Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Validation Studies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

WE-G-BRD-09: Prediction of Local Control/Failure by Using Feature Histogram Selection in Follow-Up T2-Weighted MR Image in Spinal Tumors After Stereotactic Body Radiation Therapy

Purpose: In follow-up T2-weighted MR images of spinal tumor patients treated with stereotactic body radiation therapy (SBRT), high intensity features embedded in dark surroundings may suggest a local failure (LF). We investigated image intensity histogram in imaging features to predict LF and local control (LC). Methods: Sixty-seven spinal tumors were treated with SBRT at our institution with scheduled follow-up MR T2-weighted (TR 3200–6600ms; TE 75-132ms) imaging. The LF group included 10 tumors with 8.7 months median follow-up, while the LC group had 11 tumors with 24.1 months median follow-up. The follow-up images were fused to the planning CT. Image intensity histograms of the GTV were calculated. Voxels in greater than 90% (V90), 80% (V80), and peak (Vpeak) of the histogram were grouped into sub-ROIs to determine the best feature histogram. The intensity of each sub-ROI was evaluated using the mean T2-weighted signal ratio (intensity in sub-ROI / intensity in normal vertebrae). An ROC curve in predicting LF for each sub-ROI was calculated to determine the best feature histogram parameter for LF prediction. Results: Mean T2-weighted signal ratio in the LF group was significantly higher than that in the LC group for all sub-ROIs (1.1±0.4 vs. 0.7±0.2, 1.2±0.4 vs. 0.8±0.2, 1.4±0.5 vs. 0.8±0.2, for V90, V80, and Vpeak, p=0.02, 0.02, and 0.002, respectively). The corresponding areas-under-curve (AUC) of ROC were 0.78, 0.80, and 0.87, p=0.02, 0.03, 0.004, respectively. No correlation was found between T2-weighted signal ratio in Vpeak and follow-up time (Pearson's ρ=0.15). Conclusion: Increased T2-weighted signal can be used to identify local failure while decreased signal indicates local control after spinal SBRT. By choosing the best histogram parameter (here the Vpeak), the AUC of the ROC can be substantially improved, which implies reliable prediction of LC and LF. These results are being further studied and validated with large multi-institutional data.

60 APPLIED LIFE SCIENCES↗

Investigating CT to CBCT image registration for head and neck proton therapy as a tool for daily dose recalculation

Purpose: Intensity modulated proton therapy (IMPT) of head and neck (H and N) cancer patients may be improved by plan adaptation. The decision to adapt the treatment plan based on a dose recalculation on the current anatomy requires a diagnostic quality computed tomography (CT) scan of the patient. As gantry-mounted cone beam CT (CBCT) scanners are currently being offered by vendors, they may offer daily or weekly updates of patient anatomy. CBCT image quality may not be sufficient for accurate proton dose calculation and it is likely necessary to perform CBCT CT number correction. In this work, the authors investigated deformable image registration (DIR) of the planning CT (pCT) to the CBCT to generate a virtual CT (vCT) to be used for proton dose recalculation. Methods: Datasets of six H and N cancer patients undergoing photon intensity modulated radiation therapy were used in this study to validate the vCT approach. Each dataset contained a CBCT acquired within 3 days of a replanning CT (rpCT), in addition to a pCT. The pCT and rpCT were delineated by a physician. A Morphons algorithm was employed in this work to perform DIR of the pCT to CBCT following a rigid registration of the two images. The contours from the pCT were deformed using the vector field resulting from DIR to yield a contoured vCT. The DIR accuracy was evaluated with a scale invariant feature transform (SIFT) algorithm comparing automatically identified matching features between vCT and CBCT. The rpCT was used as reference for evaluation of the vCT. The vCT and rpCT CT numbers were converted to stopping power ratio and the water equivalent thickness (WET) was calculated. IMPT dose distributions from treatment plans optimized on the pCT were recalculated with a Monte Carlo algorithm on the rpCT and vCT for comparison in terms of gamma index, dose volume histogram (DVH) statistics as well as proton range. The DIR generated contours on the vCT were compared to physician-drawn contours on the rpCT. Results: The DIR accuracy was better than 1.4 mm according to the SIFT evaluation. The mean WET differences between vCT (pCT) and rpCT were below 1 mm (2.6 mm). The amount of voxels passing 3%/3 mm gamma criteria were above 95% for the vCT vs rpCT. When using the rpCT contour set to derive DVH statistics from dose distributions calculated on the rpCT and vCT the differences, expressed in terms of 30 fractions of 2 Gy, were within [−4, 2 Gy] for parotid glands (D{sub mean}), spinal cord (D{sub 2%}), brainstem (D{sub 2%}), and CTV (D{sub 95%}). When using DIR generated contours for the vCT, those differences ranged within [−8, 11 Gy]. Conclusions: In this work, the authors generated CBCT based stopping power distributions using DIR of the pCT to a CBCT scan. DIR accuracy was below 1.4 mm as evaluated by the SIFT algorithm. Dose distributions calculated on the vCT agreed well to those calculated on the rpCT when using gamma index evaluation as well as DVH statistics based on the same contours. The use of DIR generated contours introduced variability in DVH statistics.

