Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “minimum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Bolus-dependent dosimetric effect of positioning errors for tangential scalp radiotherapy with helical tomotherapy

The dosimetric effect of errors in patient position is studied on-phantom as a function of simulated bolus thickness to assess the need for bolus utilization in scalp radiotherapy with tomotherapy. A treatment plan is generated on a cylindrical phantom, mimicking a radiotherapy technique for the scalp utilizing primarily tangential beamlets. A planning target volume with embedded scalplike clinical target volumes (CTVs) is planned to a uniform dose of 200 cGy. Translational errors in phantom position are introduced in 1-mm increments and dose is recomputed from the original sinogram. For each error the maximum dose, minimum dose, clinical target dose homogeneity index (HI), and dose-volume histogram (DVH) are presented for simulated bolus thicknesses from 0 to 10 mm. Baseline HI values for all bolus thicknesses were in the 5.5 to 7.0 range, increasing to a maximum of 18.0 to 30.5 for the largest positioning errors when 0 to 2 mm of bolus is used. Utilizing 5 mm of bolus resulted in a maximum HI value of 9.5 for the largest positioning errors. Using 0 to 2 mm of bolus resulted in minimum and maximum dose values of 85% to 94% and 118% to 125% of the prescription dose, respectively. When using 5 mm of bolus these values were 98.5% and 109.5%. DVHs showed minimal changes in CTV dose coverage when using 5 mm of bolus, even for the largest positioning errors. CTV dose homogeneity becomes increasingly sensitive to errors in patient position as bolus thickness decreases when treating the scalp with primarily tangential beamlets. Performing a radial expansion of the scalp CTV into 5 mm of bolus material minimizes dosimetric sensitivity to errors in patient position as large as 5 mm and is therefore recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric evaluation of integrated IMRT treatment of the chest wall and supraclavicular region for breast cancer after modified radical mastectomy

To investigate the dosimetric characteristics of irradiation of the chest wall and supraclavicular region as an integrated volume with intensity-modulated radiation therapy (IMRT) after modified radical mastectomy. This study included 246 patients who received modified radical mastectomy. The patients were scanned with computed tomography, and the chest wall (with or without the internal mammary lymph nodes) and supraclavicular region were delineated. For 143 patients, the chest wall and supraclavicular region were combined as an integrated planning volume and treated with IMRT. For 103 patients, conventional treatments were employed with 2 tangential fields for the chest wall, abutting a mixed field of 6-MV x-rays (16 Gy) and 9-MeV electrons (34 Gy) for the upper supraclavicular region. The common prescription dose was 50 Gy/25 Fx/5 W to 90% of the target volume. The dosimetric characteristics of the chest wall, the supraclavicular region, and normal organs were compared. For the chest wall target, compared with conventional treatments, the integrated IMRT plans lowered the maximum dose, increased the minimum dose, and resulted in better conformity and uniformity of the target volume. There was an increase in minimum, average, and 95% prescription dose for the integrated IMRT plans in the supraclavicular region, and conformity and uniformity were improved. The V{sub 30} of the ipsilateral lung and V{sub 10}, V{sub 30}, and mean dose of the heart on the integrated IMRT plans were lower than those of the conventional plans. The V{sub 5} and V{sub 10} of the ipsilateral lung and V{sub 5} of the heart were higher on the integrated IMRT plans (p < 0.05) than on conventional plans. Without an increase in the radiation dose to organs at risk, the integrated IMRT treatment plans improved the dose distribution of the supraclavicular region and showed better dose conformity and uniformity of the integrated target volume of the chest wall and supraclavicular region.

