Neural Network-Based Electric Vehicle Range Prediction for Smart Charging Optimization

Range prediction is a standard feature in most modern road vehicles, allowing drivers to make informed decisions about when to refuel. Most vehicles make range predictions through data- or model-driven means, monitoring the average fuel consumption rate or using a tuned vehicle model to predict fuel consumption. The uncertainty of future driving conditions makes the range prediction problem challenging, particularly for less pervasive battery electric vehicles (BEV). Most contemporary machine learning-based methods attempt to forecast the battery SOC discharge profile to predict vehicle range. In this work, we propose a novel approach using two recurrent neural networks (RNNs) to predict the remaining range of BEVs and the minimum charge required to safely complete a trip. Each RNN has two outputs that can be used for statistical analysis to account for uncertainties; the first loss function leads to mean and variance estimation (MVE), while the second results in bounded interval estimation (BIE). These outputs of the proposed RNNs are then used to predict the probability of a vehicle completing a given trip without charging, or if charging is needed, the remaining range and minimum charging required to finish the trip with high probability. Training data was generated using a low-order physics model to estimate vehicle energy consumption from historical drive cycle data collected from medium-duty last-mile delivery vehicles. Here, the proposed method demonstrated high accuracy in the presence of day-to-day route variability, with the root-mean-square error (RMSE) below 6% for both RNN models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

AN APPROACH TO BRINGING AUTOMATED FAULT DETECTION AND DIAGNOSIS (AFDD) TOOLS FOR HVAC&R INTO THE MAINSTREAM

Heating, ventilation and air-conditioning (HVAC) systems can consume over 5 quads of energy annually, representing 30% of energy consumption in the U.S. in commercial buildings. Additionally, commercial refrigeration (R) systems add about 2 quads to commercial buildings energy consumption. Most HVAC systems have one or more faults (low/high refrigerant charge, valve leakage, condenser/evaporator fouling, filter/dryer restriction, economizer faults, controls faults) that result in increased energy consumption. Automated fault detection and diagnosis (AFDD) tools have been developed to address this national issue and many tools are commercially available. AFDD tools have the potential to save considerable energy for existing commercial RTUs, chillers and refrigeration systems. These devices can be used for both retro commissioning, and, when faults are addressed, continuous commissioning as well. However, there appears to be multiple market barriers for this technology. A key market barrier for this technology is the lack of awareness of AFDD products among potential customers. Most HVAC contractors are not familiar with the latest AFDD technologies and HVAC technicians lack skills regarding these technologies. Quantifying potential benefits to building owners is difficult since there are several FDD tools with varying capabilities. For instance, there are several FDD products ranging from handling just economizer faults to those that also handle full-blown refrigerant-side and air-side faults. Methods/algorithms used in FDD vary significantly. Even though there are efforts to develop standards, currently there are no standards/methods to define functions, capabilities, accuracy, and reliability of FDD tools. Moreover, most of the commercial AFDD tools have not been verified in the field independently. This paper presents a comprehensive approach to bringing HVAC AFDD tools into the mainstream. The approach involves demonstrating ten commercially available tools at ten different sites, independent testing and evaluation of the FDD tools, communication with various stakeholders, identifying market barriers, and assisting utility companies in developing incentive programs. This paper presents selection of AFDD tools, ite identification, and field testing and evaluation method.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

RouteE API

This is the API endpoint for RouteE energy prediction, which can be used to get both single vehicle link or route energy estimates and transportation network-wide energy consumption estimates for a variety of vehicles. This enables external researchers and transportation engineers to access and utilize NREL's growing library of pre-trained vehicle models for prediction of transportation energy consumption. This API provides three endpoints: • /route: Energy estimation of a vehicle over a planning link or sequence of links (route). • /network: Network-wide estimation of energy consumption for all vehicle traffic in the desired area. • /compass: Energy-optimal “eco-routing” between input origin and destination coordinates (Currently in beta for Denver metro area only).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

RouteE API

This is the API endpoint for RouteE energy prediction, which can be used to get both single vehicle link or route energy estimates and transportation network-wide energy consumption estimates for a variety of vehicles. This enables external researchers and transportation engineers to access and utilize NREL's growing library of pre-trained vehicle models for prediction of transportation energy consumption. This API provides three endpoints: - /route: Energy estimation of a vehicle over a planning link or sequence of links (route). - /network: Network-wide estimation of energy consumption for all vehicle traffic in the desired area. - /compass: Energy-optimal “eco-routing” between input origin and destination coordinates (Currently in beta for Denver metro area only).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Implications of Sustainability for the United States Light-Duty Transportation Sector

