Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy grid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

VOLTTRON/volttron-pnnl-aems

The Autonomous Energy Management Software (AEMS) system will continuously optimize the operations of the distributed energy resources in the small and medium size commercial building by minimizing energy consumption and cost, while providing a solution for maximizing decarbonization benefits from electrification of buildings. Initially, AEMS system will manage rooftop air conditioners and heat pumps but it can be extended in the future to manage, hot water heaters, storage (battery and thermal), electric vehicle charging and monitoring solar photovoltaic. AEMS support both energy efficiency and grid service features.

Bleeker, Amelia [Pacific Northwest National Labora↗

TEAMER: Supporting model output files for Environmental Compliance Framework for Floating Tidal Turbines, Cook Inlet, AK

Orbital Marine Power (Orbital) is seeking to deploy their floating tidal technology in US waters and has considered the possibility of deploying in temperate waters including the Pacific Northwest (PNW) and the Western Passage, Maine. It has become apparent that some of the most promising tidal sites in the US are located in high latitudes, within the State of Alaska. Within the state, the most likely sites for grid-scale tidal energy are in Cook Inlet, with the largest city (Anchorage) located on the shores, ready and able to absorb the electrical output of a commercial scale tidal development. Through the TEAMER project, Pacific Northwest National Laboratory (PNNL) developed a framework to select environmentally compliant sites partially based on hydrodynamic model output. This uploaded dataset summarizes the key hydrodynamic model output files discussed in the TEAMER project report. Please unzip the file to see actual data files and the ReadMe file. This project is part of the TEAMER RFTS 4 (request for technical support) program.

16 TIDAL AND WAVE POWER↗

Development of Integrated Safety and Security Models for Comprehensive Reliability and Resiliency Evaluation

The security of the electric grid and supporting energy systems is crucial to national security. One of the complexities in analyzing the security of energy systems is the safety consequences that may result from accidents. For energy systems, the goal is to ensure that they operate as intended and that any consequences are mitigated or prevented. The integration of safety and security is paramount to protecting these systems from attacks and ensuring that large consequences are prevented. This report describes an integrated safety and security methodology to evaluate cybersecurity events that can lead to large consequences. This novel approach first describes how Systems-Theoretic Process Analysis (STPA) provides a digital causal analysis for Bayesian Networks (BNs). The use of STPA causal analysis provides a systematic approach to constructing BNs that adequately model cyber scenarios that result in consequences. When combined with the technical principles described in Risk-Informed Management of Enterprise Systems (RIMES), a comprehensive risk-informed cybersecurity analysis results that allows decision-makers to prioritize systems that most impact risk.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantitative risk assessment examples for underground hydrogen storage facilities

Hydrogen energy storage can be used to achieve goals of national energy security, renewable energy integration, and grid resilience. Adapting underground natural gas storage facility (UNGSF) infrastructure for underground hydrogen storage (UHS) is one method of storing large quantities of hydrogen that has already largely been proven to work for natural gas. There are currently some underground salt caverns in the United States that are being used for hydrogen storage by commercial entities, but it is still a fairly new concept in that it has not been widely deployed nor has it been done with other geologic formations like depleted hydrocarbon reservoirs. Assessments of UHS systems can help identify and evaluate risks to people both working within the facility and residing nearby. This report provides example risk assessment methodologies and analyses for generic wellhead and processing facility configurations, specifically in the context of the risks of unintentional hydrogen releases into the air. Assessment of the hydrogen containment in the subsurface is also critically important for a safety assessment for a UHS facility, but those geomechanical assessments are not included in this report.

08 HYDROGEN↗

Environmental Evaluation of Gas Switching Reforming for Low Carbon Hydrogen: A Power-to-X Study

Gas Switching Reforming for hydrogen production (GSR-H2) offers a promising pathway for producing low-carbon hydrogen at scale, with significant implications for Power-to-X (PtX) systems that rely on clean hydrogen as a feedstock for synthetic fuels and chemicals. GSR-H2 integrates inherent carbon capture and thermal self-sufficiency, positioning it as an efficient alternative to conventional steam methane reforming (SMR), proton exchange membrane (PEM) electrolysis, and chemical looping reforming (CLR). Unlike SMR, GSR-H2 avoids external natural gas combustion by leveraging exothermic redox cycles to generate process steam and recover electricity internally. Its innovative reactor design consolidates all reforming stages within a single reactor cluster, eliminating the need for solid circulation found in CLR, thereby reducing capital costs and improving system reliability and scalability. This presentation describes the first environmental life cycle assessment (LCA) of GSR-H2, evaluating its environmental performance across U.S. grid and renewable energy scenarios. In a renewables-powered configuration, GSR-H2 achieves a global warming potential (GWP) of 2.77 kg CO2 equivalent per kg H2, substantially lower than SMR (10.4 kg) and competitive with PEM electrolysis (1.85 kg) and CLR (1.84 kg). Results across additional impact categories, including air quality and water use, support GSR-H2’s role as a complementary hydrogen source in PtX applications. Its reduced environmental burden, thermal integration, and simplified scale-up potential make GSR-H2 a viable contributor to net-zero PtX systems, particularly where renewable energy is abundant and electricity-intensive hydrogen production faces economic or infrastructure constraints.

