Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Bayesian Fit to NOvA Data Subsamples for Three Flavor Oscillation Analysis

NOvA (NuMI Off-Axis $\nu_e$ Appearance) is a long baseline neutrino experiment designed to measure the oscillation of muon neutrinos to electron neutrinos over a distance of 810 km. NOvA uses a near and far detector to observe $\nu_\mu$ disappearance and $\nu_e$ appearance of neutrinos produced by the NuMI beam at Fermilab. NOvA uses a Bayesian analysis framework in addition to its Frequentist method to measure neutrino oscillation parameters such as the mixing angles, mass ordering, and CP-violating phase. We report preliminary results of Bayesian fits to representative NOvA datasets. Comparison of fits to $\nu_\mu$ disappearance and $\nu_e$ appearance enables a cross-check of NOvA results with reactor $\bar{\nu_e}$ disappearance measurements. NOvA also searches for violation of Lorentz invariance by analyzing fits of forward horn current (FHC) versus reverse horn current (RHC) samples. The results validate and advance NOvA's contributions to precision measurements of neutrino properties.

Zhao, Larry [Fermilab]↗

4-Dimensional Trackers

4-dimensional (4D) trackers with ultra fast timing (10-30 ps) and very fine spatial resolution (O(few $\mu$m)) represent a new avenue in the development of silicon trackers, enabling new physics capabilities beyond the reach of the existing tracking detectors. This paper reviews the impact of integrating 4D tracking capabilities on several physics benchmarks both in potential upgrades of the HL-LHC experiments and in several detectors at future colliders, and summarizes the currently available sensor technologies as well as electronics, along with their limitations and directions for R$\&$D.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutrino Hunting: Looking through a UV Lens Scintillation Photon Detection in a Large-Volume Liquid Argon Time Projection Chamber, Exposed to a Multi-GeV Charged Particle Beam

The Deep Underground Neutrino Experiment (DUNE) will be a world-class neutrino observatory and nucleon decay detector designed to answer fundamental questions about elementary particles and their role in the universe. The DUNE experiment will consist of a a Near Detector, located at Fermilab, and a Far Detector, approximately 1.5~km underground at the Sanford Underground Research Facility in South Dakota, located $\sim$1300~km away. The accelerator complex at Fermilab will host an intense beam of neutrinos directed toward the two detectors. My dissertation centers on the implementation of technologies used to detect scintillation photon signals in liquid argon in the context of the DUNE's Far Detector Single-Phase (SP) module design, and features direct contributions to the Photon Detection System (PDS) deployed in the ProtoDUNE-SP Large-Volume Liquid Argon Time Projection Chamber (LArTPC) prototype. The PDS is needed for non-beam event timing, such as atmospheric neutrinos, proton d ecay, and supernova detection. The PDS provides a prompt signal ($t_{0}$ information) for micro-second event time determination, which improves the TPC's spatial localization along drift direction, enables accurate ionization-signal-attenuation determination, and even provides calorimetry. My dissertation will discuss an overview of the DUNE and ProtoDUNE-SP experiment and how we detect neutrinos in LAr, via charge and scintillation light. It will discuss my core experimental and analysis work, in regards to the Photon Detection System; including my contributions in establishing procedures for the commissioning and integration for the Photon Detector System that will be valuable during the construction, installation, commissioning, and operations of the DUNE Far Detector. In addition, it will comprehensively discuss the capability of three different photon detection technologies, and their characteristics and responses to muon and electron beam particles over a range of beam momenta , from 0.3~GeV/$c$ - 7~GeV/$c$. Further, the overall progress detailed in this thesis will help pave the way toward understanding the physical properties of these detectors, which will contribute to the success of the sensitivity measurements required for determining the neutrino mass hierarchy and $\delta_{CP}$.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-energy calibration of a PILATUS3 CdTe detector for hard x-ray measurements of magnetically confined fusion plasmas

