Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WIRING SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Mars 2020 Perseverance Rover SHERLOC Instrument Isolation System

The NASA Jet Propulsion Laboratory (JPL) successfully landed the Mars 2020 Perseverance Rover at Jezero Crater on the Martian surface. Perseverance’s main mission objective is to cache Martian rock and regolith samples in hermetically sealed tubes to be brought back to Earth by future missions. To achieve this goal the rover is equipped with a 2-meter-long Robotic Arm (RA) which manipulates the Turret to interact with the surface. The Turret is comprised of science instruments and tools that enable surface sampling and science. The backbone of the Turret hardware is the Rotary Percussive Coring Drill. The science instruments, which are directly mounted to the structural housing of this drill, must be able to withstand not only the launch and entry, descent and landing (EDL) loads of the vehicle but also the dynamic percussive environment, induced by the drill throughout surface operations. This paper discusses the technical hardware design, development and testing of a vibration isolation system to protect the Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) Instrument from these dynamic environments. The hardware design aspect of this problem was limited by both size and mass constraints. The Turret is tightly configured and the physical space in which hardware can reside is restricted due to multiple axes of surface interaction points. Another driving requirement is the extreme range of thermal non-operational environment from -135C to +90C. This, in addition to SHERLOC being a heavier instrument than previously integrated on a turret, made the use of isolation systems employed on previous rover missions problematic. The final design incorporates custom wire mesh springs preloaded within titanium hexapod struts equipped with flexure ends. Custom versions of commercially available wire mesh springs were designed and tested. These custom springs differed in dimension, density and stiffness from the off the shelf options. The newly designed springs went through various stages of flight acceptance testing. Detailed physics-based modeling to understand what loads the isolation system would experience was used to define the test conditions for the springs and entire isolation subsystem. The testing program developed around this was extensive to fully characterize the isolation performance over cleanliness levels, temperature and life. Another major aspect of this work was developing a method of replicating the drill’s percussive environment for performance and life testing of Turret mounted hardware. Attaching the instrument to an operating drill for testing was not a viable option. A method of using a Highly Accelerated Life Test (HALT) table was developed and applied across the project as the most representative and tunable option to physically simulate this new environment. This method, along with launch environment random vibration testing, was used to build an entire dynamic qualification and flight hardware test program. The results of the design, modeling, testing and analysis of the SHERLOC Isolation System is described throughout the following paper.

Krafchak, Todd↗

Influence of the airflow speed along transmission lines on the DC corona discharge loss, using finite element approach

Corona discharge is of great interest from the physical point of view and due to its numerous practical applications in industry and especially one of the most important sources of loss in the high voltage transmission lines. This paper provides guidelines for the amount of electric loss caused by corona phenomenon occurred around a DC high voltage wire placed between two flat plates and influence of wind speed rate on the amount of corona loss using COMSOL Multiphysics. So electric potential distribution patterns and charge density diffusion around the wire are studied in this article.

42 ENGINEERING↗

Design of Transportation Frames for 650 MHz Cavities and High Power Couplers

This work presents the design of a transportation frame system for 650~MHz superconducting radio frequency cavities with high power couplers. Modal analysis identified the coupler antenna as the critical component with a 38~Hz natural frequency, leading to a dual-frame design with wire rope isolators that achieves 82\% vibration attenuation at the critical frequency. The system meets all transportation requirements, fits within standard shipping crates, and maintains structural integrity under 12g shock loads.

42 ENGINEERING↗

Design of Transportation Frames for 650 MHz Cavities and High Power Couplers

This work presents the design of a transportation frame system for 650~MHz superconducting radio frequency cavities with high power couplers. Modal analysis identified the coupler antenna as the critical component with a 38~Hz natural frequency, leading to a dual-frame design with wire rope isolators that achieves 82\% vibration attenuation at the critical frequency. The system meets all transportation requirements, fits within standard shipping crates, and maintains structural integrity under 12g shock loads.

Argento, Marco [Fermilab]↗

Development of the RANCOR Rotary-Percussive Coring System for Mars Sample Return

A RANCOR drill was designed to fit a Mars Exploration Rover (MER) class vehicle. The low mass of 3 kg was achieved by using the same actuator for three functions: rotation, percussions, and core break-off. Initial testing of the drill exposed an unexpected behavior of an off-the-shelf sprag clutch used to couple and decouple rotary-percussive function from the core break off function. Failure of the sprag was due to the vibration induced during percussive drilling. The sprag clutch would back drive in conditions where it was expected to hold position. Although this did not affect the performance of the drill, it nevertheless reduced the quality of the cores produced. Ultimately, the sprag clutch was replaced with a custom ratchet system that allowed for some angular displacement without advancing in either direction. Replacing the sprag with the ratchet improved the collected core quality. Also, premature failure of a 300-series stainless steel percussion spring was observed. The 300-series percussion spring was ultimately replaced with a music wire spring based on performances of previously designed rotary-percussive drill systems.

