Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Hybrid fs/ps CARS for Sooting and Particle-laden Flames [PowerPoint]

We report the application of ultrafast rotational coherent anti-Stokes Raman scattering (CARS) for temperature and relative oxygen concentration measurements in the plume emanating from a burning aluminized ammonium perchlorate propellant strand. Combustion of these metal-based propellants is a particularly hostile environment for laserbased diagnostics, with intense background luminosity, scattering and beam obstruction from hot metal particles that can be as large as several hundred microns in diameter. CARS spectra that were previously obtained using nanosecond pulsed lasers in an aluminumparticle- seeded flame are examined and are determined to be severely impacted by nonresonant background, presumably as a result of the plasma formed by particulateenhanced laser-induced breakdown. Introduction of fs/ps laser pulses enables CARS detection at reduced pulse energies, decreasing the likelihood of breakdown, while simultaneously providing time-gated elimination of any nonresonant background interference. Temperature probability densities and temperature/oxygen correlations were constructed from ensembles of several thousand single-laser-shot measurements from the fs/ps rotational CARS measurement volume positioned within 3 mm or less of the burning propellant surface. Preliminary results in canonical flames are presented using a hybrid fs/ps vibrational CARS system to demonstrate our progress towards acquiring vibrational CARS measurements for more accurate temperatures in the very high temperature propellant burns.

47 OTHER INSTRUMENTATION↗

Ion Stopping Powers and CT Numbers

One of the advantages of ion beam therapy is the steep dose gradient produced near the ion's range. Use of this advantage makes knowledge of the stopping powers for all materials through which the beam passes critical. Most treatment planning systems calculate dose distributions using depth dose data measured in water and an algorithm that converts the kilovoltage X-ray computed tomography (CT) number of a given material to its linear stopping power relative to water. Some materials present in kilovoltage scans of patients and simulation phantoms do not lie on the standard tissue conversion curve. The relative linear stopping powers (RLSPs) of 21 different tissue substitutes and positioning, registration, immobilization, and beamline materials were measured in beams of protons accelerated to energies of 155, 200, and 250 MeV; carbon ions accelerated to 290 MeV/n; and iron ions accelerated to 970 MeV/n. These same materials were scanned with both kilovoltage and megavoltage CT scanners to obtain their CT numbers. Measured RLSPs and CT numbers were compared with calculated and/or literature values. Relationships of RLSPs to physical densities, electronic densities, kilovoltage CT numbers, megavoltage CT numbers, and water equivalence values converted by a treatment planning system are given. Usage of CT numbers and substitution of measured values into treatment plans to provide accurate patient and phantom simulations are discussed.

07 ISOTOPE AND RADIATION SOURCES↗

The Imaging and Coherence Beamline I13 at Diamond

The coherence and imaging beamline I13 is dedicated to hard x-ray imaging on the micro- and nano-lengthscale, performing microscopy either in direct or reciprocal space. For both, lens-based and lensless imaging, two independent stations will be operated in a separate building at a distance of 250 m from the source. The imaging branch will perform in-line phase contrast imaging and tomography over a large field of view in the 6- to 35-keV energy range. In addition, it will be possible to switch to full-field microscopy with 50-nm spatial resolution. Other microscopies will be developed according to the scientific needs. Resolution beyond the limitations given by the detector and x-ray optics will be achieved with techniques working in the far field. Coherent x-ray diffraction (CXRD) and other coherent diffraction imaging techniques such as ptychography will also be implemented on the same 'coherence' branch. The beamline hosts a number of innovative features such as the so-called 'mini-beta' layout for electron optics in the storage ring or new concepts for beamline instrumentation. The stations will be operational in 2011.