03 NATURAL GAS↗

Per-Phase and 3-Phase Optimal Coordination of Directional Overcurrent Relays Using Genetic Algorithm

Penetration of the power grid by renewable energy sources, distributed storage, and distributed generators is becoming increasingly common. Increased utilization of these distributed energy resources (DERs) has given rise to additional protection coordination concerns, particularly where they are utilized in an unbalanced manner or where loading among phases is unbalanced. Digital relays such as the SEL-751 (produced by Schweitzer Engineering Laboratories, Pullman, WA, USA) series have the capability of being set on a per-phase basis. This capability is underutilized in common practice. Additionally, in optimization algorithms for determining relay settings, the time-overcurrent characteristics (TOCs) of relays are generally not treated as variables and are assigned before running the optimization algorithm. In this paper, TOC options themselves are treated as discrete variables to be considered in the optimization algorithm. A mixed integer nonlinear programming problem (MINLP) is set up where the goal is to minimize relay operating times. A genetic algorithm (GA) approach is implemented in MATLAB where two cases are considered. In the first case, the TOC and Time dial setting (TDS) of each relay is set on a three-phase basis. In the second case, per-phase settings are considered. Relay TDSs and TOCs are both considered as simultaneous discrete control variables. Despite the stochastic nature of using per-phase settings for unbalanced systems is found to generally allow for shorter operating times. However, for relatively balanced systems, it is best to use three-phase settings if computation time is of importance.

Matthews, Ronald C.↗

Ionosphere-exosphere coupling through charge exchange and momentum transfer in hydrogen-proton collisions

The implications of a traditional assumption of exospheric physics, that collisions of hydrogen atoms and protons preferentially result in charge exchange with negligible momentum transfer are examined. Initially adopted as a necessary convenience to accommodate limited computer resources in exosphere model calculations, this approximation results in a direct transformation of the proton velocity distribution into a hot component of neutral hydrogen. With expanding computational facilities, the need for the approximation has passed. As the first step toward its replacement with a realistic, quantum mechanical model of the H - H(+) collision process, differential and cumulative cross sections were calculated for quantum elastic scattering of indistinguishable nuclei for a fine grid of encounter energies and scattering angles. These data are used to study the nature of ionosphere-exosphere coupling through H - H(+) collisions, and to demonstrate that the distribution of velocities of scattered H produced in the traditional exospheric charge exchange approximation, as well as that arising from an alternative, fluid dynamic approach, leads to unacceptable abundances of coronal atoms in long-term, highly elliptic trajectories.

Hodges, R. R., Jr.↗

Model Validation for Propulsion - On the TFNS and LES Subgrid Models for a Bluff Body Stabilized Flame

This paper summarizes the reacting results of simulating a bluff body stabilized flame experiment of Volvo Validation Rig using a releasable edition of the National Combustion Code (NCC). The turbulence models selected to investigate the configuration are the sub-grid scaled kinetic energy coupled large eddy simulation (K-LES) and the time-filtered Navier-Stokes (TFNS) simulation. The turbulence chemistry interaction used is linear eddy mixing (LEM).

Flame↗

Cyclotron Resonant Scattering Feature Simulations I. Thermally Averaged Cyclotron Scattering Cross Sections, Mean Free Photon-Path Tables, and Electron Momentum Sampling

Electron cyclotron resonant scattering features (CRSFs) are observed as absorption-like lines in the spectra of X-ray pulsars. A significant fraction of the computing time for Monte Carlo simulations of these quantum mechanical features is spent on the calculation of the mean free path for each individual photon before scattering, since it involves a complex numerical integration over the scattering cross section and the (thermal) velocity distribution of the scattering electrons. We aim to numerically calculate interpolation tables which can be used in CRSF simulations to sample the mean free path of the scattering photon and the momentum of the scattering electron. The tables also contain all the information required for sampling the scattering electron's final spin. The tables were calculated using an adaptive Simpson integration scheme. The energy and angle grids were refined until a prescribed accuracy is reached. The tables are used by our simulation code to produce artificial CRSF spectra. The electron momenta sampled during these simulations were analyzed and justified using theoretically determined boundaries. We present a complete set of tables suited for mean free path calculations of Monte Carlo simulations of the cyclotron scattering process for conditions expected in typical X-ray pulsar accretion columns (0.01 B/B(sub crit) is less than or equal to 0.12, where B(sub crit) = 4.413 x 1013 G, and 3 keV kBT 15 keV). The sampling of the tables is chosen such that the results have an estimated relative error of at most 1/15 for all points in the grid. The tables are available online (see link in footnote, page 1).

