Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurement data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Three-dimensional coherent Bragg imaging of spontaneously rotating nanoparticles

This dataset contains spontaneous rocking curves of individual 60 nm gold particles, measured as CDI patterns in the Bragg geometry. The dataset provides a higher-quality alternative to ID 151, and is collected at lower energy, shorter detector distance (~120 mm) and using a He-filled flight tube. Additionally, this data includes measurements along the (111), (200), and (220) directions, providing access to multiple strain directions.

60 nm truncated-octrahedral gold nanoparticles↗

Radiometric Testing of Germicidal UV Products, Round 2: Upper-Room Luminaires (CALiPER Report)

This report analyzes the independently tested performance of eight germicidal ultraviolet (GUV) upper-room luminaires marketed for use in occupied spaces and purchased between March and June 2023. This type of product is mounted to upper walls or ceilings to treat air in the portion of the room above occupants; this allows for safe use of the room when the device is operating, but requires sufficient air mixing between upper and lower portions of the room. Three of the luminaires used UV-emitting LEDs, and the remaining five luminaires used low-pressure mercury (LPM) lamps. Product testing covered radiometric and electrical performance for each luminaire. Initial performance was measured for all eight products, and four were additionally measured after 100 h and 500 h of operation. Measured performance data allowed for comparison against manufacturer or vendor claims if the tested products included such claims. Some products had no performance data available for a given quantity (e.g., UV-C output power), and only four of the eight luminaires had radiant intensity distribution data files in a standard format (e.g., IES LM-63) available for download from product websites. The lack of publicly available performance data makes it difficult for potential buyers and specifiers to identify suitable products and design GUV systems for their specific applications. When products had performance claims, they were sometimes contradictory (e.g., unexplained differences between multiple power values) or ambiguous (e.g., measurement units conflict with quantity, unclear whether luminaire power or lamp power, unclear whether UV output power or UV-C output power). Three of the eight tested luminaires had claimed output power (i.e., radiant flux) values that exceeded measured values by more than an order of magnitude. There was substantial variation in UV-C radiant efficiency, with a measured range of 0.3–1.9% for LED and 0.4–2.1% for LPM, as shown in Figure 1. For example, the LPM luminaire with 0.4% radiant efficiency would need 5 times the amount of electrical energy used by the LPM luminaire with 2.1% radiant efficiency to produce the same amount of UV-C output power. LPM luminaires that had parabolic reflectors aligned with inclined louvers exhibited substantially higher UV-C radiant efficiency than tested luminaires with other designs, potentially cutting energy use by 75%. These results indicate a substantial opportunity for more energy efficient LPM luminaire designs, while demonstrating that UV LED luminaires can offer comparable UV-C radiant efficiency in this application. This may seem surprising, given that LED emitters have lower UV-C radiant efficiency than LPM lamps, but the efficiency-throttling louvers that are generally required for LPM luminaires typically are not needed for LEDs thanks to their directionality. However, lateral beam angles (which describe beam width as viewed from above) were 41–83° for LED luminaires versus 89–110° for LPM luminaires. More luminaires may be required if their lateral beam angles are relatively small, and coverage may be poor if UV-C radiant intensity distribution (i.e., beam shape) is not considered when designing systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sedimentary Geothermal Resources in Nevada, Utah, Colorado, and Texas

