMA. For aqueous-based reprocessing facilities, it is reported that PM, integrated with traditional NMA, have a high detection probability for specific diversions. For electrochemical reprocessing, preliminary studies have shown that PM data can support traditional NMA in various ways by providing a basis to estimate some of the in-processing nuclear material inventories. Despite early success, further studies on fusion of PM data and NMA data are still needed, which is the goal of this proposed work.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Angra Project: Monitoring Nuclear Reactors with Antineutrino Detectors

We present the status of the Angra Neutrino project, describing the development of an antineutrino detector aimed at monitoring nuclear reactor activity. The experiment will take place at the Brazilian nuclear power plant located in Angra dos Reis. The Angra II reactor, with 4 GW of thermal power, will be used as a source of antineutrinos. A water Cherenkov detector will be placed above ground in a commercial container outside the reactor containment, about 30 m from the reactor core. With a detector of one ton scale a few thousand antineutrino interactions per day are expected. We intend, in a first step, to use the measured neutrino event rate to monitor the on--off status and the thermal power delivered by the reactor. In addition to the safeguards issues the project will provide an alternative tool to have an independent measurement of the reactor power.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Double-stranded RNA-dependent kinase PKR activates NF-κB pathway in acute pancreatitis

The activation of transcription factor nuclear factor kappa B (NF-κB) occurs early in acute pancreatitis (AP) simultaneously with intracellular trypsinogen activation. Double-stranded RNA-dependent kinase (PKR) promotes the activation of NF-κB and the production of pro-inflammatory factors including tumor necrosis factor alpha (TNF-α) and interleukin 6 (IL-6). The rat and rat pancreatic AR42J cells were treated by cerulein to establish AP models, showing PKR increased. TNF-α, IL-6 and lactate dehydrogenase (LDH) in AP pancreatic tissues and cerulein-treated AR42J cells increased, while PKR knockdown in AR42J cells reversed cerulein-induced inflammatory response and pancreatic cell injury. In addition, inhibitor of kappa B kinase α (IKKα), phosphorylated P65 (p-P65), P65 increased in cerulein-treated AR42J cells. Meanwhile, in cerulein-treated AR42J cells, interaction between PKR and IKKα, as well as the co-localization and nuclear accumulation of PKR and P65, were detected. Furthermore, cerulein induced the phosphorylation and nuclear translocation of P65, which indicated the activation of NF-κB, while PKR knockdown hindered NF-κB activation to alleviate pancreatic cell injury. In summary, PKR might promote NF-κB activation via facilitating its phosphorylation and nuclear translocation, thus accelerated inflammatory response and pancreatic cell injury in AP, implying a novel molecular target for the treatment of AP.

60 APPLIED LIFE SCIENCES↗

Dispersion of Silicate in Tricalcium Phosphate Elucidated by Solid-State NMR

The dispersion of silicate in tricalcium phosphate, a resorbable bioceramics for bone replacement, has been investigated by various solid-state nuclear magnetic resonance (NMR) methods. In samples prepared with 5 and 10 mol% of both {sup 29}SiO{sub 2} and ZnO, three types of silicate have been detected: (i) SiO{sub 4}{sup 4-} (Q{sub 0} sites) with long longitudinal (T{sub 1,Si}) relaxation times ({approx} 10,000 s), which substitute for {approx}1% of PO{sub 4}{sup 3-}; (ii) silicate nanoinclusions containing Q{sub 2}, Q{sub 1}, and Q{sub 0} sites with T{sub 1,Si} 100 s, which account for most of the silicon; and (iii) crystalline Q{sub 4} (SiO{sub 2}) with long T{sub 1,Si}. Sensitivity was enhanced >100-fold by {sup 29}Si enrichment and refocused detection. The inclusions in both samples have a diameter of {approx}8 nm, as proved by {sup 29}Si{l_brace}{sup 31}P{r_brace} REDOR dephasing on a 30-ms time scale, which was simulated using a multispin approach specifically suited for nanoparticles. {sup 29}Si CODEX NMR with 30-s {sup 29}Si spin diffusion confirms that an inclusion contains >10 Si (consistent with the REDOR result of >100 Si per inclusion). Overlapping signals of silicate Q{sub 2}, Q{sub 1}, and Q{sub 0} sites were spectrally edited based on their J-couplings, using double-quantum filtering. The large inhomogeneous broadening of the Q{sub 2}, Q{sub 1}, and Q{sub 0} {sup 29}Si subspectra indicates that the nanoinclusions are amorphous.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-fidelity entanglement and coherent multi-qubit mapping in an atom array