61 RADIATION PROTECTION AND DOSIMETRY↗

Intensity-modulated radiation therapy for pancreatic and prostate cancer using pulsed low–dose rate delivery techniques

Reirradiation of patients who were previously treated with radiotherapy is vastly challenging. Pulsed low–dose rate (PLDR) external beam radiotherapy has the potential to reduce normal tissue toxicities while providing significant tumor control for recurrent cancers. This work investigates treatment planning techniques for intensity-modulated radiation therapy (IMRT)-based PLDR treatment of various sites, including cases with pancreatic and prostate cancer. A total of 20 patients with clinical recurrence were selected for this study, including 10 cases with pancreatic cancer and 10 with prostate cancer. Large variations in the target volume were included to test the ability of IMRT using the existing treatment planning system and optimization algorithm to deliver uniform doses in individual gantry angles/fields for PLDR treatments. Treatment plans were generated with 10 gantry angles using the step-and-shoot IMRT delivery technique, which can be delivered in 3-minute intervals to achieve an effective low dose rate of 6.7 cGy/min. Instead of dose constraints on critical structures, ring structures were mainly used in PLDR-IMRT optimization. In this study, the PLDR-IMRT plans were compared with the PLDR-3-dimensional conformal radiation therapy (3DCRT) plans and the PLDR-RapidArc plans. For the 10 cases with pancreatic cancer that were investigated, the mean planning target volume (PTV) dose for each gantry angle in the PLDR-IMRT plans ranged from 17.6 to 22.4 cGy. The maximum doses ranged between 22.9 and 34.8 cGy. The minimum doses ranged from 8.2 to 17.5 cGy. For the 10 cases with prostate cancer that were investigated, the mean PTV doses for individual gantry angles ranged from 18.8 to 22.6 cGy. The maximum doses per gantry angle were between 24.0 and 34.7 cGy. The minimum doses per gantry angle ranged from 4.4 to 17.4 cGy. A significant reduction in the organ at risk (OAR) dose was observed with the PLDR-IMRT plan when compared with that using the PLDR-3DCRT plan. The volume receiving an 18-Gy (V{sub 18}) dose for the left and right kidneys was reduced by 10.6% and 12.5%, respectively, for the pancreatic plans. The volume receiving a 45-Gy (V{sub 45}) dose for the small bowel decreased from 65.3% to 45.5%. For the cases with prostate cancer, the volume receiving a 40-Gy (V{sub 40}) dose for the bladder and the rectum was reduced significantly by 25.1% and 51.2%, respectively. When compared with the RapidArc technique, the volume receiving a 30-Gy (V{sub 30}) dose for the left and the right kidneys was lower in the IMRT plans. For most OARs, no significant differences were observed between the PLDR-IMRT and the PLDR-RapidArc plans. These results clearly demonstrated that the PLDR-IMRT plan was suitable for PLDR pancreatic and prostate cancer treatments in terms of the overall plan quality. A significant reduction in the OAR dose was achieved with the PLDR-IMRT plan when compared with that using the PLDR-3DCRT plan. For most OARs, no significant differences were observed between the PLDR-IMRT and the PLDR-RapidArc plans. When compared with the PLDR-3DCRT plan, the PLDR-IMRT plan could provide superior target coverage and normal tissue sparing for PLDR reirradiation of recurrent pancreatic and prostate cancers. The PLDR-IMRT plan is an effective treatment choice for recurrent cancers in most cancer centers.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric comparison of intensity-modulated solutions for intact prostate cancer

The purpose of this study is intended to investigate the implementation of a modified class solution for intact prostate intensity-modulated radiation therapy (IMRT). The class solution uses 2 additional optimization structures intended to increase target conformity and decrease unnecessary dose to healthy tissue. A total of 10 randomly selected intact prostate IMRT patients were chosen for this retrospective study. Each of the original IMRT plans was compared with a modified class solution. The class solution implemented 2 additional optimization structures. The 95{sub O}PT was intended to increase target conformity, and the Avoidance{sub 3}780 was intended to reduce normal tissue. Each plan was evaluated for minimum, maximum, and mean doses to the target. Additionally, mean normal tissue dose, total monitor units (MUs), and segments were investigated. Conformity index and normal healthy index were also compared. All comparisons were evaluated using a paired t-test using GraphPad software. Evaluations of MUs; segments; minimum, maximum, mean target doses; mean normal tissue dose; and conformity index did not demonstrate a significant difference between the modified class solution and the original plans. However, evaluation of healthy tissue conformity index indicated a significant difference. Overall, 70% of the original plans failed to demonstrate a satisfactory score (< 0.6) of properly sparing normal healthy tissue, whereas 70% of the modified plans exhibited a satisfactory score (> 0.6). Most (90%) of the modified plans demonstrated a greater number of segments than the compared original plan. A modified class solution provides a good starting point for planning intact prostate cancer. The addition of the Avoidance{sub 3}780 structure increases the healthy tissue conformity index score.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric comparison of two arc-based stereotactic body radiotherapy techniques for early-stage lung cancer

