Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “damping control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Adaptive Flight Control Design with Optimal Control Modification on an F-18 Aircraft Model

In the presence of large uncertainties, a control system needs to be able to adapt rapidly to regain performance. Fast adaptation is referred to as the implementation of adaptive control with a large adaptive gain to reduce the tracking error rapidly; however, a large adaptive gain can lead to high-frequency oscillations which can adversely affect the robustness of an adaptive control law. A new adaptive control modification is presented that can achieve robust adaptation with a large adaptive gain without incurring high-frequency oscillations as with the standard model-reference adaptive control. The modification is based on the minimization of the Y2 norm of the tracking error, which is formulated as an optimal control problem. The optimality condition is used to derive the modification using the gradient method. The optimal control modification results in a stable adaptation and allows a large adaptive gain to be used for better tracking while providing sufficient robustness. A damping term (v) is added in the modification to increase damping as needed. Simulations were conducted on a damaged F-18 aircraft (McDonnell Douglas, now The Boeing Company, Chicago, Illinois) with both the standard baseline dynamic inversion controller and the adaptive optimal control modification technique. The results demonstrate the effectiveness of the proposed modification in tracking a reference model.

Burken, John J.↗

Entanglement and quantum teleportation via decohered tripartite entangled states

The entanglement behavior of two classes of multi-qubit system, GHZ and GHZ like states passing through a generalized amplitude damping channel is discussed. Despite this channel causes degradation of the entangled properties and consequently their abilities to perform quantum teleportation, one can always improve the lower values of the entanglement and the fidelity of the teleported state by controlling on Bell measurements, analyzer angle and channel’s strength. Using GHZ-like state within a generalized amplitude damping channel is much better than using the normal GHZ-state, where the decay rate of entanglement and the fidelity of the teleported states are smaller than those depicted for GHZ state.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Accuracy of derivatives of control performance using a reduced structural model

The sensitivity of control system performance to structural changes is calculated for a multi-span beam with direct-rate feedback vibration control. Reduced models based on the natural modes of the structure are formed and derivatives of the damping ratios of the closed-loop eigenvalues are calculated. The convergence of the derivatives of the damping ratios with increasing number of modes is shown to be slower than the convergence of the damping ratios themselves. In particular, in some cases the convergence of finite-element approximations to the derivatives is much faster than the convergence of the modal approximations. The results indicate that the use of reduced models based on natural vibration modes may be ill-advised for calculating the sensitivity of control system performance to changes in the controlled structure.

Sandridge, Chris A.↗

Dynamic profile of a prototype pivoted proof-mass actuator

A prototype of a linear inertial reaction actuation (damper) device employing a flexure-pivoted reaction (proof) mass is discussed. The mass is driven by an electromechanic motor using a dc electromagnetic field and an ac electromagnetic drive. During the damping process, the actuator dissipates structural kinetic energy as heat through electromagnetic damping. A model of the inertial, stiffness and damping properties is presented along with the characteristic differential equations describing the coupled response of the actuator and structure. The equations, employing the dynamic coefficients, are oriented in the form of a feedback control network in which distributed sensors are used to dictate actuator response leading to a specified amount of structural excitation or damping.

Miller, D. W.↗

Sampled-Data Techniques Applied to a Digital Controller for an Altitude Autopilot

Sampled-data theory, using the Z transformation, is applied to the design of a digital controller for an aircraft-altitude autopilot. Particular attention is focused on the sensitivity of the design to parameter variations and the abruptness of the response, that is, the normal acceleration required to carry out a transient maneuver. Consideration of these two characteristics of the system has shown that the finite settling time design method produces an unacceptable system, primarily because of the high sensitivity of the response to parameter variations, although abruptness can be controlled by increasing the sampling period. Also demonstrated is the importance of having well-damped poles or zeros if cancellation is attempted in the design methods. A different method of smoothing the response and obtaining a design which is not excessively sensitive is proposed, and examples are carried through to demonstrate the validity of the procedure. This method is based on design concepts of continuous systems, and it is shown that if no pole-zero cancellations are allowed in the design, one can obtain a response which is not too abrupt, is relatively insensitive to parameter variations, and is not sensitive to practical limits on control-surface rate. This particular design also has the simplest possible pulse transfer function for the digital controller. Simulation techniques and root loci are used for the verification of the design philosophy.

