Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VOLUME”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Tracer techniques for urine volume determination and urine collection and sampling back-up system

The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.

Ramirez, R. V.↗

A study to determine the flight characteristics and handling qualities of variable geometry spacecraft. Volume 2: Medium L/D concept with switch-blade wings

Flight characteristics and wing deployment transients for a variable geometry logistics spacecraft concept having a hypersonic lift-drag ratio near 2.0, and employing switch-blade wings for deployment at high subsonic speeds have been determined. These characteristics are based on detailed static wind tunnel results and estimated weight and inertial characteristics of a 9-man logistics lifting entry vehicle. In all instances, unpowered flight is assumed. The present volume is the second of a four volume series encompassing hypersonic lift-drag ratio vehicles from 1 to 3, and including several forms of deployable lifting surfaces. For Volumes 1 and 3, see N70-25699 and N72-15779 respectively.

Kuchta, B. J.↗

Effects of additives on volume change on melting, surface tension, and viscosity of liquid aluminum oxide

The effects of various oxide additives on the volume change on melting, the surface tension, and the viscosity of liquid Al2O3 were studied. Additives of Sm2O3, MgO, and Y2O3 which form solid solutions, compounds, and multiphase solids with Al2O3 were studied. A review of the property data for Al2O3 and Al2O3 containing oxide additives is presented. Oxide additives to Al2O3 reduce the volume change on melting and with the exception of SiO2 lower the viscosity; surface tensions change with oxide additives, but changes vary with different container material. Viscosity and volume change on melting appeared to be significantly more important for studying the properties of liquid oxides than surface tension. Supercooling of 270 K of yttrium aluminum garnet was observed.

Bates, J. L.↗

Red cell volume with changes in plasma osmolarity during maximal exercise.

The volume of the red cell in vivo was measured during acute changes in plasma osmolarity evoked through short (6 to 8 min) maximal exercise in six male volunteer subjects. Simultaneous measurements of mean corpuscular red cell volume (MCV), hematocrit, blood hemoglobin, mean corpuscular hemoglobin concentration (MCHC), and plasma osmolarity showed that there was no change in the MCV or MCHC with a concomitant rise of nearly 6% in plasma osmolarity. Apparently, in vivo, the volume of the red cell in exercising healthy human subjects does not change measurably, in spite of significant changes in osmotic pressure of the surrounding medium. Consequently, it is not justified to correct postexercise hematocrit measurements for changes in plasma osmolarity.

Van Beaumont, W.↗

Development of a prototype fluid volume measurement system

The research is reported in applying the axial fluid temperature differential flowmeter to a urine volume measurement system for space missions. The fluid volume measurement system is described along with the prototype equipment package. Flowmeter calibration, electronic signal processing, and typical void volume measurements are also described.

Poppendiek, H. F.↗

Evaluation of some control-volume techniques for analysis of shock-boundary layer interactions in supersonic inlets

Various control-volume models used to analyze the shock boundary layer bleed interaction were investigated. The bleed assumptions of the models and their influence on the analytical solutions are discussed. The results of the analysis using these models are compared with experimental boundary-layer data taken in a supersonic inlet. The experimental Mach number upstream of the interaction was 1.66, and the oblique-shock pressure ratio was 1.33. The boundary layer data included bleed flow rates up to approximately 0.6 of the upstream boundary layer mass flow rate. The first model assumed the bleed was removed from the control volume with a momentum that was characterized by a pressure intermediate between the upstream and downstream pressures. The second model assumed the control volume was bounded by a streamline dividing the bleed and residual flows and eliminated the need to specify the momentum of the bleed flow. Comparison of the results using the models showed that specifying the bleed pressure in one model was equivalent to specifying the pressure along the dividing streamline in the other.

Hingst, W. R.↗

Response of local vascular volumes to lower body negative pressure stress

The present study involved an intravenous injection of radioactive iodinated serum albumin, equilibration of this isotope within the vascular space, and the continuous measurement of isotope activity over selected anatomical areas before, during and following multiple human LBNP tests. Both rate and magnitude of vascular pooling were distinctly different within each of five selected lower body anatomical areas. In the upper body, all areas except the abdomen showed depletions from their resting vascular volumes during LBNP. The presence of uniquely different pooling patterns in the lower body, the apparent stability of abdominal vascular volumes, and a possible decrease in cerebral blood volume during LBNP represent the major findings of this study.

