Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “humidity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Evaporation from the Southern Ocean Estimated on the Basis of AIRS Satellite Data

Evaporation plays an important role in the global water and energy cycles and, hence, in climate change. Evaporation over the Southern Ocean, where the Antarctic sea ice coverage has a large annual cycle, is poorly quantified. In this study, daily evaporation is estimated for the Southern Ocean with a sea‐ice‐specific algorithm, using surface temperature and air humidity from National Aeronautics and Space Administration's Atmospheric Infrared Sounder (AIRS), and wind speeds from Modern‐Era Retrospective Analysis for Research and Applications, Version 2 (MERRA‐2), reanalysis during 2003–2016. An uncertainty of 34% was found in the evaporation product. The results indicate that annual evaporation has considerable interannual and regional variability, but with a decreasing trend during the study period over most of the Southern Ocean. There are, however, areas where evaporation has increased, specifically in the Ross Sea in winter and summer, with smaller positive trends in spring and fall. Overall, the changes in the difference between the surface specific humidity and the air specific humidity, and to a much lesser extent in the wind speed, are the main drivers for the changes in evaporation throughout the year. During spring and fall months, changes to the sea ice cover, which alter the surface specific humidity, are the main drivers for the change, but in summer and winter the main driver is the air‐specific humidity. Air masses originating from the Antarctic continent (south) are associated with cold and dry conditions, which increase evaporation, whereas air masses from lower latitudes in the Southern Ocean (north) are associated with warm and moist conditions, decreasing evaporation. Comparisons with other reanalysis evaporation products produce similar trends, although annual averages differ.

Boisvert, Linette↗

Statistical Analysis of Factors Riving Surface Ozone Variability over Continental South Africa

Statistical relationships between surface ozone (O3) concentration, precursor species and meteorological conditions in continental South Africa were examined from data obtained from measurement stations in north-eastern South Africa. Three multivariate statistical methods were applied in the investigation, i.e. multiple linear regression (MLR), principal component analysis (PCA) and –regression (PCR), and generalised additive model (GAM) analysis. The daily maximum 8-h moving average O3 concentrations were considered in these statistical models (dependent variable). MLR models indicated that meteorology and precursor species concentrations are able to explain ~50% of the variability in daily maximum O3 levels. MLR analysis revealed that atmospheric carbon monoxide (CO), temperature and relative humidity were the strongest factors affecting the daily O3 variability. In summer, daily O3 variances were mostly associated with relative humidity, while winter O3 levels were mostly linked to temperature and CO. PCA indicated that CO, temperature and relative humidity were not strongly collinear. GAM also identified CO, temperature and relative humidity as the strongest factors affecting the daily variation of O3. Partial residual plots found that temperature, radiation and nitrogen oxides most likely have a non-linear relationship with O3,while the relationship with relative humidity and CO is probably linear. An inter-comparison between O3 levels modelled with the three statistical models compared to measured O3 concentrations showed that the GAM model offered a slight improvement over the MLR model. These findings emphasise the critical role of regional-scale O3 precursors coupled with meteorological conditions in daily variances of O3 levels in continental South Africa.

multiple linear regression (MLR)↗

Impact of an SRA (hexylene glycol) on irreversible drying shrinkage and pore solution properties of cement pastes

Cementitious materials shrink when exposed to decreasing relative humidities, which may result in cracking. Shrinkage reducing admixtures (SRAs) can be used to reduce this drying shrinkage. Although many studies have shown that SRAs reduce the surface tension of the pore solution, the effects of SRAs on other pore solution properties and their relationship to drying shrinkage have been poorly characterized. In this work, we investigate the impact of an SRA (hexylene glycol) on the drying and re-humidification of a cement paste over an extended relative humidity range. The reduction in the first drying shrinkage by the SRA depends on relative humidity. The SRA also significantly reduces the irreversible drying shrinkage. We concluded that the SRA impacts drying shrinkage by acting on the capillary forces, by acting on the specific range of relative humidity over which those forces occur, and potentially by acting on the surface stresses through pore wall adsorption.

