Structural Design Methods and Materials Testing for Hydrogen Components.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Anemometer readings alone cannot provide a complete picture of air flow patterns at an open gloveport. Having a means to visualize air flow for field tests in general provides greater insight by indicating direction in addition to the magnitude of the air flow velocities in the region of interest. Furthermore, flow visualization is essential for Computational Fluid Dynamics (CFD) verification, where important modeling assumptions play a significant role in analyzing the chaotic nature of low-velocity air flow. A good example is shown Figure 1, where an unexpected vortex pattern occurred during a field test that could not have been measured relying only on anemometer readings. Here by, observing and measuring the patterns of the smoke flowing into the gloveport allowed the CFD model to be appropriately updated to match the actual flow velocities in both magnitude and direction.
Abstract not provided.
Abstract not provided.
One reason to use optical fibers to transmit data is for isolation from unintended electrical energy. Using fiber optics in an application where the fiber cable/system penetrates the aperture of a grounded enclosure serves two purposes: first, it allows for control signals to be transmitted where they are required, and second, the insulating properties of the fiber system help to electrically isolate the fiber terminations on the inside of the grounded enclosure. A fundamental question is whether fiber optic cables can allow electrical energy to pass through a grounded enclosure, with a lightning strike representing an extreme but very important case. A DC test bed capable of producing voltages up to 200 kV was used to characterize electrical properties of a variety of fiber optic cable samples. Leakage current in the samples were measured with a micro-Ammeter. In addition to the leakage current measurements, samples were also tested to DC voltage breakdown. After the fiber optic cables samples were tested with DC methods, they were tested under representative lightning conditions at the Sandia Lightning Simulator (SLS). Simulated lightning currents of 30 kA and 200 kA were selected for this test series. This paper documents measurement methods and test results for DC high voltage and simulated lightning tests performed at the Sandia Lightning Simulator on fiber optic cables. The tests performed at the SLS evaluated whether electrical energy can be conducted inside or along the surface of a fiber optic cable into a grounded enclosure under representative lightning conditions.
Different statistical methods are used in various fields to qualify processes and products, especially in emerging technologies like Additive Manufacturing (AM) or 3D printing. Since several statistical methods are being employed to ensure quality production of the 3D-printed parts, an overview of these methods used in 3D printing for different purposes is presented in this paper. The advantages and challenges, to understanding the importance it brings for design and testing optimization of 3D-printed parts are also discussed. The application of different metrology methods is also summarized to guide future researchers in producing dimensionally-accurate and good-quality 3D-printed parts. Here, this review paper shows that the Taguchi Methodology is the commonly-used statistical tool in optimizing mechanical properties of the 3D-printed parts, followed by Weibull Analysis and Factorial Design. In addition, key areas such as Artificial Intelligence (AI), Machine Learning (ML), Finite Element Analysis (FEA), and Simulation require more research for improved 3D-printed part qualities for specific purposes. Future perspectives are also discussed, including other methods that can help further improve the overall quality of the 3D printing process from designing to manufacturing.
A portable, case-enclosed pressure test manifold, configured to support both pneumatic and hydrostatic pressure testing, and comprising a downstream fluid path (e.g., a system test gauge, a ball valve, a system test port, a system relief valve, and other components/piping) and an upstream fluid path (e.g., a low-pressure gauge, a high-pressure gauge, and other components/piping). A regulator and/or the ball valve selectively operate the downstream fluid path, defining a hydrostatic pressure testing path, to receive a liquid; and the upstream fluid path in combination with the downstream fluid path, defining a pneumatic pressure testing path, to receive a gas. Manifold components are pressure rated based on use and are ASME Code B31.3 compliant. A flexible hose connects with either of the pneumatic pressure testing path and the hydrostatic pressure testing path of the manifold. The case includes parking receptables and a carrying handle configured to stow the hose during transport.
