Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calculation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Dose Calculation on KV Cone Beam CT Images: An Investigation of the Hu-Density Conversion Stability and Dose Accuracy Using the Site-Specific Calibration

Precise calibration of Hounsfield units (HU) to electron density (HU-density) is essential to dose calculation. On-board kV cone beam computed tomography (CBCT) imaging is used predominantly for patients' positioning, but will potentially be used for dose calculation. The impacts of varying 3 imaging parameters (mAs, source-imager distance [SID], and cone angle) and phantom size on the HU number accuracy and HU-density calibrations for CBCT imaging were studied. We proposed a site-specific calibration method to achieve higher accuracy in CBCT image-based dose calculation. Three configurations of the Computerized Imaging Reference Systems (CIRS) water equivalent electron density phantom were used to simulate sites including head, lungs, and lower body (abdomen/pelvis). The planning computed tomography (CT) scan was used as the baseline for comparisons. CBCT scans of these phantom configurations were performed using Varian Trilogy{sup TM} system in a precalibrated mode with fixed tube voltage (125 kVp), but varied mAs, SID, and cone angle. An HU-density curve was generated and evaluated for each set of scan parameters. Three HU-density tables generated using different phantom configurations with the same imaging parameter settings were selected for dose calculation on CBCT images for an accuracy comparison. Changing mAs or SID had small impact on HU numbers. For adipose tissue, the HU discrepancy from the baseline was 20 HU in a small phantom, but 5 times lager in a large phantom. Yet, reducing the cone angle significantly decreases the HU discrepancy. The HU-density table was also affected accordingly. By performing dose comparison between CT and CBCT image-based plans, results showed that using the site-specific HU-density tables to calibrate CBCT images of different sites improves the dose accuracy to {approx}2%. Our phantom study showed that CBCT imaging can be a feasible option for dose computation in adaptive radiotherapy approach if the site-specific calibration is applied.

61 RADIATION PROTECTION AND DOSIMETRY↗

Determination of peripheral underdosage at the lung-tumor interface using Monte Carlo radiation transport calculations

Prediction of dose distributions in close proximity to interfaces is difficult. In the context of radiotherapy of lung tumors, this may affect the minimum dose received by lesions and is particularly important when prescribing dose to covering isodoses. The objective of this work is to quantify underdosage in key regions around a hypothetical target using Monte Carlo dose calculation methods, and to develop a factor for clinical estimation of such underdosage. A systematic set of calculations are undertaken using 2 Monte Carlo radiation transport codes (EGSnrc and GEANT4). Discrepancies in dose are determined for a number of parameters, including beam energy, tumor size, field size, and distance from chest wall. Calculations were performed for 1-mm{sup 3} regions at proximal, distal, and lateral aspects of a spherical tumor, determined for a 6-MV and a 15-MV photon beam. The simulations indicate regions of tumor underdose at the tumor-lung interface. Results are presented as ratios of the dose at key peripheral regions to the dose at the center of the tumor, a point at which the treatment planning system (TPS) predicts the dose more reliably. Comparison with TPS data (pencil-beam convolution) indicates such underdosage would not have been predicted accurately in the clinic. We define a dose reduction factor (DRF) as the average of the dose in the periphery in the 6 cardinal directions divided by the central dose in the target, the mean of which is 0.97 and 0.95 for a 6-MV and 15-MV beam, respectively. The DRF can assist clinicians in the estimation of the magnitude of potential discrepancies between prescribed and delivered dose distributions as a function of tumor size and location. Calculation for a systematic set of 'generic' tumors allows application to many classes of patient case, and is particularly useful for interpreting clinical trial data.

