Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Wind Power Production”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Disturbance-Adaptive Short-Term Frequency Support of a DFIG Associated With the Variable Gain Based on the ROCOF and Rotor Speed

This paper proposes a disturbance-adaptive short-term frequency support scheme of a doubly fed induction generator (DFIG) that can improve the frequency-supporting capability while ensuring stable operation. In the proposed scheme, the output of the additional control loop is determined as the product of the frequency deviation and adaptive gain, which is modified depending on the rate of change of frequency (ROCOF) and rotor speed. To achieve these objectives, the adaptive gain is set to be high during the early stage of a disturbance, when the ROCOF and rotor speed are high. Until the frequency nadir (FN), the gain decreases with the ROCOF and rotor speed. After the FN, the gain decreases only with the rotor speed. The simulation results demonstrate that the proposed scheme improves the FN and maximum ROCOF while ensuring the stable operation of a DFIG under various wind conditions irrespective of the disturbance conditions by adaptively changing the control gain with the ROCOF and rotor speed, even if the wind speed decreases and a consecutive disturbance occurs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Techno-economic optimization of renewable urea production for sustainable agriculture and CO 2 utilization

Abstract Urea is the most used nitrogen fertilizer due to its ease of storage, transportation, and application. It is made by combining ammonia and carbon dioxide (CO 2 ), both of which are produced predominantly from fossil fuels at present. The recent momentum behind ammonia production using renewable-powered electrolysis offers an opportunity to both make urea in a more sustainable way and utilize CO 2 from external sources. In this work, we present a techno-economic optimization model to minimize the cost of making urea in this way. The model allows for time-varying chemical production in response to renewable variability by simultaneously optimizing production facility design and hourly operation. We performed a case study for Minnesota considering the use of byproduct CO 2 from bioethanol production. We found that the present-day levelized cost of renewable urea is between $268 mt −1 and $413 mt −1 at likely implementable production scales up to 250 000 mt yr −1 . This is within the range of historical conventional urea prices while offering at least 78% carbon intensity reduction. Projecting to 2030, there is a clear economic case for renewable urea production with levelized cost as low as $135 mt −1 due to technology improvement and electrolysis manufacturing expansion, facilitating a urea production scale increase to 525 000 mt yr −1 . Optimal facilities use wind energy, with hydrogen and ammonia production operating in a flexible, time-varying way to minimize battery and hydrogen storage capacities. Urea production operates near steady state due to the relatively low cost of intermediate ammonia buffer storage. A mix of imported methane and locally produced hydrogen are used to provide heat for steam consumed in the urea synthesis.

Chemistry↗

Improving the Representation of Hydropower in Production Cost Models

One of the challenges of a high-renewable, low-carbon system is that grid operators will no longer be able to count on fossil-fired generation should wind miss its forecast or modeling errors create shortage issues, and this change has operational and reliability implications that affect variable renewable energy integration. Hydropower can help in that it can provide many of the services that have been traditionally provided by fossil generation. However, getting the most from hydropower can be challenging in that its capabilities vary with time and are affected by other water users' needs, two complexities that are not well represented in most of today's production cost models (PCMs). This work is an early step in addressing these gaps and making the most of hydropower's capabilities.

