Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “clamp”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Miniature Release Mechanism or Diminutive Assembly for Nanosatellite Deployables (DANY)

Miniature release mechanisms constrain objects, such as deployables during the launch of space vehicles, such as small satellites and nanosatellites, and enable the release of the objects once a desired destination is reached by the space vehicle. Constraint and release of the objects are achieved by providing a secure threaded interface that may be released by the release mechanisms. The release mechanisms include a housing structure; a release block can include a threaded interface; one or more retracting pins; one or more release springs; a breakable link, such as a plastic link; a cable harness clamp; and a circuit board. The release mechanism can be 0.1875 inches (approximately 4.8 mm) thick.

Santos Soto, Luis H.↗

Aligned and Electrospun Piezoelectric Polymer Fiber Assembly and Scaffold

A method of manufacturing and/or using a scaffold assembly for stem cell culture and tissue engineering applications is disclosed. The scaffold at least partially mimics a native biological environment by providing biochemical, topographical, mechanical and electrical cues by using an electroactive material. The assembly includes at least one layer of substantially aligned, electrospun polymer fiber having an operative connection for individual voltage application. A method of cell tissue engineering and/or stem cell differentiation that uses the assembly seeded with a sample of cells suspended in cell culture media, incubates and applies voltage to one or more layers, and thus produces cells and/or a tissue construct. In another aspect, the invention provides a method of manufacturing the assembly including the steps of providing a first pre-electroded substrate surface; electrospinning a first substantially aligned polymer fiber layer onto the first surface; providing a second pre-electroded substrate surface; electrospinning a second substantially aligned polymer fiber layer onto the second surface; and, retaining together the layered surfaces with a clamp and/or an adhesive compound.

Scott Carnell, Lisa A.↗

An Efficient Inverse Finite Element Method for Shape and Stress Sensing of Laminated Composite and Sandwich Plates and Shells

The inverse Finite Element Method (iFEM) is a revolutionary methodology for real-time reconstruction of full-field structural displacements and stresses in structures that are instrumented with strain sensors. This inverse problem is commonly referred to as shape and stress sensing, which is well-recognized as an enabling technology for structural health monitoring systems. In this study, an improved iFEM formulation is proposed for shape and stress sensing of laminated composite and sandwich plates and shells. The formulation includes the kinematics of a shear deformation plate theory known as Refined Zigzag Theory (RZT) as its baseline. The present iFEM formulation is based upon the minimization of a weighted-least-squares functional that uses the complete set of section strains of RZT. The improved iFEM methodology is applicable for shape and stress sensing of thin and moderately thick plate and shell structures involving a relatively small number of strain gauges. The main advantage of the current formulation is that highly accurate through-the-thickness distributions of displacements, strains, and stresses are attainable using an element based on simple C0-continuous displacement interpolation functions. A three-node inverseshell element, named i3-RZT, is developed. Two example problems are examined in detail: (1) a simply supported rectangular laminated composite plate and (2) a wedge structure with a hole near one of the clamped ends. For both problems, the experimental strain data are generated numerically by the direct finite element analysis using high-fidelity discretizations. These strains are then regarded as the experimental strains obtained from surface mounted strain gauges or embedded fiber Bragg grating (FBG) sensors. The numerical results demonstrate the superior capability and potential applicability of the i3- RZT/iFEM methodology for performing accurate shape and stress sensing of complex composite structures.

Kefal, Adnan↗

Geometry and Joint Systems for Lattice-Based Reconfigurable Space Structures

We describe analytical methods for the design of the discrete elements of ultralight lattice structures. This modular, building block strategy allows for relatively simple element manufacturing, as well as relatively simple robotic assembly of low mass density structures on orbit, with potential for disassembly and reassembly into highly varying and large structures. This method also results in a structure that is easily navigable by relatively small mobile robots. The geometry of the cell can allow for high packing efficiency to minimize wasted payload volume while maximizing structural performance and constructability. We describe the effect of geometry choices on the final system mechanical properties, manufacturability of the components, and automated robotic constructability of a final system. Geometry choices considered include building block complexity, symmetry of the unit cell, and effects of vertex, edge, and face connectivity of the unit cell. Mechanical properties considered include strength scaling, modulus scaling, and structural performance of the joint, including proof load, shear load, mass, and loading area; as well as validation and verification opportunities. Manufacturability metrics include cost and time, manufacturing method (COTS versus custom), and tolerances required. Automated constructability metrics include local effects of loads imparted to the structure by the robot and assembly complexity, encompassing the ability of the robot to clamp and number of placement motions needed for assembly.

