Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “guide”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Photoperiodic Flower Mimicking Metallic Nanoparticles for Image-Guided Medicine Applications

To enhance localization and precision of therapeutic radiation delivery, nano-radiosensitizers have been developed. A specific volume of comprising surface atoms is known to be the radiosensitizing region. However, the shape dependent local dose enhancement of nanoparticles is often underestimated and rarely reported. Here, a noble metal nanostructure, inspired by the photoperiodic day-flowers, was synthesized by metal reduction with bile acid molecules. The impact of high surface area of day-flower like nanoparticles (D-NP) on radiosensitizing effect was demonstrated with assays for ROS generation, cellular apoptosis, and clonogenic survival of human liver cancer cells (HepG2) cells. In comparison with lower surface area spherical night-flower like nanoparticles (N-NP), exposure of our D-NP to external beam radiation doses led to a significant increase in reactive oxygen species (ROS) production and radiosensitizing cell cycle synchronization, resulting in enhanced cancer cell killing effect. In clonogenic survival studies, dose enhancing factor (DEF) of D-NP was 16.5-fold higher than N-NP. Lastly, we demonstrated in vivo feasibility of our D-NP as a potent nano-radiosensitizer and CT contrast agent for advanced image guided radiation therapy.

60 APPLIED LIFE SCIENCES↗

Structure-Guided Design and Procognitive Assessment of a Potent and Selective Phosphodiesterase 2A Inhibitor

In this paper we describe the development of a series of pyrazolopyrimidinone phosphodiesterase 2A (PDE2) inhibitors using structure-guided lead identification and design. The series was derived from informed chemotype replacement based on previously identified internal leads. The initially designed compound 3, while potent on PDE2, displayed unsatisfactory selectivity against the other PDE2 isoforms. Compound 3 was subsequently optimized for improved PDE2 activity and isoform selectivity. Insights into the origins of PDE2 selectivity are described and verified using cocrystallography. An optimized lead, 4, demonstrated improved performance in both a rodent and a nonhuman primate cognition model.

60 APPLIED LIFE SCIENCES↗

Train, Inform, Borrow, or Combine? Approaches to Process–Guided Deep Learning for Groundwater–Influenced Stream Temperature Prediction

Although groundwater discharge is a critical stream temperature control process, it is not explicitly represented in many stream temperature models, an omission that may reduce predictive accuracy, hinder management of aquatic habitat, and decrease user confidence. We assessed the performance of a previously-described process-guided deep learning model of stream temperature in the Delaware River Basin (USA). We found lower accuracy (root mean square error [RMSE] of 1.71 versus 1.35°C) and stronger seasonal bias (absolute mean monthly bias of 1.06 vs. 0.68°C) for reaches primarily influenced by deep groundwater as compared to atmospheric conditions. We then tested four approaches for improving groundwater process representation: (a) a custom loss function leveraging the unique patterns of air and water temperature coupling characteristic of different temperature drivers, (b) inclusion of additional groundwater-relevant catchment attributes, (c) incorporation of additional process model outputs, and (d) a composite model. The custom loss function and the additional attributes significantly improved the predictive accuracy in groundwater-dominated reaches (RMSE of 1.37 and 1.26°C) and reduced the seasonal bias (absolute mean monthly bias of 0.44 and 0.48°C), but neither approach could identify holdout groundwater reaches. Variable importance analysis indicates the custom loss function nudges the model to use the existing inputs more efficiently, whereas with the added features the model relies on a broader suite of inputs. This analysis is a substantial step toward more accurately representing groundwater discharge processes in stream temperature models and will improve predictive accuracy and inform habitat management.

54 ENVIRONMENTAL SCIENCES↗

A guided ion beam investigation of UO 2 + thermodynamics and f orbital participation: Reactions of U + + CO 2 , UO + + O 2 , and UO + + CO

A guided ion beam tandem mass spectrometer was employed to study the reactions of U + + CO 2 , UO + + O 2 , and the reverse of the former, UO + + CO. Reaction cross sections as a function of kinetic energy over about a three order of magnitude range were studied for all systems. The reaction of U + + CO 2 proceeds to form UO + + CO with an efficiency of 118% ± 24% as well as generating UO 2 + + C and UCO + + O. The reaction of UO + + O 2 forms UO 2 + in an exothermic, barrierless process and also results in the collision-induced dissociation of UO + to yield U + . In the UO + + CO reaction, the formation of UO 2 + in an endothermic process is the dominant reaction, but minor products of UCO + + O and U + + (O + CO) are also observed. Analysis of the kinetic energy dependences observed provides the bond energies, D 0 (U + –O) = 7.98 ± 0.22 and 8.05 ± 0.14 eV, D 0 (U + –CO) = 0.73 ± 0.13 eV, and D 0 (OU + –O) = 7.56 ± 0.12 eV. The values obtained for D 0 (U + –O) and D 0 (OU + –O) agree well with the previously reported literature values. To our knowledge, this is the first experimental measurement of D 0 (U + –CO). Furthermore, an analysis of the oxide bond energies shows that participation of 5f orbitals leads to a substantial increase in the thermodynamic stability of UO 2 + relative to ThO 2 + and especially transition metal dioxide cations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The bond energy of UN + : Guided ion beam studies of the reactions of U + with N 2 and NO