36 MATERIALS SCIENCE↗

Mass extinction efficiency and extinction hygroscopicity of ambient PM{sub 2.5} in urban China

The ambient PM{sub 2.5} pollution problem in China has drawn substantial international attentions. The mass extinction efficiency (MEE) and hygroscopicity factor (f(RH)) of PM{sub 2.5} can be readily applied to study the impacts on atmospheric visibility and climate. The few previous investigations in China only reported results from pilot studies and are lack of spatial representativeness. In this study, hourly average ambient PM{sub 2.5} mass concentration, relative humidity, and atmospheric visibility data from China national air quality and meteorological monitoring networks were retrieved and analyzed. It includes 24 major Chinese cities from nine city-clusters with the period of October 2013 to September 2014. Annual average extinction coefficient in urban China was 759.3±258.3 Mm{sup −1}, mainly caused by dry PM{sub 2.5} (305.8.2±131.0 Mm{sup −1}) and its hygroscopicity (414.6±188.1 Mm{sup −1}). High extinction coefficient values were resulted from both high ambient PM{sub 2.5} concentration (68.5±21.7 µg/m{sup 3}) and high relative humidity (69.7±8.6%). The PM{sub 2.5} mass extinction efficiency varied from 2.87 to 6.64 m{sup 2}/g with an average of 4.40±0.84 m{sup 2}/g. The average extinction hygroscopic factor f(RH=80%) was 2.63±0.45. The levels of PM{sub 2.5} mass extinction efficiency and hygroscopic factor in China were in comparable range with those found in developed countries in spite of the significant diversities among all 24 cities. Our findings help to establish quantitative relationship between ambient extinction coefficient (visual range) and PM{sub 2.5} & relative humidity. It will reduce the uncertainty of extinction coefficient estimation of ambient PM{sub 2.5} in urban China which is essential for the research of haze pollution and climate radiative forcing. - Highlights: • Data from air quality and meteorological monitoring networks were combined. • MEE and hygroscopicity of PM{sub 2.5} in China was similar to that of developed countries. • High extinction coefficient was dominated by both high PM{sub 2.5} and relative humidity.

54 ENVIRONMENTAL SCIENCES↗

Synthesis and reversible hydration behavior of the thiosulfate intercalated layered double hydroxide of Zn and Al

The thiosulfate-intercalated layered double hydroxide of Zn and Al undergoes reversible hydration with a variation in the relative humidity of the ambient. The hydrated and dehydrated phases, which represent the end members of the hydration cycle, both adopt the structure of the 3R{sub 1} polytype. In the intermediate range of relative humidity values (40–60%), the hydrated and dehydrated phases coexist. The end members of the hydration cycle adopt the structure of the same polytype, and vary only in their basal spacings. This points to the possibility that all the intermediate phases have a kinetic origin. - Graphical abstract: Basal spacing evolution of the thiosulfate ion intercalated [Zn–Al] LDH during one complete hydration–dehydration cycle as a function of relative humidity. Display Omitted - Highlights: • Thiosulfate intercalated [Zn–Al] LDHs were synthesized by co-precipitation. • The LDH exhibits reversible hydration with variation in humidity. • Both the end members of the hydration cycle adopt the same polytype structure. • The interstratified intermediates observed are kinetic in origin.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hybrid Polymer/Metal–Organic Framework Films for Colorimetric Water Sensing over a Wide Concentration Range [Hybrid Polymer/MOF Films for Colorimetric Water Sensing over a Wide Concentration Range]

Because of their extraordinary surface areas and tailorable porosity, metal–organic frameworks (MOFs) have the potential to be excellent sensors of gas-phase analytes. MOFs with open metal sites are particularly attractive for detecting Lewis basic atmospheric analytes, such as water. Here, we demonstrate that thin films of the MOF HKUST-1 can be used to quantitatively determine the relative humidity (RH) of air using a colorimetric approach. HKUST-1 thin films are spin-coated onto rigid or flexible substrates and are shown to quantitatively determine the RH within the range of 0.1–5% RH by either visual observation or a straightforward optical reflectivity measurement. At high humidity (>10% RH), a polymer/MOF bilayer is used to slow the transport of H 2 O to the MOF film, enabling quantitative determination of RH using time as the distinguishing metric. Lastly, the sensor is combined with an inexpensive light-emitting diode light source and Si photodiode detector to demonstrate a quantitative humidity detector for low humidity environments.

