Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gamma detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

The UCSD/MIT hard X-ray and low energy gamma ray experiment for HEAO-A

An HEAO-A spacecraft is described which is scheduled for launch in April 1977 to survey the sky in the 0.15 keV to 10 MeV range of X-rays with improved sensitivity and angular resolution. The spectral and time variations of discrete sources, and the spectrum and isotropy of the diffuse component will be measured. A hard X-ray and low energy gamma ray experiment is described which will use as an array of seven (NaI)(Tl)/CsI(Na) phoswich detectors and eight large CsI(Na) shields. Detector events are pulse-height analyzed with a selectable time resolution of 0.1, 0.005, or 0.00002 sec. The instrument background is expected to be comprised of approximately equal parts of diffuse gamma rays entering the aperture, radioactive decay of spallation products, and gamma ray leakage through the shields. Detailed background predictions are presented, and sensitivity estimates indicate that the Crab nebula should be detected up to approximately 5 MeV. Approximate 1% isotropy limits for the diffuse component of cosmic gamma rays should be achieved, and its spectrum measured with improved precision.

Matteson, J. L.↗

The solar flare and cosmic gamma-ray burst experiment aboard the Ulysses spacecraft

The HUS-Ulysses team has prepared an instrument for the Ulysses spacecraft consisting of 2 Csi detectors and 2 Si surface barrier detectors for measuring x rays in the range 5 to 200 keV with up to 8 ms time resolution. The prime objectives of the experiment are the study of solar flares and cosmic gamma-ray bursts. The Ulysses mission will leave the ecliptic during the forthcoming solar maximum. The total time above ecliptic latitudes + or - 70 degrees is expected to be 230 days. The solar data can be used in conjunction with other experiments to measure the directivity of the emission and for correlative studies.

Boer, Michel↗

Defects of perovskite semiconductor CsPbBr3 investigated via photoluminescence and thermally stimulated current spectroscopies

Halide perovskites are essential materials for hard radiation detectors at ambient temperature. To improve detector performance, charge transport must be investigated and optimized. Using photoluminescence (PL) and thermally stimulated current (TSC) spectroscopies, we investigate photogenerated charge carriers in Bridgman-grown CsPbBr3 single crystals to understand the nature of charge transport. PL spectroscopy of these halide perovskites revealed the presence of strong emission bands at the band edge, which were attributed to free or bound excitons. It is shown that a wide broadening of the excitonic linewidth in these halide perovskites arises from strong exciton–phonon coupling, which is substantially dominated by longitudinal optical phonons via Fröhlich interaction. An additional contribution due to the presence of ionized impurities was also observed. Crystals with a detectable sensitivity to high-energy gamma radiation are characterized by a higher intensity and a narrower linewidth of the principal PL peak at 2.326 eV. Defect states beyond 2.214 eV have a negative impact on detector sensitivity to high-energy gamma radiation. TSC spectroscopy reveals an array of trap levels spanning 0.15–0.70 eV, attributed to intrinsic point defects and multiple extrinsic defects involving dopants or impurities. Defects identified included Cs and Br vacancies, as well as Pb interstitials with concentrations in the 1011–1016 cm−3 range. Understanding how the synthesis process impacts the types and concentrations of the defects present is currently under investigation. Elimination or suppression of the defect/trap states should result in halide perovskite materials with longer carrier diffusion lengths and improved detector characteristics.

Physics↗

A bismuth germanate-shielded mercuric iodide X-ray detector for space applications

The development of HgI2 for solid state X-ray detector applications over the past decade was carried out in connection with the ability of the crystal to operate as a detector at room temperature. In order to achieve the lowest background possible for HgI2 detectors in a space-like environment (balloon and/or satellite altitudes), attention was given to the design of a shielding system which actively vetoes nonaperture events such as gamma rays and charged particles that can mimic signal X-rays by partial deposition of energy in the main detector. The detector system consists of two HgI2 detectors mounted back to back and operated in anticoincidence. The two detectors are placed inside a bismuth germanate scintillating shield along with two hybrid charge-sensitive preamps. Monte Carlo simulations of detector performance are discussed.

