Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “interference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Examining the Performance of Walsh-DSSS Against FBMC-SS in HF Channels

Abstract—Filter bank multicarrier spread spectrum (FBMCSS) has proven to be a robust and reliable waveform choice for communication over high frequency (HF) skywave links. However, the performance of this waveform has yet to be contextualized against typical robust HF waveforms, such as the Walsh-encoded waveform detailed in the MIL-STD-188-110D, Appendix D document. In this paper, we first outline the advantages of both the Walsh and FBMC-SS waveforms as well as present their developments. Simulation results are then presented for ideal, simulated HF, and HF with interference channel conditions. Lastly, skywave-HF results are presented for these two waveforms both with and without interference.

99 GENERAL AND MISCELLANEOUS↗

Temperature-Dependent Light-Stabilized States in Thin-Film PV Modules: Preprint

Thin-film photovoltaic modules are known to exhibit light-induced transient behavior which interferes with accurate and repeatable measurements of power. Typically power measurements are made after a light exposure in order to target a 'light state' of the module that is representative of outdoor performance. Here we show that the concept of a unique light state is poorly defined for both CIGS and CdTe modules. Instead we find that their metastable state after a light exposure can depend on the temperature of the module during the exposure. We observe changes in power as large as 5.8% for a 20 degrees C difference in light exposure temperature. These results lead us to conclude that for applications in which reproducibility and repeatability are critical, module temperature should be tightly controlled during light exposure.

14 SOLAR ENERGY↗

Analyzing Single Giant Unilamellar Vesicles With a Slotline-Based RF Nanometer Sensor

Novel techniques that enable reagent free detection and analysis of single cells are of great interest for the development of biological and medical sciences as well as point-of-care health service technologies. Highly sensitive and broadband radio-frequency (RF) sensors are promising candidates for such a technique. In this work, we present a highly sensitive and tunable RF sensor, which is based on interference processes and built with a 100 nm slotline structure. The highly concentrated RF fields, up to ~1.76×107 V/m, enable strong interactions between Giant unilamellar vesicles (GUVs) and fields for high sensitivity operations. We also provide two modeling approaches to extract cell dielectric properties from measured scattering parameters. GUVs of different molecular compositions are synthesized and analyzed with the RF sensor at ~2 GHz, ~2.5 GHz, and ~2.8 GHz with an initial |S21|min of ~-100 dB. Corresponding GUV dielectric properties are obtained. A one-dimensional scanning of single GUV is also demonstrated.

Cui, Yan↗

Data-Driven Robust M-LS-SVR-Based NARX Modeling for Estimation and Control of Molten Iron Quality Indices in Blast Furnace Ironmaking

Optimal operation of an industrial blast furnace (BF) ironmaking process largely depends on a reliable measurement of molten iron quality (MIQ), which is not feasible using the conventional sensors. This paper proposes a novel data-driven robust modeling method for online estimation and control of MIQ indices. First, to completely capture the nonlinear dynamics of the BF process, the nonlinear autoregressive exogenous (NARX) model is constructed for the MIQ indices. Then, considering that the standard least-squares support vector regression (LS-SVR) cannot directly cope with the multi-output problem, the multi- task transfer learning is proposed to design a novel multi-output LS-SVR (M-LS-SVR) for learning of the NARX model. Furthermore, a novel M-estimator is proposed to reduce the interference of outliers and improve the robustness of the M-LS- SVR model. Since the weights of different outlier data are properly given by the weight function, their corresponding contributions on modeling can be properly distinguished, thus a robust modeling result can be achieved. Finally, a novel multi- objective evaluation index on modeling performance is developed by comprehensively considering the root mean square error of modeling and the correlation coefficient on trend fitting, based on which the NSGA-II algorithm is used to globally optimize the model parameters. Both experiments using industrial data and industrial applications illustrate that the proposed method can eliminate the adverse effect caused by the fluctuation of data in BF process efficiently, which indicates its stronger robustness and higher accuracy. Moreover, control testing shows that the developed model can be well applied to realize data-driven control of the BF process.