In this work, a guided ion beam tandem mass spectrometer was used to study the reactions of U + with N 2 and NO. Reaction cross sections were measured over a wide range of energy for both systems. In each reaction, UN + is formed by an endothermic process, thereby enabling the direct measurement of the threshold energy and determination of the UN + bond dissociation energy. For the reaction of U + + N 2 , a threshold energy (E 0 ) of 4.02 ± 0.11 eV was measured, leading to D 0 (UN + ) = 5.73 ± 0.11 eV. The reaction of U + + NO yields UO + through an exothermic, barrierless process that proceeds with 94 ± 23% efficiency at the lowest energy. Analysis of the endothermic UN + cross section in this reaction provides E 0 = 0.72 ± 0.11 eV and, therefore, D 0 (UN + ) = 5.78 ± 0.11 eV. Averaging the values obtained from both reactions, we report D 0 (UN + ) = 5.76 ± 0.13 eV as our best value (uncertainty of two standard deviations). Combined with precise literature values for the ionization energies of U and UN, we also derive D 0 (UN) = 5.86 ± 0.13 eV. Both bond dissociation energies agree well with high-level theoretical treatments in the literature. The formation of UN + in reaction of U + with NO also exhibits a considerable increase in reaction probability above ~3 eV. Theory suggests that this may be consistent with the formation of UN + in excited quintet spin states, which we hypothesize are dynamically favored because the number of 5f electrons in reactants and products is conserved.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Numerical assessment of the impact of the guiding-centre approximation on fast ion simulations in NSTX

Guiding-centre (GC) and full-orbit (FO) simulations of the beam-injected fast ion distribution and the corresponding neutron emissivity have been carried out for magnetohydrodynamics-quiescent National Spherical Torus eXperiment (NSTX) plasmas, using a combination of ASCOT5 and DRESS, to assess the suitability of the GC approximation for fast ions in NSTX. It was found that GC and FO simulations predicted substantially different steady-state distributions in both position and velocity space and different neutron emissivity profiles, leading to a 15% reduction in the predicted global neutron rate for FO relative to GC. These changes accompany a higher magnetic moment in FO, and correspond to a change in particle orbits from co-passing to trapped and stagnation orbits. ASCOT5 was also benchmarked against TRANSP/NUBEAM with input loaded entirely from TRANSP/NUBEAM output files, with agreement found between the GC simulations when finite Larmor radius (FLR) corrections were omitted. ASCOT5 FO and TRANSP/NUBEAM with FLR produced fast ion distributions which differed in localised regions, but predicted global neutron rates which agree within 3%.

ASCOT↗

Heritable, multinucleotide deletions in plants using viral delivery of a repair exonuclease and guide RNAs

Abstract CRISPR/Cas9-mediated mutagenesis typically results in short insertion/deletion mutations, which are often too small to disrupt the function of cis-acting regulatory elements. Here, we describe a highly efficient in planta gene editing approach called VirTREX2-HLDel that achieves heritable multinucleotide deletions in both protein-coding genes and noncoding DNA regulatory elements. VirTREX2-HLDel uses RNA viruses to deliver both the 3 prime repair exonuclease 2 (TREX2) and single-guide RNAs. Our method enables recovery of multiplexed heritable deletions and increases the heritable gene editing frequency at poorly edited sites. We identified functional conservation and divergence of MICRORNA164 (miR164) in Nicotiana benthamiana and tomato (Solanum lycopersicum) using VirTREX2-HLDel and observed previously uncharacterized phenotypes in plants with large deletions at this locus. Our viral delivery method reduces the need for tissue culture and will accelerate the understanding of protein-coding and regulatory regions in plants.