Vallerga, J. V.↗

UNM High Energy Physics: Task B

The High Altitude Water Cherenkov (HAWC) observatory provides a unique window into the "TeV" gamma-ray universe. HAWC provides an important 1 TeV to 1000 TeV high-mass window for indirect searches for dark matter (DM) annihilation or decay. Additional fundamental physics studies benefit from HAWC's sensitivity to variable and/or transient sources. Such transient sources include: gamma ray bursts (GRBs), temporal studies of super massive black holes (specifically Markarian (Mrk) 421 and 501), and most recently searches for gamma-ray counterparts to PeV neutrino sources (observed by IceCube) and gravitational wave sources (observed by LIGO/Virgo). The UNM (Task B) research program includes leadership of the HAWC detector and of HAWC science. During this final reporting period the UNM group includes Professor John Matthews and graduate student Zhixiang Ren with the research goal focused on the development of analysis tools to enhance the sensitivity of HAWC to <1 TeV, gamma rays. This program began in 2016 with an initial focus to work to resolve known problems with the low energy analysis bins in the HAWC data. In 2017 this evolved to the development of new analysis tools to optimize current HAWC <1 TeV sensitivity as well as how HAWC (or a future HAWC-like detector) could be modified to be significantly more sensitive to <1 TeV gamma rays. In these studies Ren lead the development and evaluation of new HAWC <1 TeV analysis tools and Matthews lead the study of possible experimental modifications to HAWC to improve the <1 TeV sensitivity.

79 ASTRONOMY AND ASTROPHYSICS↗

Gamma Ray Astronomy

The project has progressed successfully during this period of performance. The highlights of the Gamma Ray Astronomy teams efforts are: (1) Support daily BATSE data operations, including receipt, archival and dissemination of data, quick-look science analysis, rapid gamma-ray burst and transient monitoring and response efforts, instrument state-of-health monitoring, and instrument commanding and configuration; (2) On-going scientific analysis, including production and maintenance of gamma-ray burst, pulsed source and occultation source catalogs, gamma-ray burst spectroscopy, studies of the properties of pulsars and black holes, and long-term monitoring of hard x-ray sources; (3) Maintenance and continuous improvement of BATSE instrument response and calibration data bases; (4) Investigation of the use of solid state detectors for eventual application and instrument to perform all sky monitoring of X-Ray and Gamma sources with high sensitivity; and (5) Support of BATSE outreach activities, including seminars, colloquia and World Wide Web pages. The highlights of this efforts can be summarized in the publications and presentation list.

Wu, S. T.↗

A Coincident CdTe Detector Array for Enhanced Nuclear Process Monitoring

Nuclear fuel cycle aqueous separation processes desire improved real-time material characterization and process monitoring techniques; gamma coincidence spectroscopy has the potential to meet this need in these high throughput and high radiation environments based on its ability to reduce background noise, thereby enhancing detection limits and improving isotopic identification accuracy. A detector array composed of three CdTe detectors was designed to surround a chemical processing pipe in a reprocessing facility and evaluate the feasibility of passively assaying the nuclear materials flowing though this measurement point. This array uses commercial off the shelf components that are radiation hard and highly efficiency at low energies relevant to actinide photon signatures. Detector efficiency characterizations, coincidence detection, and potential configuration improvements are presented here.

Good, Erin C.↗

Search for an X-ray identification of a strong gamma-ray source

X-rays from Cygnus X-3 were observed during early 1978 with the detectors of the SAS-3 satellite. These observations in conjunction with earlier UHURU and ANS data indicate that the 4.8 hr period of Cygnus X-3 is increasing at the rate of P/P = (5/1 plus or minus 1.3) x 10 to the minus 6 power/1 yr. The sign and magnitude for this change are incompatible with a rotation model for the period and are in reasonable agreement with model predictions for orbital changes associated with mass loss and transfer in a binary system.

Lamb, R. C.↗

The Crab pulsar light curve in the soft gamma ray range: FIGARO II results

The FIGARO II experiment (a large area, balloon borne, crystal scintillator detector working from 0.15 to 4.3 MeV) observed the Crab pulsar on 1990 Jul. 9 for about seven hours. The study of the pulse profile confirms some structures detected with a low significance during the shorter observation of 1986, and adds new important elements to the picture. In particular, between the two main peaks, two secondary peaks appear centered at phase values 0.1 and 0.3, in the energy range 0.38 to 0.49 MeV; in the same energy range, a spectral feature at 0.44 MeV, interpreted as a redshifted positron annihilation line, was observed during the same balloon flight in the phase interval including the second main peak and the neighboring secondary peak. If the phase interval considered is extended to include also the other secondary peak, the significance of the spectral line appears to increase.