blast cavities, Control↗

Argobots: A Lightweight Low-Level Threading and Tasking Framework

In the past few decades, a number of user-level threading and tasking models have been proposed in the literature to address the shortcomings of OS-level threads, primarily with respect to cost and flexibility. Current state-of-the-art user-level threading and tasking models, however, are either too specific to applications or architectures or are not as powerful or flexible. In this paper, we present Argobots, a lightweight, low-level threading and tasking framework that is designed as a portable and performant substrate for high-level programming models or runtime systems. Argobots offers a carefully designed execution model that balances generality of functionality with providing a rich set of controls to allow specialization by the user or high-level programming model. We describe the design, implementation, and optimization of Argobots and present integrations with three example high-level models: OpenMP, MPI, and co-located I/O service. Evaluations show that (1) Argobots outperforms existing generic threading runtimes; (2) our OpenMP runtime offers more efficient interoperability capabilities than production OpenMP runtimes do; (3) when MPI interoperates with Argobots instead of Pthreads, it enjoys reduced synchronization costs and better latency hiding capabilities; and (4) I/O service with Argobots reduces interference with co-located applications, achieving performance competitive with that of the Pthreads version.

Seo, Sangmin (ORCID:0000000295159836)↗

Frequency Domain Detection and Precoding for Massive MIMO With Single Carrier Modulation

Single carrier modulation (SCM) schemes are attractive for uplink (UL) transmissions due to improved power efficiency at the user equipment (UE) transmitter compared with multi-carrier modulation schemes. In a massive MIMO scenario with SCM, the UL detection must mitigate the effects of inter-symbol interference and multiuser interference. This processing is effectively performed in the frequency domain (FD) using a minimum mean squared error (MMSE) detector when the transmission is framed with a cyclic prefix. This paper presents a MMSEbased detector that is compatible with distributed processing in a time-division duplex (TDD) system. The matrix inverses computed for the UL detection are then reused to perform multi-user precoding for the downlink (DL). We find that this scheme yields a tremendous savings in computational complexity compared to commonly used zero-forcing (ZF) precoding without sacrificing any performance. Since MMSE processing introduces a bias to the estimates, we then derive the scalar coefficients necessary to cancel the MMSE bias. The impact of channel estimation errors are analyzed for both the UL and DL cases in conjunction with a power-efficient approach to SCM channel estimation. Moreover, extensive simulations are performed to confirm our theoretical findings.

42 ENGINEERING↗

Uncoordinated Spectrum Sharing in Millimeter Wave Networks Using Carrier Sensing

Here, we propose using Carrier Sensing (CS) for distributed interference management in millimeter-wave (mmWave) cellular networks where spectrum is shared by multiple operators that do not coordinate among themselves. In addition, even the base station sites can be shared by the operators. We describe important challenges in using traditional CS in this setting and propose enhanced CS protocols to address these challenges. Using stochastic geometry, we develop a general framework for downlink coverage probability analysis of our shared mmWave network in the presence of CS and derive the downlink coverage probability expressions for several CS protocols. Our work is the first to investigate and analyze (using stochastic geometry) CS for mmWave networks with spectrum and BS sites shared among non-coordinating operators. We evaluate the downlink coverage probability of our shared mmWave network using simulations as well as numerical examples based on our analysis. Our evaluations show that our proposed approach leads to an improvement in coverage probability, compared to the coverage probability with no CS, for higher values of signal-to-interference and noise ratio (SINR). Interestingly, our evaluations also reveal that for lower values of SINR, not using any CS is the best strategy in terms of the downlink coverage probability.