Schmidt, Stanley F.↗

Short wavelength limits of current shot noise suppression

Shot noise in electron beam was assumed to be one of the features beyond control of accelerator physics. Current results attained in experiments at Accelerator Test Facility in Brookhaven and Linac Coherent Light Source in Stanford suggest that the control of the shot noise in electron beam (and therefore of spontaneous radiation and Self Amplified Spontaneous Emission of Free Electron Lasers) is feasible at least in the visible range of the spectrum. Here, we present a general linear formulation for collective micro-dynamics of e-beam noise and its control. Specifically, we compare two schemes for current noise suppression: a quarter plasma wavelength drift section and a combined drift/dispersive (transverse magnetic field) section. We examine and compare their limits of applicability at short wavelengths via considerations of electron phase-spread and the related Landau damping effect.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On Controllability of Structures with Closely Spaced Natural Frequencies Based on Perturbation Analysis

His paper investigated the influence of frequency intensity parameters on the controllability of structures with closely-spaced natural frequencies. The perturbation equations were established for a closed-loop system to study the relationship between frequencies, mode damping ratios and perturbation parameters. The calculation results showed that the damping ratios of two modes are decreasing as the decreasing of intensity parameter values of the structure with closely spaced natural frequencies, indicating that the controllability of corresponding modes was losing. The uncertainties in mass and stiffness matrices were also discussed in this paper.

97 MATHEMATICS AND COMPUTING↗

Quantifying climate feedbacks in polar regions

The concept of feedback is key in assessing whether a perturbation to a system is amplified or damped by mechanisms internal to the system. In polar regions, climate dynamics are controlled by both radiative and non-radiative interactions between the atmosphere, ocean, sea ice, ice sheets and land surfaces. Precisely quantifying polar feedbacks is required for a process-oriented evaluation of climate models, a clear understanding of the processes responsible for polar climate changes, and a reduction in uncertainty associated with model projections. This quantification can be performed using a simple and consistent approach that is valid for a wide range of feedbacks, thus offering the opportunity for more systematic feedback analyses and a better understanding of polar climate changes.

54 ENVIRONMENTAL SCIENCES↗

IGM damping wing constraints on the tail end of reionization from the enlarged XQR-30 sample

ABSTRACT The attenuation of Lyα photons by neutral hydrogen in the intergalactic medium (IGM) at z ≳ 5 continues to be a powerful probe for studying the epoch of reionization. Given a framework to estimate the intrinsic (true) Lyα emission of high-z sources, one can infer the ionization state of the IGM during reionization. In this work, we use the enlarged XQR-30 sample of 42 high-resolution and high signal-to-noise quasar spectra between $5.8\lesssim \, z\lesssim \, 6.6$ obtained with VLT/X-shooter to place constraints on the IGM neutral fraction. This is achieved using our existing Bayesian QSO reconstruction framework which accounts for uncertainties such as the: (i) posterior distribution of predicted intrinsic Lyα emission profiles (obtained via covariance matrix reconstruction of the Lyα and N v emission lines from unattenuated high-ionization emission line profiles; C iv, Si iv + O iv], and C iii]) and (ii) distribution of ionized regions within the IGM using synthetic damping wing profiles drawn from a 1.63 Gpc3 reionization simulation. Following careful quality control, we used 23 of the 42 available QSOs to obtain constraints/limits on the IGM neutral fraction during the tail-end of reionization. Our median and 68th percentile constraints on the IGM neutral fraction are: $0.20\substack{+0.14 -0.12}$ and $0.29\substack{+0.14 -0.13}$ at z = 6.15 and 6.35. Further, we also report 68th percentile upper limits of $\bar{x}_{\mathrm{H\, {\small I}}{}} \lt 0.21$, 0.20, 0.21, and 0.18 at z = 5.8, 5.95, 6.05, and 6.55. These results imply reionization is still ongoing at $5.8\lesssim \, z\lesssim \, 6.55$, consistent with previous results from XQR-30 (dark fraction and Lyα forest) along with other observational probes considered in the literature.