60 APPLIED LIFE SCIENCES↗

Development and evaluation of aperture-based complexity metrics using film and EPID measurements of static MLC openings

Purpose: Complexity metrics have been suggested as a complement to measurement-based quality assurance for intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT). However, these metrics have not yet been sufficiently validated. This study develops and evaluates new aperture-based complexity metrics in the context of static multileaf collimator (MLC) openings and compares them to previously published metrics. Methods: This study develops the converted aperture metric and the edge area metric. The converted aperture metric is based on small and irregular parts within the MLC opening that are quantified as measured distances between MLC leaves. The edge area metric is based on the relative size of the region around the edges defined by the MLC. Another metric suggested in this study is the circumference/area ratio. Earlier defined aperture-based complexity metrics—the modulation complexity score, the edge metric, the ratio monitor units (MU)/Gy, the aperture area, and the aperture irregularity—are compared to the newly proposed metrics. A set of small and irregular static MLC openings are created which simulate individual IMRT/VMAT control points of various complexities. These are measured with both an amorphous silicon electronic portal imaging device and EBT3 film. The differences between calculated and measured dose distributions are evaluated using a pixel-by-pixel comparison with two global dose difference criteria of 3% and 5%. The extent of the dose differences, expressed in terms of pass rate, is used as a measure of the complexity of the MLC openings and used for the evaluation of the metrics compared in this study. The different complexity scores are calculated for each created static MLC opening. The correlation between the calculated complexity scores and the extent of the dose differences (pass rate) are analyzed in scatter plots and using Pearson’s r-values. Results: The complexity scores calculated by the edge area metric, converted aperture metric, circumference/area ratio, edge metric, and MU/Gy ratio show good linear correlation to the complexity of the MLC openings, expressed as the 5% dose difference pass rate, with Pearson’s r-values of −0.94, −0.88, −0.84, −0.89, and −0.82, respectively. The overall trends for the 3% and 5% dose difference evaluations are similar. Conclusions: New complexity metrics are developed. The calculated scores correlate to the complexity of the created static MLC openings. The complexity of the MLC opening is dependent on the penumbra region relative to the area of the opening. The aperture-based complexity metrics that combined either the distances between the MLC leaves or the MLC opening circumference with the aperture area show the best correlation with the complexity of the static MLC openings.