42 ENGINEERING↗

Practical benzylation of N,N -substituted ethanolamines related to chemical warfare agents for analysis and detection by Electron Ionization Gas Chromatography-Mass Spectrometry

The benzylation of three, low-molecular weight N,N-disubstituted ethanolamines related to chemical warfare agents (CWAs) to furnish derivatives with improved Gas Chromatography-Mass Spectrometry (GC-MS) profiles is described. Due to their low molecular weight and polar nature, N,N-disubstituted ethanolamines are notoriously difficult to detect by routine GC-MS analyses during Organisation for the Prohibition of Chemical Weapons (OPCW) proficiency tests (PTs), particularly in scenarios when they are present at low levels (~1-10 ppm) amidst more abundant interferences. Our studies revealed that the optimal derivatization conditions involved the treatment of the ethanolamine with benzyl bromide in the presence of an inorganic base (e.g., Na 2 CO 3 ) in dichloromethane at 55 °C for 2 hours. This optimized set of conditions were then successfully applied to the derivatization of N,N-dimethylethanolamine, N,N-diethylethanolamine and N,N-diisopropylethanolamine present separately at 1 and 10 μg/mL concentrations in a glycerol-rich matrix sample featured in the 48 th OPCW PT. The benzylated derivatives of the three ethanolamines possessed retention times long enough to clear the massive glycerol-containing matrix interferences. In conclusion, the protocol herein is introduced as an alternative method for derivatization of these CWA and pharmaceutically important species and should find broad applicability in laboratories where their routine forensic analysis is carried out.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Asymmetrical subcortical plasticity entails cognitive progression in older individuals

Abstract Structural brain asymmetries have been associated with cognition. However, it is not known to what extent neuropsychological parameters and structural laterality covary with aging. Seventy‐five subjects drawn from a larger normal aging cohort were evaluated in terms of MRI and neuropsychological parameters at two moments (M1 and M2), 18 months apart. In this time frame, asymmetry as measured by structural laterality index (ΔLI) was stable regarding both direction and magnitude in all areas. However, a significantly higher dispersion for this variation was observed in subcortical over cortical areas. Subjects with extreme increase in rightward lateralization of the caudate revealed increased M1 to M2 Stroop interference scores, but also a worsening of general cognition (MMSE). In contrast, subjects showing extreme increase in leftward lateralization of the thalamus presented higher increase in Stroop interference scores. In conclusion, while a decline in cognitive function was observed in the entire sample, regional brain asymmetries were relatively stable. Neuropsychological trajectories were associated with laterality changes in subcortical regions.

Esteves, Madalena↗

Pilot-scale electron cyclotron resonance-metal organic chemical vapor deposition system for the preparation of large-area fluorine-doped SnO{sub 2} thin films

The authors report the surface morphology, optical, electrical, thermal and humidity impacts, and electromagnetic interference properties of fluorine-doped tin oxide (SnO{sub 2}:F or “FTO”) thin films on a flexible polyethylene terephthalate (PET) substrate fabricated by a pilot-scale electron cyclotron resonance–metal organic chemical vapor deposition (PS ECR-MOCVD). The characteristics of large area FTO thin films were compared with a commercially available transparent conductive electrode made of tin-doped indium oxide (ITO), prepared with an identical film and PET thickness of 125 nm and 188 μm, respectively. The results revealed that the as-prepared FTO thin films exhibited comparable performances with the incumbent ITO films, including a high optical transmittance of 97% (substrate-subtracted), low electrical resistivity of about 5 × 10{sup −3} Ω cm, improved electrical and optical performances due to the external thermal and humidity impact, and an excellent shielding effectiveness of electromagnetic interference of nearly 2.3 dB. These excellent performances of the FTO thin films were strongly attributed to the design of the PS ECR-MOCVD, which enabled a uniform plasma environment resulting from a proper mixture of electromagnetic profiles and microwave power.

36 MATERIALS SCIENCE↗

Peak selection matters in Principal Component Analysis: A case study of syntrophic microbes

