Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TREAT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Assessment of Pump-and-Treat System Impacts on 200 West Aquifer Conditions

The 200 West P&T system is one of the key components of the final remedy selected for the 200-ZP-1 Operable Unit (OU), and the interim remedial action selected for 200-UP-1 OU at the Hanford Site. In addition, the facility has been receiving water from several other sources, such as 200-DV-1 OU perched water, groundwater from the 200-BP-5 OU, and leachate from the Environmental Restoration Disposal Facility. It is anticipated that the P&T system will continue to receive water from other sources, which may include Modular Storage Unit (purge) water, groundwater near the Waste Management Area C, and Gable Gap. Furthermore, maintaining the injection capacity of the system has been a significant issue since the facility startup in 2012. Fouling issues at the injection wells have necessitated frequent well redevelopment, resulting in decrease in injection capacity and the need to construct new injection wells—with significant effects on system performance and operational costs. Given the evolving nature of treatment plant effluent due to changes in influent, combined with issues observed at the injection wells, it is important to understand the impacts of the P&T operations on the 200 West aquifer where the treated water is injected. This study aims at determining these impacts and providing a quantitative evaluation of aquifer capacity for both current and future conditions. This information will provide a technical basis for decisions related to the P&T system operations that support remedy optimization efforts and short- and long-term remedy decisions related to multiple OUs in the Central Plateau.

Demirkanli, Deniz I.↗

Cornerstone Resources Feedstock Characterization and Conversion Assessment of Treated MSW Materials (CRADA Closeout Final Report)

Cornerstone Resources has developed a proprietary advanced preprocessing technology, the BurCell® System, for production of a high quality organic biomass feedstock from numerous waste resources. While suitable for a variety of feedstock, the focus of development for the BurCell® System has been thus far municipal solid waste (MSW). In MSW, the system technology is able to capture non-recyclable waste paper, cardboard, and organic materials, homogenize these materials and allow for separation of the non-organic fraction. The resulting homogenized organic material typically represents in excess of 50% of the raw MSW feed. The recently released Billion Ton Study now includes MSW as a feedstock resource showing it to be one of the lowest cost and most widely distributed biomass resources available; however, acknowledging the concerns with the potential physical and chemical variability of an MSW based feedstock stream. The focus on MSW has also been driven by MSW being a resource with a clear, well understood and mature supply-chain. Treating MSW in the BurCell® System will make that source of biomass substantially more accessible. To further promote the use of this MSW derived biomass and beneficially exploit the use of the BurCell® System for processing of biomass for Bioenergy production facilities, more detailed lab data is now required.

09 BIOMASS FUELS↗

Analysis of Technetium Ion Exchange Resin from the 200 West Pump-and-Treat Facility

The 200 West Area Pump-and-Treat (P&T) facility at the Hanford Site is a combined treatment train consisting of unit processes to remove radionuclides such as uranium (U) and technetium (Tc-99), other inorganic (nitrate and hexavalent chromium), and organic (carbon tetrachloride and trichloroethene) contaminants. The RAD building of the P&T facility removes Tc-99 and U using ion exchange chromatography, while the other inorganic and organic contaminants are removed in the facility’s BioPlant portion. The original design of the ion exchange resin for Tc-99 allowed for a 3-month Tc-99 breakthrough and subsequent resin canister change out. However, no Tc-99 breakthrough was noted for 3 years. The objective of the work was to analyze spent resin to determine if there are other compounds that may interfere with Tc-99 adsorption, and to determine whether the resin was removing any I-129.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Biochemical Characterization of the Influences of Pump-and-Treat Remediation on Aquifer Conditions on the Central Plateau of the Hanford Site