cost model↗

Electrolysis' Potential Value for Supporting the Electrical Grid

The H2@Scale concept includes a value proposition for electrolysis that benefits both hydrogen markets and the electricity system. Electrolysis has the potential to be an alternative low-cost hydrogen source by using low-price electricity that may be available for only a limited number of hours annually. It also has the potential to provide value to the grid through use of that low-cost electricity. By doing so, electrolysis can create a price floor which could support additional investment in low-cost, dispatch-constrained electricity (LDE) generation such as photovoltaic solar, wind, and nuclear. The rapid-response characteristics of low-temperature electrolysis enables it to also provide ancillary services to the grid such as operating reserves and frequency control. We evaluate the economic performance of water electrolysis in a selection of electricity markets - both current and potential future markets. To perform that evaluation, we collect locational marginal prices (LMPs) in each market, calculate levelized hydrogen costs, and compare them to cost estimates of producing hydrogen via steam methane reforming of natural gas. Those calculations also include electolyzer capital and operating costs. We perform the calculations across a range of capacity factors to identify the minimum levelized hydrogen cost in that range. We discuss the implications of that capacity factor for each market analyzed. For a couple of the analyzed electricity markets, we include the potential value of providing ancillary services in the calculation and discuss those impacts. LDE generation has been shown to suppress electricity prices because it generates electricity when the resource is available (i.e., the sun is shining, wind is blowing, nuclear heat is being produced) and the generation cannot be reduced without an economic penalty. Price suppression is likely to reduce investment in those technologies due to reductions in projected income of each marginal unit. If electrolyzers are willing to pay for the LDE, it could provide a price floor for electricity. We analyze how setting a price for LDE could impact the electricity generation fleet, the availability of LDE, and the potential levelized costs of producing hydrogen using that LDE. Among other results, we will present a set of supply curves showing potential production costs and availability for hydrogen produced from LDE in a future with high penetrations of renewable electricity on the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Decarbonization and technology cost drivers: considerations for potential future thermoelectric water use in the power sector

The power sector is currently undergoing significant changes, driven by a combination of factors, including decarbonization and technology innovation. This study aims to assess implications of these drivers on U.S. power sector technology futures and the associated water and environmental implications for cooling thermoelectric power plants. Specifically, we evaluate four decarbonization scenarios for the contiguous United States that vary in assumptions concerning demand growth and technology costs, with technology costs driving alternative outcomes that prioritize either technologies that require low amounts of water (such as wind, solar, and battery) or high amounts of water (such as nuclear and carbon capture and storage). These scenarios are executed in a power sector capacity expansion model and compared to two reference scenarios that assume status quo with policy and cost drivers. Our analysis indicates that future U.S. thermoelectric water withdrawals could decrease by 25%–60%, but water consumption could more than triple in some scenarios. These changes are driven by a combination of retirement of some power facilities, shifts in cooling technologies, and new technology deployment. The water use patterns vary across the United States, with the eastern regions demonstrating a lot more variability in water consumption across scenarios than western regions. However, local concerns can influence these possible investments, since increased water consumption can exacerbate water scarcity, leading to conflicts among competing users and affecting regional social, environmental, and economic dynamics. Future work should consider possible costs associated with alternate water sources, as well as improve the representation of water constraints within simulations. Inclusion of extreme events and alternate modeling platforms (e.g. production cost modeling and resource adequacy) may also be warranted to further stress test the robustness of these possible technology futures. Such assessments will be critical for ensuring decarbonization and other infrastructure-oriented investments lead to a reliable and resilient power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermal Management System of an Outer-Rotor-Motor-Based Traction Drive With Integrated Power Electronics in its Central Cavity

Increasing power densities of electric vehicle traction drive systems necessitates combining the electric motor and the power electronics into one unit. A compact, integrated traction drive unit with fewer components also drives production costs down, enabling wider adoption of electric vehicles. However, the integration of power electronics in the electric machine is associated with challenges of designing an effective thermal management solution for the combined traction drive system. This paper focuses on the thermal management approach selected for Oak Ridge National Laboratory’s outer-rotor-motor-based integrated traction drive and evaluates its potential performance. The outer-rotor-motor configuration provided an opportunity for integration of the six-phase inverter in the available space in the central cavity of the internal stator. A cylindrical inverter enclosure with integrated coolant (water-ethylene glycol) channels in its walls was designed to enable heat removal from the power electronics. Numerical thermal-fluid modeling and initial channel/fin optimization results for the cylindrical heat sink are presented here. As permanent magnets are integrated in a high-speed (20 000 RPM) outer rotor, forced air convection provides cooling for the magnets. The magnets were segmented axially to mitigate the eddy current losses. Heat generated in the stator windings and laminations is removed by water-ethylene glycol coolant circulating in interpolar T-shape ceramic heat exchangers inserted between windings. General design concepts and numerical thermal-fluid simulations illustrating the electric motor thermal management solution are also presented.