61 RADIATION PROTECTION AND DOSIMETRY↗

An analytical method to calculate equivalent fields to irregular symmetric and asymmetric photon fields

Equivalent field is frequently used for central axis depth-dose calculations of rectangular- and irregular-shaped photon beams. As most of the proposed models to calculate the equivalent square field are dosimetry based, a simple physical-based method to calculate the equivalent square field size was used as the basis of this study. The table of the sides of the equivalent square or rectangular fields was constructed and then compared with the well-known tables by BJR and Venselaar, et al. with the average relative error percentage of 2.5 ± 2.5% and 1.5 ± 1.5%, respectively. To evaluate the accuracy of this method, the percentage depth doses (PDDs) were measured for some special irregular symmetric and asymmetric treatment fields and their equivalent squares for Siemens Primus Plus linear accelerator for both energies, 6 and 18 MV. The mean relative differences of PDDs measurement for these fields and their equivalent square was approximately 1% or less. As a result, this method can be employed to calculate equivalent field not only for rectangular fields but also for any irregular symmetric or asymmetric field.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of deformed image-based dose calculations for adaptive radiotherapy of nasopharyngeal carcinoma

The ultimate goal of adaptive radiotherapy (ART) is to deliver truly customized radiation treatments. Currently, the quality of cone-beam computed tomography (CBCT) images is still inferior to that of conventional CT images in contour delineations and dose calculations for replanning purposes. This retrospective study aims to evaluate the dosimetric accuracy of using deformed conventional CT images for dose calculations, in the hope of inferring the feasibility of ART using planning CT (PCT) images that deformed to up-to-date CBCT images for patients with nasopharyngeal carcinoma (NPC). Thirty consecutive patients with NPC who had undergone 1 replan in their radiotherapy treatments were selected. The pretreatment PCT images were deformed to match the mid-treatment PCT images by deformable image registration. The same volumetric modulated arc therapy plan was then calculated on the deformed PCT images. The resulting dose distributions and dose volume histograms of the tumors and organs at risk (OARs) were compared with the original plan. Five dose levels, D{sub 98%}, D{sub 95%}, D{sub 50%}, D{sub 5%}, and D{sub 2%}, were recorded for 9 NPC targets. Four dose levels, D{sub max}, D{sub 10%}, D{sub 50%}, and D{sub mean}, were recorded for 15 OARs. The greatest percentage difference in observed dose for D{sub 98%}, D{sub 95%}, D{sub 50%}, D{sub 5%}, and D{sub 2%} of the targets were 1.71%, 1.55%, 0.64%, 0.97%, and 1.13%, respectively. The greatest percentage difference in observed dose for D{sub max}, D{sub 10%}, D{sub 50%}, and D{sub mean} of the OARs were -26.51% (left optic nerve), -17.06% (left optic nerve), 56.70% (spinal cord), and 18.97% (spinal cord), respectively. In addition, 29 of 45 (64%) dosimetric end points of the targets showed statistically significant dose differences (p p < 0.05). Dose calculations using deformed PCT images could result in significant dose uncertainties in target volumes and OARs. Larger dose deviations were found in OARs in comparison with target volumes. The spinal cord and optic nerve showed the greatest percentage dose differences and the clinical significance has yet to be determined. Deformable registration error was believed to be the problem causing the dose deviations. Owing to unknown clinical significanceof dose deviation results obtained from this study, a conventional CT scan is still required for replanning in patients with NPC who are experiencing significant anatomical changes during the course of radiation treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A modified formula for dose calculations of stereotactic ablative body radiotherapy for non–small cell lung cancer

To provide a modified formula consistent with the Monte Carlo (MC) algorithm for dose calculations during stereotactic ablative body radiotherapy for non–small cell lung cancer. Seventy CyberKnife treatment plans were calculated and analyzed by MC and ray-tracing (RT) algorithms, separately. Parameters of treatment plans were compared, and those associated with differences of dose distributions were analyzed to establish a modified formula. Gross tumor volume and tumor tracking volume (TTV) were defined as the evident disease on the sequences of the window width and level of the lung and the mediastinum. Additionally, the formula was validated by another 20 plans. The prescription dose of the 90 patients was 60 Gy/5f. The RT algorithm overestimated the planning target volume (PTV) D{sub 95} by an average of 8.59 Gy and the gross tumor volume D{sub 99} by an average of 5.84 Gy. The homogeneity index of PTV was underestimated by 0.11 on average, whereas the conformity index and new conformity index was underestimated by 0.05. The RT algorithm overestimated the dose distribution to the spinal cord by 2.23 Gy, the esophagus by 1.96 Gy, the trachea by 1.89 Gy, the left-sided bronchus by 1.77 Gy, the right-sided bronchus by 1.64 Gy, and the heart by 2.16 Gy. The average whole-lung dose volumes of lung tissues and dose volumes of V{sub 5} were overestimated by 2.69 Gy and 7.52%, respectively. A power function distribution (R{sup 2} = 0.8626) was confirmed between PTV D{sub 95} and TTV volumes. PTV D{sub 95} calculated by the MC algorithm could be computed easily with TTV and PTV D{sub 95} calculated by the RT algorithm based on the formula. The modified equation was more consistent with MC algorithm than with other formula, which could be a reference to those not accessible to the MC algorithm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Energy and mechanical properties predictions in Fe-Ni binary system by ab initio calculations

