Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

The Evaluation of a Test Device for Human Occupant Restraint (THOR) Under Vertical Loading Conditions: Part 1 - Experimental Setup and Results

A series of 16 vertical tests were conducted on a Test Device for Human Occupant Restraint (THOR) - NT 50th percentile Anthropomorphic Test Device (ATD) at NASA Langley Research Center (LaRC). The purpose of the tests conducted at NASA LaRC was threefold. The first was to add vertical response data to the growing test database for THOR-NT development and validation. Second, the THOR-NT analytical computational models currently in development must be validated for the vertical loading environment. The computational models have been calibrated for frontal crash environments with concentration on accurately replicating head/neck, thoracic, and lower extremity responses. Finally, familiarity with the THOR ATD is necessary because NASA is interested in evaluating advanced ATDs for use in future flight and research projects. The THOR was subjected to vertical loading conditions ranging between 5 and 16 g in magnitude and 40 to 120 milliseconds (msec) in duration. It was also tested under conditions identical to previous tests conducted on the Hybrid II and III ATDs to allow comparisons to be made. Variations in the test setup were also introduced, such as the addition of a footrest in an attempt to offload some of the impact load into the legs. A full data set of the THOR-NT ATD will be presented and discussed. Results from the tests show that the THOR was largely insensitive to differences in the loading conditions, perhaps due in part to their small magnitudes. THOR responses, when compared to the Hybrid II and III in the lumbar region, demonstrated that the THOR more closely resembled the straight spine Hybrid setup. In the neck region, the THOR behaved more like the Hybrid III. However in both cases, the responses were not identical, indicating that the THOR would show differences in response than the Hybrid II and III ATDs when subjected to identical impact conditions. The addition of a footrest did not significantly affect the THOR response due to the nature of how the loading conditions were applied.

Littell, Justin D.↗

Breadboard CO2 and humidity control system

A regenerable CO2 and humidity control system is being developed for potential use on shuttle as an alternate to the baseline lithium hydroxide (LiOH)/condensing heat exchanger system. The system utilizes a sorbent material, designated HS-C, to adsorb CO2 and water vapor from the cabin atmosphere. The material is regenerated by exposing it to space vacuum. A half-size breadboard system, utilizing a flight representative HS-C canister, was designed, built, and performance tested to shuttle requirements for total CO2 and total humidity removal. The use of a new chemical matrix material allowed significant optimization of the system design by packing the HS-C chemical into the core of a heat exchanger which is manifolded to form two separate and distinct beds. Breadboard system performance was proven by parametric testing and simulated mission testing over the full range of shuttle crew sizes and metabolic loadings. Vacuum desorption testing demonstrated considerable savings in previously projected shuttle vacuum duct sizing.

Boehm, A. M.↗

Smoothly Adjustable dc Load

Load circuit for testing dc power supplies adjusted without momentary interruptions typical of rheostat loads. Load current passes through power transistor and fixed resistor instead of wire-wound rheostat. In new circuit potentiometer used to adjust bias of power transistor and thereby adjust load. Components are standard, commercially available parts, mounted on transistor heat sink, forming compact package.

Patocka, C. G.↗

Method Development for Experimental Characterization of Dynamic Strength of Aluminum Structures