Neutral atoms in optical tweezer arrays possess broad applicability for quantum technologies, such as computing, analogue simulation and metrology. The atomic species ytterbium-171 is able to host multiple types of qubits, making it a strong candidate for bridging various applications of tweezer arrays. Realizing this potential requires high-fidelity generation and transfer of many-body entanglement between these distinct qubit degrees of freedom. Here, in this study, we demonstrate the creation and coherent mapping of entangled quantum states across multiple qubits in ytterbium-171 tweezer arrays. We map entangled states onto the optical clock qubit from the nuclear spin qubit or the Rydberg qubit. We coherently transfer Z 2 -ordered Greenberger–Horne–Zeilinger states of up to 20 atoms from the interacting Rydberg manifold to the metastable nuclear spin manifold. Furthermore, we find that clock-qubit-based spin detection, when applied to Rydberg and nuclear spin qubits, facilitates atom-loss-detectable qubit measurements and Rydberg decay detection. This enables delayed-erasure detection, yielding an error-detected two-qubit gate fidelity of 99.78(4)% in metastable qubits. These results establish a versatile architecture that advances multiple fields of quantum information science while also establishing bridges between them.

Senoo, Aruku [University of Colorado, Boulder, CO ↗

Nondestructive Assay for Nuclear Safeguards [Slides]

The objective of safeguards is the timely detection of diversion of significant quantities of nuclear material from peaceful nuclear activities to the manufacture of nuclear weapons. Currently, the IAEA is working to achieve universal acceptance of the AP, safeguards-by-design, unattended monitoring & data integration, and state-level concept/approach. We are trying to verify special nuclear material (SNM) is where it should be, and in the proper amount.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

UNVEILING EXTRAGALACTIC STAR FORMATION USING RADIO RECOMBINATION LINES: AN EXPANDED VERY LARGE ARRAY PILOT STUDY WITH NGC 253

Radio recombination lines (RRLs) are powerful, extinction-free diagnostics of the ionized gas in young, star-forming regions. Unfortunately, these lines are difficult to detect in external galaxies. We present the results of Expanded Very Large Array (EVLA) observations of the RRL and radio continuum emission at 33 GHz from NGC 253, a nearby nuclear starburst galaxy. We detect the previously unobserved H58{alpha} and H59{alpha} RRLs and make simultaneous sensitive measurements of the continuum. We measure integrated line fluxes of 44.3 {+-} 0.7 W m{sup -2} and 39.9 {+-} 0.8 W m{sup -2} for the H58{alpha} and H59{alpha} lines, respectively. The thermal gas in NGC 253 is kinematically complex with multiple velocity components. We constrain the density of the thermal gas to (1.4-4) x 10{sup 4} cm{sup -3} and estimate an ionizing photon flux of 1 x 10{sup 53} s{sup -1}. We use the RRL kinematics and the derived ionizing photon flux to show that the nuclear region of NGC 253 is not gravitationally bound, which is consistent with the outflow of gas inferred from the X-ray and H{alpha} measurements. The line profiles, fluxes, and kinematics of the H58{alpha} and H59{alpha} lines agree with those of RRLs at different frequencies confirming the accuracy of the previous, more difficult, high-frequency observations. We find that the EVLA is an order of magnitude more efficient for extragalactic RRL observations than the Very Large Array. These observations demonstrate both the power of the EVLA and the future potential of extragalactic RRL studies with the EVLA.

79 ASTRONOMY AND ASTROPHYSICS↗