Climate change is a problem that must be solved. The primary cause of this problem is burning of fossil fuels to generate energy. A dramatic reduction in carbon emissions must happen soon, and a significant fraction of this reduction must come from the transportation sector. This paper reviews existing literature to assess the consensus of the scientific and engineering communities concerning the potential for the United States' light-duty transportation sector to meet a goal of 80 percent reduction in vehicle emissions and examine what it will take to meet this target. It is unlikely that reducing energy consumption in just vehicles with gasoline-based internal combustion drivetrains will be sufficient to meet GHG emission-reduction targets. This paper explores what additional benefits are possible through the adoption of alternative energy sources, looking at three possible on-vehicle energy carriers: carbon-based fuels, hydrogen, and batteries. potential for the United States' light-duty transportation sector to meet a goal of 80 percent reduction in vehicle emissions and examine what it will take to meet this target. It is unlikely that reducing energy consumption in just vehicles with gasoline-based internal combustion drivetrains will be sufficient to meet GHG emission-reduction targets. This paper explores what additional benefits are possible through the adoption of alternative energy sources, looking at three possible on-vehicle energy carriers: carbon-based fuels, hydrogen, and batteries.

33 ADVANCED PROPULSION SYSTEMS↗

Isolation of Battery Chargers Integrated Into Printed Circuit Boards

Present test procedures developed by the Federal Government (10 CFR Part 430 “Energy Conservation Program for Consumer Products”) to measure the energy consumption of battery chargers provide no method for the isolation of input power for battery chargers that have been integrated into printed circuit boards internal to electronic equipment. This prevents the measurement of Standby and Off Mode energy consumption. As a result, the energy consumption of battery chargers integrated into the printed circuit board cannot be measured.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

BLEMS (award #DE-EE0004019) Final Report

This project focused on the development and testing of a non-intrusive “bolt-on” solution called the Building Level Energy Management System (BLEMS) which reduces day-to-day electric energy consumption by at least 20% while maintaining or improving occupant comfort. BLEMS learns occupants’ energy usage behavior, and comfort preferences, as well as building system behavior and uses this information to reduce energy consumption and related greenhouse gas emissions, while simultaneously meeting occupants’ comfort and building usage needs (i.e., day-to-day energy usage goals, demand response energy usage levels, etc.). In BLEMS, humans and building systems and devices interact ubiquitously in real time through an integrated sensor and control system for reduced building electricity consumption. The solution enables bidirectional communication between building systems and occupants, obtains occupant input on comfort level preferences, and operates the building based on measured system response, occupant feedback, and predicted occupancy. Although designed to be used in any building, we focused on commercial buildings as they are a major consumer of HVAC power.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using Field-Metered Data to Quantify Annual Energy Use of Residential Portable Unit Dehumidifiers

The U.S. Energy Information Administration (EIA) reports that space heating and cooling no longer account for the majority of all residential energy consumption (they represented 47.7 percent in 2009). According to EIA, energy consumption for appliances, lighting, and electronics not only represents the majority of residential consumption, but continues to rise. Some of the decline in energy use for space heating and cooling may be attributable to better-insulated structures and population shifts to warmer climates. Those same factors may be contributing to an increased reliance on space-conditioning appliances, specifically dehumidifiers. Additionally, as the world’s climate changes, it is expected that absolute humidity will rise along with temperature. A recent study reports that continued climate warming will place significant limitations on human activity in typically hotter, more humid environments. Increased human discomfort may drive an even greater use of dehumidifiers and a resulting increase in residential energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy-Efficient and Comfortable Buildings through Multivariate Integrated Control (ECoMIC)