The aim of this research was to quantify and characterize the organic carbon present in the subsurface on the Hanford site, specifically where groundwater pump-and-treat (P&T) operations are currently taking place. The primary purpose of P&T is to remediate groundwater contaminants, however water treatment can alter subsurface conditions by introducing a low, but consistent supply of organic carbon to the subsurface. These inputs have not been characterized and the consequences therein have not been considered prior. Approximately 40 L of groundwater from the P&T facility was processed by stepwise ultra-filtration for carbon characterization. Groundwater was first filtered to remove particulate organic carbon (POC) and colloids (operationally defined as > 0.2 µm) and subsequently, two size fractions of dissolved organic carbon (DOC, operationally defined as <0.2 µm), the > 10 kDa fraction and the >5 kDa fraction. POC was analyzed via X-Ray powder Diffraction (XRD) for structural and phase characterization of groundwater particulates. Dissolved organic carbon (10 kDa fraction) was quantified using a total carbon analyzer (NPOC, non-particulate organic carbon) and the chemical character of this carbon further defined by specific UV absorption and Fourier-Transform Ion Cyclotron Resonance - Mass Spectrometry (FTICR-MS). This detailed analysis of groundwater carbon reveals how P&T operations are affecting subsurface nutrient dynamics, which in turn could have a positive feedback on natural attenuation pathways in the 200W contaminant plume at the Hanford Site.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mercury Speciation and Quantification of Hanford 241-AP-107 Tank Waste Feed and Treated Samples

This report describes the second phase of a multi year project to adapt and develop an analytical technique for the low-level determination of total mercury (HgT), elemental mercury (Hg0), and monomethyl mercury (MeHg, hereafter referred to as methyl mercury) in Hanford tank waste. The focus of Phase II was to quantify the mercury (Hg) species total, elemental, and methyl mercury from a raw sample and treated (i.e., filtered and cesium-decontaminated) waste samples originating from Hanford waste tank 241-AP 107. The focus of Phase I work was to determine if mercury species can be preconcentrated from aqueous Hanford tank waste solution onto a solid adsorbent while simultaneously eliminating or very significantly reducing the parent radionuclide activity. This was demonstrated by developing protocols for the preparation, separation, and collection of total mercury and methyl mercury onto solid adsorbents, then measuring the adsorbents for radiological content at Pacific Northwest National Laboratory’s (PNNL’s) Radiochemical Processing Laboratory (RPL) on the Hanford Site. During Phase II, the Hanford tank waste material was preserved, separated (through distillation or digestion), then collected as either solid adsorbents or into liquid distillate form at the RPL and transferred to the PNNL Marine Sciences Laboratory (MSL) in Sequim, Washington, for analysis and quantification. Quantification of total, elemental, and methyl mercury was conducted under radiological control at the MSL using the ultra trace analytical capabilities available there.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Status of Mock-up and Integration for Ultrasonic Deformation Sensor for TREAT Experiments

Fuel deformation (both axial and radial) information provides insights into fuel performance and failure limits. Traditionally, fuel deformation has been quantified using post-irradiation examinations due to the lack of an appropriate sensor for monitoring deformation in situ. Recent developments in sensor and instrumentation design have led to the use of linear variable differential transducers (LVDT) for monitoring axial strain in fuel during irradiation. Size and operational constraints limit the use of LVDT sensors for radial deformation monitoring, and alternatives are needed. One possible alternative to LVDT sensors is an ultrasonic sensor. Ultrasonic sensors monitor the interaction of high-frequency stress waves with the test object. The resulting response may be analyzed to determine the properties of the material, including stress, strain, microstructure, presence of defects, and the elastic constants. While ultrasonic measurements have been successfully applied for monitoring strain in a number of applications, their use for in-core measurements has been limited. Largely, the limitations are due to the challenges associated with designing sensors that can operate under typical in-core conditions. This report documents progress to date toward planning, construction, and testing of a mock-up test capsule/facility to be used for in-lab testing of ultrasonic displacement sensor designs and toward integration of the sensor into prototypic TREAT experiment designs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Second Annual Progress Report on Ultrasonic Sensors for TREAT Fuel Condition Measurement and Monitoring

Fuel deformation (both axial and radial) information provides insights into fuel performance and failure limits. Traditionally, fuel deformation has been quantified using post-irradiation examinations due to the lack of an appropriate sensor for monitoring deformation in situ. Recent developments in sensor and instrumentation design have led to the use of linear variable differential transformers (LVDT) for monitoring axial strain in fuel during irradiation. Size and operational constraints limit the use of LVDT sensors for radial deformation monitoring, and alternatives are needed. One possible alternative to LVDT sensors is an ultrasonic sensor. Ultrasonic sensors monitor the interaction of high-frequency stress waves with the test object. The resulting response may be analyzed to determine the properties of the material, including stress, strain, microstructure, presence of defects, and the elastic constants. While ultrasonic measurements have been successfully applied for monitoring strain in a number of applications, their use for in-core measurements has been limited. Largely, the limitations are due to the challenges associated with designing sensors that can operate under typical in-core conditions. The overall objective of this work is to design an ultrasonic sensor capable of rapid in-situ measurements of fuel rodlet dimensional changes during TREAT transient irradiation testing. This report summarizes the activities and research findings through the end of Year 2 of this three-year project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Groundwater Pump and Treat System Optimization Report U.S. DOE NNSA Pantex Plant, Texas