43 PARTICLE ACCELERATORS↗

The influence of the ionizer geometry on the absolute density calibration of reactive neutral species in a molecular beam mass spectrometry

Molecular beam mass spectrometry is a powerful diagnostic technique, which can be used for the measurement of absolute number densities of reactive species in non-equilibrium reactive plasmas. However, the calibration of absolute number densities is susceptible to systematic errors. Critical issues are the proper design of the sampling system and the correction of the background signal. Here we discuss the effect of reflections of particles from the molecular beam in an ionizer, formation of additional background particle density in the ionizer, and its effect on the density calibration of reactive particle densities. A Monte Carlo simulation of particle trajectories in the ionizer is used to estimate the detection probability of a beam particle after the collision with the ionizer wall. The simulation shows that as much as two-third of the signal can be due to scattered particles in the commercially available mass spectrometers. This effect leads to systematic underestimation of densities of reactive particles, which are reactive at the surface and, therefore, do not have any background density. A simple change in the ionizer geometry is suggested, which can significantly reduce this problem.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo calculations of correction factors for plastic phantoms in clinical photon and electron beam dosimetry

The purpose of this study is to calculate correction factors for plastic water (PW) and plastic water diagnostic-therapy (PWDT) phantoms in clinical photon and electron beam dosimetry using the EGSnrc Monte Carlo code system. A water-to-plastic ionization conversion factor k{sub pl} for PW and PWDT was computed for several commonly used Farmer-type ionization chambers with different wall materials in the range of 4-18 MV photon beams. For electron beams, a depth-scaling factor c{sub pl} and a chamber-dependent fluence correction factor h{sub pl} for both phantoms were also calculated in combination with NACP-02 and Roos plane-parallel ionization chambers in the range of 4-18 MeV. The h{sub pl} values for the plane-parallel chambers were evaluated from the electron fluence correction factor {phi}{sub pl}{sup w} and wall correction factors P{sub wall,w} and P{sub wall,pl} for a combination of water or plastic materials. The calculated k{sub pl} and h{sub pl} values were verified by comparison with the measured values. A set of k{sub pl} values computed for the Farmer-type chambers was equal to unity within 0.5% for PW and PWDT in photon beams. The k{sub pl} values also agreed within their combined uncertainty with the measured data. For electron beams, the c{sub pl} values computed for PW and PWDT were from 0.998 to 1.000 and from 0.992 to 0.997, respectively, in the range of 4-18 MeV. The {phi}{sub pl}{sup w} values for PW and PWDT were from 0.998 to 1.001 and from 1.004 to 1.001, respectively, at a reference depth in the range of 4-18 MeV. The difference in P{sub wall} between water and plastic materials for the plane-parallel chambers was 0.8% at a maximum. Finally, h{sub pl} values evaluated for plastic materials were equal to unity within 0.6% for NACP-02 and Roos chambers. The h{sub pl} values also agreed within their combined uncertainty with the measured data. The absorbed dose to water from ionization chamber measurements in PW and PWDT plastic materials corresponds to that in water within 1%. Both phantoms can thus be used as a substitute for water for photon and electron dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

Mitigation Plans for the Microbunching-Instability-Related COTR at ASTA/FNAL

At the Advanced Superconducting Test Accelerator (ASTA) now under construction at Fermilab, we anticipate the appearance of the microbunching instability related to the longitudinal space charge (LSC) impedances. With a photoinjector source and up to two chicane compressors planned, the conditions should result in the shift of some microbunched features into the visible light regime. The presence of longitudinal microstructures (microbunching) in the electron beam or the leading edge spikes can result in strong, spatially localized coherent enhancements of optical transition radiation (COTR) that mask the actual beam profile. Several efforts on mitigation of the effects in the diagnostics task have been identified. At ASTA we have designed the beam profiling stations to have mitigation features based on spectral filtering, scintillator choice, and the timing of the trigger to the digital camera's CCD chip. Since the COTR is more intense in the NIR than UV we have selectable bandpass filters centered at 420 nm which also overlap the spectral emissions of the LYSO:Ce scintillators. By delaying the CCD trigger timing of the integration window by 40-50 ns, we can reject the prompt OTR signal and integrate on the delayed scintillator light predominately. This combination of options should allow mitigation of COTR enhancements of order 100-1000 in the distribution.