36 MATERIALS SCIENCE↗

Impact of Controlled Storage Conditions on the Hydrolysis and Surface Morphology of Amorphous-UO 3

The hydration and morphological effects of amorphous (A)-UO 3 following storage under varying temperature and relative humidity have been investigated. This study provides valuable insight into U-oxide speciation following aging, the U-oxide quantitative morphological data set, and, overall, the characterization of nuclear material provenance. A-UO 3 was synthesized via the washed uranyl peroxide synthetic route and aged based on a 3-factor circumscribed central composite design of experiment. Target aging times include 2.57, 7.00, 14.0, 21.0, and 25.4 days, temperatures of 5.51, 15.0, 30.0, 45.0, and 54.5 °C, and relative humidities of 14.2, 30.0, 55.0, 80.0, and 95.8% were examined. Following aging, crystallographic changes were quantified via powder X-ray diffraction and an internal standard Rietveld refinement method was used to confirm the hydration of A-UO 3 to crystalline schoepite phases. The particle morphology from scanning electron microscopy images was quantified using both the Morphological Analysis of MAterials software and machine learning. Results from the machine learning were processed via agglomerative hierarchical clustering analysis to distinguish trends in morphological attributes from the aging study. Significantly hydrated samples were found to have a much larger, plate-like morphology in comparison to the unaged controls. Predictive modeling via a response surface methodology determined that while aging time, temperature, and relative humidity all have a quantifiable effect on A-UO 3 crystallographic and morphological changes, relative humidity has the most significant impact.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Imaging of electrical response of NiO x under controlled environment with sub-25-nm resolution

The spatially resolved electrical response of rf-sputtered polycrystalline NiO x films composed of 40 nm crystallites was investigated under different relative humidity levels (RH). The topological and electrical properties (surface potential and resistance) were characterized using Kelvin probe force microscopy (KPFM) and conductive scanning probe microscopy at 0%, 50%, and 80% relative humidity with sub 25nm resolution. The surface potential of NiO x decreased by about 180 mV and resistance decreased in a nonlinear fashion by about 2 G when relative humidity was increased from 0% to 80%. The dimensionality of surface features obtained through autocorrelation analysis of topological, surface potential and resistance maps increased linearly with increased relative humidity as water was adsorbed onto the film surface. Spatially resolved surface potential and resistance of the NiO x films were found to be heterogeneous, with distinct features that grew in size from about 60 nm to 175 nm between 0% and 80% RH levels, respectively. Here, we find that the changes in the heterogeneous character of the NiO films are consistent through the topological, surface potential, and resistance measurements, suggesting that the nanoscale surface potential and resistance properties converge with the mesoscale properties as water is adsorbed onto the NiO x film.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Using Whole-House Field Tests to Empirically Derive Moisture Buffering Model Inputs

Building energy simulations can be used to predict a building's interior conditions, along with the energy use associated with keeping these conditions comfortable. These models simulate the loads on the building (e.g., internal gains, envelope heat transfer), determine the operation of the space conditioning equipment, and then calculate the building's temperature and humidity throughout the year. The indoor temperature and humidity are affected not only by the loads and the space conditioning equipment, but also by the capacitance of the building materials, which buffer changes in temperature and humidity. This research developed an empirical method to extract whole-house model inputs for use with a more accurate moisture capacitance model (the effective moisture penetration depth model). The experimental approach was to subject the materials in the house to a square-wave relative humidity profile, measure all of the moisture transfer terms (e.g., infiltration, air conditioner condensate) and calculate the only unmeasured term: the moisture absorption into the materials. After validating the method with laboratory measurements, we performed the tests in a field house. A least-squares fit of an analytical solution to the measured moisture absorption curves was used to determine the three independent model parameters representing the moisture buffering potential of this house and its furnishings. Follow on tests with realistic latent and sensible loads showed good agreement with the derived parameters, especially compared to the commonly-used effective capacitance approach. These results show that the EMPD model, once the inputs are known, is an accurate moisture buffering model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using Whole-House Field Tests to Empirically Derive Moisture Buffering Model Inputs