A multi-energy hard x-ray pin-hole camera based on the PILATUS3 X 100K-M CdTe detector has been developed at the Princeton Plasma Physics Laboratory for installation on the Tungsten Environment in Steady State Tokamak. This camera will be employed to study thermal plasma features such as electron temperature as well as non-thermal effects such as fast electron tails produced by a lower hybrid radiofrequency current drive and the birth of runaway electrons. The innovative aspect of the system lies in the possibility of setting the threshold energy independently for each of the ~100k pixels of the detector. This feature allows for the measurement of the x-ray emission in multiple energy ranges with adequate space and time resolution (~1 cm, 2 ms) and coarse energy resolution. In this work, the energy dependence of each pixel was calibrated within the range 15 keV–100 keV using a tungsten x-ray tube and emission from a variety of fluorescence targets (from yttrium to uranium). The data corresponding to pairs of K α emission lines are fit to the characteristic responsivity (“S-curve”), which describes the detector sensitivity across the 64 possible energy threshold values for each pixel; this novel capability is explored by fine-tuning the voltage of a six-bit digital-analog converter after the charge-sensitive amplifier for each of the ~100k pixels. Here, this work presents the results of the calibration including a statistical analysis. It was found that the achievable energy resolution is mainly limited by the width of the S-curve to 3 keV–10 keV for threshold energies up to 50 keV, and to ≥20 keV for energies above 60 keV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Machine learning assisted unfolding for neutrino cross-section measurements with the OmniFold technique

The choice of unfolding method for a cross-section measurement is tightly coupled to the model dependence of the efficiency correction and the overall impact of cross-section modeling uncertainties in the analysis. A key issue is the dimensionality used in unfolding, as the kinematics of all outgoing particles in an event typically affect the reconstruction performance in a neutrino detector. OmniFold is an unfolding method that iteratively reweights a simulated dataset, using machine learning to utilize arbitrarily high-dimensional information, that has previously been applied to proton-proton and proton-electron datasets. This paper demonstrates OmniFold’s application to a neutrino cross-section measurement for the first time using a public T2K near detector simulated dataset, comparing its performance with traditional approaches using a mock data study.

Machine learning↗

Evaluation of a streaming readout solution for Jefferson Lab experiments

Jefferson Lab (JLab) operates the CEBAF accelerator that provides a high energy (up to 12 GeV) and high current (up to 150 µA) polarized electron beam for fixed target experiments. JLab's mission is to provide substantial progress in understanding the Quantum Chromo Dynamics (QCD), the current theory of the spectrum and the dynamics of hadronic matter. Given the broad scientific program a general-purpose detector, CLAS12, has been designed and constructed. Such a detector requires a sophisticated trigger and current experiments use an on-line FPGA-based system that relies upon custom firmware and electronics both of which are difficult reconfigure from one experiment to the next. To overcome these challenges transitioning to a streaming readout has been proposed since it would allow a more flexible, easier to debug, software trigger to be developed. To facilitate this JLab is gaining experience with streaming readout systems and is actively working to design and test a streaming data acquisition architecture. Significant work has already been done to make existing front-end electronics compatible with operation in streaming mode. Software-wise, much work remains to be done but an existing framework, TriDAS, which was developed for underwater neutrino telescopes can, in principle, be used with the existing JLab hardware. A test stand is already in place in the INDRA DAQ development lab at JLab. This paper will present the development of this TriDAS based test system and it?s operation in-beam using parts of the CLAS12 detector to evaluate streaming readout for a large general purpose detector.