Ochalek, Megan E.↗

Aligned and Electrospun Piezoelectric Polymer Fiber Assembly and Scaffold

A method of manufacturing and/or using a scaffold assembly for stem cell culture and tissue engineering applications is disclosed. The scaffold at least partially mimics a native biological environment by providing biochemical, topographical, mechanical and electrical cues by using an electroactive material. The assembly includes at least one layer of substantially aligned, electrospun polymer fiber having an operative connection for individual voltage application. A method of cell tissue engineering and/or stem cell differentiation that uses the assembly seeded with a sample of cells suspended in cell culture media, incubates and applies voltage to one or more layers, and thus produces cells and/or a tissue construct. In another aspect, the invention provides a method of manufacturing the assembly including the steps of providing a first pre-electroded substrate surface; electrospinning a first substantially aligned polymer fiber layer onto the first surface; providing a second pre-electroded substrate surface; electrospinning a second substantially aligned polymer fiber layer onto the second surface; and, retaining together the layered surfaces with a clamp and/or an adhesive compound.

Scott Carnell, Lisa A.↗

A Simple Control to Reduce the Voltage Stress of Non-Conducting Switches in Three-Level ANPC Converter

With the development of wide band-gap (WBG) technology, the switching speed of power semiconductor devices is increased, which makes circuits more sensitive to parasitics. For three-level active neutral point clamped (3L-ANPC) converters, the over-voltage of non-conducting switches can be an issue. This paper analyzes the multiple commutation loops in 3L-ANPC converter and summarizes the impact factors of the over-voltage for the non-conducting switch. It is found that the nonlinearity of the output capacitance of the device can significantly influence the over-voltage. A simple control without introducing any additional hardware circuit is proposed to attenuate the impact of the nonlinearity. With the proposed control, the peak over-voltage of the non-conducting switch can be reduced significantly. Multi-pulse test is conducted for a 3L- ANPC converter built with silicon carbide (SiC) MOSFETs. The testing results show that the peak over-voltage decreases from 892 V to 624 V with the proposed control. More detailed analysis and experimental results will be provided in the final paper.

SiC MOSFET↗

Modeling of Multi-Loops Related Device Turn-On Overvoltage in 3L-ANPC Converters

The analytical model for the device drain-source turn-on overvoltage in three-level active neutral point clamped (3L-ANPC) converters is established in this paper. Considering the two commutation loops in the converter, the relationship between the overvoltage and the loop inductances is evaluated. The line switching frequency device usually exhibits higher overvoltage, while the high switching frequency device is not strongly influenced by the multiple loops. A 500 kVA 3L-ANPC converter using SiC MOSFETs is tested, and the model is verified with the experimental results.

SiC MOSFET↗

Design of Low Inductance Busbar for 500 kVA Three-Level ANPC Converter

The adoption of SiC devices in high power applications enables higher switching speed, which requires lower circuit parasitic inductance to reduce the voltage overshoot. This paper presents the design of a busbar for a 500 kVA three-level active natural clamped converter. The layout of the busbar is discussed in detail based on the analysis of the multiple commutation loops, magnetic cancelling effect, and DC-link capacitor placement. The loop inductance of the designed busbar is verified with simulation, impedance measurements and converter experiment. The results can match with each other and the inductances of small and large loop are 6.5 nH and 17.5 nH respectively, which is significantly lower than the busbars of NPC type converters in other references.