To compare the dosimetric and delivery characteristics of two arc-based stereotactic body radiotherapy (SBRT) techniques for early-stage lung cancer treatment. SBRT treatment plans for lung tumors of different sizes and locations were designed using a single-isocenter multisegment dynamic conformal arc technique (SiMs-arc) and a volumetric modulated arc therapy technique (RapidArc) for 5 representative patients treated previously with lung SBRT. The SiMs-arc plans were generated with the isocenter located in the geometric center of patient's axial plane (which allows for collision-free gantry rotation around the patient) and 6 contiguous 60° arc segments spanning from 1° to 359°. 2 RapidArc plans, one using the same arc geometry as the SiMs-arc and the other using typical partial arcs (210°) with the isocenter inside planning target volume (PTV), were generated for each corresponding SiMs-arc plan. All plans were generated using the Varian Eclipse treatment planning system (V10.0) and were normalized with PTV V{sub 100} to 95%. PTV coverage, dose to organs at risk, and total monitor units (MUs) were then compared and analyzed. For PTV coverage, the RapidArc plans generally produced higher PTV D{sub 99} (by 1.0% to 3.3%) and higher minimum dose (by 2.7% to 12.7%), better PTV conformality index (by 1% to 8%), and less volume of 50% dose outside 2 cm from PTV (by 0 to 20.8 cm{sup 3}) than the corresponding SiMs-arc plans. For normal tissues, no significant dose differences were observed for the lungs, trachea, chest wall, and heart; RapidArc using partial arcs produced lowest maximum dose to spinal cord. For dose delivery, the RapidArc plans typically required 50% to 90% more MUs than SiMs-arc plans to deliver the same prescribed dose. The additional intensity modulation afforded by variable gantry speed and dose rate and by overlapping arcs enabled RapidArc plans to produce dosimetrically improved plans for lung SBRT, but required more MUs (by a factor > 1.5) to deliver. The dosimetric improvements, most notably in PTV minimum dose and in dose conformality for irregularly shaped PTVs, may outweigh the increased MUs in using RapidArc. For small and peripherally located tumors, SiMs-arc produces comparable dosimetric quality and could be more efficient in both treatment planning and dose delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

Linac-based extracranial radiosurgery with Elekta volumetric modulated arc therapy and an anatomy-based treatment planning system: Feasibility and initial experience

We reported our initial experience in using Elekta volumetric modulated arc therapy (VMAT) and an anatomy-based treatment planning system (TPS) for single high-dose radiosurgery (SRS-VMAT) of liver metastases. This study included a cohort of 12 patients treated with a 26-Gy single fraction. Single-arc VMAT plans were generated with Ergo++ TPS. The prescription isodose surface (IDS) was selected to fulfill the 2 following criteria: 95% of planning target volume (PTV) reached 100% of the prescription dose and 99% of PTV reached a minimum of 90% of prescription dose. A 1-mm multileaf collimator (MLC) block margin was added around the PTV. For a comparison of dose distributions with literature data, several conformity indexes (conformity index [CI], conformation number [CN], and gradient index [GI]) were calculated. Treatment efficiency and pretreatment dosimetric verification were assessed. Early clinical data were also reported. Our results reported that target and organ-at-risk objectives were met for all patients. Mean and maximum doses to PTVs were on average 112.9% and 121.5% of prescribed dose, respectively. A very high degree of dose conformity was obtained, with CI, CN, and GI average values equal to 1.29, 0.80, and 3.63, respectively. The beam-on-time was on average 9.3 minutes, i.e., 0.36 min/Gy. The mean number of monitor units was 3162, i.e., 121.6 MU/Gy. Pretreatment verification (3%-3 mm) showed an optimal agreement with calculated values; mean γ value was 0.27 and 98.2% of measured points resulted with γ < 1. With a median follow-up of 16 months complete response was observed in 12/14 (86%) lesions; partial response was observed in 2/14 (14%) lesions. No radiation-induced liver disease (RILD) was observed in any patients as well no duodenal ulceration or esophagitis or gastric hemorrhage. In conclusion, this analysis demonstrated the feasibility and the appropriateness of high-dose single-fraction SRS-VMAT in liver metastases performed with Elekta VMAT and Ergo++ TPS. Preliminary clinical outcomes showed a high rate of local control and minimum incidence of acute toxicity.