Paulsen, Gale↗

Inductance and near fields of a loop antenna in a cold magnetoplasma in the whistler frequency band

The influence of a magnetoplasma on the inductance of a circular loop antenna oriented perpendicular to the ambient static magnetic field and operated in the whistler frequency band is studied. Based on a strict electrodynamic approach, the analytical treatment of the antenna reactance is performed for a uniform rf current distribution along the antenna wire. Calculations are made for plasma parameters and operating frequencies typical for active ionospheric experiments and laboratory rf (helicon) sources of dense magnetized plasmas. It is shown that the plasma influence on the inductance of the loop antenna remains relatively weak, even for antennas with dimensions close to half of the longitudinal whistler wavelength, when the rf field distribution in the antenna near zone is strongly different from that in vacuum. The theoretical predictions are confirmed by measurements performed on the large KROT plasma device. The results obtained are of crucial importance for the preparation of active ionospheric experiments and for the matching of loop antennas used in laboratory rf sources of dense magnetized plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Long‐Range Non‐Coulombic Electron–Electron Interactions between LaAlO 3 /SrTiO 3 Nanowires

Abstract The LaAlO 3 /SrTiO 3 system exhibits unusual magnetic and superconducting behavior arising from electron–electron interactions whose physical origin is not well understood. Quantum transport techniques, especially those involving mesoscopic geometries, can offer insight into these interactions. Here evidence for long‐range electron–electron interactions in LaAlO 3 /SrTiO 3 nanowires, measured through the phenomenon of frictional drag, is reported, in which current passing through one nanowire induces a voltage across a nearby electrically isolated nanowire. Frictional drag mediated by the Coulomb interaction is predicted to decay exponentially with interwire separation, but with the LaAlO 3 /SrTiO 3 nanowire system it is found to be nearly independent of separation. Frictional drag experiments performed with three parallel wires demonstrate long‐range frictional coupling even in the presence of an electrically grounded central wire. Collectively, these results provide evidence for a new long‐range non‐Coulombic electron–electron interaction unlike anything previously reported for semiconducting systems.

Tang, Yuhe↗

Feasibility of remote evaporation and precipitation estimates

Remote sensing by means of stereo images obtained from flown cameras and scanners provides the potential to monitor the dynamics of pollutant mixing over large areas. Moreover, stereo technology may permit monitoring of pollutant concentration and mixing with sufficient detail to ascertain the structure of a polluted air mass. Consequently, stereo remote systems can be employed to supply data to set forth adequate regional standards on air quality. A method of remote sensing using stereo images is described. Preliminary results concerning the planar extent of a plume based on comparison with ground measurements by an alternate method, e.g., remote hot-wire anemometer technique, are supporting the feasibility of using stereo remote sensing systems.

Sadeh, W. Z.↗

A generic method for interfacing IEDs using low voltage interfaces to real-time simulators with hardware in the loop

This study presents an interface method (IM) to interconnect real-time simulators (RTSs) without amplifiers for different intelligent electronic devices (IEDs), such as protective relays, smart meters, and other devices. It is a significant topic for the power systems protection community because there are many protection devices with different requirements. These protection devices have pinouts that measure bus voltages/currents and breaker pole states and generate trip/close pulse signals. Most of the emulation test beds with RTSs and HIL need amplifiers to connect IEDs from different product manufacturers because the low-voltage interface levels are not available in some instruction manuals. Additionally, commercial amplifiers have cutoff frequency limitations and have an excessive cost when several IEDs are wired onto test beds. Then, the validation of protection and control systems with RTSs and IEDs in the loop from different vendors without amplifiers results in an unfeasible alternative. In this paper, the IM was based on using an interface box, power source, and RTS to identify IED inputs/outputs. Here, the sequence to recognize IED pinouts and calculate the current/voltage scaling factors is described. The IM was validated satisfactorily with RTS and a protection device (with unknown pinouts) in the loop.