SiC MOSFET↗

Improving Structural Test and Analysis Correlation Using Digital Image Correlation Boundary Measurements

Simplified idealizations, such as clamped or simply supported, are commonly used as support boundary conditions in modeling and analysis of tested aerospace structures. However, these simplifications are not always appropriate and characterization of the response of non-rigid boundaries is often required to improve test and analysis correlation. While e analysis models are typically modified to better represent the test, this modification is often not practical due to the complexities of the boundary response. A study is conducted to examine the use of digital image correlation (DIC) to measure the boundary support structure response and then to adjust the test data to remove the effects of the boundary response in order to improve test and analysis correlation. A high-aspect ratio composite wing test is the subject of the study. Three sources of boundary flexibility contributing to rigid body rotation of the test wing are identified and quantified using both DIC and conventional test data. The wing displacement test data are adjusted using DIC data for these sources. Wing displacement test data is also adjusted using direct measurement of wing rotation from a DIC system that monitored the top surface, root region of the wing, and using available conventional instrumentation. The adjusted data exhibits improved test and analysis correlation and demonstrated the benefit of using DIC along with conventional instrumentation to collect and interpret test data.

Andrew E Lovejoy↗

Creep Testing of Vectran Yarn

NASA and industry are developing inflatable space structures to provide deployable habitable volumes for future exploration missions in space and on the surface of the Moon and Mars. These structures must withstand the constant pressure loading of multi-year missions. These missions therefore require excellent creep resistance in the constituent cordage and webbings that provide the primary structure of the vessel, which is typically constructed using high-strength synthetic materials such as Vectran. Real-time and accelerated creep testing of Vectran webbings has been performed at NASA Langley Research Center (LaRC), however, acceptable correlation between the results of the two approaches has not yet been achieved. Given the additional complexity of the webbing architecture, creep testing at the yarn level is being studied to reduce the number of interacting properties and focus on the core creep behavior to see if better correlation can be achieved between real-time and accelerated tests. To achieve this objective a creep test stand that is able to support simultaneous testing of five Vectran yarns had been previously designed and built. The test stand utilizes two clamp-wrap grips to mount the yarn and has a 10:1 load ratio, via a lever-arm, henceforth, known as the lever-arm test stand. Real-time creep testing (without measuring the strain of the yarn) in this fixture produces yarn ruptures in the gauge section. However, a large scatter in the times to failure was seen in the results across multiple loading conditions. For example, a test at 70% of the ultimate tensile strength (UTS) was found to have specimens that failed within a matter of hours and others that took over 6 weeks to fail. Prior test data on Vectran webbings had indicated high variability in the material strength, leading to higher than average scatter in the creep testing of webbings, which could translate to the scatter in creep behavior at the yarn level as well. However, there was still the possibility that the lever-arm test stand was causing the high scatter in data; specifically, due to potential variability in the loading of each specimen. Therefore, an additional creep test setup was designed and built to attempt to determine if the large scatter in the results was due to inherent material properties, the lever-arm test stand, or both. The newly designed creep test stand, henceforth known as the conventional test stand, utilized the more typical method for creep testing which involved hanging a weight from the yarn with no additional load amplification. The conventional test stand was designed and fabricated in-house at LaRC. High speed cameras were used to validate that the specimens in the conventional test stand failed in the gauge section. Once it was determined that the conventional test stand would provide valid failures in the gauge section, creep tests on the Vectran yarns were run to compare to the lever-arm test stand results. Preliminary results for a 70% UTS creep test have some specimens failing within a number of hours and some failing in excess of 6 weeks. These results are similar to those seen on the lever-arm test stand, pointing towards a large variability inherent in the material. The poster/presentation will focus on the design, fabrication, and validation of the conventional test stand as well as present preliminary results comparing the creep data from the conventional and lever-arm test stands

