Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ion source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Using Forward-Reversal Integration to Optimize EIC's e-ring Dynamic Aperture

The forward-reversal integration has been proved efficient in optimizing the dynamic aperture for light source rings, which usually have a multi-fold periodical lattice structure. This method has been integrated into the ELEGANT code since the version 2019.4. In this technote, this approach has been used to optimize the dynamic aperture of a collider ring, i.e., the future electron ion collider’s (EIC) e-ring.

43 PARTICLE ACCELERATORS↗

Double-power-law Feature of Energetic Particles Accelerated at Coronal Shocks

Recent observations have shown that in many large solar energetic particle (SEP) events the event-integrated differential spectra resemble double power laws. We perform numerical modeling of particle acceleration at coronal shocks propagating through a streamer-like magnetic field by solving the Parker transport equation, including protons and heavier ions. We find that for all ion species the energy spectra integrated over the simulation domain can be described by a double power law, and the break energy depends on the ion charge-to-mass ratio as E B ~ (Q/A) α , with α varying from 0.16 to 1.2 by considering different turbulence spectral indices. We suggest that the double-power-law distribution may emerge as a result of the superposition of energetic particles from different source regions where the acceleration rates differ significantly due to particle diffusion. The diffusion and mixing of energetic particles could also provide an explanation for the increase of Fe/O at high energies as observed in some SEP events. Although further mixing processes may occur, our simulations indicate that either a power-law break or rollover can occur near the Sun and predict that the spectral forms vary significantly along the shock front, which may be examined by upcoming near-Sun SEP measurements from the Parker Solar Probe and Solar Orbiter.

79 ASTRONOMY AND ASTROPHYSICS↗

Functionalized Magnetic Nanoparticles for Technetium Sequestration from Groundwater

Technetium 99 (Tc) is among the most common environmental contaminants at DOE sites and one of the most common risk drivers in low- and high-level waste disposal sites. The majority of Tc is generated from anthropogenic sources, such as nuclear power plants, global weapons, nuclear storage facilities and medical applications. Through these sources, Tc contamination has been unintentionally introduced in to the environment. The most common chemical form of Tc is Tc(VII)O{sub 4}{sup -}. Due to its high solubility and mobility, Tc can enter the food chain and cause adverse health effects to humans. Currently, ion exchange resins and reduction processes are the most common approaches for Tc immobilization. Although these techniques have shown to be effective, they also possess major drawbacks, such as high cost, low adsorption capacity, and complex creation and maintenance. Therefore, development of more efficient and simple technologies for the remediation of Tc-contaminated systems are needed. Functionalized magnetic nanoparticles have been used to remove organic and inorganic contaminants from water resources. These nanoparticles have attracted extensive attention as an adsorbent material due to their large surface area, high efficiency, low-cost, easy functionalization and separation with a magnet. This study seek to develop functionalized magnetic iron oxide nanoparticles for the efficient removal of Tc and other heavy metal contaminants from water resources under ambient conditions. Objectives: Synthesize magnetic iron oxide nanoparticles and functionalize their surface with Cetyltrimethylammonium Bromide (CTAB) and tetraethyl-orthosilicate (TEOS). Characterize the synthesized nanoparticles using scanning electron microscopy (SEM) coupled with energy dispersive X-ray spectroscopy (EDS), Dynamic Light Scattering (DLS) and Zeta PALS. Perform adsorption studies to evaluate their adsorption behavior and capacity for (a) Technetium using Rhenium (ReO{sub 4}{sup -}) as a surrogate and (b) heavy metals, e.g. Cu{sup 2+}. Conclusions: Magnetic iron oxide nanoparticles were successfully functionalized with CTAB and TEOS. The functionalization of the iron oxide nanoparticles affects their surface charge and their hydrodynamic diameter. The addition of CTAB or TEOS decreased the hydrodynamic diameter of the nanoparticles due to repulsive and steric forces. The SEM micrographs show spherical nanoparticles of different sizes. The EDX analysis shows the presence of iron and oxygen from the iron oxide crystalline structure, and the different constituents of the CTAB and TEOS molecules. Proof-of-concept shows the successful adsorption of rhenium (ReO{sub 4}{sup -}) and copper Cu{sup 2+}) onto CTAB-Fe{sub 2}O{sub 3} and TEOS-Fe{sub 2}O{sub 3} respectively.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Molten Salt Assisted Low-Temperature Electro-Catalytic Graphitization of Coal Chars