Here, the fcc random solid solutions in Fe-Ni binary system were investigated using ab initio calculations. Density functional theory (DFT) was applied along with supercells generated by the Special Quasi-Random Structure (SQS) method to predict the enthalpy of mixing and magnetic and elastic properties. The results were compared with relevant experimental and computational data produced by other groups. The effect of SQS supercell size and relaxation procedure on the predicted properties of the alloys were also studied. Our calculations show that 16-atoms SQS model provides adequate approach to the mixing energy of the alloy. However, calculation of mechanical properties requires larger supercell. Excellent agreement between experimental and calculated elastic properties was found in fcc region of Fe-Ni system.

36 MATERIALS SCIENCE↗

A New Green's Function for the Wake Potential Calculation of the SLAC S-band Constant Gradient Accelerating Section

The behavior of the longitudinal wake fields excited by a very short bunch in the SLAC S-band constant gradient accelerating structures has been studied. Wake potential calculations were performed for a bunch length of 10 microns using the author's code to obtain a numerical solution of Maxwell's equations in the time domain. We have calculated six accelerating sections in the series (60-ft) to find the stationary solution. While analyzing the computational results we have found a new formula for the Green's function. Wake potentials, which are calculated using this Green's function are in amazingly good agreement with numerical results over a wide range of bunch lengths. The Green's function simplifies the wake potential calculations and can be easily incorporated into the tracking codes. This is very useful for beam dynamics studies of the linear accelerators of LCLS and FACET.

43 PARTICLE ACCELERATORS↗

The calculation of light element impurity (α, n) yield curves in a PuO 2 matrix and associated specific yield coefficients: Influence of the reaction cross sections

Most of the Pu separated from irradiated commercial nuclear fuel is stored as PuO 2 . The primary quantitative nondestructive measurement technique used to verify the amount of Pu in storage containers is passive neutron correlation counting. An important physical property of the oxide material is the ratio, α, of the rate of (α, n) neutrons produced inside the item to the rate of neutrons produced by spontaneous fission. This ratio influences the precision of the correlated counting method and affects the interpretation of the data because of how it changes both the primary total neutron production rate and the rate of induced fission events taking place inside the item. In addition to the main O(α, n) contribution, additional contributions come from α-particle interactions with light element impurities that are inevitably present. In this work, we calculate specific (α, n) yield coefficients, expressed in units of neutrons per second per gram of α-emitting nuclide per part per million by mass of the specified impurity element distributed in a pure PuO 2 matrix, for some key α-emitting actinides commonly present in reprocessed Pu ( 238–242 Pu+ 241 Am). These coefficients are directly applicable to nuclear safeguards verification work in which the α ratio is often calculated from the Pu-isotopic composition and chemical information obtained by other means. Further, they also provide a convenient up-to-date reference set against which values generated by other methods can be compared. Results are presented for impurities with atomic number from 3 to 17 inclusive, plus K and Fe. In most cases, these coefficients are not expected to change by more than 5%–10% at any time in the future. However, as new data become available, changes as large as 20% may be needed for some targets (e.g., F). The present yield calculations are limited by the general shortage of quality experimental total (α, n) reaction cross section data, which, together with unexplained variation between determinations, means that an objective and coherent evaluation is not possible. The situation is even less satisfactory for the partial differential cross section needed to calculate neutron spectra.