This project aims to develop an integrated control solution for enhanced energy efficiency and user comfort in commercial buildings. The developed technology is a zone-based control framework that minimizes energy usage while maintaining occupants’ visual and thermal comfort through control of electric lights, motorized venetian blinds and thermostats. The control framework is designed following a modular, scalable and flexible architecture to facilitate easy integration with exiting building management systems. The control framework contains two key algorithms: 1) the lighting load balancing algorithm and 2) the thermostat control algorithm. The lighting load balancing algorithm adopts a model-based closed-loop control approach to determine the optimal electric light and venetian blind settings. It is formulated into an optimization problem with minimizing lighting-related energy consumptions as the objective and delivering adequate task light and preventing daylight glare as the constraints. The thermostat control algorithm is based on a well-established thermal comfort model and formulated as a root-finding problem to dynamically determine the optimal thermostat setpoint for both energy savings and improved thermal comfort. To address building-wide scalability, a system architecture was developed for the zone-based control technology. Three levels of services are defined in the architecture: external services, facility level services and zone level services. The zone-level service includes the control algorithms described above as well as the corresponding interfaces, profiles, sensors and actuators to realize the zone controller. The facility level services connect to the zones through a backbone network, handle supervisory level information and controls, and thus facilitate building-wide scalability. The external services provide communication capability to entities outside of the building for grid interaction and remote access. Various aspects of the developed control technology were evaluated and verified through both simulations and testbed implementations. Simulations coupling a DOE medium office reference building in EnergyPlus building simulation software and a prototype controller in Matlab were performed. During summer time in a mixed-humid climate zone, the simulations revealed reductions of 27% and 42% in electric lighting load and cooling load, respectively, when compared to an advanced base case with daylight dimming and blinds automatically tilted to block direct sun. Two single-room testbeds were established. The testbed at Philips Lighting business building (Rosemont, IL) was designed for quantifying energy performance of integrated controls. This particular implementation achieved 40% and 79% savings on lighting and HVAC energy, respectively, compared to a relatively simple base case operated on predefined schedules. While the resulting energy savings was very encouraging, it should be noted that there may be several caveats associated with it. 1) The test was run during late spring and early summer, and the savings numbers might not be directly used to extrapolate the annual energy savings. 2) Due to the needs for separate control and metering of the small-scale demonstrator within a large building, the HVAC system, hence the corresponding savings, did not represent a typical energy code-compliant design. 3) The light level in the control case was regulated at a particular setpoint, which was lower than then the full-on light level in the base case, and the savings resulted from tuning down the light level to the setpoint was not attributable to the contribution of the developed technology. The testbed at the Lawrence Berkeley National Laboratory (Berkeley, CA) specifically focused on glare control integration, and has demonstrated the feasibility and capability of the glare detection and prevention technique. While the short one-month test in this testbed provided a functional indication of the developed technology, and it would require at least a full solstice-to-solstice cycle to ruinously quantify the performance, which was not possible within the project timeframe. There are certain limitations inherited from the operational assumptions, which could potentially affect the effectiveness and applicability of the developed control technologies. The system takes a typical ceiling-mounting approach for the photosensor locations, and therefore, the control performance relies on proper commissioning or the built-in intelligence of the photosensor for pertinent task light level estimations. For spaces where daylight penetration diminishes significantly deeper into the zone, certain modification to the control algorithms is required to accommodate multiple lighting control subzones and the corresponding sensors for providing a more uniform light level across the entire zone. Integrated control of visual and thermal comfort requires the lighting control zone and thermal control zone to coincide with each other. In other words, the area illuminated by a lighting circuit needs to be the same area served by the thermostat. Thus, the original zoning will potentially constrain the applicability of this technology in retrofitting projects. This project demonstrated the technical feasibility of a zone-based integrated control technology. From the simulation results and testbed implementations, up to 60% lighting energy savings in daylit areas relative to a “no-controls” case can easily be achieved. A 20% reduction of whole building energy consumption is also attainable. In the aspect of occupant comfort, the testbed demonstrated the ability to maintain specified light level on the workplane while promptly mitigate daylight glare 90% of the time. The control system also managed to maintain the thermal environment at a comfortable level 90% of the time. The aspect of system scalability was guaranteed by the system architecture design, based on which the testbeds were instantiated. Analysis on the aspect of economic benefit has yielded an about 6-year payback time for a medium-sized building, including the installation of all hardware and software, such as motorized blinds and LED luminaires. The payback time can be significantly reduced if part of the hardware is already in place for retrofitting projects. It needs to be noted that since the payback analysis was partly based on the testbed performance results, it is constrained by the caveats associated with the testbed implementations. The main uncertainty lies in the contribution from the space conditioning energy savings as it was non-trivial to realistically configure a room-size HVAC system for directly extrapolating whole-building HVAC energy savings. It is recommended to further evaluate the developed technology at a larger scale, where the lighting and HVAC energy consumption can be realistically measured at the building level, to more rigorously quantify the performance potentials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lifetime Energy and Environmental Impacts of Insulation Materials in Commercial Building Applications – Assessment Methodology and Sample Calculations

