IMPLEMENTATION OF GENERALIZED INCORE DETECTOR RESPONSES IN MPACT
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Abstract not provided.
Abstract not provided.
Explore the source record for details and available documents.
Physical protection systems, and response forces in particular, are designed to prevent an adversary from successfully completing a malevolent act against a facility or transport operations. Timely detection and assessment of any potential adversary action against a target is an essential element of materials security. The timely detection and assessment must then be followed-up by a capable and timely response that might be enhanced with the additional situational awareness provided by unmanned aircraft systems (UAS). The United States Department of Energy’s National Nuclear Security Administration Office of International Nuclear Security has been exploring capabilities provided by UAS to support response force operations within the physical protection system. UAS have the potential to provide response force commanders and operators with situational awareness in assessing adversary locations and actions as well as the locations of responders. UAS may be utilized for area searches ahead of responder pathways to identify potential threats and to provide situational awareness of areas not normally covered by cameras (such as areas outside the fence line outside at fixed facilities). In addition, UAS can provide real-time information to transportation convoy teams that pass through constantly changing public access environments. This paper will provide operational recommendations to be addressed when integrating UAS into existing physical protection systems at fixed sites and during transport. Recommendations will include aspects of the following: needs analysis; tactics and techniques to support detection and assessment as well as response force deployment; remote pilot selection, qualifications, training, and currency; UAS selection criteria; UAS laws and regulations; possible cost sharing with other facility operations; and on-scene emergency management.
DOE Sponsored Material Identification and Surveillance (MIS) Program Review 28 Feb - 3 Mar 2023 SRS Bereket Kiflu
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The requirements for United States nuclear power plants to maintain a large onsite physical security force contribute to their large operational costs. The cost of maintaining the current physical security posture is approximately 10% of the overall operation and maintenance budget for commercial nuclear power plants. The goal of the Light Water Reactor Sustainability Program Physical Security Pathway is to develop tools, methods, and technologies and provide the technical basis for an optimized physical security posture. This pathway will analyze and minimize the conservatisms built into current security postures in order to reduce security costs while still ensuring adequate security and operational safety. The research performed at Idaho National Laboratory within this pathway has successfully developed a dynamic force-on-force (FOF) modeling framework using various computer simulation tools and integrated them with the dynamic assessment Event Modeling Risk Assessment using Linked Diagrams (EMRALD) tool. This document provides an overview of lessons learned in applying a dynamic computational framework that links results from a commercially available FOF simulation tool, a commercially available thermal-hydraulic tool, and EMRALD to an operating commercial nuclear power plant. This process of including plant procedures and multiple analysis results is being called Modeling and Analysis for Safety Security using Dynamic EMRALD Framework. Previous reports described how a user could integrate their plant-specific FOF models with the dynamic simulation tool EMRALD, model operator actions, integrate with probabilistic risk assessment tools, such as Computer Aided Fault Tree Analysis System or Systems Analysis Programs for Hands-on Integrated Reliability Evaluations, and with thermal-hydraulic tools, such as RELAP-5. Previous reports applied various combinations of available simulations codes with EMRALD using generic plant models to demonstrate how to perform the analysis. This report documents the results of applying the dynamic computational framework to an actual nuclear facility using their security scenarios and timelines. The purpose of this study was to verify that results achieved using generic models are similar to actual plant results and to refine our guidance of the use of the framework. Such an assessment enables further analysis, such as what-if scenarios and staff-reduction evaluation, thereby optimizing physical security at plants. NOTE: The work performed in this report is based on a generic EMRALD model with actual plant data used for the analysis. However, only the generic model and general results of the analysis are in the report. No plant’s sensitive information is discussed in this report. The discussion shows examples of insights that can be obtained from the MASS-DEF methodology.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
This work reports the first step in such an analysis, the verification of isotope removal capability for multi-region MSR depletion in Griffin. Verification studies are performed against SERPENT for chemical species removal from the core to an off-gas system for MSR analysis. A brief review of the Bateman equations including the isotopic removal term is provided along with a description of the example problem used in the verification studies performed in Griffin versus SERPENT. Next, the results of the verification study are presented for isotopic depletion, isotopic depletion with removal, and the specific analysis case of varying the solubility of Iodine in a salt system and how this can affect material buildup in the off-gas system. Lastly, the results are analyzed and future work detailing the fully coupled MSR depletion analysis that incorporates the true multiphysics of the system is discussed.
This presentation summarizes findings from three related studies: Evaluating Impacts of the Inflation Reduction Act and Bipartisan Infrastructure Law on the U.S. Power System; The Roles and Impacts of PV-Battery Hybrids in a Decarbonized U.S. Electricity Supply; and Optimal Design and Deployment of Wind-Solar Hybrids in Low-Carbon U.S. Power System. The compilation of results from these three studies indicate that the Inflation Reduction Act could drive significant deployment of variable renewable energy technologies, but the level of deployment depends on our ability to build new transmission projects (among other factors). Hybrid systems can help, to an extent, to facilitate greater shares of wind/solar with lesser amounts of transmission expansion.
The Distribution System Operator with Transactive (DSO+T) study conducted a large-scale simulation of over 60,000 customers in a region the size of Texas to demonstrate the effective coordination of distributed energy resources (DERs) in commercial and residential buildings. The integrated simulation included both the bulk (wholesale generation and transmission) and distribution systems. The DERs (including batteries, electric vehicles, air conditioning, and water heaters) participated in a transactive energy retail market that was integrated into an existing competitive wholesale market. The engineering and economic performance of the resulting demand flexibility was evaluated over annual simulations for both moderate and high renewable generation scenarios. A detailed parametric cost model was developed to enable detailed economic analysis of key stakeholders. In addition, fixed and dynamic customer tariffs were designed and applied to the customer population. This allowed the impact on annual customer bills to be analyzed for various building types (residential versus commercial; single- versus multi-family). This paper presents results showing the relative flexibility of batteries, electric vehicles, and building loads throughout the year and under different renewable scenarios. This feeds a detailed breakdown of the impact this flexibility has on the operating costs of the grid and the resulting net economic benefit. Finally, the study showed that practically all customer classes (including non-participating customers) save money under the proposed demand flexibility scheme. The study found overall net annual economic savings of $3.3-5.0B for a region the size of Texas equating to average customer bill savings of 10-16%.
The city of Frankfort, Kentucky is pursuing ambitious, affordable clean energy goals informed by NREL data and analysis.