Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gradient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Fabrication Technologies of the High Gradient Accelerator Structures at 100MV/M Range

A CERN-SLAC-KEK collaboration on high gradient X-band structure research has been established in order to demonstrate the feasibility of the CLIC baseline design for the main linac stably operating at more than 100 MV/m loaded accelerating gradient. Several prototype CLIC structures were successfully fabricated and high power tested. They operated at 105 MV/m with a breakdown rate that meets the CLIC linear collider specifications of < 5 x 10{sup -7}/pulse/m. This paper summarizes the fabrication technologies including the mechanical design, precision machining, chemical cleaning, diffusion bonding as well as vacuum baking and all related assembly technologies. Also, the tolerances control, tuning and RF characterization will be discussed.

43 PARTICLE ACCELERATORS↗

Evidence of Magnetic Breakdown on the Defects With Thermally Suppressed Critical Field in High Gradient SRF Cavities

At SRF 2011 we presented the study of quenches in high gradient SRF cavities with dual mode excitation technique. The data differed from measurements done in 80's that indicated thermal breakdown nature of quenches in SRF cavities. In this contribution we present analysis of the data that indicates that our recent data for high gradient quenches is consistent with the magnetic breakdown on the defects with thermally suppressed critical field. From the parametric fits derived within the model we estimate the critical breakdown fields.

Eremeev, Grigory↗

Growth of large aluminum nitride single crystals with thermal-gradient control

In various embodiments, non-zero thermal gradients are formed within a growth chamber both substantially parallel and substantially perpendicular to the growth direction during formation of semiconductor crystals, where the ratio of the two thermal gradients (parallel to perpendicular) is less than 10, by, e.g., arrangement of thermal shields outside of the growth chamber.

36 MATERIALS SCIENCE↗

Planned High-gradient Flat-beam-driven Dielectric Wakefield Experiments at the Fermilab’s Advanced Superconducting Test Accelerator

In beam driven dielectric wakefield acceleration (DWA), high-gradient short-wavelength accelerating fields are generally achieved by employing dielectric-lined waveguides (DLWs) with small aperture which constraints the beam sizes. In this paper we investigate the possibility of using a low-energy (50-MeV) flat beams to induce high-gradient wakes in a slab-symmetric DLW. We demonstrate via numerical simulations the possibility to produce axial electric field with peak amplitude close to 0.5 GV/m. Our studies are carried out using the Fermilab's Advanced Superconducting Test Accelerator (ASTA) photoinjector beamline. We finally discuss a possible experiment that could be performed in the ASTA photoinjector and eventually at higher energies.

43 PARTICLE ACCELERATORS↗

Growth of large aluminum nitride single crystals with thermal-gradient control

In various embodiments, non-zero thermal gradients are formed within a growth chamber both substantially parallel and substantially perpendicular to the growth direction during formation of semiconductor crystals, where the ratio of the two thermal gradients (parallel to perpendicular) is less than 10, by, e.g., arrangement of thermal shields outside of the growth chamber.

36 MATERIALS SCIENCE↗

High Gradient Accelerating Structures for Carbon Therapy Linac

Carbon therapy is the most promising among techniques for cancer treatment, as it has demonstrated significant improvements in clinical efficiency and reduced toxicity profiles in multiple types of cancer through much better localization of dose to the tumor volume. RadiaBeam, in collaboration with Argonne National Laboratory, are developing an ultra-high gradient linear accelerator, Advanced Compact Carbon Ion Linac (ACCIL), for the delivery of ion-beams with end-energies up to 450 MeV/u for 12C6+ ions and 250 MeV for protons. In this paper, we present a thorough comparison of standing and travelling wave designs for high gradient S-Band accelerating structures operating with ions at varying velocities, relative to the speed of light, in the range 0.3-0.7. In this paper we will compare these types of accelerating structures in terms of RF, beam dynamics and thermo-mechanical performance.

Kutsaev, Sergey↗

System for growth of large aluminum nitride single crystals with thermal-gradient control

In various embodiments, non-zero thermal gradients are formed within a growth chamber both substantially parallel and substantially perpendicular to the growth direction during formation of semiconductor crystals, where the ratio of the two thermal gradients (parallel to perpendicular) is less than 10, by, e.g., arrangement of thermal shields outside of the growth chamber.