Kekelia, Bidzina↗

A Comparison of Pressure Measurements Between a Full-Scale and a 1/16-Scale F/A-18 Twin Tail During Buffet

In 1993, tail buffet tests were performed on a full-scale, production model F/A-18 in the 80-by-120 Foot Wind Tunnel at NASA Ames Research Center. Steady and unsteady pressures were recorded on both sides of the starboard vertical tail for an angle of attack range of 20 to 40 degrees and at a sideslip range of -16 to 16 degrees at freestream velocities up to 100 knots (Mach 0.15, Reynolds number 1.23 x 10(exp 7)). The aircraft was equipped with removable leading edge extension (LEX) fences that are used in flight to reduce tail buffet loads. In 1995, tail buffet tests were performed on a 1/6-scale F-18 A/B model in the Transonic Dynamics Tunnel (TDT) at NASA Langley Research Center. Steady and unsteady pressures were recorded on both sides of both vertical tails for an angle-of-attack range of 7 to 37 degrees at freestream velocities up to 65 knots (Mach 0.10). Comparisons of steady and unsteady pressures and root bending moments are presented for these wind-tunnel models for selected test cases. Representative pressure and root bending moment power spectra are also discussed, as are selected pressure cross-spectral densities.

Moses, Robert W.↗

Hybrid Energy System Modeling in Modelica

In this paper, a Hybrid Energy System (HES) configuration is modeled in Modelica. Hybrid Energy Systems (HES) have as their defining characteristic the use of one or more energy inputs, combined with the potential for multiple energy outputs. Compared to traditional energy systems, HES provide additional operational flexibility so that high variability in both energy production and consumption levels can be absorbed more effectively. This is particularly important when including renewable energy sources, whose output levels are inherently variable, determined by nature. The specific HES configuration modeled in this paper include two energy inputs: a nuclear plant, and a series of wind turbines. In addition, the system produces two energy outputs: electricity and synthetic fuel. The models are verified through simulations of the individual components, and the system as a whole. The simulations are performed for a range of component sizes, operating conditions, and control schemes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End of Life Management: Solar Photovoltaic Panels

Technical potential of materials recovered from end-of-life solar PV panels could exceed $15 billion by 2050. The global solar photovoltaic (PV) boom currently underway will represent a significant untapped business opportunity as decommissioned solar panels enter the waste stream in the years ahead, according to a report released today by the International Renewable Energy Agency (IRENA) and the International Energy Agency's Photovoltaic Power Systems Programme (IEA-PVPS). The report, End-of-Life Management: Solar Photovoltaic Panels, is the first-ever projection of PV panel waste volumes to 2050 and highlights that recycling or repurposing solar PV panels at the end of their roughly 30-year lifetime can unlock a large stock of raw materials and other valuable components. It estimates that PV panel waste, comprised mostly of glass, could total 78 million tonnes globally by 2050. If fully injected back into the economy, the value of the recovered material could exceed USD 15 billion by 2050. This potential material influx could produce 2 billion new panels or be sold into global commodity markets, thus increasing the security of future PV supply or other raw material-dependent products. The report suggests that addressing growing solar PV waste, and spurring the establishment of an industry to handle it, would require: the adoption of effective, PV-specific waste regulation; the expansion of existing waste management infrastructure to include end-of-life treatment of PV panels, and; the promotion of ongoing innovation in panel waste management. In most countries, PV panels fall under the classification of 'general waste' but the European Union (EU) was the first to adopt PV-specific waste regulations, which include PV-specific collection, recovery, and recycling targets. EU's directive requires all panel producers that supply PV panels to the EU market (wherever they may be based) to finance the costs of collecting and recycling end-of-life PV panels put on the market in Europe. End-of-Life Management: Solar Photovoltaic Panels, is the second of several solar-focused publications IRENA is releasing this summer. Last week, IRENA released The Power to Change, which predicts average costs for electricity generated by solar and wind technologies could decrease by between 26 and 59 per cent by 2025. Later this week, IRENA will release Letting in the Light: How Solar Photovoltaics Will Revolutionize the Electricity System - which provides a comprehensive overview of solar PV across the globe and its prospects for the future.