Schwarm, F.-W.↗

Implementation of a Body Force Model in OVERFLOW for Propulsor Simulations

We present an implementation of a propulsor model based on body force method into the OVERFLOW computational fluid dynamics code to model turbofan engines and propulsors of similar type. The model estimates the forces imparted on the fluid by the blade camber surfaces as a body force source terms in the momentum and energy equations over grids that represent the rotor and stator of a fan stage. We tested the implementation on three cases: 1) Source Diagnostics Test (SDT) fan with R4 rotors, which has extensive test data on aerodynamic performance and rotor wake surveys, 2) A stand-alone Aeronaut TF8000 propulsor which is an off-the-shelf propulsor used on model aircraft and 3) The D8 aircraft model with TF8000 propulsors placed in a wind tunnel. Despite missing some of the features in the velocity profiles near the endwalls (i.e. hub and casing surfaces), the OVERFLOW simulations with body force model predicted area-averaged flow speed and total pressure rise through the SDT propulsor within a few percent of the LDV (Laser Doppler Velocimetry) measurements. In the case of TF8000 propulsor on the D8 airframe, the model under-predicted mechanical power coefficient by several percent of the wind tunnel test results when the horizontal force balance condition over the airframe is targeted by tuning rotor speed. By investigating the upstream influence of the rotor swirl, it was found out that the induced swirl velocity effects upstream were relatively small and they rapidly vanished before reaching one fan diameter upstream of the fan face. The body force model provided insights on aerothermodynamics and aeromechanics of boundary layer ingesting propulsor; these insights could not be obtained by using the uniform pressure jump model.

Propulsor↗

Design of Phase-Change Thermal Storage Device in a Heat Pump for Building Electric Peak Load Shaving: Preprint

Replacing carbon-intensive fossil fuel heating systems with electric heat pumps powered by renewables is a promising approach to decarbonize the building sector. However, one of the technical barriers of this approach is the large scale of heat demand, which will put excessive stress on the electricity grid. Integrating thermal energy storage (TES) into the heating systems can help alleviate this problem, by shifting thermal load and thus shaving peaks in the building electric load. Therefore, it is critical to understand how to design a thermal storage device in a heat pump for peak load shaving. In this study, we developed a numerical model for a cascaded vapor compression heat pump system integrating a phase change thermal storage device. This novel system can control the net thermal charging and discharging rate of the TES independently from the building's thermal load, which allows for precise control of electric power use. In the current study, we controlled the system to shave building electric peak load during a cold winter morning, and to charge TES during the relatively warm afternoon while still providing space heating. We used the model to evaluate the system performance with and without peak shaving. We also investigated the effect of PCM transition Tt on the peak reduction and electric energy saving potentials. The results show that peak shaving scheme effectively reduces the peak electric power consumption during a predefined discharge time window. When comparing to the no shaving case, for PCM Tt = 10 degrees C, the peak electric load reduction is 23.5%. When comparing to an air-source heat pump with back up electric heater, as Tt increases from 0 to 20 degrees C, the peak reduction increases from 46.1% to 50.9%. Integrating PCM Tt = 10 degrees C with peak shaving leads to the 45.5% of electric energy saving, which is the highest among the three transition temperatures.

electric energy saving↗

FLISR in the Presence of DERs ADMS Test Bed Use Case

Fault location, isolation, and restoration (FLISR) is one of the distribution automation applications that utilities are most interested in. It operates groups of switches on distribution feeders to improve the reliability of power delivery after localizing outages. FLISR is an essential function for enabling a self-healing grid, and it directly affects grid reliability and resilience. The presence of DERs brings both new opportunities and challenges for FLISR applications. For instance, some DERs can work as backup generation sources and help energize local networks so more switching options can be achieved with the coordination of FLISR operations; however, the existence of DERs also brings new challenges. The bidirectional power flow resulting from DERs might require dynamic changes to protective devices' fault current settings, and thus the FLISR application will need to dynamically adjust its operations in coordination with the dynamic protection settings. Also, some FLISR applications make their service restoration decisions and close tie-switches based on predefined rules; however, the presence of DERs and their impact on altering net loads on the local feeder network are not considered. For this use case, the project team is using the FLISR application of the Survalent ADMS operating on a real-time simulation of a feeder from Central Georgia EMC, a cooperative electric utility. The performance of the FLISR application is being evaluated for different locations and combinations of DERs, including grid-forming battery energy storage systems.