The objectives of this project were to (1) perform a literature review of sedimentary geothermal resources, (2) identify data sources and develop data-collection methodologies that characterize selected resources, (3) screen sedimentary basins and formations for sedimentary geothermal potential, and (4) evaluate the technical feasibility of one or more selected locations. Numerous publications have characterized geothermal resources within sedimentary basins. A literature search reviewed publications describing resources located in Colorado, Louisiana, Nevada, Texas, Utah, and Wyoming. The most attractive resources have high temperature gradients, low drilling costs, and reservoir permeabilities greater than 10 millidarcies (mD). Prospects in Colorado, Nevada, Texas, and Utah exhibit attractive characteristics and were chosen for further analysis. Sedimentary resources in Nevada and Utah are most attractive, followed by tested resources in Texas and untested resources in Colorado. The identified resources in Wyoming and Louisiana had lower geothermal gradients and were not evaluated. Reservoir modeling and techno-economic analysis were performed at Marys River Basin–North in Nevada. Geothermal energy production at this location is expected to have a levelized cost of energy (LCOE) ranging between 10 and 20 cents/kWh. Additional work may result in lower LCOE estimates at this location and at other attractive prospects in these three regions. The Great Basin carbonate and alluvial aquifer system of eastern Nevada and western Utah includes a lower carbonate aquifer unit, which has the potential for hosting both conduction- and convection-dominated geothermal systems. Mapping has identified lateral thickness variability expressed as a roughly 120–150-km-wide central corridor, which hosts the thickest and most continuous formations and extends from near Las Vegas north to the Idaho border. Purchase and analysis of privately held legacy seismic data could potentially compensate for the lack of sufficient data documenting measured depth to the lower carbonate aquifer unit. Multiple orogenies, extension episodes, and intrusive events have deformed and displaced the target formations of the lower carbonate aquifer unit. This structural complexity and potential for dipping reservoirs emphasizes the need for detailed geological, geophysical, and reservoir modeling. Heat flow within three Colorado sedimentary basins reviewed as part of this study was calculated in targeted studies by the Colorado Geologic Survey and Colorado School of Mines. These calculations are based on bottom-hole temperature data sets with significant limitations and some variability but produce values consistently higher than the global continental average of 65 mW/m2 for all three basins. Heat flow in the Raton Basin is the highest; however, permeability measurements from specific sedimentary formations with high heat flow have not been obtained. Promising formations for sedimentary geothermal systems were found in all three regions studied—Nevada-Utah, Colorado, and Texas. The next steps for developing sedimentary geothermal resources vary due to differences in available data and resource uncertainties. Additional scopes of work are recommended for identified basins in these three regions.

15 GEOTHERMAL ENERGY↗

Multi-strain analysis of Pseudomonas putida reveals the metabolic and genetic diversity of the species

Pseudomonas putida is a gram-negative bacterial species increasingly utilized in biotechnology due to its robust growth, ability to degrade aromatic compounds, solvent tolerance, and genetic tractability. In this study, we report a comprehensive multi-strain analysis of 164 P. putida strains based on the reconstruction of a pan-putida metabolic network and the formulation of strain-specific genome-scale metabolic models (GEMs). We performed whole-genome sequencing and hybrid assembly for 40 strains, contributing a ~8% increase to the available genomic data for P. putida . Furthermore, high-throughput phenotypic profiling using the Biolog phenotype microarray system for 24 strains on 190 unique carbon sources, along with 15 aromatic compounds not present on Biolog plates, yielded 4,920 unique strain-phenotype measurements. These data were leveraged to curate GEMs for 24 representative strains, including a refined model for strain KT2440, which comprised 1,480 genes and 2,191 metabolites, achieving a prediction accuracy of 91.2% in carbon utilization. Systematic comparison of genomes and GEMs revealed both conserved core pathways and significant allelic and functional divergence across strains, highlighting strain-specific variation in aromatic degradation. While pathways for protocatechuate and phenylacetate degradation were widely conserved, metabolic capabilities for compounds such as ferulate, phenol, and cresols varied markedly, suggesting adaptation to distinct ecological niches. Alleleome analysis of enzymes, such as PcaI and PcaJ, revealed distinct, functionally similar clades, indicating possible convergent evolution or horizontal gene transfer. These results provide computable resources and informative models for selecting P. putida strains with desired traits for biomanufacturing and bioremediation and offer insights into the evolution and phylogeny of the P. putida species.

aromatics utilization↗

Measurement of charged hadron multiplicity in Au + Au collisions at $\sqrt{s_{NN}}$ = 200 GeV with the sPHENIX detector

The pseudorapidity distribution of charged hadrons produced in Au + Au collisions at a center-of-mass energy of $\sqrt{s_{NN}}$ = 200 GeV is measured using data collected by the sPHENIX detector. Charged hadron yields are extracted by counting cluster pairs in the inner and outer layers of the Intermediate Silicon Tracker, with corrections applied for detector acceptance, reconstruction efficiency, combinatorial pairs, and contributions from secondary decays. The measured distributions cover |η| < 1.1 across various centralities, and the average pseudorapidity density of charged hadrons at mid-rapidity is compared to predictions from Monte Carlo heavy-ion event generators. This result, featuring full azimuthal coverage at mid-rapidity, is consistent with previous experimental measurements at the Relativistic Heavy Ion Collider, thereby supporting the broader sPHENIX physics program.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