14 SOLAR ENERGY↗

On the Use of Satellite Nightlights for Power Outages Prediction

Hurricanes are a dominant disaster in the Caribbean, always causing serious power outages throughout the islands. Hurricane Maria was a prime example, causing unimaginable destruction of the power infrastructure of Puerto Rico (PR). Consequently, one month after the hurricane landfall, approximately 80% of the population was still without power. After an event of such massive destruction, the electric power restoration process progresses very slowly. This timeline can be improved using power outage (PO) forecast models that help identify the vulnerable places before the hurricane landfall. Generally, these models are trained with historical power outages records, associated data on weather conditions, and additional information about the natural and built environments. However, PO records are often difficult to acquire, and, in many instances, the power utility companies may not record them. This study utilizes a satellite-based Visible Infrared Imaging Radiometer Suite (VIIRS) night light data product as a surrogate for the power delivery to predict hurricane-induced PO in areas having limited to nonexistent historical data records. The processed satellite data is then used along with geographic variables, and simulated weather data to formulate machine learning-based algorithms to predict PO for future hurricane events. These models are applied and validated in the context of the PR catastrophic storm, Hurricane Maria.

54 ENVIRONMENTAL SCIENCES↗

Naval Station Newport Wind Resource Assessment

The U.S. Environmental Protection Agency (EPA) launched the RE-Powering America's Land initiative to encourage development of renewable energy (RE) on potentially contaminated land and mine sites. EPA is collaborating with the U.S. Department of Energy's (DOE's) National Renewable Energy Laboratory (NREL) to evaluate RE options at Naval Station (NAVSTA) Newport in Newport, Rhode Island where multiple contaminated areas pose a threat to human health and the environment. Designated a superfund site on the National Priorities List in 1989, the base is committed to working toward reducing the its dependency on fossil fuels, decreasing its carbon footprint, and implementing RE projects where feasible. The Naval Facilities Engineering Service Center (NFESC) partnered with NREL in February 2009 to investigate the potential for wind energy generation at a number of Naval and Marine bases on the East Coast. NAVSTA Newport was one of several bases chosen for a detailed, site-specific wind resource investigation. NAVSTA Newport, in conjunction with NREL and NFESC, has been actively engaged in assessing the wind resource through several ongoing efforts. This report focuses on the wind resource assessment, the estimated energy production of wind turbines, and a survey of potential wind turbine options based upon the site-specific wind resource.

14 SOLAR ENERGY↗

A Comparison of Pressure Measurements Between a Full-Scale and a 1/6-Scale F/A-18 Twin Tail During Buffet

In 1993, tail buffet tests were performed on a full-scale, production model F/A-18 in the 80 x 120-foot Wind Tunnel at NASA Ames Research Center. Steady and unsteady pressures were recorded on both sides of the starboard vertical tail for an angle-of-attack range of 20 to 40 degrees and at a sideslip range of -1 6 to 16 degrees at freestream velocities up to 100 knots (Mach 0.15, Reynolds number 1.23 x 10(exp 7). The aircraft was equipped with removable leading edge extension (LEX) fences that are used in flight to reduce tail buffet loads. In 1995, tail buffet tests were performed on a 1/6-scale F-18 A/B model in the Transonic Dynamics Tunnel (TDT) at NASA Langley Research Center. Steady and unsteady pressures were recorded on both sides of both vertical tails for an angle-of-attack range of 7 to 37 degrees at freestream velocities up to 65 knots (Mach 0.10). Comparisons of steady and unsteady pressures and root bending moments are presented for these wind-tunnel models for selected test cases. Representative pressure and root bending moment power spectra are also discussed, as are selected pressure cross-spectral densities.