60 APPLIED LIFE SCIENCES↗

SU-C-209-06: Improving X-Ray Imaging with Computer Vision and Augmented Reality

Purpose: To determine the feasibility of using a computer vision algorithm and augmented reality interface to reduce repeat rates and improve consistency of image quality and patient exposure in general radiography. Methods: A prototype device, designed for use with commercially available hardware (Microsoft Kinect 2.0) capable of depth sensing and high resolution/frame rate video, was mounted to the x-ray tube housing as part of a Philips DigitalDiagnost digital radiography room. Depth data and video was streamed to a Windows 10 PC. Proprietary software created an augmented reality interface where overlays displayed selectable information projected over real-time video of the patient. The information displayed prior to and during x-ray acquisition included: recognition and position of ordered body part, position of image receptor, thickness of anatomy, location of AEC cells, collimated x-ray field, degree of patient motion and suggested x-ray technique. Pre-clinical data was collected in a volunteer study to validate patient thickness measurements and x-ray images were not acquired. Results: Proprietary software correctly identified ordered body part, measured patient motion, and calculated thickness of anatomy. Pre-clinical data demonstrated accuracy and precision of body part thickness measurement when compared with other methods (e.g. laser measurement tool). Thickness measurements provided the basis for developing a database of thickness-based technique charts that can be automatically displayed to the technologist. Conclusion: The utilization of computer vision and commercial hardware to create an augmented reality view of the patient and imaging equipment has the potential to drastically improve the quality and safety of x-ray imaging by reducing repeats and optimizing technique based on patient thickness. Society of Pediatric Radiology Pilot Grant; Washington University Bear Cub Fund.

60 APPLIED LIFE SCIENCES↗

SU-F-J-06: Optimized Patient Inclusion for NaF PET Response-Based Biopsies

Purpose: A method to guide mid-treatment biopsies using quantitative [F-18]NaF PET/CT response is being investigated in a clinical trial. This study aims to develop methodology to identify patients amenable to mid-treatment biopsy based on pre-treatment imaging characteristics. Methods: 35 metastatic prostate cancer patients had NaF PET/CT scans taken prior to the start of treatment and 9–12 weeks into treatment. For mid-treatment biopsy targeting, lesions must be at least 1.5 cm{sup 3} and located in a clinically feasible region (lumbar/sacral spine, pelvis, humerus, or femur). Three methods were developed based on number of lesions present prior to treatment: a feasibility-restricted method, a location-restricted method, and an unrestricted method. The feasibility restricted method only utilizes information from lesions meeting biopsy requirements in the pre-treatment scan. The unrestricted method accounts for all lesions present in the pre-treatment scan. For each method, optimized classification cutoffs for candidate patients were determined. Results: 13 of the 35 patients had enough lesions at the mid-treatment for biopsy candidacy. Of 1749 lesions identified in all 35 patients at mid-treatment, only 9.8% were amenable to biopsy. Optimizing the feasibility-restricted method required 4 lesions at pre-treatment meeting volume and region requirements for biopsy, resulting patient identification sensitivity of 0.8 and specificity of 0.7. Of 6 false positive patients, only one patient lacked lesions for biopsy. Restricting for location alone showed poor results (sensitivity 0.2 and specificity 0.3). The optimized unrestricted method required patients have at least 37 lesions in pretreatment scan, resulting in a sensitivity of 0.8 and specificity of 0.8. There were 5 false positives, only one lacked lesions for biopsy. Conclusion: Incorporating the overall pre-treatment number of NaF PET/CT identified lesions provided best prediction for identifying candidate patients for mid-treatment biopsy. This study provides validity for prediction-based inclusion criteria that can be extended to various clinical trial scenarios. Funded by Prostate Cancer Foundation.