Building energy simulations can be used to predict a building's interior conditions, along with the energy use associated with keeping these conditions comfortable. These models simulate the loads on the building (e.g., internal gains, envelope heat transfer), determine the operation of the space conditioning equipment, and then calculate the building's temperature and humidity throughout the year. The indoor temperature and humidity are affected not only by the loads and the space conditioning equipment, but also by the capacitance of the building materials, which buffer changes in temperature and humidity. This research developed an empirical method to extract whole-house model inputs for use with a more accurate moisture capacitance model (the effective moisture penetration depth model). The experimental approach was to subject the materials in the house to a square-wave relative humidity profile, measure all of the moisture transfer terms (e.g., infiltration, air conditioner condensate) and calculate the only unmeasured term: the moisture absorption into the materials. After validating the method with laboratory measurements, we performed the tests in a field house. A least-squares fit of an analytical solution to the measured moisture absorption curves was used to determine the three independent model parameters representing the moisture buffering potential of this house and its furnishings. Follow on tests with realistic latent and sensible loads showed good agreement with the derived parameters, especially compared to the commonly-used effective capacitance approach. These results show that the EMPD model, once the inputs are known, is an accurate moisture buffering model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Surface Meteorology, Barrow, Alaska, Area A, B, C and D, Ongoing from 2012

Meteorological data are being collected at several points within four intensive study areas in Barrow. These data assist in the calculation of the energy balance at the land surface and are also useful as inputs into modeling activities. (https://doi.org/10.5440/1164893). Measurements at AREA A (all heights listed are relative to the land surface): Location of the Site A station: N71* 16.888', W156* 36.647' * Air temperature at three heights: 1.4 meters, 2.0 meters, 3.5 meters * Relative Humidity / Dew Point at two heights: 1.4 meters, 3.5 meters * Wind Speed at two heights: 1.3 meters, 3.5 meters * 4 Component Net Radiation @ 1.2 meters ** Upwelling & Downwelling Shortwave Radiation ** Upwelling & Downwelling Longwave Radiation * Summer Precipitation Site A is located on polygonal permafrost and co-located with continuous snow depth measurements and subsurface measurements. Measurements at AREA B (all heights listed are relative to the land surface): Location of the Site B station: N71* 16.785', W156* 36.211' * Air temperature at three heights: 1.4 meters, 2.0 meters, 3.5 meters * Relative Humidity / Dew Point at two heights: 1.4 meters, 3.5 meters * Wind Speed at two heights: 1.3 meters, 3.5 meters * 4 Component Net Radiation @ 1.2 meters ** Upwelling & Downwelling Shortwave Radiation ** Upwelling & Downwelling Longwave Radiation * Summer Precipitation Site B is located on polygonal permafrost and co-located with continuous snow depth measurements and subsurface measurements. ------------------------------------------------- Measurements at AREA C (all heights listed are relative to the land surface): Location of the Site C station: N71* 16.804', W156* 36.072' * Air temperature at three heights: 1.4 meters, 2.0 meters, 3.5 meters * Relative Humidity / Dew Point at two heights: 1.4 meters, 3.5 meters * Wind Speed at two heights: 1.3 meters, 3.5 meters * 4 Component Net Radiation @ 1.2 meters ** Upwelling & Downwelling Shortwave Radiation ** Upwelling & Downwelling Longwave Radiation * Summer Precipitation * Barometric Pressure Site C is located on polygonal permafrost and co-located with continuous snow depth measurements and subsurface measurements. ------------------------------------------------- Measurements at AREA D (all heights listed are relative to the land surface): Location of the Site D station: N71* 16.927', W156* 36.036' * Air temperature at one height: 1.2 meters * Relative Humidity / Dew Point at one height: 1.2 * Wind Speed at one height: 1.2 meters * 4 Component Net Radiation @ 1.0 meters ** Upwelling & Downwelling Shortwave Radiation ** Upwelling & Downwelling Longwave Radiation Site D is located on polygonal permafrost and co-located with continuous snow depth measurements and subsurface measurements. Data are in ASCII files, with columns separated by commas: ','

54 ENVIRONMENTAL SCIENCES↗

US NRC-Sponsored Research on Stress Corrosion Cracking Susceptibility of Dry Storage Canister Materials in Marine Environments - 13344