36 MATERIALS SCIENCE↗

Optimal Thermal Gradient for Flux Expulsion in 600°C Heat-treated CEBAF 12 GeV Upgrade Cavities

We will present results on measurement of flux expulsion in CEBAF 12 GeV upgrade cavities and original CEBAF cavities and the search for optimal thermal gradient for reducing the trapped flux in cavities installed in CEBAF linacs. Preliminary measurements of one C100 cavities has shown that a nearly perfect flux expulsion can be achieved at an optimal thermal gradient - a surprising result contrary to the expectation of zero flux expulsion for 600°C heat treated niobium cavities. These results could lead to a cost-effective path for improving the quality factor of cavities installed in CEBAF and ultimately saving accelerator operation cost.

Geng, R.↗

History of gradient advances in SRF

Radio frequency (RF) superconductivity has become a key technology for many modern particle accelerators. One of its most salient features of this technology is the ability of superconducting RF cavities to deliver high accelerating gradients in continuous-wave and long-pulse modes of operation. However, reaching the current state of the technology was not an easy fit. Over many years scientists and engineers had to overcome several serous performance limitations. In this paper, I attempt to the best of my knowledge to trace the history of accelerating gradients evolution in the field of superconducting radio frequency. I will restrict the scope to primary innovations along with some of the ensuing developments in developing cavities made of bulk niobium. But I will not cover all the many applications and findings over the subsequent decades of progress that were based on the primary discoveries and inventions. I will also not cover a number of other important topics in the history of cavity developments, such as the drive for higher Q values, or the push for lower cavity costs via Nb/Cu cavities or large grain Nb cavities.

43 PARTICLE ACCELERATORS↗

Basin-wide gradients in dolomite d26Mg and 87Sr/86Sr identify the structural centre of the Williston Basin as a source of magnesium for dolomitization of the Middle Devonian Winnipegosis Formation

Dolomitized carbonates in the Williston Basin are common below the Middle Devonian Prairie Evaporite Formation, indicating a plausible role for brine-reflux as the source of Mg for dolomitization. However, the Lower Member Winnipegosis Formation, which directly underlies the evaporite sequence, exhibits dolomite 87Sr/86Sr ratios that are higher than expected for Middle Devonian seawater, instead suggesting that the dolomitizing fluids ascended from the deep basin where present-day formation waters are known to be more radiogenic. This interpretation is supported in this study by Mg isotope data showing a basin-scale gradient of increasing d26Mg values from the deep center (–2.03‰) to the edge (–1.34‰) of the Williston Basin along the lower Member Winnipegosis bed. Dolomite favors light isotopes of Mg when it forms, thus driving dolomitizing solutions, and the produced dolomite, towards heavier isotopic compositions in the direction of fluid flow. However, dolomite is also Mg-deficient when it forms, and its initial Mg isotope composition is susceptible to alteration by fluid-rock interactions occurring later in the depositional history of the deposit. We argue that the Mg isotope gradient in the Lower Member Winnipegosis was created by an ascending flow of isotopically light Mg-bearing fluid that differentially altered an earlier formed brine-reflux dolomite, with more alteration occurring deeper in the basin and less towards to edges. Alteration of pre-existing dolomite by an Mg isotope exchange mechanism requires large supplies of Mg. This fact, and the direction of fluid flow point to the underlying crystalline basement as an important Mg source for dolomitization in the Williston Basin. We speculate that ultramafic rocks supplied the Mg when they were hydrothermally altered during an anomalous heating event that affected the Williston Basin in the Late Devonian / Early Carboniferous. Seismic pumping drove these fluids upwards through fracture networks in the crust, and eventually into the deep center of the Williston Basin along vertically-oriented down-to-the-basement faults, pressuring deep aquifers like the Winnipegosis, which resulted in fluids migrating up the stratigraphic dip of the beds towards the edges of the basin. Plotting and contouring the dolomite d26Mg data on a map of the Williston Basin reveals the pathways taken by the migrating fluids. One prominent pathway extending outwards from the center of the basin towards the northeast bears a strong resemblance to petroleum migration fairways deduced for the underlying Late Ordovician Red River Formation. This study demonstrates that Mg isotopic mapping of large dolomite bodies is a useful tool for deciphering fluid flow histories in sedimentary basins and may assist in locating migrated petroleum and Mississippi Valley Type ore deposits.