Moses, Robert W.↗

Using waste CO 2 from corn ethanol biorefineries for additional ethanol production: life‐cycle analysis

Abstract Corn ethanol plants generate high‐purity carbon dioxide (CO 2 ) while producing ethanol. If that CO 2 could be converted into ethanol by carbon capture and utilization technologies it would be possible to increase ethanol production more than 37% without additional corn grain inputs. Gas fermentation processes use microbes to convert carbon‐containing gases into ethanol and so have the potential to be used with the CO 2 from biorefineries for this purpose. However, as CO 2 utilization technologies for converting thermodynamically stable CO 2 are typically energy intensive, it is necessary to evaluate the related life‐cycle greenhouse gas (GHG) emissions (carbon intensities or CIs) to see whether there are actual emission reduction benefits. In this study, we evaluate the CIs of ethanol produced from high‐purity CO 2 in corn ethanol plants by gas fermentation plus electrochemical reduction. Our analysis shows that the sources of electricity and hydrogen are key drivers of CO 2 ‐based ethanol's GHG emissions. With wind electricity, the design cases show the potential of near‐zero CI ethanol (1.1 g CO 2 e/MJ), but that can increase to up to 331–531 g CO 2 e/MJ when today's U.S. Midwest electricity mix is used. To avoid the renewable electricity intermittency issue, we considered a power purchase agreement option using wind electricity 40% of the time and using the regional mix for the rest, which provides a 42% GHG emission reduction from the CI of gasoline. © 2020 The Authors and UChicago Argonne, LLC, Operator of Argonne National Laboratory. Biofuels, Bioproducts and Biorefining published by Society of Chemical Industry and John Wiley & Sons, Ltd.

09 BIOMASS FUELS↗

Valuing EV Managed Charging for Bulk Power Systems

When and where electric vehicle (EV) charging occurs has significant implications for power systems supporting widespread EV adoption, especially with high shares of wind and solar generation. This study extends previous works by leveraging detailed simulation models for EV adoption, EV use, EV charging, and bulk power system operations, and by linking them with methods for describing charging flexibility at both the individual vehicle and aggregate levels. This technical potential study focuses on how the value of EV managed charging (EVMC) changes depending on charging flexibility type (within-charging session or within-week scheduling), dispatch mechanism (direct load control or one of several price-based mechanisms), and managed charging participation rate. We show that naively aggregating EV charging flexibility from individual vehicles into megawatt-scale resources grossly overestimates the flexibility of the fleet, because such aggregate models can unrealistically pair, e.g., one already-fully-charged vehicle's ability to increase load with another already-charging vehicle's ability to accept more charge, effectively requesting a charging rate that is infeasible for the latter vehicle. We find per-vehicle bulk system value is highest at low participation rates for all dispatch mechanisms. Factoring in production cost savings, avoided firm capacity savings, and combustion-related power sector emissions savings, we estimate the value of EVMC at low participation rates (5%) to be $33/vehicle-year to $69/vehicle-yr for within-session charging flexibility and $40/vehicle-yr to $120/vehicle-yr for within-week charging flexibility in an envisioned 2038 New England power system and monetary value reported in 2016 U.S. dollars. At 100% participation, per-vehicle value declines to $25/vehicle-yr to $31/vehicle-yr for within-session charging flexibility and to $29/vehicle-yr to $36/vehicle-yr for within-week charging flexibility; however, 100% participation yields the highest total system savings.