A great effort has been centered around developing clean energy technologies (energy storage devices) to curtail burning fossil fuels' deleterious environmental effects. Rechargeable batteries [lithium-ion batteries (LIBs)] are among the most invested and investigated storage devices showing potential to transform fossil fuel-powered mobility to next-generation safe electromobility. However, LIBs powered electric vehicles (EV) are expensive due to the high-cost graphite anode associated with LIBs. Herein, the synthesis of low-cost, highly crystalline nano-graphite with a tunable microstructural architecture has been demonstrated via molten salt assisted low-temperature electro-catalytic graphitization of coal chars, traditionally non-graphitizable carbon. Thus, graphite derived from coal chars exhibited nanoflake architecture and delivered high reversible capacity, stable long cycle life, and excellent electrochemical performance under fast charging/discharging conditions (5C, ~12 min charge/discharge time). This finding paves the way to manufacture cost-effective high-energy-density batteries using as-synthesized graphite from readily available coal sources that could propel the EVs to the next level.

25 ENERGY STORAGE↗

Degradation Mechanism Due to Water Ingress Effect on the Top Contact of Cu(In,Ga)Se2 Solar Cells

The impact of moisture ingress on the surface of copper indium gallium diselenide (CIGS) solar cells was studied. While industry-scale modules are encapsulated in specialized polymers and glass, over time, the glass can break and the encapsulant can degrade. During such conditions, water can potentially degrade the interior layers and decrease performance. The first layer the water will come in contact with is the transparent conductive oxide (TCO) layer. To simulate the impact of this moisture ingress, complete devices were immersed in deionized water. To identify the potential sources of degradation, a common window layer for CIGS devices—a bilayer of intrinsic zinc oxide (i-ZnO) and conductive indium tin oxide (ITO)—was deposited. The thin films were then analyzed both pre and post water soaking. To determine the extent of ingress, dynamic secondary ion mass spectroscopy (SIMS) was performed on completed devices to analyze impurity diffusion (predominantly sodium and potassium) in the devices. The results were compared to device measurements, and indicated a degradation of device efficiency (mostly fill factor, contrary to previous studies), potentially due to a modification of the alkali profile.

14 SOLAR ENERGY↗

Atmospheric-pressure ionization and fragmentation of molecules for structural elucidation

A solution-cathode glow discharge mass spectrometry (SCGD-MS) apparatus comprises a SCGD source and a mass spectrometer. The SCGD source may comprise conductive rods, a power source, and a capillary. A method for ionizing an analyte comprises flowing an electrically conductive liquid onto a conductive rod, applying an electric potential to a second conductive rod such that a plasma discharge forms between the first conductive rod and the electrically conductive liquid to produce ions, and separating the ions in a mass spectrometer. The analyte may be a polypeptide that may be contacted with trypsin. The analyte may be a solid, liquid, gas, chemical complex, or ion in solution. The method may comprise sequencing the polypeptide.

Shelley, Jacob T.↗

Capacity and Coulombic Efficiency Measurements Underestimate the Rate of SEI Growth in Silicon Anodes

Capacity measurements and related quantities are the first layer of information acquired during testing of Li-ion cells. It is generally considered that elevated values of coulombic efficiency and capacity retention are absolute indicators of the existence of a stable solid electrolyte interphase (SEI). Here, we challenge this notion by analyzing how the effect of side reactions on cell capacity depends on the choice of electrodes. More specifically, we demonstrate that the extent of measurable capacity fade due to SEI growth is modulated by the shape of the voltage profile of the cathode and anode at the end of charge and discharge half-cycles. This shape-dependency creates a mismatch between SEI growth and cell capacity loss, which is relatively small for graphite anodes but sizable for silicon-containing electrodes. We illustrate this point by showing that, at the same coulombic efficiency and capacity retention, cells containing silicon-based materials could actually exhibit rates of SEI growth that are as much as ≥ 40% higher than graphite cells. The main implication of this behavior is that, for certain systems, capacity measurements may be an unreliable source of information about the extent of reactions at the SEI, allowing other consequences of these side reactions (such as electrolyte depletion) to proceed unchecked while the cell appears to be stable.