In situ liquid time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a powerful technique to address surface characterization of living biofilms in hydrated conditions. Principal component analysis (PCA) is an important tool to process a large amount of data and interpret the information from ToF-SIMS spectra. However, ToF-SIMS data analysis is still a great challenge in complicated bacterial biofilms, because many interference peaks from the medium may result in inaccurate interpretation of ToF-SIMS spectral analysis. In this study, two syntrophic Geobacter populations were investigated using in situ liquid ToF-SIMS to reveal the biofilm surface changes between them as due to direct interspecies electron transfer (DIET). Peak overlay is an effective strategy to eliminate the matrix effects in handling complex ToF-SIMS data and was used to accomplish peak selection in this work. Both all peak and selected peak spectral PCA showed a distinctive separation among different samples. However, medium samples occupied high scores values in all peak PCA compared with the selected peak PCA, suggesting a strong interference from the medium as the matrix effect. Amino acids and lipids contributed significantly in separating all samples in selected peak PCA, which indicated that surface membrane components such as pili and proteins are important in the co-cultured Geobacter community compared to controls such as the single population planktonic cells and biofilms, respectively. Additionally, the spectral PCA results of high intensity and high resolution data obtained from liquid ToF-SIMS were compared. Selected peak PCA obtained nice separation among samples in both data sets; however, the high resolution data showed better separation between co-culture planktonics and co-culture aggregates, confirming that the higher mass accuracy is useful in analysis of microbial samples. Furthermore, amino acid and water cluster as an important media for microbial metabolite were selected for a more focused selected peak PCA comparison. Consistent scores and loadings plots were achieved. In conclusion, we show that peak selection is critical for acquiring effective microbial information and interpretation of syntrophic Geobacter using spectral data from in situ liquid ToF-SIMS.

spectral overlay, peak selection, matrix effect, P↗

In-flight performance of the XRISM/Resolve detector system

The Resolve instrument was launched on board the XRISM observatory in early September 2023. The Resolve spectrometer is based on a high-sensitivity X-ray calorimeter detector system (DS) that has been successfully deployed in many ground and sub-orbital spectrometers. However, the Resolve instrument is the first long-term implementation in space. The instrument will provide essential diagnostics for nearly every class of X-ray emitting objects, from galactic supernova remnants to the outskirts of galaxy clusters, without degradation for spatially extended objects. The Resolve DS consists of a 36-pixel microcalorimeter array operated at a heat sink temperature of 50 mK. In pre-flight testing, the DS demonstrated a resolving power of better than 1300 at 6 keV with a simultaneous bandpass from below 0.3 keV to above 12 keV and a timing precision better than 100μs. An anti-coincidence detector placed directly behind the microcalorimeter array effectively suppresses background. The detector energy-resolution budget included terms for interference from the Resolve cooling system and the spacecraft. Additional terms for energy-scale stability, on-orbit effects, and use of mid-grade events were also included, predicting an end-of-life, on-orbit performance for high- and mid-resolution grade events that meet the requirement of 7 eV FWHM at 6 keV. Here, we discuss the actual on-orbit performance of the Resolve DS and compare this with the performance in pre-flight testing, on-orbit predictions, and the almost identical Hitomi/SXS instrument. We will also discuss the on-orbit gain stability, an assessment of on-orbit interference, and measurements of the on-orbit background.

Astronomy and AstroPhysics↗

Conceptual design of the modular detector and readout system for the CMB-S4 survey experiment

We present the conceptual design of the modular detector and readout system for the Cosmic Microwave Background – Stage four (CMB-S4) ground-based survey experiment. CMB-S4 will map the cosmic microwave background (CMB) and the millimeter-wave sky to unprecedented sensitivity, using 500,000 superconducting detectors observing from Chile and Antarctica to map over 60% of the sky. The fundamental building block of the detector and readout system is a detector module package operated at 100 mK, which is connected to a readout and amplification chain that carries signals out to room temperature. It uses arrays of feedhorn-coupled orthomode transducers (OMT) that collect optical power from the sky onto dc-voltage-biased transition-edge sensor (TES) bolometers. The resulting current signal in the TESs is then amplified by a two-stage cryogenic Superconducting Quantum Interference Device (SQUID) system with a time-division multiplexer to reduce wire count, and matching room-temperature electronics to condition and transmit signals to the data acquisition system. Sensitivity and systematics requirements are being developed for the detector and readout system over wide range of observing bands (20 to 300 GHz) and optical powers to accomplish CMB-S4’s science goals. While the design incorporates the successes of previous generations of CMB instruments, CMB-S4 requires an order of magnitude more detectors than any prior experiment. This requires fabrication of complex superconducting circuits on over 10 m2 of silicon, as well as significant amounts of precision wiring, assembly and cryogenic testing