Magnesium Isotopes, Strontium Isotopes, Dolomitiza↗

An Online Dynamic Amplitude-Correcting Gradient Estimation Technique to Align X-ray Focusing Optics

High-brightness X-ray pulses, as generated at synchrotrons and X-ray free electron lasers (XFELs), are used in a variety of scientific experiments. At these facilities, measurements often require optical equipment, e.g Compound Refractive Lenses (CRLs) to be precisely aligned and focused. The lateral alignment of CRLs to a beamline requires precise positioning along four axes: two translational, and the two rotational. At a synchrotron, alignment is often accomplished manually. However, XFEL beamlines present a beam brightness that fluctuates stochastically, making manual alignment a time-consuming endeavor. Automation using simplex or classic stochastic descent often fails, given the errant gradient estimates. Herein we present a dynamic-amplitude correction to the usual gradient based on the combination of a generalized finite difference stencil and a time-dependent sampling pattern. Intensity is recorded periodically, then used to normalize numerical derivatives against fluctuations. Error expectation is analyzed, and efficacy is demonstrated on classic benchmarks. We provide a proof of concept by laterally aligning optics on a simulated XFEL beamline using data recorded at both synchrotron and XFEL facilities.

97 MATHEMATICS AND COMPUTING↗

Numerical simulation of supercritical heat transfer under severe axial density gradient in a narrow vertical tube

A number of computational works have been performed so far for the simulation of heat transfer in a supercritical fluid. The simulations, however, faced a lot of difficulties when heat transfer deteriorates due either to buoyancy or by acceleration. When the bulk temperature approaches the pseudo-critical temperature the fluid experiences a severe axial density gradient on top of a severe radial one. Earlier numerical calculations showed, without exception, unrealistic over-predictions, as soon as the bulk temperature exceeded the pseudo-critical temperature. The over-predictions might have been resulted from an inapplicability of widely-used turbulence models. One of the major causes for the difficulties may probably be an assumption of a constant turbulent Prandtl number. Recent research, both numerical and experimental, indicates that the turbulent Prandtl number is never a constant when the gradient of physical properties is significant. This paper describes the applicability of a variable turbulent Prandtl number to the numerical simulation of heat transfer in supercritical fluids flowing in narrow vertical tubes. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Apparatus and methods for sample analysis with multi-gradient microfluidics

A device for analyzing biological samples comprises first, second, third, and fourth layers. The first layer comprises a sample chamber in which a sample is positioned. The second layer comprises first, second, and third channels. A third, porous layer is positioned between the first layer and the second layer. A fourth layer composed of a substantially liquid-impermeable material is positioned between the second layer and the third layer. The fourth layer includes first and second pass-through channels that are aligned with the first and second channel, respectively. Fluids that flow in the first and second channels pass through the pass-through channels and diffuse into the sample chamber, establishing a chemical concentration gradient therein. A gas in the sample chamber can diffuse through the third and fourth layers and interact with a fluid flowing in the third channel, establishing a gas concentration gradient in the sample chamber.

Kim, Peter Wonhee↗

Study on Electropolishing of N-Doped Niobium Surfaces and 650 MHz Cavity for High-Gradient Performance

This presentation provides an overview of the latest studies on electropolishing (EP) of nitrogen-doped niobium surfaces and 650 MHz cavities. The first study focuses on optimizing EP parameters to achieve a pit-free surface on N-doped niobium, highlighting the effects of process conditions on surface pitting and suggesting strategies for mitigation. The second study investigates the EP of 650 MHz cavities to achieve high-gradient performance comparable to that of 1.3 GHz niobium SRF cavities. Additionally, an example of a 650 MHz single-cell cavity is presented, demonstrating its record-high gradient achieved through optimized EP conditions.