(𝛼, n) reactions↗

Parallel accelerated vector similarity calculations for genomics applications

The surge in availability of genomic data holds promise for enabling determination of genetic causes of observed individual traits, with applications to problems such as discovery of the genetic roots of phenotypes, be they molecular phenotypes such as gene expression or metabolite concentrations, or complex phenotypes such as diseases. However, the growing sizes of these datasets and the quadratic, cubic or higher scaling characteristics of the relevant algorithms pose a serious computational challenge necessitating use of leadership scale computing. In this study we describe a new approach to performing vector similarity metrics calculations, suitable for parallel systems equipped with graphics processing units (GPUs) or Intel Xeon Phi processors. Our primary focus is the Proportional Similarity metric applied to Genome Wide Association Studies (GWAS) and Phenome Wide Association Studies (PheWAS). We describe the implementation of the algorithms on accelerated processors, methods used for eliminating redundant calculations due to symmetries, and techniques for efficient mapping of the calculations to many-node parallel systems. Finally, results are presented demonstrating high per-node performance and parallel scalability with rates of more than five quadrillion (5 × 10 15 ) elementwise comparisons achieved per second on the ORNL Titan system. In a companion paper we describe corresponding techniques applied to calculations of the Custom Correlation Coefficient for comparative genomics applications.

59 BASIC BIOLOGICAL SCIENCES↗

Parallel accelerated Custom Correlation Coefficient calculations for genomics applications

The massive quantities of genomic data being made available through gene sequencing techniques are enabling breakthroughs in genomic science in many areas such as medical advances in the diagnosis and treatment of diseases. Analyzing this data, however, is a computational challenge insofar as the computational costs of the relevant algorithms can grow with quadratic, cubic or higher complexity—leading to the need for leadership scale computing. In this paper we describe a new approach to calculations of the Custom Correlation Coefficient (CCC) between Single Nucleotide Polymorphisms (SNPs) across a population, suitable for parallel systems equipped with graphics processing units (GPUs) or Intel Xeon Phi processors. We describe the mapping of the algorithms to accelerated processors, techniques used for eliminating redundant calculations due to symmetries, and strategies for efficient mapping of the calculations to many-node parallel systems. Results are presented demonstrating high per-node performance and near-ideal parallel scalability with rates of more than nine quadrillion (9 × 10 15 ) elementwise comparisons achieved per second with the latest optimized code on the ORNL Titan system, this being orders of magnitude faster than rates achieved using other codes and platforms as reported in the literature. Also it is estimated that as many as 90 quadrillion (90 × 10 15 ) comparisons per second may be achievable on the upcoming ORNL Summit system, an additional 10X performance increase. Finally, in a companion paper we describe corresponding techniques applied to calculations of the Proportional Similarity metric for comparative genomics applications.

97 MATHEMATICS AND COMPUTING↗

Optimization of processor allocation for domain decomposed Monte Carlo calculations

Load imbalance plagues domain decomposed Monte Carlo calculations when sources are not uniform. Parallel efficiency for domain decomposed Monte Carlo transport calculations improves through a nonuniform allocation of processors over subdomains. In this work, we optimize the allocation with runtime diagnostics collected during a calibration step, then complete the full calculation. The diagnostic-based approach is compared to implicit filtering, an optimization algorithm for bound constrained noisy optimization problems. Finally, we consider both forward and hybrid radiation transport calculations to measure performance.

97 MATHEMATICS AND COMPUTING↗

Direct ab initio calculation of the 4 He nuclear electric dipole polarizability

The calculation of nuclear electromagnetic sum rules by directly diagonalizing the nuclear Hamiltonian in a large basis is numerically challenging and has not been performed for A>2 nuclei. With the significant progress of high performance computing, we show that calculating sum rules using numerous discretized continuum states obtained by directly diagonalizing the ab initio no-core shell model Hamiltonian is achievable numerically. Specifically, we calculate the 4 He electric dipole (E1) polarizability, that is an inverse energy weighted sum rule, employing the Daejeon16 NN interaction. We demonstrate that the calculations are numerically tractable as the dimension of the basis increases and are convergent. Our results for the 4 He electric dipole polarizability are consistent with the most recent experimental data and are compared with those of other theoretical studies employing different techniques and various interactions.