61 RADIATION PROTECTION AND DOSIMETRY↗

Method of predicting the mean lung dose based on a patient's anatomy and dose-volume histograms

The aim of this study was to propose a method to predict the minimum achievable mean lung dose (MLD) and corresponding dosimetric parameters for organs-at-risk (OAR) based on individual patient anatomy. For each patient, the dose for 36 equidistant individual multileaf collimator shaped fields in the treatment planning system (TPS) was calculated. Based on these dose matrices, the MLD for each patient was predicted by the homemade DosePredictor software in which the solution of linear equations was implemented. The software prediction results were validated based on 3D conformal radiotherapy (3D-CRT) and volumetric modulated arc therapy (VMAT) plans previously prepared for 16 patients with stage III non–small-cell lung cancer (NSCLC). For each patient, dosimetric parameters derived from plans and the results calculated by DosePredictor were compared. The MLD, the maximum dose to the spinal cord (D{sub max} {sub cord}) and the mean esophageal dose (MED) were analyzed. There was a strong correlation between the MLD calculated by the DosePredictor and those obtained in treatment plans regardless of the technique used. The correlation coefficient was 0.96 for both 3D-CRT and VMAT techniques. In a similar manner, MED correlations of 0.98 and 0.96 were obtained for 3D-CRT and VMAT plans, respectively. The maximum dose to the spinal cord was not predicted very well. The correlation coefficient was 0.30 and 0.61 for 3D-CRT and VMAT, respectively. The presented method allows us to predict the minimum MLD and corresponding dosimetric parameters to OARs without the necessity of plan preparation. The method can serve as a guide during the treatment planning process, for example, as initial constraints in VMAT optimization. It allows the probability of lung pneumonitis to be predicted.

61 RADIATION PROTECTION AND DOSIMETRY↗

AAA and AXB algorithms for the treatment of nasopharyngeal carcinoma using IMRT and RapidArc techniques

The aim of this study is to evaluate the impact of anisotropic analytical algorithm (AAA) and 2 reporting systems (AXB-D{sub m} and AXB-D{sub w}) of Acuros XB algorithm (AXB) on clinical plans of nasopharyngeal patients using intensity-modulated radiotherapy (IMRT) and RapidArc (RA) techniques. Six plans of different algorithm-technique combinations are performed for 10 patients to calculate dose-volume histogram (DVH) physical parameters for planning target volumes (PTVs) and organs at risk (OARs). The number of monitor units (MUs) and calculation time are also determined. Good coverage is reported for all algorithm-technique combination plans without exceeding the tolerance for OARs. Regardless of the algorithm, RA plans persistently reported higher D{sub 2%} values for PTV-70. All IMRT plans reported higher number of MUs (especially with AXB) than did RA plans. AAA-IMRT produced the minimum calculation time of all plans. Major differences between the investigated algorithm-technique combinations are reported only for the number of MUs and calculation time parameters. In terms of these 2 parameters, it is recommended to employ AXB in calculating RA plans and AAA in calculating IMRT plans to achieve minimum calculation times at reduced number of MUs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A continuum damage mechanics (CDM) based Wilshire model for creep deformation, damage, and rupture prediction