Greig, B. (ORCID:0000000240852094)↗

Benefits and Costs of Improved IEQ in U.S. Offices

This paper estimates some of the benefits and costs of implementing scenarios that improve indoor environmental quality (IEQ) in the stock of U.S. office buildings. The scenarios include increasing ventilation rates when they are below 10 or 15 L/s per person, adding outdoor-air economizers and controls when absent, eliminating winter indoor temperatures greater than 23 oC, and reducing dampness and mold problems. The estimated benefits of the scenarios analyzed are substantial in magnitude, including increased work performance, reduced sick building syndrome symptoms, reduced absence, and improved thermal comfort for millions of office workers. The combined potential annual economic benefit of a set ofnon-overlapping scenarios is approximately $20 billion. While the quantitative estimates have a high uncertainty, the opportunity for substantial benefits is clear. Some IEQ improvement measures will save energy while improving health or productivity, and implementing these measures should be the highest priority.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Universal Battery Supercharger

During the course of the UBS project a dc-fast charger was developed to be used in off board high power charging stations. High efficiency is targeted to reduce the charging price for the consumer while reducing the charge time. In the meantime, the size of the converter is minimized so that it could be used in small spaces and potentially urban areas. The topology is modular, and the power level can be expanded for charging higher power vehicles like trucks and buses. During the course of this research several key technologies was developed in LESES that improve the performance of the power electronics system used in EV charger. Integrated magnetics was developed for DMCR to improve the power density as well as efficiency of the magnetic components which is one of the main bottlenecks of EV development. Triangular mode EV current conduction mode is using to perform soft switching (increase efficiency) without adding any new components to the existing topology. Passive and active damping are developed to suppress the interaction between grid and converter, stabilizing the control system. Further numerous other technical problems have been solved to pave the way for even higher performance converters in the future.

25 ENERGY STORAGE↗

An active nutation damper for spacecraft

An active nutation damping device, consisting of an angular accelerometer, a dc motor driven flywheel, and associated electronics, was developed for spacecraft use. This damping system was used on the Lageos spacecraft, launched 4 May 1976, to control nutation buildup during the long coast period after the third stage separation. Of many electrical and mechanical design choices, an angular rather than linear accelerometer offered some advantages but problems developed in adapting the angular accelerometer to spacecraft use. The damper package was evaluated and proven on a three axis gas-bearing simulator that duplicated the Lageos spacecraft critical flight dynamics. A failure analysis of the damper assembly was performed. Performance of the damper during the Lageos flight has confirmed the preflight evaluation and analysis.

Abercrombie, R. A.↗

An active nutation damper for spacecraft

An active nutation damping device, consisting of an angular accelerometer, a dc-motor-driven flywheel, and associated electronics, was developed for spacecraft use. This damping system was used on the LAGEOS spacecraft, launched May 4, 1976, to control nutation buildup during the long coast period (approximately 75 minutes) after the third stage separation. Of the many electrical and mechanical design choices involved, the use of an angular rather than linear accelerometer offers some advantages. There are some problems of adapting the angular accelerometer to spacecraft use. The damper package was evaluated and proven on a three-axis gas-bearing simulator that duplicated the LAGEOS spacecraft critical flight dynamics. A failure analysis of the damper assembly was performed.

Abercrombie, R. A.↗

Design of adaptive control systems by means of self-adjusting transversal filters

The design of closed-loop adaptive control systems based on nonparametric identification was addressed. Implementation is by self-adjusting Least Mean Square (LMS) transversal filters. The design concept is Model Reference Adaptive Control (MRAC). Major issues are to preserve the linearity of the error equations of each LMS filter, and to prevent estimation bias that is due to process or measurement noise, thus providing necessary conditions for the convergence and stability of the control system. The controlled element is assumed to be asymptotically stable and minimum phase. Because of the nonparametric Finite Impulse Response (FIR) estimates provided by the LMS filters, a-priori information on the plant model is needed only in broad terms. Following a survey of control system configurations and filter design considerations, system implementation is shown here in Single Input Single Output (SISO) format which is readily extendable to multivariable forms. In extensive computer simulation studies the controlled element is represented by a second-order system with widely varying damping, natural frequency, and relative degree.