Space Flight Hardware (SFH) experiences intense vibratory loading during flight, which only lasts a few minutes. When determining the appropriate size of these components to withstand such loading without becoming damaged (plastically deforming or breaking), standard design practice is to assume that the peak dynamic loads are applied statically. In doing so, the resulting stress is compared against a material strength parameter obtained from a quasi-static experiment. Since the near-peak stresses are only experienced over a small fraction of time in reality, this approach leads to design conservatism that unnecessarily increases structural mass as well as the associated inefficiency and financial cost. In an effort to modernize engineering design standards to appropriately consider the higher practical strength of dynamically loaded structures, this overarching research project seeks to develop an experimental test procedure for quantifying the dynamic strength of metallic alloys as a function of excitation frequency. In the ideal case, the characterization test would include an in-situ method for monitoring the onset and progression of plastic deformation of the test specimen undergoing vibratory loading. These new tests are designed to be high intensity (forcing amplitude), short term (60 seconds at full amplitude), and cyclic in nature (sinusoidal excitation via attached stinger to an otherwise cantilevered beam). In addition, the initial metallic alloy under investigation is 6061 aluminum, due to its wide use and applicability for SFH. Thus far, the most promising monitoring method under development with live-capacity is to track hysteresis behavior of the beam from power dissipation trends, calculated via force (from transducer on excitation stinger) and velocity (measurements from Laser Doppler Vibrometer) data and work to distinguish between elastic and plastic features. As a key component of this ongoing method development, any pseudo-live indication of plasticity can be corroborated against the outcome of a pre-post assessment of damage via macroscopic evaluation of beam geometry (i.e. assessing any permanent change in the beam’s tip deflection). Support for experimental design decisions as well as dynamic strength data from tests with excitation frequencies of 10, 40, and 55 Hz will be discussed. This work contributes to the foundation for a new type of vibration-based characterization experiments and generates initial data on the functional strength of 6061 aluminum under the conditions considered. Keywords: vibrations, plastic deformation, aluminum

vibrations↗

Method Development for Experimental Characterization of Dynamic Strength of Aluminum Structures

Space Flight Hardware (SFH) experiences intense vibratory loading during flight, which only lasts a few minutes. When determining the appropriate size of these components to withstand such loading without becoming damaged, standard design practice is to assume that the peak dynamic loads are applied statically. In doing so, the resulting stress is compared against a material strength parameter obtained from a quasi-static experiment. Since the near-peak stresses are only experienced over a small fraction of time in reality, this approach leads to design conservatism that unnecessarily increases structural mass as well as the associated inefficiency and financial cost. In an effort to modernize engineering design standards to appropriately consider the higher practical strength of dynamically loaded structures, this overarching research project seeks to develop an experimental test procedure for quantifying the dynamic strength of metallic alloys as a function of excitation frequency. In the ideal case, the characterization test would include an in-situ method for monitoring the onset and progression of plastic deformation of the test specimen undergoing vibratory loading. These new tests are designed to be high intensity (forcing amplitude), short term (60 seconds at full amplitude), and cyclic in nature (sinusoidal excitation via attached stinger to an otherwise cantilevered beam). In addition, the initial alloy under investigation is 6061 aluminum, due to its wide use and applicability for SFH. Thus far, the primary candidate under development with live-capacity is to track hysteresis behavior of the beam from power dissipation trends, calculated via force (from transducer on excitation stinger) and velocity (measurements from Laser Doppler Vibrometer) data and work to distinguish between elastic and plastic features. As a key component of this ongoing method development, any pseudo-live indication of plasticity could be corroborated against the outcome of a pre-post assessment of damage via macroscopic evaluation of beam geometry (i.e. assessing any permanent change in the beam’s tip deflection). Support for experimental design decisions as well as dynamic strength data from tests with excitation frequencies of 10, 40, and 55 Hz will be discussed. This work contributes to the foundation for a new type of vibration-based characterization experiments and generates initial data on the functional strength of 6061 aluminum under the conditions considered.

vibrations, plastic deformation, aluminum, testing↗

Ring Pull Strain Analysis

Ring Pull Strain Analysis (RPSA) is a framework for analysis of Digital Image Correlation (DIC) data of gaugeless ring pull testing. It is meant for analysis of rings cut from tube cross sections and pulled in a displacement-controlled tensile test. This code takes load frame data, images take during testing, and csv files from the DIC analysis of those images and allows the user to analyze and plot data from the test. Some important features of the software include getting the strain values as a function of radial distance and angle, plotting of the strain around the ring, and stress-strain analysis of the load frame data.

Beck, Peter↗

Ring Pull Strain Analysis

Ring Pull Strain Analysis (RPSA) is a framework for analysis of Digital Image Correlation (DIC) data of gaugeless ring pull testing. It is meant for analysis of rings cut from tube cross sections and pulled in a displacement-controlled tensile test. This code takes load frame data, images take during testing, and csv files from the DIC analysis of those images and allows the user to analyze and plot data from the test. Some important features of the software include getting the strain values as a function of radial distance and angle, plotting of the strain around the ring, and stress-strain analysis of the load frame data. Additional capability is included with Ring Pull Coating Analysis (RPCA, also part of the software). Additional images are taken of samples with an outer coating and are used to correlate failure of the coating with strain values measured with DIC.