The prediction of the geothermal system efficiency is strong linked to the character of the flow system that connects injector and producer wells. If water flow develops channels or “short circuiting” between injection and extraction wells thermal sweep is poor and much of the reservoir is left untapped. The purpose of this project was to understand how channelized flow develops in fracture geothermal reservoirs and how it can be measured in the field. We explored two methods of assessing channelization: hydraulic connectivity tests and tracer tests. These methods were tested at a field site using two verification methods: ground penetrating radar (GPR) images of saline tracer and heat transfer measurements using distributed temperature sensing (DTS). The field site for these studies was the Altona Flat Fractured Rock Research Site located in northeastern New York State. Altona Flat Rock is an experimental site considered a geologic analog for some geothermal reservoirs given its low matrix porosity. Because soil overburden is thin, it provided unique access to saturated bedrock fractures and the ability image using GPR which does not effectively penetrate most soils. Five boreholes were drilled in a “five spot” pattern covering 100 m2 and hydraulically isolated in a single bedding plane fracture. This simple system allowed a complete characterization of the fracture. Nine small diameter boreholes were drilled from the surface to just above the fracture to allow the measurement of heat transfer between the fracture and the rock matrix. The focus of the hydraulic investigation was periodic hydraulic testing. In such tests, rather than pumping or injection in a well at a constant rate, flow is varied to produce an oscillating pressure signal. This pressure signal is sensed in other wells and the attenuation and phase lag between the source and receptor is an indication of hydraulic connection. We found that these tests were much more effective than constant pumping tests in identifying a poorly connected well. As a result, we were able to predict which well pairs would demonstrate channelized flow. The focus of the tracer investigation was multi-ionic tests. In multi-ionic tests several ionic tracers are injected simultaneously and the detected in a nearby pumping well. The time history of concentration, or breakthrough curve, will show a separation of the tracers. Anionic tracers travel with the water but cationic tracer undergo chemical exchange with cations on the surface of the rock. The degree of separation is indicative of the surface area exposed to the tracer. Consequently, flow channelization will tend to decrease the separation in the breakthrough. Estimation of specific surface area (the ration of fracture surface area to formation volume) is performed through matching the breakthrough curve with a transport model. We found that the tracer estimates of surface area were confirmed the prediction of channelized flow between well pairs produced by the periodic hydraulic tests. To confirm that the hydraulic and tracer tests were correctly predicting channelize flow, we imaged the flow field using surface GPR. Saline water was injected between the well pairs which produced a change in the amplitude and phase of the reflected radar signal. A map was produced of the migration of saline tracer from these tests which qualitatively confirmed the flow channelization predicted by the hydraulic and tracer tests. The resolution of the GPR was insufficient to quantitatively estimate swept surface area, however. Surface GPR is not applicable in typical geothermal fields because the penetration depths do not exceed 10’s of meters. Nevertheless, the method of using of phase to measure electrical conductivity and the assessment of antennae polarization represent a significant advancement in the field of surface GPR. The effect of flow character on fracture / rock thermal exchange was evaluated using heated water as a tracer. Water elevated 30 degrees C above the formation water was circulated between two wells pairs. One well pair had been identified in hydraulic and tracer testing as well connected and the other poorly connected. Temperature rise was measured in the adjacent rock matrix using coiled fiber optic cable interrogated for temperature using a DTS. This experimental design produced over 4000 temperature measurements every hour. We found that heat transfer between the fracture and the rock matrix was highly impacted by the character of the flow field. The strongly connected wells which had demonstrated flow channelization produced heat rise in a much more limited area than the more poorly connected wells. In addition, the heat increase followed the natural permeability of the fracture rather than the induced flow field. The primary findings of this work are (1) even in a single relatively planar fracture, the flow field can be highly heterogeneous and exhibit flow channeling, (2) channeling results from a combination of fracture permeability structure and the induced flow field, and (3) flow channeling leads to reduced heat transfer. Multi-ionic tracers effectively estimate relative surface area but an estimate of ion-exchange coefficients are necessary to provide an absolute measure of specific surface area. Periodic hydraulic tests also proved a relative indicator of connectivity but cannot prove an absolute measure of specific surface area.