Wolthuis, R. A.↗

Computer program system for dynamic simulation and stability analysis of passive and actively controlled spacecraft. Volume 1. Theory

A theoretical development and associated digital computer program system is presented. The dynamic system (spacecraft) is modeled as an assembly of rigid and/or flexible bodies not necessarily in a topological tree configuration. The computer program system may be used to investigate total system dynamic characteristics including interaction effects between rigid and/or flexible bodies, control systems, and a wide range of environmental loadings. Additionally, the program system may be used for design of attitude control systems and for evaluation of total dynamic system performance including time domain response and frequency domain stability analyses. Volume 1 presents the theoretical developments including a description of the physical system, the equations of dynamic equilibrium, discussion of kinematics and system topology, a complete treatment of momentum wheel coupling, and a discussion of gravity gradient and environmental effects. Volume 2, is a program users' guide and includes a description of the overall digital program code, individual subroutines and a description of required program input and generated program output. Volume 3 presents the results of selected demonstration problems that illustrate all program system capabilities.

Bodley, C. S.↗

Astronautic Structures Manual, Volume 3

This document (Volumes I, II, and III) presents a compilation of industry-wide methods in aerospace strength analysis that can be carried out by hand, that are general enough in scope to cover most structures encountered, and that are sophisticated enough to give accurate estimates of the actual strength expected. It provides analysis techniques for the elastic and inelastic stress ranges. It serves not only as a catalog of methods not usually available, but also as a reference source for the background of the methods themselves. An overview of the manual is as follows: Section A is a general introduction of methods used and includes sections on loads, combined stresses, and interaction curves; Section B is devoted to methods of strength analysis; Section C is devoted to the topic of structural stability; Section D is on thermal stresses; Section E is on fatigue and fracture mechanics; Section F is on composites; Section G is on rotating machinery; and Section H is on statistics. These three volumes supersede Volumes I and II, NASA TM X-60041 and NASA TM X-60042, respectively.

Source record↗

Variable volume maser techniques

The frequency stability of hydrogen masers in variable volume storage bulbs is discussed in terms of wall shift. Variable volume devices discussed include: Brenner flexible bulb, Debely device, and the concertina hydrogen maser. A flexible cone variable volume element outside the cavity is described.

Reinhardt, V. S.↗

Fractional watt Vuillemier cryogenic refrigerator program engineering notebook. Volume 1: Thermal analysis

The cryogenic refrigerator thermal design calculations establish design approach and basic sizing of the machine's elements. After the basic design is defined, effort concentrates on matching the thermodynamic design with that of the heat transfer devices (heat exchangers and regenerators). Typically, the heat transfer device configurations and volumes are adjusted to improve their heat transfer and pressure drop characteristics. These adjustments imply that changes be made to the active displaced volumes, compensating for the influence of the heat transfer devices on the thermodynamic processes of the working fluid. Then, once the active volumes are changed, the heat transfer devices require adjustment to account for the variations in flows, pressure levels, and heat loads. This iterative process is continued until the thermodynamic cycle parameters match the design of the heat transfer devices. By examing several matched designs, a near-optimum refrigerator is selected.

Miller, W. S.↗

REXOR 2 rotorcraft simulation model. Volume 1: Engineering documentation

A rotorcraft nonlinear simulation called REXOR II, divided into three volumes, is described. The first volume is a development of rotorcraft mechanics and aerodynamics. The second is a development and explanation of the computer code required to implement the equations of motion. The third volume is a user's manual, and contains a description of code input/output as well as operating instructions.

Reaser, J. S.↗

Geosynchronous Microwave Atmospheric Sounding Radiometer (MASR) feasibility studies. Volume 1: Management summary

The mission of the microwave atmospheric sounding radiometer (MASR) is to collect data to aid in the observation and prediction of severe storms. The geosynchronous orbit allows the continuous atmospheric measurement needed to resolve mesoscale dynamics. The instrument may operate in conjunction with this document, Volume 1 - Management, which summarizes the highlights of final reports on both the radiometer instrument and antenna studies. The radiometer instrument summary includes a synopsis of Volume 2 - Radiometer Receiver Feasibility, including design, recommended configuration, performance estimates, and weight and power estimates. The summary of the antenna study includes a synopsis of Volume 3 - Antenna Feasibility, including preliminary design tradeoffs, performance of selected design, and details of the mechanical/thermal design.

Source record↗

The capability of satellite borne remote sensors to measure stratospheric trace constituents. Volume 1: Background and requirements

Volume 1 of a three volume report issued as MITRE/METREX Technical Report is presented. This volume contains a synthesis of the results of two previous MITRE/METREX studies and an update of the information. These studies deal with a comprehensive review of stratospheric trace constituent measurement requirements. The scope of the study was restricted to those contituents which fall into the general category of air pollutants.

Keitz, E. L.↗