Beck, Peter↗

Structural Benchmark Testing of Superalloy Lattice Block Subelements Completed

Superalloy lattice block panels, which are produced directly by investment casting, are composed of thin ligaments arranged in three-dimensional triangulated trusslike structures (see the preceding figure). Optionally, solid panel face sheets can be formed integrally during casting. In either form, lattice block panels can easily be produced with weights less than 25 percent of the mass of a solid panel. Inconel 718 (IN 718) and MarM-247 superalloy lattice block panels have been developed under NASA's Ultra-Efficient Engine Technology Project and Higher Operating Temperature Propulsion Components Project to take advantage of the superalloys' high strength and elevated temperature capability with the inherent light weight and high stiffness of the lattice architecture (ref. 1). These characteristics are important in the future development of turbine engine components. Casting quality and structural efficiency were evaluated experimentally using small beam specimens machined from the cast and heat treated 140- by 300- by 11-mm panels. The matrix of specimens included samples of each superalloy in both open-celled and single-face-sheet configurations, machined from longitudinal, transverse, and diagonal panel orientations. Thirty-five beam subelements were tested in Glenn's Life Prediction Branch's material test machine at room temperature and 650 C under both static (see the following photograph) and cyclic load conditions. Surprisingly, test results exceeded initial linear elastic analytical predictions. This was likely a result of the formation of plastic hinges and redundancies inherent in lattice block geometry, which was not considered in the finite element models. The value of a single face sheet was demonstrated by increased bending moment capacity, where the face sheet simultaneously increased the gross section modulus and braced the compression ligaments against early buckling as seen in open-cell specimens. Preexisting flaws in specimens were not a discriminator in flexural, shear, or stiffness measurements, again because of redundant load paths available in the lattice block structure. Early test results are available in references 2 and 3; more complete analyses are scheduled for publication in 2004.

Source record↗

GVIPS Prediction of Cyclic Ratchetting Behavior and Cycles With Interrupted Relaxation Periods of TIMETAL 21S at 650 oC

The predictive performance of a multimechanism GVIPS model with saturating hardening function is assessed against a set of high temperature cyclic experiments under both strain-control and stress-control at varying rates of loading as well as several complex interrupted cyclic responses. The material specimens were composed of the titanium alloy, TIMETAL 21S, and tested at 650oC, see Lissenden et al., 2007. The model did a very good job of predicting the variety of tests, particularly given the fact that only monotonic loading tests (tensile, creep, relaxation) and a single fully reversed cycle was used for characterization. It was particularly interesting that the model was capable of reasonably capturing the rate of accumulated strain during ratchetting under tensile mean stress. Given complex interrupted cyclic response, the model was able to both qualitatively and even quantitatively predict reasonably well both the cyclic and associated relaxation periods (in all quadrants of the stress-strain space) thus confirming the validity of the chosen functional forms for both hardening and thermal recovery. The quantitative inaccuracy is associated with the fact that the material specimens tested by Lissenden et al., 2007 was significantly “softer” than those tested by Castelli in Saleeb et al., 1994 which were used for characterization of the GVIPS model parameters.

Viscoplaticity↗

GVIPS Prediction of Cyclic Ratchetting Behavior and Cycles with Interrupted Relaxation Periods of TIMETAL 21S at 650 °C

The predictive performance of a multimechanism GVIPS model with saturating hardening function is assessed against a set of high temperature cyclic experiments under both strain-control and stress-control at varying rates of loading as well as several complex interrupted cyclic responses. The material specimens were composed of the titanium alloy, TIMETAL 21S, and tested at 650 °C, see Lissenden et al., 2007. The model did a very good job of predicting the variety of tests, particularly given the fact that only monotonic loading tests (tensile, creep, relaxation) and a single fully reversed cycle was used for characterization. It was particularly interesting that the model was capable of reasonably capturing the rate of accumulated strain during ratchetting under tensile mean stress. Given complex interrupted cyclic response, the model was able to both qualitatively and even quantitatively predict reasonably well both the cyclic and associated relaxation periods (in all quadrants of the stress-strain space) thus confirming the validity of the chosen functional forms for both hardening and thermal recovery. The quantitative inaccuracy is associated with the fact that the material specimens tested by Lissenden et al., 2007 was significantly “softer” than those tested by Castelli in Saleeb et al., 1994 which were used for characterization of the GVIPS model parameters.