creep testing↗

Rollable Corrugated Tubular Booms

A promising candidate for a new class of deployable composite boom is the COrrugated ROllable TUbular Boom (COROTUB), which is to be employed on future large space structures by the National Aeronautics and Space Administration (NASA). The COROTUB’s two corrugated thin shells form a closed section, which yields high bending and torsional stiffness, allowing for high dimensional stability. The corrugation geometry that dictates the boom cross-section shape was completely defined by closed-form analytical equations given a set of key design parameters. Parametric studies of two geometric variables were used to evaluate which parameters most influence the cross-section’s area moment of inertia and torsional constant. The number of corrugations, flattened height of the boom, and concave and convex corrugation radii were varied to study the complete boom design space. Deeper corrugations increased the local buckling (crimpling) loads of the thin-shell boom but reduced the area moment of inertia and therefore the global buckling load of the beam-column member, and thus a fine balance was sought. Finite element analyses of pure bending and compression load cases for short, 1.22-m-long fully-deployed booms ofeither the same size (flattened height) or similar inertia properties, were first carried out to efficiently study this design trade-off in detail.A second computational study evaluated the boom transition shape and the structural response of a 6-m-long partially-deployed boom, where the effects of partially bracing the root of the boom were also assessed. It was found that bracing length could greatly affect the strength and stiffness of this boom.Bracing type (as in the discrete number of clamps at the root) had no effect on stiffness, but particularly impacted strength for loading cases and boundary conditions that promoted the onset of local web buckling at the root. The corrugated designs were also found to improve, by as much as 20%, the boom bending and axial strength and boom transition length from flat to deployed when compared to a state-of-the-art boom alternative of the same size, for short bracing distances, such as those that would be required by small satellite applications. In addition, they showed a comparable structural response for longer bracing supports.

Booms↗

Experiences in the Development of the Mighty Worm

The field of adaptive structures has expanded dramatically during the past few years. Inch worm actuators are commercially available, but do not meet all the desired static and dynamic features in one actuator. The objective of the development of the Mighty Worm was to develop such an actuator. The Mighty Work actuator consists of a piezoelectric transducer, its housing, and two clamping devices. In operation, Mighty Worm either pushes or pulls a load.

actuators↗

Use of Mechanical Heat Switch to Speed up TVAC Transitions on Flight Hardware Below 200K

Spaceflight hardware that operates at temperatures well below room temperature usually require being well isolated from their warmer environment in order to manage thermal parasitics adequately. This is especially true for spaceflight systems that rely on passive cooling such as a radiator. During ground testing, this design configuration can be problematic for TVAC cycling between operational temperature extremes, since the hardware temperatures may move extremely slowly and lengthen the duration of an already expensive and heavily staffed system-level TVAC campaign. One of the challenges of using an external means of speeding up temperature transitions is that a TVAC campaign usually also requires the simulation of flight-like environments to validate the design, and introducing a test feature to speed up transitions can disrupt the system such that flight-like environments are not achievable. Such an approach was used for the L’Ralph instrument level TVAC test. L’Ralph is a passively cooled instrument on the Lucy mission with planned flyby’s of the Trojan asteroids around 5.5 AU. The optics and visible detector are cooled below 190K, and the IR detector is cooled below 110K. During instrument TVAC qualification testing, a mechanical motor-controlled heat switch uses clamping pressure via a vise-grip mechanism to achieve faster temperature transitions by increasing the conduction to a cold sink. The heat switch system then disengages and employs zero-Q controls to achieve flight-like thermal environments for thermal balance plateaus. Results from stand-alone testing of the heat switch are discussed, including correlated on/off ratios and the expected conductance across its operational temperature range. Test data from an instrument level TVAC that successfully utilized the heat switch are also shown.

