Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “control volume methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Theory and Applications of Macroscale Models in Porous Media

Systems dominated by heterogeneity over a multiplicity of scales, like porous media, still challenge our modeling efforts. The presence of disparate length- and time-scales that control dynamical processes in porous media hinders not only models predictive capabilities, but also their computational efficiency. Macrosopic models, i.e., averaged representations of pore-scale processes, are computationally efficient alternatives to microscale models in the study of transport phenomena in porous media at the system, field or device scale (i.e., at a scale much larger than a characteristic pore size). We present an overview of common upscaling methods used to formally derive macroscale equations from pore-scale (mass, momentum and energy) conservation laws. This review includes the volume averaging method, mixture theory, thermodynamically constrained averaging, homogenization, and renormalization group techniques. We apply these methods to a number of specific problems ranging from food processing to human bronchial system, and from diffusion to multiphase flow, to demonstrate the methods generality and flexibility in handling different applications. The primary intent of such an overview is not to provide a thorough review of all currently available upscaling techniques, nor a complete mathematical treatment of the ones presented, but rather a primer on some of the tools available for upscaling, the basic principles they are based upon, and their specific advantages and drawbacks, so to guide the reader in the choice of the most appropriate method for particular applications and of the most relevant technical literature.

42 ENGINEERING↗

Sliceable, Moldable, and Highly Conductive Electrolytes for All-Solid-State Batteries

All-solid-state batteries (ASSBs) require solid electrolytes with high ionic conductivity, stability, and deformability for optimal energy and power density. Here, we developed lithium-deficient lithium yttrium bromide (LYB) solid electrolytes, Li 3–x YBr 6–x (0 ≤ x ≤ 0.50), using a comelting method with controlled lithium deficiency. These electrolytes exhibit favorable mechanical properties such as high moldability and sliceability. The Li 2.65 YBr 5.65 composition has an ionic conductivity of 4.49 mS cm –1 at 25 °C and an activation energy of 0.28 eV. Compared to Li 3 YBr 6 , Li 2.65 YBr 5.65 demonstrates improved rate performance and cycling stability in ASSBs. High-resolution X-ray diffraction confirms the formation of the LYB phase with a C2/m space group. Structural analysis reveals increased cation disorder and larger polyhedral volumes for x > 0 in Li 3–x YBr 6–x , contributing to reduced Li + migration energy barriers. Bond valence site energy calculations and molecular dynamics simulations reveal enhanced 3D lithium-ion transport. NMR spectroscopy further highlights increased Li + dynamics and impurity elimination.

Poudel, Tej P. [Florida State Univ., Tallahassee, ↗

Large-scale synthesis of Ba{sub x}Sr{sub 1−x}TiO{sub 3} nanowires with controlled stoichiometry

This study demonstrates a highly efficient method for large-scale synthesis BaTiO{sub 3} nanowires (NWs) using a two-step hydrothermal reaction. This synthesis process provides a facile approach to the growth of BaTiO{sub 3} NWs with high yield and control over the stoichiometry of the Ba{sub x}Sr{sub 1−x}TiO{sub 3} solid solution. The ferroelectricity of the BaTiO{sub 3} NWs is directly characterized using atomic force microscopy with the piezoelectric strain coupling coefficient (d{sub 33}) reaching 31.1 pm/V. This work provide an avenue for high volume manufacturing of ferroelectric NWs, allowing both fundamental investigation of nanoscale ferroelectricity as well as their future application in the electrical devices.

36 MATERIALS SCIENCE↗

Innovative Approach for Developing Spacecraft Interior Acoustic Requirement Allocation

The Orion Multi-Purpose Crew Vehicle (MPCV) is an American spacecraft for carrying four astronauts during deep space missions. This paper describes an innovative application of Power Injection Method (PIM) for allocating Orion cabin continuous noise Sound Pressure Level (SPL) limits to the sound power level (PWL) limits of major noise sources in the Environmental Control and Life Support System (ECLSS) during all mission phases. PIM is simulated using both Statistical Energy Analysis (SEA) and Hybrid Statistical Energy Analysis-Finite Element (SEA-FE) models of the Orion MPCV to obtain the transfer matrix from the PWL of the noise sources to the acoustic energies of the receivers, i.e., the cavities associated with the cabin habitable volume. The goal of the allocation strategy is to control the total energy of cabin habitable volume for maintaining the required SPL limits. Simulations are used to demonstrate that applying the allocated PWLs to the noise sources in the models indeed reproduces the SPL limits in the habitable volume. The effects of Noise Control Treatment (NCT) on allocated noise source PWLs are investigated. The measurement of source PWLs of involved fan and pump development units are also discussed as it is related to some case-specific details of the allocation strategy discussed here.