AGC-4 Specimen Post-Irradiation Examination Data Interim Report

This interim report documents preliminary results of the post-irradiation examination material property testing from the fourth advanced graphite creep (AGC), AGC 4, capsule specimens. This is the fourth of a series of six irradiation test trains planned as part of the AGC experiment to fully characterize the neutron irradiation effects and radiation creep behavior of current nuclear graphite grades to moderate dose levels (=7 dpa). The AGC 4 capsule was irradiated in the Idaho National Laboratory Advanced Test Reactor at a nominal temperature of 800°C and to a peak dose of 8 dpa. Half of the AGC-4 specimens were subjected to compressive stresses to induce irradiation creep. Post-irradiation testing and measurement results are reported with the exception of thermal testing, which is still in progress, and irradiation mechanical strength testing. Additionally, some specimens initially deemed too hot to be examined in the ART Graphite laboratory may still be measured. The data reported includes specimen dimensions for both stressed and unstressed specimens to establish the irradiation creep rates, mass and dimensional data necessary to derive density, elastic constants (Young?s modulus, shear modulus, and Poisson?s ratio) from ultrasonic time of flight velocity measurements, Young?s modulus from the fundamental frequency of vibration, and electrical resistivity. A more complete evaluation of trends in the material property changes, as well as irradiation-induced creep due to the irradiation environment and applied load on the specimens, will be discussed later in AGC 4 post-irradiation examination analysis reports.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGC-4 Specimen Post-Irradiation Examination Data Interim Report

This interim report documents preliminary results of the post-irradiation examination material property testing from the fourth advanced graphite creep (AGC), AGC 4, capsule specimens. This is the fourth of a series of six irradiation test trains planned as part of the AGC experiment to fully characterize the neutron irradiation effects and radiation creep behavior of current nuclear graphite grades to moderate dose levels (=7 dpa). The AGC 4 capsule was irradiated in the Idaho National Laboratory Advanced Test Reactor at a nominal temperature of 800°C and to a peak dose of 8 dpa. Half of the AGC-4 specimens were subjected to compressive stresses to induce irradiation creep. Post-irradiation testing and measurement results are reported with the exception of thermal testing, which is still in progress, and irradiation mechanical strength testing. Additionally, some specimens initially deemed too hot to be examined in the ART Graphite laboratory may still be measured. The data reported includes specimen dimensions for both stressed and unstressed specimens to establish the irradiation creep rates, mass and dimensional data necessary to derive density, elastic constants (Young?s modulus, shear modulus, and Poisson?s ratio) from ultrasonic time of flight velocity measurements, Young?s modulus from the fundamental frequency of vibration, and electrical resistivity. A more complete evaluation of trends in the material property changes, as well as irradiation-induced creep due to the irradiation environment and applied load on the specimens, will be discussed later in AGC 4 post-irradiation examination analysis reports.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Remote Radiation Sensing Using Aerial and Ground Platforms

Remote sensing of ionizing radiation has a significant role in waste management, nuclear material management and nonproliferation, and radiation safety. Robotic platforms can surpass the number of tasks that are achieved by humans. With this technique, the operator's radiation exposure can be decreased. Remote sensing allows for the evaluation and monitoring of radiological contamination. Gamma-ray and neutron sensors were integrated onto the robotic platforms. This approach allows for the radiation sensor data to be dynamically tracked and mapped thus enabling further analysis of the radiation flux in temporal and spatial domains. The goal is to complete scheduled tasks while the robot is being irradiated. To achieve this, electronic components must be shielded and radiation hardened. CZT Detector: Cadmium Zinc Telluride (CZT) detector technology has been a promising solution for gamma-ray and x-ray measurements. Detector data is transferred to the Odroid minicomputer that controls and powers the module via the USB. Robot Operating System (ROS) was utilized for data acquisition and data fusion. The Mariscotti method was employed for the spectrum analysis. A function was programmed in ROS for the automatic identification of photopeaks. CLYC Detector: A Cs{sub 2}LiYCl{sub 6}:Ce{sup 3+} (CLYC) detector was used for simultaneous medium-resolution gamma-ray measurements and neutron counting. A 2.54 cm diameter photomultiplier tube (PMT) was equipped with a high voltage supply and a miniature digitizer. Gamma-ray excitation: fast core-to-valence luminescence (CVL) with 1 ns decay constant, and prompt Ce{sup 3+} emission with 50 ns decay constant. Neutron excitation: slow cerium self-trapped excitation (Ce{sup 3+} STE), 1000 ns decay constant. Radiation Source Localization: Maximum Likelihood Estimation (MLE) and gradient-based methods were used to locate the position of a radiation source based on measured radiation intensities. Multi-Particle Transport Code FLUKA: Estimation of radiation damage of the electronic components is important in order to optimize the robot's operational time while it is irradiated. Displacement per atom (DPA) represents the radiation damage in materials exposed to the ionizing radiation. Various shielding layers of different thickness t were analyzed (< 5% statistical error). The model of the controller of the UAS was designed in FLUKA. Conclusion: CZT and CLYC detectors were integrated onto the robotic platforms. Radiation source localization and contour mapping using robotic platforms were studied. Functions for data analysis and fusion were developed in ROS. FLUKA code was utilized to analyze DPA values. Layers of low-density and high-density materials were used to shield the UAS electronics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CR-39 nuclear track detector response to inertial confinement fusion relevant ions