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical constants measurements of liquids for modeling aerosolized threats

Spectroscopic identification of aerosolized chemical threats is challenging due to the complex nature of the photon/particle interaction, as well as the diversity of possible particle sizes, morphologies, and compositions. Constructing a database of laboratory - measured transmittance spectra that covers each permutation is not practical. However, calculation of the spectra using the measured optical constants as a function of wavenumber, n(?) and k(?), for each of the liquids and/or solids composing the aerosol particles provides a viable alternative. These synthetic spectra (vis-à-vis laboratory-measured spectra) can be used to identify chemicals of interest and subtract out background interferents in field measurements. Using a well-established multiple pathlength approach, we measure the optical constants n/k for liquids that may be found as chemical species of interest or common background interferents aerosolized in plumes. These measurements are also used to generate several test case aerosol synthetic spectra.

Lockwood, Schuyler↗

An RF dosimeter for independent SAR measurement in MRI scanners

Purpose: The monitoring and management of radio frequency (RF) exposure is critical for ensuring magnetic resonance imaging (MRI) safety. Commercial MRI scanners can overestimate specific absorption rates (SAR) and improperly restrict clinical MRI scans or the application of new MRI sequences, while underestimation of SAR can lead to tissue heating and thermal injury. Accurate scanner-independent RF dosimetry is essential for measuring actual exposure when SAR is critical for ensuring regulatory compliance and MRI safety, for establishing RF exposure while evaluating interventional leads and devices, and for routine MRI quality assessment by medical physicists. However, at present there are no scanner-independent SAR dosimeters. Methods: An SAR dosimeter with an RF transducer comprises two orthogonal, rectangular copper loops and a spherical MRI phantom. The transducer is placed in the magnet bore and calibrated to approximate the resistive loading of the scanner's whole-body birdcage RF coil for human subjects in Philips, GE and Siemens 3 tesla (3T) MRI scanners. The transducer loop reactances are adjusted to minimize interference with the transmit RF field (B{sub 1}) at the MRI frequency. Power from the RF transducer is sampled with a high dynamic range power monitor and recorded on a computer. The deposited power is calibrated and tested on eight different MRI scanners. Whole-body absorbed power vs weight and body mass index (BMI) is measured directly on 26 subjects. Results: A single linear calibration curve sufficed for RF dosimetry at 127.8 MHz on three different Philips and three GE 3T MRI scanners. An RF dosimeter operating at 123.2 MHz on two Siemens 3T scanners required a separate transducer and a slightly different calibration curve. Measurement accuracy was ∼3%. With the torso landmarked at the xiphoid, human adult whole‑body absorbed power varied approximately linearly with patient weight and BMI. This indicates that whole-body torso SAR is on average independent of the imaging subject, albeit with fluctuations. Conclusions: Our 3T RF dosimeter and transducers accurately measure RF exposure in body-equivalent loads and provide scanner-independent assessments of whole-body RF power deposition for establishing safety compliance useful for MRI sequence and device testing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Seeing the invisible: Direct visualization of therapeutic radiation beams using air scintillation

Purpose: To assess whether air scintillation produced during standard radiation treatments can be visualized and used to monitor a beam in a nonperturbing manner. Methods: Air scintillation is caused by the excitation of nitrogen gas by ionizing radiation. This weak emission occurs predominantly in the 300–430 nm range. An electron-multiplication charge-coupled device camera, outfitted with an f/0.95 lens, was used to capture air scintillation produced by kilovoltage photon beams and megavoltage electron beams used in radiation therapy. The treatment rooms were prepared to block background light and a short-pass filter was utilized to block light above 440 nm. Results: Air scintillation from an orthovoltage unit (50 kVp, 30 mA) was visualized with a relatively short exposure time (10 s) and showed an inverse falloff (r{sup 2} = 0.89). Electron beams were also imaged. For a fixed exposure time (100 s), air scintillation was proportional to dose rate (r{sup 2} = 0.9998). As energy increased, the divergence of the electron beam decreased and the penumbra improved. By irradiating a transparent phantom, the authors also showed that Cherenkov luminescence did not interfere with the detection of air scintillation. In a final illustration of the capabilities of this new technique, the authors visualized air scintillation produced during a total skin irradiation treatment. Conclusions: Air scintillation can be measured to monitor a radiation beam in an inexpensive and nonperturbing manner. This physical phenomenon could be useful for dosimetry of therapeutic radiation beams or for online detection of gross errors during fractionated treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-G-BRF-09: Force- and Image-Adaptive Strategies for Robotised Placement of 4D Ultrasound Probes