Application of insulation materials to building envelopes is a relatively easy and effective way of reducing energy consumption for space conditioning and, consequently, limiting the negative environmental impacts from the buildings sector. While insulation materials have a positive impact on the environment by reducing energy consumption in buildings, they also have some negative environmental impacts associated with their ‘embodied energy’. The total lifetime environmental impacts of insulation materials are a summation of: (1) direct impacts due to their embodied energy, and (2) indirect or environmental impacts avoided due to the reduced building energy consumption. It is important to identify insulation materials for buildings that will result in minimum negative environmental impacts. The objective of this project was to perform an assessment of the lifetime energy and environmental impacts of building insulation materials based on a previously developed protocol. The developed protocol was used for calculating the lifetime environmental impacts of selected insulation materials. Two Excel-based tools were developed: 1) to calculate embodied energy and GWP (equivalent CO 2 emissions) of insulation materials, and 2) to estimate energy savings and avoided environmental impacts due to the use of insulation materials in buildings. The direct environmental impacts were estimated using data from existing literature and life cycle analysis software; the indirect impacts were based on simulations of prototype whole-building models. This report summarizes the simulation study based on the recommendations of a previously developed protocol (A protocol for lifetime energy and environmental impact assessment of building insulation materials) by Shrestha et al., 2014. It also discusses a simplified algorithm based technique developed to quantify energy savings potential without requiring whole-building energy simulations. The report describes a proposed protocol that is intended to provide a comprehensive list of factors to be considered in evaluating the direct and indirect environmental impacts of building insulation materials, as well as detailed descriptions of standardized calculation methodologies to determine those impacts. Estimating the energy savings impact of insulation materials for the buildings in United States was an important aspect of this recommendation and comparative analyses of selected insulation materials were performed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using Field-Metered Data to Quantify Annual Energy Use of Portable Air Conditioners

As many regions of the United States experience rising temperatures, consumers have come to rely increasingly on cooling appliances (including portable air conditioners) to provide a comfortable indoor temperature. Home occupants sometimes use a portable air conditioner (PAC) to maintain a desired indoor temperature in a single room or enclosed space. Although PACs in residential use are few compared to centrally installed and room air conditioning (AC) units, the past few years have witnessed an increase of PACs use throughout the United States. There is, however, little information and few research projects focused on the energy consumption and performance of PACs, particularly studies that collect information from field applications of PACs. The operation and energy consumption of PACs may differ among geographic locations and households, because of variations in cooling load, frequency, duration of use, and other user-selected settings. In addition, the performance of building envelope (thermal mass and air leakage) as well as inter-zonal mixing within the building would substantially influence the ability to control and maintain desirable indoor thermal conditions. Lawrence Berkeley National Laboratory (LBNL) conducted an initial field-metering study aimed at increasing the knowledge and data related to PAC operation and energy consumption in the United States.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Wireless Sensor Node Power Profiling Based on IEEE 802.11 and IEEE 802.15.4 Communication Protocols. Modeling and Simulation

