Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Temperature Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Accelerated Synthesis of Ordered Mesoporous Carbons Using Plasma

Conventional ordered mesoporous carbon (OMC) production usually requires long processing times in the carbonization step to achieve desired temperatures through controlled ramps. To enable expedited materials discovery, developing advanced manufacturing capability with significantly improved throughput is highly desired. Current approaches for accelerating the synthesis of OMCs include using microwave and Joule heating. However, both methods rely on the introduction of additional components, such as microwave absorbers and electrically conductive agents, within the bulk materials to impart the ability to reach high carbonization temperatures. This work demonstrates accelerated synthesis and functionalization of OMCs through the use of a dielectric barrier discharge plasma, where carbonization can be accomplished within 15 min using 30 W plasma sources, representing more than an order of magnitude increase in polymer-to-carbon conversion kinetics compared to that of a traditionally pyrolyzed analogue. Particularly, the ability of performing rapid carbonization without the use of additional substrates within the OMC precursor systems is advantageous. A systematic investigation of how plasma power, time, and gas atmosphere impact the resulting OMC pore textures and properties is performed, demonstrating the broad applicability of plasma-enabled carbonization methods. Furthermore, we demonstrate that the plasma treatment strategy can be extended to incorporate heteroatoms into the carbon framework by introducing ammonia gas, resulting in OMCs with a nitrogen content up to 4.7 at %, as well as non-Pluronic templating systems for synthesizing OMC with pore sizes larger than 10 nm. As employing a plasma source for materials pyrolysis is an industrially relevant approach, our system can be extended toward scaled synthesis of OMCs with much faster production rates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-267: Development of the Compact Graphite Calorimetry System for the High Energy Photon Beam

Purpose: Graphite calorimeter systems are used for the absolute photon dosimetry. But many electronics are demanded in order to measure the tiny temperature changes. Minimizing the control system is needed to make a portable graphite calorimeter. Methods: A Domen-type graphite calorimetry system is constructing to measure the absorbed dose of the high energy photon beam. The graphite calorimeter divided into three parts, Core, Jacket, and Shield. In order to measure the temperature rising of the core due to the radiation accurately, the temperatures of the jacket and the shield should be controlled properly. A commercial temperature controller (Model 350, Lake Shore Cryogenics) was used to minimize the size of control system for making a portable graphite calorimetry system at the cost of the measurement uncertainty. The PID control of the jacket is conducted by the software (LabView) and Model 350 maintain the temperature of shield. Results: Our design value of the heat deposition power in the core is 0.04 mW for the dose rate of 3 Gy/min where the temperature sensitivity of the graphite is 1.4 mK/Gy. While the residuals of the Steinhart-hart equation fitting for the core thermistor were less than 0.1 mK, the temperature resolution of Model 350 is 1 mK. The temperature of the shield was kept within the 5 mK when the room temperature variation was about 0.5 K. Conclusion: The resolution of Model 350 for the temperature measurement and control is not good enough as the control system for the compact graphite calorimetry system. But The performance of Model 350 is good enough to maintain the temperature of the shield constantly. The Model 350 will be replaced by the AC resistance bridge (Model 372, Lake Shore Cryogenics) for the core temperature measurement and the jacket control.

07 ISOTOPE AND RADIATION SOURCES↗

Nanoscale Proximity Effect in the High-Temperature Superconductor Bi2Sr2CaCu2O8+δ Using a Scanning Tunneling Microscope

High-temperature cuprate superconductors exhibit extremely local nanoscale phenomena and strong sensitivity to doping. While other experiments have looked at nanoscale interfaces between layers of different dopings, we focus on the interplay between naturally inhomogeneous nanoscale regions. Using scanning tunneling microscopy to carefully track the same region of the sample as a function of temperature, we show that regions with weak superconductivity can persist to elevated temperatures if bordered by regions of strong superconductivity. This suggests that it may be possible to increase the maximum possible transition temperature by controlling the distribution of dopants.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Control of the superconducting properties of Sr{sub 2−x}Ca{sub x}VO{sub 3}FeAs through isovalent substitution