ADVANCED PROPULSION SYSTEMS↗

Challenges and Possible Solutions in Aeroelastic Modeling for the Distributed Wind Industry

Aeroelastic modeling (AM) is the primary methodology for structural and performance assessment of any wind turbine; it provides an understanding of the impact of design parameters on turbine loading and power response before witnessing it in the field. Despite these advantages, the use of AM in the distributed wind technology (DWT) sector is limited. This article represents a short summary of an in-depth assessment by the authors of the status of AM and its role within the distributed wind technology design standards. The research gathered input and feedback from a large number of U.S. and international stakeholders, reviewed technical strengths and weaknesses of the current edition of the design standards, analyzed the minutes from recent industry workshops and meetings, collected publicly available AM templates, and provided an evaluation of the existing AM codes. Several goals were achieved including providing strategies for the load assessment categorization of turbines based on rotor swept area and archetype, and guidance for AM verification and validation. Recommendations within this study will advance the value and the ease-of-use of AM, thereby allowing the industry to better capitalize this underutilized tool, resulting in a more efficient design process, an easier path to certification, and overall better and more reliable distributed wind technology products.

17 WIND ENERGY↗

Electric Vehicle Managed Charging: Estimating the Potential Bulk Power System Value

With more and more electric vehicles (EVs) on the road, the grid of the future can greatly benefit from EV managed charging, which coordinates charging based on people's travel needs, electricity supply, and grid conditions. The added flexibility could be especially valuable for the bulk power system as it transitions to high shares of variable renewable generation, like wind and solar. Numerous studies have estimated the potential value of EV managed charging. In this study, NREL leveraged more detailed modeling of EV adoption, use, charging, and bulk power system operations to understand the potential value. Unique to this study, NREL modeled different charging flexibility types and dispatch mechanisms - as well as participation rates among drivers in having their EV charging managed - starting from vehicle-specific descriptions of charging flexibility. The study is based on a passenger light-duty vehicle adoption scenario with 100% EV sales by 2035 and a New England power system in 2038 with 84% clean generation and 26% of the electric load met by net imports. The 2038 New England light-duty vehicle feet is modeled as 45% electric.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Dispatch Control with PEV Charging and Renewables for Multiplayer Game Application

This paper presents a demand response model for a hypothetical microgrid that integrates renewable resources and plug-in electric vehicle (PEV) charging systems. It is assumed that the microgrid has black start capability and that external generation is available for purchase while grid connected to satisfy additional demand. The microgrid is developed such that in addition to renewable, non-dispatchable generation from solar, wind and run of the river hydroelectric resources, local dispatchable generation is available in the form of small hydroelectric and moderately sized gas and coal fired facilities. To accurately model demand, the load model is separated into independent residential, commercial, industrial, and PEV charging systems. These are dispatched and committed based on a mixed integer linear program developed to minimize the cost of generation and load shedding while satisfying constraints associated with line limits, conservation of energy, and ramp rates of the generation units. The model extends a research tool to longer time frames intended for policy setting and educational environments and provides a realistic and intuitive understanding of beneficial and challenging aspects of electrification of vehicles combined with integration of green electricity production.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Rethinking the Price Formation Problem–Part 1: Participant Incentives under Uncertainty

Operators of organized wholesale electricity markets attempt to form prices in such a way that the private incentives of market participants are consistent with a socially optimal commitment and dispatch schedule. In the U.S. context, several competing price formation schemes have been proposed to address the non-convex production cost functions characteristic of most generation technologies. Here, this paper considers how the design and analysis of price formation policies for non-convex markets are affected by the uncertainty inherent in electricity demand and supply. We argue that by excluding uncertainty, the analytical framework underlying existing policies mischaracterizes the incentives of market participants, leading to inefficient price formation and poor incentives for flexibility. We establish favorable theoretical properties of a new construct, ex ante convex hull pricing , and demonstrate the difference between this idealized benchmark and existing methods on a large-scale test system. Given increased operational uncertainty with a transition to wind and solar generation, distortions caused by poor incentives for flexibility are likely to grow without improved price formation in organized wholesale markets.

24 POWER TRANSMISSION AND DISTRIBUTION↗