43 PARTICLE ACCELERATORS↗

High energy flux thermo-mechanical test of 1D-carbon-carbon fibre composite prototypes for the SPIDER diagnostic calorimeter

Operation of the thermonuclear fusion experiment ITER requires additional heating via injection of neutral beams from accelerated negative ions. In the SPIDER test facility, under construction in Padova, the production of negative ions will be studied and optimised. STRIKE (Short-Time Retractable Instrumented Kalorimeter Experiment) is a diagnostic used to characterise the SPIDER beam during short pulse operation (several seconds) to verify if the beam meets the ITER requirements about the maximum allowed beam non-uniformity (below ±10%). The major components of STRIKE are 16 1D-CFC (Carbon-Carbon Fibre Composite) tiles, observed at the rear side by a thermal camera. This contribution gives an overview of some tests under high energy particle flux, aimed at verifying the thermo-mechanical behaviour of several CFC prototype tiles. The tests were performed in the GLADIS facility at IPP (Max-Plank-Institut für Plasmaphysik), Garching. Dedicated linear and nonlinear simulations were carried out to interpret the experiments and a comparison of the experimental data with the simulation results is presented. The results of some morphological and structural studies on the material after exposure to the GLADIS beam are also given.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron beam characterization via quantum coherent electric field imaging

We demonstrate an all-optical, minimally invasive electron beam (𝑒−beam) characterization using Rydberg electrometry. An 𝑒-beam passes through a localized detector volume containing thermal Rb atoms that are optically excited in a quantum superposition of ground and Rydberg states. The 𝑒-beam's electric field perturbs atomic coherence and modifies resonance fluorescence in a narrow spectral region near the two-photon optical transition. Imaging Rb fluorescence provides a map of the electric field from the 𝑒-beam via Rydberg state Stark shifts and allows us to reconstruct the 𝑒-beam width, centroid position, and current. For an 𝑒-beam of 20 keV and electron currents of 20–40 µ⁢A, we measured the centroid position with an accuracy of ≤ 8 µ⁢m and width to within 100 µ⁢m, limited by the experimental sensitivity of electric field reconstruction of ∼0.02 V/cm. This method is suitable for a wide range of electron energies and currents, and can be adopted for nuclear and high-energy experiments for minimally invasive real-time diagnostics and profiling of charged particle beams.

Behary, Rob [College of William and Mary, Williams↗

4D beam matrix reconstruction in particle accelerators

Transverse beam parameters in particle accelerators are commonly described using the Twiss parameters, which are experimentally accessible yet inherently limited because they neglect correlations between different transverse coordinates. Such correlations frequently arise from uncompensated cathode magnetic fields or misaligned focusing quadrupoles, affecting beam quality and accelerator performance. To address this limitation, we propose and validate a novel diagnostic method for the complete four-dimensional (4D) transverse beam matrix. Our method involves passing the beam through a beamline comprising both conventional and skew quadrupole magnets, followed by downstream measurements of the resulting two-dimensional (2D) beam profiles. These measurements represent distinct 2D projections of the underlying 4D transverse phase–space distribution. By systematically varying quadrupole strengths, multiple independent projections of the beam phase space are obtained. We reconstruct the original 4D beam matrix from these measured projections using an optimization-based least-square fit, providing fast and robust reconstruction regardless of the specific beamline configuration. Through extensive numerical simulations and realistic particle-tracking studies, we demonstrate the diagnostic’s accuracy, robustness, and capability to achieve reconstruction uncertainties smaller than measurement errors, particularly when employing sufficient numbers of quadrupole scans. This method presents a powerful and flexible approach for comprehensive beam characterization and accelerator tuning.