43 PARTICLE ACCELERATORS↗

Non-preconditioned conjugate gradient on cell and FPCA-based hybrid supercomputer nodes

This work presents a detailed implementation of a double precision, Non-Preconditioned, Conjugate Gradient algorithm on a Roadrunner heterogeneous supercomputer node. These nodes utilize the Cell Broadband Engine Architecture{trademark} in conjunction with x86 Opteron{trademark} processors from AMD. We implement a common Conjugate Gradient algorithm, on a variety of systems, to compare and contrast performance. Implementation results are presented for the Roadrunner hybrid supercomputer, SRC Computers, Inc. MAPStation SRC-6 FPGA enhanced hybrid supercomputer, and AMD Opteron only. In all hybrid implementations wall clock time is measured, including all transfer overhead and compute timings.

97 MATHEMATICS AND COMPUTING↗

SLIM, Short-pulse Technology for High Gradient Induction Accelerators

The conclusions of this paper are: (1) The gradient of the SLIM-based technology is believed to be achievable in the same range as it is for the gradient of a modern rf-linac technology ({approx}100 MeV per meter). (2) The SLIM concept is based on the nsec TEM pulse mode operation with no laser or rf systems. (3) Main components of SLIM are not stressed while the energy is pumped into the induction system. Components can accept the hard environment conditions such as a radiation dose, mismatch, hard electromagnetic nose level, etc. Only for several nanoseconds the switch is OFF and produces a stress in the induction system. At that time, the delivery of energy to the beam takes place. (4) The energy in the induction system initially is storied in the magnetic field when the switch is ON. That fact makes another benefit: a low voltage power supplies can be used. The reliability of a lower voltage power supply is higher and they are cheaper. (5) The coreless SLIM concept offers to work in the MHz range of repetition rate. The induction system has the high electric efficiency (much higher than the DWA). (6) The array of lined up and activated SLIM cells is believed to be a solid state structure of novel accelerating technology. The electron-hole plasma in the high power solid state structure is precisely controlled by the electromagnetic process of a pulsed power supply.

43 PARTICLE ACCELERATORS↗

Stability and Surface Topography Evolution in Nanoimprinted Polymer Patterns under a Thermal Gradient

Nanostructures created in polymer films by nanoimprint lithography are subject to large stresses, both those from the imprinting processes as well as stresses arising from the intrinsic thermodynamic instabilities. These stresses can induce nanostructure deformation that can compromise the intended function of the imprinted pattern. Controlling these stresses, and thus the stability of the imprinted patterns, is a key scientific issue for this technology. The requirement of film stability against dewetting requires the use of entangled polymer films, which necessitates an understanding of complex viscoelastic response of these materials to large stresses. Here we investigate the evolution of the surface topography of nanoimprinted patterns in polystyrene films through a high throughput annealing approach in which the patterns are annealed for a fixed time on a controlled temperature gradient. Using principles of time-temperature superposition we systematically explore the effect of varying basic system variables such as pattern feature size, polymer molecular mass, imprinting temperature, on nanopattern stability and on the evolution of imprinted patterns driven by surface tension and internal stress. Nanostructure collapse generally occurs through a combination of a "slumping" instability, where the imprinted film simply relaxes towards a planar film and the film height decreases with time, and a lateral "zigzag" instability in the nanoimprinted lines.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The development of Gibbs's dyadic and implications for the gradient of a vector field

In this paper, we review the history of the dyadic as developed by Gibbs. This mathematical construct appeared in the second part of Gibbs's pamphlet on vector analysis (published in 1884), and it represented the first known development of a Cartesian theory of tensors. Gibbs made extensive use of the dyadic to express his theory of linear vector functions, that is, functions that acted on vectors and mapped them to new vectors. The dyadic proved to be a capable vehicle in Gibbs's hands, and his theory for dyadics (which we would now call second-order Cartesian tensors) was relatively advanced. The theory detailed notions such as the decomposition of vectors and conditions under which a tensor would have an inverse. While Gibbs's theory for linear operators expressed by dyadics was robust, it did not seem to garner the attention that the more conventional vector analysis (published in the first half of his pamphlet in 1881) did. Perhaps in part because of the general unfamiliarity with the dyadic, two distinct and conflicting definitions of the gradient of a vector field have arisen in the literature. The details of these differences in notation, possible reasons for the difference, and a potential resolution are proposed.

97 MATHEMATICS AND COMPUTING↗