This document details the approach and presents the results for the optimization of the perched groundwater pump and treat (P&T) systems at the Pantex Plant, located in the Texas panhandle (Figure 1.1). Recommendations from the second Five-Year Review (FYR) for the Pantex Plant (HGL, 2018) and objectives specified in the 2007 Record of Decision (ROD) are the basis of the optimization effort.

54 ENVIRONMENTAL SCIENCES↗

Reconfiguration of the Respiratory Tract Microbiome to Prevent and Treat Burkholderia Infection

New approaches to preventing and treating infections, particularly of the respiratory tract, are needed. One promising strategy is to reconfigure microbial communities (microbiomes) within the host to improve defense against pathogens. Probiotics and prebiotics for gastrointestinal (GI) infections offer a template for success. We sought to develop comparable countermeasures for respiratory infections. First, we characterized interactions between the airway microbiome and a biodefense-related respiratory pathogen ( Burkholderia thailandensis ; Bt), using a mouse model of infection. Then, we recovered microbiome constituents from the airway and assessed their ability to re-colonize the airway and protect against respiratory Bt infection. We found that microbiome constituents belonging to Bacillus and related genuses frequently displayed colonization and anti-Bt activity. Comparative growth requirement profiling of these Bacillus strains vs Bt enabled identification of candidate prebiotics. This work serves as proof of concept for airway probiotics, as well as a strong foundation for development of airway prebiotics.

59 BASIC BIOLOGICAL SCIENCES↗

Thermal Characterization of Acid Treated Anion Exchange Resins

Anion exchange is a chemical separation and purification technique in which a solid phase ion exchanging material (i.e., anion exchange resin beads) interchanges its anions with the desired anions from a solution phase. Typical anion exchange resins (e.g., Bio-Rad AG 1-X8 strongly basic anion exchange resin) consist of a polymer resin bead of cross-linked polystyrene with quaternary ammonium functional groups (Figure 1). Anion exchange occurs at the resin functional groups by exchange of the counter ion of the quaternary ammonium (typically chloride or nitrate) for the anionic species of interest. Other resin polymers have been developed—such as cross-linked vinylpyridine/divinylbenzene utilized in Reillex HPQ anion exchange resin—to improve the resins’ resistance against degradation by oxidizing agents, strong acids, and radiation. Anion exchange is performed for the separation of transuranic (TRU) elements throughout the Department of Energy complex. At the Los Alamos National Laboratory (LANL), production scale quantities of these resins are handled at the Chemistry and Metallurgy Research Facility, the Plutonium Facility, and the Transuranic Waste Facility. Spent anion exchange resin will eventually be disposed of as TRU waste. This has prompted concerns regarding its safe disposal under potential hazard scenarios, in particular a thermal excursion of a TRU waste drum. There is a concern that a potential thermal excursion of a TRU waste drum containing anion exchange resin previously contacted with nitric acid may result in energetic side reactions and pressure buildup due to resin degradation by nitric acid and heat. Therefore, the objective of the experiments described in this report was to gather qualitative and quantitative data to support decisions regarding the thermal stability and safe disposal strategy of nitric acid treated anion exchange resins utilized in TRU processing operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Geophysical Characterization and Monitoring of the 200 Area Treated Effluent Disposal Facility to Support Permit Renewal; TEDF Geophysical Monitoring