43 PARTICLE ACCELERATORS↗

Optics of the NIFS negative ion source test stand by infrared calorimetry and numerical modelling

At National Institute for Fusion Science (NIFS), a multi-ampere negative ion source is used to support the R&D on H{sup −} production, extraction, and acceleration. In this contribution, we study the characteristics of the acceleration system of this source, in order to characterize the beam optics at different operational conditions. A dedicated experimental campaign was carried out at NIFS, using as main diagnostic the infra-red imaging of the beam profiles. The experimental measurements are also compared with 3D numerical simulations, in order to validate the codes and to assess their degree of reliability. The simulations show a satisfactory agreement with the experimental results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

National Ignition Facility 192 beam 3w power sensor

NIF requires additional laser diagnostic capabilities to support existing missions and drive performance of the laser to higher powers and energies. There exists a current gap in laser power data on the facility due to the subset of beamlines that are measurement capable. Additionally, as NIF increases the radiation yield on target experiments, the performance of the current laser diagnostic 3w power sensor system has been steadily decreasing. The degradation of the current system is not well understood and needs to be characterized to facilitate any new system design.

42 ENGINEERING↗

Development of a high-brightness and low-divergence lithium neutral beam for a Zeeman polarimetry on JT-60U

A high-brightness and low-divergence neutral beam is obtained for a Zeeman polarimetry of edge plasmas on JT-60U. The electron density and the pitch angle of the magnetic field line, thus the plasma current density distribution, can be measured by the Zeeman polarimetry using the lithium beam. A thermionic ion source heated by an electron beam is developed in order to obtain the ion beam current extraction over 10 mA. The beam optics is designed after detailed numerical simulation taking the space charge effects into account because a low-divergence angle of the neutral lithium beam leads to a narrow spectrum of the beam emission. It is also necessary to keep the beam radius small for good spatial resolution due to a long beam line of 6.5 m. The newly developed ion gun is operated on a test stand which simulates the diagnostic arrangement on JT-60U. The ion beam current of 10 mA at a beam energy of 10 keV is successfully extracted from the ion source operated at the temperature over 1300 deg. C and focused by Einzel lens. The full width at half maximum radius of the ion beam at the neutralizer is about 9 mm. A sodium vapor neutralizer neutralizes the collimated ion beam fully at the temperature of 300 deg. C. The neutral beam profiles are measured at two locations of the beam line at Z=2.3 m (beam monitor position) and Z=6.5 m (plasma region). The half-width at half maximum radius of the neutral beam of 26 mm and the equivalent beam current of 3 mA with the beam divergence angle of 0.2 deg. which is the half-angle divergence are obtained. Those parameters satisfy the requirements of the Zeeman polarimetry. Furthermore, a long pulse extraction with a current of 10 mA and duration of 50 s is attained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low temperature plasma diagnostics with tunable synchrotron vacuum ultraviolet photoionization mass spectrometry

Plasma-based technology is of great importance for a range of industrial applications. However, due to the complexity of gas-phase and surface chemical reactions, the underlying plasma chemistry is still poorly understood, leading to a growing demand for experimental setups on plasma diagnostics. In this paper, we report an apparatus that combines tunable synchrotron vacuum ultraviolet (VUV) photoionization with molecular-beam mass spectrometry for detecting ionic and neutral species formed in the processes of plasma discharge. The products including reactive intermediates such as enols can be identified unambiguously with the measurements of photoionization mass spectrometry (PIMS) and photoionization efficiency spectra. The tunable VUV PIMS has been proven as an ideal and sensitive tool for a comprehensive understanding of plasma chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimizing the front end test stand high performance H{sup -} ion source at RAL

The aim of the front end test stand project is to demonstrate that chopped low energy H{sup -} beams of high quality can be produced. The beam line currently consists of the ion source, a 3 solenoid low energy beam transport and a suite of diagnostics. A brief status report of the radio frequency quadrupole is given. This paper details the work to optimize the ion source performance. A new high power pulsed discharge power supply with greater reliability has been developed to allow long term, stable operation at 50 Hz with a 60 A, 2.2 ms discharge pulse and up to 100 A at 1.2 ms. The existing extraction power supply has been modified to operate up to 22 kV. Results from optical spectroscopy measurements and their application to source optimization are summarized. Source emittances and beam currents of 60 mA are reported.