The detection properties of CR-39 were investigated for protons, deuterons, and tritons of various energies. Two models for the relationship between the track diameter and particle energy are presented and demonstrated to match experimental data for all three species. Data demonstrate that CR-39 has 100% efficiency for protons between 1 MeV and 4 MeV, deuterons between 1 MeV and 12.2 MeV, and tritons between 1 MeV and 10 MeV. The true upper bounds for deuterons and tritons exceed what could be measured in data. Simulations were developed to further explore the properties of CR-39 and suggest that the diameter–energy relationship of alpha particles cannot be captured by the conventional c-parameter model. These findings provide confidence in CR-39 track diameter based spectroscopy of all three species and provide invaluable insight for designing filtering for all CR-39 based diagnostics.

47 OTHER INSTRUMENTATION↗

X-ray multi-probe data acquisition: A novel technique for laser pump x-ray transient absorption spectroscopy

We report the development and implementation of a novel data acquisition (DAQ) technique for synchrotron-based laser pump X-ray Transient Absorption (XTA) spectroscopy, called X-ray Multi-Probe DAQ (XMP DAQ). This technique utilizes high performance analog to digital converters and home-built software to efficiently measure and process the XTA signal from all x-ray pulses between laser excitations. XMP DAQ generates a set of time resolved x-ray absorption spectra at thousands of different pump–probe time delays simultaneously. Two distinct XMP DAQ schemes are deployed to accommodate different synchrotron storage ring filling patterns. Current Integration (CI) DAQ is a quasi-analog technique that implements a fitting procedure to extract the time resolved absorption intensity from the averaged fluorescence detector response. The fitting procedure eliminates issues associated with small drifts in the voltage baseline and greatly enhances the accuracy of the technique. Photon Counting (PC) DAQ is a binary technique that uses a time resolved histogram to calculate the XTA spectrum. While PC DAQ is suited to measure XTA data with closely spaced x-ray pulses (~10 ns) and a low count rate (<1 detected photon/pulse), CI DAQ works best for widely spaced pulses (tens of ns or greater) with a high count rate (>1 detected photon/pulse). XMP DAQ produces a two-dimensional XTA dataset, enabling efficient quantitative analysis of photophysical and photochemical processes from the sub-nanosecond timescale to 100 μs and longer.

47 OTHER INSTRUMENTATION↗

Frequentist cosmological constraints from full-shape clustering measurements in DESI DR1

We present a frequentist analysis of clustering measurements from Data Release 1 of the Dark Energy Spectroscopic Instrument (DESI) using the standard profile likelihood method. While Bayesian inferences for effective field theory models of galaxy clustering can be highly sensitive to prior choices for extended cosmological models, frequentist inferences are not susceptible to such effects. We compare frequentist and Bayesian constraints for the parameter set {σ 8 , H 0 , Ω m , w 0 , w a } using the full-shape power spectrum multipoles, post-reconstruction baryon acoustic oscillation (BAO) measurements, and external datasets from the CMB and type Ia supernovae measurements. The frequentist confidence intervals are significantly shifted relative to the Bayesian credible intervals for the w 0 w a CDM model, unless supernovae data are included. When DESI full-shape and BAO data are fit jointly, we obtain the following 1σ frequentist confidence intervals for ΛCDM (w 0 w a CDM): σ 8 = 0.863 +0.048 -0.040 , H 0 = 68.96 +0.81 -0.80 km s -1 Mpc -1 , Ω m = 0.3034 ± 0.0110 (σ 8 = 0.782 +0.060 -0.036 , H 0 = 63.7 +4.2 -2.0 km s -1 Mpc -1 , Ω m = 0.378 +0.024 -0.047 , w 0 = -0.16 +0.10 -0.50 , w a = -3.0 +1.7 ), corresponding to 0.8σ, 0.3σ, 0.7σ (2.1σ, 4.1σ, 6.5σ, 6.3σ, 6.6σ) shifts between the maximum likelihood estimate and the Bayesian posterior mean for ΛCDM (w 0 w a CDM) respectively.