Battaglieri, Marco↗

Search for Light Pseudoscalar Bosons, Pair-Produced in Higgs Boson Decays in the Four-Electron Final State in Proton-Proton Collisions at $\sqrt{s}=13$ TeV

A search for pairs of light neutral pseudoscalar bosons (𝐴) resulting from the decay of a Higgs boson is performed. The search is conducted using LHC proton-proton collision data at $\sqrt{s}=13$ TeV, collected with the CMS detector in 2016–2018 and corresponding to an integrated luminosity of 138 fb −1 . The 𝐴 boson decays into a highly collimated electron-positron pair. A novel multivariate algorithm using tracks and calorimeter information is developed to identify these distinctive signatures, and events are selected with two such merged electron-positron pairs. No significant excess above the standard model background predictions is observed. Upper limits on the branching fraction for 𝐻 → 𝐴⁢𝐴 → 4⁢𝑒 are set at 95% confidence level, for masses between 10 and 100 MeV and proper decay lengths below 100 μ⁢m, reaching branching fraction sensitivities as low as 10 −5 . This is the first search for Higgs boson decays to four electrons via light pseudoscalars at the LHC. It significantly improves the experimental sensitivity to axionlike particles with masses below 100 MeV.

Hayrapetyan, A. [Yerevan Physics Institute]↗

Development of High-QE GaN Photodectors for Liquid Noble Particle Detectors

Detection of the handful of photons generated when a dark matter particle interacts in a liquid Xenon detector requires a new type of photodetector with very high detection efficiency at ultraviolet wavelengths, very low radioactive backgrounds, and essentially no measureable readout noise (achieved with devices with high intrisic gain). Such devices would find wide applicability to not only high energy physics experiments, but to a number of commercial applications including, e.g., biomedical imaging of fluorescent tags. We developed photodetectors based on amorphous GaN thin film structures (photocathodes) grown by molecular beam epitaxy on quartz windows. We also developed approaches to integrate these photocathode device structures with vacuum electron multipliers. All materials and fabrication techniques were developed to minimize radioactive backgrounds in materials, so these detectors could be used for very low count rate experiments, such as the future liquid-Xenon dark matter detectors, and future liquid-Argon neutrino detectors. We demonstrated growth of very high quantum efficiency amorphous GaN cathodes grown on a number of different substrates (Stainless steel, p-Silicon) reaching detection efficiencies of 80% at 220nm. The key to this growth was to use nitrogen plasma-assistend MBEs and very low growth temperatures. We also discovered that thinner structures (e.g.,40nm a-GaN thin films) had the best performance. We successfully demonstrated techniques for the vacuum transfer of these photocathode structures to a novel chamber that used hydraulics and bellow to form a cold indium bond needed to integrate these cathodes into sealed-tube devices. A complete, stand-along, device could not be completed during this proposal period due to difficulties in growing structures on the thick quartz window. Subsequent work is aimed at addressing this difficulty, by growing a buffer layer on the quartz substrate.

07 ISOTOPE AND RADIATION SOURCES↗

Optimizing energetic light dark matter searches in dark matter and neutrino experiments

Neutrino and dark matter experiments with large-volume ($ \underset{\sim }{>} $,2 1 ton) detectors can provide excellent sensitivity to signals induced by energetic light dark matter coming from the present universe. Taking boosted dark matter as a concrete example of energetic light dark matter, we scrutinize two representative search channels, electron scattering and proton scattering including deep inelastic scattering processes, in the context of elastic and inelastic boosted dark matter, in a completely detector-independent manner. In this work, a dark gauge boson is adopted as the particle to mediate the interactions between the Standard Model particles and boosted dark matter. We find that the signal sensitivity of the two channels highly depends on the (mass-)parameter region to probe, so search strategies and channels should be designed sensibly especially at the earlier stage of experiments. In particular, the contribution from the boosted-dark-matter-initiated deep inelastic scattering can be subleading (important) compared to the quasi-elastic proton scattering, if the mass of the mediator is below (above) $ \mathcal{O} $(GeV). We demonstrate how to practically perform searches and relevant analyses, employing example detectors such as DarkSide-20k, DUNE, Hyper-Kamiokande, and DeepCore, with their respective detector specifications taken into consideration. For other potential detectors we provide a summary table, collecting relevant information, from which similar studies can be fulfilled readily.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Large active-area superconducting microwire detector array with single-photon sensitivity in the near-infrared