60 APPLIED LIFE SCIENCES↗

TH-CD-BRA-07: MRI-Linac Dosimetry: Parameters That Change in a Magnetic Field

Purpose: In MRI-linac integrated systems, the presence of the magnetic (B-)field has a large impact of the dose-distribution and the dose-responses of detectors; yet established protocols and previous experience may lead to assumptions about the commissioning process that are no longer valid. This study quantifies parameters that change when performing dosimetry with an MRI-linac including beam quality specifiers and the effective-point-of-measurement (EPOM) of ionization chambers. Methods: We used the Geant4 Monte Carlo code for this work with physics parameters that pass the Fano cavity test to within 0.1% for the simulated conditions with and without a 1.5 T B-field. A point source model with the energy distribution of an MRI-linac beam was used with and without the B-field to calculate the beam quality specifiers %dd(10)× and TPR{sup 20}{sub 10}, the variation of chamber response with orientation and the how the B-field affects the EPOM of ionization chambers by comparing depth-dose curves calculated in water to those generated by a model PTW30013 Farmer chamber. Results: The %dd(10)× changes by over 2% in the presence of the B-field while the TPR{sup 20}{sub 10} is unaffected. Ionization chamber dose-response is known to depend on the orientation w.r.t. the B-field, but two alternative perpendicular orientations (anti-parallel to each other) also differ in dose-response by over 1%. The B-field shifts the EPOM downstream (closer to the chamber center) but it is also shifted laterally by 0.27 times the chamber’s cavity radius. Conclusion: The EPOM is affected by the B-field and it even shifts laterally. The relationship between %dd(10)× and the Spencer-Attix stopping powers is also changed. Care must be taken when using chambers perpendicular to the field as the dose-response changes depending on which perpendicular orientation is used. All of these effects must be considered when performing dosimetry in B-fields and should be accounted for in future dosimetry protocols. This project was partially funded by Elekta Ltd.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Methodology to Compare Twitter Reaction Trends between Disinformation Communities, to COVID related Campaign Events at Different Geospatial Granularities

With still ongoing COVID pandemic, there is an immediate need for a deeper understanding of how Twitter discussions (or chatters) in disinformation spreading communities get triggered. More specifically, the value is in monitoring how such trigger events in Twitter discussion do align with the timelines of relevant influencing events in the society (indicated in this work as campaign events). For campaign events in regards to COVID pandemic, we consider both NPI (Nonpharmaceutical Interventions) campaigns and disinformation spreading campaigns together. In this short paper we have presented a novel methodology to quantify, compare and relate two Twitter disinformation communities, in terms of their reaction patterns to the timelines of major campaign events. We have also analyzed these campaigns at their three geospatial granularity contexts: local county, state, and country/ federal. We have conducted a novel dataset collection on campaigns (NPI + Disinformation) at these different geospatial granularities. Then, with collected dataset on Twitter disinformation communities, we have performed a case study to validate our proposed methodology.

De, Debraj↗

Polarized Deep-Inelastic Scattering with Spin Correlations in Herwig 7

This repository is the research software and reproducibility companion for the HerwigPol polarized deep-inelastic scattering implementation developed for Herwig 7. It brings together the modified Herwig and ThePEG source snapshots, the curated POLDIS fixed-order reference code, the custom Rivet analyses, the DIS validation workflow, and the paper source in a single formal repository layout. The repository is intended to preserve the source-level ingredients needed to rebuild and re-run the validated DIS studies. It therefore tracks code, input cards, workflow drivers, and technical notes, while intentionally excluding generated artifacts such as build products, campaign outputs, merged YODA files, plots, and rendered paper outputs.

Papaefstathioou, Andreas [Kennesaw State Universit↗

Efforts to enhance reproducibility in a human performance research project

Background: Ensuring the validity of results from funded programs is a critical concern for agencies that sponsor biological research. In recent years, the open science movement has sought to promote reproducibility by encouraging sharing not only of finished manuscripts but also of data and code supporting their findings. While these innovations have lent support to third-party efforts to replicate calculations underlying key results in the scientific literature, fields of inquiry where privacy considerations or other sensitivities preclude the broad distribution of raw data or analysis may require a more targeted approach to promote the quality of research output. Methods: We describe efforts oriented toward this goal that were implemented in one human performance research program, Measuring Biological Aptitude, organized by the Defense Advanced Research Project Agency's Biological Technologies Office. Our team implemented a four-pronged independent verification and validation (IV&V) strategy including 1) a centralized data storage and exchange platform, 2) quality assurance and quality control (QA/QC) of data collection, 3) test and evaluation of performer models, and 4) an archival software and data repository. Results: Our IV&V plan was carried out with assistance from both the funding agency and participating teams of researchers. QA/QC of data acquisition aided in process improvement and the flagging of experimental errors. Holdout validation set tests provided an independent gauge of model performance. Conclusions: In circumstances that do not support a fully open approach to scientific criticism, standing up independent teams to cross-check and validate the results generated by primary investigators can be an important tool to promote reproducibility of results.