The Treated Effluent Disposal Facility (TEDF), located in the 200 East Area of the Hanford Site, is a site where non-hazardous and non-radioactive liquid wastes are disposed into two state-permitted infiltration basins. In 2016, the Washington State Department of Ecology denied a permit renewal request for TEDF due to the inability to adequately assess the impact of TEDF discharge water on the underlying groundwater quality. TEDF overlies the relatively impermeable Ringold Lower Mud (RLM) unit, whose upper contact lies in the vadose zone approximately 30 m below ground surface and approximately 10 m above the water table boundary. The RLM is assumed to isolate TEDF discharge water from the natural groundwater aquifer, which is monitored using wellbores screened below the RLM. Therefore, samples collected from monitoring wells near TEDF are not considered representative of TEDF discharge water. Rather, TEDF discharge water is assumed to mound on top of the RLM to form a perched aquifer. To support permitting of the TEDF, a new monitoring well is required that can be used to sample water from the presumed perched water aquifer above the RLM. Ideally, the screened section of the well would be located at the peak of the perched water mound(s), which presumably occurs at the point of maximum vertical flux from TEDF to the RLM, or equivalently where the dominant infiltration flow paths reach the RLM. This report describes how time-lapse 3D electrical resistivity tomography (ERT) was used in conjunction with nominal TEDF discharge operations to image the dominant flow paths from each pond to the RLM. Results are summarized in Figure ES.1. Figure ES.1A shows a satellite image of the TEDF overlain by an array of surface ERT electrodes. The solid and dashed black circles denote the zones of maximum vertical flux at the RLM within the south and north ponds, respectively, and presumably the regions where perched water peaks during discharge. Figure ES.1B shows time-lapse difference imaging results approximately 15 days after switching discharge from the south pond to the north pond. Blue iso-surfaces beneath the north pond denote regions of increasing bulk electrical conductivity caused by increasing saturation due to infiltrating water. Red iso-surfaces beneath the south pond denote regions that were previously saturated during the south pond discharge and are now de-saturating, causing a decrease in bulk electrical conductivity. In both cases, the zones of maximum change mark the dominant flow paths to the RLM. Figure ES.1C shows time-lapse imaging results approximately 15 days after switching discharge from the north pond to the south pond. In this case, blue iso-surfaces mark the dominant flow paths to the RLM from the south pond. The red iso-surfaces mark the dominant flow paths that existed during discharge to the north pond. The regions of maximum change in bulk conductivity (due to saturation or desaturation) that mark the primary flow paths are equivalent in both cases and denoted by the dashed solid and black circles. If a perched water zone forms on the RLM, it is likely to mound within or near the dashed circle during discharge to the north pond, and in the solid circle during discharge to the south pond. In other words, if perched water mounding occurs, the circles mark the optimum locations suggested by the ERT imaging for monitoring boreholes to be placed, enabling samples to be collected that are representative of TEDF discharge impacts on groundwater quality.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DETAILED ANALYSIS OF THE MOST PROMISING ALTERNATIVES TO USING GRANULAR ACTIVATED CARBON TO TREAT 200-ZP-1 GROUNDWATER AND 200-PW-1 SOIL VAPOR

This document presents a detailed evaluation of selected alternative treatment options to granular activated carbon (GAC) for removing carbon tetrachloride generated from the groundwater pump-and-treat system at the 200-ZP-I Operable Unit (OU) in the 200 West Area of the Hanford Site. This evaluation of alternative treatment options to GAC is also applicable to the vadose zone soil vapor extraction (SVE) system at the 200-PW-l OU, which is also located in the Hanford Site's 200 West Area.

54 ENVIRONMENTAL SCIENCES↗

Treating Coalbed Natural Gas Produced Water for Beneficial Use By MFI Zeolite Membranes