42 ENGINEERING↗

An adaptive structure data acquisition system using a graphical-based programming language

An example of the implementation of data fusion using a PC and a graphical programming language is discussed. A schematic of the data acquisition system and user interface panel for an adaptive structure test are presented. The computer programs (a series of icons 'wired' together) are also discussed. The way in which using graphical-based programming software to control a data acquisition system can simplify analysis of data, promote multidisciplinary interaction, and provide users a more visual key to understanding their data are shown.

Baroth, Edmund C.↗

Science data systems

Video film converter for data processing, linear feedback shift registers, and woven plated wire memory storage units for science missions

MEMORY STORAGE UNIT↗

Laboratory Testing to Assess the Feasibility of Polyurethane Flat Belts for Marine Energy Applications

Polyurethane flat belts have received limited scientific attention as load-bearing elements in marine energy systems, particularly in applications involving dynamic tensile and bending loads. This study evaluates their potential as a replacement for traditional wire ropes in marine energy applications, with a focus on their ability to be integrated into winch-driven wave energy converters where bending and tensile stresses can make long-term operation difficult. Polyurethane belts are hypothesized to offer enhanced fatigue resistance due to their reduced thickness in the bending plane and therefore lower bending stresses. This research involves a series of tests utilizing the National Renewable Energy Laboratory’s (NREL) Large-Amplitude Motion Platform to replicate the dynamic conditions experienced by mooring lines of winch-based point-absorber-type marine energy converters. The conditions tested include unequal coiling and uncoiling tensions and load cases resulting from the device’s unconstrained movement relative to its anchor, such as twisting and off-axis loading. Results from this study show that polyurethane flat belts can achieve more than 198 percent of the fatigue life of a conventional wire rope under similar load profiles. The stress concentrations resulting from off-axis loading and cumulative twist beyond the system’s allowable limits have been identified as potential failure modes for flat belt mooring lines used in winch-driven wave energy converters deployed in ocean environments. To mitigate these risks, the use of anti-spin systems and fairleads designed to accommodate off-axis loading while limiting twist accumulation is recommended.

13 HYDRO ENERGY↗

Comparison Testings between Two High-temperature Strain Measurement Systems

An experimental evaluation was conducted at NASA Lewis Research Center to compare and contrast the performance of a newly developed resistance strain gage, the PdCr temperature-compensated wire strain gage, to that of a conventional high-temperature extensometry. The evaluation of the two strain measurement systems was conducted through the application of various thermal and mechanical loading spectra using a high-temperature thermomechanical uniaxial testing system equipped with quartz lamp heating. The purpose of the testing was not only to compare and contrast the two strain sensors but also to investigate the applicability of the PdCr strain gage to the testing environment typically employed when characterizing the high-temperature mechanical behavior of structural materials. Strain measurement capabilities to 8OO C were investigated with a nickel base superalloy IN100 substrate material, and application to titanium matrix composite (TMC) materials was examined with the SCS-6/Ti-15-3 08 system. PdCr strain gages installed by three attachment techniques, namely, flame spraying, spot welding and rapid infrared joining were investigated.

Lei, J.-F.↗

Studies of acoustic-electric feed-throughs for power transmission through structures

There are numerous engineering design problems where the use of wires to transfer power and communicate data thru the walls of a structure is prohibitive or significantly difficult that it may require a complex design. Using physical feedthroughs in such systems may make them susceptible to leakage of chemicals or gasses, loss of pressure or vacuum, as well as difficulties in providing adequate thermal or electrical insulation. Moreover, feeding wires thru a wall of a structure reduces the strength of the structure and makes the structure prone to cracking due to fatigue that can result from cyclic loading and stress concentrations. One area that has already been identified to require a wireless alternative to electrical feedthroughs is the container of the Mars Sample Return Mission, which will need wireless sensors to sense a pressure leak and to avoid potential contamination. The idea of using elastic or acoustic waves to transfer power was suggested recently by [Y. Hu, et al., July 2003]. This system allows for the avoidance of cabling or wiring. The technology is applicable to the transfer of power for actuation, sensing and other tasks inside any sealed container or vacuum/pressure vessel. An alternative approach to the modeling presented previously [Sherrit et a., 2005] used network analysis to solve the same problem in a clear and expandable manner. Experimental tests on three different designs of these devices were performed. The three designs used different methods of coupling the piezoelectric element to the wall. In the first test the piezoelectric material was bolted using a backing structure. In the second test the piezoelectric was clamped after the application of grease and finally the piezoelectric element was attached using a conductive epoxy. The mechanical clamp with grease produced the highest measured efficiency of 53% however this design was the least practical from a fabrication viewpoint. The power transfer efficiency of conductive epoxy joint was 40% and the stress bolts (12%).