In this report, a new constitutive model is derived that combines the Wilshire equations with continuum damage mechanics (CDM) to enable the long-term prediction of creep deformation, damage, and rupture. The Wilshire equations have been demonstrated to accurately extrapolate the stress-rupture, minimum-creep-strain-rate, and time-to-strain of various alloys across decade of life. Recently, the time-to-creep-strain equation has been rearranged to predict creep deformation curves; however, the resulting equation is difficult to calibrate and does not track damage. The CDM-based Sinh constitutive model accurately predicts creep deformation, damage, and stress-rupture for a variety of alloys; however, it lacks an explicit description of stress and temperature co-dependence which limits interpolation and extrapolation ability. In this study, the Wilshire and the CDM-based Sinh equations are combined to create the “WCS” model. The WCS model combines the best features of each model while eliminating their deficiencies. Experimental data for alloy P91 is gathered and the WCS model is calibrated to the data. The WCS model accurately predicts the stress rupture, minimum-creep-strain-rate, creep deformation, and damage of alloy P91 across the experimental stress and temperature range as well as consistency in parametric simulations.

36 MATERIALS SCIENCE↗

Linking microstructure to creep behavior in vertically and horizontally built LPBF Haynes 282 compared with wrought material via θ -projection

Laser Powder Bed Fusion (LPBF) has emerged as a promising route for fabricating intricate geometries in high-performance alloys. Haynes 282 (H282) is a strong candidate for applications such as heat exchangers or engines due to its excellent creep strength and thermal stability; however, the long-term creep behavior of LPBF-processed H282 remains poorly understood. In this study, the θ -projection method is used to analyze and extrapolate the creep behavior of vertically built LPBF, horizontally built LPBF, compared to wrought H282 tested at 816 °C. Vertically built LPBF H282 exhibits the lowest minimum creep rate (MCR), while the horizontally built condition shows a higher MCR comparable to that of wrought H282. Despite these differences, both LPBF conditions exhibit significantly shorter rupture life and reduced rupture strain than the wrought material, with the most severe degradation observed in the horizontal builds, consistent with an earlier onset of tertiary creep and accelerated strain-rate evolution. Microstructural characterization reveals that both LPBF and wrought H282 exhibit abundant twin-related boundary character; however, their grain boundary topologies differ markedly. The wrought alloy contains a higher fraction of low-angle grain boundaries and continuous twin lamellae, whereas the LPBF microstructure is characterized by a suppressed low-angle boundary population and fragmented twin-related boundaries embedded within irregular high-angle grain boundary networks. Fractographic analysis further reveals predominantly intergranular cracking in LPBF H282, accompanied by grain-boundary-decorated carbides, Al 2 O 3 inclusions, and high-aspect-ratio pores. These results demonstrate that grain boundary topology, rather than minimum creep rate alone, plays a critical role in governing creep damage accumulation and rupture behavior in LPBF and wrought H282.

Creep↗

Charge collection in irradiated HV-CMOS detectors

Active silicon detectors built on p-type substrate are a promising technological solution for large area silicon trackers such as those at the High Luminosity LHC, but the radiation hardness of this novel approach has to be evaluated. Active n-in-p strip detector prototypes CHESS2 for ATLAS with different substrate resistivities in the range of 20-1000 Omega cm were irradiated with neutrons and protons up to a fluence of 2 x 10(15) n(eq) cm(-2) and 3.6 x 10(15) n(eq) cm(-2). Charge collection in passive test structures on the chip was evaluated using Edge-TCT and minimum ionising electrons from Sr-90. Results were used to assess radiation hardness of the detector in the given fluence range and to determine parameters of initial acceptor removal in different substrates.

active silicon detectors↗

The small-x gluon distribution in centrality biased pA and pp collisions

Here, the nuclear modification factor R pA (p T ) provides information on the small- x gluon distribution of a nucleus at hadron colliders. Several experiments have recently measured the nuclear modification factor not only in minimum bias but also for central pA collisions. In this paper we analyze the bias on the configurations of soft gluon fields introduced by a centrality selection via the number of hard particles. Such bias can be viewed as reweighting of configurations of small- x gluons. We find that the biased nuclear modification factor Q pA (p T ) for central collisions is above R pA (p T ) for minimum bias events, and that it may redevelop a “Cronin peak” even at small x . The magnitude of the peak is predicted to increase approximately like 1/A ⊥ ν , ν~0.6±0.1 , if one is able to select more compact configurations of the projectile proton where its gluons occupy a smaller transverse area A ⊥ . We predict an enhanced Q pp (p T )–1~1/(p T 2 ) ν and a Cronin peak even for central pp collisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Techno-economic and life-cycle analysis of strategies for improving operability and biomass quality in catalytic fast pyrolysis of forest residues