59 BASIC BIOLOGICAL SCIENCES↗

EGS Collab Experiment 2: Microseismic Monitoring

This dataset contains continuous seismic waveform data recorded during stimulation and thermal circulation tests for the Enhanced Geothermal Systems (EGS) Collab Experiment #2, conducted from February to September 2022 at the Sanford Underground Research Facility in Lead, South Dakota. This experiment aimed to study and validate models of geothermal systems by injecting high-pressure fluids into rock formations 1200-1500 meters below the surface, inducing microseismic events. The seismic monitoring system included 16 three-component accelerometers and a 24-channel hydrophone array, installed in boreholes surrounding the test area. Data were recorded at high sampling rates using a continuous waveform recording system to monitor seismic activity in real time. The dataset contains the raw data stored in binary format, with files named based on timestamps, and includes calibration certificates for some sensors to facilitate corrections to real units. Users are strongly advised to consult the accompanying detailed report, which outlines the experimental setup, sensor specifications, installation procedures, and data processing methods. The report also describes important nuances, such as the hardware filters on hydrophones, sensor calibration details, and the naming conventions for the recorded data. Proper use of this dataset may require familiarity with seismic data analysis tools, such as the Obspy Python package, and an understanding of the SEED naming conventions used for channel identification.

15 GEOTHERMAL ENERGY↗

Validation of simulated wave energy converter responses to focused waves

Focused waves are increasingly used as a design method to predict extreme loads for offshore structures, such as wave energy converters (WECs). However, the ability of computational methods to accurately simulate the prescribed focused waves and resulting wave structure interactions is not well validated. This study uses two computational fluid dynamic methods, WEC-Sim and STAR-CCM+, to evaluate the responses of two taut-moored WEC-like buoys to three different focused waves. WEC-Sim is a computationally efficient, mid-fidelity model, based on linearised potential flow theory. In contrast, STAR-CCM+ is a high-fidelity, three-dimensional, unsteady, Reynolds-averaged Navier–Stokes-based model. The two buoy geometries considered are a hemispherical-bottom cylinder and a truncated cylinder with a cylindrical moon pool. Three prescribed focused waves are generated in both codes, and the simulated displacements and mooring loads are obtained for each of the hydrodynamic bodies. The resulting STAR-CCM+ generated focused waves have approximately the same accuracy, in comparison with the analytic solution, as experimentally generated focused waves. The WEC-Sim simulated responses, when using viscous coefficients tuned to the measured displacements, are, on average, within 11.5% of experimentally measured values, whereas the STAR-CCM+ simulated responses are, on average, within 14.2% of the experimental values.

16 TIDAL AND WAVE POWER↗

Radiation Robust RF Gas Beam Detector R&D for Intensity Frontier Experiments

A novel radiation robust RF gas beam detector has been demonstrated by using the Main Injector beam at Fermilab. The detector demonstrated a stable signal gain, fast response time, and high radiation resistivity with intense proton beams. The plasma process in the detector is studied to validate the plasma physics model. The result suggests that the detector is applicable for Long Baseline Neutrino Facility at Fermilab. To prepare for the LBNF, a proto type detector will be made and applied for the Neutrino at Main Injector target system. Progress of the project will be given in the presentation.

