Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “backgrounds”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Neutron diffraction probing hydrogen in monoclinic H 2 VOPO 4

Light hydrogen atoms are resolvable with neutrons; however, the massive incoherent background inhibits the diffraction quality. To improve the signal, isotope treatment by deuteration becomes a prerequisite for a successful crystallographic understanding of hydrogen-containing materials by neutron diffraction. Thanks to the low-background and high-resolution time-of-flight neutron diffractometer, this work demonstrates a direct and successful measurement of high-quality neutron diffraction patterns of H 2 VOPO 4 powders, a precursor of a high-capacity alkali-ion battery cathode. The Rietveld refinement identifies the hydrogen coordinates, occupancy, and thermal parameters in the H 2 VOPO 4 lattice. Finally, the result highlights the unique capability of neutron diffraction for the structure characterization of hydrogen-containing materials, potentially without requiring costly and possibly artifact-inducing deuteration for neutron diffraction.

36 MATERIALS SCIENCE↗

Performance testing of a Compton suppressed coincidence measurements using the Advanced Radionuclide Gamma-spectrOmeter

A Compton-suppressed multidimensional gamma-spectrometer is being developed within the Shallow Underground Laboratory (SUL) at Pacific Northwest National Laboratory (PNNL, USA). This Advanced Radionuclide Gamma-spectrOmeter (ARGO) system consists of two Broad Energy Germanium (BEGe) detectors, surrounded by a 12-detector sodium iodide (NaI) Compton suppression shield, situated inside a low-background lead and copper shield, fitted with a cosmic veto background reduction system. The detector has advanced functionality, including operation in single or combined detector mode, coincidence mode and Compton suppressed coincidence mode. Validation experiments measuring a neutron irradiated natural uranium sample, have demonstrated order of magnitude improvements in gamma detection sensitivity compared to conventional gamma-spectrometry techniques. Importantly this research demonstrates the feasibility of processing and analysing high-multiplicity datasets and the potential for high-sensitivity radionuclide measurements.

ARGO↗

A holistic approach to the optimization of neutron beam transport at the LANSCE facility

An advanced neutron beam collimation system has been developed as part of an effort to optimize neutron beam transport at the Weapons Neutron Research (WNR) Facility, located within the Los Alamos Neutron Science Center (LANSCE). The goal of this work was to develop and demonstrate techniques to tailor neutron delivery in order to provide maximum available flux on sample with a specific beam profile, while simultaneously reducing unwanted background. A holistic approach was taken, upgrading the facility spallation target, facility metrology infrastructure, and flight path shutter insert to support the implementation of this advanced collimation system. Here, modern instruments and software were employed to conduct facility surveys, characterization of as-built geometry of critical components, 3D ray tracing and neutron transport calculations. Beam images and flux measurements were acquired after installation to evaluate the performance of the collimation system and to demonstrate consistent agreement with MCNP simulations which showed an 87% increase of flux on sample while providing suppression of background neutron impingement on the sample frame by 10 3 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Clinical 6 MV X-Ray Facility Photo-Neutron/Fission Interrogations with TMFD Sensors

Detection of several targets (U, Be, D2O) of interest to national security has been achieved at Purdue University’s 6 MV (~104 R/h) X-Ray clinical linear accelerator (CLINAC), from photoneutron/fission induced neutron signatures using a Centrifugally Tensioned Metastable Fluid Detector (CTMFD). Traditional neutron detection schemes were saturated and ineffective under the intense (to ~104 R/h) photon environment; however, the CTMFD sensor technology was capable of measuring the relatively insignificant (~10-12x lower intensity) neutron field produced from 6 MeV-end point X-Ray beam interactions with the CLINAC components and surroundings. This is in stark contrast to published results based on conventional belief for immeasurable neutron dose in 6 MV CLINAC facilities. Photoneutron and photofission neutron production rates were detected and analyzed at various standoffs from the isocenter, with and without special nuclear material (SNM) related targets ranging in mass from 5 g of Be, to ~0.6 kg of UO2. It was confirmed that 6 MV X-Ray photons do result in measurable neutron dose above normal cosmic background. Additionally, in threshold mode, the CTMFD operating under a tensioned metastable pressure of -5bar, enabled conclusive rejection of background photoneutrons, while enabling the rapid detection of: Be, D2O, C and U targets within seconds to minutes while operating in and around 104 R/h photon fields.