Most wireless sensor network (comprising of thousands of WSNs) applications require operation over extended periods of time beginning with their deployment. Network lifetime is extremely critical for most applications and is one of the limiting factors for energy-constrained networks. Based on applications, there are wide ranges of different energy sources suitable for powering WSNs. A battery is traditionally used to power WSNs. The deployed WSN is required to last for long time. Due to finite amount of energy present in batteries, it is not feasible to replace batteries. Recently there has been a new surge in the area of energy harvesting were ambient energy in the environment can be utilized to prolong the lifetime of WSNs. Some of the sources of ambient energies are solar power, thermal gradient, human motion and body heat, vibrations, and ambient RF energy. The design and development of TEGs to power WSNs that would remain active for a long period of time requires comprehensive understanding of WSN operational. This motivates the research in modeling the lifetime, i.e., power consumption, of a WSN by taking into consideration various node and network level activities. A WSN must perform three essential tasks: sense events, perform quick local information processing of sensed events, and wirelessly exchange locally processed data with the base station or with other WSNs in the network. Each task has a power cost per unit tine and an additional cost when switching between tasks. There are number of other considerations that must also be taken into account when computing the power consumption associated with each task. The considerations includes: number of events occurring in a fixed active time period and the duration of each event, event-information processing time, total communication time, number of retransmission, etc. Additionally, at the network level the communication of information data packets between WSNs involves collisions, latency, and retransmission, which result in unanticipated power losses. This report focuses rigorous stochastic modeling of power demand for a schedule-driven WSN utilizing Institute of Electrical and Electronics Engineers 802.11 and 802.15.4 communication protocols. The model captures the generic operation of a schedule-driven WSN when an external event occurs, i.e., sensing, following by processing, and followed by communication. The report will present development of an expression to compute the expected energy consumption per operational cycle of a schedule-driven WSN by taking into consideration the node level activities, i.e., sensing and processing, and the network level activities, i.e., channel access, packet collision, retransmission attempts, and transmission of a data packet.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High Efficiency, Low Emission Refrigeration System

Supermarket refrigeration systems account for approximately 50% of supermarket energy use, placing this class of equipment among the highest energy consumers in the commercial building domain. In addition, the commonly used refrigeration system in supermarket applications is the multiplex direct expansion (DX) system, which is prone to refrigerant leaks due to its long lengths of refrigerant piping. This leakage reduces the efficiency of the system and increases the impact of the system on the environment. The high Global Warming Potential (GWP) of the hydrofluorocarbon (HFC) refrigerants commonly used in these systems, coupled with the large refrigerant charge and the high refrigerant leakage rates leads to significant direct emissions of greenhouse gases into the atmosphere. Methods for reducing refrigerant leakage and energy consumption are available, but underutilized. Further work needs to be done to reduce costs of advanced system designs to improve market utilization. In addition, refrigeration system retrofits that result in reduced energy consumption are needed since the majority of applications address retrofits rather than new stores. The retrofit market is also of most concern since it involves large-volume refrigerant systems with high leak rates. Finally, alternative refrigerants for new and retrofit applications are needed to reduce emissions and reduce the impact on the environment. The objective of this Collaborative Research and Development Agreement (CRADA) between the Oak Ridge National Laboratory and Hill Phoenix is to develop a supermarket refrigeration system that reduces greenhouse gas emissions and has 25 to 30 percent lower energy consumption than existing systems. The outcomes of this project will include the design of a low emission, high efficiency commercial refrigeration system suitable for use in current U.S. supermarkets. In addition, a prototype low emission, high efficiency supermarket refrigeration system will be produced for laboratory and field testing. Laboratory and field testing will demonstrate the high energy efficiency and low environmental impact of the refrigeration system developed in this project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Integrated Die Casting Process for Large Thin-Wall Magnesium Applications