59 BASIC BIOLOGICAL SCIENCES↗

Physics-Guided Machine Learning for Prediction of Cloud Properties in Satellite-Derived Solar Data

With over 20 years of high-resolution surface irradiance data covering most of the western hemisphere, the National Solar Radiation Database (NSRDB) is a vital public data asset. The NSRDB uses a two-step Physical Solar Model (PSM) that explicitly considers the effects of clouds and other atmospheric variables on radiative transfer. High-quality physical and optical cloud properties derived from satellite imagery are perhaps the most important data inputs to the PSM, representing the greatest source of radiation attenuation and scattering. However, traditional methods for cloud property retrieval have their own limitations and are unable to accurately predict cloud properties outside of nominal conditions. We introduce a physics-guided neural network that can accurately predict cloud properties when traditional methods fail or are inaccurate. Using this framework, we show reductions in relative Root Mean Square Error (RMSE) for Global Horizontal Irradiance (GHI) up to 13 percentage points for timesteps that previously had missing or low-quality cloud property data. We expect that this methodology will be effective in improving the quality of cloud property and solar irradiance data in the NSRDB.

cloud properties↗

Multi‐Decadal Dynamics of Wetland Methane Emissions Revealed by Knowledge‐Guided Machine Learning

Measurement of methane fluxes (FCH 4 ) from natural systems, such as wetlands, has lagged far behind carbon dioxide fluxes. Short and fragmented wetland FCH 4 data limit our ability to assess its long-term dynamics and potential climate feedbacks. Extrapolating short-term FCH 4 records to recent decades remains challenging for both process-based models and data-driven machine learning (ML) approaches. Here, we develop a knowledge-guided ML framework that integrates eddy covariance (EC) FCH 4 observations, field warming experiments, and biogeochemical knowledge to reconstruct the long-term FCH 4 budgets and trends. Focusing on the 11 longest EC monitoring sites in the AmeriFlux network, we found considerable variability in multi-decadal trends of wetland FCH 4 , with increases up to 14% per decade from 2000 to 2024. We also found that the strength of these increasing trends declines from high to low latitudes, highlighting the vulnerability of northern wetlands. This work presents novel and robust reconstructions of long-term wetland FCH 4 , offering critical benchmark datasets for bottom-up ecosystem models and advancing fundamental understanding of wetland biogeochemistry.

AmeriFlux site↗

Nondestructive Evaluation of Stress Corrosion Cracking in a Welded Steel Plate Using Guided Ultrasonic Waves

Stress corrosion cracking (SCC) had occurred in early-generation high-level nuclear waste tanks constructed by welding carbon steel. This paper describes an ultrasonic inspection system and its fundamental ability to detect and quantify the length of SCC on thick welded steel plates. The finite element method (FEM) was applied to simulate the welding process to estimate the welding residual stress field. Growth of stress corrosion cracks is driven by crack stress intensities exceeding the subcritical cracking threshold intensity. The subject plate was experimentally inspected with ultrasonic nondestructive evaluation (NDE) techniques to characterize the extent of SCC. The NDE system uses a piezoelectric transducer to generate guided waves in the thick steel plate, and a scanning laser Doppler vibrometer (SLDV) to measure multidimensional time–space wavefield data over a user-defined scanning area in the plate surface. The measured wavefield data can show wave interactions in a localized area in the plate due to the presence of the discontinuities of the SCC. To generate an inspection image that can precisely show the crack’s location and/or the dimension, the wavefield data are further processed to generate inspection image that maps the entire sample plate so the crack can be clearly identified in the plate while its length can be readily estimated. In conclusion, the ultrasonic test results for crack length agree well with the visually estimated length and are close to that predicted by the FEM for cracks in the weld residual stress field.

36 MATERIALS SCIENCE↗

SU-E-J-88: Margin Reduction of Level II/III Planning Target Volume for Image-Guided Simultaneous Integrated Boost Head-And-Neck Treatment