The effect of the isovalent substitution of Sr{sup 2+} by Ca{sup 2+} on the structure and superconducting properties of Sr{sub 2−x}Ca{sub x}VO{sub 3}FeAs is described in the compositional range 0≤x≤0.5. SQUID magnetometry measurements reveal that after an initial increase in T{sub c}, which is maximised at 29.5 K in Sr{sub 1.95}Ca{sub 0.05}VO{sub 3}FeAs, a rapid suppression of superconductivity is observed with increasing x. XANES spectra of Sr{sub 2−x}Ca{sub x}VO{sub 3}FeAs collected on the Fe and V absorption K-edges show that the position of both edges are invariant with composition within the experimental uncertainty. A combination of synchrotron X-ray powder diffraction and neutron powder diffraction techniques is used to rationalise the observed changes in T{sub c} with x, in terms of changes to the structure of the FeAs layer upon partial Ca substitution. These findings demonstrate that superconductivity in the Fe-based superconductors is extremely sensitive to the crystal structure with T{sub c} maximised in samples with regular FeAs{sub 4}-tetrahedra. - Graphical abstract: Superconducting transition temperature is controlled by structural parameters in Sr{sub 2−x}Ca{sub x}VO{sub 3}FeAs. - Highlights: • Substitution of Sr by Ca in the superconductor Sr{sub 2}VO{sub 3}FeAs is isovalent. • Relationship between superconducting T{sub c} and structural parameters is demonstrated. • Linear dependence of T{sub c} on structural parameters rather than composition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of joining technology using local heating for SiC fuel cladding

Silicon carbide (SiC) is an attractive material for an accident-tolerant fuel in light water reactors because of its lower hydrogen-generation rate and lower heat of reaction than conventional Zircaloy. On the other hand, practical application of SiC fuel cladding faces a lot of critical issues, one of which is end-plug joining. The objective of this study is to clarify the feasibility of end-plug joining by silicon brazing using local heating by evaluating the shear strength of joint specimens and producing a circumferential joint experimentally. Silicon is thought to be a compatible joining material with SiC because as well as being a constituent of SiC, its thermal-expansion coefficient is close to that of SiC. Local heating using processes such as laser irradiation and a resistance-heating element needs to be applied for end-plug joining. Brazing is expected to seal a cladding with an end plug by using brief heating without a strong compression force. Shear strength was evaluated using specimens with silicon-brazing joints processed using laser irradiation. The joint sections without defects showed shear strengths higher than or equal to 59 MPa at temperatures from normal room temperature to 1473 K. The average shear strength of the joint (99 MPa) is comparable to that of a diffusion-bonding joint using titanium or molybdenum foil. A tube and a plug were circumferentially joined with silicon brazing using laser irradiation or a graphite heating element. A defocused laser beam was effective for joining without cracking during laser irradiation. Although local heating using a resistance-heating element can more easily control the temperature of the joint, it took longer processing time than that using laser irradiation due to limited temperature-increase rate in order to avoid thermal shock damage. (authors)

36 MATERIALS SCIENCE↗

New hardware and software platform for experiments on a HUBER-5042 X-ray diffractometer with a DISPLEX DE-202 helium cryostat in the temperature range of 20–300 K

Huber-5042 diffractometer with a closed-cycle Displex DE-202 helium cryostat is a unique scientific instrument for carrying out X-ray diffraction experiments when studying the single crystal structure in the temperature range of 20–300 K. To make the service life longer and develop new experimental techniques, the diffractometer control is transferred to a new hardware and software platform. To this end, a modern computer; a new detector reader unit; and new control interfaces for stepper motors, temperature controller, and cryostat vacuum pumping system are used. The system for cooling the X-ray tube, the high-voltage generator, and the helium compressor and pump for maintaining the desired vacuum in the cryostat are replaced. The system for controlling the primary beam shutter is upgraded. A biological shielding is installed. The new program tools, which use the Linux Ubuntu operating system and SPEC constructor, include a set of drivers for control units through the aforementioned interfaces. A program for searching reflections from a sample using fast continuous scanning and a priori information about crystal is written. Thus, the software package for carrying out the complete cycle of precise diffraction experiment (from determining the crystal unit cell to calculating the integral reflection intensities) is upgraded. High quality of the experimental data obtained on this equipment is confirmed in a number of studies in the temperature range from 20 to 300 K.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

On the problem of local tissue hyperthermia control: multiscale modelling of pulsed laser radiation action on a medium with embedded nanoparticles