Chu, S. Reynold↗

Innovative Approach for Developing Spacecraft Interior Acoustic Requirement Allocation

The Orion Multi-Purpose Crew Vehicle (MPCV) is an American spacecraft for carrying four astronauts during deep space missions. This paper describes an innovative application of Power Injection Method (PIM) for allocating Orion cabin continuous noise Sound Pressure Level (SPL) limits to the sound power level (PWL) limits of major noise sources in the Environmental Control and Life Support System (ECLSS) during all mission phases. PIM is simulated using both Statistical Energy Analysis (SEA) and Hybrid Statistical Energy Analysis-Finite Element (SEA-FE) models of the Orion MPCV to obtain the transfer matrix from the PWL of the noise sources to the acoustic energies of the receivers, i.e., the cavities associated with the cabin habitable volume. The goal of the allocation strategy is to control the total energy of cabin habitable volume for maintaining the required SPL limits. Simulations are used to demonstrate that applying the allocated PWLs to the noise sources in the models indeed reproduces the SPL limits in the habitable volume. The effects of Noise Control Treatment (NCT) on allocated noise source PWLs are investigated. The measurement of source PWLs of involved fan and pump development units are also discussed as it is related to some case-specific details of the allocation strategy discussed here.

Chu, S. Reynold↗

Hanford Tank Waste Treatment and Immobilization Plant (WTP) Waste Feed Qualification Program Development Approach - 13114

The Hanford Tank Waste Treatment and Immobilization Plant (WTP) is a nuclear waste treatment facility being designed and constructed for the U.S. Department of Energy by Bechtel National, Inc. and subcontractor URS Corporation (under contract DE-AC27-01RV14136 [1]) to process and vitrify radioactive waste that is currently stored in underground tanks at the Hanford Site. A wide range of planning is in progress to prepare for safe start-up, commissioning, and operation. The waste feed qualification program is being developed to protect the WTP design, safety basis, and technical basis by assuring acceptance requirements can be met before the transfer of waste. The WTP Project has partnered with Savannah River National Laboratory to develop the waste feed qualification program. The results of waste feed qualification activities will be implemented using a batch processing methodology, and will establish an acceptable range of operator controllable parameters needed to treat the staged waste. Waste feed qualification program development is being implemented in three separate phases. Phase 1 required identification of analytical methods and gaps. This activity has been completed, and provides the foundation for a technically defensible approach for waste feed qualification. Phase 2 of the program development is in progress. The activities in this phase include the closure of analytical methodology gaps identified during Phase 1, design and fabrication of laboratory-scale test apparatus, and determination of the waste feed qualification sample volume. Phase 3 will demonstrate waste feed qualification testing in support of Cold Commissioning. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TU-CD-304-01: FEATURED PRESENTATION and BEST IN PHYSICS (THERAPY): Trajectory Modulated Arc Therapy: Development of Novel Arc Delivery Techniques Integrating Dynamic Table Motion for Extended Volume Treatments

Purpose: Integration of coordinated robotic table motion with inversely-planned arc delivery has the potential to resolve table-top delivery limitations of large-field treatments such as Total Body Irradiation (TBI), Total Lymphoid Irradiation (TLI), and Cranial-Spinal Irradiation (CSI). We formulate the foundation for Trajectory Modulated Arc Therapy (TMAT), and using Varian Developer Mode capabilities, experimentally investigate its practical implementation for such techniques. Methods: A MATLAB algorithm was developed for inverse planning optimization of the table motion, MLC positions, and gantry motion under extended-SSD geometry. To maximize the effective field size, delivery trajectories for TMAT TBI were formed with the table rotated at 270° IEC and dropped vertically to 152.5cm SSD. Preliminary testing of algorithm parameters was done through retrospective planning analysis. Robotic delivery was programmed using custom XML scripting on the TrueBeam Developer Mode platform. Final dose was calculated using the Eclipse AAA algorithm. Initial verification of delivery accuracy was measured using OSLDs on a solid water phantom of varying thickness. Results: A comparison of DVH curves demonstrated that dynamic couch motion irradiation was sufficiently approximated by static control points spaced in intervals of less than 2cm. Optimized MLC motion decreased the average lung dose to 68.5% of the prescription dose. The programmed irradiation integrating coordinated table motion was deliverable on a TrueBeam STx linac in 6.7 min. With the couch translating under an open 10cmx20cm field angled at 10°, OSLD measurements along the midline of a solid water phantom at depths of 3, 5, and 9cm were within 3% of the TPS AAA algorithm with an average deviation of 1.2%. Conclusion: A treatment planning and delivery system for Trajectory Modulated Arc Therapy of extended volumes has been established and experimentally demonstrated for TBI. Extension to other treatment techniques such as TLI and CSI is readily achievable through the developed platform. Grant Funding by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Method for multi-axis, non-contact mixing of magnetic particle suspensions