Superconducting nanowire single photon detectors (SNSPDs) are the highest-performing technology for time-resolved single-photon counting from the UV to the near-infrared. The recent discovery of single-photon sensitivity in micrometer-scale superconducting wires is a promising pathway to explore for large active area devices with application to dark matter searches and fundamental physics experiments. We present 8-pixel $1 mm^2$ superconducting microwire single photon detectors (SMSPDs) with $1\,\mathrm{\mu m}$-wide wires fabricated from WSi and MoSi films of various stoichiometries using electron-beam and optical lithography. Devices made from all materials and fabrication techniques show saturated internal detection efficiency at 1064 nm in at least one pixel, and the best performing device made from silicon-rich WSi shows single-photon sensitivity in all 8 pixels and saturated internal detection efficiency in 6/8 pixels. This detector is the largest reported active-area SMSPD or SNSPD with near-IR sensitivity published to date, and the first report of an SMSPD array. By further optimizing the photolithography techniques presented in this work, a viable pathway exists to realize larger devices with $cm^2$-scale active area and beyond.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the sodium and iodine scintillation quenching factors across multiple NaI(Tl) detectors to identify systematics

The amount of light produced by nuclear recoils in scintillating targets is strongly quenched compared to that produced by electrons. A precise understanding of the quenching factor is particularly interesting for weakly interacting massive particles (WIMP) searches and coherent elastic neutrino-nucleus scattering ( CE ν NS ) measurements since both rely on nuclear recoils, whereas energy calibrations are more readily accessible from electron recoils. There is a wide variation among the current measurements of the quenching factor in sodium iodide (NaI) crystals, especially below 10 keV, the energy region of interest for dark matter and CE ν NS studies. A better understanding of the quenching factor in NaI(Tl) is of particular interest for resolving the decades-old puzzle in the field of dark matter between the null results of most WIMP searches and the claim for dark matter detection by the DAMA/LIBRA collaboration. In this work, we measured sodium and iodine quenching factors for five small NaI(Tl) crystals grown with similar thallium concentrations and growth procedures. Unlike previous experiments, multiple crystals were tested, with measurements made in the same experimental setup to control systematic effects. The quenching factors agree in all crystals we investigated, and both sodium and iodine quenching factors are smaller than those reported by DAMA/LIBRA. The dominant systematic effect was due to the electron equivalent energy calibration originating from the nonproportional behavior of the NaI(Tl) light yield at lower energies, potentially the cause for the discrepancies among the previous measurements. Published by the American Physical Society 2024

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cryogenic light detectors with thermal signal amplification for 0 νββ search experiments

As a step towards the realization of cryogenic-detector experiments to search for neutrinoless double-beta decay (such as CROSS, BINGO, and CUPID), we investigated a batch of 10 Ge light detectors (LDs) assisted by Neganov-Trofimov-Luke (NTL) signal amplification. Each LD was assembled with a large cubic light-emitting crystal (45 mm side) using the recently developed CROSS mechanical structure. The detector array was operated at milli-Kelvin temperatures in a pulse-tube cryostat at the Canfranc underground laboratory in Spain. We achieved good performance with scintillating bolometers from CROSS, made of Li 2 100 MoO 4 crystals and used as reference detectors of the setup, and with all LDs tested (except for a single device that encountered an electronics issue). No leakage current was observed for 8 LDs with an electrode bias up to 100 V. Operating the LDs at an 80 V electrode bias applied in parallel, we obtained a gain of around 9 in the signal-to-noise ratio of these devices, allowing us to achieve a baseline noise RMS of O(10 eV). Thanks to the strong current polarization of the temperature sensors, the time response of the devices was reduced to around half a millisecond in rise time. The achieved performance of the LDs was extrapolated via simulations of pile-up rejection capability for several configurations of the CUPID detector structure. Despite the sub-optimal noise conditions of the LDs (particularly at high frequencies), we demonstrated that the NTL technology provides a viable solution for background reduction in CUPID.