Methods for solving analytically and numerically the problem of multiscale modelling of the laser hyperthermia processes in a medium with nanoparticles are developed with regard to composite spherical nanoparticles (nanoshells). The features of the laser radiation field localisation on nanoscale inhomogeneities are investigated. Issues related to the control of the tissue hyperthermia processes by choosing the parameters of spatiotemporal localisation of the laser beam and of the absorbing nanoparticles are discussed. (application of lasers and laser-optical methods in life sciences)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermal characteristics of air flow cooling in the lithium ion batteries experimental chamber

A battery pack prototype has been designed and built to evaluate various air cooling concepts for the thermal management of Li-ion batteries. The heat generation from the Li-Ion batteries was simulated with electrical heat generation devices with the same dimensions as the Li-Ion battery (200 mm x 150 mm x 12 mm). Each battery simulator generates up to 15W of heat. There are 20 temperature probes placed uniformly on the surface of the battery simulator, which can measure temperatures in the range from -40 C to +120 C. The prototype for the pack has up to 100 battery simulators and temperature probes are recorder using a PC based DAQ system. We can measure the average surface temperature of the simulator, temperature distribution on each surface and temperature distributions in the pack. The pack which holds the battery simulators is built as a crate, with adjustable gap (varies from 2mm to 5mm) between the simulators for air flow channel studies. The total system flow rate and the inlet flow temperature are controlled during the test. The cooling channel with various heat transfer enhancing devices can be installed between the simulators to investigate the cooling performance. The prototype was designed to configure the number of cooling channels from one to hundred Li-ion battery simulators. The pack is thermally isolated which prevents heat transfer from the pack to the surroundings. The flow device can provide the air flow rate in the gap of up to 5m/s velocity and air temperature in the range from -30 C to +50 C. Test results are compared with computational modeling of the test configurations. The present test set up will be used for future tests for developing and validating new cooling concepts such as surface conditions or heat pipes.

25 ENERGY STORAGE↗

Beyond Orientation: The Impact of Electric Fields on Block Copolymers

Since the first report on electric field-induced alignment of block copolymers (BCPs) in 1991, electric fields have been shown not only to direct the orientation of BCP nanostructures in bulk, solution, and thin films, but also to reversibly induce order-order transitions, affect the order-disorder transition temperature, and control morphologies' dimensions with nanometer precision. Theoretical and experimental results of the past years in this very interesting field of research are summarized and future perspectives are outlined.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

In situ X-ray characterization of uranium dioxide during flash sintering

The in situ response of stoichiometric and non-stoichiometric uranium dioxide during flash sintering is examined using high energy X-ray diffraction. Our results show that the onset of flash is driven by an increase in temperature and controlled by the applied field with no evidence of an accumulation of defects. The incubation time, that is the time after the application of the field before the flash occurs, is found to be material specific with hyper-stoichiometric samples requiring lower fields to flash. For low current/voltage fields we quantify very little change in the atomic and microstructure of the different uranium dioxide samples post-flash. Microstructural changes are identified for high fields and currents, where joule heating and sample temperatures are high, resulting in the complete transformation of the U 4 O 9 phase. Our results highlight the usefulness of high energy X-ray characterization in understanding the subtle structural changes that occur during the flash sintering process.

36 MATERIALS SCIENCE↗

Low-Temperature Annealing of Nanoscale Defects in Polycrystalline Graphite

Polycrystalline graphite contains multi-scale defects, which are difficult to anneal thermally because of the extremely high temperatures involved in the manufacturing process. In this study, we demonstrate annealing of nuclear graphite NBG-18 at temperatures below 28 °C, exploiting the electron wind force, a non-thermal stimulus. High current density pulses were passed through the specimens with a very low-duty cycle so that the electron momentum could mobilize the defects without heating the specimen. The effectiveness of this technique is presented with a significant decrease in electrical resistivity, defect counts from X-ray computed tomography, Raman spectroscopy, and nanoindentation-based mechanical characterization. Such multi-modal evidence highlights the feasibility of nanoscale defect control at temperatures about two orders of magnitude below the graphitization temperature.