Continuous, three-dimensional control of the vorticity vector is possible by progressively transitioning the field symmetry by applying or removing a dc bias along one of the principal axes of mutually orthogonal alternating fields. By exploiting this transition, the vorticity vector can be oriented in a wide range of directions that comprise all three spatial dimensions. Detuning one or more field components to create phase modulation causes the vorticity vector to trace out complex orbits of a wide variety, creating very robust multiaxial stirring. This multiaxial, non-contact stirring is particularly attractive for applications where the fluid volume has complex boundaries, or is congested.

42 ENGINEERING↗

Design of the Universal Neutron Irradiator

SHINE medical isotopes is developing a novel method to produce the medical isotope Mo-99, which is the parent of Tc-99m, the most widely used diagnostic compound in nuclear medicine. This method utilizes U-235 fission in a subcritical liquid target solution, driven by an accelerator-based neutron source that is based on a deuterium-tritium reaction in a gaseous target. In this approach, the neutron-generating target is surrounded by uranyl sulfate (low-enriched uranium); fission in the uranium salt solution efficiently produces the desired Mo-99, as well as other fission products. After irradiation, Mo-99 is separated and the uranyl sulfate solution can be irradiated again to produce Mo-99. This allows the solution to be recycled for a very long time and significantly reduces the amount of associated nuclear waste. SHINE has received U.S. Nuclear Regulatory Commission (NRC) approval to construct an Mo-99 production facility based on this method. In order to produce Mo-99 efficiently, the solution should be as close as possible to criticality. Because the solution is over moderated, any precipitation could push the solution to become critical and thereby hard to control. One of the possible precipitation scenarios is the formation of uranyl peroxide. Under irradiation, water decomposes into the products of radiolysis, some of which will form peroxide. To prevent precipitation, one has to develop a way to decompose the peroxide before it can react with uranium and form hard-to-dissolve precipitates. To study peroxide formation and develop methods to prevent precipitation, we are developing an experiment capable of mimicking radiation conditions in the SHINE system. This report describes the irradiation setup we designed to irradiate a small volume of uranyl sulfate solution for the duration of one SHINE irradiation (~6 days) at the relevant fission power (~0.5 W/cc)

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Dual-Use Space Technology Transfer Conference and Exhibition

This is the second volume of papers presented at the Dual-Use Space Technology Transfer Conference and Exhibition held at the Johnson Space Center February 1-3, 1994. Possible technology transfers covered during the conference were in the areas of information access; innovative microwave and optical applications; materials and structures; marketing and barriers; intelligent systems; human factors and habitation; communications and data systems; business process and technology transfer; software engineering; biotechnology and advanced bioinstrumentation; communications signal processing and analysis; medical care; applications derived from control center data systems; human performance evaluation; technology transfer methods; mathematics, modeling, and simulation; propulsion; software analysis and decision tools; systems/processes in human support technology; networks, control centers, and distributed systems; power; rapid development; perception and vision technologies; integrated vehicle health management; automation technologies; advanced avionics; and robotics technologies.