Many of the challenges faced by the first commercial biorefineries were associated with feedstock handling, quality, and cost. Strategies are needed to enable further expansion of biorefineries and meet the growing demand for bio-based fuels and products. Here, we examine 2 key feedstock challenges and mitigation strategies in the context of a catalytic fast pyrolysis (CFP) biorefinery: (1) the operability of the feed system, which may be improved by modifying the minimum particle size fed to the reactor, and (2) the quality of the biomass, which may be improved by employing air classification to remove undesirable material and increase fuel yields. We conduct techno-economic analysis (TEA) and life-cycle analysis for these strategies, employing a discrete event simulation model for biomass preprocessing combined with a series of correlations developed from literature data and a rigorous CFP conversion model. Our results highlight the importance of balancing increased cost and material losses from preprocessing against improved operability and fuel yields. Economics and sustainability were optimized when operating at the lowest minimum particle size, emphasizing the importance of minimizing material losses while maintaining the operability of the process. Economically, additional costs and material losses from air classification could be acceptable due to improved biomass conversion, and an optimum air classification speed was identified; however, the fuel GHG emissions were minimized when air classification was not used. Valorizing material removed during preprocessing as a coproduct could improve economics and sustainability, decreasing the burden of material losses.

09 - BIOMASS FUELS↗

Weighted Dynamic Time Warping for Time Series Classification

Dynamic time warping (DTW), which finds the minimum path by providing non-linear alignments between two time series, has been widely used as a distance measure for time series classification and clustering. However, DTW does not account for the relative importance regarding the phase difference between a reference point and a testing point. This may lead to misclassification especially in applications where the shape similarity between two sequences is a major consideration for an accurate recognition. Therefore, we propose a novel distance measure, called a weighted DTW (WDTW), which is a penalty-based DTW. Our approach penalizes points with higher phase difference between a reference point and a testing point in order to prevent minimum distance distortion caused by outliers. The rationale underlying the proposed distance measure is demonstrated with some illustrative examples. A new weight function, called the modified logistic weight function (MLWF), is also proposed to systematically assign weights as a function of the phase difference between a reference point and a testing point. By applying different weights to adjacent points, the proposed algorithm can enhance the detection of similarity between two time series. We show that some popular distance measures such as DTW and Euclidean distance are special cases of our proposed WDTW measure. We extend the proposed idea to other variants of DTW such as derivative dynamic time warping (DDTW) and propose the weighted version of DDTW. We have compared the performances of our proposed procedures with other popular approaches using public data sets available through the UCR Time Series Data Mining Archive for both time series classification and clustering problems. The experimental results indicate that the proposed approaches can achieve improved accuracy for time series classification and clustering problems.

99 GENERAL AND MISCELLANEOUS↗

Λ c + production in Pb–Pb collisions at s NN = 5.02 TeV

A measurement of the production of prompt $\Lambda^+_c$ baryons in Pb–Pb collisions at $\sqrt{s_{NN}} = 5.02$ TeV with the ALICE detector at the LHC is reported. The $\Lambda^+_c$ and $\Lambda^-_c$ were reconstructed at midrapidity ($\mid{y}\mid < 0.5$) via the hadronic decay channel $\Lambda^+_c$ $\rightarrow {pK^0_s}$ (and charge conjugate) in the transverse momentum and centrality intervals GeV/c and 0–80%. The ratio, which is sensitive to the charm quark hadronisation mechanisms in the medium, is measured and found to be larger than the ratio measured in minimum-bias pp collisions at TeV and in p–Pb collisions at TeV. In particular, the values in p–Pb and Pb–Pb collisions differ by about two standard deviations of the combined statistical and systematic uncertainties in the common interval covered by the measurements in the two collision systems. The ratio is also compared with model calculations including different implementations of charm quark hadronisation. The measured ratio is reproduced by models implementing a pure coalescence scenario, while adding a fragmentation contribution leads to an underestimation. The nuclear modification factor, , is also presented. The measured values of the of , and non-strange D mesons are compatible within the combined statistical and systematic uncertainties. They show, however, a hint of a hierarchy , conceivable with a contribution from coalescence mechanisms to charm hadron formation in the medium.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Femtoscopic study of the proton-proton and proton-deuteron systems in heavy-ion collisions at the LHC