The sixth blind test of organic crystal structure prediction (CSP) methods has been held, with five target systems: a small nearly rigid molecule, a polymorphic former drug candidate, a chloride salt hydrate, a co-crystal and a bulky flexible molecule. This blind test has seen substantial growth in the number of participants, with the broad range of prediction methods giving a unique insight into the state of the art in the field. Significant progress has been seen in treating flexible molecules, usage of hierarchical approaches to ranking structures, the application of density-functional approximations, and the establishment of new workflows and `best practices' for performing CSP calculations. All of the targets, apart from a single potentially disordered Z ' = 2 polymorph of the drug candidate, were predicted by at least one submission. Despite many remaining challenges, it is clear that CSP methods are becoming more applicable to a wider range of real systems, including salts, hydrates and larger flexible molecules. The results also highlight the potential for CSP calculations to complement and augment experimental studies of organic solid forms.
Digitalization of the instrumentation and control systems in nuclear power plant entails some new features which do not exist in analog systems. When the new features are applied in safety critical systems, the risk stemming from them should be quantified properly to assure the reliability of the entire power plant. Among the new features, software is considered as the most important factor because it can cause common cause failure to many redundant systems. Therefore, in this work, a test based reliability assessment method for a safety-critical software is developed. An output of a software is determined by not only inputs but also the internal state of the software at the time. In the case of safety critical software developed for usage in nuclear power plant, it is possible to directly investigate probable internal states thanks to detailed design specification and programing features, and the probable inputs also can be identified based on the physical linearity of each process parameter and hardware characteristics related to data acquisition. In this work, a development method for practical exhaustive test case consisting of investigation of internal state and probable input sets to a specific internal state are suggested. In addition to this, software logic simulator for execution of software logic test and the reliability quantification method based on the test result are developed. The feasibility of the suggested method is demonstrated via a case study. (authors)
We propose a new frequency-domain-based algorithm for detecting small-magnitude seismic events using dense surface seismic arrays. Our proposed method takes advantage of the high energy carried by S waves, and approximate known source locations, which are used to rotate the horizontal components to obtain the maximum amplitude. By surrounding the known source area with surface geophones, we achieve a favorable geometry for locating the detected seismic events with the backprojection method. To test our new detection method, we used a dense circular array, consisting of 151 5 Hz three-component geophones, over a 5 km aperture that was in operation at the Utah Frontier Observatory for Research in Geothermal Energy (FORGE) in southcentral Utah. We apply the new detection method during a small-scale test injection phase at FORGE, and during an aftershock sequence of an Mw 4.1 earthquake located ~30 km north of the geophone array, within the Black Rock volcanic field. We are able to detect and locate microseismic events (Mw<0) during injections, despite the high level of anthropogenic activity, and several aftershocks that are missing from the regional catalog. By comparing our method with known algorithms that operate both in the time and frequency domain, we show that our proposed method performs better in the case of the FORGE injection monitoring, and equally well for the off-array aftershock sequence. Our new method has the potential to improve microseismic event detections even in extremely noisy environments, and the proposed location scheme serves as a direct discriminant between true and false detections.
Cementitious waste forms offer a low temperature, cost effective technology for the solidification of liquid wastes. At the Department of Energy Hanford Site, 99-Tc and 129-I are radionuclides contained within low activity waste (LAW) which contribute significantly to environmental impacts associated with clean-up of the site. Cast Stone, a cementitious waste form comprised of 47 wt% blast furnace slag, 45 wt% fly ash and 8 wt% ordinary Portland cement, has undergone investigation as a possible candidate technology for the solidification of LAW. In screening tests using EPA Method 1315 leach testing of various mixes of Cast Stone with simulated LAW, Tc observed effective diffusivities (Dobs) had an average of 5.3 x 10-11 cm{sup 2}/s and I Dobs had an average of 5.7 x 10-9 cm{sup 2}/s. From these measurements, an opportunity exists to improve retention of Tc and I by Cast Stone. One approach to accomplish this is through the incorporation of Tc and I getters to selectively sequester Tc and I in the waste stream and eventual waste form. Initial testing conducted at PNNL identified potassium metal sulfide (KMS-2) and Sn(II)-apatite (Sn-A) as the strongest performing Tc getters and silver exchanged zeolite (Ag-Z) as the top performing I getter. This research also demonstrated that the Tc and I getters, when added to solution simultaneously, can have deleterious interactions with one another and lower the Tc and I removal levels. However, these interactions can be overcome through sequential treatment of solution with the getters. Cast Stone samples were fabricated using a 6.5 M Na average LAW simulant spiked with Tc and I with the addition of various combinations of Tc and I getters. Through EPA Method 1315 and Method 1313 testing it was found that the KMS-2 Tc getter was most successful at lowering Tc Dobs. The I getters were not effective, as apparent interference from sulfide components of the waste form may have led to dissociation of the AgI formed by the Ag-Z getter in sequestering the I from solution. (authors)
Development of analysis techniques for neutron imaging at the National Ignition Facility is an important and difficult task for the detailed understanding of high-neutron yield inertial confinement fusion implosions. Once developed, these methods must provide accurate images of the hot and cold fuels so that information about the implosion, such as symmetry and areal density, can be extracted. One method under development involves the numerical inversion of the pinhole image using knowledge of neutron transport through the pinhole aperture from Monte Carlo simulations. In this article we present results of source reconstructions based on simulated images that test the methods effectiveness with regard to pinhole misalignment.