25 ENERGY STORAGE↗

On Alfvénic turbulence of solar wind streams observed by Solar Orbiter during March 2022 perihelion and their source regions

It has been recently accepted that the standard classification of the solar wind solely according to flow speed is outdated, and particular interest has been devoted to the study of the origin and evolution of so-called Alfvénic slow solar wind streams and to what extent such streams resemble or differ from fast wind. In March 2022, Solar Orbiter completed its first nominal phase perihelion passage. During this interval, it observed several Alfvénic streams, allowing for characterization of fluctuations in three slow wind intervals (AS1-AS3) and comparison with a fast wind stream (F) at almost the same heliocentric distance. This work makes use of Solar Orbiter plasma parameters from the Solar Wind Analyzer (SWA) and magnetic field measurements from the magnetometer (MAG). The magnetic connectivity to the solar sources of selected solar wind intervals was reconstructed using a ballistic extrapolation based on measured solar wind speed down to the (spherical) source surface at 2.5 R s below which a potential field extrapolation was used to map back to the Sun. The source regions were identified using SDO/AIA observations. A spectral analysis of in situ measured magnetic field and velocity fluctuations was performed to characterize correlations, Alfvénicity, normalized cross-helicity, and residual energy in the frequency domain as well as intermittency of the fluctuations and spectral energy transfer rate estimated via mixed third-order moments. A machine learning technique was used to separate proton core, proton beam, and alpha particles and to study v − b correlations for the different ion populations in order to evaluate the role played by each population in determining the Alfvénic content of solar wind fluctuations. The comparison between fast wind and Alfvénic slow wind intervals highlights the differences between the two solar wind regimes: The fast wind is characterized by larger amplitude fluctuations, and magnetic and velocity fluctuations are closer to equipartition of energy. In fact the Alfvénic slow wind streams appear to be on a spectrum of wind types, with AS1, originating from open field lines neighboring active regions and displaying similarities with the fast wind in terms of fluctuation amplitude and turbulence characteristics, but not with respect to the alpha particles and proton beams. The other two slow streams differed both in their sources as well as plasma characteristics, with AS2 coming from the expansion of a narrow coronal hole corridor and AS3 from a region straddling a pseudostreamer. The latter displayed the coldest and highest density but the slowest stream with the smallest fluctuation amplitude and greatest magnetic energy excess. It also showed the largest scatter in proton beam speeds and the greatest difference in speed between proton beam and alpha particles. This study shows how the old fast–slow solar wind dichotomy, already called into question by the observations of slower Alfvénic solar wind streams, should further be refined, as the Alfvénic slow wind, originating in different solar wind regions, show significant differences in density, temperature, and proton and alpha-particle properties in the inner heliosphere. The observations presented here provide the starting point for a better understanding of the origin and evolution of different solar wind streams as well as the evolving turbulence contained within.

magnetohydrodynamics (MHD)↗

Computational tools and algorithms for ion mobility spectrometry-mass spectrometry

Ion mobility spectrometry-mass spectrometry (IMS-MS or IM-MS) is a powerful analytical technique that combines the gas-phase separation capabilities of IM with the identification and quantification capabilities of MS. IM-MS can differentiate molecules with indistinguishable masses but different structures (e.g., isomers, isobars, molecular classes, and contaminant ions). The importance of this analytical technique is reflected by a staged increase in the number of applications for molecular characterization across a variety of fields, from different MS-based omics (proteomics, metabolomics, lipidomics, etc.) to the structural characterization of glycans, organic matter, proteins, and macromolecular complexes. With the increasing application of IM-MS there is a pressing need for effective and accessible computational tools. This article presents an overview of the most recent free and open-source software tools specifically tailored for the analysis and interpretation of data derived from IM-MS instrumentation. This review enumerates these tools and outlines their main algorithmic approaches, while highlighting representative applications across different fields. Finally, a discussion of current limitations and expectable improvements is presented.

59 BASIC BIOLOGICAL SCIENCES↗

Advanced focusing system for secondary electrons in a bunch shape monitor

Non-destructive measurements of longitudinal beam profile in non-relativistic hadron accelerators are usually performed with Bunch Shape Monitors that utilize secondary electron emission to reproduce the shape of a primary ion beam. The existing devices, however, have poor electron collection efficiency from the wire and are limited to one dimensional measurements of the phase coordinate. Here, we present the development of a bunch shape monitor with improved performance for proton beams to be used in the Spallation Neutron Source accelerator. This improvement was achieved by adding focusing optics between the wire and the entrance slit, which will also allow measurements over a much higher dynamic range. Here we present the design, simulation and experimental test results of the developed new electron beam guidance system for the existing SNS bunch shape monitor that allowed significant improvement in the collection efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of tantalum deposition and growth on TiB2 and ZrB2 from PISCES-RF deuterium and helium plasma exposures