Purpose: To investigate the feasibility of improved normal tissue sparing for head-and-neck (H'N) image-guided radiotherapy (IGRT) by employing tighter CTV-to-PTV margins for target level II/III though a GPU-based deformable image registration and dose accumulation framework. Methods: Ten H'N simultaneous integrated boost cases treated on TomoTherapy were retrospectively analyzed. Weekly kVCT scans in addition to daily MVCT scans were acquired for each patient. Reduced margin plans were generated with 0- mm margin for level II and III PTV (while 3-5 mm margin for PTV1) and compared with the standard margin plan using 3-5mm margin to all CTV1-3 (reference plan). An in-house developed GPU-based 3D image deformation tool was used to register and deform the weekly KVCTs with the planning CT and determine the delivered mean/minimum/maximum dose, dose volume histograms (DVHs), etc. Results: Compared with the reference plans, the averaged cord maximum, the right and left parotid doses reduced by 22.7 %, 16.5 %, and 9 % respectively in the reduced margin plans. The V95 for PTV2 and PTV3 were found within 2 and 5% between the reference and tighter margin plans. For the reduced margin plans, the averaged cumulative mean doses were consistent with the planned dose for PTV1, PTV2 and PTV3 within 1.5%, 1.7% and 1.4%. Similar dose variations of the delivered dose were seen for the reference and tighter margin plans. The delivered maximum and mean doses for the cord were 3.55 % and 2.37% higher than the planned doses; a 5 % higher cumulative mean dose for the parotids was also observed for the delivered dose than the planned doses in both plans. Conclusion: By imposing tighter CTV-to-PTV margins for level II and III targets for H'N irradiation, acceptable cumulative doses were achievable when coupled with weekly kVCT guidance while improving normal structure sparing.

60 APPLIED LIFE SCIENCES↗

SU-E-J-205: Monte Carlo Modeling of Ultrasound Probes for Real-Time Ultrasound Image-Guided Radiotherapy

Purpose: To quantify the effect of ultrasound (US) probe beam attenuation for radiation therapy delivered under real-time US image guidance by means of Monte Carlo (MC) simulations. Methods: MC models of two Philips US probes, an X6-1 matrix-array transducer and a C5-2 curved-array transducer, were built based on their CT images in the EGSnrc BEAMnrc and DOSXYZnrc codes. Due to the metal parts, the probes were scanned in a Tomotherapy machine with a 3.5 MV beam. Mass densities in the probes were assigned based on an electron density calibration phantom consisting of cylinders with mass densities between 0.2–8.0 g/cm{sup 3}. Beam attenuation due to the probes was measured in a solid water phantom for a 6 MV and 15 MV 15x15 cm{sup 2} beam delivered on a Varian Trilogy linear accelerator. The dose was measured with the PTW-729 ionization chamber array at two depths and compared to MC simulations. The extreme case beam attenuation expected in robotic US image guided radiotherapy for probes in upright position was quantified by means of MC simulations. Results: The 3.5 MV CT number to mass density calibration curve was found to be linear with R{sup 2} > 0.99. The maximum mass densities were 4.6 and 4.2 g/cm{sup 3} in the C5-2 and X6-1 probe, respectively. Gamma analysis of the simulated and measured doses revealed that over 98% of measurement points passed the 3%/3mm criteria for both probes and measurement depths. The extreme attenuation for probes in upright position was found to be 25% and 31% for the C5-2 and X6-1 probe, respectively, for both 6 and 15 MV beams at 10 cm depth. Conclusion: MC models of two US probes used for real-time image guidance during radiotherapy have been built. As a Result, radiotherapy treatment planning with the imaging probes in place can now be performed. J Schlosser is an employee of SoniTrack Systems, Inc. D Hristov has financial interest in SoniTrack Systems, Inc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo modeling of ultrasound probes for image guided radiotherapy

Purpose: To build Monte Carlo (MC) models of two ultrasound (US) probes and to quantify the effect of beam attenuation due to the US probes for radiation therapy delivered under real-time US image guidance. Methods: MC models of two Philips US probes, an X6-1 matrix-array transducer and a C5-2 curved-array transducer, were built based on their megavoltage (MV) CT images acquired in a Tomotherapy machine with a 3.5 MV beam in the EGSnrc, BEAMnrc, and DOSXYZnrc codes. Mass densities in the probes were assigned based on an electron density calibration phantom consisting of cylinders with mass densities between 0.2 and 8.0 g/cm{sup 3}. Beam attenuation due to the US probes in horizontal (for both probes) and vertical (for the X6-1 probe) orientation was measured in a solid water phantom for 6 and 15 MV (15 × 15) cm{sup 2} beams with a 2D ionization chamber array and radiographic films at 5 cm depth. The MC models of the US probes were validated by comparison of the measured dose distributions and dose distributions predicted by MC. Attenuation of depth dose in the (15 × 15) cm{sup 2} beams and small circular beams due to the presence of the probes was assessed by means of MC simulations. Results: The 3.5 MV CT number to mass density calibration curve was found to be linear with R{sup 2} > 0.99. The maximum mass densities in the X6-1 and C5-2 probes were found to be 4.8 and 5.2 g/cm{sup 3}, respectively. Dose profile differences between MC simulations and measurements of less than 3% for US probes in horizontal orientation were found, with the exception of the penumbra region. The largest 6% dose difference was observed in dose profiles of the X6-1 probe placed in vertical orientation, which was attributed to inadequate modeling of the probe cable. Gamma analysis of the simulated and measured doses showed that over 96% of measurement points passed the 3%/3 mm criteria for both probes placed in horizontal orientation and for the X6-1 probe in vertical orientation. The X6-1 probe in vertical orientation caused the highest attenuation of the 6 and 15 MV beams, which at 10 cm depth accounted for 33% and 43% decrease compared to the respective (15 × 15) cm{sup 2} open fields. The C5-2 probe in horizontal orientation, on the other hand, caused a dose increase of 10% and 53% for the 6 and 15 MV beams, respectively, in the buildup region at 0.5 cm depth. For the X6-1 probe in vertical orientation, the dose at 5 cm depth for the 3-cm diameter 6 MV and 5-cm diameter 15 MV beams was attenuated compared to the corresponding open fields to a greater degree by 65% and 43%, respectively. Conclusions: MC models of two US probes used for real-time image guidance during radiotherapy have been built. Due to the high beam attenuation of the US probes, the authors generally recommend avoiding delivery of treatment beams that intersect the probe. However, the presented MC models can be effectively integrated into US-guided radiotherapy treatment planning in cases for which beam avoidance is not practical due to anatomy geometry.