Astronomy & Astrophysics↗

Validation of the single-event method for low-energy electron transport via stopping power calculations with $\mathrm{MCNP}$

Monte Carlo simulations of low-energy ( <50 keV) electron transport in matter are essential for a broad range of application fields. Several Monte Carlo codes have developed specialized treatments for this case, but a comprehensive validation of low-energy electron transport for general-purpose simulations remains lacking in the literature. One approach to accomplish this validation is calculation of stopping power using low-energy electron transport physics, as stopping power is a fundamental radiation transport quantity which must be simulated accurately for nearly any application. Here in this work, we use the Monte Carlo N-Particle (MCNP) radiation transport code with the single-event method for electron transport to calculate stopping powers of low-energy electrons (50 eV to 30 keV) in 41 elemental solids, 14 compound solids, and five rare gas solids, comparing simulation results to published semi-empirical stopping power calculations from optical measurements. In general, the simulations give good agreement (typically within ±10%) with semi-empirical stopping power values at higher energies: 300 eV and above for most elemental solids, 1 keV and above for compound solids, and 400 eV and above for rare gas solids. Agreement between MCNP and semi-empirical values is worse below these energies. The most significant source of error is the EPRDATA14 cross section data, which does not account for changes in electronic structure due to solid-state bonding, particularly in compound materials. The simplistic model of atomic excitation used to generate the EPRDATA14 cross sections is another key source of error. Additionally, the breakdown of the continuous slowing-down approximation introduces significant uncertainty at low energies, although this is a limitation of the calculation method and not of the simulation procedure. Accounting for these and other uncertainty sources, the single event method in MCNP is robust and able to give good accuracy for a variety of low-energy electron transport problems through diverse kinds of materials.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A framework and calculator for evaluating the impacts of shelf life extension and other food loss and waste reduction technologies

Optimization of the food supply chain (FSC) depends on reducing food waste, especially at the consumer stage, where a substantial portion of food is not eaten, but instead disposed of via landfill, incineration, or in-sink disposals. One key strategy is to increase the time that consumers have before food goes bad or expires. This study developed a framework to assess the efficacy of shelf-life extension (SLE) technologies for mitigating food loss and waste (FLW), such as packaging improvements. The impact flows through the entire FSC, reducing FLW, energy use, and other inputs at each stage. The framework and resulting calculator can be used to evaluate the impact of FLW reduction at any stage for any food commodity. As shown by two SLE cases, the calculator is valuable for policy-makers, government entities, and professionals, specifically those in marketing, business development, and capital projects teams, to comprehensively evaluate the impacts of FLW reduction technologies and practices. The framework and calculator are sensitive to the shape of the consumption curve, the fraction of inedible waste, and the current shelf life. The calculator was used to assess the impacts of the United States goal of reducing food waste by consumers through various SLE lengths. It was found that uptake of several near-ready-to-deploy SLE technologies would reduce annual food production demand by about 10–19 MMT and supply chain energy consumption by 240–410 PJ in the United States.

Food loss and waste (FLW)↗

Effects of sulfur on lead partitioning during sludge incineration based on experiments and thermodynamic calculations

Highlights: • A thermodynamic equilibrium calculation was carried out. • Effects of three types of sulfurs on Pb distribution were investigated. • The mechanism for three types of sulfurs acting on Pb partitioning were proposed. • Lead partitioning and species in bottom ash and fly ash were identified. - Abstract: Experiments in a tubular furnace reactor and thermodynamic equilibrium calculations were conducted to investigate the impact of sulfur compounds on the migration of lead (Pb) during sludge incineration. Representative samples of typical sludge with and without the addition of sulfur compounds were combusted at 850 °C, and the partitioning of Pb in the solid phase (bottom ash) and gas phase (fly ash and flue gas) was quantified. The results indicate that three types of sulfur compounds (S, Na{sub 2}S and Na{sub 2}SO{sub 4}) added to the sludge could facilitate the volatilization of Pb in the gas phase (fly ash and flue gas) into metal sulfates displacing its sulfides and some of its oxides. The effect of promoting Pb volatilization by adding Na{sub 2}SO{sub 4} and Na{sub 2}S was superior to that of the addition of S. In bottom ash, different metallic sulfides were found in the forms of lead sulfide, aluminosilicate minerals, and polymetallic-sulfides, which were minimally volatilized. The chemical equilibrium calculations indicated that sulfur stabilizes Pb in the form of PbSO{sub 4}(s) at low temperatures (<1000 K). The equilibrium calculation prediction also suggested that SiO{sub 2}, CaO, TiO{sub 2}, and Al{sub 2}O{sub 3} containing materials function as condensed phase solids in the temperature range of 800–1100 K as sorbents to stabilize Pb. However, in the presence of sulfur or chlorine or the co-existence of sulfur and chlorine, these sorbents were inactive. The effect of sulfur on Pb partitioning in the sludge incineration process mainly depended on the gas phase reaction, the surface reaction, the volatilization of products, and the concentration of Si, Ca and Al-containing compounds in the sludge. These findings provide useful information for understanding the partitioning behavior of Pb, facilitating the development of strategies to control the volatilization of Pb during sludge incineration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantum Chemistry Calculations for Metabolomics