Merhav, S. J.↗

Active Suppression of Rotor Vibrations

In active rotor control, vibrations of flexibly supported rotors suppressed by use of electronic feedback control system. System senses vibration level of rotor system and, in turn, provides damping such that vibration level maintained within acceptable limits. Enables rotor to operate through and above its critical speeds, increases bearing life, reduces size and weight of rotating shafts, and generally enables rotors to operate more smoothly.

Dirusso, Eliseo↗

Investigation of difficult component effects on finite element model vibration prediction for the Bell AH-1G helicopter. Volume 1: Ground vibration test results

Under the NASA-sponsored Design Analysis Methods for VIBrationS (DAMVIBS) program, a series of ground vibration tests and NASTRAN finite element model (FEM) correlations were conducted on the Bell AH-1G helicopter gunship to investigate the effects of difficult components on the vibration response of the airframe. Previous correlations of the AH-1G showed good agreement between NASTRAN and tests through 15 to 20 Hz, but poor agreement in the higher frequency range of 20 to 30 Hz. Thus, this effort emphasized the higher frequency airframe vibration response correlations and identified areas that need further R and T work. To conduct the investigations, selected difficult components (main rotor pylon, secondary structure, nonstructural doors/panels, landing gear, engine, fuel, etc.) were systematically removed to quantify their effects on overall vibratory response of the airframe. The entire effort was planned and documented, and the results reviewed by NASA and industry experts in order to ensure scientific control of the testing, analysis, and correlation exercise. In particular, secondary structure and damping had significant effects on the frequency response of the airframe above 15 Hz. Also, the nonlinear effects of thrust stiffening and elastomer mounts were significant on the low frequency pylon modes below main rotor 1p (5.4 Hz). The results of the ground vibration testing are presented.

Dompka, R. V.↗

Investigation of difficult component effects on finite element model vibration prediction for the Bell AG-1G helicopter. Volume 2: Correlation results

Under the NASA-sponsored DAMVIBS (Design Analysis Methods for VIBrationS) program, a series of ground vibration tests and NASTRAN finite element model (FEM) correlations were conducted on the Bell AH-1G helicopter gunship to investigate the effects of difficult components on the vibration response of the airframe. Previous correlations of the AG-1G showed good agreement between NASTRAN and tests through 15 to 20 Hz, but poor agreement in the higher frequency range of 20 to 30 Hz. Thus, this effort emphasized the higher frequency airframe vibration response correlations and identified areas that need further R and T work. To conduct the investigations, selected difficult components (main rotor pylon, secondary structure, nonstructural doors/panels, landing gear, engine, furl, etc.) were systematically removed to quantify their effects on overall vibratory response of the airframe. The entire effort was planned and documented, and the results reviewed by NASA and industry experts in order to ensure scientific control of the testing, analysis, and correlation exercise. In particular, secondary structure and damping had significant effects on the frequency response of the airframe above 15 Hz. Also, the nonlinear effects of thrust stiffening and elastomer mounts were significant on the low frequency pylon modes below main rotor 1p (5.4 Hz). The results of the NASTRAN FEM correlations are given.

Dompka, R. V.↗

Bridge feedback for active damping augmentation

A method is described for broadband damping augmentation of a structural system in which the active members (with feedback control) were developed such that their mechanical input impedance can be electrically adjusted to maximize the energy dissipation rate in the structural system. The active member consists of sensors, an actuator, and a control scheme. A mechanical/electrical analogy is described to model the passive structures and the active members in terms of their impedance representation. As a result, the problem of maximizing dissipative power is analogous to the problem of impedance matching in the electrical network. Closed-loop performance was demonstrated for single- and multiple-active-member controlled truss structure.

Chen, G.-S.↗