Bayesian reasoning↗

Air quality impacts from the development of unconventional oil and gas well pads: Air toxics and other volatile organic compounds

Unconventional oil and natural gas development (UOGD) has expanded rapidly across the United States in recent decades and raised concerns about associated air quality impacts. While significant effort has been made to quantify methane emissions, relatively few observations have been made of Volatile Organic Compounds (VOCs), especially during drilling and completion of new wells. Extensive air monitoring during development of several large, multi-well pads in Broomfield, Colorado, in the Denver-Julesburg Basin, provides a novel opportunity to examine changes in local air toxics and other VOC concentrations during well drilling and completions and production. These operations offer an especially useful case to study as several management practices were implemented to reduce emissions (e.g., electrified, grid-powered drill rigs and closed loop fluid handling systems to reduce truck traffic and limit fluid handling on the pad). With simultaneous measurements of methane and 50 VOCs from October 2018 to December 2022 at as many as 19 sites near well pads, in adjacent neighborhoods, and at a more distant reference location, we identify impacts from each phase of well development and production. Use of weekly, time-integrated canisters, a Proton Transfer Reaction Mass Spectrometer (PTR-MS), continuous photoionization detectors (PID) to trigger canister collection upon detection of VOC-rich plumes, and an instrumented vehicle, provided a powerful suite of measurements to characterize both transient plumes and longer-term changes in air quality. Prior to the start of well development, VOC gradients were small across Broomfield. Once drilling commenced, concentrations of oil and gas (O&G) related VOCs, including alkanes and aromatics, increased around active well pads. Concentration increases were clearly apparent during certain operations, including drilling, coil tubing/millout operations, and production tubing installation. Emissions of C 8 –C 10 n-alkanes during drilling operations highlighted the importance of VOC emissions from synthetic drilling mud chosen to reduce odor impacts. More than 90 samples were collected of transient plumes. Using composition measurements, meteorological data, and information about well pad activities, these plumes were connected with specific UOGD operations including drilling, flowback, and production equipment maintenance. The chemical signatures of these plumes differed by operation type (e.g., C 8 –C 10 n-alkanes constituted a larger fraction of measured VOCs in drilling-related plumes). Concentrations of individual, oil and gas-related VOCs in these plumes were often several orders of magnitude higher than in background air, with maximum ethane and benzene concentrations of 79,600 and 819 ppbv, respectively. Because these plumes typically impact a monitoring site for just several minutes, they are easily missed by slower-responding instruments. Study measurements highlight future emission mitigation opportunities during UOGD operations, including better control of emissions from shakers that separate drill cuttings from drilling mud, production separator maintenance operations, and periodic emptying of sand cans during flowback operations.

54 ENVIRONMENTAL SCIENCES↗

Plutonium Retention by Crystalline Silicotitanate under Hyperalkaline Conditions Relevant to Tank-Side Cesium-Removal at the Hanford Site

Crystalline silicotitanate (CST) is used in Hanford’s Tank-Side Cesium-Removal (TSCR) process to selectively remove Cs-137 from highly caustic, nitrate-rich tank supernatants. Recent testing with actual waste samples suggests that CST can also retain measurable plutonium (Pu), which could affect radiological classification and disposal pathways for spent CST. To quantify this behavior, Pu partitioning to CST was studied under Hanford-relevant conditions using batch-contact experiments in a representative simulant (2 M NaNO3, 0.7 M NaOH). Isotherm data were measured and distribution ratios calculated, with Cs+ uptake used as benchmark. Under low-carbonate conditions, Pu was retained strongly by CST in systems initially contacted with either PuO2 nanoparticles (Pu(IV)) or aqueous Pu(VI), with distribution ratios of ~2,200–3,700 mL/g, generally exceeding those for Cs+ (~400–1,000 mL/g). Increasing carbonate concentration strongly reduced PuO2 nanoparticle retention; at [Na2CO3] = 1 M, distribution ratios decreased by up to one order of magnitude to roughly 100–300 mL/g. Electron microscopy suggests that Pu retention involves a combination of mechanisms such as PuO2 NP aggregation induced by CST leachate components, and association with CST bead surfaces.