Ozerov, Stepan↗

A stilbene–strontium iodide based radioxenon detection system for monitoring nuclear explosions

Atmospheric measurement of noble gases has been extensively used for monitoring clandestine nuclear weapon explosions for many years. The ratios of four xenon isotopes of interest ( 131 mXe, 133 mXe, 133 Xe, and 135 Xe) help in discriminating regular reactor operations from nuclear tests. A new coincidence-based detection system using stilbene and strontium iodide [SrI 2 (Eu)] for electron and photon detection respectively was developed at Oregon State University to address some of the challenges of the radioxenon systems deployed in the field such as memory effect, and poor energy resolution. Silicon photomultipliers (SiPMs) were used for sensing optical photons from all scintillation media. Real-time coincidence identification was achieved using the eight-channel digital pulse processor. The detection system was evaluated using lab check sources and Oregon State TRIGA reactor irradiated radioxenon samples. A 48-hour background coincidence spectrum was collected yielding a coincidence count rate and background rejection rate of 0.0174 ± 0.0003 counts per second (cps) and 98.9% respectively. The minimum detectable concentration (MDC) of the system was evaluated to be 0.11 ± 0.01, 0.13 ± 0.02, 0.20 ± 0.02, and 0.73 ± 0.08 for 131 mXe, 133 mXe, 133 Xe, and 135 Xe respectively. The memory effect of the detection system was found to be 0.069 ± 0.015%, which is almost a 70-fold reduction compared to traditional plastic scintillators. Here, the detection elements, custom-designed electronics, and the detector response to radioxenon are detailed in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DGFRS-2—A gas-filled recoil separator for the Dubna Super Heavy Element Factory

The main goal of development of the new Dubna Gas-Filled Recoil Separator (DGFRS-2) is to sufficiently improve the efficiency of studies on heavy and superheavy nuclei at the Super Heavy Element Factory of the Flerov Laboratory of Nuclear Reactions (FLNR) at the Joint Institute for Nuclear Research. The use of beams with the intensity up to 6×10 13 s -1 (10 pμA) delivered by the DC280 cyclotron requires an effective setup providing high suppression of background reaction products. Additionally, the described gas-filled separator is optimized for synthesis and study of heavy isotopes produced in complete fusion reactions of massive nuclei. Basic characteristics of DGFRS-2, as well as the results of the first test experiments, are presented. In comparison to the DGFRS-1, the transmission efficiency was doubled, and the background was reduced by a factor 200.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reduction of detection limit and quantification uncertainty due to interferent by neural classification with abstention

Many measurements in the physical sciences can be cast as counting experiments, where the number of occurrences of a physical phenomenon informs the prevalence of the phenomenon's source. Often, detection of the physical phenomenon (termed signal) is difficult to distinguish from naturally occurring phenomena (termed background). In this case, the discrimination of signal events from background can be performed using classifiers, and they may range from simple, threshold-based classifiers to sophisticated neural networks. These classifiers are often trained and validated to obtain optimal accuracy, however we show that the optimal accuracy classifier does not generally coincide with a classifier that provides the lowest detection limit, nor the lowest quantification uncertainty. Here, we present a derivation of the detection limit and quantification uncertainty in the classifier-based counting experiment case. We also present a novel abstention mechanism to minimize the detection limit or quantification uncertainty a posteriori. We illustrate the method on two data sets from the physical sciences, discriminating Ar-37 and Ar-39 radioactive decay from non-radioactive events in a gas proportional counter, and discriminating neutrons from gammas in an inorganic scintillator and report results therefrom.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of a positron-emission-tomography-based SiPM readout for compact segmented neutron imagers

Gamma-ray emission from special nuclear material (SNM) is relatively easy to shield from detection using modest amounts of high-Z material. In contrast, fast-neutrons are much more penetrating and can escape relatively thick high-Z shielding without losing significant energy. Furthermore, fast neutrons provide a clear and unambiguous signature of the presence of SNM with few competing natural background sources. The challenge of detecting fast neutrons is twofold. First, the neutron flux from SNM are only a fraction of the corresponding gamma-ray flux. Second, fast neutrons can be difficult to differentiate from gamma rays. The ability to discriminate gamma rays from neutrons, combined with a neutron imaging capability, can in some situations enable the localization of SNM neutron sources distinct from background. With the developments of pulse-shape-sensitive plastic scintillators that offer excellent gamma-ray/neutron discrimination, and arrays of silicon photomultipliers combined with highly scalable and fast positron-emission-tomography (PET) multi-channel readout systems, field-deployable neutron imagers suitable for SNM detection might now be within reach. In this paper, we present a characterization of the performance of a recently available commercial PET-scanner readout, including its sensitivity to pulse-shape differences between fast neutrons and gamma rays, energy and timing resolution. Here, we find that, while the pulse-shape discrimination is achievable with stilbene, further improvement of the readout is required to achieve it with the PSD-capable available plastic scintillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of $\text{BDX-MINI}$ veto systems