Massaro, E.↗

Isotopic gamma lines for identification of shielding materials

Identifying the constituting materials of concealed objects is crucial in a wide range of sectors, such as medical imaging, geophysics, nonproliferation, national security investigations, and so on. Existing methods face limitations, particularly when multiple materials are involved or when there are challenges posed by scattered radiation and large areal mass. Here we introduce a novel brute-force statistical approach for material identification using high spectral resolution detectors, such as HPGe. The method relies upon updated semianalytic formulae for computing uncollided flux from source of gamma radiation, shielded by a sequence of nested spherical or cylindrical materials. These semianalytical formulae make possible rapid flux estimation for material characterization via combinatorial search through all possible combinations of materials, using a high-resolution HPGe counting detector. An important prerequisite for the method is that the geometry of the objects is known (for example, from X-ray radiography). We demonstrate the viability of this material characterization technique in several use cases with both simulated and experimental data in spherical geometry.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Improved Gamma-Ray Point Source Quantification in Three Dimensions by Modeling Attenuation in the Scene

We discuss using a series of detector measurements taken at different locations to localize a source of radiation as a well-studied problem. The source of radiation is sometimes constrained to a single point-like source, in which case the location of the point source can be found using techniques such as maximum likelihood. Recent advancements have shown the ability to locate point sources in 2D and even 3D, but few have studied the effect of intervening material on the problem. In this work we examine gamma-ray data taken from a freely moving system and develop voxelized 3-D models of the scene using data from the onboard LiDAR. Ray casting is used to compute the distance each gamma ray travels through the scene material, which is then used to calculate attenuation assuming a single attenuation coefficient for solids within the geometry. Parameter estimation using maximum likelihood is performed to simultaneously find the attenuation coefficient, source activity, and source position that best match the data. Using a simulation, we validate the ability of this method to reconstruct the true location and activity of a source, along with the true attenuation coefficient of the structure it is inside, and then we apply the method to measured data with sources and find good agreement.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Heating neutron stars with GeV dark matter

An old neutron star (NS) may capture halo dark matter (DM) and get heated up by the deposited kinetic energy, thus behaving like a thermal DM detector with sensitivity to a wide range of DM masses and a variety of DM-quark interactions. Near future infrared telescopes will measure NS temperatures down to a few thousand Kelvin and probe NS heating by DM capture. We focus on GeV-mass Dirac fermion DM (which is beyond the reach of current DM direct detection experiments) in scenarios in which the DM capture rate can saturate the geometric limit. For concreteness, we study (1) a model that invokes dark decays of the neutron to explain the neutron lifetime anomaly, and (2) a framework of DM coupled to quarks through a vector current portal. In the neutron dark decay model a NS can have a substantial DM population, so that the DM capture rate can reach the geometric limit through DM self-interactions even if the DM-neutron scattering cross section is tiny. We find NS heating to have greater sensitivity than multipion signatures in large underground detectors for the neutron dark decay model, and sub-GeV gamma-ray signatures for the quark vector portal model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thallium-based scintillators for high-resolution gamma-ray spectroscopy: Ce 3+ - doped Tl 2 LaCl 5 and Tl 2 LaBr 5

In this paper we report on the crystallographic and scintillation properties of Tl 2 LaCl 5 :Ce 3 + and Tl 2 LaBr 5 :Ce 3 + , two novel thallium-containing high-resolution scintillators for gamma-ray spectroscopy. Crystals of Tl 2 LaCl 5 :Ce 3 + and Tl 2 LaBr 5 :Ce 3 + were grown by the Vertical Bridgman method up to 1-inch diameter and 1-inch long. Single crystals of Tl 2 LaCl 5 :Ce 3 + and Tl 2 LaBr 5 :Ce 3 + belong to the orthorhombic system with space group 62 and have a density of 5.16 and 5.98 g/cm 3 , respectively. The scintillators show high light yields of up to 68,000 photons/MeV, excellent gamma-ray energy resolution of ≤ 3% at 662 keV, a fast scintillation decay, and a proportional response over a wide range of energies from 32 keV up to 1275 keV. Density Functional Theory calculations show that the Ce 3 + energy levels are inside the bandgap despite the smaller bandgap of Tl 2 LaCl 5 and Tl 2 LaBr 5 compared to K 2 LaCl 5 and K 2 LaBr 5 . Finally, a systematic Ce 3 + concentration study was performed for Tl 2 LaCl 5 :Ce 3 + and trends observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Crystal growth, density functional theory, and scintillation properties of Tl 3 LnCl 6 :Ce 3+ and TlLn 2 Cl 7 :Ce 3+ (Ln = Y, Gd)