60 APPLIED LIFE SCIENCES↗

TU-E-TOUR-T-00: Exhibit Hall Guided Tours-Microdosimeters for Therapy (Tuesday)

Tour Leader: Indra Das, NYU Langone Medical Center, New York, NY Tour Guides: Hsui Ai, Indiana University School of Medicine, Indianapolis, IN Aaron Andersen, Indiana University School of Medicine, Indianapolis, IN Olga Volotoskova, NYU Langone Medical Center, New York, NY Participating Vendors: IBA PTW – New York RTI Electronics, Inc. Standard Imaging, Inc. Sun Nuclear Corporation Small fields are increasing used in specialized radiation treatments such as Gammaknife, Cyberknife, Tomotherapy, IMRT, VMAT, SRS and SBRT. Due to small field size electron transport creates lateral electronic disequilibrium and thus dosimetry could be very difficult. Microdetectors are used for small field dosimetry which will be discussed in preface of this tour as below: Understanding small field e.g. meaning and definition of small field IAEA definition and approach Characteristics of microdetectors in terms of perturbation, recombination, correction Suitability of microdetectors in small field dosimetry.

60 APPLIED LIFE SCIENCES↗

WE-C-TOUR-T-00: Exhibit Hall Guided Tours-Microdosimeters for Therapy (Wednesday) WE-C-TOUR-T-01

Tour Leader: Indra Das, NYU Langone Medical Center, New York, NY Tour Guides: Hsui Ai, Indiana University School of Medicine, Indianapolis, IN Paulina Galvis, NYU Langone Medical Center, New York, NY Olga Volotoskova, NYU Langone Medical Center, New York, NY Participating Vendors: IBA PTW – New York RTI Electronics, Inc. Standard Imaging, Inc. Sun Nuclear Corporation Small fields are increasing used in specialized radiation treatments such as Gammaknife, Cyberknife, Tomotherapy, IMRT, VMAT, SRS and SBRT. Due to small field size electron transport creates lateral electronic disequilibrium and thus dosimetry could be very difficult. Microdetectors are used for small field dosimetry which will be discussed in preface of this tour as below: Understanding small field e.g. meaning and definition of small field IAEA definition and approach Characteristics of microdetectors in terms of perturbation, recombination, correction Suitability of microdetectors in small field dosimetry.

60 APPLIED LIFE SCIENCES↗

Flexible polyvinyl chloride neutron guides for transporting ultracold and very cold neutrons

The transmission of ultracold neutrons (UCNs) through flexible polyvinyl chloride (PVC) tubes with lengths of up to 3 m and an internal diameter of 6-8 mm has been studied. High UCN transmission is found even for arbitrarily bent tubes (single bend, double bend, triple bend, figure eight, etc.). The transmission can be improved significantly by coating the inner surface of the tube with a thin layer of liquid fluorine polymer. The prospects of these neutron guides in fundamental and applied research are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Clean Cities 2012 Vehicle Buyer's Guide (Brochure)

The expanding availability of alternative fuels and advanced vehicles makes it easier than ever to reduce petroleum use, cut emissions, and save on fuel costs. The Clean Cities 2012 Vehicle Buyer's Guide features a comprehensive list of model year 2012 vehicles that can run on ethanol, biodiesel, electricity, propane or natural gas.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