Deuterium and helium plasma exposures on bulk TiB2 and ZrB2 samples were performed using the PISCES-RF linear plasma device. 40 and 90 eV deuterium ion plasma exposures were performed at 240 and 800 °C sample temperatures, and 80 eV helium ion plasma exposures were performed at 800 °C sample temperatures. Following plasma exposures, it was discovered that two plasma conditions (90 eV deuterium and 80 eV helium at 800 °C) resulted in thick (>200 nm) tantalum-rich (>10 at%) surface features on the targets, presumably from tantalum sourced from a tantalum adapter mask or cap used as part of the target holder. This work aims to characterize these tantalum-rich features and examine the mechanisms of impurity deposition.Plasma-induced surface morphology of the tantalum-rich surface layers depends on plasma properties and target temperature and chemistry. Greater titanium sputtering compared to zirconium resulted in more distinct surface features in the TiB2 samples compared to the ZrB2 samples via increased, prompt deposition onto tantalum surface impurities. There is still uncertainty as to why thick tantalum deposition only occurred under some plasma exposure conditions but not others; it is likely due to tantalum sputtering by a combination of boron molecules from the targets and carbon-impurities in the tantalum mask or targets. Impurity driven surface features are a well-documented phenomena in samples exposed to plasma from linear plasma device facilities—this work confirms the occurrence of this and emphasizes the need for chemistry characterization of isolated post-mortem surface features in plasma-exposed samples.

Nuckols, Lauren↗

Microsecond Molecular Dynamics Simulations of Proteins Using a Quasi-Equilibrium Solvation Shell Model

In this work, we describe the development and implementation of a quasi-equilibrium hydration shell model of biomolecular solvation with adaptive boundaries. Applying the model to microsecond-long molecular dynamics simulations of several protein systems of varying complexity, we find that the model simulation results are of comparable quality to those obtained from simulations of fully solvated systems, but at a reduced computational cost. We discuss the dominant sources of error in the model and outline directions for future improvements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Overview of the JET preparation for deuterium–tritium operation with the ITER like-wall

For the past several years, the JET scientific programme (Pamela et al 2007 Fusion Eng. Des. 82 590) has been engaged in a multi-campaign effort, including experiments in D, H and T, leading up to 2020 and the first experiments with 50%/50% D–T mixtures since 1997 and the first ever D–T plasmas with the ITER mix of plasma-facing component materials. For this purpose, a concerted physics and technology programme was launched with a view to prepare the D–T campaign (DTE2). This paper addresses the key elements developed by the JET programme directly contributing to the D–T preparation. This intense preparation includes the review of the physics basis for the D–T operational scenarios, including the fusion power predictions through first principle and integrated modelling, and the impact of isotopes in the operation and physics of D–T plasmas (thermal and particle transport, high confinement mode (H-mode) access, Be and W erosion, fuel recovery, etc). This effort also requires improving several aspects of plasma operation for DTE2, such as real time control schemes, heat load control, disruption avoidance and a mitigation system (including the installation of a new shattered pellet injector), novel ion cyclotron resonance heating schemes (such as the three-ions scheme), new diagnostics (neutron camera and spectrometer, active Alfvèn eigenmode antennas, neutral gauges, radiation hard imaging systems...) and the calibration of the JET neutron diagnostics at 14 MeV for accurate fusion power measurement. The active preparation of JET for the 2020 D–T campaign provides an incomparable source of information and a basis for the future D–T operation of ITER, and it is also foreseen that a large number of key physics issues will be addressed in support of burning plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neural-Network-Enhanced COTSIM: Advancing Predictive Capabilities for Fast DIII-D Simulations

Sustaining fusion reactions in tokamaks requires heating plasma to thermonuclear temperatures while maintaining confinement and stability. Neutral beam injection (NBI) provides heating, current drive, torque, and fueling, while electron cyclotron (EC) waves are widely used for heating and current drive; together, these actuators shape the plasma current, temperature, and density profiles. The control-oriented tokamak simulator (COTSIM), a predictive, control-oriented code, has been enhanced with neural-network surrogates for transport and sources. Turbulent transport is predicted by MMMnet—a neural-network version of the updated multimode model (MMM 9.0.10)—with significantly reduced computation time relative to MMM; neoclassical transport follows the Chang–Hinton model. NUBEAMnet, a surrogate of the Monte Carlo NUBEAM module, predicts beam-driven heating, current, and torque. EC heating and current drive use a control-oriented, empirically scaled source model; plasma resistivity follows the Spitzer formulation; bootstrap current uses the Sauter model. Equilibrium is computed using both prescribed and fixed-boundary solvers (FBSs), and the pedestal structure is modeled with an empirical pedestal model. For a representative DIII-D discharge, COTSIM predicts electron and ion temperature and safety-factor profiles in close agreement with TRANSP predictive and interpretive simulations while extending predictions through the pedestal region to the plasma edge (versus 80% of the minor radius in TRANSP). Furthermore, the equivalent COTSIM simulation runs in under 3 min compared to about 2 h for TRANSP, enabling rapid scenario planning, optimization of tokamak operation, and between-pulse control design.