At a number of locations in the U.S., spent nuclear fuel (SNF) is maintained at independent spent fuel storage installations (ISFSIs). These ISFSIs, which include operating and decommissioned reactor sites, Department of Energy facilities in Idaho, and others, are licensed by the U.S. Nuclear Regulatory Commission (NRC) under Title 10 of the Code of Federal Regulations, Part 72. The SNF is stored in dry cask storage systems, which most commonly consist of a welded austenitic stainless steel canister within a larger concrete vault or overpack vented to the external atmosphere to allow airflow for cooling. Some ISFSIs are located in marine environments where there may be high concentrations of airborne chloride salts. If salts were to deposit on the canisters via the external vents, a chloride-rich brine could form by deliquescence. Austenitic stainless steels are susceptible to chloride-induced stress corrosion cracking (SCC), particularly in the presence of residual tensile stresses from welding or other fabrication processes. SCC could allow helium to leak out of a canister if the wall is breached or otherwise compromise its structural integrity. There is currently limited understanding of the conditions that will affect the SCC susceptibility of austenitic stainless steel exposed to marine salts. NRC previously conducted a scoping study of this phenomenon, reported in NUREG/CR-7030 in 2010. Given apparent conservatisms and limitations in this study, NRC has sponsored a follow-on research program to more systematically investigate various factors that may affect SCC including temperature, humidity, salt concentration, and stress level. The activities within this research program include: (1) measurement of relative humidity (RH) for deliquescence of sea salt, (2) SCC testing within the range of natural absolute humidity, (3) SCC testing at elevated temperatures, (4) SCC testing at high humidity conditions, and (5) SCC testing with various applied stresses. Results to date indicate that the deliquescence RH for sea salt is close to that of MgCl{sub 2} pure salt. SCC is observed between 35 and 80 deg. C when the ambient (RH) is close to or higher than this level, even for a low surface salt concentration. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Treatment of radioactive liquid waste by the forced-air exhaust system - 15190

A Natural Evaporation Facility (NEF) was constructed to treat low level (LL) radioactive liquid waste arising from a Radioactive Waste Treatment Facility (RWTF) at the Korea Atomic Energy Research Institute (KAERI). In order to process LL radioactive liquid waste, we investigated the influence of climate condition, mainly atmospheric humidity and temperature, on the amount of evaporation in a forced-air exhaust system in KAERI. Evaporation media were made of cotton and polyester. Air exhaust in the facility was forced by exhaust fans. The evaporation rate and the decontamination factor were calculated and reported as shown in the results section. The evaporation and air supply flow increased at the same rate. In addition, the liquid waste feed rate and temperature of supplied air increased. Regarding the relative humidity of supplied air, the evaporation rate increased as the relative humidity decreased. As the result of this study, the operating conditions for the NEF were optimized in the following areas: The air temperature above 8 deg. C, the air relative humidity below 70%, the air flow rate 1.14-1.47 m/sec, and the liquid waste feed rate 4.6 l/hr.m{sup 2}. The decontamination factor was 1.1x10{sup 3}. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Material Properties of Aged Rigid Polyurethane Foam

Foams are classified as either rigid or flexible and are commonly used in applications such as pipe insulation, carpet fibers, and chair foam cushions. Polyurethane foams are excellent thermal insulators, have excellent mechanical properties, and are chemically inert. With the addition of fire protective additives, polyurethane foams have the ability to intumescence when exposed to high temperatures. For the future storage of the 9977 nuclear shipping packages, the material properties of the General Plastics 3716 rigid polyurethane foam were evaluated for long term performance by comparing aged samples to unaged samples. General Plastics 3716 rigid polyurethane foam was aged from November 2014 to June 2019 at varying temperatures of: 160 deg. F, 160 deg. F + 50% relative humidity (RH), 185 deg. F, 215 deg. F, and 250 deg. F. The foam was then analyzed via Fourier Transform Infrared Spectroscopy (FTIR), 3D Optical Microscope, Thermal Gravimetric Analysis (TGA), Differential Scanning Calorimetry (DSC). FTIR and Optical Microscope: No significant change to chemical or physical structure was evident by FTIR or optical microscope analysis. DSC: Decrease of heat capacity over time for all oven temperatures except a slight increase for the 185 deg. F conditioned foams. Largest decrease evident with foams conditioned at 250 deg. F. A slight increase in heat capacity for humid samples. Similar trends in heat capacities at 71 deg. C and 102 deg. C. TGA: As conditioning temperature increased, a decline was evident in the average percent weight loss, onset temperature, and first derivative peak temperature. No significant effect due to humidity except for a decrease in first derivative peak temperature. Unaged samples exhibited strong intumescence. Foams conditioned at 160 deg. F exhibited slight intumescence. Results suggest fire protective additives decomposed at higher temperatures, which contributed to a lower average percent mass loss in higher temperature conditioning. Further thermal degradation testing would be beneficial to evaluate the ability of the conditioned foams to intumesce. Evaluate irradiation dose rate effects on conditioned foam. Possible conditioning in an environment with a known humidity or analyzing a new aliquot of sample for each trial to achieve a more representative heat capacity calculation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The influence of water table depth and the free atmospheric state on convective rainfall predisposition