Desalination of brines produced from oil and gas fields is an attractive option for providing potable water in arid regions. Recent field-testing of subsurface sequestration of carbon dioxide for climate management purposes provides new motivation for optimizing efficacy of oilfield brine desalination: as subsurface reservoirs become used for storing CO{sub 2}, the displaced brines must be managed somehow. However, oilfield brine desalination is not economical at this time because of high costs of synthesizing membranes and the need for sophisticated pretreatments to reduce initial high TDS and to prevent serious fouling of membranes. In addition to these barriers, oil/gas field brines typically contain high concentrations of multivalent counter cations (eg. Ca{sup 2+} and SO{sub 4}{sup 2-}) that can reduce efficacy of reverse osmosis (RO). Development of inorganic membranes with typical characteristics of high strength and stability provide a valuable option to clean produced water for beneficial uses. Zeolite membranes have a well-defined subnanometer pore structure and extreme chemical and mechanical stability, thus showing promising applicability in produced water purification. For example, the MFI-type zeolite membranes with uniform pore size of {approx}0.56 nm can separate ions from aqueous solution through a mechanism of size exclusion and electrostatic repulsion (Donnan exclusion). Such a combination allows zeolite membranes to be unique in separation of both organics and electrolytes from aqueous solutions by a reverse osmosis process, which is of great interest for difficult separations, such as oil-containing produced water purification. The objectives of the project 'Treating Coalbed Natural Gas Produced Water for Beneficial Use by MFI Zeolite Membranes' are: (1) to conduct extensive fundamental investigations and understand the mechanism of the RO process on zeolite membranes and factors determining the membrane performance, (2) to improve the membranes and optimize operating conditions to enhance water flux and ion rejection, and (3) to perform long-term RO operation on tubular membranes to study membrane stability and to collect experimental data necessary for reliable evaluations of technical and economic feasibilities. Our completed research has resulted in deep understanding of the ion and organic separation mechanism by zeolite membranes. A two-step hydrothermal crystallization process resulted in a highly efficient membrane with good reproducibility. The zeolite membranes synthesized therein has an overall surface area of {approx}0.3 m{sup 2}. Multichannel vessels were designed and machined for holding the tubular zeolite membrane for water purification. A zeolite membrane RO demonstration with zeolite membranes fabricated on commercial alpha-alumina support was established in the laboratory. Good test results were obtained for both actual produced water samples and simulated samples. An overall 96.9% ion rejection and 2.23 kg/m{sup 2}.h water flux was achieved in the demonstration. In addition, a post-synthesis modification method using Al{sup 3+}-oligomers was developed for repairing the undesirable nano-scale intercrystalline pores. Considerable enhancement in ion rejection was achieved. This new method of zeolite membrane modification is particularly useful for enhancing the efficiency of ion separation from aqueous solutions because the modification does not need high temperature operation and may be carried out online during the RO operation. A long-term separation test for actual CBM produced water has indicated that the zeolite membranes show excellent ion separation and extraordinary stability at high pressure and produced water environment.

03 NATURAL GAS↗

Using a recirculating anaerobic dynamic membrane bioreactor to treat hydrothermal liquefaction aqueous by-product

Hydrothermal liquefaction (HTL) has the potential to improve resource recovery at water resource recovery facilities (WRRF), but the production of a high-strength aqueous by-product (HTL-aq) is hampering HTL implementation. The formation of biofilms in anaerobic digestion have been shown to be useful when degrading recalcitrant compounds present in HTL-aq due to the promotion of direct interspecies electron transfer (DIET) and increase in the microbial activity of syntrophic and methanogenic populations. The Recirculating Anaerobic Dynamic Membrane Bioreactor (RAnDMBr) was able to degrade 65% of the chemical oxygen demand (COD) at 1.5 ± 0.2 g COD LR −1 day −1 and 5.6 ± 2.3 days producing 0.19 ± 0.02 LCH4 gCOD fed −1 . However, adding a solution rich in nutrients on a daily basis was necessary. The system presented microbial populations able to degrade aromatic compounds (i.e., Anaerolinaceae) to perform DIET and syntrophy (i.e., Syntrophus) and methanogens (i.e., Methanobacterium and Methanosarcina) with the biofilm having a higher relative abundance of methanogens than the suspended biomass. Increasing the organic loading rate to 2 g COD LR −1 day −1 caused inhibition in the system by accumulation of volatile fatty acids, probably due to an increase in phenol, N-heterocyclic and aromatic compounds. Overall, this research shows that the RAnDMBr can be used to treat HTL-aq in WRRF without inhibition at OLRs of 1.5 ± 0.2 g COD LR −1 day −1 or lower, making HTL-aq treatment more feasible. Future research should focus co-digestion of HTL-aq with a co-substrate rich in nutrients and on fouling mitigation strategies that will allow to increase the recirculation ratio to promote advective substrate transport through the biofilm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Plasma Treating Mixed Metal Oxides to Improve Oxidative Performance via Defect Generation

The generation of structural defects in metal oxide catalysts offers a potential pathway to improve performance. Herein, we investigated the effect of thermal hydrogenation and low-temperature plasma treatments on mixed SiO 2 /TiO 2 materials. Hydrogenation at 500 °C resulted in the reduction of the material to produce Ti 3+ in the bulk TiO 2 . In contrast, low temperature plasma treatment for 10 or 20 min generated surface Ti 3+ species via the removal of oxygen on both the neat and hydrogenated material. Assessing the photocatalytic activity of the materials demonstrated a 40–130% increase in the rate of formic acid oxidation after plasma treatment. A strong relationship between the Ti 3+ content and catalyst activity was established, although a change in the Si–Ti interaction after plasma treating of the neat SiO 2 /TiO 2 material was found to limit performance, and suggests that performance is not determined solely by the presence of Ti 3+ .