Daniel G Bae↗

Remodeling BioSentinel’s Microbial Metabolism Measurement System

BioSentinel, the first biological CubeSat beyond low Earth orbit, will investigate how Saccharomyces cerevisiae responds to ionizing radiation using optical measurements of a colorimetric metabolic indicator dye (alamarBlue). To map optical data to more detailed metabolic measurements, a microbial culture system for ground testing was designed consisting of a 400 mL beaker and a rubber stopper with pass-through holes for its five sensor probes (electrical conductivity, pH, oxidation-reduction potential, dissolved oxygen, optical density). The initial design had several drawbacks. It was only partially reusable due to its one-time sealants: Teflon tape and parafilm. A steady increase in oxygen levels within the sensor’s testingdata indicated the design was not sufficiently airtight. Degradation of the rubber stopper’s elasticity due to sterilization and reinsertion of the probes led to poor robustness and eventual replacement. The vessel’s large headspace didn’t reproduce flight conditions and a large culture volume required more reagents. The system has been redesigned to contain a rigid, biocompatible polycarbonate disc lid that allows for threaded inserts. The culture vessel’s height will be reduced from 110 mm to 65 mm to decrease overhead space and material costs. A more reliable seal will be achieved with a gasket and clamps. The optical probe records absorbance at four wavelengths to characterize cell density and alamarBlue dye ratios. A pneumatically operated plunger draws media through the hollow interior of the probe. Currently, deformation of the silicone on the plunger causes asymmetrical movement and a drift from its initial state. Designs are being developed to limit the plunger’s travel for a more accurate measurement cycle. The remodeled system is under construction and will be tested for leaks and accuracy. The measurements collected will be used to provide additional insight into the optical data returned from the BioSentinel mission.

Astrobiology↗

Meteorite Sample Section Repair at NASA Johnson Space Center

Introduction: Meteorite thin and thick sections are routinely shipped from NASA Johnson Space Center to fulfill sample allocation requests from principle investigators around the world. Sections are also re-turned to JSC when researchers are finished studying them since, in most cases, they can be reused for other studies. The sections are very fragile unfortunately, and sometimes return to us needing repairs. The fol-lowing should give you an idea of how we repair sections here in the very lab where they were created. NOTE: Please do not attempt to repair ANSMET meteorite sections that are in your possession. We will perform the repairs for you at NASA JSC if you send the section back to us. Section Delamination: The majority of the meteorite sections that we produce here are secured to the glass slide using a high quality, two-part epoxy. Occasionally, we are asked to use superglue if the researcher wishes to dismount the section from the slide. Both epoxy and superglue are excellent adhesives, but they both tend to embrittle with time which results in delamination from the slide. Exposure to vacuum can also degrade the adhesion between the sample section and the glass slide. Repeated handling of the slide edges can accelerate delamination and, as a preventive measure, the outer 1-2 mm of epoxy is trimmed from newly created sections at JSC. If conductive tapes (copper, carbon, etc.) are used on the section during analysis, great care must be taken in removing the tape so that the epoxy is not pulled up with it. If in doubt, the tape can be left on the section when it is returned to JSC. Before we perform any repairs to sample sections, carbon, gold, or other coatings are removed. We accomplish this using a slurry of 0.05 micron alumina and 190 proof ethyl alcohol applied to a felt polishing pad fitted to a rotating lap wheel. Coatings are re-moved in this manner from all sections that are re-turned to JSC. The extent of the delamination determines how we proceed with the section repair. If the meteorite sample area of the section is not disturbed, then we carefully remove the delaminated epoxy. This is done using a binocular microscope with a 6X zoom, cut-proof gloves, and a very sharp, single edged razor blade. We cut the delaminated epoxy with the blade angled away from the sample area and using very light pressure. The trimmed section is then cleaned in an ultrasonic bath of 200 proof ethyl alcohol for no more than 10 seconds and carefully dried using a lint-free clean room wipe. The section is then placed into a lab oven at 110o F in preparation for epoxy. We mix the resin and hardener components of the low viscosity epoxy and very small amounts are applied to the cut edges of the section using a needle probe and the binocular microscope. Warming the epoxy helps secure the existing section by filling any voids between the glass slide and the section. After the new epoxy cures, we give the section a light polish on a lap wheel fitted with cotton polishing paper that is charged with 1 micron diamond paste. If the section has delaminated to the point of sample area being lifted from the glass, then it may be irreparable. We employ the above technique along with clamping the section in a Teflon pad arrangement in order to flatten the sample while the epoxy cures. Otherwise, the sample will tend to curl. This works to some degree, but once the sample area curls, it seldom re-turns to the original flatness without cracking or bending. Canada Balsam and Crystalbond: We repair damaged sections that had originally been prepared using Canada Balsam or Crystalbond adhesives through the gradual application of heat. We take great care with these samples since these bonding materials tend to get brittle with age. The section is heated in gradual steps (40-50o F per hour) to the melting point of the adhesive. We repair the sample while the adhesive is fluid and then the section is cooled in the same gradual manner in which it was heated. Slide Cracks and Breaks: Accidents happen. Especially with something as small and fragile as a thin/thick section. We all know someone who has driven a microscope objective into a section. As bad as the damage may look, the section can be repaired in most instances. NOTE: Please do not try to tape or glue section pieces back together prior to returning the dam-aged section. This practice usually renders the section irreparable. If the glass slide is cracked but the section is still in one piece, we repair it by infilling the crack with the low viscosity epoxy mentioned earlier. If the slide is in pieces, we can reassemble it with epoxy on a new backer slide. This is a tricky task as the pieces need to be in the correct plane with respect to each other, especially if the sample area is split among several pieces.