ADMS↗

Data and Tools for Exploring New Pumped Storage Hydropower Deployment Opportunities

Pumped storage hydropower (PSH) is a flexible energy storage technology with the potential to facilitate variable renewable energy integration into the decarbonized electric grid of the future. NREL is developing new data and tools to help understand opportunities for new PSH deployment, including nationwide resource assessment data, a bottom-up component-level cost model, and a lifecycle greenhouse gas emissions calculator. These datasets lay the foundation for better-informed grid planning decisions about how PSH fits into a future portfolio of generation, transmission, and storage assets.

CEM↗

Study of Communication Boundaries of Primal-Dual Based Distributed Energy Resource Management Systems (DERMS): Preprint

As the coordination of distributed energy resources (DERs) becomes more necessary to provide grid services through a distributed energy resources management system (DERMS), studying the communication requirements for successful real-world low-cost implementation becomes increasingly important. Specifically, this paper studies the needed communication time resolutions between the different system components for a primal-dual based DERMS which is a highly-developed DERMS framework. We design a metric to evaluate the functionality of a DERMS with respect to providing grid services. Using numerical simulations based on a real-world feeder in Colorado, we show that the upper bound on the time resolutions is on the order of minutes instead of the previously assumed order of seconds.

communication time resolution↗

Utilities Find Success Using NREL's ADMS Test Bed for Grid Modernization

The National Renewable Energy Laboratory (NREL) and the U.S. Department of Energy's (DOE's) Office of Electricity have developed a vendor-neutral, advanced distribution management system (ADMS) test bed to accelerate grid modernization efforts for utilities using an ADMS. NREL has partnered with utilities to demonstrate three grid modernization use cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Offshore wind and wave energy can reduce total installed capacity required in zero-emissions grids

Abstract As the world races to decarbonize power systems to mitigate climate change, the body of research analyzing paths to zero emissions electricity grids has substantially grown. Although studies typically include commercially available technologies, few of them consider offshore wind and wave energy as contenders in future zero-emissions grids. Here, we model with high geographic resolution both offshore wind and wave energy as independent technologies with the possibility of collocation in a power system capacity expansion model of the Western Interconnection with zero emissions by 2050. In this work, we identify cost targets for offshore wind and wave energy to become cost effective, calculate a 17% reduction in total installed capacity by 2050 when offshore wind and wave energy are fully deployed, and show how curtailment, generation, and transmission change as offshore wind and wave energy deployment increase.

16 TIDAL AND WAVE POWER↗

The Future of Zero Energy Buildings: Produce, Respond, Regenerate: Preprint

The zero energy buildings concept is more than 20 years old, and the paradigm shift from buildings as energy consumers to buildings as energy producers is underway. Buildings also consume land and material resources, however, with attendant environmental impacts. Another paradigm is emerging: a built environment that produces energy and is environmentally responsive and regenerative. This paper investigates an updated framework for thinking about zero energy buildings that includes discussions of prioritizing renewables; determining on-site versus off-site generation; exploring how and when buildings should use energy; and balancing renewables, storage, and energy efficiency. Buildings are typically connected to the utility grid and the utility grid develops largely in response to the built environment. If more buildings’ real time electricity use aligned with renewable generation, more renewables would be added to the grid. Ultimately, the goal for zero energy buildings will be to use 100% renewables, 100% of the time, matching loads with energy storage and renewable generation at each discrete timestep over a year. This target is beyond the current zero energy definitions, which focus on an annual balance of renewable supply and energy demand and use the grid to “store” excess production to make up for hours without sufficient on-site renewable generation. This paper expands this upgraded concept and outlines simple metrics to evaluate the alignment of renewable sources and storage with building loads. This process can provide insights on building design considerations, including the use of flexible loads and optimal resource management.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Time Sequence Machine Learning-Based Data Intrusion Detection for Smart Voltage Source Converter-Enabled Power Grid

Smart inverters of distributed energy resources can enable cloud computing, condition monitoring, result visualization, remote control, and peer-to-peer energy trading in advanced power systems. However, the advent of data injection attacks in the communication architecture can alter measurement characteristics of power grids and have devastating consequences. In this article, we propose a time sequence machine learning-based anomaly detection methodology for detecting cyber intrusion into control signal setpoints and dc voltage signal measurement bias of the voltage source converter (VSC) in wind generators. We first investigated the effects of four types of denial of service, tampering signal, and stealthy-type data intrusion attacks on smart VSCs and overall wind farms. We then proposed a novel time sequence machine learning-based intrusion detection framework that can be implemented to detect different cyberattacks in the VSCs. The performance of the proposed framework has been compared with that of autoencoder and clustering-based intrusion detection framework. The proposed framework was validated by using the IEEE 39 bus power system in the presence of four wind farms in different locations. Using several metrics for intrusion detection performance, we validated the effectiveness of the proposed framework.

42 ENGINEERING↗