Reactor protection system (RPS) in nuclear power plant (NPP) is in the process of digitalization in response to advanced features of digital systems. In this context, software integrity in the RPS becomes an important issue since it may cause common-cause failure. Therefore, to guarantee the safety of NPPs, the integrity of the software need to be properly demonstrated or assessed. There are three typical approaches for software reliability quantification: software reliability growth model (SRGM), Bayesian belief network (BBN), and test-based method. Basically, SRGM is difficult to apply to the safety-critical software because not only sufficient failure sets are unavailable but consequence of system failure is also unacceptable. Then the result obtained through the BBN model may have large uncertainty, so it produces difficulties in integrity demonstration of safety-critical software. Thus, the BBN result need to be complemented or verified by test-based method. Currently, for the integrity demonstration of safety-critical software, black-box test which feeds inputs and examines just outputs whether they succeeded or failed is considered based on trajectory-form-of-input (a series of successive values for the input variables that occur during the operation of the software over time). Usually these trajectory-inputs are randomly sampled from operational profile. In this approach, however, there are some practical difficulties. Therefore, we proposed a new test method for safety-critical software in digitalized reactor protection system (DRPS). The main contents described in this paper are about basic concepts under development of finite-test-cases by which the integrity of the software logic can be verified. It should be noted that the influence of the environments, such as operating system and other hardware, are not considered since the method focuses on software logic only. (authors)
A novel method to determine the fiber-matrix interfacial properties of ceramic matrix composites is proposed and evaluated; where micro- pillar samples containing inclined fiber/matrix interfaces were prepared from a SiC fiber reinforced SiC matrix composites then compression-tested using the nano-indentation technique. This new test method employs a simple geometry and mitigates the uncertainties associated with complex stress state in the conventional single filament push-out method for the determination of interfacial properties. Based on the test results using samples with different interface orientations , the interfacial debond shear strength and the internal friction coefficient are explicitly determined and compared with values obtained by other test methods.
A method and system for the monitoring and control of electrochemical cell degradation by use of strain-based battery testing. Strain-based battery is employed to recognize and implement a battery revival cycle to reduce battery degradation rates.
The test of eruption time prediction is an effort to prepare volcanic disaster mitigation, especially in the volcano’s inhabited slope area, such as Merapi Volcano. The test can be conducted by observing the increase of volcanic activity, such as seismicity degree, deformation and SO2 gas emission. One of methods that can be used to predict the time of eruption is Materials Failure Forecast Method (FFM). Materials Failure Forecast Method (FFM) is a predictive method to determine the time of volcanic eruption which was introduced by Voight (1988). This method requires an increase in the rate of change, or acceleration of the observed volcanic activity parameters. The parameter used in this study is the seismic energy value of Merapi Volcano from 1990 – 2012. The data was plotted in form of graphs of seismic energy rate inverse versus time with FFM graphical technique approach uses simple linear regression. The data quality control used to increase the time precision employs the data correlation coefficient value of the seismic energy rate inverse versus time. From the results of graph analysis, the precision of prediction time toward the real time of eruption vary between −2.86 up to 5.49 days.