The purpose of this project was to develop a process and product which would utilize magnesium die casting and result in energy savings when compared to the baseline steel product. The specific product chosen was a side door inner panel for a mid-size car. The scope of the project included: re-design of major structural parts of the door, design and build of the tooling required to make the parts, making of parts, assembly of doors, and testing (both physical and simulation) of doors. Additional work was done on alloy development, vacuum die casting, and overcasting, all in order to improve the performance of the doors and reduce cost. The project achieved the following objectives: 1. Demonstrated ability to design a large thin-wall magnesium die casting. 2. Demonstrated ability to manufacture a large thin-wall magnesium die casting in AM60 alloy. 3. Tested via simulations and/or physical tests the mechanical behavior and corrosion behavior of magnesium die castings and/or lightweight experimental automotive side doors which incorporate a large, thin-wall, powder coated, magnesium die casting. Under some load cases, the results revealed cracking of the casting, which can be addressed with re-design and better material models for CAE analysis. No corrosion of the magnesium panel was observed. 4. Using life cycle analysis models, compared the energy consumption and global warming potential of the lightweight door with those of a conventional steel door, both during manufacture and in service. Compared to a steel door, the lightweight door requires more energy to manufacture but less energy during operation (i.e., fuel consumption when driving vehicle). Similarly, compared to a steel door, the lightweight door has higher global warming potential (GWP) during manufacture, but lower GWP during operation. 5. Compared the conventional magnesium die casting process with the “super-vacuum” die casting process. Results achieved with cast tensile bars suggest some improvement in tensile properties with vacuum casting. Plant trials with large castings revealed cavity fill issues attributed to cooling and partial solidification of metal in the shot sleeve while waiting for vacuum to be established in the die cavity. 6. Developed age-hardenable Mg-based alloys as potential alternatives to the AM60 and AZ91 alloys typically used in automotive applications. Mg-7%Al-based alloys having Sn or Sn+Si additions exhibited significant age hardening, but more work is needed to demonstrate significant improvement in tensile properties. Corrosion behavior of these alloys is between those of AM60 and AZ91 alloys. 7. Evaluated the die casting of magnesium directly onto either steel or aluminum tubes as a potential process to make large lightweight subassemblies. Samples were free of gross defects, but additional work is needed to increase the interfacial shear strength. Overall, the project demonstrated that an automotive door-in-white design incorporating a die cast magnesium inner panel and a stamped aluminum outer panel can achieve approximately 50% mass reduction compared to the stamped steel baseline door-in-white. This leads to reduced energy consumption when driving the vehicle, which should more than offset the increased embedded energy of manufacture associated with the lighter metals. However, additional design work would be needed in order to meet the mechanical performance required of a door. Development of high-strength, high-ductility magnesium alloy castings would help make this technology more attractive for potential use in the side doors on automobiles. Also, increased use of recycled magnesium and aluminum would reduce the embedded energy and greenhouse gas emissions associated with the manufacture of this type of lightweight door. Commercialization planning of the type of lightweight door technology addressed in this project would be contingent upon the doors meeting all technical performance requirements of the car maker. The specific lightweight door developed in this project didn’t meet some of those requirements, but a preliminary business case study was conducted anyhow. This study considered the ratio of cost increase to mass decrease when the lightweight door is compared to a baseline steel door. The ratio was found to be in an acceptable range for some vehicle programs, especially if the number of such vehicles to be produced is equal to or slightly less than the estimated 250,000-shot life of the die set. This would allow for the investment in the dies to be spread across many parts and thereby help minimize the cost increase.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Establishing a commercial building energy data framework for India

Buildings account for over 40% of the world’s energy consumption and are therefore a key contributor to a country’s energy as well as carbon budget. Understanding how buildings use energy is critical to understanding how related policies may impact energy use. Data enables decision making, and good quality data arms consumers with the tools to compare their energy performance to their peers, allowing them to differentiate their buildings in the real estate market on the basis of their energy footprint. Good quality data are also essential for policy makers to prioritize their energy saving strategies and track implementation. The United States’ Commercial Building Energy Consumption Survey (CBECS) is an example of a successful data framework that is highly useful for governmental and nongovernmental initiatives related to benchmarking energy forecasting, rating systems and metrics, and more. The Bureau of Energy Efficiency (BEE) in India developed the Energy Conservation Building Code (ECBC) and launched the Star Labeling program for a few energy-intensive building segments as a significant first step. However, a data driven policy framework for systematically targeting energy efficiency in both new construction and existing buildings has largely been missing. There is no quantifiable mechanism currently in place to track the impact of code adoption through regular reporting/survey of energy consumption in the commercial building stock. In this paper we present findings from our study that explored use cases and approaches for establishing a commercial buildings data framework for India.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Interaction between Heat Pump Water Heaters or Other Internal Point Source Loads and a Central Heating System