Viscoplaticity↗

Ground/Flight Correlation of Aerodynamic Loads with Structural Response

Ground and flight tests provide a basis and methodology for in-flight characterization of the aerodynamic and structural performance through the monitoring of the fluid-structure interaction. The NF-15B flight tests of the Intelligent Flight Control System program provided a unique opportunity to test the correlation of aerodynamic loads with points of flow attaching and detaching from the surface, which are also known as flow bifurcation points, as observed in a previous wind tunnel test performed at the U.S. Air Force Academy (Colorado Springs, Colorado). Moreover, flight tests, along with the subsequent unsteady aerodynamic tests in the NASA Transonic Dynamics Tunnel (TDT), provide a basis using surface flow sensors as means of assessing the aeroelastic performance of flight vehicles. For the flight tests, the NF-15B tail was instrumented with hot-film sensors and strain gages for measuring root-bending strains. This data were gathered via selected sideslip maneuvers performed at level flight and subsonic speeds. The aerodynamic loads generated by the sideslip maneuver resulted in a structural response, which were then compared with the hot-film sensor signals. The hot-film sensor signals near the stagnation region were found to be highly correlated with the root-bending strains. For the TDT tests, a flexible wing section developed under the U.S. Air Force Research Lab SensorCraft program was instrumented with strain gages, accelerometers, and hot-film sensors at two span stations. The TDT tests confirmed the correlation between flow bifurcation points and the wing structural response to tunnel-generated gusts. Furthermore, as the wings structural modes were excited by the gusts, a gradual phase change between the flow bifurcation point and the structural mode occurred during a resonant condition.

Mangalam, Arun S.↗

Critical assessment of precracked specimen configuration and experimental test variables for stress corrosion testing of 7075-T6 aluminum alloy plate

A research program was conducted to critically assess the effects of precracked specimen configuration, stress intensity solutions, compliance relationships and other experimental test variables for stress corrosion testing of 7075-T6 aluminum alloy plate. Modified compact and double beam wedge-loaded specimens were tested and analyzed to determine the threshold stress intensity factor and stress corrosion crack growth rate. Stress intensity solutions and experimentally determined compliance relationships were developed and compared with other solutions available in the literature. Crack growth data suggests that more effective crack length measurement techniques are necessary to better characterize stress corrosion crack growth. Final load determined by specimen reloading and by compliance did not correlate well, and was considered a major source of interlaboratory variability. Test duration must be determined systematically, accounting for crack length measurement resolution, time for crack arrest, and experimental interferences. This work was conducted as part of a round robin program sponsored by ASTM committees G1.06 and E24.04 to develop a standard test method for stress corrosion testing using precracked specimens.

Domack, M. S.↗

Helicopter flight investigation to determine the effects of a closed-circuit TV on performance of a precision sling-load handling task

Helicopter sling-load operations have been limited during hover and low-speed flight by the degree of precision achieved by the pilot/helicopter/sling-load combination. Previous attempts to improve precision have included stabilization of the load and helicopter and the addition of a pilot station directly facing the load. In these tests, use of a closed-circuit TV as a display that would permit sling-load delivery and placement by the forward-facing pilot was evaluated using a CH-54B helicopter. In all, three test cases were documented, which included the following: (1) forward-facing pilot using the TV display, (2) forward-facing pilot using verbal commands from a load-facing observer, and (3) aft-facing pilot using direct visual cues. The results indicate that a comparable level of performance was achieved for each test case; however, an increase in pilot workload was noted when the TV system was used.