Krishen, Kumar↗

Lewis Structures Technology, 1988. Volume 3: Structural Integrity Fatigue and Fracture Wind Turbines HOST

The charter of the Structures Division is to perform and disseminate results of research conducted in support of aerospace engine structures. These results have a wide range of applicability to practioners of structural engineering mechanics beyond the aerospace arena. The specific purpose of the symposium was to familiarize the engineering structures community with the depth and range of research performed by the division and its academic and industrial partners. Sessions covered vibration control, fracture mechanics, ceramic component reliability, parallel computing, nondestructive evaluation, constitutive models and experimental capabilities, dynamic systems, fatigue and damage, wind turbines, hot section technology (HOST), aeroelasticity, structural mechanics codes, computational methods for dynamics, structural optimization, and applications of structural dynamics, and structural mechanics computer codes.

Source record↗

Microscale depletion of high abundance proteins in human biofluids using IgY14 immunoaffinity resin: Analysis of human plasma and cerebrospinal fluid

Removal of highly abundant proteins in plasma is often carried out using immunoaffinity depletion to extend the dynamic range of measurements to lower abundance species. While commercial depletion columns are available for this purpose, they generally are not applicable to limited sample quantities (<20 µL) due to low yields stemming from losses caused by nonspecific binding to the column matrix. Additionally, the cost of the depletion media can be prohibitive for larger scale studies. Modern LC-MS instrumentation provides the sensitivity necessary to scale-down depletion methods with minimal sacrifice to proteome coverage, which makes smaller volume depletion columns desirable for maximizing sample recovery when samples are limited, as well as for reducing the expense of large scale studies. We characterized the performance of a 346 µL column volume micro-scale depletion system, using four different flow rates to determine the most effective depletion conditions for ~6 μL injections of human plasma proteins and then evaluated depletion reproducibility at the optimum flow rate condition. Depletion of plasma using a commercial 10 mL depletion column served as the control. Results showed depletion efficiency of the micro-scale column increased as flow rate decreased, and that our micro-depletion was reproducible. We found, in an initial application, a 600 µL sample of human cerebral spinal fluid (CSF) pooled from multiple sclerosis patients was depleted and then analyzed using reversed phase liquid chromatography-mass spectrometry to demonstrate the utility of the system for this important biofluid where sample quantities are more commonly limited.

59 BASIC BIOLOGICAL SCIENCES↗

Prospective Study of Epidermal Growth Factor Receptor Tyrosine Kinase Inhibitors Concurrent With Individualized Radiotherapy for Patients With Locally Advanced or Metastatic Non-Small-Cell Lung Cancer

Purpose: To establish the safety profile and efficacy of epidermal growth factor receptor tyrosine kinase inhibitors (EGFR-TKIs) concurrent with individualized radiotherapy (RT) in patients with locally advanced or metastatic non-small-cell lung cancer (NSCLC). Patients and Methods: Between June 2007 and January 2010, 26 patients with Stage III/IV NSCLC were enrolled in this prospective study. These patients were treated with EGFR-TKIs (gefitinib 250 mg or erlotinib 150 mg, oral daily) concurrent with individualized RT with curative intent. The thoracic RT plans were individually designed on the basis of tumor size and normal tissue volume constraints. All patients were assessed for toxicity, and 25 patients were available for efficacy. The primary endpoints were acute toxicity, overall survival, and median survival time. The secondary endpoints included local control rate, time to tumor progression, and progression-free survival (PFS). Results: Median gross tumor volume, mean lung dose, and lung V20 were 56 cm{sup 3}, 8.6 Gy, and 14%, respectively. Median thoracic radiation dose was 70 Gy at a margin of gross tumor volume (range, 42-82 Gy), and median biological equivalent dose was 105 Gy (range, 60-119 Gy). Acute skin, hematologic, esophageal, and pulmonary toxicities were acceptable and manageable. Severe adverse events included neutropenia (Grade 4, 4%) and thrombocytopenia (Grade 4, 8%), esophagitis (Grade 3, 4%), and pneumonitis (Grade 3, 4%). With a median follow-up of 10.2 months, a local control rate of 96% was achieved for thoracic tumor. Median time to progression, median PFS, and median survival time were 6.3, 10.2, and 21.8 months, respectively. The 1- and 2-year PFS rates were both 42%, and 1-, 2-, and 3-year overall survival rates were 57%, 45%, and 30%, respectively. Conclusion: Concurrent EGFR-TKIs with individualized RT shows a favorable safety profile and promising outcome, therefore serving as a therapeutic option for patients with locally advanced or metastatic NSCLC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Curative Treatment of Stage I Non-Small-Cell Lung Cancer in Patients With Severe COPD: Stereotactic Radiotherapy Outcomes and Systematic Review