36 MATERIALS SCIENCE↗

Hydrogen Peroxide Interference in Chemical Oxygen Demand Assessments of Plasma Treated Waters

Plasma-driven advanced oxidation represents a potential technology to safely re-use waters polluted with recalcitrant contaminants by mineralizing organics via reactions with hydroxyl radicals, thus relieving freshwater stress. The process results in some residual hydrogen peroxide, which can interfere with the standard method for assessing contaminant removal. In this work, methylene blue is used as a model contaminant to present a case in which this interference can impact the measured chemical oxygen demand of samples. Next, the magnitude of this interference is investigated by dosing de-ionized water with hydrogen peroxide via dielectric barrier discharge plasma jet and by solution. The chemical oxygen demand increases with increasing concentration of residual hydrogen peroxide. The interference factor should be considered when assessing the effectiveness of plasma to treat various wastewaters.

Groele, Joseph↗

Spray Drying Enzyme-Treated Cellulose Nanofibrils

Enzyme-treated cellulose nanofibrils (CNFs) were produced via a lab-scale mass colloider using bleached kraft pulp (BKP) to evaluate their processability and power requirements during refining and spray-drying operations. To evaluate the energy efficiency in the CNF refining process, the net energy consumption, degree of polymerization (DP), and viscosity were determined. Less energy was consumed to attain a given fines level by using the endoglucanase enzymes. The DP and viscosity were also decreased using the enzymes. The morphological properties of the enzyme-pretreated spray-dried CNF powders (SDCNFs) were measured. Subsequently, the enzyme-pretreated SDCNFs were added to a PP matrix with MAPP as a coupling agent. The mixture was then compounded through a co-rotating twin-screw extruder to determine whether the enzyme treatment of the CNFs affects the mechanical properties of the composites. Compared to earlier studies on enhancing PMCs with SDCNF powders, this research investigates the use of enzyme-pretreated SDCNF powders. It was confirmed that the strength properties of PP increased by adding SDCNFs, and the strength properties were maintained after adding enzyme-pretreated SDCNFs.

59 BASIC BIOLOGICAL SCIENCES↗

Severity of liver disease affects HCV kinetics in patients treated with intravenous silibinin monotherapy

HCV kinetic analysis and modeling during antiviral therapy have not been performed in decompensated cirrhotic patients awaiting liver transplantation. Here, viral and host parameters were compared in patients treated with daily intravenous silibinin (SIL) monotherapy for 7 days according to the severity of their liver disease. Data were obtained from 25 patients, 12 non-cirrhotic, 8 with compensated cirrhosis and 5 with decompensated cirrhosis. The standard-biphasic model with time-varying SIL effectiveness (from 0 to ε max ) was fit to viral kinetic data. Our results show that baseline viral load and age were significantly associated with the severity of liver disease (p<0.0001). A biphasic viral decline was observed in most patients with a higher first phase decline patients with less severe liver disease. The maximal effectiveness, ε max , was significantly (p≤0.032) associated with increasing severity of liver disease (ε max [s.e.]=0.86[0.05], ε max =0.69[0.06] and ε max =0.59[0.1]). The 2nd phase decline slope was not significantly different among groups (mean 1.88±0.15 log 10 IU/ml/wk, p=0.75) as was the rate of change of SIL effectiveness (k=2.12/day[standard error, SE=0.18/day]). HCV-infected cell loss rate (δ[SE]=0.62/day[0.05/day]) was high and similar among groups. We conclude that the high loss rate of HCV-infected cells suggests that sufficient dose and duration of SIL might achieve viral suppression in advanced liver disease.

59 BASIC BIOLOGICAL SCIENCES↗