Neumann, J.↗

Physical Parameters of the Multiplanet Systems HD 106315 and GJ 9827

HD 106315 and GJ 9827 are two bright, nearby stars that host multiple super-Earths and sub-Neptunes discovered by K2 that are well suited for atmospheric characterization. We refined the planets’ ephemerides through Spitzer transits, enabling accurate transit prediction required for future atmospheric characterization through transmission spectroscopy. Through a multiyear high-cadence observing campaign with Keck/High Resolution Echelle Spectrometer and Magellan/Planet Finder Spectrograph, we improved the planets’ mass measurements in anticipation of Hubble Space Telescope transmission spectroscopy. For GJ 9827, we modeled activity-induced radial velocity signals with a Gaussian process informed by the Calcium II H&K lines in order to more accurately model the effect of stellar noise on our data. We measured planet masses of M {sub b} = 4.87 ± 0.37 M {sub ⊕}, M {sub c} = 1.92 ± 0.49 M {sub ⊕}, and M {sub d} = 3.42 ± 0.62 M {sub ⊕}. For HD 106315, we found that such activity radial velocity decorrelation was not effective due to the reduced presence of spots and speculate that this may extend to other hot stars as well (T {sub eff} > 6200 K). We measured planet masses of M {sub b} = 10.5 ± 3.1 M {sub ⊕} and M {sub c} = 12.0 ± 3.8 M {sub ⊕}. We investigated all of the planets’ compositions through comparison of their masses and radii to a range of interior models. GJ 9827 b and GJ 9827 c are both consistent with a 50/50 rock-iron composition, GJ 9827 d and HD 106315 b both require additional volatiles and are consistent with moderate amounts of water or hydrogen/helium, and HD 106315 c is consistent with a ∼10% hydrogen/helium envelope surrounding an Earth-like rock and iron core.

47 OTHER INSTRUMENTATION↗

Improved $^{95}\mathrm{Mo}$ neutron resonance parameters and astrophysical reaction rates

We report improved 95 Mo neutron resonance parameters and reaction rates are important for nuclear astrophysics, testing nuclear models, and nuclear criticality safety. However, despite many previous neutron-capture and total cross-section measurements on this nuclide, there still is much room for improvement as well as several discrepancies. For example, there are very few firm resonance spin and parity assignments; average resonance parameters are available only for each parity, the currently recommended astrophysical reaction rate results in disagreements between stellar models and meteoric isotopic anomalies, and there are substantial disagreements in the neutron-capture cross section at low energies important for nuclear criticality safety. To obtain an improved set of neutron resonance parameters and astrophysical reaction rates for 95 Mo. High-resolution neutron-capture and transmission data were measured at the Oak Ridge Electron Linear Accelerator (ORELA) using highly isotopically enriched 95 Mo samples. The neutron-capture apparatus, data reduction, and analysis were improved so that information contained in the γ-ray cascade following neutron capture were used to assign resonance J π values. Following this, simultaneous analysis of the new neutron-capture and transmission data was used to obtain resonance energies, gamma widths, and neutron widths and their uncertainties to a maximum energy of 10 keV. Accurate neutron-capture cross sections also were obtained for the unresolved resonance region to a maximum energy of 500 keV and, together with the new resonance parameters, used to calculate the astrophysical reaction rates in the temperature range from 5 to 30 keV. A vastly improved set of 95Mo neutron resonance parameters and an astrophysical reaction rate accurate to about 3% were obtained. Firm J π assignments were determined for 261 of the 314 observed resonances. This is a very large improvement over the previously published 32 firm J π assignments for 108 resonances. Also, the number of resonances having both firm J π assignments and Γ γ values was increased by almost a factor of 24—from 11 to 261. Neutron- and total-radiation-width distributions and average resonance spacings, average total radiation widths, and neutron strength functions were obtained for the six different s- and p-wave possibilities. Parameters for the lowest s-wave resonance, which is most important for criticality benchmarks, were obtained with high accuracy. Simple modification of the neutron-capture apparatus and expansion and improvement of data analysis techniques led to a large increase in firm J π assignments for 95 Mo neutron resonances. The resulting astrophysical reaction rate is 20%–30% larger than the currently recommended rate at s-process temperatures, which should lead to better agreement between stellar models and meteoric isotopic anomalies. The neutron-capture cross section at low energies is substantially larger than recommended in the latest evaluation, which is problematical for criticality benchmarks. The average resonance spacing as a function of spin and parity is significantly different from current models. The total-radiation-width distributions are significantly broader than predicted by theory and show significant departures from the expected Gaussian shapes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Smart thermostat data-driven U.S. residential occupancy schedules and development of a U.S. residential occupancy schedule simulator