Liu, Gongyuan↗

Environmental variables associated with vacationers' sun protection at warm weather resorts in North America

Background: Vacationing at sunny, warm weather locations is a risk factor for excessive solar ultraviolet (UV) radiation exposure and skin cancer. Objectives: This study examined the association of environmental variables related to UV levels with vacationers' sun protection. Methods: Vacationers at 41 summer resorts in 17 states and 1 Canadian Province were interviewed (n=3531) and observed (N=4347) during 2012 and 2013. Clothing coverage, sunglasses, and shade use were observed. Use of sunscreen and sunburns were self-reported. Environmental information was recorded by research staff or acquired from ground stations and the weather service. Results: Temperature was positively associated with sun protection behaviors; however clothing coverage was negatively associated with temperature. Cloud cover was negatively associated with sun protection, with the exception of clothing coverage which was positively associated with it. Elevation showed a mixed pattern of associations with vacationer's sun protection. Latitude of a resort was negatively associated with most sun protection behaviors, such that sun protection increased at more southerly resorts. Similarly, the farther south a vacationer traveled to the resort, the less sun protection they employed. The UV index showed a weak, positive relationship with some sun protection behaviors even when controlling for temperature. Conclusions: Vacationers appeared aware that UV is higher at southern latitudes and may learn UV is intense when living in southern regions. However, many used temperature, an unreliable cue, to judge UV intensity and seemed to adjust clothing for warmth not UV protection. Efforts are needed to help individuals make more accurate sun safety decisions. - Highlights: • Vacationers poorly monitor and protect against environmental ultraviolet radiation (UVR). • On cloudy days vacationers fail to protect against UVR. • Temperature is erroneously used by vacationers as a marker for UVR. • Clothing is used primarily by vacationers for warmth, not UVR protection. • The farther south a vacationer travels, the more likely they are to sunburn.

79 ASTRONOMY AND ASTROPHYSICS↗

Hydrological and Thermal Dynamics of a Supra‐Permafrost Subterranean Estuary

Subterranean estuaries (STEs), where groundwater interacts with seawater, influence surface and subsurface coastal ecology and biogeochemistry. In Arctic-STEs overlying permafrost, groundwater flow and heat transport determine the fate of organic matter. Yet, direct observations of groundwater flow and heat and solute transport processes in Arctic STEs remain limited. This study characterized groundwater flow paths and fluxes and heat transport within an Arctic-STE along Alaska's Beaufort Sea coast during thawing, summer, and freeze-up. Intertidal seabed temperature-depth profiles collected along a 10-m transect captured the active groundwater flow period, from thaw and flow onset in mid-June to freeze-up in late-September. During this period, aquifer geometry evolved non-uniformly due to spatially varying thaw rates across the STE (mean (m) thaw depths–beach: 0.25 to 0.55–0.6 m on 20 June, 25 July, 1 October; seabed: 0.6–0.9 m from 25 July to 1 October). Groundwater and surface water levels, salinity, and subsurface temperature profiles measured over tidal time scales were interpreted alongside groundwater flow-heat transport numerical simulations. Fresh groundwater discharge was sporadic during thawing (m: 0.32 m 3 /day/m), abundant in summer (m: 0.45 m 3 /day/m), and was largely absent during freeze-up. During freeze-up, groundwater flow was driven exclusively by seawater recirculation via tidal pumping (from thawing to summer to freeze-up: 0.00025–0.15–0.5 m3/day/m) and convection. Heat advection dominated near aquatic interfaces (shaping intertidal ice), and conduction controlled vertical temperature gradients in low-flow and unsaturated sediments. These findings will help predict how prolonged summers will alter Arctic-STE cryo-hydrology and biogeochemistry.