Water heating represents approximately 18% of residential energy consumption, or 4.6 quadrillion Btus of source energy use annually (EIA 2009). Heat pump water heaters (HPWHs) offer an efficient option for residential water heating, with the ability to reduce water heating energy consumption by up to 63%. Previous research has demonstrated the laboratory performance of HPWHs and has shown savings of 43 to 62% on water heating energy consumption are possible, based on field tests (Ecotope 2015). In order to achieve such high efficiencies, HPWHs employ a refrigeration cycle to move heat from the ambient air into the water. Therefore, when HPWHs are installed in conditioned space, they will remove heat from that space which can help the HVAC system in the cooling season and require additional energy from the HVAC system in the heating season. This project provides an unbiased evaluation of the space conditioning interactions between a HPWH and the heating system in several locations throughout the home to further our understanding of the impact that HPWHs have on space conditioning loads. This report explores the HPWH interaction factor from several perspectives: (1) a theoretical analysis, (2) a review of previous literature, and (2) an experimental assessment. The experiments were conducted in PNNL’s side-by-side Lab Homes, which provide a platform for evaluating energy-saving and grid-responsive technologies in a controlled environment. The PNNL Lab Homes are two factory-built homes installed on PNNL’s campus in Richland, Washington. The homes represent existing homes, which account for approximately 99% of occupied homes in the U.S. These 1500 ft2 homes have three bedrooms, two bathrooms, and are equipped with 7.7 HSPF heat pump and an electric forced air furnace. Both homes have R-22 floors, R-11 walls and R-22 ceiling insulation levels, with double-pane clear glass windows. The results of this experiment verified that the energy use of the HVAC system increases as a point source cooling load, like a HPWH, is moved closer to the thermostat. The opposite is also true, as a point source heating load is moved closer to the thermostat, the heating load decreases. The results show between 30-40% difference between the interaction that this type of load has when it is placed in the master bathroom compared to the living room for the PNNL Lab Homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial Building Technology Demonstration (Final Scientific/Technical Report)