In this paper we report on the crystal growth, density functional theory (DFT) calculations and scintillation properties of Tl 3 LnCl 6 :Ce and TlLn 2 Cl 7 :Ce(Ln = Y, Gd). Crystals were grown by the Vertical Bridgman technique up to 16 mm in diameter and 25 mm long. Crystals of Tl 3 YCl 6 :Ce and Tl 3 GdCl 6 :Ce belong to the family of the Nesohalides which have the monoclinic crystal structure. Crystals of TlY 2 Cl 7 :Ce and TlGd 2 Cl 7 :Ce belong to the family of the Phyllohalides which have either the monoclinic or the orthorhombic crystal structure. We report the light yields of these Nesohalides and Phyllohalides are typically on the order of 35,000–40,000 ph/MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel imaging technique for thermal neutrons using a fast optical camera

A novel imaging technique for thermal neutrons using a fast optical camera is presented. Thermal neutrons are reacted with 6 Lithium to produce a pair of 2.73 MeV tritium and 2.05 MeV alpha particles, which in turn interact in a thin layer of LYSO crystal scintillator to produce a localized flash of light. These photons are directed by a pair of lenses to a micro-channel plate intensifier, and its output is connected to the optical camera, TPX3CAM. The results from the camera are reconstructed through a custom algorithm. Various cutting parameters were found through data analysis to eliminate the background, and they were shown effective in matching the simulated rate of the neutron source. The system is fast with 40 ns decay time and allows free-space light collection, both vastly enhances flexibility of neutron detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Growth of High-Purity CsPbBr 3 Crystals for Enhanced Gamma-Ray Detection

High-quality CsPbBr 3 crystals hold significant potential for gamma-ray detection due to their remarkable optoelectronic properties. This study details an optimized production process using the Bridgman method to achieve highly pure CsPbBr 3 crystals. By implementing rigorous synthesis and purification techniques, we successfully reduced the total impurity levels to 9 ppm, as confirmed by glow discharge mass spectroscopy (GDMS). The resulting CsPbBr 3 crystals demonstrate exceptional performance, including high transparency, intense photoemission, and prolonged photoluminescence decay times. These properties facilitate superior gamma-ray detection with an energy resolution of 1.4% for the 137 Cs 662 keV gamma-rays, comparable to commercial Cd 1-x Zn x Te (CZT) detectors. Our findings underscore the critical relationship between material purity and detector performance, highlighting the potential of CsPbBr 3 as a cost-effective alternative in radiation detection applications. Further studies on defect origins and electronic states are necessary to fully leverage the capabilities of CsPbBr 3 crystals in practical high-energy radiation detection systems.

Bridgman↗

National Diagnostic Working Group (NDWG) for inertial confinement fusion (ICF)/high-energy density (HED) science: The whole exceeds the sum of its parts

The National Diagnostic Working Group (NDWG) has led the effort to fully exploit the major inertial confinement fusion/high-energy density facilities in the US with the best available diagnostics. These diagnostics provide key data used to falsify early theories for ignition and suggest new theories, recently leading to an experiment that exceeds the Lawson condition required for ignition. The factors contributing to the success of the NDWG, collaboration and scope evolution, and the methods of accomplishment of the NDWG are discussed in this Review. Examples of collaborations in neutron and gamma spectroscopy, x-ray and neutron imaging, x-ray spectroscopy, and deep-ultraviolet Thomson scattering are given. Here, an abbreviated history of the multi-decade collaborations and the present semiformal management framework is given together with the latest National Diagnostic Plan.

47 OTHER INSTRUMENTATION↗