Here, we report a mechanistic model for the soil-plant system is coupled to a conventional slab representation of the atmospheric boundary layer (ABL) to explore the role of groundwater table (WT) variations and free atmospheric (FA) states on convective rainfall predisposition (CRP) at a Loblolly pine plantation site situated in the lower coastal plain of North Carolina. Predisposition is quantified using the crossing between modeled lifting condensation level (LCL) and convectively grown ABL depth. The LCL-ABL depth crossing is necessary for air saturation but not sufficient for cloud formation and subsequent convective rainfall occurrence. However, such crossing forms the main template for which all subsequent dynamical processes regulating the formation (or suppression) of convective rainfall operate on. If the feedback between surface fluxes and FA conditions is neglected, a reduction in latent heat flux associated with reduced WT levels is shown to enhance the ABL-LCL crossing probability. When the soil-plant system is fully coupled with ABL dynamics thereby allowing feedback with ABL temperature and humidity, FA states remain the leading control on CRP. However, vegetation water stress plays a role in controlling ABL-LCL crossing when the humidity supply by the FA is within an intermediate range of values. When FA humidity supply is low, cloud formation is suppressed independent of surface latent heat flux. Similarly, when FA moisture supply is high, cloud formation can occur independent of surface latent heat flux. In an intermediate regime of FA moisture supply, the surface latent heat flux controlled by soil water availability can supplement (or suppress) the necessary water vapor leading to reduced LCL and subsequent ABL-LCL crossing. Lastly, it is shown that this intermediate state corresponds to FA values around the mode in observed humidity lapse rates γ w (between -2.5 × 10 -6 and -1.5 × 10 -6 kg kg -1 m -1 ), suggesting that vegetation water uptake may be controlling CRP at the study site.

54 ENVIRONMENTAL SCIENCES↗

Kinetic Effects on Self-Assembly and Function of Protein-Polymer Bioconjugates in Thin Films Prepared by Flow Coating

The self-assembly of nanostructured globular protein arrays in thin films is demonstrated using protein–polymer block copolymers based on a model protein mCherry and the polymer poly(oligoethylene glycol acrylate) (POEGA). Conjugates are flow coated into thin films on a poly(ethylene oxide) grafted Si surface, forming self-assembled cylindrical nanostructures with POEGA domains selectively segregating to the air–film interface. Long-range order and preferential arrangement of parallel cylinders templated by selective surfaces are demonstrated by controlling relative humidity. Long-range order increases with coating speed when the film thicknesses are kept constant, due to reduced nucleation per unit area of drying film. Fluorescence emission spectra of mCherry in films prepared at <25% relative humidity shows a small shift suggesting that proteins are more perturbed at low humidity than high humidity or the solution state.

36 MATERIALS SCIENCE↗

Performance and durability of electrically conductive tape for shingled Si heterojunction technology cells

We report electrically conductive tape (ECT) was characterized and used to assemble shingled cell strings at low temperature to achieve high reliability Pb- and Ag-free interconnections. The volume resistivity for two considered ECTs are 0.13 ± 0.06 mΩ·cm and 0.47 ± 0.20 mΩ·cm and specific contact resistances, 6.85± 2.00 mΩ·cm 2 and 6.30 ± 0.37 mΩ·cm 2 using the emerging IEC 62788-8-1 Technical Specification for assessment of electrically conductive adhesives (ECA). Durability and performance of the technology in glass–glass mini modules were evaluated with temperature cycling, damp heat testing, and combined-accelerated stress testing (CAST). Through temperature cycling (-40°C to 85°C) applying five times the mini module short-circuit current in forward bias and in the multi climate CAST protocol, there was negligible degradation of fill factor after replacing connectors at the modules' cable leads; however, CAST resulted in short circuit current loss attributed to degradation in light collection by the cells, not the ECT. The IEC 61215-2 85°C, 85% relative humidity damp heat testing showed susceptibility of the HJT cells to effects of humidity in the electroluminescence intensity around the module perimeter that degraded power performance by 4% (relative). Contrasting the IEC 61215-2 qualification testing-based damp heat testing with CAST, factors such as the optical stress of CAST may precipitate the degradation of the modules whereas the humidity levels and duration of IEC 61215-2 damp heat testing may lead to excessive levels of humidity diffused into the modules, potentially resulting in degradation that is unrepresentative of the field.