The background for this project was a unique and innovative concept that had been proposed and demonstrated by enVerid Systems, reducing the energy consumption in HVAC systems in commercial and public buildings by up to 50% at peak loads. The concept involves selective scrubbing of gas contaminants from indoor air as a practical substitute for outside air ventilation, the latter being the conventional practice today. This scrubbing enables recycling of most of the indoor air and significantly decreasing the amount of outside air, resulting in a reduced HVAC load and commensurate energy savings for the facility. Key to our approach is low cost scrubbing of all gas contaminants from indoor air using novel, efficient and regenerable sorbent materials. The total solution, labeled HLR (HVAC Load Reduction) is implemented by means of compact modules that can be retrofitted onto virtually any building, and utilizes novel sorbents that have been developed and brought to scale production by enVerid. Although the technology had been deployed and demonstrated, the US commercial building and HVAC markets, famously conservative with respect to innovation and new technologies, had yet to embrace the idea or the product. The overarching goal of the project was to help overcome market hesitancy and enable widespread adoption, by creating a critical mass of success stories across different regions and building types, all under oversight and verification of the DOE and NREL, to ensure credibility and accuracy. The project, overall, was a resounding success. Several installations were deployed and tested comprehensively for the impact on both energy consumption and indoor air quality, and results were not only excellent, but quantitatively in line with expectations. A total number of eight (8) installations were attempted, with 2 aborted due to building issues. Of the six successful installations, however, complete M&V was performed by NREL on 2 (Miami and NYC) and partial analysis on a third site (ArcBest), and these three, along with their results, were therefore presented from a financial and reporting standpoint. Although the number of case studies fell short of the original target of 10, we nevertheless had excellent demonstrations in vastly different climate zones: Southeast, Northeast and Midwest, and in very different building types. This included a modern high-rise office building in New York City and a University Campus health center in Miami, and a mid-rise high-density office in Arkansas. The cooling load reduction was shown to be significant, averaging 37% during the final cooling season in the Miami site. In the NYC site, the cooling energy savings were generally less, at around 12%, as expected. While this is a lower number for average/total savings, two comments are important to note: (i) the outside airflow (OA) reduction was not consistent during the data collection period, at least in part understating the attainable savings through incorrect measurement of the “high energy” reference state; and (ii) the peak impact in NYC is almost certainly as high as Miami, with critical ramifications for peak load reduction and equipment downsizing ability. Importantly, the measured energy savings in all locations were related to the outdoor climate conditions and the actual achievable reduction in outside air, very much in line with models and calculations; this leaves us with increased confidence in our understanding of the interaction between the technology and the building, and our ability to project the impact of this innovation in the future, through broad adoption. Simply put: the energy savings and load reduction impact of the HLR solution has been confirmed quantitatively. The results also confirmed the air quality objective. This may be even more significant, in that air quality is more complex and harder to measure and quantify, and the performance of the HLR as an air scrubber is the linchpin of the entire solution. In all sites, indoor air quality met or exceeded the required parameters, in terms of achieving the target (low) levels of indoor pollutants. Furthermore, the concentrations of outdoor sourced pollutants were markedly lower, as expected, mostly due to the reduction in outside air intake although in part also due to the scrubbing. The success was not immediate nor easy, and early challenges with the systems, especially (but not only) around controls and communication, caused delays in commissioning and undermined some of our M&V schedules. The good news is no fundamental issues were encountered and the number of such glitches was declining quickly by the end of the project. Other challenges had to do with coordinating the control of the building OA dampers, which the HLR needs to have in order to deliver the load reduction, but which the facility manager controls regularly and independently. This is not necessarily a problem for normal HLR operation but interferes with accurate M&V, where switching OA settings back and forth on a precise timetable is essential for clean data. The project provided valuable experience in retrofitting buildings that had been originally designed to operate with less recirculation and more outside air, and some key learnings related to the cyclical regeneration of the sorbents in the operational environment of the building. Some of these learnings gave already been incorporated into ongoing improvements in the design of the HLR module as well as the software that is used to control its operation. The cost and time of retrofit installations is much better understood; so is the test and balance procedure of the building that determines the available range of outside air reduction, which in turn determines the amount of load reduced. We had also implemented at least one annual cycle of sorbent cartridge replacement in the field, after which we tested the used sorbent to assess the rate of degradation of sorbent potency – an important factor affecting the long-term economics of HLR deployments. A notable shortfall of the project, other than the fact that the number of sites was below target, was that we had not (yet) completed testing to measure and verify (M&V) the winter energy savings. This is primarily due to late start on the NYC sites (Miami does not portend any heating savings associated with reduced outside air), combined with the issues of OA damper control. It is by no means suggested that such savings cannot be captured, only that the M&V with respect to winter in NYC has been incomplete. The value of this project and its interest to the general public are hard to overstate. The case studies created from Miami and especially from NYC have, without a doubt, opened up the interest of the broad HVAC industry to HLR in the past year. Major manufacturer reps have signed up to represent and promote the product, and dozens of top tier engineering consultants have introduced HLR as a base of design in upcoming construction and renovation projects – precisely the overarching goal of this project. These would not have happened without the highly visible installation in NYC and its ultimately satisfied customer. Furthermore, the DOE itself issued a report in late 2017 analyzing hundreds of candidate technologies for reducing energy consumption in HVAC; remarkably, the budding HLR solution ranked among the top 3(!); no doubt, its status as a viable and significant contender on this list is informed by the success of these demonstrations. And furthermore, in the wake of these demos, several major energy utilities, led by ConEdison in NYC, have endorsed the HLR solution and now routinely provide substantial cash rebates for customers choosing to incorporate the HLR in their buildings and reap the benefit of the reduced peak load as well as reduced cumulative energy demand. Last but not least, in January of 2019, as this report was being written, the HLR module won the AHR Expo Innovation Award for Green Buildings and, remarkably, the prestigious and only Product of the Year 2019, being selected by an independent professional panel of judges from AHR and ASHRAE. Given the confirmation of the enormous energy saving potential of HLR in widescale deployment, as well as ancillary but significant benefits in terms of equipment downsizing and indoor air quality, the benefit of this effort to the public speaks for itself. Accelerating adoption of HLR, without dependence on subsidies and driven by the private sector, is well under way. There is still much work to be done in terms of educating the HVAC and construction ecosystems and improving the product’s robustness and simplicity, to further facilitate the adoption of this technology and the capture of its potential value. But the American public will greatly benefit both directly and indirectly in the immediate future and beyond.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The effect of linear regression modeling approaches on determining facility wide energy savings

Holistic energy management system business practices, such as the framework detailed in ISO 50001 – Energy management system, requirements and guidance for use , are centrally based upon the concept of energy performance improvement. For the purposes of ISO 50001, energy performance improvement can be determined for boundaries and following a process that is best suited for the implementing organization. Many organization and government ISO 50001 based programs, including the United States Department of Energy Superior Energy Performance (SEP) program, find value in demonstrating organizational energy performance improvement as the difference in energy consumption between two time periods within physically defined facility-boundaries. To make the difference in energy consumption for the two time periods meaningful, the amount of energy consumed must be adjusted to account for relevant variables. Relevant variables, such as metrics of production and weather conditions, affect directly the amount of energy consumed but are independent of the facility’s energy performance. Therefore, it is crucial to adjust the observed energy consumption by the relevant variables identified by the facility, so that the energy savings resulted from the energy performance improvement actions can be isolated and determined, which is the purpose of this program.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