Meteorite↗

Bearing Anomaly for the Sentinel 6 Supplemental Calibration System

The Supplemental Calibration System (SCS) was designed to rotate an elliptical reflector for the Sentinel 6 Advanced Microwave Radiometer (AMR). By rotating the reflector, the system can perform calibrations by comparing the reflection from space to the reflection from an onboard calibration target. During the qualification testing of the SCS, a flaw was discovered that resulted in apparent brinelling of bearings that support the rotating reflector. An extensive investigation ensued to determine the root cause of the problem. Though the most likely root causes of the presumed brinelling ended up being the result of undersized bearing clamp rings and thermal mismatch, there were requirements that drove these design choices. This paper describes the design of the bearing assembly, requirements that drove the design, and documents a challenging investigation filled with ambiguous test results.

Paulsen, Gale↗

Bearing Anomaly for the Sentinel 6 Supplemental Calibration System

The Supplemental Calibration System (SCS) was designed to rotate an elliptical reflector for the Sentinel 6 Advanced Microwave Radiometer (AMR). By rotating the reflector, the system can perform calibrations by comparing the reflection from space to the reflection from an onboard calibration target. During the qualification testing of the SCS, a flaw was discovered that resulted in apparent brinelling of bearings that support the rotating reflector. An extensive investigation ensued to determine the root cause of the problem. Though the most likely root causes of the presumed brinelling ended up being the result of undersized bearing clamp rings and thermal mismatch, there were requirements that drove these design choices. This paper describes the design of the bearing assembly, requirements that drove the design, and documents a challenging investigation filled with ambiguous test results.

Paulsen, Gale↗

Use of Diffusion Bonded Cu Strap and Integrated MLI for Thermal Control of 100 K IR Detector on L’Ralph Instrument

Passive cooling of cryogenic instruments is one of the most challenging aspects of spaceflight thermal control systems. They are highly sensitive to parasitic heat leaks from their warmer environment, especially the spacecraft components. The L’Ralph instrument on the Lucy mission is an example of such a system, with its LEISA detector requiring passive cooling to temperatures below 112 K. MLI performance can be measured in terms of estar, and analysts apply bias between a high and low estar value. This approach works well for conventional MLI at room temperature, however, it can be dangerous when a mission goes through a wide range of temperatures during its lifetime, with estar values increasing exponentially as temperatures get colder. Various estar correlations are presented as well as how L’Ralph is approaching the MLI problem with the use of IMLI. IMLI uses discrete spacers to isolate each layer, and doesn’t require intermediate layers such as dacron netting. This results in estar performance that can be more precisely estimated, and yields valuesaround 0.004 at the 112K operating temperature. L’Ralph is using IMLI on the backside of the radiator, which permits a more effective use of increased radiator area, by minimizing the area dependent heat leak impact from the instrument backloading. The detector is thermally coupled to the radiator via a diffusion bonded Cu strap. The diffusion bonding process chemically bonds the Cu foil ends in order to maximize heat transfer effectiveness across the multiple foils used. Employing a pressure compensation design via the use of Ti blocks and a clamp at the strap ends ensures that as temperatures go colder, pre-load is maintained in order to minimize resistance at the strap ends. The use of both of these technologies, and how they work together are crucial to the success of the L’Ralph thermal control system.

Thermal↗