Here this paper describes the veto system of the BDX-MINI detector installed at Jefferson Lab (US). The BDX-MINI experiment is the first electron beam-dump experiment specifically designed to search for Light Dark Matter (LDM) particles in the MeV-GeV mass range. The core of the BDX-MINI detector is a lead-tungstate electromagnetic calorimeter, for a total volume of 4 dm 3 . The calorimeter is surrounded by a multi-layer veto aimed at rejecting cosmic background: the innermost layer of the veto is made by a passive tungsten shielding for low energy radiation, while plastic scintillators make the middle and outer layers for charged cosmic particles rejection. Being located about 20 m downstream, the dirt between the beam dump and the detector provides sufficient shielding from the beam-related background. In 2019–2020, BDX-MINI was exposed for about six months to weakly interacting particles (neutrinos and, if existing, DM) produced by a 2.176 GeV electron beam incident on the beam dump of experimental Hall-A at Jefferson Lab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RPC based tracking system at CERN GIF++ facility

With the HL-LHC upgrade of the LHC machine, an increase of the instantaneous luminosity by a factor of five is expected and the current detection systems need to be validated for such working conditions to ensure stable data taking. At the CERN Gamma Irradiation Facility (GIF++) many muon detectors undergo such studies, but the high gamma background can pose a challenge to the muon trigger system which is exposed to many fake hits from the gamma background. A tracking system using RPCs is implemented to clean the fake hits, taking profit of the high muon efficiency of these chambers. This work will present the tracking system configuration, used detector analysis algorithm and results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Capability Demonstration of a 3D CdZnTe Detector on a High-Altitude Balloon Flight

In collaboration between the University of Michigan and Los Alamos National Laboratory, a 3D position-sensing CdZnTe (CZT) detector prototype was built and integrated into a high-altitude balloon platform to evaluate its performance in a space-like mixed-radiation environment. The detector prototype, Orion Eagle, was designed to operate in near-vacuum environments without any temperature regulation. Orion Eagle was hand-launched from NASA’s Columbia Scientific Balloon Facility (CSBF) at Fort Sumner, NM on September 26, 2021, and successfully operated throughout a 9-hour flight, which reached 38.5 km in altitude. The flight met its objectives, successfully detecting atmospheric gamma rays and galactic cosmic rays, and raising the Technical Readiness Level from 4 to 6 for large-volume 3D CZT detector technology for space applications. Ionization tracks produced by charged particles create spatial signatures in the detector that are distinguishable from discrete gamma-ray interactions. Therefore, the 3D position-sensing capabilities using pixelated electrodes on a CZT detector can help enable discrimination of background charged particles from gamma-ray events without an anticoincidence shield. The potential for background rejection capability, ambient-temperature operation, gamma-ray coded-aperture and Compton imaging, and near High Purity Germanium (HPGe) energy resolution motivate the use of large-volume 3D CZT imaging spectrometers in future space missions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hydrodynamic modeling of plasma channel systems for laser plasma accelerators

Structured plasma channels are an essential technology for driving high-gradient, plasma-based acceleration and control of electron and positron beams for advanced concepts accelerators. Laser and gas technologies can permit the generation of long plasma columns known as hydrodynamic, optically-field-ionized (HOFI) channels, which feature low on-axis densities and steep walls. By carefully selecting the background gas and laser properties, one can generate narrow, tunable plasma channels for guiding high intensity laser pulses. Here, we present on the development of simulations of HOFI channels using the FLASH code, a publicly available radiation hydrodynamics code. We explore sensitivities of the channel evolution to laser profile, intensity, and background gas conditions, and identify relevant scalings with laser intensity through a range of practical channel delays.

Accelerators↗

The MUSE Target Chamber Post Veto

The Muon Scattering Experiment (MUSE) was developed to address the proton radius puzzle through simultaneous electron–proton and muon-proton scattering using the Paul Scherrer Institute’s πM1 secondary beamline. MUSE uses a large-solid-angle, non-magnetic spectrometer to detect beam particles scattering from a liquid hydrogen cell contained within a vacuum chamber. Due to the large scattering windows, the structural integrity of the chamber is supported by posts located at small scattering angles. While out of the acceptance, particles in the tails of the beam distribution can strike these posts, causing a significant trigger background. We describe the design and performance of the Target Chamber Post Veto (TCPV) detector installed inside the vacuum chamber to remove these background events at the trigger level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling the effect of nitrogen recycling on the erosion and leakage of tungsten impurities from the SAS-VW divertor in DIII-D during nitrogen gas injection