47 OTHER INSTRUMENTATION↗

Measurements and interpretations of W ± Z production cross-sections in pp collisions at $\sqrt{s}=13$ TeV with the ATLAS detector

Measurements of integrated and differential cross-sections for W ± Z production in proton-proton collisions are presented. The data collected by the ATLAS detector at the Large Hadron Collider from 2015 to 2018 at a centre-of-mass energy of $\sqrt{s}=13$ TeV are used, corresponding to an integrated luminosity of 140 fb −1 . The W ± Z candidate events are reconstructed using leptonic decay modes of the gauge bosons into electrons or muons. The integrated cross-section per lepton flavour for the production of W ± Z is measured in the detector fiducial region with a relative precision of 4%. The measured value is compared with the Standard Model prediction at a precision of up to next-to-next-to-leading-order in QCD and next-to-leading-order in electroweak. Cross-sections for W + Z and W − Z production and their ratio are presented. The W ± Z production is also measured differentially as functions of various kinematic variables, including new observables sensitive to CP-violation effects. All measurements are compared with state-of-the-art Standard Model predictions from fixed-order calculations or Monte Carlo generators based on next-to-leading-order matrix elements interfaced with parton showers. An effective field theory interpretation of the measurements is performed, considering both CP-conserving and CP-violating dimension-6 operators modifying the W ± Z production. In the absence of observed deviations from the Standard Model, limits on CP-conserving Wilson coefficients are extracted using the transverse mass of the W ± Z system. For CP-violating coefficients a machine learning approach is used to construct an observable with enhanced sensitivity to CP-violation effects.

hadron-hadron scattering↗

Low-threshold response of a scintillating xenon bubble chamber to nuclear and electronic recoils

A device filled with pure xenon first demonstrated the ability to operate simultaneously as a bubble chamber and scintillation detector in 2017. Initial results from data taken at thermodynamic thresholds down to ∼4 keV showed sensitivity to ∼20 keV nuclear recoils with no observable bubble nucleation by 𝛾-ray interactions. Here, this paper presents results from further operation of the same device at thermodynamic thresholds as low as 0.50 keV, hardware limited. The bubble chamber has now been shown to have sensitivity to ∼1 keV nuclear recoils while remaining insensitive to bubble nucleation by 𝛾-rays. A data-driven calibration of the chamber’s nuclear recoil nucleation response, as a function of nuclear recoil energy and thermodynamic state, is presented. Stringent upper limits are established for the probability of bubble nucleation by 𝛾-ray-induced Auger cascades, with a limit of <1.1 ×10 −6 set at 0.50 keV, the lowest thermodynamic threshold explored.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Influence of carrier trapping on radiation detection properties in $\mathrm{CVD}$ grown 4H-SiC epitaxial layers with varying thickness up to 250 µm

We report low doped n-type 4H-SiC epitaxial layers of thickness 50, 150, and 250 µm grown by hot wall chemical vapor deposition were used to fabricate Ni/4H-SiC Schottky radiation detectors. The epitaxial layers were grown on the (0001) face of highly conductive bulk 4H-SiC substrates 8° offcut towards the $\langle 11\bar{2}1\rangle$ direction. The 50, 150, and 250 µm thick epilayer detectors, under optimized settings, showed energy resolutions of 2.0%, 0.78%, and 0.63%, respectively for 5.48 MeV alpha particles. Deep level transient spectroscopy studies showed that the observed variation in the detector resolution is linked to the defect parameters in the devices. Least-squares fitting of the bias dependence of the charge collection efficiency according to a drift-diffusion model, revealed minority carrier diffusion lengths of 16, 10, and 9.2 µm, respectively, implying that the detectors are not limited by minority carrier trapping. The detector performance was observed to be primarily dependent on the concentration and capture cross-sections of the lifetime killing electron traps Z 1/2 and EH 6/7 .

36 MATERIALS SCIENCE↗