14 SOLAR ENERGY↗

Daily grass reference evapotranspiration with Meteosat Second Generation shortwave radiation and reference ET products

Here we assess the accuracy of estimating daily grass reference evapotranspiration (PM-ET o ) using daily shortwave radiation (R s ) and reference evapotranspiration (ET REF ) products provided by the Meteosat Second Generation (MSG) geostationary satellite delivered by the Satellite Applications Facility on Land Surface Analysis (LSA-SAF) framework. The accuracy of using reanalysis ERA5 shortwave radiation data (R s ERA5 ) provided by the European Center for Medium-Range Weather Forecasts (ECMWF) is also evaluated. The assessments were performed using observed weather variables at 37 weather stations distributed across continental Portugal, where climate conditions range from semi-arid to humid, and 12 weather stations located in Azores islands, characterized by humid, windy and often cloudy conditions. This study&#x27;s use of data from a variety of climate conditions contributed to a unique and innovative assessment of the usability of LSA-SAF and ERA5 products for ET o estimation. The first assessment focused on comparing LSA-SAF estimates of R s (R s LSA-SAF ) against ground stations (R s ground ). The results showed a good matching between the two R s data sets for continental Portugal but a tendency for R s LSA-SAF to under-estimate R s ground in the cloudy islands of Azores. ET o values computed using R s LSA-SAF data and observed temperature, humidity and wind speed (ET o LSA-SAF ) were then compared with PM-ET o estimates with ground-based data, which were used as benchmark; input data of temperature and humidity needed for PM-ET o were quality checked for surface aridity effects. It was observed that ET o LSA-SAF is strongly correlated with PM-ET o (R 2 > 0.97) for most locations in continental Portugal, with regression coefficient of a linear regression forced to the origin ranging between 0.95 and 1.05, mean root mean square error (RMSE) of 0.13 mm d –1 , and Nash and Sutcliff efficiency of modeling (EF) above 0.95. For most Azores locations, ET o LSA-SAF over-estimated PM-ET o . This is likely a consequence of the high spatio-temporal heterogeneity of weather conditions that occur in these oceanic islands together with the different footprints of satellite (averaged over the pixel) and station observations. Reanalysis ERA5 shortwave radiation data presented similar behavior to the LSA-SAF products, however with slightly lower accuracy. The daily LSA-SAF ET REF product (ET REF LSA-SAF ) was assessed and results have shown a good accuracy of this product, with acceptable RMSE and high EF values, for continental Portugal but a low accuracy for the Azores islands. A simplified bias correction approach was shown to improve both ET o derived from the LSA-SAF products, namely for Azores stations, which seem to be representative of smaller areas. The use of the FAO-PM temperature approach (PMT) was also assessed using the R s LSA-SAF and R s ERA5 data, which showed a superiority of the LSA-SAF product for ET o estimations (ET o PMT LSA-SAF ). No significant differences (p < 0.05) were observed in terms of the median value of the RMSE when adopting ET o PMT and ET REF LSA-SAF . Differently, results showed that using the R s LSA-SAF in the PMT approach (ET o PMT LSA-SAF ) produces significantly better RMSE results than ET o PMT and ET REF LSA-SAF . Overall, the performed assessment allows concluding that the use of R s LSA-SAF, and to a lesser extent the use of the R s ERA5 , highly improves the accuracy of computation of ET o when R s observations are not available, including when only temperature data are accessible. The use of the ET REF LSA-SAF product is a good alternative when observed weather data are not available.

54 ENVIRONMENTAL SCIENCES↗