43 PARTICLE ACCELERATORS↗

Universal Injector at LERF – Baseline Design

A new electron injector complex has been proposed within the Low Energy Recirculating Facility (LERF) vault, which would serve both the 22 GeV CEBAF and the positron programs, while being compatible with the electron source required to produce positrons for Ce+BAF. The baseline design of a 3-pass recirculator features a main linac configured with three cryomodules, five isochronous arcs and three straight sections, allowing electron beam acceleration up to 650 MeV. The injector offers the flexibility to extract 1-pass and 2-pass energy electrons, as needed for positron production, with final reconfiguration to a 3-pass 650 MeV injector for 22 GeV CEBAF. This paper provides an overview of the baseline design of the Universal injector complex, including the 8 MeV injector and the recirculator. A comprehensive suite of beam dynamics studies to validate our design is being launched, starting with start-to-end tracking with Elegant followed by the orbit correction and error mitigation.

Bogacz, A. [Thomas Jefferson National Accelerator ↗

Study of Mechanisms of Aerosol Indirect Effects on Glaciated Clouds: Progress during the Project (Final Technical Report)

This 3-year project has studied how aerosol pollution influences glaciated clouds. The tool applied has been an 'aerosol-cloud model'. It is a type of Cloud-System Resolving Model (CSRM) modified to include 2-moment bulk microphysics and 7 aerosol species, as described by Phillips et al. (2009, 2013). The study has been done by, first, improving the model and then performing sensitivity studies with validated simulations of a couple of observed cases from ARM. These are namely the Tropical Warm Pool International Cloud Experiment (TWP-ICE) over the tropical west Pacific and the Cloud and Land Surface Interaction Campaign (CLASIC) over Oklahoma. During the project, sensitivity tests with the model showed that in continental clouds, extra liquid aerosols (soluble aerosol material) from pollution inhibited warm rain processes for precipitation production. This promoted homogeneous freezing of cloud droplets and aerosols. Mass and number concentrations of cloud-ice particles were boosted. The mean sizes of cloud-ice particles were reduced by the pollution. Hence, the lifetime of glaciated clouds, especially ice-only clouds, was augmented due to inhibition of sedimentation and ice-ice aggregation. Latent heat released from extra homogeneous freezing invigorated convective updrafts, and raised their maximum cloud-tops, when aerosol pollution was included. In the particular cases simulated in the project, the aerosol indirect effect of glaciated clouds was twice than of (warm) water clouds. This was because glaciated clouds are higher in the troposphere than water clouds and have the first interaction with incoming solar radiation. Ice-only clouds caused solar cooling by becoming more extensive as a result of aerosol pollution. This 'lifetime indirect effect' of ice-only clouds was due to higher numbers of homogeneously nucleated ice crystals causing a reduction in their mean size, slowing the ice-crystal process of snow production and slowing sedimentation. In addition to the known indirect effects (glaciation, riming and thermodynamic), new indirect effects were discovered and quantified due to responses of sedimentation, aggregation and coalescence in glaciated clouds to changing aerosol conditions. In summary, the change in horizontal extent of the glaciated clouds ('lifetime indirect effects'), especially of ice-only clouds, was seen to be of higher importance in regulating aerosol indirect effects than changes in cloud properties ('cloud albedo indirect effects').

54 ENVIRONMENTAL SCIENCES↗

Study of Mechanisms of Aerosol Indirect Effects on Glaciated Clouds: Progress during the Project (Final Technical Report)