43 PARTICLE ACCELERATORS↗

Electromagnetic-wave excitation in a large laboratory beam-plasma system

The mechanism by which unstable electrostatic waves of a beam-plasma system are converted into observed electromagnetic waves is of current interest in space physics and in tokamak fusion research. The process involved in the conversion of electrostatic to electromagnetic waves at the critical layer is well understood. However, the radiation from uniform plasmas cannot be explained on the basis of this process. In connection with certain difficulties, it has not yet been possible to establish the involved emission processes by means of experimental observations. In the considered investigation these difficulties are overcome by employing a large laboratory plasma in a parameter range suitable for detailed diagnostics. A finite-diameter electron beam is injected into a uniform quiescent afterglow plasma of dimensions large compared with electromagnetic wavelengths. The considered generation mechanism concerning the electromagnetic waves is conclusively confirmed by observing the temporal evolution of an instability

Whelan, D. A.↗

An Overview Of The Motional Stark Effect Diagnostic On DIII-D And Design Work For An ITER MSE

The advanced tokamak research program at DIII-D relies critically on the measurement of the current density profile. This was made possible by the development of a Motional Stark Effect (MSE) polarimeter that was first installed in 1992. Three major upgrades have since occurred, and improvements in our understanding of critical performance issues and calibration techniques are ongoing. In parallel with these improvements, we have drawn on our DIII-D experience to begin studies and design work for MSE on burning plasmas and ITER. This paper first reviews how Motional Stark Effect polarimetry (MSE) is used to determine the tokamak current profile. It uses the DIII-D MSE system as an example, and shows results from the latest upgrade that incorporates an array of channels from a new counter-Ip injected neutral beam. The various calibration techniques presently used are reviewed. High-leverage or unresolved issues affecting MSE performance and reliability in ITER are discussed. Next, we show a four-mirror collection optics design for the two ITER MSE views. Finally, we discuss measurements of the polarization properties of a few candidate mirrors for the ITER MSE. Work supported by the U.S. Department of Energy under W-7405-ENG-48.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Heavy ion beam probe coordinate mapping and calibration at WEGA stellarator

The heavy ion beam probe (HIBP) is an established nonperturbing diagnostic for high spatially and temporary resolved measurements of magnetically confined plasma parameters such as potential, density, and temperature. These quantities can be determined from the change in the ion beam parameters (charge, intensity, and trajectory) passing through a plasma volume due to collisions with electrons and interaction with the confining magnetic field. One of the problems that should be solved during HIBP installation and tuning is the coordinate matching. Conventionally the coordinate mapping of the HIBP measurement point is provided by ray tracing calculations of the ion beam in the magnetic field. However, it is very difficult to include all physical effects and uncertainties in the model. Thus, the result of the calculations may differ from the real probing position. In order to improve the mapping precision of the HIBP installed at the WEGA stellarator an additional measurement of the beam position is provided using a primary beam detector array inside the vacuum vessel. This allows comparing the measured and calculated ion beam positions in order to prove the calculated coordinate precision and include adjustments in the calculation code if necessary. The principle and the results of this calibration, which is not specific to WEGA but could be adapted to other experiments as well, are presented in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge Diagnostics for Laser Plasma Accelerators

The electron energy dependence of a scintillating screen (Lanex Fast) was studied with sub-nanosecond electron beams ranging from 106 MeV to 1522 MeV at the Lawrence Berkeley National Laboratory Advanced Light Source (ALS) synchrotron booster accelerator. The sensitivity of the Lanex Fast decreased by 1percent per 100 MeV increase of the energy. The linear response of the screen against the charge was verified with charge density and intensity up to 160 pC/mm2 and 0.4 pC/ps/mm2, respectively. For electron beams from the laser plasma accelerator, a comprehensive study of charge diagnostics has been performed using a Lanex screen, an integrating current transformer, and an activation based measurement. The charge measured by each diagnostic was found to be within +/-10 percent.

43 PARTICLE ACCELERATORS↗