Objectives: Patients with severe chronic obstructive pulmonary disease (COPD) have a high risk of lung cancer and of postsurgical complications. We studied outcomes after stereotactic body radiotherapy (SBRT) in patients with severe COPD, as defined by Global Initiative for Chronic Obstructive Lung Disease (GOLD) criteria, and performed a systematic review of the literature on outcomes after SBRT or surgery in these patients. Methods: A single-institution cohort of 176 patients with COPD GOLD III-IV and Stage I non-small-cell lung cancer (NSCLC) treated with SBRT was evaluated. A systematic review identified studies reporting outcomes after SBRT or surgery for Stage I NSCLC in patients with GOLD III-IV or a predicted postoperative forced expiratory volume in 1 second (FEV1) of {<=}40%. Results: In the single-institution cohort, median follow-up was 21 months and median overall survival (OS) was 32 months. Actuarial 3-year local control was 89%, and 1- and 3-year OS were 79% and 47%, respectively. COPD severity correlated with OS (p = 0.01). The systematic review identified four other studies (two surgical, two SBRT, n = 196 patients). SBRT studies were published more recently and included older patients than surgical studies. Mean 30-day mortality was 0% post-SBRT and 10% after surgery. Local or locoregional control was high ({>=}89%) after both treatments. Post-SBRT, actuarial OS was 79-95% at 1 year and 43-70% at 3 years. Postsurgical actuarial OS was 45-86% at 1 year and 31-66% at 3 years. Conclusions: SBRT and surgery differ in risk of 30-day mortality in patients with severe COPD. Despite the negative selection of SBRT patients, survival at 1 and 3 years is comparable between the two treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hematopoietic Stem and Progenitor Cell Migration After Hypofractionated Radiation Therapy in a Murine Model

Purpose: To characterize the recruitment of bone marrow (BM)-derived hematopoietic stem and progenitor cells (HSPCs) within tumor microenvironment after radiation therapy (RT) in a murine, heterotopic tumor model. Methods and Materials: Lewis lung carcinoma tumors were established in C57BL/6 mice and irradiated with 30 Gy given as 2 fractions over 2 days. Tumors were imaged with positron emission tomography/computed tomography (PET/CT) and measured daily with digital calipers. The HSPC and myelomonocytic cell content was assessed via immunofluorescent staining and flow cytometry. Functionality of tumor-associated HSPCs was verified in vitro using colony-forming cell assays and in vivo by rescuing lethally irradiated C57BL/6 recipients. Results: Irradiation significantly reduced tumor volumes and tumor regrowth rates compared with nonirradiated controls. The number of CD133{sup +} HSPCs present in irradiated tumors was higher than in nonirradiated tumors during all stages of regrowth. CD11b{sup +} counts were similar. PET/CT imaging and growth rate analysis based on standardized uptake value indicated that HSPC recruitment directly correlated to the extent of regrowth and intratumor cell activity after irradiation. The BM-derived tumor-associated HSPCs successfully formed hematopoietic colonies and engrafted irradiated mice. Finally, targeted treatment with a small animal radiation research platform demonstrated localized HSPC recruitment to defined tumor subsites exposed to radiation. Conclusions: Hypofractionated irradiation resulted in a pronounced and targeted recruitment of BM-derived HSPCs, possibly as a mechanism to promote tumor regrowth. These data indicate for the first time that radiation therapy regulates HSPC content within regrowing tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Body Radiation Therapy Boost After Concurrent Chemoradiation for Locally Advanced Non-Small Cell Lung Cancer: A Phase 1 Dose Escalation Study