Purpose: To allow continuous acquisition of high quality 4D ultrasound images for non-invasive live tracking of tumours for IGRT, image- and force-adaptive strategies for robotised placement of 4D ultrasound probes are developed and evaluated. Methods: The developed robotised ultrasound system is based on a 6-axes industrial robot (adept Viper s850) carrying a 4D ultrasound transducer with a mounted force-torque sensor. The force-adaptive placement strategies include probe position control using artificial potential fields and contact pressure regulation by a PD controller strategy. The basis for live target tracking is a continuous minimum contact pressure to ensure good image quality and high patient comfort. This contact pressure can be significantly disturbed by respiratory movements and has to be compensated. All measurements were performed on human subjects under realistic conditions. When performing cardiac ultrasound, rib- and lung shadows are a common source of interference and can disrupt the tracking. To ensure continuous tracking, these artefacts had to be detected to automatically realign the probe. The detection is realised by multiple algorithms based on entropy calculations as well as a determination of the image quality. Results: Through active contact pressure regulation it was possible to reduce the variance of the contact pressure by 89.79% despite respiratory motion of the chest. The results regarding the image processing clearly demonstrate the feasibility to detect image artefacts like rib shadows in real-time. Conclusion: In all cases, it was possible to stabilise the image quality by active contact pressure control and automatically detected image artefacts. This fact enables the possibility to compensate for such interferences by realigning the probe and thus continuously optimising the ultrasound images. This is a huge step towards fully automated transducer positioning and opens the possibility for stable target tracking in ultrasoundguided radiation therapy requiring contact pressure of 5–10 N. This work was supported by the Graduate School for Computing in Medicine and Life Sciences funded by Germany's Excellence Initiative [DFG GSC 235/1].

60 APPLIED LIFE SCIENCES↗

MO-DE-210-03: Ultrasound imaging is an attractive method for image guided radiation treatment (IGRT), by itself or to complement other imaging modalities

Ultrasound imaging is an attractive method for image guided radiation treatment (IGRT), by itself or to complement other imaging modalities. It is inexpensive, portable and provides good soft tissue contrast. For challenging soft tissue targets such as pancreatic cancer, ultrasound imaging can be used in combination with pre-treatment MRI and/or CT to transfer important anatomical features for target localization at time of treatment. The non-invasive and non-ionizing nature of ultrasound imaging is particularly powerful for intra-fraction localization and monitoring. Recognizing these advantages, efforts are being made to incorporate novel robotic approaches to position and manipulate the ultrasound probe during irradiation. These recent enabling developments hold potential to bring ultrasound imaging to a new level of IGRT applications. However, many challenges, not limited to image registration, robotic deployment, probe interference and image acquisition rate, need to be addressed to realize the full potential of IGRT with ultrasound imaging. Learning Objectives: Understand the benefits and limitations in using ultrasound to augment MRI and/or CT for motion monitoring during radiation therapy delivery. Understanding passive and active robotic approaches to implement ultrasound imaging for intra-fraction monitoring. Understand issues of probe interference with radiotherapy treatment. Understand the critical clinical workflow for effective and reproducible IGRT using ultrasound guidance. The work of X.L. is supported in part by Elekta; J.W. and K.D. is supported in part by a NIH grant R01 CA161613 and by Elekta; D.H. is support in part by a NIH grant R41 CA174089.

60 APPLIED LIFE SCIENCES↗