The new SAS-VW divertor in DIII-D has tungsten-coated components to enable the study of tungsten erosion and leakage from a closed, slot-like divertor. A proposed method of actively managing the tungsten impurities is to inject low-Z impurities, such as nitrogen, into the Scrape-off-Layer (SOL) to modify the conditions in the plasma boundary and in turn manipulate both the erosion and subsequent transport of tungsten. Nitrogen injection from the SOL crown has been modeled using SOLPS-ITER to calculate the background plasma including the intrinsic carbon and the injected nitrogen impurities, and subsequently DIVIMP has been used to calculate the tungsten erosion and transport on top of the background plasma solution. This workflow has been used to model scenarios at a variety of nitrogen injection rates with different assumptions about the nitrogen recycling at the target. In the scenario modeled here, an optimal nitrogen injection rate around 3-4 x 10 20 N/s is found to reduce the amount of tungsten reaching the core by a factor of about 2.4. However, when the nitrogen recycling rate at the divertor targets is high, the nitrogen redistributes within the slot leading to increased tungsten sputtering, and the range of injection rates resulting in tungsten mitigation becomes narrower.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron capture measurements at UMass lowell research reactor

A new facility was designed around the thermal column beam port of the 1 MW Research Reactor at the University of Massachusetts Lowell. Thermal neutrons are collimated to a 1-inch diameter beam and incident on samples to induce the radiative neutron capture. New measurements of capture gamma rays are planned for Mn, Cu, Ni, Cr, and Gd samples in the next few years. The experiments will be carried out in close collaboration with the ENSDF (Evaluated Nuclear Structure Data File) evaluation group at Brookhaven National Laboratory. The gamma rays are measured using an array of high-resolution HPGe detectors. Some of the HPGe detectors use active Compton shields that were designed from scintillation detectors and improve significantly the signal-to-background in the measured gamma-ray spectra with HPGe. The experimental spectra will be validated by the GEANT4 simulations of the array and theoretical models of the emission of gamma rays from the compound nucleus. In conclusion, the new experimental results on the capture gamma ray intensities will be incorporated in future ENSDF evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Search for Wγ resonances in proton-proton collisions at √s=13 TeV using hadronic decays of Lorentz-boosted W bosons

A search for W$\gamma$ resonances in the mass range between 0.7 and 6.0 TeV is presented. The W boson is reconstructed via its hadronic decays, with the final-state products forming a single large-radius jet, owing to a high Lorentz boost of the W boson. The search is based on proton-proton collision data at $\sqrt{s} = $ 13 TeV, corresponding to an integrated luminosity of 137 fb$^{-1}$, collected with the CMS detector at the LHC in 2016-2018. The W$\gamma$ mass spectrum is parameterized with a smoothly falling background function and examined for the presence of resonance-like signals. No significant excess above the predicted background is observed. Model-specific upper limits at 95% confidence level on the product of the cross section and branching fraction to the W$\gamma$ channel are set. Limits for narrow resonances and for resonances with an intrinsic width equal to 5% of their mass, for spin-0 and spin-1 hypotheses, range between 0.17 fb at 6.0 TeV and 55 fb at 0.7 TeV. These are the most restrictive limits to date on the existence of such resonances. In specific narrow-resonance benchmark models, heavy scalar (vector) triplet resonances with masses between 0.75 (1.15) and 1.40 (1.36) TeV are excluded for a range of model parameters. Model-independent limits on the product of the cross section, signal acceptance, and branching fraction to the W$\gamma$ channel are set for minimum W$\gamma$ mass thresholds between 1.5 and 8.0 TeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for high-mass resonances decaying to a jet and a Lorentz-boosted resonance in proton-proton collisions at s = 13 TeV

A search is reported for high-mass hadronic resonances that decay to a parton and a Lorentz-boosted resonance, which in turn decays into a pair of partons. The search is based on data collected with the CMS detector at the LHC in proton-proton collisions at $\sqrt{s}$ = 13 TeV, corresponding to an integrated luminosity of 138 fb$^{-1}$. The boosted resonance is reconstructed as a single wide jet with substructure consistent with a two-body decay. The high-mass resonance is thus considered as a dijet system. The jet substructure information and the kinematic properties of cascade resonance decays are exploited to disentangle the signal from the large quantum chromodynamics multijet background. The dijet mass spectrum is analyzed for the presence of new high-mass resonances, and is found to be consistent with the standard model background predictions. Results are interpreted in a warped extra dimension model where the high-mass resonance is a Kaluza-Klein gluon, the boosted resonance is a radion, and the final state partons are all gluons. Limits on the production cross section are set as a function of the Kaluza-Klein gluon and radion masses. These limits exclude at 95% confidence level models with Kaluza-Klein gluon masses in the range from 2.0 to 4.3 TeV and radion masses in the range from 0.20 to 0.74 TeV. By exploring a novel experimental signature, the observed limits on the Kaluza-Klein gluon mass are extended by up to about 1 TeV compared to previous searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