A primary goal of metabolomics and exposomics studies is to fully characterize the small molecule composition of complex biological and environmental samples. However, despite advances in analytical technologies over the past two decades, the majority of small molecules in complex samples are not readily identifiable due to the immense structural and chemical diversi-ty present within the metabolome and exposome. Current gold-standard identification methods rely on reference libraries built using authentic chemical materials (“standards”), which are not available for most molecules. Computational quantum chemis-try methods, which can be used to calculate chemical properties that are then measured by analytical platforms, offer an alter-native route for building reference libraries, i.e., in silico libraries for “standards-free” identification. In this review, we cover the major roadblocks currently facing metabolomics and discuss applications where quantum chemistry calculations offer a solu-tion. Several successful examples for nuclear magnetic resonance spectroscopy, ion mobility spectrometry, infrared spectros-copy, and mass spectrometry methods are reviewed. Finally, we consider current best practices, sources of error, and provide an outlook for quantum chemistry calculations in metabolomics and exposomics studies. We expect this review will inspire researchers in the field of small molecule identification to accelerate adoption of in silico methods for generation of reference libraries and to add quantum chemistry calculations as another tool at their disposal to characterize complex samples.

Metabolism↗

Calculation of the Thermal Neutron Scattering Cross-Section of Solids Using OCLIMAX

The thermal neutron scattering cross-section of a solid depends on the energy (or wavelength) of the incident neutrons. Devising a method to calculate the energy dependence from first principles, without the approximations built in the scattering theory, has been a major undertaking in nuclear engineering. Here, we demonstrate such a calculation method using the program OCLIMAX. In this work, our approach eliminates various approximations and limitations involved in a regular calculation with the LEAPR module of NJOY code, and the results are compared with available experimental and theoretical data. It is also demonstrated how additional insight can be obtained from the calculated full dynamical structure factor. The results reported here show the great potential and excellent platform provided by OCLIMAX for future development in the study of neutron thermalization in solid materials for different applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CHARMM-GUI Free Energy Calculator for Absolute and Relative Ligand Solvation and Binding Free Energy Simulations

Alchemical free energy simulations have long been utilized to predict free energy changes for binding affinity and solubility of small molecules. However, while the theoretical foundation of these methods is well established, seamlessly handling many of the practical aspects regarding the preparation of the different thermodynamic end states of complex molecular systems and the numerous processing scripts often remains a burden for successful applications. Here, we present CHARMM-GUI Free Energy Calculator (http://www.charmm-gui.org/input/fec) that provides various alchemical free energy perturbation molecular dynamics (FEP/MD) systems with input and post-processing scripts for NAMD and GENESIS. Four submodules are available: Absolute Ligand Binder (for absolute ligand binding FEP/MD), Relative Ligand Binder (for relative ligand binding FEP/MD), Absolute Ligand Solvator (for absolute ligand solvation FEP/MD), and Relative Ligand Solvator (for relative ligand solvation FEP/MD). Each module is designed to build multiple systems of a set of selected ligands at once for high-throughput FEP/MD simulations. The capability of Free Energy Calculator is illustrated by absolute and relative solvation FEP/MD of a set of ligands and absolute and relative binding FEP/MD of a set of ligands for T4-lysozyme in solution and the adenosine A 2A receptor in a membrane. The calculated free energy values are overall consistent with the experimental and published free energy results (within ~1 kcal/mol). We hope that Free Energy Calculator is useful to carry out high-throughput FEP/MD simulations in the field of biomolecular sciences and drug discovery.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