Occupancy schedule is one of the key inputs in Building Energy Modeling (BEM) to reflect the interaction between buildings and occupants. Over the past decades, standardized occupancy schedules, developed mainly by engineering rule-of-thumb, have been widely used in BEM due to its simplicity and lack of real measured occupancy data. However, the BEM community has recognized their association with uncertainty and reliability in simulation results from BEM. This study introduces representative occupancy schedules in the U.S. residential buildings, derived from a large smart thermostat dataset and time-series K-means clustering, and an open-source tool to generate a stochastic residential occupancy schedule. Over 90,000 residential occupancy schedules were estimated from the ecobee Donate Your Data dataset. Then, the representative occupancy schedules were identified through clustering. This study further investigated the impacts of three parameters (day, house type, and state) on residential occupancy schedules. Then, a tool, the Residential Occupancy Schedule Simulator (ROSS), is developed using the representative occupancy schedules derived in this study. Details of this tool are presented in this paper. In conclusion, the derived representative occupancy schedules and the ROSS tool can help improve the energy modeling of residential buildings.

42 ENGINEERING↗

The mass profiles of dwarf galaxies from Dark Energy Survey lensing

We present a novel approach to extracting dwarf galaxies from photometric data to measure their average halo mass profile with weak lensing. We characterize their stellar mass and redshift distributions with a spectroscopic calibration sample. By combining the ${\sim} 5000\,\mathrm{deg}^2$ multiband photometry from the Dark Energy Survey and redshifts from the Satellites Around Galactic Analogs Survey with an unsupervised machine learning method, we select a low-mass galaxy sample spanning redshifts $z\lt 0.3$ and divide it into three mass bins. From low to high median mass, the bins contain [146 420, 330 146, 275 028] galaxies and have median stellar masses of $\log _{10}(M_*/\text{M}_\odot)=\left[8.52\substack{+0.57 -0.76},\, 9.02\substack{+0.50 -0.64},\, 9.49\substack{+0.50 -0.58}\right]$ . We measure the stacked excess surface mass density profiles, $\Delta \Sigma (R)$, of these galaxies using galaxy–galaxy lensing with a signal-to-noise ratio of [14, 23, 28]. Through a simulation-based forward-modelling approach, we fit the measurements to constrain the stellar-to-halo mass relation and find the median halo mass of these samples to be $\log _{10}(M_{\rm halo}/\text{M}_\odot)$ = [$10.67\substack{+0.2 -0.4}$, $11.01\substack{+0.14 -0.27}$, $11.40\substack{+0.08 -0.15}$]. The cold dark matter profiles are consistent with NFW (Navarro, Frenk, and White) profiles over scales ${\lesssim} 0.15 \, {h}^{-1}$ Mpc. We find that ${\sim} 20$ per cent of the dwarf galaxy sample are satellites. This is the first measurement of the halo profiles and masses of such a comprehensive, low-mass galaxy sample. The techniques presented here pave the way for extracting and analysing even lower mass dwarf galaxies and for more finely splitting galaxies by their properties with future photometric and spectroscopic survey data.

dark matter↗

Measurement of CP asymmetries and branching fraction ratios of B – decays to two charm mesons

The CP asymmetries of seven B – decays to two charm mesons are measured using data corresponding to an integrated luminosity of 9 fb –1 of proton-proton collisions collected by the LHCb experiment. Decays involving a D *0 or ${D}_s^{\ast -}$ meson are analysed by reconstructing only the D 0 or ${D}_s^{-}$ decay products. This paper presents the first measurement of $\mathcal{A}$ CP (B – → ${D}_s^{\ast -}$ D 0 ) and $\mathcal{A}$ CP (B – → ${D}_s^{-}$D $\ast$0 ), and the most precise measurement of the other five CP asymmetries. There is no evidence of CP violation in any of the analysed decays. Additionally, two ratios between branching fractions of selected decays are measured.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