ultrasonics↗

Pixelized Device Control Actuators for Large Adaptive Optics

A fully integrated, compact, adaptive space optic mirror assembly has been developed, incorporating new advances in ultralight, high-performance composite mirrors. The composite mirrors use Q-switch matrix architecture-based pixelized control (PMN-PT) actuators, which achieve high-performance, large adaptive optic capability, while reducing the weight of present adaptive optic systems. The self-contained, fully assembled, 11x11x4-in. (approx.= 28x28x10-cm) unit integrates a very-high-performance 8-in. (approx.=20-cm) optic, and has 8-kHz true bandwidth. The assembled unit weighs less than 15 pounds (=6.8 kg), including all mechanical assemblies, power electronics, control electronics, drive electronics, face sheet, wiring, and cabling. It requires just three wires to be attached (power, ground, and signal) for full-function systems integration, and uses a steel-frame and epoxied electronics. The three main innovations are: 1. Ultralightweight composite optics: A new replication method for fabrication of very thin composite 20-cm-diameter laminate face sheets with good as-fabricated optical figure was developed. The approach is a new mandrel resin surface deposition onto previously fabricated thin composite laminates. 2. Matrix (regenerative) power topology: Waveform correction can be achieved across an entire face sheet at 6 kHz, even for large actuator counts. In practice, it was found to be better to develop a quadrant drive, that is, four quadrants of 169 actuators behind the face sheet. Each quadrant has a single, small, regenerative power supply driving all 169 actuators at 8 kHz in effective parallel. 3. Q-switch drive architecture: The Q-switch innovation is at the heart of the matrix architecture, and allows for a very fast current draw into a desired actuator element in 120 counts of a MHz clock without any actuator coupling.

Knowles, Gareth J.↗

Spin-related phenomena in spin 3/2 charge carrier holes systems

Charge carrier holes provide a remarkable system for spintronics and quantum information technology. In this review paper, I discuss spin-related phenomena in three-dimensional and low-dimensional hole systems. Special attention is paid to the mutual transformation of heavy and light holes at the boundary of quantum wells and wires that governs values of parameters defining hole spectra in quantum wells, wires and dots, such as effective masses, g-factors and Rashba and Dresselhaus spin–orbit constants. Recently, topological phenomena in condensed matter systems, such as emergence of Majorana zero modes and non-Abelian phases in the fractional quantum Hall effect, sparked considerable interest of researchers. Charge carrier holes turn out to be a remarkable setting for possible observation of these phenomena and advancing topological quantum computing. I discuss the spectra and wavefunctions of two-dimensional holes in magnetic field. While there is a semiclassical range of parameters when heavy and light holes can be described by equidistant Landau levels, ground-level holes and holes in a few low-lying excited states behave as species completely different from electrons. Especially interesting are crossings in hole spectra in magnetic field. Hole–hole interactions can substantially differ from electron–electron interactions. Apart from the difference in exchange splitting, this shows in possible emergence of even denominator fractional quantum Hall state in the ground hole level in magnetic field. I also briefly discuss spintronic phenomena, such as mutual transformation of angular momentum (spin) of holes and electric current, as well as spin-related interference effects in hole transport. Recent developments in a system of Ge hole quantum dots offer new perspectives for hole-based systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High Temperature Superconducting Underground Cable

The purpose of this Project was to design, build, install and demonstrate the technical feasibility of an underground high temperature superconducting (HTS) power cable installed between two utility substations. In the first phase two HTS cables, 320 m and 30 m in length, were constructed using 1st generation BSCCO wire. The two 34.5 kV, 800 Arms, 48 MVA sections were connected together using a superconducting joint in an underground vault. In the second phase the 30 m BSCCO cable was replaced by one constructed with 2nd generation YBCO wire. 2nd generation wire is needed for commercialization because of inherent cost and performance benefits. Primary objectives of the Project were to build and operate an HTS cable system which demonstrates significant progress towards commercial progress and addresses real world utility concerns such as installation, maintenance, reliability and compatibility with the existing grid. Four key technical areas addressed were the HTS cable and terminations (where the cable connects to the grid), cryogenic refrigeration system, underground cable-to-cable joint (needed for replacement of cable sections) and cost-effective 2nd generation HTS wire. This was the world’s first installation and operation of an HTS cable underground, between two utility substations as well as the first to demonstrate a cable-to-cable joint, remote monitoring system and 2nd generation HTS.

24 POWER TRANSMISSION AND DISTRIBUTION↗