Control-oriented tokamak simulator (COTSIM)↗

Salts in Hot Water: Developing a Scientific Basis for Supercritical Desalination and Strategic Metal Recovery

Given the steady growth in world population and the ever-increasing fresh water demand, the only sustainable water supply option is desalination. Conceptually, desalination is very simple - just separate dissolved salts from water. While desalination research programs have existed since the 1960s and have resulted in a multitude of approaches, realizing affordable desalination has proven to be a challenge. Our goal is to meet this challenge using low cost heat sources to drive a liquid-discharge-free desalination process that can be co-mingled with the extraction of economically valuable co-products. High temperatures and pressures will be used to manipulate water’s properties, such as the dielectric constant, and hence its ability to solvate ions. Selective precipitation/recovery of valuable metal co-products creates new revenue streams (i.e., cost offsets). We will develop the scientific understanding necessary to control salt precipitation from supercritical seawater, inland brines, and water commonly co-produced with oil and gas. Atomistic simulations will be used to understand at a molecular level the changes in hydrogen bonding and ion solvation that occur as we increase the temperature and/or pressure and change the density and ion concentration. Our simulation results will also aid in the interpretation of experimental data and guide the development of applied thermodynamic models for engineering design calculations.

58 GEOSCIENCES↗

Plasma-Based Ambient Desorption/Ionization Mass Spectrometry for the Analysis of Liquid Crystals Employed in Display Devices

Liquid-crystal displays (LCDs) are the most frequently used display technology worldwide these days. Due to the rather complex manufacturing process and purity requirements for the chemicals used, quality control and display failure analysis are important analytical tasks. Currently, the state-of-the-art techniques (e.g., high-performance liquid chromatography (HPLC), gas chromatography (GC) coupled to mass spectrometry (MS), time-of-flight secondary ion mass spectrometry (TOF-SIMS), or high-resolution microscopy) are costly and time-consuming. Hence, a new pathway to precisely analyze liquid-crystalline materials and LCDs in their native state is reported. A new approach for direct analysis via plasma-based ambient desorption/ionization mass spectrometry (ADI-MS) offers an inexpensive and faster alternative. In this study, direct analysis in real time (DART), the low-temperature plasma (LTP) probe, and flowing atmospheric-pressure afterglow (FAPA) ADI sources coupled to high-resolution mass spectrometry (HR-MS) are compared based on their capabilities and performance for liquid-crystal analysis. These sources enable direct analyte desorption from a sample surface at ambient conditions and ionize the vaporized analyte molecules in a subsequent step. Primarily, the ionization capabilities of the three ADI sources are compared for individual liquid-crystal standards, mixtures of liquid crystals (LCs), and complex liquid crystal/additive mixtures applied in commercially available LCDs. Furthermore, direct surface analysis from a glass substrate is also performed with ADI-MS to compare their applicability to this type of sample matrix. .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of the materials analysis and particle probe for Proto-MPEX

The Prototype Material Plasma Exposure eXperiment (Proto-MPEX) is a linear plasma device being used in plasma source research and development (R&D) for the proposed MPEX. Once the R&D is completed, this device can also be used to perform plasma–material interaction studies. To perform these studies, a new materials analysis and particle probe (MAPP) has been constructed. The MAPP’s components are a sample holder and manipulator and a custom vacuum chamber with ports to facilitate surface chemistry diagnostics. The MAPP’s overall design enables rapid sample turnaround and in vacuo surface characterization. The surface analysis vacuum chamber has ports for x-ray photoelectron spectroscopy, thermal desorption spectroscopy, back-scatter ion scattering spectroscopy, forward-scatter ion scattering spectroscopy, and direct recoil spectroscopy. The sample manipulator and holder is a Lesker/UHV Multi-Centre Analytical Stage, which is used to place the samples in the exposure region of the Proto-MPEX or the analysis position in the MAPP vacuum chamber. The sample holder has a heating capability of up to 1200 °C for heated exposure and for desorption studies. In this work, we present the MAPP’s design and the first tungsten sample exposure with ex situ analysis that shows a surface deposition layer on the exposed target, highlighting the need for additional in situ measurements on the Proto-MPEX.

Beers, C. J. (ORCID:0000000150985459)↗