Purpose: Stereotactic body radiation therapy (SBRT) boost to primary and nodal disease after chemoradiation has potential to improve outcomes for advanced non-small cell lung cancer (NSCLC). A dose escalation study was initiated to evaluate the maximum tolerated dose (MTD). Methods and Materials: Eligible patients received chemoradiation to a dose of 50.4 Gy in 28 fractions and had primary and nodal volumes appropriate for SBRT boost (<120 cc and <60 cc, respectively). SBRT was delivered in 2 fractions after chemoradiation. Dose was escalated from 16 to 28 Gy in 2 Gy/fraction increments, resulting in 4 dose cohorts. MTD was defined when ≥2 of 6 patients per cohort experienced any treatment-related grade 3 to 5 toxicity within 4 weeks of treatment or the maximum dose was reached. Late toxicity, disease control, and survival were also evaluated. Results: Twelve patients (3 per dose level) underwent treatment. All treatment plans met predetermined dose-volume constraints. The mean age was 64 years. Most patients had stage III disease (92%) and were medically inoperable (92%). The maximum dose level was reached with no grade 3 to 5 acute toxicities. At a median follow-up time of 16 months, 1-year local-regional control (LRC) was 78%. LRC was 50% at <24 Gy and 100% at ≥24 Gy (P=.02). Overall survival at 1 year was 67%. Late toxicity (grade 3-5) was seen in only 1 patient who experienced fatal bronchopulmonary hemorrhage (grade 5). There were no predetermined dose constraints for the proximal bronchial-vascular tree (PBV) in this study. This patient's 4-cc PBV dose was substantially higher than that received by other patients in all 4 cohorts and was associated with the toxicity observed: 20.3 Gy (P<.05) and 73.5 Gy (P=.07) for SBRT boost and total treatment, respectively. Conclusions: SBRT boost to both primary and nodal disease after chemoradiation is feasible and well tolerated. Local control rates are encouraging, especially at doses ≥24 Gy in 2 fractions. Toxicity at the PBV is a concern but potentially can be avoided with strict dose-volume constraints.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An inorganic capping strategy for the seeded growth of versatile bimetallic nanostructures

Metal nanostructures have attracted great attention in various fields due to their tunable properties through precisely tailored sizes, compositions and structures. Using mesoporous silica (mSiO 2 ) as the inorganic capping agent and encapsulated Pt nanoparticles as the seeds, we developed a robust seeded growth method to prepare uniform bimetallic nanoparticles encapsulated in mesoporous silica shells (PtM@mSiO 2 , M = Pd, Rh, Ni and Cu). Unexpectedly, we found that the inorganic silica shell is able to accommodate an eight-fold volume increase in the metallic core by reducing its thickness. The bimetallic nanoparticles encapsulated in mesoporous silica shells showed enhanced catalytic properties and thermal stabilities compared with those prepared with organic capping agents. As a result, this inorganic capping strategy could find a broad application in the synthesis of versatile bimetallic nanostructures with exceptional structural control and enhanced catalytic properties.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

SU-E-J-232: Feasibility of MRI-Based Preplan On Low Dose Rate Prostate Brachytherapy

Purpose: To investigate the feasibility of using MRI-based preplan for low dose rate prostate brachytherapy. Methods: 12 patients who received transrectal ultrasound (TRUS) guided prostate brachytherapy with Pd-103 were retrospectively studied. Our care-standard of the TRUS-based preplan served as the control. One or more prostate T2-weighted wide and/or narrow-field of view MRIs obtained within the 3 months prior to the implant were imported into the MIM Symphony software v6.3 (MIM Software Inc., Cleveland, OH) for each patient. In total, 37 MRI preplans (10 different image sequences with average thickness of 4.8mm) were generated. The contoured prostate volume and the seed counts required to achieve adequate dosimetric coverage from TRUS and MRI preplans were compared for each patient. The effects of different MRI sequences and image thicknesses were also investigated statistically using Student’s t-test. Lastly, the nomogram from the MRI preplan and TRUS preplan from our historical treatment data were compared. Results: The average prostate volume contoured on the TRUS and MRI were 26.6cc (range: 12.6∼41.3cc), and 27.4 cc (range: 14.3∼50.0cc), respectively. Axial MRI thicknesses (range: 3.5∼8.1mm) did not significantly affect the contoured volume or the number of seeds required on the preplan (R2 = 0.0002 and 0.0012, respectively). Four of the MRI sequences (AX-T2, AX-T2-Whole-Pelvis, AX-T2-FSE, and AXIALT2- Hi-Res) showed statistically significant better prostate volume agreement with TRUS than the other seven sequences (P <0.01). Nomogram overlay between the MRI and TRUS preplans showed good agreement; indicating volumes contoured on MRI preplan scan reliably predict how many seeds are needed for implant. Conclusion: Although MRI does not allow for determination of the actual implant geometry, it can give reliable volumes for seed ordering purposes. Our future work will investigate if MRI is sufficient to reliably replace TRUS preplanning in patients where preplan TRUS may be technically challenging.

60 APPLIED LIFE SCIENCES↗