This 3-year project has studied how aerosol pollution influences glaciated clouds. The tool applied has been an 'aerosol-cloud model'. It is a type of Cloud-System Resolving Model (CSRM) modified to include 2-moment bulk microphysics and 7 aerosol species, as described by Phillips et al. (2009, 2013). The study has been done by, first, improving the model and then performing sensitivity studies with validated simulations of a couple of observed cases from ARM. These are namely the Tropical Warm Pool International Cloud Experiment (TWP-ICE) over the tropical west Pacific and the Cloud and Land Surface Interaction Campaign (CLASIC) over Oklahoma. During the project, sensitivity tests with the model showed that in continental clouds, extra liquid aerosols (soluble aerosol material) from pollution inhibited warm rain processes for precipitation production. This promoted homogeneous freezing of cloud droplets and aerosols. Mass and number concentrations of cloud-ice particles were boosted. The mean sizes of cloud-ice particles were reduced by the pollution. Hence, the lifetime of glaciated clouds, especially ice-only clouds, was augmented due to inhibition of sedimentation and ice-ice aggregation. Latent heat released from extra homogeneous freezing invigorated convective updrafts, and raised their maximum cloud-tops, when aerosol pollution was included. In the particular cases simulated in the project, the aerosol indirect effect of glaciated clouds was twice than of (warm) water clouds. This was because glaciated clouds are higher in the troposphere than water clouds and have the first interaction with incoming solar radiation. Ice-only clouds caused solar cooling by becoming more extensive as a result of aerosol pollution. This 'lifetime indirect effect' of ice-only clouds was due to higher numbers of homogeneously nucleated ice crystals causing a reduction in their mean size, slowing the ice-crystal process of snow production and slowing sedimentation. In addition to the known indirect effects (glaciation, riming and thermodynamic), new indirect effects were discovered and quantified due to responses of sedimentation, aggregation and coalescence in glaciated clouds to changing aerosol conditions. In summary, the change in horizontal extent of the glaciated clouds ('lifetime indirect effects'), especially of ice-only clouds, was seen to be of higher importance in regulating aerosol indirect effects than changes in cloud properties ('cloud albedo indirect effects').

54 ENVIRONMENTAL SCIENCES↗

Upscaling of U(VI) Desorption and Transport Using Decimeter-Scale Tanks

Experimental work was used to validate modeling studies and develop multicontinuum models of U(VI) transport in a contaminated aquifer. At the bench scale, it has been shown that U(VI) desorption is rate-limited and that rates are dependent on the bicarbonate concentration. Two decimeter-scale experiments were conducted in order to help establish rigorous upscaling approaches that could be tested at the tracer test and plume scales.

58 GEOSCIENCES↗

Design and Testing of CO 2 Compression Using Supersonic Shock Wave Technology

This report summarizes work performed by Ramgen and subcontractors in pursuit of the design and construction of a 10 MW supersonic CO2 compressor and supporting facility. The compressor will demonstrate application of Ramgen’s supersonic compression technology at an industrial scale using CO2 in a closed-loop. The report includes details of early feasibility studies, CFD validation and comparison to experimental data, static test experimental results, compressor and facility design and analyses, and development of aerodynamic tools. A summary of Ramgen's ISC Engine program activity is also included. This program will demonstrate the adaptation of Ramgen's supersonic compression and advanced vortex combustion technology to result in a highly efficient and cost effective alternative to traditional gas turbine engines. The build out of a 1.5 MW test facility to support the engine and associated subcomponent test program is summarized.

42 ENGINEERING↗

‘Universal Injector’ at LERF - Layout and Optics Architecture

Here, we present a next level design of a compact injector within the LERF vault, which would serve both the 22 GeV CEBAF and the positron program, while being compatible with the electron source required to produce positrons for Ce+BAF. The baseline design of a 3-pass recirculator features a main linac configured with three C-75 cryo-modules, five isochronous return arcs and three straight sections, facilitating electron beam acceleration up to 650 MeV. The Universal Injector offers flexibility of extraction 1-pass and 2-pass energy electrons, as needed for positron production, with a final 3-pass extraction required by the 650 MeV injector for 22 GeV CEBAF. This note provides an overview of the baseline optics design of the Universal Injector complex, including the 8 MeV injector merger and the recirculator racetrack, including individual extraction lines for all three passes. A comprehensive suite of beam dynamics studies to validate the design is under way; starting with the orbit correction scheme, followed by start-to-end tracking with lattice misalignments and magnet errors.

Bogacz, Alex [Thomas Jefferson National Accelerato↗