Dicarlo, D. J.↗

Flat H Redundant Frangible Joint Development

Orion and Commercial Crew Program (CCP) Partners have chosen to use frangible joints for certain separation events. The joints currently available are zero failure tolerant and will be used in mission safety applications. The goal is to further develop a NASA designed redundant frangible joint that will lower flight risk and increase reliability. FY16 testing revealed a successful design in subscale straight test specimens that gained efficiency and supports Orion load requirements. Approach / Innovation A design constraint is that the redundant joint must fit within the current Orion architecture, without the need for additional vehicle modification. This limitation required a design that changed the orientation of the expanding tube assemblies (XTAs), by rotating them 90deg from the standard joint configuration. The change is not trivial and affects the fracture mechanism and structural load paths. To address these changes, the design incorporates cantilevered arms on the break plate. The shock transmission and expansion of the XTA applies force to these arms and creates a prying motion to push the plate walls outward to the point of structural failure at the notched section. The 2014 test design revealed that parts could slip during functioning wasting valuable energy needed to separate the structure with only a single XTA functioning. Dual XTA functioning fully separated the assembly showing a discrepancy can be backed up with redundancy. Work on other fully redundant systems outside NASA is limited to a few patents that have not been subjected to functionality testing Design changes to prevent unwanted slippage (with ICA funding in 2015) showed success with a single XTA. The main goal for FY 2016 was to send the new Flat H RFJ to WSTF where single XTA test failures occurred back in 2014. The plan was to gain efficiency in this design by separating the Flat H RFJ with thicker ligaments with dimensions baselined in 2014. Other modifications included geometry changes to better disperse loads paths and to minimize air gaps. The design additionally added more structural strength to enhance the structural limits in static loads testing. The design also implemented a smoother load line through the assembly. Results / Knowledge Gained The new Flat H RFJ successfully fractured at WSTF with thicker ligaments and lower cord size. Where failure to separate occurred earlier, there is now excessive energy available for structural separation. The new challenge to provide some structural support to prevent secondary fracturing of the break plate remains to be completed. This future work is being funded by the JSC Engineering Directorate in 2017 to elevate the TRL on curved Flat H RFJs that configure with the Orion Service Panel Separation. Additional funding from JSC Engineering will provide new design testing to avoid secondary fracturing.

Brown, Chris↗

Recent test results on lithium BCX cells

Texts included: short circuit analysis, voltage reversal, high temperature exposure, parallel loading sharing, capacity tests, shock and vibration tests, and assembly tests. Both the AA and D cell configurations were tested. Certification of the cells is discussed and applications are highlighted.

Bragg, B. J.↗

Simulated Lunar Testing of Metabolic Heat Regenerated Temperature Swing Adsorption Technology

Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is being developed for thermal and carbon dioxide (CO2) control for a Portable Life Support System (PLSS), as well as water recycling. An Engineering Development Unit (EDU) of the MTSA subassembly was designed and assembled for optimized Martian operations, but also meets system requirements for lunar operations. For lunar operations the MTSA sorption cycle is driven via a vacuum swing between suit ventilation loop pressure and lunar vacuum. The focus of this effort is operations and testing in a simulated lunar environment. This environment was simulated in Paragon s EHF vacuum chamber. The objective of this testing was to evaluate the full cycle performance of the MTSA Subassembly EDU, and to assess CO2 loading and pressure drop of the wash coated aluminum reticulated foam sorbent bed. The lunar testing proved out the feasibility of pure vacuum swing operation, making MTSA a technology that can be tested and used on the Moon prior to going to Mars. Testing demonstrated better than expected CO2 loading on the sorbent and nearly replicates the equilibrium data from the sorbent manufacturer. This had not been achieved in any of the previous sorbent loading tests performed by Paragon. Subsequently, the increased performance of the sorbent bed design indicates future designs will require less mass and volume than the current EDU rendering MTSA as very competitive for Martian PLSS applications.

Padilla, Sebastian A.↗

Fatigue crack growth under variable amplitude loading

Fatigue crack growth tests were conducted on an Fe 510 E C-Mn steel and a submerged arc welded joint from the same material under constant, variable, and random loading amplitudes. Paris-Erdogan's crack growth rate law was tested for the evaluation of m and C using the stress intensity factor K, the J-integral, the effective stress intensity factor K(sub eff), and the root mean square stress intensity factor K(sub rms) fracture mechanics concepts. The effect of retardation and residual stresses resulting from welding was also considered. It was found that all concepts gave good life predictions in all cases.

Sidawi, Jihad A.↗