This work reports femtoscopic correlations of p – – p ($\overline{p}$ – – $\overline{p}$) and p – – d ($\overline{p}$ – – $\overline{d}$) pairs measured in Pb–Pb collisions at center-of-mass energy per nucleon $\sqrt{s_{NN}}$ = 5.02 TeV in the ALICE Collaboration. A fit to the measured proton-proton correlation functions allows one to extract the dependence of the nucleon femtoscopic radius of the particle-emitting source on the pair transverse mass (m T ) and on the average charge particle multiplicity $\langle$dN ch /dη$\rangle$ 1/3 for three centrality intervals (0–10%, 10 – – 30 %, 30 – – 50 %). In both cases, the expected power-law and linear scalings are observed, respectively. The measured p–d correlations can be described by both two- and three-body calculations, indicating that the femtoscopy observable is not sensitive to the short-distance features of the dynamics of the p-(p-n) system, due to the large inter-particle distances in Pb–Pb collisions at the LHC. Indeed, in this study, the minimum measured femtoscopic source sizes for protons and deuterons have a minimum value at 2.73$^{+0.05}_{–0.05}$ and 3.10$^{+1.04}_{–0.86}$ fm, respectively, for the 30–50% centrality collisions. Moreover, the m T -scaling obtained for the p–p and p–d systems is compatible within 1σ of the uncertainties. These findings provide new input for fundamental studies on the production of light (anti)nuclei under extreme conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The effect of riser end geometry on gas-solid hydrodynamics in a CFB riser operating in the core annular and dilute homogeneous flow regimes

Riser hydrodynamics are a function of the flow rates of gas and solids as well as the exit geometry, particularly when operated above the upper transport velocity. This work compares the exit voidage for multiple geometries and two different solids: Geldart group A glass beads and Geldart group B coke. Geometries were changed by modifying the volume of an abrupt T-shaped exit above the lateral riser exit. This was accomplished by positioning a plunger at various heights above the exit from zero to 0.38 m. A dimensionless expression used to predict smooth exit voidage was modified to account for the effect of the depth of the blind-T. The new correlation contains the solids-gas load ratio, solids-to-gas density ratio, bed-to-particle diameter ratio, gas Reynolds Number, as well as a term for the exit geometry. This study also found that there was a minimum riser roof height above the blind-T exit beyond which the riser exit voidage was not affected by the exit geometry. A correlation for this minimum riser roof height has also been developed in this study. This study covered riser superficial gas velocities of 4.35 to 7.7 m/s and solids circulation rates of 1.3 to 11.5 kg/s.

01 COAL, LIGNITE, AND PEAT↗

Predicting the performance uncertainty of a 1-MW pilot-scale carbon capture system after hierarchical laboratory-scale calibration and validation

A challenging problem in designing pilot-scale carbon capture systems is to predict, with uncertainty, the adsorber performance and capture efficiency under various operating conditions where no direct experimental data exist. Motivated by this challenge, we previously proposed a hierarchical framework in which relevant parameters of physical models were sequentially calibrated from different laboratory-scale carbon capture unit (C2U) experiments. Specifically, three models of increasing complexity were identified based on the fundamental physical and chemical processes of the sorbent-based carbon capture technology. Results from the corresponding laboratory experiments were used to statistically calibrate the physical model parameters while quantifying some of their inherent uncertainty. The parameter distributions obtained from laboratory-scale C2U calibration runs are used in this study to facilitate prediction at a larger scale where no corresponding experimental results are available. In this paper, we first describe the multiphase reactive flow model for a sorbent-based 1-MW carbon capture system then analyze results from an ensemble of simulations with the upscaled model. The simulation results are used to quantify uncertainty regarding the design’s predicted efficiency in carbon capture. In particular, we determine the minimum gas flow rate necessary to achieve 90% capture efficiency with 95% confidence.

bubbling bed↗