54 ENVIRONMENTAL SCIENCES↗

Probing hysteretic elasticity in weakly nonlinear materials

Our work is aimed at assessing the elastic and dissipative hysteretic nonlinear parameters' repeatability (precision) using several classes of materials with weak, intermediate and high nonlinear properties. In this contribution, we describe an optimized Nonlinear Resonant Ultrasound Spectroscopy (NRUS) measuring and data processing protocol applied to small samples. The protocol is used to eliminate the effects of environmental condition changes that take place during an experiment, and that may mask the intrinsic elastic nonlinearity. As an example, in our experiments, we identified external temperature fluctuation as a primary source of material resonance frequency and elastic modulus variation. A variation of 0.1 C produced a frequency variation of 0.01 %, which is similar to the expected nonlinear frequency shift for weakly nonlinear materials. In order to eliminate environmental effects, the variation in f{sub 0} (the elastically linear resonance frequency proportional to modulus) is fit with the appropriate function, and that function is used to correct the NRUS calculation of nonlinear parameters. With our correction procedure, we measured relative resonant frequency shifts of 10{sup -5} , which are below 10{sup -4}, often considered the limit to NRUS sensitivity under common experimental conditions. Our results show that the procedure is an alternative to the stringent control of temperature often applied. Applying the approach, we report nonlinear parameters for several materials, some with very small nonclassical nonlinearity. The approach has broad application to NRUS and other Nonlinear Elastic Wave Spectroscopy approaches.

58 GEOSCIENCES↗

Thermostatic Radiator Valve Evaluation and Demonstration

A large stock of multifamily buildings in the Northeast and Midwest uses hot water or steam for space heating. Typically, residents do not pay for heat directly (i.e., heating fuel serves a central plant and use is not submetered). Losses from these systems are typically high, and a significant number of apartments are overheated much of the time. This is often evidenced by open windows on winter days. Controls and distribution are often faulty, and improving them can be more cost effective than replacing boilers. Thermostatic radiator valves (TRVs), which have been in use for many decades, are one potential strategy to combat this problem. They are commonly used in Europe and in other markets such as commercial buildings, but have not been widely accepted by the residential retrofit market in the northeastern United States. Anecdotal evidence suggests that heating systems engineers and contractors have a variety of opinions about their effectiveness, illustrating a lack of consensus on this potentially important energy efficiency measure. A review of the limited available literature revealed that, in one study, heating fuel savings as high as 15% was achieved through TRV retrofits. In this project, the U.S. Department of Energy Building America team, Advanced Residential Integrated Energy Solutions, sought to better understand the current usage of TRVs by key market players in steam and hot water heating and to conduct limited experiments on the effectiveness of new and old TRVs as a means of controlling space temperatures and reducing heating fuel consumption. The project included a survey of industry professionals, a field experiment comparing old and new TRVs, and cost-benefit modeling analysis using BEopt (Building Energy Optimization software). Radiator and apartment space temperature data were collected and analyzed for two similar apartment units in a building that underwent a one-pipe steam TRV retrofit. Space temperature comparisons were made across the pre- and post-TRV installation heating periods and between rooms equipped with old or new TRVs in an attempt to show the comparative effectiveness of each vintage of TRV. Analyses of the heating fuel utility bills before and after the building-wide TRV installation were conducted to quantify potential savings. The results of the field experiment and utility bill analysis did not show energy savings at either the unit or the building-wide level. The results provided inconclusive answers to the original study questions but provided valuable insight into common steam system imbalance and resident behavior issues that are critical to address in conjunction with TRV retrofits. Specific issues identified included steam distribution imbalance, possible TRV sensor location issues, a persistent window-opening habit, and a failure to optimize the boiler control set points as part of the TRV retrofit. The lack of heating fuel savings underscored the need to include whole steam system commissioning alongside or as a prerequisite to TRVs. Failed air vents and uneven steam main venting are critical to address either in conjunction with or before a TRV installation. Monitoring existing space temperatures before a retrofit strategy is chosen would allow the consultant and building owner to better assess the potential benefits of a whole-building TRV retrofit, selective installation of TRVs in some units, or simply balancing the steam distribution venting. Further gaps in the understanding of underlying processes that allow TRVs to function effectively were also identified and are presented as opportunities for future research.

Array↗

Analysis of N-16 concentration in primary cooling system of AP1000 power reactor

Nitrogen-16 (N-16) is one of the radiation safety parameter on the primary reactor system. The activation product, N-16, is the predominant contributor to the activity in the reactor coolant system during reactor operation. N-16 is activation product derived from activation of O-16 with fast neutron based on {sup 16}O(n,p){sup 16}N reaction. Thus study is needed and it performs to determine N-16 concentration in reactor coolant (primary coolant) in supporting radiation safety. One of the way is using analytical methode based on activation and redecay princip to obtain N-16 concentration. The analysis was performed on the configuration basis and operational of Westinghouse AP1000 power reactor in several monitoring points at coolant reactor system. The results of the calculation of N-16 concentration at the core outlet, reactor vessel outlet, pressurizer line, inlet and outlet of steam generators, primary pumps, reactor vessels inlet and core inlet are: 281, 257, 255, 250, 145, 142, 129 and 112 µCi/gram respectively. The results of analysis compared with AP1000 design control document as standard values. The verification showed very high accuracy comparation between analytical results and standard values.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Process with Decoupled Absorber Kinetics and Solvent Regeneration through Membrane Dewatering and In-Column Heat Transfer (Final Report)

This report summarizes the work conducted on project DE-FE0031604 where University of Kentucky Center for Applied Energy (UK CAER) has validated its intensified CO 2 capture process through substantial enhancements to the kinetics of the absorption process and energy reductions by absorber temperature profile modification, dewatering and heat integration technologies for achieving significant capital and operating cost reductions. To address DOE’s objective of improving post-combustion CO 2 capture technology and reducing associated cost, UK CAER employed an intensified process which combined three key aspects targeted at overcoming inherent limitations or barriers in the conventional CO 2 capture and desorption process. The process designed to be independent of the type of solvent used, included (1) the use of 3-D printed two-channel structured packing material to control the temperature profile and increase the CO 2 absorption rate in the absorber, (2) a zeolite membrane dewatering unit for dewatering of the carbon-rich solvent to decouple solvent concentration needs for CO 2 absorption and desorption, and (3) a rich-split feed with two-phase flow heat transfer prior to the stripper that provided a secondary point of vapor generation to provide energy savings in steam extraction and solvent regeneration. The project was executed over two budget periods. This involved testing of individual process components which included the advanced heat transfer packing and the dewatering membrane on UK CAER’s 30 liter per minute (L/min) CO 2 (3” Column) capture bench unit with simulated flue gas in the first budget period. Subsequent scaled-up testing of these components together with the split-feed configuration were also tested in UK CAER’s 0.1 MWth CO 2 capture unit with coal-derived flue gas in the second-budget period. Long term studies were done during this period to assess process and solvent performance over extended duration. Project partners Lawrence Livermore National Laboratory (LLNL) and Media & Process Technology (MPT) led the development efforts for the advanced packing material and dewatering membrane respectively. Data from the long term testing was used as input for an environmental, health and safety (EH&S) assessment for the process and scaled technology performed by ALL4 LLC. Trimeric Corporation also completed a techno-economic analysis (TEA) for the UK CAER technology which was compared to the DOE reference Case B12B. Tests on the 3” column capture unit showed that the advanced heat transfer packing could be used to lower the bulge temperature in the absorber, and this was also proven in the scaled testing in the 0.1 MWth CO 2 capture unit. The bulge temperature could be lowered by >10 °C, changing the temperature profile in the absorber, and showed potential to enhance absorption with the ability to tailor the profile to provide conditions suitable for a solvent’s properties and kinetics. Conditions for short term evaluation of a 19” zeolite dewatering membrane on the 3” column capture unit yielded desirable fluxes and sustained rejection rates of >80%. However, for the scaled testing of six membrane modules consisting of 21 parts of 31-inch-long membrane tubes in each bundle (surface area 0.3 m 2 ), over a more extended duration, similar rejection rates could not be achieved. With the split-feed of the rich stream to the stripper, improved heat recovery minimized waste heat exiting the top of the stripper. The stripper exhaust temperatures could be reduced by >10 °C; reducing the amount of water vaporization contributed to lowering the regeneration energy by ~ 15%. The energy benefit could be sustained from the long term monitoring of the solvent performance. The solvent properties were not significantly impacted over the long-term operations. The benefits of the UK CAER process demonstrated experimentally were mostly validated from the TEA comparing a commercial scale application of the technology to DOE reference Case B12B. The cost of CO 2 capture for the UK CAER technology was estimated to be ~$34.97/tonne of CO 2 captured; a reduction of 23% compared to Case B12B. The increase in cost of electricity was also shown to be 16% lower than that of Case B12B. The total parasitic demand was also shown to be 11% lower. The key drivers for the benefits are a result of the process intensification approaches employed in the UK CAER technology for enhanced solvent performance, effective heat recovery and improved energy performance. The EH&S assessment did not find any major environmental concerns or barriers to the full scale implementation of the technology.

20 FOSSIL-FUELED POWER PLANTS↗